N/en 5.4.372.01 10/10 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting with NAMUR hole pattern Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. For single and double operated actuators Exhaust air recirculation (3 way function) Crossover-free switching, switch-over function guaranteed even with small cross section air supply Manual override with detent Simple design of soft seal spool system Compact design and easily interchangeable solenoid The solenoid valves are applicable in the protection class Ex m and Ex ia, for zones 1, 2 (gases) ATEX cat.II 2 G, Ex nA, for zones 2 (gases), 22 (dust) ATEX cat.II 3 GD Medium: Filtered, non-lubricated or dry compressed air Operation: Indirectly solenoid operated soft seal valves Mounting position: Optional Flow direction: Fixed Orifice: 6 mm Port size: 1: G 1/4, 1/4 NPT 3 and 5: G 1/8, 1/8-NPT Electrical connection: See solenoid table Operating pressure: 2 ... 8 bar Operating temperature: Valve: -15 ... +60°C, Solenoid: see table Air supply must be dry enough to avoid ice formation at temperatures below +2°C. Technical features Materials: Housing: Aluminium anodized Pilot flange: Plastic (PBT) Seals: NBR (Perbunan) Connector See datasheet N/en 7.7.002

97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

N/en 5.4.372.0110/10

97100 NAMUR3/2, 5/2 & 5/3 way indirect solenoid operated valves

G 1/4, 1/4 NPT or flange mounting with NAMUR hole pattern

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

For single and double operated actuatorsExhaust air recirculation (3 way function)Crossover-free switching, switch-over function guaranteed even with small cross section air supplyManual override with detentSimple design of soft seal spool systemCompact design and easily interchangeable solenoidThe solenoid valves are applicable in the protection class Ex m and Ex ia, for zones 1, 2 (gases) ATEX cat.II 2 G, Ex nA, for zones 2 (gases), 22 (dust) ATEX cat.II 3 GD

Medium: Filtered, non-lubricated or dry compressed airOperation: Indirectly solenoid operated soft seal valvesMounting position: OptionalFlow direction: Fixed

Orifice: 6 mmPort size: 1: G 1/4, 1/4 NPT 3 and 5: G 1/8, 1/8-NPTElectrical connection: See solenoid tableOperating pressure: 2 ... 8 bar

Operating temperature: Valve: -15 ... +60°C, Solenoid: see table Air supply must be dry enough to avoid ice formation at temperatures below +2°C.

Technical featuresMaterials: Housing: Aluminium anodized Pilot flange: Plastic (PBT) Seals: NBR (Perbunan)

Connector See datasheet N/en 7.7.002

Page 2: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

10/10N/en 5.4.372.02

97100 NAMUR

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

Solenoid operators for standard version 971xxx0 onlyPower consumption24 V d.c. (W)

230 V a.c. (VA)

Nominal current24 V d.c.(mA)

230 V a.c.(mA)

Ex-Protection(ATEX-Category)

Protection class *7) Temperature Ambient/Fluid (°C)

Weight

(kg)

Dimension

No.

CircuitdigramNo.

Model

1,6 3,5 - IP 65 (with Connector DIN EN 175301-803 Form A) *6)

-15 ... +50 0,1 5 1 3036

2 - 85 - II3GII3D

Ex nA II T5 Ex tDA22 IP65 T95° with special connectorDIN EN 175301-803 Form A

-15 ... +50 0,3 5 1 3046

- 4,0 - - II3GII3D

Ex nA II T5 Ex tDA22 IP65 T95° with special connectorDIN EN 175301-803 Form A

-15 ... +50 0,3 5 1 3047

2,7 - 115 - II2GII2D

Ex mb II T5 Ex tDA21 IP65 T95° with 3 m cable

-20 ... +50 0,3 6 1 3062 *3)

- 2,1 - 9 II2GII2D

Ex mb II T5 Ex tDA21 IP65 T95° with 3 m cable

-20 ... +50 0,3 6 8 3063 *3)

2,7 - 115 - - IP 66 with Connector M12x1 DIN IEC 61076-2-101 *8)with yellow LED

-10 ... +50 0,1 7 17 3071

Standardvoltages 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.*3) EG-Type-Examination-Certificate PTB 03 ATEX 2015X *6) Connector cable gland not supplied, see table »Accessories« required connector for DC: type 0680003 Form B, type 0570275 Form A.*7) IP-Protection class according to EN60529*8) Connector according to DIN IEC 61076-2-101 not supplied

Technical data Standard version, 5/2 or 3/2 directional valves (see conversion instructions at page 6)

Symbol Port size1 3, 5 2, 4

Actuation Operating pressure (bar)

Flow (l/min)

Weight (kg)

DimensionNo.

Model *1)

G 1/4 G 1/8 Flange Solenoid/spring 2 ... 8 750 0,25 1 9710000

1/4 NPT 1/8 NPT Flange 9710010

G 1/4 G 1/8 Flange Solenoid/solenoid 2 ... 8 750 0,35 2 9711000

1/4 NPT 1/8 NPT Flange Solenoid/solenoid 9711010

G 1/4 G 1/8 Flange Solenoid/solenoid 2 ... 8 500 0,40 3 9712000

1/4 NPT 1/8 NPT Flange Solenoid/solenoid 9712010

mid position APB

*1) When ordering please indicate solenoid, voltage and current type (frequency). Outside free of nonferrous metalsValve function: APB = All Ports Blocked

3

4 2

4 2

4 2

5 31

1

1

5 3

2 3

V-32spec-EM-F

V-32spec-EMH-F

V-32spec-EMR-F

24

15 3

24

15 3

24

15 3

V-52-EM-F

V-52-EMH-F

V-52-EMH-F

3

4 2

4 2

4 2

5 31

1

1

5 3

2 3

V-32spec-EM-EM

V-32spec-EMH-EMH

V-32spec-EMR-EMR

24

15 3

24

15 3

15 3

24

V-52B-EM

V-52B-EMH

V-52B-EMR

4 2

5 1 3

4 2

5 1 3

V-53A-EMH

4 2

5 1 3V-53A-EM

V-53A-EMR

Page 3: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

10/10 N/en 5.4.372.03

97100 NAMUR

Valves for minimal electrical power, incl. Ex i, 5/2 or 3/2 way valves, directional actuated (conversation intsructions see page 6)

Symbol Port size1 3, 5 2, 4

Actuation Operating pressure (bar)

Flow (l/min)

Weight (kg)

DimensionNo.

Model *1)

G 1/4 G 1/8 Flange Spring 2 ... 8 750 0,25 1 9710002

1/4 NPT 1/8 NPT Flange 9710012

G 1/4 G 1/8 Flange Solenoid/solenoid 2 ... 8 750 0,35 2 9711002

1/4 NPT 1/8 NPT Flange Solenoid/solenoid 9711012

G 1/4 G 1/8 Flange Solenoid/solenoid 2 ... 8 500 0,40 3 9712002

1/4 NPT 1/8 NPT Flange Solenoid/solenoid mid position APB

2 ... 8 500 0,40 3 9712012

*1) When ordering please indicate solenoid, voltage and current type (frequency). Outside free of nonferrous metalsValve function: APB = All Ports Blocked

Solenoid operatorsPower consumption24 V d.c. (W)

230 V a.c. (VA)

Nominal current24 V d.c.(mA)

230 V a.c.(mA)

Ex-Protection(ATEX-Category)

Protection class *7) Temperature Ambient/Fluid (°C)

Weight

(kg)

Dimension

No.

CircuitdigramNo.

Model

1,7 - 70 - IP 65 (with Connector DIN EN 175301-803 Form B) *6)

-15 ... +50 0,1 4 1 3050

0,7 0,8 *2) 29 4 IP 65 (with Connector DIN EN 175301-803 Form A) *6)

-15 ... +50 0,1 5 1 3034

2 - 85 - II3GII3D

Ex nA II T5 Ex tDA22 IP65 T95° with special connectorDIN EN 175301-803 Form A

-15 ... +50 0,3 5 1 3046

2,7 - 115 - II2GII2D

Ex mb II T5 Ex tDA21 IP65 T95° with 3 m cable

-20 ... +50 0,3 6 1 3062 *3)

- 2,1 - 9 II2GII2D

Ex mb II T5 Ex tDA21 IP65 T95° with 3 m cable

-20 ... +50 0,3 6 8 3063 *3)

2,7 - 115 - - IP 66 with Connector M12x1 DIN IEC 61076-2-101 *8)with yellow LED

-10 ... +50 0,3 7 17 3071

Standardvoltages 24 V d.c., 230 V a.c., other voltages on request. Design according to VDE 0580, EN 50014/50028. 100% duty cycle.

For intrinsically safe circuits, Protection class Ex ia IIC T6/T4 (cat. II 2G)

Nominal resistance RN coil (Ω)

Required switching current min. (mA)

Resistance RW 50 coil(Ω)

Required voltage at terminal RW 50 (V)

Temperature Ambient/Fluid (°C)

Weight

(kg)

Dimension

No.

Circuit diagram

No.

Model

275 37 345 13,8 T6 -40 ... +50/+70T4 -40 ... +85/+80

0,83 8 13 3039 *4)

*2) Valves can be operated with DC only. For 230V AC application please use 206V DC coil together with recifier plug 0663303*3) EG-Type-Examination-Certificate PTB 03 ATEX 2015X *4) Certificate of Conformity PTB 03 Atex 2134 PTP 03 IEC 2166, CSA - Certificate No. LR 51090-4, FM approved. Required connector acc. to DIN EN 17031-801 form A or ISO 4400. Installation acc. to requirements of FM and CSA. Connector cable gland not supplied, see table »Accessories«*6) Connector cable gland not supplied, see table »Accessories« required connector for DC: type 0680003 Form B, type 0570275 Form A.*7) IP-Protection class according to EN60529*8) Connector according to DIN IEC 61076-2-101 not supplied

3

4 2

4 2

4 2

5 31

1

1

5 3

2 3

V-32spec-EM-F

V-32spec-EMH-F

V-32spec-EMR-F

24

15 3

24

15 3

24

15 3

V-52-EM-F

V-52-EMH-F

V-52-EMH-F

3

4 2

4 2

4 2

5 31

1

1

5 3

2 3

V-32spec-EM-EM

V-32spec-EMH-EMH

V-32spec-EMR-EMR

24

15 3

24

15 3

15 3

24

V-52B-EM

V-52B-EMH

V-52B-EMR

4 2

5 1 3

4 2

5 1 3

V-53A-EMH

4 2

5 1 3V-53A-EM

V-53A-EMR

Page 4: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

10/10N/en 5.4.372.04

97100 NAMUR

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

24

13

5

01

M5

3

5.5

19.5

13

25 7.2

37.2

32

40

G 1

/4G

1/8

24

1224

.4

20.5

56.5

38.5

131.

5

31

5

42

01

01

M5

3

5.5

19.5

13

25 7.2

37.2

32

40

G 1

/4G

1/8

24

1295

.5

1818

110

203

Dimensions

Valves

1 2 3

Options selector 971˙0˙˙.˙˙˙˙.˙˙˙.˙0

Voltage Substitute

24 V d.c. 024.0

230 V a.c. 230.5

Solenoids Substitute

see table

Manual override Substitute

Push and lock 0

Push and lock, Ex i version only 5

Function Substitute

5/2 way valve, spring return (3/2 way valve by swapping enclosed adator plate)

0

5/2 way impuls valve (3/2 way valve by swapping enclosed adator plate)

1

5/3 way valve, APB (all ports blocked)

2

Port size Substitute

G 1/4 0

1/4 NPT 1Ordering example5/2 way valve, directional actuated, port size G1/4,solenoid 24 V d.c. with connector form A, protection class IP65 Valve: 9710003.3034.024.00Connector: 0570275

ConnectorForm A M12 x 1

Silencer *1)

Page 8

Exhaust guard *2)

Page 8

Flange plate

Page 7

Yoke

Page 7

0570275 0523055 (without cable) 0523056 (90°, without cable) C/S2 1/4 NPT 0613422 (G1/4, 1/4 NPT) 0612790 (NAMUR single connection plate) 0540593

0523057 (2 m cable) 0523058 (90°, 2 m cable length M/S2 G 1/4 0612791 (NAMUR-rip use in combination with 0612790, Alu)

0523052 (5 m cable) 0523053 (90°, 5 m cable length

*1) For indoors use*2) For outdoors use

Accessories

Page 5: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

10/10 N/en 5.4.372.05

97100 NAMUR

1 Connector 4 x 90° turnable

4 5

Dimensions

Solenoid operators

29

65 12

11

29,5

22

Ø9

6 7

29,5

38,5 10

14,5

29,5

M12

x1

12

34

5

14

23

Pin Signal Cable

1 + UB brown

2 Out 2 (PNP) / analogue 4 to 20 mA white

3 0 Volt blue

4 Out 1 (PNP) black

Electrical connection M 12 x 1

29

29

,52

2

~58

Ø9

39

18

72

29,5

30

Ø9

15,5

41,5

M16 X 1,5 12

1

28

8

Ø9

29,5

36

15

41,5

69

15

30

M16 X 1,5 12

1

28

Page 6: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

10/10N/en 5.4.372.06

97100 NAMUR

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

NAMUR hole pattern

2 Port 2 (A)

3 Coding stud threaded

4 M5 & M6 (10 deep)

5 Port 3 (R)

Conversion instructions of 5/2 into 3/2 way function

5/2 way function (original mode of supply)

3/2 way function

6 Arrow

7 Marker

3/2 resp. 5/2 way function can be achieved just by swapping enclosed adaptor plates. Make sure Marker and Arrow do match as shown on above drawing. Original mode of supply: 5/2 function.

Circuit diagrams

1 8 13 17

M5

32

2

24

3

3

5

4

2

5/2

67

3/2

67

1

23

4

NAMUR quick exhaust module for a better kv-value by exhaust see data sheet 5.4.820

NAMUR interlinking plates in redundancy design for »safety exhausting« and »safety ventilating« see data sheet 5.4.830

Page 7: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

10/10 N/en 5.4.372.07

97100 NAMUR

Single connection plate Model: 0612790

NAMUR slot Model: 0612791

Yoke Model: 0540593

19

12 12

34,5

104

2127ø 9 ø 14,5

25,5 M 5

41

25,5

1616

M 5

11,5

19

1012

29

35

3019

ø 5,5 ø 9,5 G 1/4

19

G 1

/4

19

41

60°

11

51

9,5

512

5,5

5,5

205

12

65

2x

50 M 5

41

Page 8: 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated ......10/10 N/en 5.4.372.01 97100 NAMUR 3/2, 5/2 & 5/3 way indirect solenoid operated valves G 1/4, 1/4 NPT or flange mounting

10/10N/en 5.4.372.08

97100 NAMUR

Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document.

Silencer Model: M/S2, C/S2

Exhaust guard Model: 0613422

26,5

10

ø 2

1

1/4”

ø 1

5,5

42,5

8

1/4”

Warning

These products are intended for use in industrial compressed airsystems only. Do not use these products where pressures andtemperatures can exceed those listed under ‘Technical data’.Before using these products with fluids other than those specified,for non-industrial applications, life-support systems, or otherapplications not within published specifications, consult NORGREN.Through misuse, age, or malfunction, components used in fluidpower systems can fail in various modes.

The system designer is warned to consider the failure modes of allcomponent parts used in fluid power systems and to provide adequatesafeguards to prevent personal injury or damage to equipment in theevent of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specific warnings found in instruction sheets packed and shipped with these products.