8

92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm
Page 2: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

2

Page 3: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

3

Page 4: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

NO

TE

SC

OM

PO

NE

NT

CO

DE

SW

IRE

CO

LO

R C

OD

EBK......BLACK

BR......BROWN

BL.......BLUE

G........GREEN

GY

......GRAYO........ORANGE

PR......PURPLER........REDW

.......WHITE

Y........YELLOW

WIR

ING

INFO

RM

AT

ION

WARNING

-CABINET MUST BE PERMANENTLY GROUNDED

AND CONFORM TO I.E.C., N.E.C., C.E.C.,

NATIONAL WIRING REG

ULATIONS, AND LOCALCODES A

S APPLICABLE.

REPLACEMENT W

IRE-M

UST BE THE SAME SIZE AND TYPE

OF INSULATION AS ORIGINAL (105ºC MIN.)

-FIELD INSTALLED

-FACTORY STANDARDLOW

VOLTAGE-FIELD INSTALLED-FACTORY OPTION-FACTORY STANDARDLINE VOLTAGE

-FACTORY OPTION

ORIGINAL RELEASENO.:

ELE

CT

RIC

AL W

IRIN

G D

IAG

RA

M

MODELED

BY:

CHECKED:APPROVED:

REV:PART NO.:

DATE:

1.2.3.4.5.6.7. CONNECTORS SUITABLE FOR USE WITH COPPER CONDUCTORS ONLY.CONNECT FIELD WIRING IN GROUNDED RAIN TIGHT CONDUIT TO FUSED DISCONNECT.CONNECT FIELD WIRE TO COMPRESSOR CONTACTOR (CC1).REMOVE J3 AT (CC1) TO INSTALL LOW AMBIENT ACCESSORY.IF REQUIRED, ATTACH CRANKCASE HEATER ACCESSORY TO CC1 (L1) AND CC1 (L2).COMPRESSOR MOTOR THERMALLY PROTECTED. ALL 3 PHASE MODELS AREPROTECTED UNDER PRIMARY SINGLE PHASE CONDITIONS.TRANSFORMER FACTORY WIRED AS SHOWN BELOW. CHANGE PRIMARY VOLTAGECONNECTIONS FOR ALTERNATE VOLTAGES, IF REQUIRED.

UNIT VOLTAGES - HZ200-220 - 50HZ

208 - 60HZ230 - 60HZ380 - 60HZ

380-415 - 50HZ460 - 60HZ575 - 60HZ

8.9.10. LOW VOLTAGE CIRCUIT IS N.E.C. CLASS 2 WITH A

CLASS 2 TRANSFORMER, 24VAC, 50/60 HZ SUPPLIED.MOTOR FACTORY WIRED FOR CORRECT VOLTAGE.REMOVE PL36 FOR ECONOMIZER ACCESSORY.PL34 AND PL36 LOCATED IN RETURN AIR SECTION.

TRANSFORMER TERM.200230230400400460230

BCCACCCCHCDSCFS

COMPCTDAT

DISCFLMSFPFSGFCOGL

GNDHPCIBMIDMIFCLAC

BLOWER CONTACTORCOMFORT ALERT MODULECOMPRESSOR CONTACTORCRANKCASE HEATERCLOGGED DRAIN SENSORCLOGGED FILTER SWITCHCOMPRESSORCONTROL TRANSFORMERDISCHARGE AIR SENSORDISCONNECT SWITCHFLAME SENSORFAN PROVINGFREEZE SENSORGROUND FAULT CONVENIENCE OUTLETGROUND LUGGROUNDHIGH PRESSURE CONTROLINDOOR BLOWER MOTORINDUCED DRAFT MOTORINTEGRATED FURNACE CONTROLLOW AMBIENT CONTROL

LPCMASMLC

MRLCNPCOAT

OFMPLPTRATRC

RTU-CSE

LOW PRESSURE CONTROLMIXED AIR SENSORMAIN LIMIT CONTROLMANUAL RESET LIMIT CONTROLNEGATIVE PRESSURE SWITCHOUTSIDE AIR SENSOROUTDOOR FAN MOTORPLUGPOWER TRANSFORMERRETURN AIR SENSORRUN CAPACITORROOFTOP UNIT CONTROLSPARK ELECTRODEWIRE NUT

WIRE TIE##

90-106177-0100

GE NON DDC 1 STG 090/102/120208/230/380/460V, 3PH, 60HZ

GE NON DDC 1 STG 072/090/102380-415V, 3PH, 50HZ

TEW10-17-17

R-1071S089

SE

GN

D

109PR

106R/W PR

105

NPC

MRLC

103Y

104 Y

101O

102O

MLC

IDM002

BK004

BK

HPC

BLHIGV2C

203BR202

W/BK

204MPGV1

FLMS

201 R

89

76

54

12

3

10

CO

NT

RO

L B

OX

CO

NT

RO

L B

OX

47BR

RC 2

46

O

45 BR

RC 1

44O

43BK

OFM 2

T1T2

T3

42BK

OFM 1

T1T2

T3

LPCLACOPT.

DISCONNECTSW

ITCH(OPTIONAL)

L1L2

L3

1T1

BK

1T3 R

1T2

PR

COMP 1 T1

T2

T3

T1T2

T3

L1L2

L3A2 CC1

A1

BK1T1 PR1T2 R

1T3

T1T2

T3Y2

Y1L

RC

PDC

T1T2

T3

L1L2

L3A2

BC A1

BK176

R159

TO LINE VOLTAGE

CA1 (OPT)

BR/W12

11BK

3T2

BK

3T3

606

BR

GY

601

O

BK

BK

BK

BK

BKBK

BK

O

BK

3T1COM

PRESSOR WIRES

WILL ALL BE BK ON

120 BTUH MODELS

45

12

3

6

PL 1921

21

YY

GFCO(OPTIONAL)

RESET(-)

(+)

J3Y

Y

PL 21

21

21 Y

Y

707

BR

162Y

O

1234

1234

PL-44T1

T2T3

IBM BD

GND

3T13T23T3

BKBK BKG

9

PL-2PL-1

BKBK

BK

RBL

PRBR

704703Y

Y

706705

YY

21

PL 2321

VV

FSOPT.

K6 1218-11062-106860-05

K7K8P6

OCCCC2CK5K4

CC2CC1

P4

P7C CC

24VACSDREM

P3

RG

Y1Y2

CW

1W

2L

P1

P2

K1K2

K3

K13

K12

CDSIND1

K10L1

HEATH/CL1

L1

COOLPARK

IFC

L3

PL-6

123456789101112131415

123456789101112

21

123456789101112

OYR

314312

311

308

BKBK

315

PR/WBL

307BR

PR/WGY

YO

305

301R/W

R

BK

302

PL-3

PL-7

162Y

BR178

R177

707706

705704

703702

701

BR

Y YYY

BKBK

606BR

601GY

PL-4(OPT)

PL-4

R/G088

BKBKRR

174

159

173176

BR178

R177

BK173

R174

7

315BK

BK314

PL-35MAS

PL-34PL-36301

BR305

GY308

R/W

312PR/W

302307 311

RPR/WBL

PL 2321

21

YYVV

CDSJ4

R/G088

7654321

87654321

C24

LINE

LOADC

CT

8

10

3T13T2

3T3

702701

BKBK

4

Page 5: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

CD

S

O

BR 47

46

O 44

45 BR

OFM

2

BK 43

OFM

1

BK 42

MAS

21

LPC

LACO

PT

IBM BD

GG

ND

3T1

3T23T3

BKBKBK

HPC

PL 23FS

OPT.

A1

A2

1T1

RPR

BK

RPR

BK

1T2

1T3

C

LINE

LOAD

24C

CT

A1A2

BR178

BR

R177

R177

R174

R174

BK173

BK173

162

162

R/G

088

088R

/G

PU

TO LIN

E VO

LTAGE Y

Y178

CC

1CCCC

P5

P4

CC

2

CC

2C

OC

C

1218-300K6

K747-102884-02

K8P13

P14

P6K5

K4

P7

SD

REM

RR

3 2 1

RG

Y1Y2

CW

1W

2W

3B

L

PL1

P11

P8

W1

B W3

P1P2 D R

VR

V

P16

TESTK3

PL15

80706050

FI 24VACC

DS

OAT

OC

T

PL3

12

34

56

PL3 123456

P51

23

45

PR BLR

BRBR

/W

1T1 1T2 1T3

T1T2

T3Y2

Y1L

RC

PD

C

T1T2

T3

L1L2

L3C

C1

L1L2

L3 T3T2

T1

T2T1T3

PL 4(O

PT)

CA1 (O

PT)

RC

1R

C2

1 2

12

34

5

J3

PL 441234PL 23

PL 21

1122

PL 19

J4

PL-3 123456789101112131415

123456789101112

PL-34

PL-3521

123456789101112

PL-36

R

Y O

1 221

P41 2 3 4 5 6 7

1 2 3 4 5 6 7 8

22

11

12

34

5

1234

BK

3T1BK

3T13T2

3T2BK

BKBK

3T3BK

3T3

707

707BR

706Y

706Y

705Y

YY

701BK

606

606BR

601

GY

601

315BK

315BK

312PR

/W

312PR

/W

BR

308BR

PR/W

PR/W

307

R/W

301R

/W

O

BK

BKBK

BK

BKBK

BK

O

O

Y

BK

GY

O

705Y

703

Y

GY

BR

BR

704703702

BK701

BK

301302305

307308

311

314

702BK

BK

314BK

305G

Y

311BL

302R

R

BL

Y704

101BR102

PR103R

104BK

105BL

45

12

3

6

78

10

9

11 12C

ON

TRO

L BOX

CO

NTR

OL BO

X

WIRE CO

LOR CO

DEBK......BLACKBR......BROW

NBL.......BLUE

G........GREENGY......GRAYO........ORANGE

PR......PURPLER........REDW

.......WHITE

Y........YELLOW

ORIGINAL RELEASENO.:

ELECTRICAL WIRING DIAGRAM

MODELED

BY:

CHECKED:APPROVED:

REV:PART NO.:

DATE:

NOTESCONNECTORS SUITABLE FOR USE W

ITH COPPER CONDUCTORS ONLY.

CONNECT FIELD WIRING IN GROUNDED RAIN TIGHT CONDUIT TO FUSED DISCONNECT.

CONNECT FIELD WIRE TO COM

PRESSOR CONTACTOR (CC1).

REMOVE J3 AT (CC1) TO INSTALL LOW

AMBIENT ACCESSORY.

IF REQUIRED, ATTACH CRANKCASE HEATER ACCESSORY TO CC1 (L1) AND CC1 (L2).

COMPRESSOR M

OTOR THERMALLY PROTECTED. ALL 3 PHASE M

ODELS ARE PROTECTED UNDER PRIM

ARY SINGLE PHASE CONDITIONS.

TRANSFORMER FACTORY W

IRED AS SHOWN BELOW

. CHANGE PRIMARY VOLTAGE

CONNECTIONFOR ALTERNATE VOLTAGES, IF REQUIRED.

UNIT VOLTAGES –HZ TRANSFORMER TERM

.200-220 –50 HZ

200

208 –60 HZ

230230 –60 HZ

230

380 –60 HZ

400380-414 -50 HZ

400

460 –60 HZ

460575 –60 HZ

575

LOW VOLTAGE CIRCUIT IS N.E.C. CLASS 2 W

ITH A CLASS 2 TRANSFORMER, 24VAC 50/60

HZ SUPPLIED.

MOTOR FACTORY W

IRED FOR CORRECT VOLTAGE.

REMOVE PL23 JUM

PER FOR OPTIONAL FT LOCATED IN BLOWER COM

PARTMENT.

REMOVE PL36 FOR ECONOM

IZER ACCESSORY. PL34 AND PL36 LOCATED IN RETURN AIR SECTION.

MAS ACCESSORY PROVIDED W

ITH ECONOMIZER. PL35 LOCATED IN BLOW

ER COM

PARTMENT.

1.2.3.4.5.6.7.

8.9.10.

11.

12.

##

COMPONENT CODES

BCCACCCCHCDSCFSCOM

PCTDATDISCFLM

SFPFSGFCOGLGNDHPCIBM

BDIDMIFCJ

BLOWER CONTACTOR

COMFORT ALERT M

ODULECOM

PRESSOR CONTACTORCRANKCASE HEATERCLOGGED DRAIN SENSORCLOGGED FILTER SW

ITCHCOM

PRESSORCONTROL TRANSFORM

ERDISCHARGE AIR SENSORDISCONNECT SW

ITCHFLAM

E SENSORFAN PROVINGFREEZE SENSORGROUND FAULT CONVENIENCE OUTLETGROUND LUGGROUNDHIGH PRESSURE CONTROLINDOOR BLOW

ER MOTOR BELT DRIVE

INDUCED DRAFT MOTOR

INTEGRATED FURNACE CONTROLJUM

PER

LOW AM

BIENT CONTROLLOW

PRESSURE CONTROLM

ANUAL RESET LIMIT CONTROL

NEGATIVE PRESSURE SWITCH

OUTSIDE AIR SENSOROUTDOOR FAN M

OTORPLUGPOW

ER TRANSFORMER

RETURN AIR SENSORRUN CAPACITIORROOTOP UNIT CONTROLSPARK ELECTRODEW

IRE NUT

WIRE TIES

LACLPCM

RLCNPCOATOFMPLPTRATRCRTU-CSE

WIRING INFORM

ATION

WARNING

-CABINETMUSTBE PERMANENTLYGROUNDED

ANDCONFORM

TOI.E.C.,N.E.C.,C.E.C.,

NATIONALW

IRINGREGULATIONS, AND

LOCALCODES AS APPLICABLE

REPLACEMENT

WIRE

-MUST

BETHE

SAME

SIZEAND

TYPEOF INSULATION

ASORIGINAL(105C.M

IN.)

-FIELDINSTALLED

-FACTORYSTANDARD

LOWVOLTAGE

-FIELDINSTALLED

-FACTORYOPTION

-FACTORYSTANDARD

LINEVOLTAGE

-FACTORYOPTION

AC

NO

N D

DC

1-STG

, 090,102 & 120

208/230/380/460/575V, 3PH

60 Hz.

AC

NO

N D

DC

1-STG

072/090/102380-415V

3PH

50Hz.

JHB

8/21/17

90-106177-2100

R-1071S

089

BK

ON

120 BTU

H

MO

DE

LS

5

Page 6: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

6

Page 7: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

7

Page 8: 92-42556-08 Rev. 00 RXRX-AZ02 Comfort Alert Kit for NON ...pts.myrheem.com/docstore/webdocs/Public/Service...cds o br 47 46 o 44 45 br ofm 2 bk 43 ofm 1 bk 42 mas 2 1 lpc lac opt ibm

CM 11178