31
The Lab-Line series of environmental chambers provides the most complete selection available, ranging from bench top chambers to custom-sized walk-in units. Lab-Line is one of the first manufacturers to offer chambers specifically designed for the testing of drugs and drug substances for the FDA. In addition, we feature a complete line of refrigerated Ambi Hi-Lo ® chambers for B.O.D. and shelf life testing. For educational and research laboratories, see our complete line of classroom and research-grade plant growth chambers—available in sizes from reach-in to walk-in. Whatever the application, Lab-Line has an Environmental Chambers— Bench Top Environ-Cab Humidity Chambers 3–5 Reach-in Environette Chambers .......... 6–9 Walk-in Environette Chambers .......... 10–11 Custom “EC” Walk-in Environmental Chambers 12 V.I.P. Walk-in Chambers ............... 13–16 Walk-in Frigid Chambers ............... 17–18 Ambi Hi-Lo Chambers .................. 19–20 Biotronette Mark II Plant Growth Incubators 21 Plant Growth Chambers ................ 22 Large Capacity Plant Growth Chambers .... 23 Custom Walk-in Plant Growth Chambers . . . 24 Educational Chambers .................. 25 Educational Chambers Ambi Hi-Lo Chamber Reach-In Environette Chamber

960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

The Lab-Line series of environmental chambers provides the most completeselection available, ranging from bench top chambers to custom-sized walk-inunits. Lab-Line is one of the first manufacturers to offer chambers specificallydesigned for the testing of drugs and drug substances for the FDA. In addition,we feature a complete line of refrigerated Ambi Hi-Lo ® chambers for B.O.D. andshelf life testing. For educational and research laboratories, see our completeline of classroom and research-grade plant growth chambers—available in sizesfrom reach-in to walk-in. Whatever the application, Lab-Line has an

Environmental Chambers—Bench Top Environ-Cab Humidity Chambers 3–5Reach-in Environette Chambers . . . . . . . . . . 6–9Walk-in Environette Chambers . . . . . . . . . .10–11Custom “EC” Walk-in Environmental Chambers1 2V.I.P. Walk-in Chambers . . . . . . . . . . . . . . .13–16Walk-in Frigid Chambers . . . . . . . . . . . . . . .

17–18Ambi Hi-Lo Chambers . . . . . . . . . . . . . . . . . .19–20Biotronette Mark II Plant Growth Incubators2 1Plant Growth Chambers . . . . . . . . . . . . . . . . 2 2Large Capacity Plant Growth Chambers . . . . 2 3Custom Walk-in Plant Growth Chambers . . . 2 4Educational Chambers . . . . . . . . . . . . . . . . . . 2 5

Educational Chambers

Ambi Hi-Lo Chamber

Reach-In Environette Chamber

Page 2: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• Compact size conservesvaluable lab space

• Precise microprocessor-based P.I.D. control oftemperature and humidity

• Environmentally safe CFC-free foam insulation

• CE certified

• 12 month warranty

Model 685

Control Panel

Environ-Cab ® Series

Lab-Line’s Environ-Cab series of chambers is designedto provide accurate environmental control oftemperature and humidity. These models are ideal foruse in research and development applications such asphotolysis tests, shelf life tests, and packaging, paper products, or electroniccomponent breakdown. Additionally, all models conform to FDA requirements for drug stability testing.

♦ Two sizes—6.2 cu. ft. or 10.4 cu. ft.

♦ Temperature accuracy and uniformity of ±0.5°C

♦ Color-coded digital displays for visual ease

♦ Inner glass viewing door

♦ Ideal for ICH/FDA drug stability tests

Model 680

Page 3: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

100

90

80

70

60

50

40

30

20

10

05 10 15 20 25 30 35 40 45 50 55 60

TEMPERATURE/HUMIDITY PERFORMANCE CHART%R.H.

°C

Upper limit of humidification by spray nozzle(standard on 680 series)

Lower limit of Dehumidification by Refrigeration(Option D)

HumidificationDehumidification by Refrigeration

680 Series Options

♦ Dehumidification by Refrigeration (D)—An additionalcoil in the refrigeration system works with thespray nozzles to accurately maintain humidity at orbelow ambient conditions. ( Note: Only available forrefrigerated models 680A, 680A-1, 685A, 685A-1.)

♦ Deionizer cartridge assembly (I) —Clean water isessential to long-term operation of humiditychambers. Where deionized water is not available,the deionizer cartridge can be added. While thiscartridge will provide adequate filtering for manyapplications, a local water quality analysis should beperformed to determine whether more extensivepurification is required.

♦ Chart Recorder (R4) —For creating a permanentrecord of temperature and humidity data, a two-pen,10 inch, 7-day recorder can be provided. A

programmable chart recorder giving the user choiceof T/RH ranges and time span for charts is alsoavailable—contact Lab-Line for details.

♦ Computer Communications Port (C1, C2) — R S 2 3 2communications ports can be provided fortemperature only (C1) or temperature and humidity(C2) for applications where data needs to be loggedinto a database.

♦ Fluorescent Lighting (F)—A lighting packageconsisting of four 14 watt fluorescent bulbs can bemounted under a support shelf in the top of thechamber. ( Note: When the lighting option is ordered,only one shelf will be provided.)

♦ Programmable Microprocessor (M)—A 24 stepprogrammable microprocessor is available, capableof four programs containing six steps each.

This chart shows the range of set points achievable in the 680A, 680A-1, 685A, and 685A-1 with the addition ofOption D—Dehumidification by Refrigeration. To use the chart, locate desired temperature along the bottom axis andfollow that line up until it crosses the red Option D line. This is the lower humidity limit.The point where the temperatureline crosses the green humidification line is the upper humidity limit. Contact Lab-Line for additional informationregarding temperature and humidity set points.

Page 4: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPTIONS

D Dehumidification by Refrigeration* F Light Package: (4) Fluorescent tubes, Horizontal†

I Deionizer Cartridge Assembly M 24-step Programmable Microprocessor

R4 Chart Recorder, 2-pen, 7-day Temperature & Humidity T Temperature Timer 7-day

C1 RS232 Computer Port—Temperature only 680-8 Extra Shelf Models 680, 680-1, 680A, 680A-1

C2 RS232 Computer Port Temperature/Humidity 685-8 Extra Shelf Models 685, 685-1, 685A, 685A-1

*Limited by a 40°F dew point.†Only one shelf in chamber with light package

OPERATING SPECIFICATIONS

TemperatureTemp. Range Temp. Control Uniformity Humidity Humidity No of shelves &

Model (°C) (°C) (°C) Range Control Shelf area

680Amb. plus 10 to 60 2 shelves

680-1 2.25 sq.ft. (ea.)680A

5 to 60(2090 sq.cm.)

680A-1 ± 0.5 ± 0.5 Amb. plus 10% ±5%

685Amb. plus 10 to 60

to 95%*3 shelves

685-1 3.7 sq.ft. (ea.)685A

5 to 60(3437 sq.cm.)

685A-1

* Limited by 100°F dew point.

ORDERING INFORMATION

Chamber Vol. Chamber Dim. Exterior DIm. Net Weight Ship WeightPower Supply cu. ft. W" x D" x H" W" x D" x H" lbs. lbs.

Model volts/ph/Hz Watts (<) (cm) (cm) (kg) (kg)

680 120/1/60800 180 225

680-1 220/1/50 6.2 22 x 22 x 22 25 x 26 x 37.5 (81.8) (1023)

680A 120/1/601700

(176) (56 x 56 x 56) (22 x 22 x 22) 210 255680A-1 220/1/50 (95.3) (115.7)

685 120/1/60800 295 340

685-1 220/1/50 10.4 30 x 20 x 30 32.5 x 25.5 x 50.75 (134) (155)

685A 120/1/601700

(295) (76 x 51 x 76) (83 x 65 x 129) 325 370685A-1 220/1/50 (148) (168)

MODELS RECOMMENDED For Stability Testing of Drugs and Pharmaceuticals (ICH/FDA Guidelines)

LONG TERM TESTS

25°C ±2°C—60% RH ±5%

680A/680A-1 DR4685A/680A-1 DR4

ACCELERATED TESTS

40°C ±2°C—75% RH ±5%

680/680-1 R4685/685-1 R4

Page 5: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• Microprocessor-based maintemperature controller

• Digital temperature setwith LED readout

• Available in four sizes andtwo temperature ranges

• CFC free

• CE certified

• 12 month warranty

Environette ® Reach-Ins

These versatile chambers are designed to provideexacting control and uniformity across a wide variety of applications—including FDA drug stability testing,genetic studies, shelf life testing, chromatographytests, tissue culture studies, growth chamber studies,and many more.

♦ Four sizes—from 21 cu. ft. to 69 cu. ft.

♦ Two temperature ranges—10°C above ambient to60°C,

or 0°C to 60°C

♦ Temperature control and uniformity of ±0.5°C

♦ Zero-switching microprocessor-based maintemperature controller with multi-range auto tuningPID control for fast control response with minimalovershooting

♦ Sturdy 24 gauge galvanized steel exterior with greyenamel finish

Model 702

Control Panel

See page 104 –105for

Standard

Page 6: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

700 Series Options

♦ Stainless Steel Interior (S) —necessary for chamberswith controlled humidity.

♦ Humidification by Centrifugal Atomizer (H )—thestandard method for providing humidity. Atomizer islocated at top of chamber, sends heated vapor mistinto ceiling air plenum.

♦ Humidification by Steam Generator (G )—forapplications beyond the limits of the centrifugalatomizer, generator produces steam from a reservoirmounted on the side of the chamber.

♦ Dehumidification by Refrigeration (D)—additionalcoil in the refrigeration system maintains humidityat or below ambient conditions. (Note: A condensingunit must be added for non-refrigerated models.)

♦ Dehumidification by Chemical Dryer (CD )—forapplications beyond the limits of option D, a silica-

based dessicant bed dryer can be installed. The silicais regenerated by a heating system in the dryer,which must be vented to the building exhaust system.(Note: Consult Lab-Line regarding temperature andhumidity requirements for the application)

♦ Chart Recorder (R3, R4) —for creating a permanentrecord of temperature and humidity data, a one- or two-pen, 10 inch, 7-day recorder can be provided.

♦ Other Options:

Vapor proof duplex outlets (V)

Interior fluorescent lights (F)

Access ports (P)

Temperature and lighting timers (T, T1)

Remote alarm junction (W)

100

90

80

70

60

50

40

30

20

10

05 10 15 20 25 30 35 40 45 50 55 60

TEMPERATURE/HUMIDITY PERFORMANCE CHART%R.H.

°C

Upper limit of Humidification byCentrifugal Atomizer (Option H)

Humidification by SteamGenerator (Option G)

Dehumidification byChemical Dryer (Option CD)

Lower limit of Dehumidificationby Refrigeration (Option D)

Centrifugal Atomizer Steam GeneratorDehumidification by RefrigerationDehumidification by Chemical Dryer

This chart shows the temperature/humidity set points which can be achieved by the various humidification/dehumidificationoptions. To use the chart, locate the desired temperature set point along the horizontal axis, and the desired humidity setpoint along the vertical axis. Follow the line of the temperature set point upward until it intersects the humidity set point line.The area within which the intersection point falls indicates the optional equipment that is necessary to achieve it. For example,if the point falls within the area bounded by the lines for Options H and D, this equipment will be required.1 If the point fallswithin the area above the Option H line, Option G will be needed. If the point falls below the Option D line, a chemical dryer(Option CD) will be necessary.2 1Some set points may require only Option H. Contact Lab-Line for details.

2Options D or CD must be used with either Option H or Option G.

Page 7: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPERATING SPECIFICATIONS

Temperature Range700 thru 703-2 Ambient plus 10°C to 60°C

700A thru 703A-2 0°C to 60°C

Temperature Control All Models ±0.5°C

Temperature Uniformity All Models ±0.5°C

Humidification All Models Optional; consult humidity chart & options listing.

ORDERING INFORMATION

Volts/ Chamber Capacity Interior Dim. Exterior Dim.2 ShippingPhase/ Req’d. cu. ft. W" x D" x H" W" x D" x H" Weight

Model Hz1 Amps (<) (cm) (cm) lbs. (kg.)

700 120/1/60 20 380 (174)

700-1 220/1/60 20410 (186)

700-2 220/1/50 20 21.6 24 x 24 x 65 28 x 30 x 903⁄4

700A 120/1/60 30 (611.7) (61 x 61 x 165) (71 x 76 x 231) 450 (205)

700A-1 220/1/60 30480 (218)

700A-2 220/1/50 30

701 120/1/60 20 460 (209)

701-1 220/1/60 20490 (223)

701-2 220/1/50 20 43.3 48 x 24 x 65 52 x 30 x 903⁄4

701A 120/1/60 30 (1,226.1) (122 x 61 x 165) (132 x 76 x 231) 530 (241)

701A-1 220/1/60 30560 (225)

701A-2 220/1/50 30

702 120/1/60 20 415 (189)

702-1 220/1/60 20445 (202)

702-2 220/1/50 20 32.5 36 x 26 x 65 40 x 30 x 903⁄4

702A 120/1/60 30 (920.3) (91 x 66 x 165) (102 x 76 x 231) 525 (239)

702A-1 220/1/60 30555 (252)

702A-2 220/1/50 30

703 120/1/60 20 650 (295)

703-1 220/1/60 20680 (309)

703-2 220/1/50 20 69.4 71 x 26 x 65 78 x 30 x 903⁄4

703A 120/1/60 30 (1,965.2) (180 x 66 x 165) (198 x 76 x 231) 680 (309)

703A-1 220/1/60 30710 (323)

703A-2 220/1/50 301Other electrical requirements available upon request.2Allow 18" above unit for routine maintenance. See page 9 for actual outside dimensions.

OPTIONS AVAILABLE

S stainless steel interior T1 timer for lighting

H humidification by centrifugal atomizer1,2,3 F internal fluorescent light fixture

G humidification by steam generator1,2,3 P through-wall penetration (specify size when ordering)

D dehumidification by refrigeration2 W remote alarm junction

CD dehumidification by chemical dryer 2,4 R3 1-pen 10" (25cm) chart recorder

V vapor proof duplex outlet R4 2-pen 10" (25cm) chart recorder

T timer for temperature M microprocessor controller with ramping capability (see p.4)

1 Requires distilled water supply.2 See humidity chart on page 7 for options required at various humidity & temperature ranges.3 Stainless steel is required with humidity options.4 Additional floor space is required for the addition of chemical dryers.

Page 8: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

A

B

C

G

F

I

H

D

E

A

B

C

MODEL A B C D E F G H I

700 421⁄4" 332⁄3" 28" 372⁄3" 30" 903⁄4" 801⁄2" 781⁄4" 331⁄3"

701 711⁄4" 572⁄3" 52" 372⁄3" 30" 903⁄4" 801⁄2" 781⁄4" 331⁄3"

702 591⁄4" 452⁄3" 40" 372⁄3" 30" 903⁄4" 801⁄2" 781⁄4" 331⁄3"

703 971⁄4" 832⁄3" 78" 372⁄3" 30" 903⁄4" 801⁄2" 781⁄4" 331⁄3"

MODELS RECOMMENDED For Stability Testing of Drugs and Pharmaceuticals (ICH/FDA Guidelines)

LONG TERM TESTS

25°C ±2°C—60% RH ±5%

700A/700A-2 SDHR4701A/701A-2 SDHR4702A/702A-2 SDHR4703A/703A-2 SDHR4

Environmental Chambers with heat andrefrigeration

Required Options:

S = Stainless steel interiorD = Dehumidification by refrigerationH = Humidification by centrifugal atomizerR4 = Two pen, ten-inch chart recorder

ACCELERATED TESTS

40°C ±2°C—75% RH ±5%

700/700-2 SHR4701/701-2 SHR4702/702-2 SHR4703/703-2 SHR4

Environmental Chambers with heat only

Required Options:

S = Stainless steel interiorH = Humidification by centrifugal atomizerR4 = Two pen, ten-inch chart recorder

Model 701, 702 Model 701, 702, 703 Model 703

Page 9: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPERATING SPECIFICATIONS

Interior Dim. Exterior Dim. Shelf Area Shelf SpaceTemperature W x D x H W x D x H1 sq. ft. ft.

Model Range (m) (m) (m2) (m)

704 10°C Above Ambient to 60°C. 4'0" x 4'0" x 6'10" 4'6" x 4'6" x 7'11" 60 48704A 0°C to 60°C. (1.2 x 1.2 x 2.1) (1.4 x 1.4 x 2.4) (5.8) (14.6)

706 10°C Above Ambient to 60°C. 4'0" x 6'0" x 6'10" 4'6" x 6'6" x 7'11" 80 73706A 0°C to 60°C. (1.2 x 1.8 x 2.1) (1.4 x 2.0 x 2.4) (7.4) (22.3)

708 10°C Above Ambient to 60°C. 4'0" x 8'0" x 6'10" 4'6" x 8'6" x 7'11" 100 97708A 0°C to 60°C. (1.2 x 2.4 x 2.1) (1.4 x 2.6 x 2.4) (9.3) (29.6)

1Outside height does not include top mounted equipment. Allow 36" above height noted.

• Microprocessor-based maintemperature controller

• Ideal for FDA stability tests,B.O.D. testing, and shelf lifetesting

• Available in three sizes andtwo temperature ranges

• CE certified

• 12 month warranty

Environette ® Walk-In

The 700 Series walk-in chambers deliver temperatureand humidity control for a wide range of applications,including FDA drug stability testing and test samplestorage.

♦ Three chamber sizes—109, 164, and 218 cu. ft.

♦ Two temperature ranges—10°C above ambient to60°C, or 0°C to 60°C

Model 704

Model 704 panel

♦ Temperature control and uniformity of ±0.5°C

♦ Zero-switching microprocessor-based maintemperature controller with multi-range auto tuningPID control for fast control response with minimalovershooting

♦ Modular panel construction with 3" of foamed-in-place polyurethane insulation

See page 17 forFrigid Chambers

Page 10: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

ORDERING INFORMATION

Electrical Service Required Shipping WeightModel Volts/Phase/Hz. * Amps lbs. (kg.)

704 220/1/60 20 1200 (544)

704-2 220/1/50 20 1227 (557)

704A 220/1/60 30 1550 (703)

704A-2 220/1/50 30 1636 (742)

706 220/1/60 20 1740 (789)

706-2 220/1/50 20 1776 (806)

706A 220/1/60 30 2000 (907)

706A-2 220/1/50 30 2109 (957)

708 220/1/60 20 2200 (998)

708-2 220/1/50 20 2236 (1014)

708A 220/1/60 30 2500 (1134)

708A-2 220/1/50 30 2572 (1167)

*Other electrical requirements available upon request.If Turnkey (Field) installation is required, contact Lab-Line.

OPTIONS AVAILABLE

S stainless steel interior T1 timer for lighting

H humidification by centrifugal atomizer1,2,3 F internal fluorescent light fixture

G humidification by steam generator1,2,3 P through-wall penetration (specify size when ordering)

D dehumidification by refrigeration2 W remote alarm junction

CD dehumidification by chemical dryer 2,4 R3 1-pen 10" (25cm) chart recorder

V vapor proof duplex outlet R4 2-pen 10" (25cm) chart recorder

T timer for temperature M microprocessor controller with ramping capability (see p.4)

1Requires distilled water supply.2See humidity chart on p. 7 for options required at various humidity & temperature ranges.3Stainless steel is required with humidity options.4Additional floor space is required for the addition of chemical dryers.

R4—chart recorder option

G—steam generator option

Page 11: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

Custom EC Walk-Ins

Lab-Line’s standard product line is designed toaccommodate a wide variety of uses in educational,research, and industrial settings. But some applicationsmay require different specifications than are availablein the standard models. For these situations, Lab-Lineoffers the customized EC series of walk-in chambers.Custom EC chambers can be built to accommodate anysize or floor plan configuration required, with thespecific interior and exterior finishes and selectedequipment options that are needed for your particularapplication. Contact Lab-Line for more information onoptions and a price quotation.

Available Options Include:

♦ Controlled humidification/dehumidification

♦ Chart recorders

♦ Internal electrical outlets

♦ Access ports

♦ Personnel safety alarm

♦ Shelves

• Microprocessor-based maintemperature controller

• Positive pressure ceilingplenum

• Modular panel constructionwith 4" of foamed-in-placepolyurethane insulation

• Locking control panelprotects controls, improvessafety and repeatability

• 12 month warranty

♦ Internal or external entrance ramps

♦ Custom door sizes

♦ Special lighting applications

♦ Custom condensing unit requirements—hermetic,semihermetic, top mount, remote mount, air cooled,water cooled, outdoor

♦ Custom interior and exterior finishes: stucco-embossed galvanized steel, baked-on enamel,stainless steel

♦ Turnkey installation available

Custom EC Walk-In Chamber

Custom EC Console

Page 12: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• Microprocessor-based maintemperature controller

• Separate Hi-Lo temperaturecontrols prevent conditionsfrom exceeding upper orlower temperature limits

• Available in 15 chambersizes and 5 temperatureranges

• 12 month warranty

Lab-Line’s 96 Series V.I.P. Walk-in EnvironmentalChambers provide accurate digital temperature controland excellent temperature uniformity designed for a widevariety of industrial and research uses—includingproduct stability testing, shelf-life testing, productconditioning, and electronic breakdown testing.

♦ Standard temperature ranges are ambient +10°C to60°C; 0°C to 60°C; 0°C to ambient; –15°C to ambient;–15°C to 60°C

♦ Positive-pressure ceiling plenum

♦ Modular panel construction with 4" of foamed-in-place urethane insulation

Model V.I.P. “96 Series”

V.I.P. Control Console������������

������������

����������������ENVIRONMENTAL ROOM

AIR FLOW

AVAILABLE OPTIONS

S stainless steel interior

H/D controlled humidification/dehumidification

R3/R4 chart recorders

P access ports

V internal vapor proof outlets

U personnel safety alarm

O internal or external entrance ramps

V.I.P. Walk-Ins

Page 13: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPTIONS AVAILABLE1: S2, H, G, D, CD, V,T, F, P, R3, R4, M

OPTIONAL CONDENSING UNITS AVAILABLE

Air cooled, hermetic, remote mounted in building Water cooled, hermetic, mounted on chamber roof

Air cooled, hermetic, remote mounted outside building3 Water cooled, hermetic, remote mounted in building

Air cooled, semi-hermetic, mounted on chamber roof Water cooled, semi-hermetic, mounted on chamber roof

Air cooled, semi-hermetic, remote mounted within building Water cooled, semi-hermetic, remote mounted in building

Air cooled, semi-hermetic, remote mounted outside building3

OTHER OPTIONS

Free standing shelving (see p. 32) Internal entry ramp 34"W × 20"D (86cm × 51cm)

Wall mounted shelving (specify requirements on drawings) External entry ramp 34"W × 24"D (86cm × 61cm)

Plugmold - outlets 18" (46cm) on center Personnel safety alarm

Remote alarm contacts for connection to building alarm system Special size doors and windows (specify sizes)

1 See 700 series options for descriptions (pp. 7–8).2 Interior on the V.I.P. series will be 22 ga. on walls and ceiling. 16 ga. on floor.3 All outdoor condensing units will be provided with winterized controls and weather hood.

100

90

80

70

60

50

40

30

20

10

05 10 15 20 25 30 35 40 45 50 55 60

TEMPERATURE/HUMIDITY PERFORMANCE CHART%R.H.

°C

Upper limit of Humidification byCentrifugal Atomizer (Option H)

Humidification by SteamGenerator (Option G)

Dehumidification byChemical Dryer (Option CD)

Lower limit of Dehumidificationby Refrigeration (Option D)

Centrifugal Atomizer Steam GeneratorDehumidification by RefrigerationDehumidification by Chemical Dryer

This chart shows the temperature/humidity set points which can be achieved by the various humidification/dehumidificationoptions. To use the chart, locate the desired temperature set point along the horizontal axis, and the desired humidity setpoint along the vertical axis. Follow the line of the temperature set point upward until it intersects the humidity set point line.The area into which the intersection point falls will indicate the optional equipment that is necessary to achieve it. For example,if the point falls within the area bounded by the lines for Options H and D, this equipment will be required.1 If the point fallswithin the area above the Option H line, Option G will be needed (dehumidification will not). If the point falls below the OptionD line, a chemical dryer (Option CD) will be necessary.2 1Some set points may require only Option H. Contact Lab-Line for details.

2Options D or CD must be used with either Option H or Option G.

Page 14: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPERATING SPECIFICATIONS AND ORDERING INFORMATION*

Interior Dim. Exterior Dim.Amps Temp. Range Comp. W x D1 W x D2 Net Weight

Model Req. °C H.P. (m) (m) lbs. (kg)

62104 28 Ambient plus 10° to 60° N/A 871 (395.1)

62204 33 0° to 60° 1/21070 (485.4)

62304 23 0° to Ambient 1/2 5'2" x 4'21/2" 5'10" x 4'101/2"

62404 25 –15° to Ambient 1(1.6 x 1.3) (1.8 x 1.5)

1100 (499.0)62504 35 –15° to 60° 1

62106 29 Ambient plus 10° to 60° N/A 1009 (457.7)

62206 34 0° to 60° 1/21200 (544.3)

62306 34 0° to Ambient 1/2 5'2" x 6'11/2" 5'10" x 6'91/2"

62406 26 –15° to Ambient 1(1.6 x 1.9) (1.8 x 2.1)

1238 (561.6)62506 36 –15° to 60° 1

62108 31 Ambient plus 10° to 60° N/A 1182 (536.2)

62208 36 0° to 60° 3/41411 (640.0)

62308 26 0° to Ambient 3/4 5'2" x 8'1/2" 5'10" x 8'81/2"

62408 28 –15° to Ambient 1(1.6 x 2.5) (1.8 x 2.7)

1418 (643.2)62508 38 –15° to 60° 1

62110 33 Ambient plus 10° to 60° N/A 1356 (615.1)

62210 36 0° to 60° 3/41585 (719)

62310 26 0° to Ambient 3/4 5'2" x 9'111/2" 5'10" x 10'71/2"

62410 30 –15° to Ambient 11/2(1.6 x 3.0) (1.8 x 3.2)

1613 (731.2)62510 40 –15° to 60° 11/2

62112 43 Ambient plus 10° to 60° N/A 1530 (694.0)

62212 48 0° to 60° 11766 (801.1)

62312 28 0° to Ambient 1 5'2" x 11'101/2" 5'10" x 12'61/2"

62412 32 –15° to Ambient 11/2(1.6 x 3.6) (1.8 x 3.8)

1787 (810.6)62512 52 –15° to 60° 11/2

73104 32 Ambient plus 10° to 60° N/A 965 (437.7)

73204 37 0° to 60° 3/41194 (541.6)

73304 23 0° to Ambient 3/4 6'11/2" x 4'21/2" 6'91/2" x 4'101/2"

73404 25 –15° to Ambient 1 (1.9 x 1.3) (2.1 x 1.5)1201 (544.8)

73504 39 –15° to 60° 1

73106 35 Ambient plus 10° to 60° N/A 1112 (504.4)

73206 40 0° to 60° 3/41342 (608.7)

73306 26 0° to Ambient 3/4 6'11/2" x 6'11/2" 6'91/2" x 6'91/2"

73406 28 –15° to Ambient 1 (1.9 x 1.9) (2.1 x 2.1)1349 (611.9)

73506 42 –15° to 60° 1

73108 35 Ambient plus 10° to 60° N/A 1303 (591.0)

73208 40 0° to 60° 11540 (698.5)

73308 26 0° to Ambient 1 6'11/2" x 8'1/2" 6'91/2" x 8'81/2"

73408 30 –15° to Ambient 11/2(1.9 x 2.5) (2.1 x 2.7)

1560 (707.6)73508 44 –15° to 60° 11/2

73110 50 35° to 60° N/A 1495 (678.1)

73210 53 0° to 60° 1 1732 (785.6)

73310 26 0° to Ambient 1 6'11/2" x 9'111/2" 6'91/2" x 10'71/2" 1732 (785.6)

73410 30 –15° to Ambient 11/2(1.9 x 3.0) (2.1 x 3.2)

1752 (794.7)

73510 57 –15° to 60° 11/2 1752 (794.7)

Page 15: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS OPERATING SPECIFICATIONS AND ORDERING INFORMATION* (CONT.)

Interior Dim. Exterior Dim.Amps Temp. Range Comp. W x D1 W x D2 Net Weight

Model Req. °C H.P. (m) (m) lbs. (kg)

73112 50 Ambient plus 10° to 60° N/A 1704 (772.9)

73212 57 0° to 60° 11/2 1961 (889.5)

73312 30 0° to Ambient 11/2 6'11/2" x 11'101/2" 6'91/2" x 12'61/2" 1961 (889.5)

73412 34 –15° to Ambient 2(1.9 x 3.6) (2.1 x 3.8)

2040 (925.3)

73512 61 –15° to 60° 2 2040 (925.3)

96104 38 Ambient plus 10° to 60° N/A 1271 (576.5)

96204 43 0° to 60° 3/4 1500 (680.4)

96304 23 0° to Ambient 3/4 8'1/2" x 4'21/2" 8'81/2" x 4'101/2" 1500 (680.4)

96404 25 to15° to Ambient 1(2.5 x 1.3) (2.7 x 1.5)

1507 (683.6)

96504 45 to15° to 60° 1 1507 (683.6)

96106 41 Ambient plus 10° to 60° N/A 1524 (691.3)

96206 46 0° to 60° 3/4 1753 (795.2)

96306 26 0° to Ambient 3/4 8'1/2" x 6'11/2" 8'81/2" x 6'91/2" 1753 (795.2)

96406 30 –15° to Ambient 11/2(2.5 x 1.9) (2.7 x 2.1)

1781 (807.9)

96506 50 –15° to 60° 11/2 1781 (807.9)

96108 41 Ambient plus 10° to 60° N/A 1745 (791.5)

96208 46 0° to 60° 1 1981 (898.6)

96308 26 0° to Ambient 1 8'1/2" x 8'1/2" 8'81/2" x 8'81/2" 1981 (898.6)

96408 30 –15° to Ambient 11/2(2.5 x 2.5) (2.7 x 2.7)

2002 (908.1)

96508 50 –15° to 60° 11/2 2002 (908.1)

96110 50 Ambient plus 10° to 60° N/A 1993 (904.0)

96210 55 0° to 60° 1 2231 (1012.0)

96310 28 0° to Ambient 1 8'1/2" x 9'111/2" 8'81/2" x 10'71/2" 2231 (1012.0)

96410 34 –15° to Ambient 2(2.5 x 3.0) (2.7 x 3.2)

2250 (1020.6)

96510 61 –15° to 60° 2 2250 (1020.6)

96112 50 Ambient plus 10° to 60° N/A 2236 (1014.2)

96212 59 0° to 60° 11/2 2492 (1130.4)

96312 32 0° to Ambient 11/2 8'1/2" x 11'101/2" 8'81/2" x 12'61/2" 2492 (1130.4)

96412 36 –15° to Ambient 2(2.5 x 3.6) (2.7 x 3.8)

2572 (1166.7)

96512 63 –15° to 60° 2 2572 (1166.7)

1Interior height is 7'10"—subtract 14" for ceiling plenum.2Exterior height on all chambers is 8'6" not including top mounted equipment. Allow 36" above outside height to accommodate this equipment, if required.3All standard controls are wired for 208-230/1/60 Hz. All standard condensing units are wired for 208-230/1/60 Hz. Other electrical characteristics are availableupon request.

4All chambers are shipped knocked down via padded van for assembly on site.5All chamber sections are designed for easy passage through any 30" × 80" doorway.*If turnkey (field) installation is required, contact Lab-Line.

Page 16: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

900 Series Frigid Cab ®

The 900 Series of Lab-Line Frigid Chambers provide aneconomical alternative for research and product testingapplications which require fixed temperature storage without the need for sophisticated, higher cost environmental manipulation.

♦ Two basic systems available:

Medium Temperature (MT) = +4°C;

Low Temperature (LT) = –23°C

♦ Self-contained, air-cooled condensing units

♦ Turnkey installation available

♦ Digital temperature readout

♦ Audible and visual alarms alert user to high-lowtemperature conditions

Model 900

♦ Modular panel construction with 4" of foamed-in-place urethane insulation

♦ Floor is 14 gauge galvanized steel with a stationaryload capacity of 600 pounds per square foot

♦ Available options include remote condensing units,shelving, and alarms (see list below)

OPTIONS AVAILABLE

Condensing units (same as V.I.P. series) Stainless steel interior

Shelving (same as V.I.P. series) White baked-on enamel finish interior and/or exterior

Chart recorders (same as 700 series) Entry ramps (same as V.I.P. series)

Vapor proof incandescent lighting Vapor proof 48" dual fixture fluorescent lighting

• Economical cold storage of serums and biological samples

• Two temperature options: +4°C or –23°C

• Temperature control ±2°C accuracy

• Chamber available in 49 standard sizes—from 18 to 196 sq. ft.

• 1 year warranty on chambers, 5 year warranty on compressor only

Page 17: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPERATING SPECIFICATIONS AND ORDERING INFORMATION

Int. Dim.2 Ext. Dim.3 Int. Floor Comp Size4 Shipping Weight, lbs. (kg.)Model W x D (m) W x D (m) sq. ft. (sq. m) MT LT MT LT

900 3'4" x 5'4" (1.0 x 1.6) 4'0"x 6'0" (1.2 x 1.8) 18 (1.7) 1/2 3/4 780 (353.8) 900 (408.2)

901 4'4" x 5'4" (1.3 x 1.6) 5'0" x 6'0" (1.5 x 1.8) 23 (2.1) 1/2 3/4 863 (391.5) 973 (441.4)

902 5'4" x 5'4" (1.6 x 1.6) 6'0" x 6'0" (1.8 x 1.8) 28 (2.6) 1/2 1 936 (424.6) 1071 (485.8)

903 5'4" x 6'4" (1.6 x 1.9) 6'0" x 7'0" (1.8 x 2.1) 34 (3.2) 1/2 11/2 1035 (469.5) 1330 (603.3)

904 5'4" x 7'4" (1.6 x 2.2) 6'0" x 8'0" (1.8 x 2.4) 39 (3.6) 1/2 11/2 1104 (500.8) 1399 (634.6)

905 5'4" x 8'4" (1.6 x 2.5) 6'0" x 9'0" (1.8 x 2.7) 44 (4.1) 3/4 11/2 1263 (572.9) 1488 (675.0)

906 5'4" x 9'4" (1.6 x 2.8) 6'0" x 10'0" (1.8 x 3.1) 50 (4.7) 3/4 11/2 1328 (602.4) 1553 (704.4)

907 6'4" x 6'4" (1.9 x 1.9) 7'0" x 7'0" (2.1 x 2.1) 40 (3.7) 1/2 11/2 1125 (510.3) 1420 (644.1)

908 6'4" x 7'4" (1.9 x 2.2) 7'0" x 8'0" (2.1 x 2.4) 46 (4.1) 3/4 11/2 1281 (581.1) 1506 (683.1)

909 6'4" x 8'4" (1.9 x 2.5) 7'0" x 9'0" (2.1 x 2.7) 53 (4.9) 3/4 11/2 1375 (623.7) 1600 (725.8)

910 6'4" x 9'4" (1.9 x 2.8) 7'0" x 10'0" (2.1 x 3.1) 59 (5.5) 3/4 11/2 1446 (655.9) 1671 (758.0)

911 6'4" x 10'4" (1.9 x 3.2) 7'0" x 11'0" (2.1 x 3.4) 65 (6.0) 3/4 2 1553 (704.4) 1838 (833.7)

912 6'4" x 11'4" (1.9 x 3.5) 7'0" x 12'0" (2.1 x 3.7) 72 (6.7) 1 2 1666 (755.7) 1921 (871.4)

913 6'4" x 12'4" (1.9 x 3.8) 7'0" x 13'0" (2.1 x 4.0) 78 (7.3) 1 2 1750 (793.8) 2015 (914.1)

914 7'4" x 7'4" (2.2 x 2.2) 8'0" x 8'0" (2.4 x 2.4) 54 (5.0) 3/4 11/2 1387 (629.1) 1612 (731.2)

915 7'4" x 8'4" (2.2 x 2.5) 8'0" x 9'0" (2.4 x 2.7) 61 (5.7) 3/4 2 1514 (686.8) 1799 (816.0)

916 7'4" x 9'4" (2.2 x 2.8) 8'0" x 10'0" (2.4 x 3.1) 68 (6.3) 3/4 2 1584 (718.5) 1869 (847.8)

917 7'4" x 10'4" (2.2 x 3.2) 8'0" x 11'0" (2.4 x 3.4) 76 (7.1) 1 2 1722 (781.1) 1977 (896.8)

918 7'4" x 11'4" (2.2 x 3.5) 8'0" x 12'0" (2.4 x 3.7) 83 (7.7) 1 2 1814 (822.8) 2069 (938.5)

919 7'4" x 12'4" (2.2 x 3.8) 8'0" x 13'0" (2.4 x 4.0) 90 (8.4) 1 2 1921 (871.4) 2176 (987.0)

920 7'4" x 13'4" (2.2 x 4.1) 8'0" x 14'0" (2.4 x 4.3) 98 (9.1) 1 2 1991 (903.1) 2246 (1018.8)

921 8'4" x 8'4" (2.5 x 2.5) 9'0" x 9'0" (2.7 x 2.7) 69 (6.4) 3/4 2 1587 (719.9) 1872 (849.1)

922 8'4" x 9'4" (2.5 x 2.8) 9'0" x 10'0" (2.7 x 3.1) 78 (7.3) 1 2 1710 (775.7) 1965 (891.3)

923 8'4" x 10'4" (2.5 x 3.2) 9'0" x 11'0" (2.7 x 3.4) 86 (8.0) 1 2 1818 (824.6) 2073 (940.3)

924 8'4" x 11'4" (2.5 x 3.5) 9'0" x 12'0" (2.7 x 3.7) 94 (8.7) 1 2 1913 (867.7) 2168 (983.4)

925 8'4" x 12'4" (2.5 x 3.8) 9'0" x 13'0" (2.7 x 4.0) 103 (9.6) 1 2 2030 (920.8) 2285 (1036.5)

926 8'4" x 13'4" (2.5 x 4.1) 9'0" x 14'0" (2.7 x 4.3) 111 (10.3) 1 2 2113 (958.5) 2368 (1074.1)

927 8'4" x 14'4" (2.5 x 4.4) 9'0" x 15'0" (2.7 x 4.6) 119 (11.1) 1 2 2221 (1007.4) 2476 (1123.1)

928 9'4" x 9'4" (2.8 x 2.8) 10'0" x 10'0" (3.1 x 3.1) 87 (8.1) 1 2 1794 (813.8) 2049 (929.4)

929 9'4" x 10'4" (2.8 x 3.2) 10'0" x 11'0" (3.1 x 3.4) 96 (8.9) 1 2 1917 (869.6) 2172 (985.2)

930 9'4" x 11'4" (2.8 x 3.5) 10'0" x 12'0" (3.1 x 3.7) 106 (9.9) 1 2 2011 (912.2) 2266 (1027.8)

931 9'4" x 12'4" (2.8 x 3.8) 10'0" x 13'0" (3.1 x 4.0) 115 (10.7) 1 2 2141 (971.2) 2396 (1086.8)

932 9'4" x 13'4" (2.8 x 4.1) 10'0" x 14'0" (3.1 x 4.3) 124 (11.5) 1 2 2223 (1008.4) 2518 (1142.2)

933 9'4" x14'4" (2.8 x 4.4) 10'0" x 15'0" (3.1 x 4.6) 134 (12.5) 1 3 2356 (1068.7) 2651 (1202.5)

934 9'4" x 15'4" (2.8 x 4.7) 10'0" x 16'0" (3.1 x 4.9) 143 (13.3) 11/2 3 2610 (1183.9) 2745 (1245.1)

935 10'4" x 10'4" (3.2 x 3.2) 11'0" x 11'0" (3.4 x 3.4) 107 (9.9) 1 2 2056 (932.6) 2311 (1048.3)

936 10'4" x 11'4" (3.2 x 3.5) 11'0" x 12'0" (3.4 x 3.7) 117 (10.9) 1 2 2150 (975.2) 2405 (1090.9)

937 10'4" x 12'4" (3.2 x 3.8) 11'0" x 13'0" (3.4 x 4.0) 127 (11.8) 11/2 3 2451 (1111.8) 2546 (1154.9)

938 10'4" x 13'4" (3.2 x 4.1) 11'0" x 14'0" (3.4 x 4.3) 138 (12.8) 11/2 3 2523 (1144.4) 2658 (1205.7)

939 10'4" x 14'4" (3.2 x 4.4) 11'0" x 15'0" (3.4 x 4.6) 148 (13.8) 11/2 3 2661 (1207.0) 2796 (1268.3)

940 10'4" x 15'4" (3.2 x 4.7) 11'0" x 16'0" (3.4 x 4.9) 158 (14.7) 11/2 3 2745 (1245.1) 2880 (1306.4)

941 10'4" x 16'4" (3.2 x 5.0) 11'0" x 17'0" (3.4 x 5.2) 169 (15.7) 11/2 3 2906 (1318.2) 3041 (1379.4)

942 11'4" x 11'4" (3.5 x 3.5) 12'0" x 12'0" (3.7 x 3.7) 128 (11.9) 11/2 3 2392 (1085.0) 2527 (1146.2)

943 11'4" x 12'4" (3.5 x 3.8) 12'0" x 13'0" (3.7 x 4.0) 140 (13.0) 11/2 3 2557 (1159.9) 2692 (1221.1)

944 11'4" x 13'4" (3.5 x 4.1) 12'0" x 14'0" (3.7 x 4.3) 151 (14.0) 11/2 3 2643 (1198.9) 2778 (1260.1)

945 11'4" x 14'4" (3.5 x 4.4) 12'0" x 15'0" (3.7 x 4.6) 162 (15.1) 11/2 3 2789 (1265.1) 2924 (1326.3)

946 11'4" x 15'4" (3.5 x 4.7) 12'0" x 16'0" (3.7 x 4.9) 174 (16.2) 11/2 3 2877 (1305.2) 3012 (1366.2)

947 11'4" x 16'4" (3.5 x 5.0) 12'0" x 17'0" (3.7 x 5.2) 185 (17.2) 11/2 3 3042 (1379.9) 3177 (1441.1)

948 11'4" x 17'4" (3.5 x 5.3) 12'0" x 18'0" (3.7 x 5.5) 196 (18.2) 11/2 3 3113 (1412.1) 3253

1Add suffix of “MT”or “LT” to denote desired temperature: i.e., 900-MT = +4°C., 900-LT = –23°C.2Interior height is 7'10".3Exterior height is 8'6" not including top mounted equipment.4 1⁄2 HP and 3⁄4 HP condensing units 208-220/1/60; 1, 11⁄2 and 3 HP condensing units 208-220/3/60.Other electrical requirements available on request.

Page 18: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

Model 3550DT

Model 3554-35

• Available in 3 chamber sizesand 2 temperature ranges

• Forced air circulation and quiet-running fan provide temperaturecontrol and uniformity

• Durable enameled steel exterior

• Many features and optionsavailable—pick the chamberthat’s right for your application

• Appropriate for B.O.D. testing

• 12 month warranty

♦ Models 3554-35 and 3554-37 featuremicroprocessor-based temperature control withdigital LED readout

♦ Models 3550DT, 3550DT-1, 3554-40, 3554-41,3554-42 and 3554-43 feature dual set pointmicroprocessor control with a seven day timer thatallows two temperatures to be set and switchedautomatically

♦ Models 3554-35 through 3554-43 have enameled

Model 3554-37

Ambi Hi-Lo ® Chambers

The Lab-Line Ambi-Hi-Lo Chambers are designed forquality performance in a wide variety of applications,from general incubations to serum studies, enzymeassays, and B.O.D. testing—perfect for clinics,hospitals, public health and life science laboratories,sewage treatment plants, and industry.

♦ Model 3550 features economical undercounter designwith high/low safety thermostat back-ups andspace-saving internal mount control panel

♦ Model 3550DT has easy-access side mounted control

Page 19: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPERATING SPECIFICATIONS

B.O.D. Shelf AreaTemperature Temperature Bottle No. of sq. ft.

Model Range Uniformity Capacity Shelves (sq. m)

3550

3550-1+5°C to 50°C

2 6.53550DT

92 Fixed (0.60)

3550-1DT

3554-355 Fixed

17.43554-36

–2°C to 60°C 355 (1.62)

3554-37 5 Adjustable

22

3554-38 –2°C to 60°C

±0.5°C

495 (2.04)

3554-40 355 5 Fixed 17.4

3554-41 –2°C to 60°C (1.62)

3554-42 495 5 Adjustable 22

3554-43–2°C to 60°C

(2.04)

ORDERING INFORMATION

Chamber ExteriorChamber Dimensions Dimensions Net Wt. Ship. Wt.

Volume cu. ft. W" x D" x H" W" x D" x H" lbs. lbs.Model Volts* Amps Watts (<) (cm) (cm) (kg) (kg)

3550 120 4.0 233⁄8 x 233⁄4 x 331⁄2 100 115

3550-1 220 2.2 5.5 201⁄2 x 183⁄8 x 213⁄8 (59 x 60 x 85) (45) (52)

3550DT 120 4.0480 (156) (52 x 46 x 54) 267⁄8 x 233⁄4 x 331⁄2 140 155

3550-1DT 220 2.2 (68 x 60 x 85) (64) (70)

3554-35 120 7.0 19 22 x 20 x 56 32 x 291⁄2 x 731⁄2 260 420

3554-36 220 3.8840

(538) (56 x 51 x 142) (81 x 75 x 187) (118) (191)

3554-37 120 11.0 28 34 x 21 x 67 35 x 33 x 76 360 570

3554-38 220 6.01320 (793) (86 x 53 x 170) (89 x 84 x 193) (163) (259)

3554-40 120 7.0840 19 22 x 20 x 56 32 x 291⁄2 x 731⁄2 260 420

3554-41 220 3.8 (538) (56 x 51 x 142) (81 x 75 x 187) (118) (191)

3554-42 120 11.01320 28 34 x 21 x 67 35 x 33 x 76 360 570

3554-43 220 6.0 (793) (86 x 53 x 170) (89 x 84 x 193) (163)

*120 Models rated 60Hz.; 220V Models rated 50Hz.

Page 20: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• Two chamber sizes: 20 and 25 cu.ft.

• Temperature control from –5°C to 55°C (+10°C to 55°C with lights on)

• 24-hour timer/programming forlighting, heating and cooling

♦ Durable enamel-finished steel chamber construction

♦ Day and night thermostats with selector switch

♦ Adjustable Hi-Lo thermostats provide temperatureback-up to safeguard samples

♦ Accurate LED temperature display

♦ Four 20 watt adjustable fluorescent lamps plus twofixed 25 watt incandescent lamps for more than1,000 foot candles of illumination

♦ Four chamber shelves and five door shelves foradditional space come as standard equipment

The Biotronette Mark II line of plant chambers aredesigned to facilitate many botanical and agricultural researchapplications, including seed germination studies, plantpathology, plant tissue culture studies, and plant

ORDERING INFORMATION

Chamber Shelf Chamber Overall Electrical Volume Area Dimensions Dimensions Net Wt. Ship Wt.

Volts/Phase/ Req’d Temp. cu. ft. sq. ft. W" x D" x H" W" x D" x H" lbs. lbs.Model Hz. Amps Watts Range (<) (sq. m) (cm) (cm) (kg) (kg)

844 120/1/60

844-1 220/1/60

844-2 220/1/5020 1020 –5°C to 55°C 20 12.1 27 x 20 x 50 32 x 29.5 x 77.9 276 391

845* 120/1/60 (566) (1.1) (69 x 51 x 127) (81 x 75 x 198) (125) (177)

845-1* 220/1/60

845-2* 220/1/50

*These models feature controlled humidification from ambient dew point to 70% R.H., +5% R.H.

ACCESSORIES

Model Description Used On

844-6 Extra Shelves 844, 845

848-6 Extra Shelves 848

Model 844

Biotronette ® Plant Growth Chamber

Page 21: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• 28 cu. ft. chamber capacity

• Combination lamp switchesallow for five stages oflighting

• 24-hour timer/programmersfor temperature, lighting, and humidity

• 12 month warranty

Lab-Line’s Plant Growth Chambers are ideal for manyresearch applications such as plant and seedenvironmental response studies, germinationacceleration or retardation of seeds, and microbiologicalculture propagation.

♦ Durable all-steel chamber construction, finished inwhite acrylic enamel

♦ LED readout day and night thermostats

♦ Adjustable Hi-Lo protection thermostats to safeguardsamples

♦ Lockable control box

♦ Four fixed incandescent lamps and ten fluorescentlamps provide 1,000 foot candles of illumination

Model 850

Model 850 Control Panel

OPERATING SPECIFICATIONS

RelativeTemperature Humidity

Model Ranges Range*

-5°C to 55°C (No Lights) Ambient

to 75%850+15°C to 55°C

(All Lights)

*Ambient to 40% with all lights on.

ORDERING INFORMATION

Electrical Chamber Dim. Overall Dim. Net Wt. Ship. Wt.Service Required Required W" x D" x H" W" x D" x H" lbs. lbs.

Model Volts/Phase/Hz. Amps (cm) (cm) (kg.) (kg.)

850 120/1/6030 221⁄2 x 23 x 58 36 x 31 x 711⁄2 396 456

850-1 220/1/50 (57 x 58 x 147) (91 x 79 x 182) (180) (207)

Model 850

AVAILABLE OPTIONS

H humidification by spray nozzle

V internal electrical outlet

Page 22: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• Great for seed germination, planttissue cultures, plant pathologystudies and plant geneticresearch

• Available in three chamber sizes

• Microprocessor-based P.I.D.temperature control

• Adjustable height, broadspectrum light bank

• CFC-free refrigerant

• 12 month warranty

♦ 24 hour timers with programmable temperature andlighting

♦ Multiple lighting circuits allow for different lightinglevels

♦ High and low temperature protection

♦ Accurate LED temperature display

♦ Eight adjustable fluorescent lamps plus eight fixed25 watt incandescent lamps provide more than1,000 foot candles of illumination

♦ Easy-to-clean reflective white interior

♦ Walk-in models feature modular panel construction and 3" foamed-in-place insulation

Large Capacity Plant Growth Chamber

Many plant growth applications require a chamber withgreater capacity than the standard reach-in models. Tomeet these needs, Lab-Line offers a line of largecapacity plant growth chambers in reach-in or walk-inmodels. These chambers are ideal for applicationsmaking use of extended growth height or growth area. Inaddition, Lab-Line’s large capacity chambers feature amixture of fluorescent and incandescent lights—toprovide the broadest light spectrum for best plant

OPERATING SPECIFICATIONS AND ORDERING INFORMATION

Model Voltage Style Temp. Range Lighting Int. Dimen. Ext. Dimen. Growth area Ship Wt.

852 120/60 750

852-1 220/60 Reach-in 0° to 60°C one bank 70 x 26 x 65 78 x 33 x 903⁄4 12 sq. ft. 780

852-2 220/50 780

854 220/60 1700

854-2 220/50Walk-in 0° to 60°C one bank 4'6" x 4'6" x 6'10" 5' x 5' x 7'11" 12 sq. ft.

1800

856 220/60 2100

856-2 220/50Walk-in 0° to 60°C two banks 4'6" x 6' x 6'10" 5' x 6'6" x 7'11" 24 sq. ft.

2200

AVAILABLE OPTIONS

H humidification

R4 chart recorder

Model 852

Model 852 Control Panel

Page 23: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

Custom Plant Growth Chambers

Lab-Line’s standard plant chambers are designed toaccommodate a wide variety of uses in educational andresearch settings. Some applications, however, mayrequire different specifications than are available inthe standard models. For these situations, Lab-Line

• Microprocessor-based maintemperature controller

• Positive pressure ceilingplenum

• Horizontal air flow

• Modular panel constructionwith 4" of foamed-in-placepolyurethane insulation

• Dual RTD sensors

• Reflective white interior

• Locking control panelprotects controls,improves safety andrepeatability

options and a price quotation.

Available Options Include:

♦ Controlled humidification/dehumidification

♦ Chart recorders

♦ Internal electrical outlets

♦ Access ports

♦ Personnel safety alarm

♦ Shelves

♦ Internal or external entrance ramps

♦ Custom door sizes

♦ Special lighting applications

♦ Custom condensing unit requirements—hermetic, semihermetic, top mount, remotemount, air cooled, water cooled, outdoor

♦ Turnkey installation available

Walk-In Plant Growth Chamber

Walk-In Control Panel Bank

offers customized plant growth chambers. Custom plantchambers can be built to accommodate any size or floorplan configuration required, with the specificequipment options that are needed for your particularapplication. Contact Lab-Line for more information on

Page 24: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

• Ideal for growing plants in theclassroom

• Automatic 24 hourprogramming

• 14 cu. ft. interior

• Sliding glass doors for easyaccess and viewing

• 12 month warrantyModel 846

ACCESSORIES

Model Description

846-6 Culture Dish Shelf

846-7 Petri Dish Shelf

846-8 Chamber Shelf [(61⁄ 2" x 491⁄2")(16.5cm x 125.7cm)]

846-9 Screen Frame

846-11 Gridded Photo Background

846-12 Mobile Chamber Stand

846-13 Planting Tray (Pkg. of 4)

846-14 Disposable Growth Pouch (Pkg. of 100)

846-15 Frame Support for 846-14 Growth Pouch

846-16 Hangers for 846-14 Growth Pouches

846-17 Reference Manual of Environmental Studies

ORDERING INFORMATION

ChamberElectrical Volume Shelf Area Chamber Dimensions Overall Dimensions Net Wt. Ship Wt.

Volts/Phase/ cu. ft. sq. ft. W" x D" x H" W" x D" x H" lbs. lbs.Model Hz. Watts (<) (sq. m) (cm) (cm) (kg) (kg)

846 120/1/60 14 2.2 50 x 17 x 29 52 x 181⁄2 x 38 189 236846-3 220/1/50

800 (396) (.20) (127 x 43 x 74) (132 x 47 x 97) (86.0) (107)

The Lab-Line Educational Chambers are speciallydesigned to accommodate plant, animal, and culturestudies in the classroom setting. The Model 846 seriescombine a large viewing area with simplifiedtemperature controls and an economical price—perfectfor educational use.

♦ Lighting consists of 4 fluorescent and 3 incandescent

lamps

♦ 2 interior electrical outlets

♦ Main power switch; lampswitch; heater output, fan,thermostat, and 24timer/programmerswitches all have on/off

Model 846

See pages 21–24for

Plant Growth

Page 25: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

ACCESSORIES

Model Description

F Extra Light Shelf (Factory Installed ) NOTE: Each addedShelf elevates chamber temperature

C Cooling Unit for 849-2 and 849-6

ORDERING INFORMATION

ChamberElectrical Volume3 Shelf Area3 Chamber Dimensions Overall Dimensions Net Wt. Ship Wt.

Volts/Phase cu. ft. sq. ft. W" x D" x H" W" x D" x H" lbs. lbs.Model Hz. Watts (<) (sq. m) (cm) (cm) (kg) (kg)

17.6 4.5 261/2 x 251/4 x 451/2 56 x 281/2 x 74 620 1130849-61 120/1/60 220 (498.4) (.42) (67 x 64 x 116) (142 x 72 x 188) (281) (513)

849-6C2 Same as 849-6 except comes with cooling (Requires an additional 1600 watts)

849-7 Same as 849-6 except comes with heavy duty casters 634 1144(288) (519)

1Requires 20 amp NEMA connection.2Requires two 20 amp NEMA connections.3Each Chamber

• Two separate chambers withindividual controls

• Temperatures from just aboveambient to 38°C (with lights off)

• Each chamber has its own 24-hourtimer for light and temperaturecontrol

• 12 month warranty

Biotronette ® Mark IV Plant Growth Chamber

Lab-Line’s Biotronette Mark IV Plant Growth chambersare designed for use in seed germination and plantbiology studies in the school classroom or laboratory.

♦ Separate switches for lights on shelves and chambertop allow for different lighting conditions betweenchambers or between top and bottom of same chamber

♦ Available cooling unit for operation to 10°C belowambient (lights off)/5°C below ambient (lights on)

♦ Attractive maple hardwood chamber exterior

♦ Easy-to-clean white enamel chamber interior

♦ Hi-Lo limit thermostats protect samples andexperimental conditions

♦ Plexiglass control panel cover locks for addedsecurity

Model 849-6

See pages 21–24for

Plant Growth

Page 26: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

Model 849-2

ACCESSORIES

Option Description Used On

C Cooling Unit to provide controlled temperatures 849-2, 849-3, 849-4,to 10°C below ambient. (Factory installed) 849-6

OPERATING SPECIFICATIONS AND ORDERING INFORMATION

Capacity Shelf Area Interior Dim. Exterior Dim.Electrical3 cu. ft. sq. ft. W" x D" x H" W" x D"x H" Net Wt. Shipping Wt.

Model Volts/Phase/Hz Watts (<) (sq. m) (cm) (cm) lbs. (kg) lbs. (kg)

Animal Study849-2 25.4

725 (329) 910 (413)

849-31120/1/60 900 34 (2.4) 54 x 24 x 451⁄2 56 x 281⁄2 x 74 727 (330) 912 (414)

849-42 (963) (137 x 61 x 116) (142 x 72 x 188) 741 (336) 927 (420)

Aviary849-5 N/A 695 (315) 880 (399)

1Same as 849-2 except with charcoal and dust filters for indoor venting.2Same as 849-3 except mounted on heavy duty casters.3Other electrical characteristics available upon request.

• Offers full observation ofanimals or birds

• Temperature from slightlyabove ambient to 38°C

• Hi-Lo limit thermostats forsafety

• 12 month warranty

Animal Study Chamber and Aviary

Ideal for classroom or laboratory use, the Model 849-2Animal Study Chamber is designed to house smalllaboratory animals such as mice, rats, or guinea pigs,while the Model 849-5 Aviary accommodates smallbirds for study and observation.

♦ Hardwood maple cabinet exterior

♦ Easy-to-clean white enamel interior

♦ Low light transmission glass in doors

♦ Animal Study Chambers have two sliding glass doorswith key lock, three adjustable wire shelves, twostainless steel pull-out trays, and removable meshbottom

♦ Aviary features one sliding door with removablescreen, two access openings, four adjustable sideperches and center perch, removable mesh bottom,and charcoal and dust filters for indoor venting

Page 27: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

OPERATING SPECIFICATIONS

Interior Dim. Overall Dim. Capacity Shelf AreaModel Temperature W" x D" x H" W" x D" x H" cu. ft. sq. ft.

Ranges (cm) (cm) (<) (sq. m)

Refrigerator –7°C to 25°C 251⁄2 x 22 x 40 13.5Incubator Slightly Above Ambient to 40°C (65 x 56 x 102) 56 x 281⁄2 x 74 (382) 45

849 (4.2)Freezer – 20°C 221⁄2 x 24 x 163⁄4 (142 x 72 x 188) 5.2

(57 x 61 x 43) (147)

ORDERING INFORMATION

Electrical2 Net Weight Shipping WeightModel Volts/Phase/Hz. Watts lbs. (kg) lbs. (kg)

849 120/1/60 680 (308.4) 1070 (485.4)

849-0 220/1/60 2000 680 (308.4) 1070 (485.4)

849-11 120/1/60 694 (314.8) 1084 (491.7)

1Same as 849 except mounted on heavy duty casters.2Other electrical characteristics available upon request.

• Three chambers in one cabinet—incubator, refrigerator, and freezer

• Three temperature ranges:slightly above ambient to 40°C (incubator), –7°C to 25°C(refrigerator), –20°C(freezer)

• Relative humidity control to 85% R.H.

• 12 month warranty

Model 849

Designed for classroom or laboratory use, the Lab-Line Model 849 Controlled Environment Center combinesthree different chambers into one practical unit.

♦ Attractive maple hardwood cabinet

♦ Hi-Lo limit thermostats for sample protection

♦ Key locks on chamber doors

Controlled Environment Centers

♦ Adjustable shelves

♦ Insulated doors

♦ Triple pane windows in incubator and refrigeratorcompartments for easy viewing

Page 28: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

Model 890

OPERATING SPECIFICATIONS

Temperatures Controlled Volume Shelves Shelf AreaEquipment °C Relative cu. ft. and/or sq. ft. W" x D" x H"

Min Max Humidity (<) Trays (sq. m) (cm)

Complete BIOLOGICAL 62 x 27 x 82WORK STATION –7° 60° 85% 251/2 (722) 12 501/2 (4.7) (157 x 69 x 208)

INCUBATOR – Viewing SlightlyWindow, Electrical Above 60° 85% 8 (227) 3 111/2 (1.1)Outlet and Light Ambient 24 x 24 x 24

INCUBATOR – Solid Slightly (61 x 61 x 61)Door, Electrical Above 60° 85% 8 (227) 3 111/2 (1.1)Outlet and Light Ambient

Freezer –7° –7° — 3 (85) 2 4 (0.4) 111⁄2 x 201⁄2 x 221⁄2 (29 x 52 x 57)

Refrigerator –7° 21° — 31⁄4 (92) 2 61⁄4 (0.6)121⁄2 x 201⁄2 x 221⁄2

Gradient Chamber with (32 x 52 x 57)Electrical Outlet and Light –7° 21° — 31⁄4 (92) — 61⁄4 (0.6)

Work Center — — — — 2 10 (0.9) 60 x 24(152 x 61)

• Complete classroom laboratory work station

• Five storage and experimentalchambers

• Temperature range from –7°C to60°C

• Humidity control to 85% R.H.

• 12 month warranty

Refrigerator with five plastic-coated wire shelves

Temperature-gradient chamber with 25 wattincandescent lamp and five plastic-coated wireshelves

Work center with two stainless steel shelves, chromehosecock, sink with brass trap, 40 watt fluorescentlight with switch, duplex electrical outlet

♦ Cabinet exterior has maple hardwood frame

Biological Work Station

The self-contained Lab-Line Model 890 BiologicalWork Station is perfect for classroom use, providingfacilities to conduct studies involving tissue or cellculture incubation and preparation as well as storageof cultures in the dormant state, all in one unit.

♦ Standard equipment includes:

Two incubators with six perforated stainless steelshelves

Freezer with four fiberglass trays

Page 29: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

Model SL1000

• Four series of chambers in a variety of models, for:

—Kesternich tests

—Salt spray (fog) tests

—Cyclic corrosion tests

• Completely seamless, molded construction iscorrosion-proof, rust-proof, shock-proof, andpractically maintenance-free

• 12 month warranty

Corrosion Test Chambers

Whatever your corrosion testing application, there’s aLab-Line Corrosion Test Chamber designed to meet yourneeds.

♦ Kesternich Chambers —for condensation water testsand Kesternich tests using sulphur dioxide: twomodels, one manual and one partly automated

♦ Bench Top Condensation Chambers—for condensationwater testing and Kesternich tests: eight modelsavailable ranging from fully manual to fullyautomatic, computerized operation

♦ Salt Spray/Cyclic Test Chambers —twelve modelsavailable: SL models for salt spray tests range from150 < to 2000 < capacity; SK models for alternatingtest climates range from 400 < to 2000 < capacity;SKA for programmed cyclic testing; KTS for fullyautomated testing procedures

♦ Chest Type Chambers —six models available in 400 <and 1000 < capacities for salt spray and alternating

Model KTS-2000

Model KSE-300/I

Page 30: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

ORDERING INFORMATION

Capacity Chamber Dimensions Overall Dimensions Net Wt.ft3 Temperature W" x D" x H" W" x D" x H" lbs.

Model No. Volts/Hz. (liters) Range (cm) (cm) (kg)

KESTERNICH CHAMBERS

KSE–300220/60 10.4 Ambient to 29.6 x 19.7 x 30.7 43.3 x 25.6 x 37.8 132

KSE–300/I (295) 50°C.1 (75 x 50 x 78) (110 x 65 x 96) (60)

BENCH TOP CONDENSATION CHAMBERS

KT–300KT–300/IKT–300/II 9.1 26 x 21.5 x 28.2 48.9 x 25.6 x 40.8 198KT–300/III 220/60 (258) Ambient to (66 x 55 x 72) (124 x 65 x 104) (90)

KT–300/IV 50°C1

KT–300/VKT–1000/I 32.8 38.2 x 34.7 x 42.7 70.9 x 39.4 x 77.4 418KT–1000/II (929) (97 x 88 x 108) (180 x 100 x 197) (190)

SALT SPRAY/CYCLIC TEST CHAMBER

5.2 25.6 x 9.8 x 28.1 48.8 x 25.6 x 40.7 265SL–150 (147) (65 x 25 x 71) (124 x 65 x 103) (120)

SL400 814(369)

13.1 28 x 27.6 x 29.2 59.1 x 31.5 x 75.6 770SK–400 (371) (71 x 70 x 74) (150 x 80 x 192) (349)

SKA–400 880(399)

SL–1000 990(449)

SK–1000 105632.8 Ambient to 38.2 x 34.7 x 42.7 70.9 x 39.4 x 77.4 (479)

SKA–1000220/60 (929) 55°C. (97 x 88 x 108) (180 x 100 x 197) 1025

(465)

KTS–1000 1100(499)

SL–2000 1650(748)

SK–2000 176065.8 82.7 x 32.9 x 41.8 114.3 x 39.4 x 77.4 (798)

SKA–2000(1863) (210 x 84 x 106) (290 x 100 x 197) 1800

(816)

KTS–2000 1870(848)

CHEST TYPE CHAMBERS

STR–400 440(200)

STK–40012.8 33.9 x 22.9 x 28.4 86.7 x 33.5 x 46.92 484(362) (86 x 58 x 72) (220 x 85 x 119) (220)

STA–400 520

220/60Ambient to (236)

STR–100055°C. 660

(299)

STK–100033.6 53.2 x 30.7 x 35.5 110.3 x 43.3 x 543 704(951) (135 x 78 x 90) (280 x 110 x 137) (319)

680STA–1000 (308)

1Temperature to +60°C. on special order.2Overall height with lid open: 62.6" (159 cm)3Overall height with lid open 74.9" (190 cm)

Page 31: 960198 Environ Chmbs - Cole-ParmerEnviron-Cab® Series Lab-Line’s Environ-Cab series of chambers is designed to provide accurate environmental control of temperature and humidity

EN

VIR

ON

ME

NT

AL

CH

AM

BE

RS

ORDERING INFORMATION

Size Size SizeD" x W" D" x W" D" x W"

(cm) (cm) (cm)

18 x 24 (46 x 61) 21 x 24 (53 x 61) 24 x 24 (61 x 61)18 x 30 (46 x 76) 21 x 30 (53 x 76) 24 x 30 (61 x 76)18 x 36 (46 x 91) 21 x 36 (53 x 91) 24 x 36 (61 x 91)18 x 42 (46 x 107) 21 x 42 (53 x 107) 24 x 42 (61 x 107)18 x 48 (46 x 122) 21 x 48 (53 x 122) 24 x 48 (61 x 122)18 x 54 (46 x 137) 21 x 54 (53 x 137) 24 x 54 (61 x 137)18 x 60 (46 x 152) 21 x 60 (53 x 152) 24 x 60 (61 x 152)18 x 72 (46 x 183) 21 x 72 (53 x 183) 24 x 72 (61 x 183)

• Shelves available in fivematerials: zinc plate, chromeplate, epoxy coated, stainlesssteel, and reinforced polymer

• Assemble easily without theneed for any special tools

Shelving

Lab-Line also offers modular, free-standing shelving foruse in environmental chambers.

♦ Shelf depths of 18", 21", and 24" in zinc plate,chrome plate, epoxy coated and stainless steel

♦ Reinforced polymer shelves available in 18" and 24"depths

♦ Shelf ribs run front to back for ease of use

♦ Posts available in chrome plate, epoxy coated,