346
1414 W. Sam Houston Pkwy N., Suite 160, Houston, TX 77043 Phone: 281-705-3926 Fax: 832-295-6404 www.pei-tx.com Providing Environmental Solutions Worldwide Compliance · Engineering · Remediation · Mercury & Toxic Metals April 24, 2020 Rhonda Romero New Mexico Environment Department Air Quality Bureau 525 Camino de los Marquez, Suite 1 Santa Fe, New Mexico, 87505 RE: Significant Revision to NSR Permit 7877 Cowboy CDP XTO Energy Inc. Dear Ms. Romero: XTO Energy Inc. is submitting the attached application for a significant revision to NSR Permit 7877. See Section 3 for details regarding the nature of the permit revisions. Please note Tab 24 of the permit application contains information XTO Energy Inc. deems Confidential Business Information. Two copies of the application have been provided, along with two copies of the confidential information, which are provided in a manila folder. Also included are CDs containing the electronic and modeling files, as well as a check for the filing fee. If you have any questions regarding these applications, please contact me at (865) 850- 2007 or [email protected]. Sincerely, Evan Tullos Vice President

A-7877 UA2 and Calculations XTO Cowboy CDP 03.15.20 · 2020-05-29 · 7877. See Section 3 for details regarding the nature of the permit revisions. Please note Tab 24 of the permit

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

  • 1414 W. Sam Houston Pkwy N., Suite 160, Houston, TX 77043 Phone: 281-705-3926 Fax: 832-295-6404 www.pei-tx.com

    Providing Environmental Solutions Worldwide Compliance · Engineering · Remediation · Mercury & Toxic Metals

    April 24, 2020 Rhonda Romero New Mexico Environment Department Air Quality Bureau 525 Camino de los Marquez, Suite 1 Santa Fe, New Mexico, 87505 RE: Significant Revision to NSR Permit 7877 Cowboy CDP XTO Energy Inc. Dear Ms. Romero:

    XTO Energy Inc. is submitting the attached application for a significant revision to NSR Permit 7877. See Section 3 for details regarding the nature of the permit revisions. Please note Tab 24 of the permit application contains information XTO Energy Inc. deems Confidential Business Information. Two copies of the application have been provided, along with two copies of the confidential information, which are provided in a manila folder. Also included are CDs containing the electronic and modeling files, as well as a check for the filing fee. If you have any questions regarding these applications, please contact me at (865) 850-2007 or [email protected]. Sincerely,

    Evan Tullos Vice President

  • Environmental Engineer

    04/08/2020

    PREPARED BY:Benjamin Schneider

    Cowboy CDP

    Eddy County, New Mexico

    NSR Modification Permit Application

  • UA1 Form - Company and Facility Information

    UA2 Form - Application Tables

    Section 3 - Application Summary

    Section 4 - Process Flow Sheet

    Section 5 - Plot Plan Drawn To Scale

    Section 6 - All Calculations

    Section 7 - Information Used To Determine Emissions

    Section 8 - Map(s)

    Section 9 - Proof of Public Notice

    Section 10 - Written Description of the Routine Operations of the Facility

    Section 11 -Source Determination

    Section 12 - PSD Applicability Determination for All Sources

    Section 13 - Determination of State & Federal Air Quality Regulations

    Section 14 - Operational Plan to Mitigate Emissions

    Section 15 - Alternative Operating Scenarios

    Section 16 - Air Dispersion Modeling

    Section 17 - Compliance Test History

    Section 18 - Addendum for Streamline Applications (Not Applicable)

    Section 19 - Requirements for Title V Program

    Section 20 - Other Relevant Information

    Section 21 - Addendum for Landfill Applications (Not Applicable)

    Section 22 - Certification

    Section 23 - UA4

    Confidential PVT Fluid Study & HYSYS Model

    Cowboy CDP

    NSR Modification Permit Application

    Table of Contents

    Tab 11

    Tab 1

    Tab 2

    Tab 3

    Tab 4

    Tab 5

    Tab 6

    Tab 7

    Tab 8

    Tab 9

    Tab 10

    Tab 12

    Tab 13

    Tab 14

    Tab 15

    Tab 16

    Tab 17

    Tab 18

    Tab 19

    Tab 20

    Tab 21

    Tab 22

    Tab 23

    Tab 24

  • UA1 Form - Company and Facility Information

    Tab 1

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Form Revision: 8/12/2019 Section 1, Page 1 Printed: 4/8/2020

    Mail Application To: New Mexico Environment Department Air Quality Bureau Permits Section 525 Camino de los Marquez, Suite 1 Santa Fe, New Mexico, 87505 Phone: (505) 476-4300 Fax: (505) 476-4375 www.env.nm.gov/aqb

    For Department use only:

    AIRS No.:

    Universal Air Quality Permit Application Use this application for NOI, NSR, or Title V sources.

    Use this application for: the initial application, modifications, technical revisions, and renewals. For technical revisions, complete Sections, 1-A, 1-B, 2-E, 3, 9 and any other sections that are relevant to the requested action; coordination with the Air Quality Bureau permit staff prior to submittal is encouraged to clarify submittal requirements and to determine if more or less than these sections of the application are needed. Use this application for streamline permits as well. See Section 1-I for submittal instructions for other permits.

    This application is submitted as (check all that apply): Request for a No Permit Required Determination (no fee) Updating an application currently under NMED review. Include this page and all pages that are being updated (no fee required).

    Construction Status: Not Constructed Existing Permitted (or NOI) Facility Existing Non-permitted (or NOI) Facility Minor Source: a NOI 20.2.73 NMAC 20.2.72 NMAC application or revision 20.2.72.300 NMAC Streamline application Title V Source: Title V (new) Title V renewal TV minor mod. TV significant mod. TV Acid Rain: New Renewal PSD Major Source: PSD major source (new) minor modification to a PSD source a PSD major modification

    Acknowledgements: I acknowledge that a pre-application meeting is available to me upon request. Title V Operating, Title IV Acid Rain, and NPR applications have no fees. $500 NSR application Filing Fee enclosed OR The full permit fee associated with 10 fee points (required w/ streamlineapplications). Check No.: 1301 in the amount of $500 I acknowledge the required submittal format for the hard copy application is printed double sided ‘head-to-toe’, 2-hole punched (except the Sect. 2 landscape tables is printed ‘head-to-head’), numbered tab separators. Incl. a copy of the check on a separate page.

    This facility qualifies to receive assistance from the Small Business Environmental Assistance program (SBEAP) and qualifies for 50% of the normal application and permit fees. Enclosed is a check for 50% of the normal application fee which will be verified with the Small Business Certification Form for your company.

    This facility qualifies to receive assistance from the Small Business Environmental Assistance Program (SBEAP) but does not qualify for 50% of the normal application and permit fees. To see if you qualify for SBEAP assistance and for the small business certification form go to https://www.env.nm.gov/aqb/sbap/small_business_criteria.html ). Citation: Please provide the low level citation under which this application is being submitted: 20.2.72.219.B.1.d NMAC (e.g. application for a new minor source would be 20.2.72.200.A NMAC, one example for a Technical Permit Revision is 20.2.72.219.B.1.b NMAC, a Title V acid rain application would be: 20.2.70.200.C NMAC)

    Section 1 – Facility Information

    Section 1-A: Company Information AI # if known (see 1st 3 to 5 #s of permit IDEA ID No.):384481

    Updating Permit/NOI #: 7877

    1 Facility Name: Cowboy Central Delivery Point (CDP)

    Plant primary SIC Code (4 digits): 1311

    Plant NAIC code (6 digits): 211120

    a Facility Street Address (If no facility street address, provide directions from a prominent landmark): See 1-D.4. 2 Plant Operator Company Name: XTO Energy Inc. Phone/Fax: (832) 624-4426

    a Plant Operator Address: 22777 Springwoods Village Parkway, W4.6B.374, Spring, TX 77389

    b Plant Operator's New Mexico Corporate ID or Tax ID: 1522747

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Form Revision: 8/12/2019 Section 1, Page 2 Printed: 4/8/2020

    3 Plant Operator Company Name: XTO Energy Inc. Phone/Fax: (832) 624-4426

    a Plant Owner(s) Mailing Address(s): 22777 Springwoods Village Parkway, W4.6B.374, Spring, TX 77389

    4 Bill To (Company): XTO Energy Inc. Phone/Fax: (832) 624-4426

    a Mailing Address: 22777 Springwoods Village Parkway, W4.6B.374, Spring, TX 77389 E-mail: [email protected]

    5 Preparer: Consultant: Evan Tullos Phone/Fax: (865) 850-2007

    a Mailing Address: 5 Cardinal Court; Edwardsville, IL 620205 E-mail: [email protected]

    6 Plant Operator Contact: Benjamin Schneider Phone/Fax: (832) 624-2768

    a Mailing Address: 22777 Springwoods Village Parkway, W4.6B.374, Spring, TX 77389 E-mail: [email protected]

    7 Air Permit Contact: Benjamin Schneider Title: Environmental Engineer

    a E-mail: [email protected] Phone/Fax: (832) 624-2768

    b Mailing Address: 22777 Springwoods Village Parkway, W4.6B.374, Spring, TX 77389

    c The designated Air permit Contact will receive all official correspondence (i.e. letters, permits) from the Air Quality Bureau.

    Section 1-B: Current Facility Status 1.a Has this facility already been constructed? Yes No 1.b If yes to question 1.a, is it currently operating in New Mexico? Yes No

    2 If yes to question 1.a, was the existing facility subject to a Notice of Intent (NOI) (20.2.73 NMAC) before submittal of this application?

    Yes No

    If yes to question 1.a, was the existing facility subject to a construction permit (20.2.72 NMAC) before submittal of this application?

    Yes No

    3 Is the facility currently shut down? Yes No If yes, give month and year of shut down (MM/YY): 4 Was this facility constructed before 8/31/1972 and continuously operated since 1972? Yes No

    5 If Yes to question 3, has this facility been modified (see 20.2.72.7.P NMAC) or the capacity increased since 8/31/1972? Yes No N/A

    6 Does this facility have a Title V operating permit (20.2.70 NMAC)? Yes No If yes, the permit No. is: P-

    7 Has this facility been issued a No Permit Required (NPR)? Yes No If yes, the NPR No. is:

    8 Has this facility been issued a Notice of Intent (NOI)? Yes No If yes, the NOI No. is:

    9 Does this facility have a construction permit (20.2.72/20.2.74 NMAC)? Yes No If yes, the permit No. is: 7877

    10 Is this facility registered under a General permit (GCP-1, GCP-2, etc.)? Yes No If yes, the register No. is:

    Section 1-C: Facility Input Capacity & Production Rate 1 What is the facility’s maximum input capacity, specify units (reference here and list capacities in Section 20, if more room is required)

    a Current Hourly: 33.3 MMSCF and 62,500 Barrels Daily: 800 MMSCF and 1.5 MM Barrels Annually: 2.92 BSCF and 547.5 MM Barrels

    b Proposed Hourly: 41.7 MSCF Natural Gas 25,000 Barrels Condensate Barrels Natural Gas Liquids

    Daily: 1 MMSCF Natural Gas 600,000 Barrels Condensate 190,000 Barrels Natural Gas Liquids

    Annually: 356 MMSCF Natural Gas 219 MM Barrels Condensate 69.35 MM Barrels Natural Gas Liquids

    2 What is the facility’s maximum production rate, specify units (reference here and list capacities in Section 20, if more room is required)

    a Current Hourly: 33.3 MMSCF and 62,500 Barrels Daily: 800 MMSCF and 1.5 MM Barrels Annually: 2.92 BSCF and 547.5 MM Barrels

    b Proposed Hourly: 41.7 MSCF Natural Gas 25,000 Barrels Condensate Barrels Natural Gas Liquids

    Daily: 1 MMSCF Natural Gas 600,000 Barrels Condensate 190,000 Barrels Natural Gas Liquids

    Annually: 356 MMSCF Natural Gas 219 MM Barrels Condensate 69.35 MM Barrels Natural Gas Liquids

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Form Revision: 8/12/2019 Section 1, Page 3 Printed: 4/8/2020

    Section 1-D: Facility Location Information 1 Section: 1 Range: 30E Township: 25S County: Eddy Elevation (ft):

    2 UTM Zone: 12 or 13 Datum: NAD 27 NAD 83 WGS 84

    a UTM E (in meters, to nearest 10 meters): 609230 UTM N (in meters, to nearest 10 meters): 3558750

    b AND Latitude (deg., min., sec.): 32º 09’ 36” Longitude (deg., min., sec.): -103º 50’ 30”

    3 Name and zip code of nearest New Mexico town: Malaga - 88263 4 Detailed Driving Instructions from nearest NM town (attach a road map if necessary): Head W on Duarte Rd. for 1.3 mi. to R

    on McDonald Rd. Drive 11.2 mi. to R on Twin Wells Rd. In 0.6 mi. take slight left to stay on Twin Wells Rd. Drive 1.4 mi. to R on Buck Jackson Rd. Site will be of L in 0.6 mi.

    5 The facility is 14 (distance) miles SE (direction) of Malaga (nearest town).

    6 Status of land at facility (check one): Private Indian/Pueblo Federal BLM Federal Forest Service Other (specify)

    7 List all municipalities, Indian tribes, and counties within a ten (10) mile radius (20.2.72.203.B.2 NMAC) of the property on which the facility is proposed to be constructed or operated: Lea

    8

    20.2.72 NMAC applications only: Will the property on which the facility is proposed to be constructed or operated be closer than 50 km (31 miles) to other states, Bernalillo County, or a Class I area (see www.env.nm.gov/aqb/modeling/class1areas.html)? Yes No (20.2.72.206.A.7 NMAC) If yes, list all with corresponding distances in kilometers: Texas - 17

    9 Name nearest Class I area: Carlsbad Caverns

    10 Shortest distance (in km) from facility boundary to the boundary of the nearest Class I area (to the nearest 10 meters): 49900

    11 Distance (meters) from the perimeter of the Area of Operations (AO is defined as the plant site inclusive of all disturbed lands, including mining overburden removal areas) to nearest residence, school or occupied structure: > 5

    12

    Method(s) used to delineate the Restricted Area: Fencing “Restricted Area” is an area to which public entry is effectively precluded. Effective barriers include continuous fencing, continuous walls, or other continuous barriers approved by the Department, such as rugged physical terrain with steep grade that would require special equipment to traverse. If a large property is completely enclosed by fencing, a restricted area within the property may be identified with signage only. Public roads cannot be part of a Restricted Area.

    13

    Does the owner/operator intend to operate this source as a portable stationary source as defined in 20.2.72.7.X NMAC? Yes No A portable stationary source is not a mobile source, such as an automobile, but a source that can be installed permanently at one location or that can be re-installed at various locations, such as a hot mix asphalt plant that is moved to different job sites.

    14 Will this facility operate in conjunction with other air regulated parties on the same property? No Yes If yes, what is the name and permit number (if known) of the other facility?

    Section 1-E: Proposed Operating Schedule (The 1-E.1 & 1-E.2 operating schedules may become conditions in the permit.) 1 Facility maximum operating (hoursday ): 24

    (daysweek ): 7 (

    weeksyear ): 52 (

    hoursyear ): 8760

    2 Facility’s maximum daily operating schedule (if less than 24 hoursday )? Start: AM PM End: AM PM

    3 Month and year of anticipated start of construction: Already started

    4 Month and year of anticipated construction completion: Train 1 – May 2020, Train 2 – February 2021, Train 3 – June 2021

    5 Month and year of anticipated startup of new or modified facility: Train 1 – May 2020, Train 2 – February 2021, Train 3 – June 2021 6 Will this facility operate at this site for more than one year? Yes No Section 1-F: Other Facility Information 1 Are there any current Notice of Violations (NOV), compliance orders, or any other compliance or enforcement issues related to this facility? Yes No If yes, specify:

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Form Revision: 8/12/2019 Section 1, Page 4 Printed: 4/8/2020

    a If yes, NOV date or description of issue: NOV Tracking No:

    b Is this application in response to any issue listed in 1-F, 1 or 1a above? Yes No If Yes, provide the 1c & 1d info below:

    c Document Title: Date: Requirement # (or page # and paragraph #):

    d Provide the required text to be inserted in this permit:

    2 Is air quality dispersion modeling or modeling waiver being submitted with this application? Yes No

    3 Does this facility require an “Air Toxics” permit under 20.2.72.400 NMAC & 20.2.72.502, Tables A and/or B? Yes No

    4 Will this facility be a source of federal Hazardous Air Pollutants (HAP)? Yes No

    a If Yes, what type of source? Major ( >10 tpy of any single HAP OR >25 tpy of any combination of HAPS) OR Minor (

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Form Revision: 8/12/2019 Section 1, Page 5 Printed: 4/8/2020

    Section 1-I – Submittal Requirements Each 20.2.73 NMAC (NOI), a 20.2.70 NMAC (Title V), a 20.2.72 NMAC (NSR minor source), or 20.2.74 NMAC (PSD) application package shall consist of the following:

    Hard Copy Submittal Requirements: 1) One hard copy original signed and notarized application package printed double sided ‘head-to-toe’ 2-hole punched as we

    bind the document on top, not on the side; except Section 2 (landscape tables), which should be head-to-head. Please use numbered tab separators in the hard copy submittal(s) as this facilitates the review process. For NOI submittals only, hard copies of UA1, Tables 2A, 2D & 2F, Section 3 and the signed Certification Page are required. Please include a copy of the check on a separate page.

    2) If the application is for a minor NSR, PSD, NNSR, or Title V application, include one working hard copy for Department use. This copy should be printed in book form, 3-hole punched, and must be double sided. Note that this is in addition to the head-to-to 2-hole punched copy required in 1) above. Minor NSR Technical Permit revisions (20.2.72.219.B NMAC) only need to fill out Sections 1-A, 1-B, 3, and should fill out those portions of other Section(s) relevant to the technical permit revision. TV Minor Modifications need only fill out Sections 1-A, 1-B, 1-H, 3, and those portions of other Section(s) relevant to the minor modification. NMED may require additional portions of the application to be submitted, as needed.

    3) The entire NOI or Permit application package, including the full modeling study, should be submitted electronically. Electronic files for applications for NOIs, any type of General Construction Permit (GCP), or technical revisions to NSRs must be submitted with compact disk (CD) or digital versatile disc (DVD). For these permit application submittals, two CD copies are required (in sleeves, not crystal cases, please), with additional CD copies as specified below. NOI applications require only a single CD submittal. Electronic files for other New Source Review (construction) permits/permit modifications or Title V permits/permit modifications can be submitted on CD/DVD or sent through AQB’s secure file transfer service.

    Electronic files sent by (check one): CD/DVD attached to paper application

    secure electronic transfer. Air Permit Contact Name Benjamin Schneider Email [email protected] Phone number (832) 624-2768

    a. If the file transfer service is chosen by the applicant, after receipt of the application, the Bureau will email the applicant with instructions for submitting the electronic files through a secure file transfer service. Submission of the electronic files through the file transfer service needs to be completed within 3 business days after the invitation is received, so the applicant should ensure that the files are ready when sending the hard copy of the application. The applicant will not need a password to complete the transfer. Do not use the file transfer service for NOIs, any type of GCP, or technical revisions to NSR permits.

    4) Optionally, the applicant may submit the files with the application on compact disk (CD) or digital versatile disc (DVD) following the instructions above and the instructions in 5 for applications subject to PSD review.

    5) If air dispersion modeling is required by the application type, include the NMED Modeling Waiver and/or electronic air dispersion modeling report, input, and output files. The dispersion modeling summary report only should be submitted as hard copy(ies) unless otherwise indicated by the Bureau.

    6) If the applicant submits the electronic files on CD and the application is subject to PSD review under 20.2.74 NMAC (PSD) or NNSR under 20.2.79 NMC include, a. one additional CD copy for US EPA, b. one additional CD copy for each federal land manager affected (NPS, USFS, FWS, USDI) and, c. one additional CD copy for each affected regulatory agency other than the Air Quality Bureau.

    If the application is submitted electronically through the secure file transfer service, these extra CDs do not need to be submitted.

    Electronic Submittal Requirements [in addition to the required hard copy(ies)]:

    1) All required electronic documents shall be submitted as 2 separate CDs or submitted through the AQB secure file transfer service. Submit a single PDF document of the entire application as submitted and the individual documents comprising the application.

    2) The documents should also be submitted in Microsoft Office compatible file format (Word, Excel, etc.) allowing us to access the text and formulas in the documents (copy & paste). Any documents that cannot be submitted in a Microsoft Office compatible format shall be saved as a PDF file from within the electronic document that created the file. If you are unable to provide

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Form Revision: 8/12/2019 Section 1, Page 6 Printed: 4/8/2020

    Microsoft office compatible electronic files or internally generated PDF files of files (items that were not created electronically: i.e. brochures, maps, graphics, etc,), submit these items in hard copy format. We must be able to review the formulas and inputs that calculated the emissions.

    3) It is preferred that this application form be submitted as 4 electronic files (3 MSWord docs: Universal Application section 1 [UA1], Universal Application section 3-19 [UA3], and Universal Application 4, the modeling report [UA4]) and 1 Excel file of the tables (Universal Application section 2 [UA2]). Please include as many of the 3-19 Sections as practical in a single MS Word electronic document. Create separate electronic file(s) if a single file becomes too large or if portions must be saved in a file format other than MS Word.

    4) The electronic file names shall be a maximum of 25 characters long (including spaces, if any). The format of the electronic Universal Application shall be in the format: “A-3423-FacilityName”. The “A” distinguishes the file as an application submittal, as opposed to other documents the Department itself puts into the database. Thus, all electronic application submittals should begin with “A-”. Modifications to existing facilities should use the core permit number (i.e. ‘3423’) the Department assigned to the facility as the next 4 digits. Use ‘XXXX’ for new facility applications. The format of any separate electronic submittals (additional submittals such as non-Word attachments, re-submittals, application updates) and Section document shall be in the format: “A-3423-9-description”, where “9” stands for the section # (in this case Section 9-Public Notice). Please refrain, as much as possible, from submitting any scanned documents as this file format is extremely large, which uses up too much storage capacity in our database. Please take the time to fill out the header information throughout all submittals as this will identify any loose pages, including the Application Date (date submitted) & Revision number (0 for original, 1, 2, etc.; which will help keep track of subsequent partial update(s) to the original submittal. Do not use special symbols (#, @, etc.) in file names. The footer information should not be modified by the applicant.

    Table of Contents

    Section 1: General Facility Information Section 2: Tables Section 3: Application Summary Section 4: Process Flow Sheet Section 5: Plot Plan Drawn to Scale Section 6: All Calculations Section 7: Information Used to Determine Emissions Section 8: Map(s) Section 9: Proof of Public Notice Section 10: Written Description of the Routine Operations of the Facility Section 11: Source Determination Section 12: PSD Applicability Determination for All Sources & Special Requirements for a PSD Application Section 13: Discussion Demonstrating Compliance with Each Applicable State & Federal Regulation Section 14: Operational Plan to Mitigate Emissions Section 15: Alternative Operating Scenarios Section 16: Air Dispersion Modeling Section 17: Compliance Test History Section 18: Addendum for Streamline Applications (streamline applications only) Section 19: Requirements for the Title V (20.2.70 NMAC) Program (Title V applications only) Section 20: Other Relevant Information Section 21: Addendum for Landfill Applications Section 22: Certification Page

  • UA2 Form - Application TablesTab 2

  • Previous Unit Number Previous Source Description New Unit Number New Source Description

    1 Hot Oil Heater 1 SHTR1 Stabilization Hot Oil Heater (58.93 MMBtu/hr)

    2 Hot Oil Heater 2 SHTR2 Stabilization Hot Oil Heater (58.93 MMBtu/hr)

    3 Hot Oil Heater 3 SHTR3 Stabilization Hot Oil Heater (58.93 MMBtu/hr)

    4 Hot Oil Heater 4 SHTR4 Stabilization Hot Oil Heater(58.93 MMBtu/hr)

    5 Hot Oil Heater 5 SHTR5 Stabilization Hot Oil Heater (58.93 MMBtu/hr)

    6 Hot Oil Heater 6 SHTR6 Stabilization Hot Oil Heater (58.93 MMBtu/hr)

    7 Hot Oil Heater 7 SHTR7Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    8 Hot Oil Heater 8 SHTR8Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    9 Hot Oil Heater 9 SHTR9Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    10 Hot Oil Heater 10 SHTR10Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    11 Hot Oil Heater 11 SHTR11Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    12 Hot Oil Heater 1 CHTR1 Cryo Hot Oil Heater (94.54 MMBtu/hr)

    13 Hot Oil Heater 2 CHTR2 Cryo Hot Oil Heater (94.54 MMBtu/hr)

    14 Hot Oil Heater 3 CHTR3 Cryo Hot Oil Heater w/ SCR Catalyst(94.54 MMBtu/hr)

    15 Hot Oil Heater 4 CHTR4 Cryo Hot Oil Heater w/ SCR Catalyst(94.54 MMBtu/hr)

    16 Regen Heater 1 RHTR1 Regen Heater (35.25 MMBtu/hr)

    17 Regen Heater 2 RHTR2 Regen Heater(35.25 MMBtu/hr)

    18 Regen Heater 3 RHTR3 Regen Heater(35.25 MMBtu/hr)

    19 Regen Heater 4 RHTR4 Regen Heater(35.25 MMBtu/hr)

    20 Emergency Flare 1 FL1 Cryo Flare 1 (Dual Tip Flare)

    21 Emergency Flare 2 FL2 Stabilizer Flare 2(Dual Tip Flare)

    22 Emergency Flare 3 FL3 Backup SSM/Emergency Flare 3 (Dual Tip Flare)

    23 Tank 1 - RVP 9(50,000 bbl) IFR1Oil Storage Tank 1

    (50,000 bbl)

    24 Tank 2 - RVP 9(50,000 bbl) IFR2Oil Storage Tank 2

    (50,000 bbl)

    25 Tank 3 - RVP 10.4(50,000 bbl) IFR3Oil Storage Tank 3

    (50,000 bbl)

    26 Tank 3 - RVP 10.4(50,000 bbl) IFR4Oil Storage Tank 4

    (50,000 bbl)

    27 Tank 5 - RVP 9(250,000 bbl) IFR5Oil Storage Tank 5

    (250,000 bbl)

    28 Tank 6 - RVP 9(250,000 bbl) IFR6Oil Storage Tank 6

    (250,000 bbl)

    29 Tank 7 - RVP 9(250,000 bbl) IFR7Oil Storage Tank 7

    (250,000 bbl)

    30 Tank 8 - RVP 9(250,000 bbl) IFR8Oil Storage Tank 8

    (250,000 bbl)35 Combustor ECD1 Combustor36 TO-1 TO1 Thermal Oxidizer37 TO-2 TO2 Thermal Oxidizer38 TO-3 TO3 Thermal Oxidizer39 TO-4 TO4 Thermal Oxidizer42 Fugitives FUG Fugitives

    43 MSS Floating Roof Landing 250 KBBL Tanks SSM SSM Emissions

    44 MSS Misc SSM SSM Emissions

    43 MSS Floating Roof Landing 50 KBBL Tanks SSM SSM Emissions

    46 MSS BlowdownsFL1-

    FL3OVHD-SSM

    FL1-FL3 Stabilizer Overhead SSM Gas

    46 MSS BlowdownsFL1-

    FL3CRYO-SSM

    FL1-FL3 Cryo Blowdown SSM Gas

    47 Haul Road Fugitives ROAD Haul Road Fugitives48 Amine Sweetener 1 AU1 Amine Sweetener 149 Amine Sweetener 2 AU2 Amine Sweetener 250 Amine Sweetener 3 AU3 Amine Sweetener 351 Amine Sweetener 4 AU4 Amine Sweetener 4

    52 Amine Make Up Tank Insignificant source moved to table 2-B53 Gun Barrel Tank GBS1 Gunbarrel Tank54 Produced Water Tanks PWTK1 Produced Water Tank 154 Produced Water Tanks PWTK2 Produced Water Tank 255 Slop Oil Tank SOTK1 Slop Oil Tank

    SOTL Slop Oil Truck Loading

    Unit numbers must correspond to unit numbers in the previous permit unless a complete cross reference table of all units in both permits is provided. This table completes that requirement.

    Cross reference table of all units in both permits

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    2019 N/A

    2019 SHTR1

    2019 N/A

    2019 SHTR2

    2019 N/A

    2019 SHTR3

    TBD N/A

    TBD SHTR4

    TBD N/A

    TBD SHTR5

    TBD N/A

    TBD SHTR6

    TBD SHTR7-CAT

    TBD SHTR7

    TBD SHTR8-CAT

    TBD SHTR8

    TBD SHTR9-CAT

    TBD SHTR9

    TBD SHTR10-CAT

    TBD SHTR10

    TBD SHTR11-CAT

    TBD SHTR11

    2019 N/A

    TBD CHTR1

    58.93 MMBtu/hr

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A58.93 MMBtu/hr

    58.93 MMBtu/hr

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A

    SHTR2Stabilization Hot Oil

    Heater (58.93 MMBtu/hr)

    THM SHO5000 PK-6020H-6022

    SHTR1Stabilization Hot Oil

    Heater (58.93 MMBtu/hr)

    THM SHO5000 PK-6010H-6012

    Table 2-A: Regulated Emission SourcesUnit and stack numbering must correspond throughout the application package. If applying for a NOI under 20.2.73 NMAC, equipment exemptions under 2.72.202 NMAC do not apply.

    Unit Number1 Source Description Make Model # Serial #

    Manufact-urer's Rated

    Capacity3

    (Specify Units)

    Requested Permitted Capacity3

    (Specify Units)

    Date of Manufacture2

    Controlled by Unit #

    Source Classi- fication Code

    (SCC)For Each Piece of Equipment, Check One

    RICE Ignition Type (CI, SI, 4SLB, 4SRB,

    2SLB)4

    Replacing Unit No.Date of

    Construction/ Reconstruction2

    Emissions vented to Stack #

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A58.93 MMBtu/hr

    SHTR4Stabilization Hot Oil

    Heater(58.93 MMBtu/hr)

    THM SHO5000 TBD

    SHTR3Stabilization Hot Oil

    Heater (58.93 MMBtu/hr)

    THM SHO5000 PK-6030H-6032

    58.93 MMBtu/hr

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    58.93 MMBtu/hr 31000403

    SHTR6Stabilization Hot Oil

    Heater (58.93 MMBtu/hr)

    THM SHO5000 TBD

    SHTR5Stabilization Hot Oil

    Heater (58.93 MMBtu/hr)

    THM SHO5000 TBD N/A58.93 MMBtu/hr

    SHTR8

    Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    THM SHO5000 TBD

    SHTR7

    Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    THM SHO5000 TBD

    58.93 MMBtu/hr

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A58.93 MMBtu/hr

    SHTR10

    Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    THM SHO5000 TBD

    SHTR9

    Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    THM SHO5000 TBD

    58.93 MMBtu/hr

    58.93 MMBtu/hr

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    SHTR11

    Stabilization Hot Oil Heater w/ SCR

    catalyst(58.93 MMBtu/hr)

    THM SHO5000 TBD

    CHTR1 Cryo Hot Oil Heater (94.54 MMBtu/hr) THM TBDPK-6110H-6112

    58.93 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A58.93 MMBtu/hr

    94.54 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A94.54 MMBtu/hr

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 5/29/2020 11:29 AM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    Table 2-A: Regulated Emission SourcesUnit and stack numbering must correspond throughout the application package. If applying for a NOI under 20.2.73 NMAC, equipment exemptions under 2.72.202 NMAC do not apply.

    Unit Number1 Source Description Make Model # Serial #

    Manufact-urer's Rated

    Capacity3

    (Specify Units)

    Requested Permitted Capacity3

    (Specify Units)

    Date of Manufacture2

    Controlled by Unit #

    Source Classi- fication Code

    (SCC)For Each Piece of Equipment, Check One

    RICE Ignition Type (CI, SI, 4SLB, 4SRB,

    2SLB)4

    Replacing Unit No.Date of

    Construction/ Reconstruction2

    Emissions vented to Stack #

    TBD NA

    TBD CHTR2

    TBD CHTR3-CAT

    TBD CHTR3

    TBD CHTR4-CAT

    TBD CHTR4

    TBD N/A

    TBD RHTR1

    TBD N/A

    TBD RHTR2

    TBD N/A

    TBD RHTR3

    TBD N/A

    TBD RHTR4

    2018 N/A

    2019 FL1

    2019 N/A

    2019 FL2

    TBD N/A

    TBD FL3

    N/A FL1-FL3

    N/A FL1-FL3OVHD-N/A FL1-FL3

    N/A FL1-FL3CRYO-2019 N/A

    2019 IFR1

    RHTR4 Regen Heater(35.25 MMBtu/hr) THM SHO2500 TBD35.25

    MMBtu/hr35.25

    MMBtu/hr 31000405 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    CHTR4Cryo Hot Oil Heater

    w/ SCR Catalyst(94.54 MMBtu/hr)

    THM TBD TBD

    CHTR2 Cryo Hot Oil Heater (94.54 MMBtu/hr) THM TBD TBD

    94.54 MMBtu/hr

    94.54 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    94.54 MMBtu/hr

    94.54 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    94.54 MMBtu/hr 31000403

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/ACHTR3Cryo Hot Oil Heater

    w/ SCR Catalyst(94.54 MMBtu/hr)

    THM TBD TBD 94.54 MMBtu/hr

    RHTR2 Regen Heater(35.25 MMBtu/hr) THM SHO2500 TBD

    RHTR1 Regen Heater (35.25 MMBtu/hr) THM SHO2500 H-3132

    35.25 MMBtu/hr

    35.25 MMBtu/hr 31000405

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    35.25 MMBtu/hr 31000405

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A35.25 MMBtu/hr

    35.25 MMBtu/hr 31000405

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/ARHTR3 Regen Heater(35.25 MMBtu/hr) THM SHO2500 TBD35.25

    MMBtu/hr

    Zeeco, Inc. N/A FS 6810S.O # 35284

    FL2Cryo

    Flare 2 (Dual Tip Flare)

    Zeeco, Inc. N/A FS 6960S.O # 38126

    20MMscfd

    20MMscfd

    FL1Stabilizer

    Flare 1(Dual Tip Flare)

    20MMscfd 31000160

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    20MMscfd 31000160

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    IFR1 Oil Storage Tank 1(50,000 bbl)Advance

    Tank N/A TK-4201

    FL3Backup SSM/Emergency

    Flare 3 (Dual Tip Flare)

    Zeeco, Inc. N/A TBD

    FL1-FL3OVHD-

    SSM

    FL1-FL3 Stabilizer Overhead SSM Gas Zeeco, Inc. N/A N/A

    FL1-FL3CRYO-

    SSM

    FL1-FL3 Cryo Blowdown SSM Gas Zeeco, Inc. N/A N/A

    50,000 bbl 50,000 bbl 40400331 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    20MMscfd 31000160

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A20MMscfd

    250MMscfd

    250MMscfd 31000160

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    250MMscfd

    250MMscfd 31000160

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    Form Revision: 5/3/2016 Table 2-A: Page 2 Printed 5/29/2020 11:29 AM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    Table 2-A: Regulated Emission SourcesUnit and stack numbering must correspond throughout the application package. If applying for a NOI under 20.2.73 NMAC, equipment exemptions under 2.72.202 NMAC do not apply.

    Unit Number1 Source Description Make Model # Serial #

    Manufact-urer's Rated

    Capacity3

    (Specify Units)

    Requested Permitted Capacity3

    (Specify Units)

    Date of Manufacture2

    Controlled by Unit #

    Source Classi- fication Code

    (SCC)For Each Piece of Equipment, Check One

    RICE Ignition Type (CI, SI, 4SLB, 4SRB,

    2SLB)4

    Replacing Unit No.Date of

    Construction/ Reconstruction2

    Emissions vented to Stack #

    2019 N/A

    2019 IFR2

    2019 N/A

    2019 IFR3

    2019 N/A

    2019 IFR4

    TBD N/A

    TBD IFR5

    TBD N/A

    TBD IFR6

    TBD N/A

    TBD IFR7

    TBD N/A

    TBD IFR8

    TBD N/A

    TBD ECD1

    2019 N/A

    2019 TO1

    TBD N/A

    TBD TO2

    TBD N/A

    TBD TO3

    TBD N/A

    TBD TO4

    TBD N/A

    TBD FUG

    TBD N/A

    TBD SSM

    25 MMbtu/hr

    25 MMbtu/hr

    50,000 bbl 40400331 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A50,000 bbl

    IFR3 Oil Storage Tank 3(50,000 bbl)Advance

    Tank N/A TK-4203

    IFR2 Oil Storage Tank 2(50,000 bbl)Advance

    Tank N/A TK-4202

    IFR7 Oil Storage Tank 7(250,000 bbl) TBD

    50,000 bbl 50,000 bbl 40400331 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    IFR5 Oil Storage Tank 5(250,000 bbl) TBD N/A TBD

    IFR6 Oil Storage Tank 6(250,000 bbl) TBD N/A TBD

    50,000 bbl 40400331

    250,000 bbl 250,000 bbl 40400331

    TO2 Thermal Oxidizer Zeeco, Inc. N/A TBD

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A50,000 bbl

    250,000 bbl 250,000 bbl 40400331 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    N/A N/A 31000209

    IFR4 Oil Storage Tank 4(50,000 bbl)Advance

    Tank

    N/A TBD

    N/A 31088811

    25 MMbtu/hr

    25 MMbtu/hr 31000209

    N/A TK-4204

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    31000209 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/ATO1 Thermal Oxidizer Zeeco, Inc. N/A TO-6980SO # 35595

    ECD1 Combustor Zeeco, Inc. N/A TBD

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    N/A 31088811 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/AN/A

    N/A

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    25 MMbtu/hr

    25 MMbtu/hr 31000209

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    25 MMbtu/hr

    25 MMbtu/hr 31000209

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    TO4 Thermal Oxidizer Zeeco, Inc. N/A TBD

    N/A

    FUG Fugitives N/A N/A N/A

    TO3 Thermal Oxidizer Zeeco, Inc. N/A TBD

    SSM SSM Emissions N/A N/A

    IFR8 Oil Storage Tank 8(250,000 bbl) TBD N/A TBD 250,000 bbl 250,000 bbl 40400331 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    250,000 bbl 250,000 bbl 40400331 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    N/A N/A

    Form Revision: 5/3/2016 Table 2-A: Page 3 Printed 5/29/2020 11:29 AM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    Table 2-A: Regulated Emission SourcesUnit and stack numbering must correspond throughout the application package. If applying for a NOI under 20.2.73 NMAC, equipment exemptions under 2.72.202 NMAC do not apply.

    Unit Number1 Source Description Make Model # Serial #

    Manufact-urer's Rated

    Capacity3

    (Specify Units)

    Requested Permitted Capacity3

    (Specify Units)

    Date of Manufacture2

    Controlled by Unit #

    Source Classi- fication Code

    (SCC)For Each Piece of Equipment, Check One

    RICE Ignition Type (CI, SI, 4SLB, 4SRB,

    2SLB)4

    Replacing Unit No.Date of

    Construction/ Reconstruction2

    Emissions vented to Stack #

    TBD N/A

    TBD ROAD

    TBD TO1

    TBD TO1

    TBD TO2

    TBD TO2

    TBD TO3

    TBD TO3

    TBD TO4

    TBD TO4

    2019 ECD1

    2019 ECD1

    2019 ECD1

    2019 ECD1

    2019 ECD1

    2019 ECD1

    2019 ECD1

    2019 ECD1

    N/A ECD1

    N/A SOTL

    TBD N/A

    TBD GEN1

    TBD N/A

    TBD GEN2

    TBD N/A

    TBD GEN3

    TBD N/A

    TBD GEN4

    N/A N/AN/A N/A

    N/A N/AESTCOMP1-1717 Electric Stabilizer

    Compressors N/A N/A N/A N/A N/A N/A Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    ROAD Haul Road Fugitives N/A N/A N/A N/A N/A 31088811 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    PWTK2 Produced Water Tank 2Alliance Tank

    Services N/A TK-7006

    PWTK1 Produced Water Tank 1Alliance Tank

    Services N/A TK-7005

    750 bbl 750 bbl 40400315 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    750 bbl 40400315 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A750 bbl

    23 bbl/day 23 bbl/day 40400250 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    500 bbl 500 bbl 40400311 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    SOTL Slop Oil Truck Loading TBD N/A N/A

    AU2 Amine Sweetener 2 N/A N/A N/A

    AU3 Amine Sweetener 3 N/A N/A N/A

    SOTK1 Slop Oil Tank Alliance Tank Services N/A TK-6895

    AU4 Amine Sweetener 4 N/A N/A

    31000305 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A250 MMSCFD

    AU1 Amine Sweetener 1 N/A N/A N/A

    250 MMSCFD

    250 MMSCFD 31000305

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    1,000 bbl 31000506 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A1,000 bblGBS1 Gunbarrel Tank Angelina Tank N/A TK-7001

    N/A 250 MMSCFD250

    MMSCFD 31000305 Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A

    N/A N/A

    250 MMSCFD 31000305

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit To Be Modified � To be Replaced

    N/A N/A250 MMSCFD

    250 MMSCFD

    4SLB N/A

    GEN2 Emergency Generator Caterpillar G3520H TBD 3063 HP 3063 HP 20200254 Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    4SLB N/A

    GEN1 Emergency Generator Caterpillar G3520H TBD 3063 HP 3063 HP 20200254 Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    4SLB N/A

    GEN4 Emergency Generator Caterpillar G3520H TBD 3063 HP 3063 HP 20200254 Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    4SLB N/A

    GEN3 Emergency Generator Caterpillar G3520H TBD 3063 HP 3063 HP 20200254 Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    Form Revision: 5/3/2016 Table 2-A: Page 4 Printed 5/29/2020 11:29 AM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    Table 2-A: Regulated Emission SourcesUnit and stack numbering must correspond throughout the application package. If applying for a NOI under 20.2.73 NMAC, equipment exemptions under 2.72.202 NMAC do not apply.

    Unit Number1 Source Description Make Model # Serial #

    Manufact-urer's Rated

    Capacity3

    (Specify Units)

    Requested Permitted Capacity3

    (Specify Units)

    Date of Manufacture2

    Controlled by Unit #

    Source Classi- fication Code

    (SCC)For Each Piece of Equipment, Check One

    RICE Ignition Type (CI, SI, 4SLB, 4SRB,

    2SLB)4

    Replacing Unit No.Date of

    Construction/ Reconstruction2

    Emissions vented to Stack #

    N/A N/AN/A N/AN/A N/AN/A N/AN/A N/AN/A N/A

    N/A N/A

    N/A N/A1 Unit numbers must correspond to unit numbers in the previous NOI unless a complete cross reference table of all units in both NOIs is provided.

    2 Specify dates required to determine regulatory applicability.

    3 To properly account for power conversion efficiencies, generator set rated capacity shall be reported as the rated capacity of the engine in horsepower, not the kilowatt capacity of the generator set.

    4 "4SLB" means four stroke lean burn engine, "4SRB" means four stroke rich burn engine, "2SLB" means two stroke lean burn engine, "CI" means compression ignition, and "SI" means spark ignitio

    N/A N/A

    MOL1-4 4 Molecular Sieve Dehydrators N/A N/A N/A N/A N/A N/A Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    N/A N/A

    CRYO1-4 4 Cryogenic Trains N/A N/A N/A N/A N/A N/A Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    EIACOMP1-5

    5 Electric Instrument Air Compressors N/A N/A N/A N/A N/A N/A

    Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    N/A N/A

    N/A N/AMalfunction Malfunction Emissions N/A N/A N/A N/A N/A 31088811 Existing (unchanged) � To be Removed New/Additional � Replacement Unit � To Be Modified � To be Replaced

    Form Revision: 5/3/2016 Table 2-A: Page 5 Printed 5/29/2020 11:29 AM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    N/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBDN/A N/A Units with PTE < 0.5 tpy TBDN/A N/A 20.2.72.202.B.5 TBD

    N/A N/A Units with PTE < 0.5 tpy TBD

    2 Specify date(s) required to determine regulatory applicability.

    1 Insignificant activities exempted due to size or production rate are defined in 20.2.70.300.D.6, 20.2.70.7.Q NMAC, and the NMED/AQB List of Insignificant Activities, dated September 15, 2008. Emissions from these insignificant activities do not need to be reported, unless specifically requested.

    55 Utility Water Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    VTank01 Varsol Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    Table 2-B: Insignificant Activities 1 (20.2.70 NMAC) OR Exempted Equipment (20.2.72 NMAC) All 20.2.70 NMAC (Title V) applications must list all Insignificant Activities in this table. All 20.2.72 NMAC applications must list Exempted Equipment in this table. If equipment listed on this table is exempt under 20.2.72.202.B.5, include emissions calculations and emissions totals for 202.B.5 "similar functions" units, operations, and activities in Section 6, Calculations. Equipment and activities exempted under 20.2.72.202 NMAC may not necessarily be Insignificant under 20.2.70 NMAC (and vice versa). Unit & stack numbering must be consistent throughout the application package. Per Exemptions Policy 02-012.00 (see http://www.env.nm.gov/aqb/permit/aqb_pol.html ), 20.2.72.202.B NMAC Exemptions do not apply, but 20.2.72.202.A NMAC exemptions do apply to NOI facilities under 20.2.73 NMAC. List 20.2.72.301.D.4 NMAC Auxiliary Equipment for Streamline applications in Table 2-A. The List of Insignificant Activities (for TV) can be found online at http://www.env.nm.gov/aqb/forms/InsignificantListTitleV.pdf . TV sources may elect to enter both TV Insignificant Activities and Part 72 Exemptions on this form.

    Unit Number Source Description ManufacturerModel No. Max Capacity List Specific 20.2.72.202 NMAC Exemption (e.g. 20.2.72.202.B.5)

    Date of Manufacture

    /Reconstruction2 For Each Piece of Equipment, Check OncSerial No. Capacity Units Insignificant Activity citation (e.g. IA List Item #1.a)

    Date of Installation /Construction2

    50

    48B 1000 bbl Raw Water Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    Amine Makeup Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    49 1000 bbl Demineralized Water Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    51B 100 bbl Lube Oil Make-Up Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    FFT 1000 bbl Firefighting Foam Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    51A 100 bbl Lube Oil Make-Up Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    48A 1000 bbl Raw Water Tank TBD Existing (unchanged) To be Removed New/Additional Replacement Unit To Be Modified To be Replaced

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    FL2 Flare 1 TBD VOC, HAP Plant Inlet & SSM Activities 98% Mnf. Guarantee

    FL1 Flare 2 TBD VOC, HAP Plant Inlet & SSM Activities 98% Mnf. Guarantee

    FL3 Flare 3 TBD VOC, HAP Plant Inlet & SSM Activities 98% Mnf. Guarantee

    ECD1 Combustor TBD VOC, HAP GBS1, PWTK1-PWTK2, SOTK1,SOTL 99% Mnf. Guarantee

    TO1 Thermal Oxidizer TBD VOC, HAP AU1 99% Mnf. Guarantee

    TO2 Thermal Oxidizer TBD VOC, HAP AU2 99% Mnf. Guarantee

    TO3 Thermal Oxidizer TBD VOC, HAP AU3 99% Mnf. Guarantee

    TO4 Thermal Oxidizer TBD VOC, HAP AU4 99% Mnf. Guarantee

    SHTR7-CAT SCR Catalytic Reduction TBD NOx SHTR7-CAT NOx - 75% Mnf. Guarantee

    SHTR8-CAT SCR Catalytic Reduction TBD NOx SHTR8-CAT NOx - 75% Mnf. Guarantee

    SHTR9-CAT SCR Catalytic Reduction TBD NOx SHTR9-CAT NOx - 75% Mnf. Guarantee

    SHTR10-CAT SCR Catalytic Reduction TBD NOx SHTR10-CAT NOx - 75% Mnf. Guarantee

    SHTR11-CAT SCR Catalytic Reduction TBD NOx SHTR11-CAT NOx - 75% Mnf. Guarantee

    CHTR3-CAT SCR Catalytic Reduction TBD NOx CHTR3-CAT NOx - 80% Mnf. Guarantee

    CHTR4-CAT SCR Catalytic Reduction TBD NOx CHTR4-CAT NOx - 80% Mnf. Guarantee

    1 List each control device on a separate line. For each control device, list all emission units controlled by the control device.

    Table 2-C: Emissions Control EquipmentUnit and stack numbering must correspond throughout the application package. Only list control equipment for TAPs if the TAP’s maximum uncontrolled emissions rate is over its respective threshold as listed in 20.2.72 NMAC, Subpart V, Tables A and B. In accordance with 20.2.72.203.A(3) and (8) NMAC, 20.2.70.300.D(5)(b) and (e) NMAC, and 20.2.73.200.B(7) NMAC, the permittee shall report all control devices and list each pollutant controlled by the control device regardless if the applicant takes credit for the reduction in emissions.

    Control Equipment Unit

    No.Control Equipment Description Date Installed Controlled Pollutant(s)

    Controlling Emissions for Unit Number(s)1

    Efficiency(% Control by

    Weight)

    Method used to Estimate

    Efficiency

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yrSHTR1 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR2 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR3 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR4 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR5 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR6 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR7 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR8 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR9 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR10 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR11 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -CHTR1 0.70 2.77 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -CHTR2 0.70 2.77 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -CHTR3 0.70 2.77 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -CHTR4 0.70 2.77 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -RHTR1 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -RHTR2 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -RHTR3 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -RHTR4 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -

    FL1-FL3² 1.40 6.14 2.80 12.26 0.29 1.29 0.00 0.00 0.08 0.33 0.08 0.33 0.08 0.33 - - - -

    FL1-FL3OVHD-

    SSMFL1-

    FL3CRYO-SSMIFR1 -- -- -- -- 0.98 4.27 -- -- -- -- -- -- -- -- - - - -IFR2 -- -- -- -- 0.98 4.27 -- -- -- -- -- -- -- -- - - - -IFR3 -- -- -- -- 0.98 4.27 -- -- -- -- -- -- -- -- - - - -IFR4 -- -- -- -- 0.98 4.27 -- -- -- -- -- -- -- -- - - - -IFR5 -- -- -- -- 2.59 11.36 -- -- -- -- -- -- -- -- - - - -IFR6 -- -- -- -- 2.59 11.36 -- -- -- -- -- -- -- -- - - - -IFR7 -- -- -- -- 2.59 11.36 -- -- -- -- -- -- -- -- - - - -IFR8 -- -- -- -- 2.59 11.36 -- -- -- -- -- -- -- -- - - - -

    ECD1² 0.03 0.11 0.05 0.22 0.01 0.03 0.00 0.00 0.00 0.01 0.00 0.01 0.00 0.01 - - - -

    H2S Lead

    Not operating during normal operating conditions

    Not operating during normal operating conditions

    Table 2-D: Maximum Emissions (under normal operating conditions)Maximum Emissions are the emissions at maximum capacity and prior to (in the absence of) pollution control, emission-reducing process equipment, or any other emission reduction. Calculate the hourly emissions using the worst case hourly emissions for each pollutant. For each pollutant, calculate the annual emissions as if the facility were operating at maximum plant capacity without pollution controls for 8760 hours per year, unless otherwise approved by the Department. List Hazardous Air Pollutants (HAP) & Toxic Air Pollutants (TAPs) in Table 2-I. Unit & stack numbering must be consistent throughout the application package. Fill all cells in this table with the emission numbers or a "-" symbol. A “-“ symbol indicates that emissions of this pollutant are not expected. Numbers shall be expressed to at least 2 decimal points (e.g. 0.41, 1.41, or 1.41E-4).

    Unit No. NOx CO VOC SOx PM1 PM102 PM2.52

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yrH2S Lead

    Table 2-D: Maximum Emissions (under normal operating conditions)Maximum Emissions are the emissions at maximum capacity and prior to (in the absence of) pollution control, emission-reducing process equipment, or any other emission reduction. Calculate the hourly emissions using the worst case hourly emissions for each pollutant. For each pollutant, calculate the annual emissions as if the facility were operating at maximum plant capacity without pollution controls for 8760 hours per year, unless otherwise approved by the Department. List Hazardous Air Pollutants (HAP) & Toxic Air Pollutants (TAPs) in Table 2-I. Unit & stack numbering must be consistent throughout the application package. Fill all cells in this table with the emission numbers or a "-" symbol. A “-“ symbol indicates that emissions of this pollutant are not expected. Numbers shall be expressed to at least 2 decimal points (e.g. 0.41, 1.41, or 1.41E-4).

    Unit No. NOx CO VOC SOx PM1 PM102 PM2.52

    TO1² 0.33 1.45 0.20 0.89 0.36 1.58 0.00 0.00 0.18 0.79 0.18 0.79 0.18 0.79 - - - -TO2² 0.33 1.45 0.20 0.89 0.36 1.58 0.00 0.00 0.18 0.79 0.18 0.79 0.18 0.79 - - - -TO3² 0.33 1.45 0.20 0.89 0.36 1.58 0.00 0.00 0.18 0.79 0.18 0.79 0.18 0.79 - - - -TO4² 0.33 1.45 0.20 0.89 0.36 1.58 0.00 0.00 0.18 0.79 0.18 0.79 0.18 0.79 - - - -FUG -- -- -- -- 33.82 148.15 -- -- -- -- -- -- -- -- - - - -SSM -- -- -- -- -- 10.00 -- -- -- -- -- -- -- -- - - - -

    ROAD -- -- -- -- -- -- -- -- 2.76 0.01 0.70 0.00 0.07 0.00 - - - -AU1 -- -- -- -- 80.16 351.11 -- -- -- -- -- -- -- -- - - - -AU2 -- -- -- -- 80.16 351.11 -- -- -- -- -- -- -- -- - - - -AU3 -- -- -- -- 80.16 351.11 -- -- -- -- -- -- -- -- - - - -AU4 -- -- -- -- 80.16 351.11 -- -- -- -- -- -- -- -- - - - -GBS1 -- -- -- -- 15.80 69.21 -- -- -- -- -- -- -- -- - - - -

    PWTK1 -- -- -- -- 2.68 11.75 -- -- -- -- -- -- -- -- - - - -PWTK2 -- -- -- -- 2.68 11.75 -- -- -- -- -- -- -- -- - - - -SOTK1 -- -- -- -- 57.70 252.73 -- -- -- -- -- -- -- -- - - - -SOTL -- -- -- -- 53.34 0.58 -- -- -- -- -- -- -- -- - - - -GEN1 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -GEN2 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -GEN3 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -GEN4 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -Totals 42.23 116.14 75.37 101.90 529.07 2012.37 2.99 12.42 13.85 45.45 11.79 45.45 11.16 45.45 - - - -

    ² Only includes pilot/purge gas/assist gas emissions, other emissions not considered normal operating conditions.

    1Condensable Particulate Matter: Include condensable particulate matter emissions for PM10 and PM2.5 if the source is a combustion source. Do not include condensable particulate matter for PM unless PM is set equal to PM10 and PM2.5. Particulate matter (PM) is not subject to an ambient air quality standard, but PM is a regulated air pollutant under PSD (20.2.74 NMAC) and Title V (20.2.70 NMAC).

    Form Revision: 5/3/2016 Table 2-A: Page 2 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yrSHTR1 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR2 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR3 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR4 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR5 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR6 1.73 6.89 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR7 0.43 1.73 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR8 0.43 1.73 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR9 0.43 1.73 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -

    SHTR10 0.43 1.73 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -SHTR11 0.43 1.73 1.06 4.21 0.41 1.65 0.14 0.63 0.48 2.12 0.48 2.12 0.48 2.12 - - - -CHTR1 3.47 13.83 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -CHTR2 3.47 13.83 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -CHTR3 0.70 2.77 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -CHTR4 0.70 2.77 1.70 6.75 0.67 2.65 0.23 1.00 0.77 3.39 0.77 3.39 0.77 3.39 - - - -RHTR1 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -RHTR2 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -RHTR3 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -RHTR4 1.04 4.12 0.63 2.52 0.25 0.99 0.09 0.37 0.29 1.27 0.29 1.27 0.29 1.27 - - - -

    FL1-FL3 1.40 6.14 2.80 12.26 0.29 1.29 0.00 0.00 0.08 0.33 0.08 0.33 0.08 0.33

    IFR1 -- -- -- -- 0.90 3.94 -- -- -- -- -- -- -- -- - - - -

    IFR2 -- -- -- -- 0.90 3.94 -- -- -- -- -- -- -- -- - - - -IFR3 -- -- -- -- 0.90 3.94 -- -- -- -- -- -- -- -- - - - -IFR4 -- -- -- -- 0.90 3.94 -- -- -- -- -- -- -- -- - - - -IFR5 -- -- -- -- 2.36 10.33 -- -- -- -- -- -- -- -- - - - -IFR6 -- -- -- -- 2.36 10.33 -- -- -- -- -- -- -- -- - - - -IFR7 -- -- -- -- 2.36 10.33 -- -- -- -- -- -- -- -- - - - -IFR8 -- -- -- -- 2.36 10.33 -- -- -- -- -- -- -- -- - - - -ECD1 0.44 1.17 0.88 2.34 1.34 3.53 0.00 0.00 0.02 0.03 0.02 0.03 0.02 0.03 - - - -TO1 3.56 15.59 2.17 9.49 0.85 3.81 0.00 0.00 0.22 0.97 0.22 0.97 0.22 0.97 - - - -TO2 3.56 15.59 2.17 9.49 0.85 3.81 0.00 0.00 0.22 0.97 0.22 0.97 0.22 0.97 - - - -TO3 3.56 15.59 2.17 9.49 0.85 3.81 0.00 0.00 0.22 0.97 0.22 0.97 0.22 0.97 - - - -TO4 3.56 15.59 2.17 9.49 0.85 3.81 0.00 0.00 0.22 0.97 0.22 0.97 0.22 0.97 - - - -

    Table 2-E: Requested Allowable EmissionsUnit & stack numbering must be consistent throughout the application package. Fill all cells in this table with the emission numbers or a "-" symbol. A “-“ symbol indicates that emissions of this pollutant are not expected. Numbers shall be expressed to at least 2 decimal points (e.g. 0.41, 1.41, or 1.41E-4).

    Unit No. NOx CO VOC SOx PM1 PM101 PM2.51 H2S Lead

    Form Revision: 6/14/2019 Table 2-E: Page 1 Printed 5/28/2020 8:27 PM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr

    Table 2-E: Requested Allowable EmissionsUnit & stack numbering must be consistent throughout the application package. Fill all cells in this table with the emission numbers or a "-" symbol. A “-“ symbol indicates that emissions of this pollutant are not expected. Numbers shall be expressed to at least 2 decimal points (e.g. 0.41, 1.41, or 1.41E-4).

    Unit No. NOx CO VOC SOx PM1 PM101 PM2.51 H2S Lead

    FUG -- -- -- -- 16.44 72.00 -- -- -- -- -- -- -- -- - - - -

    ROAD -- -- -- -- -- -- -- -- 2.76 0.01 0.70 0.00 0.07 0.00 - - - -AU1AU2AU3AU4

    GBS1PWTK1PWTK2SOTK1SOTLGEN1 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -GEN2 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -GEN3 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -GEN4 3.38 0.17 12.69 0.63 4.54 0.23 0.04 0.00 0.18 0.01 0.18 0.01 0.18 0.01 - - - -

    Malfunction - - - - - 10.00 - - - - - - - - - - - -

    Totals 54.6 170.0 84.1 138.4 60.9 192.7 3.0 12.4 14.0 46.2 12.0 46.2 11.3 46.2 - - - -

    2 For all pollutants except VOC/HAP, the hourly emission rate excludes the generators and overhead SSM stream as they cannot occur at the same time and the cryo SSM stream has a higher emission rate. For VOC, the overhead SSM stream is included with the highest hourly rate. For HAP, the generators have the highest hourly rate.

    Emissions are represented at TO3

    1 Condensable Particulate Matter: Include condensable particulate matter emissions for PM10 and PM2.5 if the source is a combustion source. Do not include condensable particulate matter for PM unless PM is set equal to PM10 and PM2.5. Particulate matter (PM) is not subject to an ambient air quality standard, but it is a regulated air pollutant under PSD (20.2.74 NMAC) and Title V (20.2.70 NMAC).

    Emissions are represented at TO4

    Emissions are represented at ECD1

    Emissions are represented at ECD1Emissions are represented at ECD1

    Emissions are represented at TO1Emissions are represented at TO2

    Emissions are represented at ECD1Emissions are represented at ECD1

    Form Revision: 6/14/2019 Table 2-E: Page 2 Printed 5/28/2020 8:27 PM

  • XTO Energy Inc. Cowboy CDP May 2020: Revision 1

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yrSSM -- -- -- -- -- 10.00 -- -- -- -- -- -- -- -- -- -- -- --FL1-

    FL3OVHD-SSM

    165.59 3.31 330.57 6.61 1,093.54 21.87 0.00 0.00 8.94 0.18 8.94 0.18 8.94 0.18 -- -- -- --

    FL1-FL3CRYO-

    SSM323.31 6.47 645.44 12.91 517.03 10.34 0.00 0.00 54.81 1.10 54.81 1.10 54.81 1.10 -- -- -- --

    Totals 488.90 9.78 976.02 19.52 1610.57 42.21 0.00 0.00 63.75 1.28 63.75 1.28 63.75 1.28 - - - - 1 For instance, if the short term steady-state Table 2-E emissions are 5 lb/hr and the SSM rate is 12 lb/hr, enter 7 lb/hr in this table. If the annual steady-state Table 2-E emissions are 21.9 TPY, and the number of scheduled SSM events result in annual emissions of 31.9 TPY, enter 10.0 TPY in the table below.2 Condensable Particulate Matter: Include condensable particulate matter emissions for PM10 and PM2.5 if the source is a combustion source. Do not include condensable particulate matter for PM unless PM is set equal to PM10 and PM2.5. Particulatmatter (PM) is not subject to an ambient air quality standard, but it is a regulated air pollutant under PSD (20.2.74 NMAC) and Title V (20.2.70 NMAC).

    Table 2-F: Additional Emissions during Startup, Shutdown, and Routine Maintenance (SSM) This table is intentionally left blank since all emissions at this facility due to routine or predictable startup, shutdown, or scehduled maintenance are no higher than those listed in Table 2-E and a malfunction emission

    limit is not already permitted or requested. If you are required to report GHG emissions as described in Section 6a, include any GHG emissions during Startup, Shutdown, and/or Scheduled Maintenance (SSM) in Table 2-P. Provide an explanations of SSM emissions in Section 6 and 6a.All applications for facilities that have emissions during routine our predictable startup, shutdown or scheduled maintenance (SSM)1, including NOI applications, must include in this table the Maximum Emissions during routine or predictable startup, shutdown and scheduled maintenance (20.2.7 NMAC, 20.2.72.203.A.3 NMAC, 20.2.73.200.D.2 NMAC). In Section 6 and 6a, provide emissions calculations for all SSM emissions reported in this table. Refer to "Guidance for Submittal of Startup, Shutdown, Maintenance Emissions in Permit Applications (https://www.env.nm.gov/aqb/permit/aqb pol.html) for more detailed instructions. Numbers shall be expressed to at least 2 decimal points (e.g. 0.41, 1.41, or 1.41E-4).

    Unit No.NOx CO VOC SOx PM2 PM102 PM2.52 H2S Lead

    Form Revision: 6/14/2019 Table 2-F: Page 1 Printed 5/28/2020 8:27 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr

    N/A - This facility does not have Special Stacks

    Totals:

    Table 2-G: Stack Exit and Fugitive Emission Rates for Special Stacks I have elected to leave this table blank because this facility does not have any stacks/vents that split emissions from a single source or combine emissions from more than one source listed in table 2-A. Additionally, the emission rates of all stacks match the Requested allowable emission rates stated in Table 2-E.

    Use this table to list stack emissions (requested allowable) from split and combined stacks. List Toxic Air Pollutants (TAPs) and Hazardous Air Pollutants (HAPs) in Table 2-I. List all fugitives that are associated with the normal, routine, and non-emergency operation of the facility. Unit and stack numbering must correspond throughout the application package. Refer to Table 2-E for instructions on use of the “-“ symbol and on significant figures.

    Stack No.Serving Unit

    Number(s) from Table 2-A

    NOx CO VOC SOx PM PM10 PM2.5 H2S or Lead

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Rain Caps Height Above Temp. Moisture by Velocity

    (Yes or No) Ground (ft) (F) (acfs) (dscfs) Volume (%) (ft/sec)

    SHTR1 SHTR1 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR2 SHTR2 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR3 SHTR3 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR4 SHTR4 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR5 SHTR5 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR6 SHTR6 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR7 SHTR7 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR8 SHTR8 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR9 SHTR9 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR10 SHTR10 V No 33.0 488 441 NA 0 35.1 4.0

    SHTR11 SHTR11 V No 33.0 488 441 NA 0 35.1 4.0

    CHTR1 CHTR1 V No 76.9 599 820 NA 0 65.3 4.0

    CHTR2 CHTR2 V No 76.9 599 820 NA 0 65.3 4.0

    CHTR3 CHTR3 V No 76.9 599 820 NA 0 65.3 4.0

    CHTR4 CHTR4 V No 76.9 599 820 NA 0 65.3 4.0

    RHTR1 RHTR1 V No 28.7 470 292 NA 0 52.3 2.7

    RHTR2 RHTR2 V No 28.7 470 292 NA 0 52.3 2.7

    RHTR3 RHTR3 V No 28.7 470 292 NA 0 52.3 2.7

    RHTR4 RHTR4 V No 28.7 470 292 NA 0 52.3 2.7

    FL2 FL2 V No 130.0 1832 139 NA 0 65.6 0.4

    FL1 FL1 V No 170.0 1832 139 NA 0 65.6 0.7

    FL3 FL3 V No 170.0 1832 139 NA 0 65.6 0.7

    Table 2-H: Stack Exit ConditionsUnit and stack numbering must correspond throughout the application package. Include the stack exit conditions for each unit that emits from a stack, including blowdown venting parameters and tank emissions.

    Stack Number

    Serving Unit Number(s) from Table 2-A

    Orientation (H-Horizontal

    V=Vertical)

    Flow RateInside

    Diameter (ft)

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    Rain Caps Height Above Temp. Moisture by Velocity

    (Yes or No) Ground (ft) (F) (acfs) (dscfs) Volume (%) (ft/sec)

    Table 2-H: Stack Exit ConditionsUnit and stack numbering must correspond throughout the application package. Include the stack exit conditions for each unit that emits from a stack, including blowdown venting parameters and tank emissions.

    Stack Number

    Serving Unit Number(s) from Table 2-A

    Orientation (H-Horizontal

    V=Vertical)

    Flow RateInside

    Diameter (ft)

    ECD1 ECD1 V No 40.0 1450 529 NA 0 39.5 8.4

    TO1 TO1 V No 58.0 1700 782.5 NA 0 58.6 4.1

    TO2 TO2 V No 58.0 1700 782.5 NA 0 58.6 4.1

    TO3 TO3 V No 58.0 1700 782.5 NA 0 58.6 4.1

    TO4 TO4 V No 58.0 1700 782.5 NA 0 58.6 4.1

    GEN1 GEN1 V No 14.0 736 260.3 NA 0 331.4 1.0

    GEN2 GEN2 V No 14.0 736 260.3 NA 0 331.4 1.0

    GEN3 GEN3 V No 14.0 736 260.3 NA 0 331.4 1.0

    GEN4 GEN4 V No 14.0 736 260.3 NA 0 331.4 1.0

    Form Revision: 5/3/2016 Table 2-A: Page 2 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr

    SHTR1 SHTR1 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR2 SHTR2 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR3 SHTR3 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR4 SHTR4 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR5 SHTR5 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR6 SHTR6 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR7 SHTR7 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR8 SHTR8 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR9 SHTR9 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR10 SHTR10 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    SHTR11 SHTR11 0.12 0.48 0.11 0.46 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.02 -- -- -- --

    CHTR1 CHTR1 0.19 0.76 0.18 0.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.03 -- -- -- --

    CHTR2 CHTR2 0.19 0.76 0.18 0.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.03 -- -- -- --

    CHTR3 CHTR3 0.19 0.76 0.18 0.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.03 -- -- -- --

    CHTR4 CHTR4 0.19 0.76 0.18 0.73 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 0.03 -- -- -- --

    RHTR1 RHTR1 0.07 0.28 0.07 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 -- -- -- --

    RHTR2 RHTR2 0.07 0.28 0.07 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 -- -- -- --

    RHTR3 RHTR3 0.07 0.28 0.07 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 -- -- -- --

    RHTR4 RHTR4 0.07 0.28 0.07 0.27 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.01 -- -- -- --

    FL1-FL3¹ FL1-FL3¹ 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -- -- -- --

    FL1-FL3¹ FL1-FL3OVHD- 15.67 0.31 6.81 0.14 5.15 0.10 3.16 0.06 0.00 0.00 0.56 0.01 0.00 0.00 -- -- -- --FL1-FL3¹ FL1-FL3CRYO- 1.62 0.03 1.45 0.03 0.16 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 -- -- -- --

    IFR1 IFR1 0.05 0.21 0.02 0.09 0.01 0.06 0.01 0.04 0.00 0.00 0.00 0.02 0.00 0.00 -- -- -- --

    IFR2 IFR2 0.05 0.21 0.02 0.09 0.01 0.06 0.01 0.04 0.00 0.00 0.00 0.02 0.00 0.00 -- -- -- --

    IFR3 IFR3 0.05 0.21 0.02 0.09 0.01 0.06 0.01 0.04 0.00 0.00 0.00 0.02 0.00 0.00 -- -- -- --

    IFR4 IFR4 0.05 0.21 0.02 0.09 0.01 0.06 0.01 0.04 0.00 0.00 0.00 0.02 0.00 0.00 -- -- -- --

    IFR5 IFR5 0.12 0.53 0.06 0.24 0.03 0.15 0.02 0.10 0.00 0.00 0.01 0.03 0.00 0.00 -- -- -- --

    IFR6 IFR6 0.12 0.53 0.06 0.24 0.03 0.15 0.02 0.10 0.00 0.00 0.01 0.03 0.00 0.00 -- -- -- --

    IFR7 IFR7 0.12 0.53 0.06 0.24 0.03 0.15 0.02 0.10 0.00 0.00 0.01 0.03 0.00 0.00 -- -- -- --

    IFR8 IFR8 0.12 0.53 0.06 0.24 0.03 0.15 0.02 0.10 0.00 0.00 0.01 0.03 0.00 0.00 -- -- -- --

    ECD1 ECD1 0.05 0.14 0.02 0.06 0.01 0.03 0.01 0.03 0.00 0.00 0.00 0.01 0.00 0.00 -- -- -- --

    Table 2-I: Stack Exit and Fugitive Emission Rates for HAPs and TAPsIn the table below, report the Potential to Emit for each HAP from each regulated emission unit listed in Table 2-A, only if the entire facility emits the HAP at a rate greater than or equal to one (1) ton per year For each such emission unit, HAPs shall be reported to the nearest 0.1 tpy. Each facility-wide Individual HAP total and the facility-wide Total HAPs shall be the sum of all HAP sources calculated to the nearest 0.1 ton per year. Per 20.2.72.403.A.1 NMAC, facilities not exempt [see 20.2.72.402.C NMAC] from TAP permitting shall report each TAP that has an uncontrolled emission rate in excess of its pounds per hour screening level specified in 20.2.72.502 NMAC. TAPs shall be reported using one more significant figure than the number of significant figures shown in the pound per hour threshold corresponding to the substance. Use the HAP nomenclature as it appears in Section 112 (b) of the 1990 CAAA and the TAP nomenclature as it listed in 20.2.72.502 NMAC. Include tank-flashing emissions estimates of HAPs in this table. For each HAP or TAP listed, fill all cells in this table with the emission numbers or a "-" symbol. A “-” symbol indicates that emissions of this pollutant are not expected or the pollutant is emitted in a quantity less than the threshold amounts described above.

    Provide Pollutant Name Here

    HAP or TAP

    Formaldehyde HAP or TAP

    H2SO4 HAP or TAP

    Ammonia HAP or TAPStack No. Unit No.(s)

    Total HAPs n-Hexane HAP or TAPBenzene

    HAP or TAPToluene

    HAP or TAPEthylbenzene

    HAP or TAPXylene

    HAP or TAP

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr lb/hr ton/yr

    Table 2-I: Stack Exit and Fugitive Emission Rates for HAPs and TAPsIn the table below, report the Potential to Emit for each HAP from each regulated emission unit listed in Table 2-A, only if the entire facility emits the HAP at a rate greater than or equal to one (1) ton per year For each such emission unit, HAPs shall be reported to the nearest 0.1 tpy. Each facility-wide Individual HAP total and the facility-wide Total HAPs shall be the sum of all HAP sources calculated to the nearest 0.1 ton per year. Per 20.2.72.403.A.1 NMAC, facilities not exempt [see 20.2.72.402.C NMAC] from TAP permitting shall report each TAP that has an uncontrolled emission rate in excess of its pounds per hour screening level specified in 20.2.72.502 NMAC. TAPs shall be reported using one more significant figure than the number of significant figures shown in the pound per hour threshold corresponding to the substance. Use the HAP nomenclature as it appears in Section 112 (b) of the 1990 CAAA and the TAP nomenclature as it listed in 20.2.72.502 NMAC. Include tank-flashing emissions estimates of HAPs in this table. For each HAP or TAP listed, fill all cells in this table with the emission numbers or a "-" symbol. A “-” symbol indicates that emissions of this pollutant are not expected or the pollutant is emitted in a quantity less than the threshold amounts described above.

    Provide Pollutant Name Here

    HAP or TAP

    Formaldehyde HAP or TAP

    H2SO4 HAP or TAP

    Ammonia HAP or TAPStack No. Unit No.(s)

    Total HAPs n-Hexane HAP or TAPBenzene

    HAP or TAPToluene

    HAP or TAPEthylbenzene

    HAP or TAPXylene

    HAP or TAP

    TO1 TO1 0.02 0.08 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.00 -- -- -- --

    TO2 TO2 0.02 0.08 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.00 -- -- -- --

    TO3 TO3 0.02 0.08 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.00 -- -- -- --

    TO4 TO4 0.02 0.08 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.02 0.00 0.00 -- -- -- --

    FUG FUG 0.67 2.94 0.16 0.69 0.11 0.46 0.20 0.90 0.01 0.06 0.15 0.66 0.00 0.00 -- -- -- --

    SSM SSM -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

    ROAD ROAD -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

    TO1 AU1

    TO2 AU2

    TO3 AU3

    TO4 AU4

    ECD1 GBS1

    ECD1 PWTK1

    ECD1 PWTK2

    ECD1 SOTK1

    ECD1 SOTL

    GEN1 GEN1 1.93 0.10 0.02 0.00 -- -- -- -- -- -- -- -- 1.76 0.09 -- -- -- --

    GEN2 GEN2 1.93 0.10 0.02 0.00 -- -- -- -- -- -- -- -- 1.76 0.09 -- -- -- --

    GEN3 GEN3 1.93 0.10 0.02 0.00 -- -- -- -- -- -- -- -- 1.76 0.09 -- -- -- --

    GEN4 GEN4 1.93 0.10 0.02 0.00 -- -- -- -- -- -- -- -- 1.76 0.09 -- -- -- -- Totals: 28.8 16.5 11.1 11.3 5.7 1.5 3.5 1.6 0.0 0.1 0.8 0.9 7.1 0.7 0.0 0.0 0.0 0.0

    Emissions are represented at ECD1.

    Emissions are represented at ECD1.

    Emissions are represented at ECD1.

    Emissions are represented at TO3.

    Emissions are represented at TO4.

    Emissions are represented at ECD1.

    Emissions are represented at ECD1.

    Emissions are represented at TO2.

    Emissions are represented at TO1.

    Form Revision: 5/3/2016 Table 2-A: Page 2 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    SHTR1 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/A

    SHTR2 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR3 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR4 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR5 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR6 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR7 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR8 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR9 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/A

    SHTR10 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ASHTR11 Natural Gas Field Gas 993 59345 519.9 < 0.0001 N/ACHTR1 Natural Gas Field Gas 993 95206 834.0 < 0.0001 N/ACHTR2 Natural Gas Field Gas 993 95206 834.0 < 0.0001 N/ACHTR3 Natural Gas Field Gas 993 95206 834.0 < 0.0001 N/ACHTR4 Natural Gas Field Gas 993 95206 834.0 < 0.0001 N/ARHTR1 Natural Gas Field Gas 993 35498 311.0 < 0.0001 N/ARHTR2 Natural Gas Field Gas 993 35498 311.0 < 0.0001 N/ARHTR3 Natural Gas Field Gas 993 35498 311.0 < 0.0001 N/ARHTR4 Natural Gas Field Gas 993 35498 311.0 < 0.0001 N/A

    FL1 Natural Gas Field Gas 1019 35498 311.0 < 0.0001 N/AFL2 Natural Gas Field Gas 1019 35498 311.0 < 0.0001 N/AFL3 Natural Gas Field Gas 1019 35498 311.0 < 0.0001 N/A

    GEN1 Natural Gas Field Gas 1001 24586 215.4 < 0.0001 N/AGEN2 Natural Gas Field Gas 1001 24586 215.4 < 0.0001 N/AGEN3 Natural Gas Field Gas 1001 24586 215.4 < 0.0001 N/AGEN4 Natural Gas Field Gas 1001 24586 215.4 < 0.0001 N/A

    % Ash

    Table 2-J: FuelSpecify fuel characteristics and usage. Unit and stack numbering must correspond throughout the application package.

    Unit No.Fuel Type (low sulfur Diesel,

    ultra low sulfur diesel, Natural Gas, Coal, …)

    Fuel Source: purchased commercial, pipeline quality natural gas, residue gas, raw/field natural gas, process gas (e.g.

    SRU tail gas) or other

    Specify Units

    Lower Heating Value(Btu/scf) Hourly Usage (scf) Annual Usage (mmscf)

    % Sulfur(by weight)

    Form Revision: 5/3/2016 Table 2-A: Page 1 Printed 4/1/2020 12:35 PM

  • XTO Energy Inc. Cowboy CDP March 2020: Revision 0

    IFR1 40400331 Oil/Condensate Oil/Condensate 6.6 62.20 84.15 8.24 93.16 9.38

    IFR2 40400331 Oil/Condensate Oil/Condensate 6.6 62.20 84.15 8.24 93.16 9.38

    IFR3 40400331 Oil/Condensate Oil/Condensate 6.6 62.20 84.15 8.24 93.16 9.38

    IFR4 40400331 Oil/Condensate Oil/Condensate 6.6 62.20 84.15 8.24 93.16 9.38

    IFR5 40400331 Oil/Condensate Oil/Condensate 6.6 57.26 84.86 8.33 93.80 9.46

    IFR6 40400331 Oil/Condensate Oil/Condensate 6.6 57.26 84.86 8.33 93.80 9.46

    IFR7 40400331 Oil/Condensate Oil/Condensate 6.6 57.26 84.86 8.33 93.80 9.46

    IFR8 40400331 Oil/Condensate Oil/Condensate 6.6 57.26 84.86 8.33 93.80 9.46

    GBS1 31000506 Produced Water Produced Water w/ Trace Oils 8.3 55.60 86.50 0.63 95.80 0.85

    PWTK1 40400315 Produced Water Produced Water w/ Trace Oils 8.3 55.60 81.25 11.74 90.51 13.20

    PWTK2 40400315 Produced Water Produced Water w/ Trace Oils 8.3 55.60 81.25 11.74 90.51 13.20

    SOTK1 40400311 Oil/Condensate Oil/Condensate 6.6 54.81 53.32 6.55 62.62 7.72

    Temperature (°F)

    True Vapor Pressure

    (psia)

    Temperature (°F)

    True Vapo