9
PRODUCT SHEET: L100258 #971 WETPUMP LOW INLET, BOTTOM OUTLET TRULY DAMAGE-FREE FISH TRANSFER The patented RYCO Fish Wetpump will pump faster, with less damage, than any other wetpump built. ANYWHERE. Bruising, broken necks, scale loss all are common in other wetpumps with high inlets. Such pump designs have inlets up to several feet higher than the RYCO wetpump, and the first fish into the tank are thrown several feet into the end of the tank, suffering high measurable damage. The RYCO patented Low Inlet Wetpump avoids this damage by bringing the fish into a hooded air chamber at the inlet valve. The fish enter the tank close to the bottom, and the velocity is greatly reduced. An additional advantage of the RYCO design is the reduced suction height, which in many cases allows the RYCO Wetpump to move fish at two or three times the rate of similar sized pumps in similar installations. The RYCO design is also the lower profile of this pump, several feet lower than other wetpumps. Pump can be located in low overhead locations where no other fish pump would fit. Our automatic wetpumps use standard compressed air valves and air cylinders. This system will not freeze up in cold air, and is easily maintained in remote locations by untrained employees. This is the most bulletproof control system available. FEATURES: Pumps up to 80 tons/ hour with 30 hp. • Tanks available from 30 to 600 cubic ft. • Blowers from 100 to 2500 cfm • Automatic pumps easily operated manually • Manual pumps easily converted to auto • Suction heights to 20 feet • Discharge heights to 50 feet • Discharge distances to 2000 feet • Tanks and frames are stainless • Diesel, electric, hydraulic, or gas drives • Power units integral or remote UTILITIES: Water: fresh or salt, 5 gpm, 30 psi (min.) • Automatic cycle requires 1 cfm air at 100 psi overleaf D4041-A1 SPECFICATIONS MAY CHANGE, CONTACT RYCO FOR SPECIFIC APPLICATIONS Address: 6810 220 th St. SW Mountlake Terrace, WA 98043 USA Phone Fax 425-744-0444 425-673-2666 Web: E-mail: rycous.com [email protected] FOOD PROCESSING SYSTEMS AND EQUIPMENT

#971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE

  • Upload
    others

  • View
    29

  • Download
    0

Embed Size (px)

Citation preview

Page 1: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE

PRODUCT SHEET: L100258

#971 WETPUMP LOW INLET, BOTTOM OUTLET

TRULY DAMAGE-FREE FISH TRANSFER

The patented RYCO Fish Wetpump will pump faster, with less damage, than any other wetpump built. ANYWHERE.

Bruising, broken necks, scale loss all are common in other wetpumps with high inlets. Such pump designs have inlets up to several feet higher than the RYCO wetpump, and the first fish into the tank are thrown several feet into the end of the tank, suffering high measurable damage. The RYCO patented Low Inlet Wetpump avoids this damage by bringing the fish into a hooded air chamber at the inlet valve. The fish enter the tank close to the bottom, and the velocity is greatly reduced.

An additional advantage of the RYCO design is the reduced suction height, which in many cases allows the RYCO Wetpump to move fish at two or three times the rate of similar sized pumps in similar installations.

The RYCO design is also the lower profile of this pump, several feet lower than other wetpumps.

Pump can be located in low overhead locations where no other fish pump would fit. Our automatic wetpumps use standard compressed air valves and air cylinders. This system will not freeze up in cold air, and is easily maintained in remote locations by untrained employees. This is the most bulletproof control system available.

FEATURES:

• Pumps up to 80 tons/ hour with 30 hp.• Tanks available from 30 to 600 cubic ft.• Blowers from 100 to 2500 cfm• Automatic pumps easily operated manually• Manual pumps easily converted to auto• Suction heights to 20 feet• Discharge heights to 50 feet• Discharge distances to 2000 feet• Tanks and frames are stainless• Diesel, electric, hydraulic, or gas drives• Power units integral or remote

UTILITIES:

• Water: fresh or salt, 5 gpm, 30 psi (min.)• Automatic cycle requires 1 cfm air at 100 psi overleaf D4041-A1

SPECFICATIONS MAY CHANGE, CONTACT RYCO FOR SPECIFIC APPLICATIONS

Address: 6810 220th St. SWMountlake Terrace, WA 98043USA

Phone Fax

425-744-0444425-673-2666

Web:E-mail:

rycous.com [email protected]

FOOD PROCESSING SYSTEMS AND EQUIPMENT

Page 2: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE
Page 3: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE

PRODUCT SHEET: L110196

#974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE

RYCO #970 SERIES WETPUMP:TRULY DAMAGE - FREE FISH TRANSFER

The patented RYCO Fish Wetpump will pump faster, with less damage, than any other wetpump built ANYWHERE.

This pump is similar to the RYCO #971 in all respects except the discharge tank head, which is an eccentric cone. This design removes all flow path corners, and assures a truly obstruction free path for the largest fish.

For further information about accessories and details, see the specifications for the #971 Wetpump.

FEATURES:

• Pumps up to 80 tons/hour with 30 hp.

• Pumps tanks from 50 to 300 cubic ft.

• Blowers from 100 to 2000 cfm

• Automatic pumps easily converted to auto

• Suction heights to 20 feet

• Discharge heights to 50 feet

• Tanks and frames are stainless

• Diesel, electric, hydraulic or gas drives

• Power units integral or remote

UTILITIES:

• Water: fresh or salt, 5 gpm, 30 psi (min)

• Automatic cycle requires 1 cfm air at 100 psi

SPECIFICATIONS MAY CHANGE, CONTACT RYCO FOR SPECIFIC APPLICATIONS OVERLEAF: D4009-04

Address: 6810 220th St. SWMountlake Terrace, WA 98043USA

Phone:Fax:

425-744-0444425-673-2666

Web:E-mail:

rycous.com [email protected]

FOOD PROCESSING SYSTEMS AND EQUIPMENT

Page 4: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE
Page 5: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE

PRODUCT SHEET: L110065

#971 DOUBLE WETPUMP LOW INLET, BOTTOM OUTLET

RYCO #970 SERIES DOUBLE WETPUMP: TRULY DAMAGE-FREE FISH TRANSFER

The patented RYCO #971 Double Wetpump will pump faster, with less damage, than any other wetpump built. ANYWHERE.

The RYCO #971 Double Wetpump uses two #971 wetpumps. with special cast inlet and outlet manifolds to allow connection of a single inlet and outlet hoses to the two tanks.

In addition, a simple cycle control insures that the two tanks always operate in unison.

A feature of RYCO Double Pump Cycle control is the ability to operate either tank independently.

See the RYCO #971 Wetpump product sheet for more information on this pump.

FEATURES:• Double Wetpump with two 30 hp motors

will pump over 120 tons per hour• Pump tanks from 50 to 300 cubic ft.• Blowers from 100 to 2000 CFM• Automatic pumps easily operated

manually• Manual pumps easily converted to auto• Suction heights to 20 feet• Discharge heights to 50 feet• Tanks and frames are stainless• Diesel, electric, hydraulic, or gas drives• Power units integral or remote

UTILITIES:• Water: fresh or salt, 5 gpm, 30 psi (min.)• Automatic cycle requires 1 cfm air at 100

psi

SPECIFICATIONS MAY CHANGE, CONTACT RYCO FOR SPECIFIC APPLICATIONS OVERLEAF:D4009-03D

Address: 6810 220th St. SWMountlake Terrace, WA 98043USA

Phone:Fax:

425-744-0444425-673-2666

Web:E-mail:

rycous.com [email protected]

FOOD PROCESSING SYSTEMS AND EQUIPMENT

Page 6: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE
Page 7: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE
Page 8: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE
Page 9: #971 WETPUMP LOW INLET, BOTTOM OUTLETrycous.com/pdf/971 All Wetpump Products.pdf · #974 WETPUMP LOW INLET, BOTTOM OUTLET CONICAL DISCHARGE RYCO #970 SERIES WETPUMP: TRULY DAMAGE