Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
2
3
NO
TE
SC
OM
PO
NE
NT
CO
DE
SW
IRE
CO
LO
R C
OD
EBK......BLACK
BR......BROWN
BL.......BLUE
G........GREEN
GY
......GRAYO........ORANGE
PR......PURPLER........REDW
.......WHITE
Y........YELLOW
WIR
ING
INFO
RM
AT
ION
WARNING
-CABINET MUST BE PERMANENTLY GROUNDED
AND CONFORM TO I.E.C., N.E.C., C.E.C.,
NATIONAL WIRING REG
ULATIONS, AND LOCALCODES A
S APPLICABLE.
REPLACEMENT W
IRE-M
UST BE THE SAME SIZE AND TYPE
OF INSULATION AS ORIGINAL (105ºC MIN.)
-FIELD INSTALLED
-FACTORY STANDARDLOW
VOLTAGE-FIELD INSTALLED-FACTORY OPTION-FACTORY STANDARDLINE VOLTAGE
-FACTORY OPTION
ORIGINAL RELEASENO.:
ELE
CT
RIC
AL W
IRIN
G D
IAG
RA
M
MODELED
BY:
CHECKED:APPROVED:
REV:PART NO.:
DATE:
1.2.3.4.5.6.7. CONNECTORS SUITABLE FOR USE WITH COPPER CONDUCTORS ONLY.CONNECT FIELD WIRING IN GROUNDED RAIN TIGHT CONDUIT TO FUSED DISCONNECT.CONNECT FIELD WIRE TO COMPRESSOR CONTACTOR (CC1).REMOVE J3 AT (CC1) TO INSTALL LOW AMBIENT ACCESSORY.IF REQUIRED, ATTACH CRANKCASE HEATER ACCESSORY TO CC1 (L1) AND CC1 (L2).COMPRESSOR MOTOR THERMALLY PROTECTED. ALL 3 PHASE MODELS AREPROTECTED UNDER PRIMARY SINGLE PHASE CONDITIONS.TRANSFORMER FACTORY WIRED AS SHOWN BELOW. CHANGE PRIMARY VOLTAGECONNECTIONS FOR ALTERNATE VOLTAGES, IF REQUIRED.
UNIT VOLTAGES - HZ200-220 - 50HZ
208 - 60HZ230 - 60HZ380 - 60HZ
380-415 - 50HZ460 - 60HZ575 - 60HZ
8.9.10. LOW VOLTAGE CIRCUIT IS N.E.C. CLASS 2 WITH A
CLASS 2 TRANSFORMER, 24VAC, 50/60 HZ SUPPLIED.MOTOR FACTORY WIRED FOR CORRECT VOLTAGE.REMOVE PL36 FOR ECONOMIZER ACCESSORY.PL34 AND PL36 LOCATED IN RETURN AIR SECTION.
TRANSFORMER TERM.200230230400400460230
BCCACCCCHCDSCFS
COMPCTDAT
DISCFLMSFPFSGFCOGL
GNDHPCIBMIDMIFCLAC
BLOWER CONTACTORCOMFORT ALERT MODULECOMPRESSOR CONTACTORCRANKCASE HEATERCLOGGED DRAIN SENSORCLOGGED FILTER SWITCHCOMPRESSORCONTROL TRANSFORMERDISCHARGE AIR SENSORDISCONNECT SWITCHFLAME SENSORFAN PROVINGFREEZE SENSORGROUND FAULT CONVENIENCE OUTLETGROUND LUGGROUNDHIGH PRESSURE CONTROLINDOOR BLOWER MOTORINDUCED DRAFT MOTORINTEGRATED FURNACE CONTROLLOW AMBIENT CONTROL
LPCMASMLC
MRLCNPCOAT
OFMPLPTRATRC
RTU-CSE
LOW PRESSURE CONTROLMIXED AIR SENSORMAIN LIMIT CONTROLMANUAL RESET LIMIT CONTROLNEGATIVE PRESSURE SWITCHOUTSIDE AIR SENSOROUTDOOR FAN MOTORPLUGPOWER TRANSFORMERRETURN AIR SENSORRUN CAPACITORROOFTOP UNIT CONTROLSPARK ELECTRODEWIRE NUT
WIRE TIE##
90-106177-0100
GE NON DDC 1 STG 090/102/120208/230/380/460V, 3PH, 60HZ
GE NON DDC 1 STG 072/090/102380-415V, 3PH, 50HZ
TEW10-17-17
R-1071S089
SE
GN
D
109PR
106R/W PR
105
NPC
MRLC
103Y
104 Y
101O
102O
MLC
IDM002
BK004
BK
HPC
BLHIGV2C
203BR202
W/BK
204MPGV1
FLMS
201 R
89
76
54
12
3
10
CO
NT
RO
L B
OX
CO
NT
RO
L B
OX
47BR
RC 2
46
O
45 BR
RC 1
44O
43BK
OFM 2
T1T2
T3
42BK
OFM 1
T1T2
T3
LPCLACOPT.
DISCONNECTSW
ITCH(OPTIONAL)
L1L2
L3
1T1
BK
1T3 R
1T2
PR
COMP 1 T1
T2
T3
T1T2
T3
L1L2
L3A2 CC1
A1
BK1T1 PR1T2 R
1T3
T1T2
T3Y2
Y1L
RC
PDC
T1T2
T3
L1L2
L3A2
BC A1
BK176
R159
TO LINE VOLTAGE
CA1 (OPT)
BR/W12
11BK
3T2
BK
3T3
606
BR
GY
601
O
BK
BK
BK
BK
BKBK
BK
O
BK
3T1COM
PRESSOR WIRES
WILL ALL BE BK ON
120 BTUH MODELS
45
12
3
6
PL 1921
21
YY
GFCO(OPTIONAL)
RESET(-)
(+)
J3Y
Y
PL 21
21
21 Y
Y
707
BR
162Y
O
1234
1234
PL-44T1
T2T3
IBM BD
GND
3T13T23T3
BKBK BKG
9
PL-2PL-1
BKBK
BK
RBL
PRBR
704703Y
Y
706705
YY
21
PL 2321
VV
FSOPT.
K6 1218-11062-106860-05
K7K8P6
OCCCC2CK5K4
CC2CC1
P4
P7C CC
24VACSDREM
P3
RG
Y1Y2
CW
1W
2L
P1
P2
K1K2
K3
K13
K12
CDSIND1
K10L1
HEATH/CL1
L1
COOLPARK
IFC
L3
PL-6
123456789101112131415
123456789101112
21
123456789101112
OYR
314312
311
308
BKBK
315
PR/WBL
307BR
PR/WGY
YO
305
301R/W
R
BK
302
PL-3
PL-7
162Y
BR178
R177
707706
705704
703702
701
BR
Y YYY
BKBK
606BR
601GY
PL-4(OPT)
PL-4
R/G088
BKBKRR
174
159
173176
BR178
R177
BK173
R174
7
315BK
BK314
PL-35MAS
PL-34PL-36301
BR305
GY308
R/W
312PR/W
302307 311
RPR/WBL
PL 2321
21
YYVV
CDSJ4
R/G088
7654321
87654321
C24
LINE
LOADC
CT
8
10
3T13T2
3T3
702701
BKBK
4
CD
S
O
BR 47
46
O 44
45 BR
OFM
2
BK 43
OFM
1
BK 42
MAS
21
LPC
LACO
PT
IBM BD
GG
ND
3T1
3T23T3
BKBKBK
HPC
PL 23FS
OPT.
A1
A2
1T1
RPR
BK
RPR
BK
1T2
1T3
C
LINE
LOAD
24C
CT
A1A2
BR178
BR
R177
R177
R174
R174
BK173
BK173
162
162
R/G
088
088R
/G
PU
TO LIN
E VO
LTAGE Y
Y178
CC
1CCCC
P5
P4
CC
2
CC
2C
OC
C
1218-300K6
K747-102884-02
K8P13
P14
P6K5
K4
P7
SD
REM
RR
3 2 1
RG
Y1Y2
CW
1W
2W
3B
L
PL1
P11
P8
W1
B W3
P1P2 D R
VR
V
P16
TESTK3
PL15
80706050
FI 24VACC
DS
OAT
OC
T
PL3
12
34
56
PL3 123456
P51
23
45
PR BLR
BRBR
/W
1T1 1T2 1T3
T1T2
T3Y2
Y1L
RC
PD
C
T1T2
T3
L1L2
L3C
C1
L1L2
L3 T3T2
T1
T2T1T3
PL 4(O
PT)
CA1 (O
PT)
RC
1R
C2
1 2
12
34
5
J3
PL 441234PL 23
PL 21
1122
PL 19
J4
PL-3 123456789101112131415
123456789101112
PL-34
PL-3521
123456789101112
PL-36
R
Y O
1 221
P41 2 3 4 5 6 7
1 2 3 4 5 6 7 8
22
11
12
34
5
1234
BK
3T1BK
3T13T2
3T2BK
BKBK
3T3BK
3T3
707
707BR
706Y
706Y
705Y
YY
701BK
606
606BR
601
GY
601
315BK
315BK
312PR
/W
312PR
/W
BR
308BR
PR/W
PR/W
307
R/W
301R
/W
O
BK
BKBK
BK
BKBK
BK
O
O
Y
BK
GY
O
705Y
703
Y
GY
BR
BR
704703702
BK701
BK
301302305
307308
311
314
702BK
BK
314BK
305G
Y
311BL
302R
R
BL
Y704
101BR102
PR103R
104BK
105BL
45
12
3
6
78
10
9
11 12C
ON
TRO
L BOX
CO
NTR
OL BO
X
WIRE CO
LOR CO
DEBK......BLACKBR......BROW
NBL.......BLUE
G........GREENGY......GRAYO........ORANGE
PR......PURPLER........REDW
.......WHITE
Y........YELLOW
ORIGINAL RELEASENO.:
ELECTRICAL WIRING DIAGRAM
MODELED
BY:
CHECKED:APPROVED:
REV:PART NO.:
DATE:
NOTESCONNECTORS SUITABLE FOR USE W
ITH COPPER CONDUCTORS ONLY.
CONNECT FIELD WIRING IN GROUNDED RAIN TIGHT CONDUIT TO FUSED DISCONNECT.
CONNECT FIELD WIRE TO COM
PRESSOR CONTACTOR (CC1).
REMOVE J3 AT (CC1) TO INSTALL LOW
AMBIENT ACCESSORY.
IF REQUIRED, ATTACH CRANKCASE HEATER ACCESSORY TO CC1 (L1) AND CC1 (L2).
COMPRESSOR M
OTOR THERMALLY PROTECTED. ALL 3 PHASE M
ODELS ARE PROTECTED UNDER PRIM
ARY SINGLE PHASE CONDITIONS.
TRANSFORMER FACTORY W
IRED AS SHOWN BELOW
. CHANGE PRIMARY VOLTAGE
CONNECTIONFOR ALTERNATE VOLTAGES, IF REQUIRED.
UNIT VOLTAGES –HZ TRANSFORMER TERM
.200-220 –50 HZ
200
208 –60 HZ
230230 –60 HZ
230
380 –60 HZ
400380-414 -50 HZ
400
460 –60 HZ
460575 –60 HZ
575
LOW VOLTAGE CIRCUIT IS N.E.C. CLASS 2 W
ITH A CLASS 2 TRANSFORMER, 24VAC 50/60
HZ SUPPLIED.
MOTOR FACTORY W
IRED FOR CORRECT VOLTAGE.
REMOVE PL23 JUM
PER FOR OPTIONAL FT LOCATED IN BLOWER COM
PARTMENT.
REMOVE PL36 FOR ECONOM
IZER ACCESSORY. PL34 AND PL36 LOCATED IN RETURN AIR SECTION.
MAS ACCESSORY PROVIDED W
ITH ECONOMIZER. PL35 LOCATED IN BLOW
ER COM
PARTMENT.
1.2.3.4.5.6.7.
8.9.10.
11.
12.
##
COMPONENT CODES
BCCACCCCHCDSCFSCOM
PCTDATDISCFLM
SFPFSGFCOGLGNDHPCIBM
BDIDMIFCJ
BLOWER CONTACTOR
COMFORT ALERT M
ODULECOM
PRESSOR CONTACTORCRANKCASE HEATERCLOGGED DRAIN SENSORCLOGGED FILTER SW
ITCHCOM
PRESSORCONTROL TRANSFORM
ERDISCHARGE AIR SENSORDISCONNECT SW
ITCHFLAM
E SENSORFAN PROVINGFREEZE SENSORGROUND FAULT CONVENIENCE OUTLETGROUND LUGGROUNDHIGH PRESSURE CONTROLINDOOR BLOW
ER MOTOR BELT DRIVE
INDUCED DRAFT MOTOR
INTEGRATED FURNACE CONTROLJUM
PER
LOW AM
BIENT CONTROLLOW
PRESSURE CONTROLM
ANUAL RESET LIMIT CONTROL
NEGATIVE PRESSURE SWITCH
OUTSIDE AIR SENSOROUTDOOR FAN M
OTORPLUGPOW
ER TRANSFORMER
RETURN AIR SENSORRUN CAPACITIORROOTOP UNIT CONTROLSPARK ELECTRODEW
IRE NUT
WIRE TIES
LACLPCM
RLCNPCOATOFMPLPTRATRCRTU-CSE
WIRING INFORM
ATION
WARNING
-CABINETMUSTBE PERMANENTLYGROUNDED
ANDCONFORM
TOI.E.C.,N.E.C.,C.E.C.,
NATIONALW
IRINGREGULATIONS, AND
LOCALCODES AS APPLICABLE
REPLACEMENT
WIRE
-MUST
BETHE
SAME
SIZEAND
TYPEOF INSULATION
ASORIGINAL(105C.M
IN.)
-FIELDINSTALLED
-FACTORYSTANDARD
LOWVOLTAGE
-FIELDINSTALLED
-FACTORYOPTION
-FACTORYSTANDARD
LINEVOLTAGE
-FACTORYOPTION
AC
NO
N D
DC
1-STG
, 090,102 & 120
208/230/380/460/575V, 3PH
60 Hz.
AC
NO
N D
DC
1-STG
072/090/102380-415V
3PH
50Hz.
JHB
8/21/17
90-106177-2100
R-1071S
089
BK
ON
120 BTU
H
MO
DE
LS
5
6
7
CM 11178