116
A1 Birtley to Coal House Scheme Number: TR010031 Applicant's Response to ExA's Second Written Questions - Appendix 2.0M - Structure Options Report 10 - Retaining Wall Structures Planning Act 2008 Rule 8(1)(b) Infrastructure Planning (Examination Procedure Rules) 2010 Volume 7 April 2020

A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

  • Upload
    others

  • View
    5

  • Download
    0

Embed Size (px)

Citation preview

Page 1: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House

Scheme Number: TR010031Applicant's Response to ExA's Second WrittenQuestions - Appendix 2.0M - Structure OptionsReport 10 - Retaining Wall Structures

Planning Act 2008

Rule 8(1)(b)

Infrastructure Planning (Examination Procedure Rules) 2010

Volume 7

April 2020

Page 2: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House

Infrastructure Planning

Planning Act 2008

The Infrastructure Planning(Examination Procedure Rules)

2010

A1 Birtley to Coal HouseDevelopment Consent Order 20[xx]

Applicant's Response to ExA's Second WrittenQuestions - Appendix 2.0M - Structure Options

Report 10 - Retaining Wall Structures

Rule number: Rule 8(1)(b) Planning Inspectorate SchemeReference

TR010031

Application Document Reference N/A

Author: A1 Birtley to Coal House Project Team,Highways England

Version Date Status of VersionRev 0 20 April 2020 Application Issue

Page 3: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House

Scheme Number: TR010031Applicant's Response to ExA's Second WrittenQuestions - Appendix 2.0M - Structure OptionsReport 10 - Retaining Wall Structures

Planning Act 2008

Rule 8(1)(b)

Infrastructure Planning (Examination Procedure Rules) 2010

Volume 7

April 2020

Page 4: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House

Infrastructure Planning

Planning Act 2008

The Infrastructure Planning(Examination Procedure Rules)

2010

A1 Birtley to Coal HouseDevelopment Consent Order 20[xx]

Applicant's Response to ExA's Second WrittenQuestions - Appendix 2.0M - Structure Options

Report 10 - Retaining Wall Structures

Rule number: Rule 8(1)(b) Planning Inspectorate SchemeReference

TR010031

Application Document Reference N/A

Author: A1 Birtley to Coal House Project Team,Highways England

Version Date Status of VersionRev 0 20 April 2020 Application Issue

Page 5: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Registered office Bridge House, 1 Walnut Tree Close, Guildford, GU1 4LZ Highways England Company Limited registered in England and Wales number 09346363

A1

Birtley to Coal House Improvement Scheme

Structure Option Report 10

Retaining Wall Structures

April 2018

Page 6: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

ii

Project No: HE PIN 551462 WSP Ref: 70015226

Prepared for: Highways England Lateral 8 City Walk Leeds West Yorkshire LS11 9AT

Three White Rose Office Park Millshaw Park Lane Leeds LS11 0DL Tel: +44 (0) 113 395 6200 Fax: +44 (0) 113 395 6201 www.wsp.com

A1 BIRTLEY TO COAL HOUSE IMPROVEMENT SCHEME STRUCTURE OPTION REPORT 10 RETAINING WALL STRUCTURES

Highways England

Date: April 2018

Page 7: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

iii

Q U A L I T Y M A N A G E M E N T ISSUE/REVISION SUITABILITY

FIRST ISSUE P01

REVISION 1 P02

REVISION 2

REVISION 3

Remarks Issue for comments Final Issue – Incorporating HE comments

Date Feb 2018 April 2018

Prepared by Michail Tziolas Michail Tziolas

Signature MTz MTz

Checked by Hitan Mistry Hitan Mistry

Signature HM HM

Authorised by Nigel Rawcliffe Nigel Rawcliffe

Signature NR NR

Project number PIN: 551462

WSP ref: 70015226

Report number HE554162-WSP-SRW-BCH-RP-S-0001

File reference HE554162-WSP-SRW-BCH-RP-S-0001_P02

Page 8: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

iv

P R O D U C T I O N T E A M

CLIENT (HIGHWAYS ENGLAND)

Major Projects Senior Responsible Owner Patrick Moran

Major Projects Programme Manager Patrick Moran

Major Projects Project Manager Nicola Wilkes

RIS Area 14 Coordinator Graeme Watt

Senior User Representative Simon Brown

WSP

RIS Area 14 Programme Director Darren Powell

RIS Area 14 Programme Manager TBA

Project Director Darren Powell

Project Manager Nigel Rawcliffe

Page 9: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

v

TABLE OF CONTENTS EXECUTIVE SUMMARY .............................................................................7

1. INTRODUCTION ...........................................................................9

2. NEW RETAINING WALL LOCATIONS AND DESIGN CONSTRAINTS .......................................................................... 12

3. RETAINING WALL OPTIONS .................................................... 18

4. GEOTECHNICAL INFORMATION ............................................. 28

5. COMPARISON OF RETAINING WALL OPTIONS .................... 34

6. CONCLUSION & RECOMMENDATIONS .................................. 39

Page 10: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

vi

A P P E N D I C E S A P P E N D I X A INDICATIVE SCHEMATIC PLANS OF THE PREFERRED

ROUTE

APPENDIX A-1 INDICATIVE SCHEMATIC PLANS OF THE PREFERRED ROUTE

A P P E N D I X B PLANS & CROSS SECTIONS OF THE PROPOSED NEW RETAINING WALLS

APPENDIX B-1 PLANS OF THE NEW RETAINING WALLS

APPENDIX B-2 CROSS SECTIONS AT THE NEW RETAINING WALL LOCATIONS

A P P E N D I X C STATUTORY UNDERTAKES INFORMATION

APPENDIX C-1 STATUTORY UNDERTAKERS DRAWINGS

APPENDIX C-2 TABULATED OVERVIEW SERVICES IMPACTING THE NEW RETAINING WALLS

A P P E N D I X D RETAINING WALLS PROPOSED GENERAL ARRANGEMENT DRAWINGS

APPENDIX D-1 RETAINING WALL 1 (RW1) GENERAL ARRANGEMENT

APPENDIX D-2 RETAINING WALL 2 (RW2) GENERAL ARRANGEMENT

APPENDIX D-3 RETAINING WALL 3 (RW3) GENERAL ARRANGEMENT

APPENDIX D-4 RETAINING WALL 4 (RW4) GENERAL ARRANGEMENT

APPENDIX D-5 RETAINING WALL 5 (RW5) GENERAL ARRANGEMENT

APPENDIX D-6 RETAINING WALL 6 (RW6) GENERAL ARRANGEMENT

A P P E N D I X E DESIGN RISK ASSESSMENTS

APPENDIX E-1 RW1 DESIGNERS RISK ASSESSMENT

APPENDIX E-2 RW2 DESIGNERS RISK ASSESSMENT

APPENDIX E-3 RW3 DESIGNERS RISK ASSESSMENT

APPENDIX E-4 RW 4 DESIGNERS RISK ASSESSMENT

APPENDIX E-5 RW5 DESIGNERS RISK ASSESSMENT

APPENDIX E-6 RW6 DESIGNERS RISK ASSESSMENT

A P P E N D I X F KEY CORRESPONDENCE WITH HIGHWAYS ENGLAND

APPENDIX F-1 KEY CORRESPONDENCE WITH HIGHWAYS ENGLAND

Page 11: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

7

EXECUTIVE SUMMARY WSP have been commissioned under the CDF contract to progress the Stage 3 Preliminary Design works to increase the capacity of the route between A1 Junction 65 (Birtley) and Junction 67 (Coal House). The scheme involves upgrading the existing Dual 2-Lane All-Purpose provision to a Dual 3-Lane All-Purpose Provision for this section of the road.

To accommodate the improvements to the A1 highway alignment, 10No. new retaining wall structures shall be required. 6No. retaining walls (referenced RW 1-6) are required along the mainline, and 4No. retaining walls are required within the central reserve (reference CRW1-4) to accommodate the level difference between the northbound and southbound carriageway.

This Structures Options Report has been prepared to assess the constraints/challenges associated with the construction of the new earth retaining structures.

The following assumptions/constraints, have been considered when assessing the retaining wall options.

Provision of cost effective/simple solutions

Minimise land take to ensure this is as low as reasonably practical

Minimise disruption to traffic on the mainline and ensure a minimum of 2No. running lanes in both directions can be maintained during the works

Ensure disruption to local residents and business is as low as reasonably practical

All services potentially impacting the works shall be protected or diverted accordingly

VRS shall be provided at the top of retaining walls to prevent errant vehicles from falling

Retaining walls directly adjacent to a traffic face shall be provided with a smooth face (clad or otherwise) in accordance with the requirements of TD19/06 irrespective of a safety barrier provision

Where practical retaining walls less than 1.5m retaining height shall be considered to be contractor designed elements

The gradient to embankment is currently based on the provision of 1:3 slopes. At this stage 1:3 slopes are acceptable where class 2 cohesive material is to be placed, but can increase the gradient of the slope to 1 in 2.5 where a granular material is imported and placed. Slopes of 1:3 have been used to reduce the retained height where possible. The maximum permitted gradient of embankment slopes shall be reviewed upon further detailed geotechnical investigation and analysis

Various retaining wall options (Sheet Piled/Contiguous Bored Piled/RC Cantilever/King Post Wall/RE Wall) have been assessed and compared to provide retention of ground along the mainline.

The limited retained height within the central reserve (min 0.3m/Max 1.0m), due to the level differences between the northbound and southbound carriageway, limits the options to either Option 1 – Wide Variable Concrete Step Barrier or Option 2 RC Ground Beam.

Page 12: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

8

Based on the study to date, it is recommended the following retaining wall options be reviewed and developed further during the detailed design phase of the scheme.

REFERENCE CHAINAGE ON MAINLINE LOCATION

APPROX LENGTH

(M)

MIN RETAINED

HT (M)

MAX RETAINED

HT(M)

AVERGAGE RETAINED

HT (M) OPTIMUM SOLUTION

RW 1 0+340 TO 0+560

MAINLINE/ A1 SOUTHBOUND 220 1.50 2.50 2.00 RC WALL/COST £550K

RW2 0+325 TO 0+420

MAINLINE/ A1 NORTHBOUND 100 0.30 1.70 1.00 SHEET PILED WALL/COST

£300K

RW3 0+650 TO 0+796

MAINLINE/ A1 NORTHBOUND ADJACENT TO THE ON SLIP J67

146 1.50 6.00 3.25 REINFORCED EARTH WALL/COST £750K

RW4 0+940 TO 1+060

MAINLINE/ A1 NORTHBOUND ADJACENT TO THE OFF SLIP J67

125 1.50 4.30 2.80 REINFORCED EARTH WALL/COST £350K

RW5 0+940 TO 1+060

MAINLINE/ A1 SOUTHBOUND ADJACENT TO THE ONSLIP J67

120 1.50 3.00 2.25 CONTIGUOUS BORED PILES/COST £450K

RW6 4+140 TO 4+400

MAINLINE/ A1 SOUTHBOUND ADJACENT TO THE OFFSLIP J65

260 1.50 2.50 2.00 KINGPOST WALL/ COST £500K

CRW1 0+515 TO 0+615

CENTRAL RESERVE 100 0.30 0.36 - TBC-SEE BELOW*

CRW2 1+950 TO 2+220

CENTRAL RESERVE 270 0.30 1.00 - TBC-SEE BELOW*

CRW3 2+420 TO 2+705

CENTRAL RESERVE 285 0.30 0.50 - TBC-SEE BELOW*

CRW4 3+270 TO 3+690

CENTRAL RESERVE 420 0.30 0.80 - TBC-SEE BELOW*

* Due to the limited retained height and simplicity of the options, it is considered that either option will be classified as a CAT0 structure in accordance with BD2/12 Technical Approval of Highway Structures (no AIP required) and will be classified as low risk construction work that can be readily accommodated as part of the scheme improvement works. Further review, taking into considering the carriageway/VRS design and construction interface to determine the preferred option (1 or 2) to sustain the level difference in the central reserve.

The following should be undertaken to verify the finding of this report and clarify works to be developed at detailed design stage;

Further site investigation to determine the location of services and the impact they may have on the retaining wall works.

Review of the carriageway/VRS design and construction to confirm the retaining solution best suited within the central reserve. Although it is noted due to the retained height this work is not anticipated to be onerous.

Page 13: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

9

1. INTRODUCTION 1.1 PROJECT BACKGROUND

1.1.1 WSP have been commissioned by Highways England to develop the preliminary design for the A1 Birtley to Coal House scheme.

1.1.2 The scheme forms part of the Newcastle Gateshead Western Bypass (NGWB) which is located on the A1 between J65 (Birtley) and J80 (Seaton Burn). It is a part of the Highways England’s strategic road network serving the metropolitan area of Tyne and Wear.

1.1.3 This project is located between J65 (Birtley) and J67 (Coal House) on the NGWB and is approximately 4.2km in length. The existing carriageways comprise:

Southbound: Two lanes between Coal House and Eighton Lodge with an additional climbing lane between Smithy Lane and Eighton Lodge and three lanes between Eighton Lodge and Birtley; and

Northbound: Two lanes with a lane gain/lane drop between Birtley and Eighton Lodge and two lanes between Eighton Lodge and Coal House.

1.1.4 The A1 NGWB is one of the most congested highway links in the North-East Region with more than 110,000 vehicles using the route every day on the busiest section. As a result of this travel demand on the route there are a number of issues relating to: journey time delays; journey time reliability; route resilience; safety; environmental impacts and development pressures.

1.1.5 Improvements to the A1 NGWB have long been acknowledged as a requirement for economic growth in the region within both local and national policy documents and reflected in the consensus of opinion amongst regional stakeholders that something needs to be done to address the issues to facilitate the economic growth of the region. The route has been identified as a ‘hot-spot’ requiring Government investment to deliver infrastructure improvements.

1.1.6 Traffic in the region is forecast to grow in the future, largely due to a number of proposed development sites to be delivered through the Newcastle Approved Plan. This additional traffic demand will further exacerbate the issues on the A1 NGWB with traffic modelling work indicating the likely extent of the impacts.

1.1.7 In an attempt to fully understand and address the issues a number of studies have been undertaken in recent years and these include:

TAMMS Multi Modal Study (2002);

Access to Tyne and Wear DaSTS study (2010);

North East DaSTS Strategic Connectivity Study Report (2010);

Newcastle City Deal (2012);

HA Pilot Based Strategy Report (2013);

A1 Newcastle and Gateshead Western Bypass – Exploration of Dual 3-Lane Provisions Initial Infrastructure Report (2013);

Page 14: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

10

DRAFT Route-based strategy: Evidence Report London to Scotland East (February 2014);

The Gateshead and Newcastle Council Core Strategy & Urban Core AAP Draft Infrastructure Delivery Plan has also been used, as well as the Appraisal Specification Report (ASR) for this feasibility study; and

A1 Newcastle/Gateshead Western Bypass Feasibility Study (2014).

1.1.8 The Feasibility Study undertaken in 2014 followed Steps 1 to 10 of the Transport Appraisal Process (TAP) from the Transport Appraisal Guidance (TAG). Stage 1 of the Feasibility Study (Steps 1 to 4 of the TAP) included a comprehensive review of all of the previous studies outlined above to determine the existing issues on the route and prioritise the sections which most urgently needed attention.

1.1.9 Following the prioritisation of sections, Stage 2 (Steps 5 to 9 of the TAP) looked at developing interventions to address the issues highlighted in Stage 1. Interventions were processed through the Early Appraisal Sifting Tool (EAST) and the best performing interventions were put forward through the Options Appraisal Process and scheme cost estimates were produced by the Highways England Commercial Team.

1.1.10 At Stage 3 of the process (Step 10), a Strategic Outline Business Case (SOBC) was produced for the options which performed well at the Options Assessment Stage.

1.1.11 Stages 1 & 2 of the Feasibility Study identified the following sections of the route which should be given priority:

J65 – J67 A1 Birtley to Coal House (including Allerdene Railway Bridge);

J71 – J73 A1 Metrocentre to Derwenthaugh; and

J74 – J79 A1 Scotswood to North Brunton.

At Stage 3, SOBC’s were produced for the following schemes:

J65 – J67 A1 Birtley to Coal House (including Allerdene Railway Bridge); and

J74 – J79 A1 Scotswood to North Brunton.

1.1.12 Both schemes were announced in the Autumn Statement in December 2014 as schemes that should be taken forward into the Roads Investment Strategy (RIS).

1.1.13 The completion of the Feasibility Study concluded PCF Stage 0 (Strategy, Shaping and Prioritisation) for both schemes.

1.1.14 The A1 Birtley to Coal House scheme concluded PCF Stage 1 (Option Identification) in April 2016 and two options were considered at PCF Stage 2 (Option Selection). PCF Stage 2 (Option Selection) concluded in the July 2017 that “Option 1a with the offline replacement of Allerdene Bridge should be the recommended route” [2].

Page 15: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

11

1.2 PREFERRED ROUTE

1.2.1 Between J65 (Birtley) and J66 (Eighton Lodge), the carriageway is to be widened mostly symmetrically on each side of the carriageway by 1 lane, resulting in 3 lanes plus lane gain/drop.

1.2.2 The existing speed limits of 50mph southbound from J67 (Coal House) to Smithy Lane overbridge, 70mph southbound from Smithy Lane to J65 (Birtley) and 50mph throughout the northbound carriageway will be retained. Demolition and reconstruction of North Dene footbridge will be required to accommodate the widening. At J66 (Eighton Lodge) there are 3 underbridges that will also require widening.

1.2.3 Allerdene Bridge will be replaced approximately 40m south of its current location, continuing to use the existing structure to maintain two lanes of traffic while the new bridge is constructed. Kingsway Viaduct will also be widened but no changes will be made to the Lamesley Roundabout at J67 (Coal House).

1.3 PRELIMINARY DESIGN

1.3.1 Following the development of the PCF Stage 2 (Option Selection) traffic model there was a requirement to amend the design to include 4 lanes southbound through J66 (Eighton Lodge). This design change is documented in detail in technical note BTN05: TD 22/06 Mainline Lane Configuration - Final Assessment (dated 8th May 2017) [3]. The current design requires asymmetrical widening whereby the southbound carriageway, is now;

North of J67 (Coal House) – 3 lanes;

Through J67 (Coal House) – 3 lanes;

Between J67 (Coal House) and J66 (Eighton Lodge) – 4 Lanes;

Between J66 (Eighton Lodge) and J65 (Birtley) – 4 lanes; and

South of J65 (Birtley) – 3 lanes.

1.3.2 The scheme is planned to go to public consultation in February 2018, subsequently the design shall be updated further to accommodate feedback. This design will go through the process of obtaining a Development Consent Order (DCO) with a planned start of work in late 2020.

1.4 REPORT OBJECTIVES

1.4.1 This Structures Options Report has been prepared to assess the constraints/challenges associated with the construction of the new earth retaining structures.

1.4.2 The report shall provide a recommendation for the retaining structure considered to be most feasible at each discrete location.

1.4.3 Upon confirmation and sign off, this report shall provide Highways England with sufficient information/justification for seeking approval/funding to progress the scheme within the next stage of development.

Page 16: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

12

2. NEW RETAINING WALL LOCATIONS AND DESIGN CONSTRAINTS

2.1 HIGHWAY ALIGNMENT

2.1.1 Proposed improvements to the highway alignments shall comprise widening of the existing carriageway between J65 (Birtley) and J67 (Coal House) with a lane gain/lane drop between the junctions on both northbound and southbound carriageways.

2.1.2 In the vicinity of the Allerdene bridge works, the A1 is to be re-aligned to the south (Allerdene Bridge proposed new location) where the traffic is carried over the East Coast Mainline between J66 (Eighton Lodge) and J67 (Coal House) with the retention of both junctions.

2.1.3 The widening is generally proposed to be to the north of the existing A1 (from junction 65 to 66), with the retention of the existing edge of the northbound carriageway.

Figure 1 - Proposed Lane Configuration

2.1.4 The southbound carriageway will be 50mph with an urban all-purpose cross section from J67 (Coal House) to Smithy Lane approximately, and beyond this to J65 (Birtley), the speed limit will be 70mph with a rural all-purpose cross section. The northbound carriageway will be 50mph to dual 3-lane urban all-purpose cross-section throughout the length of the scheme.

Page 17: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

13

Figure 2. Proposed Speed Limits

2.1.5 To accommodate the aforementioned improvements to the A1 highway alignment and also minimise additional land take to as low as reasonably practical, 10No. new retaining wall structures shall be required.

2.1.6 Refer to Appendix B for plans providing the following information:

Discrete location of each retaining wall

Approximate length of each retaining wall

Approximate max/min retained heights of each discrete retaining wall

2.1.7 In summary 6No. retaining wall structures (referenced RW 1-6) are required along the mainline, and 4No. retaining walls are required within the central reserve (reference CRW1-4) to accommodate the level difference between the northbound and southbound carriageway.

2.1.8 The following are some of the key constraints and assumptions made in assessing the retaining wall options at each discrete location.

Page 18: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

14

2.2 CONTRACTOR DESIGNED WALLS <1.5M

2.2.1 As discussed/agreed with the HE SES, the extent of the discrete mainline retaining wall lengths have been determined such that where practical, retaining walls with an effective retained height of less than 1.5m shall be considered to be contractor designed elements.

2.2.2 This is considered acceptable on the basis that BD2/12 only recognises retaining structures greater than 1.5m retained height as official highway structures. In this instance it shall be the contractors responsibility to propose a suitable construction method that can be readily transitioned/tied into the main retaining wall structures discussed in this SOR.

2.2.3 Refer to the location plans in appendix B for the extent of consultant and contractor designed wall extent at each discrete location.

2.3 STATUTORY UNDERTAKERS INFORMATION

2.3.1 Details of existing services within the scheme boundary are shown on the following service information plans provided in Appendix C-1:

HE551462-WSP-VUT-BCH-DR-D-00001

HE551462-WSP-VUT-BCH-DR-D-00002

HE551462-WSP-VUT-BCH-DR-D-00003

2.3.2 Refer to Appendix C-2 for details of the services potentially impacted by the proposed new retaining walls.

2.3.3 Further investigation/surveys are required to confirm the line and level of existing services and the level of disruption caused in relation to cost/programme.

2.3.4 At this stage it is assumed all services potentially impacting the retaining wall works will be suitably protected/diverted to accommodate the works on site.

Page 19: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

15

2.4 VRS AND PEDESTRIAN PARAPET ARRANGEMENT

WALLS PROPOSED TO RETAIN THE HIGHWAY

2.4.1 At this stage it has been assumed that all retaining wall structures that could result in errant vehicles falling from height shall be safe guarded with a minimum N2 containment level vehicle restraint system in accordance with TD19/06. Retaining walls with a VRS would need to be designed to sustain impact/accidental loads transmitted from the attached VRS.

2.4.2 Alternatively safety barriers positioned in the verge could remove the requirement for a VRS needing to be fixed along the top of the wall. This would result in retaining structures no longer requiring design for the onerous vehicle impact loading, allowing for a more cost effective retaining structure being provided due to the reduced section size/embedment depth etc.

WALLS PROPOSED TO RETAIN LAND ADJACENT TO THE HIGHWAY

2.4.3 As agreed with the HE SES, all new retaining structures retaining land adjacent to the highway shall be provided with a smooth face up to 1.5m high in accordance with the definition provided in TD19/06 irrespective of a safety barrier provision.

“A ‘smooth’ face may include a surface that may have an irregular surface finish subject to the maximum amplitude of the steps and undulations in the surface not exceeding 30 mm when measured with respect to a plane through the peaks. The plane must be broadly parallel to the road alignment. A structure that has a 25 mm wide chamfered construction joint in its surface would be regarded as smooth.”

2.4.4 In addition all walls adjacent to the highway will be designed for the accidental actions caused by road vehicles and provide the accidental impact loading on supporting structures.

Page 20: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

16

2.4.5 The assumed VRS requirements at each discrete retaining wall location is tabulated below:

Table 1. VRS requirement for retaining walls

REFERENCE CHAINAGE ON MAINLINE LOCATION VRS REQUIREMENTS

RETAINING WALL 1 0+340 TO 0+560 MAINLINE/

A1 SOUTHBOUND

Wall retains the highway

N2 parapet system required (to be confirmed at later design stage).

RETAINING WALL 2 0+325 TO 0+420 MAINLINE/

A1 NORTHBOUND

Wall retains the highway

N2 parapet system required (to be confirmed at later design stage).

RETAINING WALL 3

0+650 TO 0+796 SLIP ROAD/ A1 NORTHBOUND

Wall retains the main highway and also faces the traffic face of the slip road

N2 parapet system required to the top of the wall (to be confirmed at later design stage).

Smooth traffic face required (min 1.5m high) to the traffic face irrespective if safeguarded by a safety barrier provision

RETAINING WALL 4 0+940 TO 1+060 MAINLINE/

A1 NORTHBOUND

Wall retains the main highway and also faces the traffic face of the slip road

N2 parapet system required to the top of the wall (to be confirmed at later design stage).

Smooth traffic face required (min 1.5m high) to the traffic face irrespective if safeguarded by a safety barrier provision (to be confirmed at detailed design)

RETAINING WALL 5 0+940 TO 1+060 MAINLINE/

A1 SOUTHBOUND

Wall retains the main highway and also faces the traffic face of the slip road

N2 parapet system required to the top of the wall (to be confirmed at later design stage).

Smooth traffic face required (min 1.5m high) to the traffic face irrespective if safeguarded by a safety barrier provision (to be confirmed at detailed design)

RETAINING WALL 6 4+140 TO 4+400 MAINLINE/

A1 SOUTHBOUND

Wall retains land adjacent to the highway

N1 parapet system as a stand-alone item required at the top of the wall adjacent to a private access road (to be confirmed at later design stage).

Smooth traffic face required (min 1.5m high) to the traffic face irrespective if safeguarded by a safety barrier provision (to be confirmed at detailed design)

Page 21: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

17

REFERENCE CHAINAGE ON MAINLINE LOCATION VRS REQUIREMENTS

CR RETAINING WALL 1 0+515 TO 0+615 CENTRAL RESERVE

It is anticipated that there will not be a requirement for vehicular restraint system at the top of the retaining wall.

CR RETAINING WALL 2 1+950 TO 2+220 CENTRAL RESERVE

It is anticipated that there will not be a requirement for vehicular restraint system at the top of the retaining wall.

CR RETAINING WALL 3 2+420 TO 2+705 CENTRAL RESERVE

It is anticipated that there will not be a requirement for vehicular restraint system at the top of the retaining wall.

CR RETAINING WALL 4 3+270 TO 3+690 CENTRAL RESERVE

It is anticipated that there will not be a requirement for vehicular restraint system at the top of the retaining wall.

Page 22: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

18

3. RETAINING WALL OPTIONS 3.1 ASSUMPTIONS/CONSTRAINTS

3.1.1 The following assumptions/constraints have been considered when assessing the retaining wall options.

Provision of cost effective/simple solutions

Minimise land take to ensure this is as low as reasonably practical

Minimise disruption to traffic on the mainline and ensure a minimum of 2No. running lanes in both directions can be maintained during the works

Ensure disruption to local residents and business is as low as reasonably practical

All services potentially impacting the works shall be protected or diverted accordingly

VRS shall be provided at the top of retaining walls to prevent errant vehicles from falling

Retaining walls directly adjacent to a traffic face shall be provided with a smooth face (clad or otherwise) in accordance with the requirements of TD19/06 irrespective of a safety barrier provision

Where practical retaining walls less than 1.5m retaining height shall be considered to be contractor designed elements

The gradient to embankment is currently based on the provision of 1:3 slopes. At this stage 1:3 slopes are acceptable where class 2 cohesive material is to be placed, but can increase the gradient of the slope to 1 in 2.5 where a granular material is imported and placed. Slopes of 1:3 have been used to reduce the retained height where possible. The maximum permitted gradient of embankment slopes shall be reviewed upon further detailed geotechnical investigation and analysis

3.1.2 The following options have been considered to provide retention of ground:

Mainline

Option A – Sheet Pile Wall

Option B – Bored Pile Wall

Option C – RC Retaining Wall

Option D – King Post Wall

Option E – Reinforced Earth Wall

3.1.3 Central Reserve

Option 1 – Wide Variable Concrete Step Barrier

Option 2 – RC Ground Beam

Page 23: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

19

3.1.4 Gravity type retaining structures such as gabion and mass concrete walls, which rely on their mass to resist pressure from the load behind, were not considered to be feasible at any of the mainline locations. The reasons for these wall types being discounted is they generally require a considerable foundation footprint and large open excavation for construction. This extent of the open excavation would potentially encroach onto the A1 mainline and impact traffic management, making it difficult to maintain the minimum levels of traffic during construction.

3.1.5 Another reason for gabions not being suitable is they are not compatible with the provision of a VRS system being fixed to the top surface (prevent falls from height). Gabions would also not satisfy the requirement to provide a smooth traffic face.

3.2 OPTION A – SHEET PILE WALL

3.2.1 The sheet piled walls would utilise Z-sections, with the retained and embedded height changing along the length of the wall to suit the retained height.

3.2.2 Steel sheet piles would need to be weathering, include a sacrificial thickness, or be otherwise protected over their design life from rusting caused by the presence of groundwater.

3.2.3 A reinforced concrete capping beam would be provided to the head of the sheet piles. A proprietary VRS system will be required at the top of the capping beam in some locations. In other locations, a proprietary tubular handrail system would be installed.

3.2.4 According to TD19/06 a smooth surface would be required for sections that are adjacent to the traffic and this would extend for at least 1.5m above the adjacent carriageway level.

3.2.5 A drainage or weep hole system would need to be provided in the sheet pile wall to prevent build-up of water behind the wall and avoid adverse uplift on the carriageway. During the detailed design of the retaining walls appropriate drained parameters based on the intrusive ground investigation results will be considered. Drainage is required to prevent pore water pressure build up behind the retaining wall.

3.2.6 Table 2 discusses further the advantages and disadvantages of Option A-Sheet Pile Walls.

Page 24: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

20

Table 2. Sheet Piles Advantages and Disadvantages Table

TECHNIQUE ADVANTAGES DISADVANTAGES SUITABILITY TO SCHEME / COMMENTS

OPTION A (SHEET PILE WALL)

Takes up little lateral space, no additional excavation required.

Deep excavation will not be required to construct the retaining wall. Piles can be installed from existing ground level and then excavation or backfilling carried out as necessary to achieve desired ground levels on each side of the wall. Slope grading can be carried out immediately after installation.

Less spoil and backfill material than the other options, requiring fewer delivery vehicles to dispose of soil off-site.

No temporary works are required to support the existing ground.

Easier and faster installation compared to the other options. Fast installation reducing the period of disruption to residents around the site.

No open excavations and fewer temporary slopes (less risk to health and safety).

Materials handled by machines, reduces manual handling.

Suitable for larger heights to be retained.

Increase in capital cost due to the requirement for specialist equipment.

Difficult to provide an efficient design to sustain retained heights in excess of 3m retained height.

Cannot penetrate hard stratum / obstructions.

Durability of steel sheet piles is not as good as RC options considering design life of 120 years.

May generate significant vibration and noise in close proximity to adjacent residential area.

Requirement for cladding, increasing capital and maintenance cost.

Requirement for piling platform. Risks associated with temporary works installation/ use.

Suitable for use in areas of the scheme where there is little space between the line of the retaining wall and the carriageway or site boundary.

Cost effective solution for retaining walls up to 3m retained height.

Page 25: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

21

3.3 OPTION B –BORED PILED WALL

3.3.1 The length of the retaining structure would be divided into sections with larger pile diameters and greater embedment used for piles retaining a greater height of embankment. Smaller pile diameters and less embedment would be used for smaller retained heights to provide a more cost effective solution.

3.3.2 Similar to option A, bored piles would be installed from ground level using the “top down” method of construction thereby significantly reducing the extent of open excavations whilst allowing for installation within a constrained working area.

3.3.3 The use of a contiguous bored pile walls is considered to be the most appropriate form of construction for large retained heights in excess of 3m, particularly where piles are required to penetrate through hard stratum (limitation of sheet piles). The main disadvantage of this option is that the piles are spaced at approximately 150mm apart therefore a structural concrete facing will be required to prevent soil being washed through the gaps onto the adjacent carriageway/land.

3.3.4 Secant bored pile wall construction comprising hard pile (reinforced) and soft pile (non-reinforced) piles where the soft piles are used to seal the gap between the hard piles to provide a watertight solution, would enable a cheaper form of facing to be adopted. However contiguous bored piles are preferred over secant bored piles on this scheme due to the following:

As the spacing between the hard piles is increased. Secant piles would require a larger diameter of hard piles and a greater quantity of reinforcement than an equivalent contiguous bored piled wall option.

The programme/complexity for installation is greater due to the need to install both soft and hard piles resulting in greater number of piles and movement of installation plant.

Whilst the facing could be more cost effective with a secant pile, a facing of sorts is still required. It is assumed the exposed bored pile face would not be left exposed due to reduced aesthetic appearance and reputational damage to Highways England. Therefore the overall benefits of a secant wall is negated.

3.3.5 A reinforced concrete capping beam would be provided to the head of the contiguous bored piles upon which a VRS/handrail system can be readily attached.

3.3.6 Table 3 discusses further the advantages and disadvantages of Option B-Bored Pile Walls.

Page 26: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

22

Table 3. Bored Pile Advantages and Disadvantages Table

TECHNIQUE ADVANTAGES DISADVANTAGES SUITABILITY TO SCHEME /

COMMENTS

OPTION B (BORED PILE WALL)

Suitable for all heights to be retained.

Takes up little lateral space, no additional excavation required.

Less disruption to the adjacent soil.

Absence of vibration ensures minimal impact on adjacent structures and services.

Deep excavation will not be required to construct the retaining wall. Piles can be installed from existing ground level and then excavation or backfilling carried out as necessary to achieve desired ground levels on each side of the wall. Slope grading can be carried out immediately after installation.

Extensive temporary works are not required to support the existing ground.

Expensive to install given the need for specialist equipment.

Not as cost effective as other retaining wall options for retained heights less than 3m.

Cladding to piles is required. This is due to the presence of small clearance gaps between the piles. The requirement for cladding increases capital and maintenance costs.

The reinforcement is not optimally placed and therefore requires more reinforcement per metre length than a conventional reinforced concrete wall.

Requirement for piling platform. Risks associated with temporary works installation/ use.

Suitable for use in areas of the scheme where there is little space between the line of the retaining wall and the carriageway or site boundary.

Whilst suitable for use on all retained heights. Contiguous bored piled walls are considered to be most cost effective for retained heights in excess of 3m.

Page 27: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

23

3.4 OPTION C – CANTILEVER REINFORCEMENT CONCRETE RETAINING WALL

3.4.1 Cantilever reinforced concrete walls utilise the weight of the backfill soil to provide stability (sliding and overturning). Depending on the retained height, reinforced concrete walls could comprise either cast in-situ (greater than 3m retained height) or pre-cast construction (less than 3m retained height). The height and thickness of the wall could change to suit the retained height providing a more cost effective solution.

3.4.2 To enable the reinforced concrete wall to be constructed, excavation is required past the final plane of retained soil (albeit significantly less than gravity type walls). In the temporary condition, the ground behind the retaining wall will require retaining either by installing temporary sheet piling or by benching of the slope.

3.4.3 Drainage or weep hole system would be required through the wall to prevent build-up of water behind the wall and avoid adverse uplift on the carriageway. During the detailed design of the retaining walls appropriate drained parameters based on the intrusive ground investigation results will be considered. Drainage is required to prevent pore water pressure build up behind the retaining wall.

3.4.4 Table 4 discusses further the advantages and disadvantages of Option C - Cantilever Reinforcement Concrete Retaining Wall.

Table 4. Reinforced Concrete Advantages and Disadvantages Table

TECHNIQUE ADVANTAGES DISADVANTAGES SUITABILITY TO SCHEME

/ COMMENTS

OPTION C (CANTILEVER REINFORCED CONCRETE WALL)

Ease of installation. Precast wall units for smaller retained heights (up to 3m) would significantly reduce complexities associated with insitu construction operations and further expedite the construction programme.

Good surface finish achievable using formwork, requiring no additional cladding.

Reinforcement is optimally placed in the wall faces giving better use of materials.

Reinforcement cages can be constructed to a size applicable for lifting by crane or alternatively fixed manually on site.

Increased construction alignment flexibility as the wall can be constructed with a slight curve to match the A1 alignment if necessary.

For larger heights, the construction of cantilevers retaining walls would result in deep and wide open excavations that would impact TM provisions.

Not suitable where limited access/space constraints exist.

Sensitive to suitable founding strata.

Additional backfill material is required behind retaining walls to construct foundation, also requires more deliveries to site.

Temporary works are required to excavate past the final retained soil surface and then profile or temporarily retain the soil behind.

The overall construction duration is increased particularly for walls retaining in excess of 3m due to the requirement for additional excavation, temporary work installation and extensive in-situ construction work.

Suitable for use where there is sufficient excavation space at the retaining wall locations within impacting land boundaries and traffic management.

Would provide a cost effective simple solution for walls with a retained height less than 3m (based on the option to install precast units).

Page 28: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

24

3.5 OPTION D – KING POST WALL

3.5.1 King post walls are isolated steel columns or beams that are installed along the proposed new retaining wall alignment at typical centres ranging between 1-3m. Between the piles panelling/lagging is inserted to retain the material between each of the piles. The panelling can be made from a variety of materials, normally pre-cast concrete (between 150-180mm thick).

3.5.2 The construction sequence generally comprises the following:

Concrete piles being installed to the toe of the king post pile

Steel H sections are plunged into the concrete to required verticality/alignment and level

Precast concrete panels are installed between the steel sections once the concrete has hardened.

3.5.3 The retained height of the king post retaining wall can be varied along the length of the wall to suit the retained height. A drainage system is required behind the panelling for the king post retaining wall to prevent build-up of water behind the wall and excess seepage through the panels.

3.5.4 King post piles would need to be galvanised, include a sacrificial thickness, or be otherwise protected over their design life from rusting caused by the presence of road salt and water spray from passing vehicles.

3.5.5 This type of wall is considered suitable at locations where lateral loads and the retained height are not significant. In addition the wall would need to be safeguarded by a safety barrier as the panels (limited thickness) would not be able to be designed to sustain vehicle impact loading.

Page 29: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

25

3.5.6 Table 5 discusses further the advantages and disadvantages of Option D – King Post Wall

Table 5. King Post Advantages and Disadvantages Table

TECHNIQUE ADVANTAGES DISADVANTAGES SUITABILITY TO

SCHEME / COMMENTS

OPTION D (KING POST WALL)

At reduced retained heights (circa 2.5m) King post walls provide a cost effective economical solution in comparison to other retaining walls

Can be installed around obstructions and under low headroom.

Can penetrate hard stratum/obstructions.

Usually quick to install.

Choice of type and dimensions of infill panels. Use of precast concrete planks will eliminate any in-situ concrete on site.

Can be installed within a constrained working area.

Structurally inefficient above 2.5m retained height and where subjected to excessive lateral loads (vehicle surcharge loading).

Greater deflection than other wall options

Additional requirement for back of wall drainage prevent seepage through panels.

Larger distance between the king post sections give large panel lengths, reducing flexibility to match the proposed alignment and sloping retained side ground profile.

Durability of king post piles is not as good as RC options considering design life of 120 years.

Only applicable if safeguarded behind a VRS.

Suitable to be used in areas of the scheme where there is little space between the line of the retaining wall and the carriageway or site boundary.

Suitable to use where high bedrock expected (cost effective alternative to bored piled walls) and where the height and lateral loads are limited.

3.6 OPTION E – REINFORCED EARTH WALL

3.6.1 Reinforced earth retaining walls comprise a combination of a compacted fill (often granular and free draining) reinforced with plastic or galvanised metal straps/grids which are attached to a facing system. The chosen facing system is dependent on the face angle required. For vertical/near-vertical walls, the facing systems is generally either a concrete segmental block or interlocking panelling, which can be supplied in a variety of finishes.

3.6.2 No foundation is required below the reinforced earth, although depending on the underlying ground conditions, ground improvement may be required. A concrete levelling pad is required at the base of the facing system to provide a level surface from which to build upon.

3.6.3 The height and alignment of the reinforced earth retaining wall can be varied along the length of the wall to suit the retained height. A drainage system may be required at the base of the reinforced earth block and/or behind the facing system to prevent build-up of water within the wall.

3.6.4 Precast reinforced concrete parapet support slabs can be fixed to the top of the wall to accommodate a VRS appropriate to the adjacent carriageway risks.

Page 30: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

26

3.6.5 Table 6 discusses further the advantages and disadvantages of Option E – Reinforced Earth Wall

Table6. Reinforced Earth Wall Advantages and Disadvantages Table

TECHNIQUE ADVANTAGES DISADVANTAGES SUITABILITY TO

SCHEME / COMMENTS

OPTION E (REINFORCED EARTH WALL)

Structural flexibility.

Requires very little working area in front of wall. Reduce disruption to and from operational A1 main line and slip road.

Cost effective solution due to simplicity of construction and limited requirement for complex plant and equipment.

Rapid and economical form of construction can reduce the overall scheme construction programme.

Typically founded at shallow depth, no pilling required.

Requires no footing beyond the front face of the wall.

Can be constructed entirely from the backfill side of the wall, requiring no equipment or scaffolding in front of the wall.

Variety of possible finishes increases aesthetic appearance.

Excessive working room is required behind the wall to facilitate construction.

Because of shallow foundation depth, the reinforced earth wall location may be subject to settlement issues.

Requires high quality backfill to be correctly compacted and testing of layers is essential to remove any issue with future settlement.

Subject to out of plane movements and settlements if fill not correctly compacted.

Provides a cost effective solution due to the rapid construction techniques that can be deployed.

Suitability is dependent on sufficient working room and adequate control of potential settlement.

Page 31: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

27

3.7 CENTRAL RESERVE RETAINING WALL OPTIONS

3.7.1 The limited retained height within the central reserve due to the level difference between the northbound and southbound carriageway suggest the retaining wall options will be limited to either of the following.

Option 1 – Wide Variable Concrete Step Barrier

Option 2 – RC Ground Beam

3.7.2 Option 1 requires the installation of a proprietary pre-cast variable concrete step barrier that has a dual purpose of providing adequate VRS containment and limited ground retention up to 300mm retained height.

3.7.3 Option 2 is based on the provision of a reinforced concrete ground beam where ground retention is expected to be between 300-1000mm. The ground beam could comprise either cast in-situ or pre-cast construction.

Page 32: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

28

4. GEOTECHNICAL INFORMATION 4.1.1 A Geotechnical Design Report is not yet available for the project and will be prepared, following

completion of the ground investigation that is currently being undertaken on the site. The GDR will define suitable parameters for the design and acceptable retaining solutions,

4.1.2 Within this options report, a selection of appropriate retaining solutions have been considered based on the records and findings for the site location, taken from the Preliminary Sources Study Report (PSSR) for the wider Birtley to Coalhouse Scheme (HA544664-WSP-HGT-S01-RP-GE-0600-P-01).

4.1.3 Below is a summary of the ground conditions in the vicinity of the six mainline retaining walls and the four central reservation retaining walls. The ground conditions are based on the historical ground investigation data from the British Geological Survey (BGS) and Highways Agency Geotechnical Data Management System (HA GDMS). Once the scheme specific ground investigation has been undertaken the ground conditions will be updated accordingly.

4.1.4 Given the proximity of the proposed retaining walls to the existing carriageway and their locations on existing slopes, it is not feasible to conduct a comprehensive ground investigation for each specific retaining wall. As such, some supplementary ground investigation may be required during detailed design, or at the start of construction to confirm assumptions made.

4.1.5 Table 7 below presents the anticipated ground conditions at each of the retaining wall locations.

Table7: Anticipated ground conditions at each proposed retaining wall location

RETAINING WALL GROUND CONDITIONS

RETAINING WALL 1 (RW1)

Made ground: embankment fill from the construction of the A1 carriageway; over,

Alluvium: between 2.9 m and 4.0 m thick and comprising soft to firm brown grey silty locally sandy clay and brown fine to coarse gravel; over,

Glaciolacustrine deposits: thickness not proven, maximum proven thickness 11.7 m and comprising firm grey brown laminated clay locally silty laminated clay; over,

Pennine Middle Coal Measures bedrock, although the depth to this stratum has not been proven in the historical borehole records obtained.

Groundwater strikes were recorded on the available historical borehole records between 14.1 and 6.45 m AOD. No historical groundwater monitoring results have been obtained.

Page 33: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

29

RETAINING WALL GROUND CONDITIONS

RETAINING WALL 2 (RW2)

Made ground: embankment fill from the construction of the A1 carriageway; over,

Alluvium: between 2.9 m and 4.0 m thick and comprising firm brown grey silty clay; over,

Glaciolacustrine deposits: thickness not proven, maximum proven thickness 14.6 m and comprising firm grey brown laminated clay, locally silty laminated clay; over,

Pennine Middle Coal Measures bedrock, although the depth to this stratum has not been proven in the historical borehole records obtained.

Groundwater strikes were recorded on the available historical borehole records between 14.1 and 6.45 m AOD. No historical groundwater monitoring results have been obtained.

RETAINING WALL 3 (RW3)

Made ground: embankment fill from the construction of the A1 carriageway; over,

Alluvium: between 2.9 m and 4.0 m thick and comprising soft to firm brown silty sandy clay, clayey sand and gravel, and dark grey silty sand; over,

Glaciolacustrine deposits: thickness not proven, maximum proven thickness 11.7 m and comprising soft to firm grey brown laminated slightly silty clay; over,

Pennine Middle Coal Measures bedrock, although the depth to this stratum has not been proven in the historical borehole records obtained.

Groundwater strikes were recorded on the available historical borehole records between 9.3 and 6.7 m AOD. No historical groundwater monitoring results have been obtained.

RETAINING WALL 4 AND 5 (RW4&5)

Made ground: embankment fill from the construction of the A1 carriageway; over,

Alluvium: between 0.6 m and 2.0 m thick and comprising soft to stiff grey brown sandy clay; over,

Glaciolacustrine deposits: thickness not proven, maximum proven thickness 36.9 m and comprising soft to stiff grey brown laminated silty clay; over,

Pennine Middle Coal Measures bedrock, although the depth to this stratum has not been proven in the historical borehole records obtained.

Groundwater strikes were recorded on the available historical borehole records between 9.5 and 1.9 m AOD. No historical groundwater monitoring results have been obtained.

Page 34: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

30

RETAINING WALL GROUND CONDITIONS

RETAINING WALL 6 (RW6)

Made ground: embankment fill from the construction of the A1 carriageway; over,

Glacial Till: between 2.8 m and 7.8 m thick and comprising firm to stiff orange brown slightly sandy slightly gravelly clay, gravel is sandstone, siltstone, mudstone and coal; over,

Weathered Pennine Middle Coal Measures: between 0.1 m and 0.3 m and comprising brown medium to coarse sand and gravel of sandstone; over,

Pennine Middle Coal Measures bedrock: thickness not proven, maximum proven thickness 5.1 m.

No groundwater strikes were recorded on the available historical borehole records. No historical groundwater monitoring results have been obtained.

A number of coal seams are recorded beneath the retaining wall, however no evidence of mine workings are recorded on the available borehole logs. The shallowest coal seams are the High Main (approximately 67 m AOD), Metal seam (approximately 60 m AOD) and Five Quarter (approximately 50 m AOD)

CENTRAL RESERVATION RETAINING WALL 1 (CRW1)

Made ground: existing embankment fill; over,

Alluvium: between 2.9 m and 4.0 m thick and comprising firm grey brown clay; over,

Glaciolacustrine deposits: thickness not proven, maximum proven thickness 14.6 m and comprising firm grey brown silty laminated clay; over,

Pennine Middle Coal Measures bedrock, although the depth to this stratum has not been proven in the historical borehole records obtained.

Groundwater strikes were recorded on the available historical borehole records between 14.1 and 6.5 m AOD. No historical groundwater monitoring results have been obtained.

CENTRAL RESERVATION RETAINING WALL 2 (CRW2)

Made ground: up to 2.5 m thick, over,

Glacial Till: between 2.4 m and 5.4 m thick and firm to stiff orange brown slightly sandy slightly gravelly clay, gravel is sandstone, siltstone, mudstone and coal; over,

Weathered Pennine Middle Coal Measures: between 0.8 m and 1.9 m and comprising very stiff grey brown silty clay tending to weak siltstone; over,

Pennine Middle Coal Measures bedrock: thickness not proven, maximum proven thickness 14.0 m.

No groundwater strikes were recorded on the available historical borehole records. No historical groundwater monitoring results have been obtained.

A number of coal seams are recorded beneath the retaining wall, however no evidence of mine workings are recorded on the available borehole logs. The shallowest coal seams are the High Main (approximately 67 m AOD), Metal seam (approximately 60 m AOD) and Five Quarter (approximately 50 m AOD).

Page 35: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

31

RETAINING WALL GROUND CONDITIONS

CENTRAL RESERVATION RETAINING WALL 3 (CRW3)

Made ground: up to 2.7 m thick, over,

Glacial Till: between 1.6 m and 5.6 m thick and comprising firm to stiff brown sandy clay, grey silty clay, dark brown gravelly clay with localised sandstone boulders; over,

Weathered Pennine Middle Coal Measures: approximately 2.0 m thick and comprising brown clayey sand and stiff to very stiff grey brown silty clay; over,

Pennine Middle Coal Measures bedrock: thickness not proven, maximum proven thickness 12.0 m.

No groundwater strikes were recorded on the available historical borehole records. No historical groundwater monitoring results have been obtained.

A number of coal seams are recorded beneath the retaining wall, however no evidence of mine workings are recorded on the available borehole logs. The shallowest coal seams are the High Main (approximately 67 m AOD), Metal seam (approximately 60 m AOD) and Five Quarter (approximately 50 m AOD).

CENTRAL RESERVATION RETAINING WALL 4 (CRW4)

Made ground: approximately 2.0 m thick; over,

Glacial Till: approximately 5.8 m thick and comprising firm to stiff orange brown slightly sandy slightly gravelly clay, gravel is sandstone, siltstone, mudstone and coal; over,

Pennine Middle Coal Measures bedrock: thickness not proven, maximum proven thickness 22.7 m.

No groundwater strikes were recorded on the available historical borehole records. No historical groundwater monitoring results have been obtained.

A number of coal seams are recorded beneath the retaining wall, however no evidence of mine workings are recorded on the available borehole logs. The shallowest coal seams are the High Main (approximately 67 m AOD), Metal seam (approximately 60 m AOD) and Five Quarter (approximately 50 m AOD).

Page 36: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

32

4.2 RISKS ASSOCIATED WITH RETAINING WALL WORKS

4.2.1 The geotechnical risks for the wider site are presented within the PSSR. These risks have been reviewed and further assessed in the ‘Live’ Project Risk Registers. Pertinent geotechnical risks in relation to the proposed retaining walls are summarised in Table below.

Table 8: Geotechnical risks of proposed retaining walls

RISK CAUSE RISK EVENT PRIMARY RISK IMPACT RISK RATING*

ENGINEERING

PROPERTIES OF THE

GROUND

THERE IS A RISK THAT THE GROUND MODEL, AND THE BEHAVIOUR OF SUCH, IS DIFFERENT (WORSE) FROM THAT ASSUMED AT THIS STAGE. CONSTRUCTION DELAYS AND

REMEDIAL DESIGN REQUIREMENTS, AND POTENTIAL COST AND PROGRAMME IMPLICATIONS. MAINTENANCE INCREASED DEFLECTIONS/MOVEMENTS OVER THE LIFESPAN OF THE RETAINING STRUCTURES, INCREASED MAINTENANCE AND POTENTIAL REMEDIAL MEASURE REQUIREMENTS.

MEDIUM

INSTABILITY OF

EXISTING

EARTHWORKS

THERE IS A RISK THAT THE PROPOSED WORKS MAY UNDERMINE/DESTABILISE EXISTING EARTHWORKS.

MEDIUM

INSTABILITY OF

EXISTING

EARTHWORKS

THERE IS A RISK THAT THE EXISTING EARTHWORKS AT THE SITE ARE NOT AS STABLE AS ASSUMED AT THIS STAGE.

MEDIUM

GROUNDWATER

THERE IS A RISK THAT THE GROUNDWATER MODEL IS DIFFERENT (WORSE) FROM THAT ASSUMED AT THIS STAGE.

MEDIUM

CONTAMINATED

SOILS

THERE IS A RISK THAT THE ASSESSMENT OF CONTAMINATED SOILS UNDERTAKEN AT THIS STAGE IS NOT ACCURATE.

MEDIUM

INSTABILITY CAUSED

BY SHALLOW MINE

WORKINGS

THERE IS A RISK THAT THE STRUCTURE WILL BE ADVERSELY IMPACTED BY COLLAPSE OF SHALLOW COAL MINE WORKINGS, WHICH MAY REQUIRE GROUTING DURING CONSTRUCTION.

CONSTRUCTION DELAYS AND REMEDIAL DESIGN REQUIREMENTS, AND POTENTIAL COST AND PROGRAMME IMPLICATIONS.

MEDIUM

CONSTRUCTABILITY

OF CHOSEN

RETAINING WALL

SOLUTIONS

THERE IS A RISK THAT THE PROPOSED RETAINING WALL SOLUTIONS ARE NO LONGER SUITABLE DUE TO THE UNCERTAINTY OF THE GROUND CONDITIONS, SUCH AS ROCKHEAD BEING HIGHER THAN ANTICIPATED, BOULDERS AND OTHER OBSTRUCTIONS BEING PRESENT.

CONSTRUCTION DELAYS AND REMEDIAL DESIGN REQUIREMENTS, AND POTENTIAL COST AND PROGRAMME IMPLICATIONS.

MEDIUM

UNEXPLODED

ORDNANCE (UXO)

THE SITE IS LOCATED WITHIN AN AREA OF LOW BOMB RISK, THERE IS A RISK THAT UXO MIGHT BE ENCOUNTERED BENEATH THE SITE.

CONSTRUCTION DELAYS AND REQUIREMENT FOR SAFE DEACTIVATION / DISPOSAL.

LOW

BURIED SERVICES

THERE IS A RISK THAT BURIED SERVICES MIGHT BE ENCOUNTERED DURING EXCAVATION OF PROPOSED FOUNDATIONS.

CONSTRUCTION DELAYS AND POTENTIAL COST AND PROGRAMME IMPLICATIONS.

MEDIUM

Page 37: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

33

4.3 DETAILS OF ADDITIONAL GROUND INVESTIGATION REQUIRED TO INFORM THE DETAILED DESIGN PROCESS

4.3.1 The additional proposed ground investigation has been scoped and is currently being undertaken. Drawings HE551462-WSP-HGT-BCH-DR-GE-00023 to HE551462-WSP-HGT-BCH-DR-GE-00033 shows the exploratory hole locations of the proposed ground investigation required to inform the detailed design of the retaining wall. The proposed ground investigation includes the following:

Cable percussion boreholes to rock head to identity ground conditions within the superficial deposits and confirm rockhead levels;

Rotary cored boreholes to determine rock quality and strength to 9 m below rock head;

Rotary open hole boreholes for an additional 15 m to investigate the presence of coal seams and historical mining;

Window sample; and,

Installation of piezometer data loggers to monitor the groundwater levels.

4.3.2 Each of the above ground investigation methodologies may be undertaken at the same location / exploratory hole through follow-on methods, i.e. cable percussion to rockhead; follow-on with rotary core from rockhead to 12m below rockhead; and follow-on with open hole to proposed borehole depth. The current proposed ground investigation includes 15 (fifteen) exploratory hole locations.

4.3.3 The ground investigation shall be reported in a Ground Investigation Report (in line with HD 22/08) once completed.

4.3.4 Given the proximity of the proposed retaining walls to the existing carriageway and their locations on existing slopes, it is not feasible to conduct a comprehensive ground investigation for each specific retaining wall. As such, some supplementary ground investigation may be required during detailed design, or at the start of construction to confirm assumptions made.

4.3.5 The final retaining wall solutions shall be determined through assessment of the deflections and bending moments of the walls, bearing capacity of the founding materials (influenced by the ultimate limit state), settlement analysis of the foundations (influenced by serviceability limit state) and interaction with the existing structure.

Page 38: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

34

5. COMPARISON OF RETAINING WALL OPTIONS

5.1 GENERAL

5.1.1 The various mainline retaining wall options (A-E) have been assessed and compared relative to the working constraints identified at each location. The review has also included high level early buildability input from the HE support contractor (COSTAIN). Based on the study to date a preferred retaining wall option at each discrete location has been identified for further consideration/development at detailed design.

5.1.2 All construction costing information (excluding preliminaries) provided in this section is based on previous similar type works and subject to further verification and analysis. The Highways England cost estimating team has not been consulted for any construction costing information in this study.

5.2 MAINLINE RETAINING WALL 1

5.2.1 Key geometric details of this retaining wall include (approximate):

Total length 220m

Min height 1.50m

Max height 2.50m

Average height 2.00m

5.2.2 This wall would retain the construction of the A1 southbound alignment. The buildability review has indicated the three most suitable solutions at this location are:

Option A Sheet Piled Wall (Estimated Construction Cost £650k)

Option C Insitu RC Wall (Estimated Construction Cost £600k)

Option C Precast RC Wall (estimated Construction Cost £550k)

5.2.3 Due to the limited retained height, contiguous bored piled walls (option B) would not provide a cost effective solution at this location. The excavation and access to construct a Reinforced Earth wall would be in excess of the working room available. The king post wall would not be adequate due to the excess lateral loads (due to earth pressure and live load surcharge) to be sustained by the structure.

5.2.4 Option C Precast RC Wall is considered to provide the most cost effective solution. The limited insitu works would simplify buildability and most likely reduce the programmed retaining wall works at this location. Refer to Appendix D-1 for the outline GA.

Page 39: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

35

5.3 MAINLINE RETAINING WALL 2

5.3.1 Key geometric details of this retaining wall include (approximate):

Total length 100m

Min height 0.30m

Max height 1.70m

Average height 1.00m

5.3.2 This wall would retain the construction of the A1 southbound alignment. The limited working room at this location negates all options requiring open excavated areas for construction (Options D: RC Retaining wall and E: Reinforced Earth options). The limited retained height means contiguous bored piled walls (option B) would not provide a cost effective solution at this location.

5.3.3 Based on the above the optimum solution inclines towards a sheet piled wall which can be constructed in a restricted working areas minimising impact on the traffic management during construction.

5.3.4 The estimated construction cost of Option A Sheet Piled Wall is £300k. Refer to Appendix D-2 for the outline GA.

5.4 MAINLINE RETAINING WALL 3

5.4.1 Key geometric details of this retaining wall include (approximate):

Total length 146m

Min height 1.50m

Max height 6.00m

Average height 3.25m

5.4.2 This wall would retain the construction of the A1 northbound alignment and face the adjacent on slip traffic. The buildability review has indicated the two most suitable options at this location are:

Option B Contiguous Bored Piled Wall (Estimated Construction Cost £1.8million)

Option E Reinforced Earth Wall (Estimated Construction Cost £750k)

Page 40: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

36

5.4.3 The excessive retained height at this location makes option A (Sheet Piles), C (Cantilever Retaining Walls) and D (King post) not adequate for installation at this location.

5.4.4 Option B would allow for a retaining wall to be installed that is aligned tight to the verge edge minimising additional land take for construction whilst also maintaining the required traffic management on the mainline.

5.4.5 Option E Reinforced Earth Wall would provide a more cost effective solution, however this option would require greater land take (increase lateral clearance to the running lane) to facilitate access for construction and also allow for the minimum levels of traffic to be maintained during construction.

5.4.6 On the basis the additional land take is within acceptable limits, it is considered Option E Reinforced Earth walls would provide the optimum solution in relation to cost and buildability. Refer to Appendix D-3 for the outline GA.

5.5 MAINLINE RETAINING WALL 4

5.5.1 Key geometric details of this retaining wall include (approximate):

Total length 125m

Min height 1.50m

Max height 4.30m

Average height 2.80m

5.5.2 This wall would retain the construction of the A1 northbound alignment and face the adjacent off slip road traffic. The buildability review has indicated the two most suitable options at this location are:

Option C RC Wall (Estimated Construction Cost £800k)- comprise both insitu and precast construction

Option E Reinforced Earth Wall (Estimated Construction Cost £350k)

5.5.3 Option A Sheet Piled Walls is considered to not be feasible due to the shallow depth of hard stratum that would prevent the driving of sheet piles to the required embedment depth. Also, due to the nature of the sheet pile composition/ material, it will make them unfeasible to support excessive deflection as a result of retaining height. Option B Contiguous bored piles was not considered in detail at this location as it would provide an expensive solution in comparison to the averaged retained height to be maintained.

5.5.4 Option C and E are considered to provide the most suitable retaining wall solution on the basis the increased construction footprint could be accommodated, whilst allowing for the desired traffic management to be maintained on the mainline during construction.

5.5.5 It is considered that Option E Reinforced Earth Wall would provide the optimum cost effective solution at this location. Refer to Appendix D-4 for the outline GA.

Page 41: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

37

5.6 MAINLINE RETAINING WALL 5

5.6.1 Key geometric details of this retaining wall include (approximate):

Total length 120m

Min height 1.50m

Max height 3.00m

Average height 2.25m

5.6.2 This wall would retain the construction of the A1 southbound alignment and face the adjacent on slip road traffic. The buildability review has indicated the most suitable option at this location is:

Option B Contiguous Bored Piled Wall (Estimated Construction Cost £450k)

5.6.3 The buildability review highlighted retaining wall options requiring a large construction footprint (Option C: Cantilever RC Wall and Option E: Reinforced Earth) would not be feasible due to the restricted working area and the need to maintain traffic on the mainline during construction.

5.6.4 Option D was also not considered in detail as the anticipated loading would make it difficult for a king post solution to work structurally and also remain cost effective.

5.6.5 Option A sheet piled wall is not considered feasible as this type of structure could only be installed for a short length, 40m of the total 120m length. This is due to a change in stratum whereby hard material would be encountered for circa 80m which would prevent sheets from being installed to the desired embedment depth. Also, due to the nature of the sheet pile composition/ material, it will make them unfeasible to support the excessive deflection as a result of the retaining height. A combination of sheet and contiguous bored piles is also not considered feasible due to the disruption/complexity associated with the transition from sheet piles to contiguous bored piled walls.

5.6.6 At this stage it is considered the contiguous bored pile wall would provide the most effective buildable solution at this location. Refer to Appendix D-5 for the outline GA.

Page 42: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

38

5.7 MAINLINE RETAINING WALL 6

5.7.1 Key geometric details of this retaining wall include (approximate):

Total length 260m

Min height 1.50m

Max height 2.50m

Average height 2.00m

5.7.2 This wall would retain the earthwork cutting adjacent to the A1 southbound offslip road. The shallow depth hard stratum would make Option A Sheet Piles impractical for installation at this location. The limited retained height would result in a contiguous bored pile wall option providing a solution that would be too expensive (circa £900k).

5.7.3 The limited space in relation to the highway boundary would result in Options C: Cantilever retaining wall and Option E: Reinforced Earth wall requiring additional land take beyond the current highway boundary and are therefore not considered feasible.

5.7.4 Option D: King post wall would provide the optimum cost effective solution at this location whilst allowing for the wall to be constructed without the need for additional land take.

5.7.5 The estimated construction cost of Option D King post wall is £500k. Refer to Appendix D-6 for the outline GA.

5.8 CENTRAL RESERVE RETAINING WALLS

5.8.1 The current geometric requirements for the 4No. discrete central reserve retaining walls identified for the improvement works is provided below:

Central Reserve Retaining wall 1 (CRW1) - Length 100m/ Min & Max Ht 0.3m and 0.36m

Central Reserve Retaining wall 2(CRW2) - Length 270m/ Min & Max Ht 0.3m and 1.00m

Central Reserve Retaining wall 3(CRW3) – Length 285m/ Min & Max Ht 0.3m and 0.50m

Central Reserve Retaining wall 4(CRW4) – Length 420m/ Min & Max Ht0.3m and 0.80m

5.8.2 The central reserve retaining wall Option 1 Variable Step Barrier and Option 2 Ground Beam, are considered to provide the most cost effective/optimum solutions in this location. The choice between the options will be directly governed by the retained height requirements at each location.

5.8.3 Due to the limited retained height and simplicity of the options, it is considered that either option will be classified as a CAT0 structure in accordance with BD2/12 Technical Approval of Highway Structures (no AIP required) and will be classified as low risk construction work that can be readily accommodated as part of the scheme improvement works.

5.8.4 Further review, taking into considering the phasing of the new carriageway construction is required prior to confirming the preferred option to sustain the level difference in the central reserve.

Page 43: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

39

6. CONCLUSION & RECOMMENDATIONS

6.1 CONCLUSION

6.1.1 To accommodate the improvements to the A1 highway alignment, 10No. new retaining wall structures shall be required. 6No. Retaining wall structure (referenced RW 1-6) are required along the mainline, and 4No. Retaining walls are required within the central reserve (reference CRW1-4) to accommodate the level difference between the northbound and southbound carriageway.

6.1.2 The following assumptions/constraints, have been considered when assessing the retaining wall options.

Provision of cost effective/simple solutions

Minimise land take to ensure this is as low as reasonably practical

Minimise disruption to traffic on the mainline and ensure a minimum of 2No. running lanes in both directions can be maintained during the works

Ensure disruption to local residents and business is as low as reasonably practical

All services potentially impacting the works shall be protected or diverted accordingly

VRS shall be provided at the top of retaining walls to prevent errant vehicles from falling

Retaining walls directly adjacent to a traffic face shall be provided with a smooth face (clad or otherwise) in accordance with the requirements of TD19/06 irrespective of a safety barrier provision

Where practical retaining walls less than 1.5m retaining height shall be considered to be contractor designed elements

The gradient to embankment is currently based on the provision of 1:3 slopes. At this stage 1:3 slopes are acceptable where class 2 cohesive material is to be placed, but can increase the gradient of the slope to 1 in 2.5 where a granular material is imported and placed. Slopes of 1:3 have been used to reduce the retained height where possible. The maximum permitted gradient of embankment slopes shall be reviewed upon further detailed geotechnical investigation and analysis

Page 44: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

40

6.1.3 Various retaining wall options (Sheet Piled/Contiguous Bored Piled/RC Cantilever/King Post Wall/RE Wall) have been assessed and compared to provide retention of ground along the mainline.

6.1.4 The limited retained height within the central reserve (min 0.3m/Max 1.0m) due to the level difference between the northbound and southbound carriageway limits the options to either Option 1 – Wide Variable Concrete Step Barrier or Option 2RC Ground Beam

6.1.5 Option 1 requires the installation of a proprietary pre-cast variable concrete step barrier that has a dual purpose of providing adequate VRS containment and limited ground retention up to 300mm retained height. Option 2 is based on the provision of a reinforced concrete ground beam where ground retention is expected to be between 300-1000mm. The ground beam could comprise either cast in-situ or pre-cast construction.

6.2 RECOMMENDATION

6.2.1 Based on the study to date it is recommended the following retaining wall options be reviewed and developed further during the detailed design phase of the scheme.

REFERENCE CHAINAGE ON MAINLINE LOCATION APPROX

LENGTH (M)

MIN RETAINED HT (M)

MAX RETAINED HT(M)

AVERGAGE RETAINED HT (M)

OPTIMUM SOLUTION

RW 1 0+340 TO 0+560

MAINLINE/ A1 SOUTHBOUND 220 1.50 2.50 2.00 RC WALL/COST £550K

RW2 0+325 TO 0+420

MAINLINE/ A1 NORTHBOUND 100 0.30 1.70 1.00 SHEET PILED WALL/COST

£300K

RW3 0+650 TO 0+796

MAINLINE/ A1 NORTHBOUND ADJACENT TO THE ON SLIP J67

146 1.50 6.00 3.25 REINFORCED EARTH WALL/COST £750K

RW4 0+940 TO 1+060

MAINLINE/ A1 NORTHBOUND ADJACENT TO THE OFF SLIP J67

125 1.50 4.30 2.80 REINFORCED EARTH WALL/COST £350K

RW5 0+940 TO 1+060

MAINLINE/ A1 SOUTHBOUND ADJACENT TO THE ONSLIP J67

120 1.50 3.00 2.25 CONTIGUOUS BORED PILES/COST £450K

RW6 4+140 TO 4+400

MAINLINE/ A1 SOUTHBOUND ADJACENT TO THE OFFSLIP J65

260 1.50 2.50 1.70 KINGPOST WALL/ COST £500K

CRW1 0+515 TO 0+615 CENTRAL RESERVE 100 0.30 0.36 - TBC-SEE BELOW*

CRW2 1+950 TO 2+220 CENTRAL RESERVE 270 0.30 1.00 - TBC-SEE BELOW*

CRW3 2+420 TO 2+705 CENTRAL RESERVE 285 0.30 0.50 - TBC-SEE BELOW*

CRW4 3+270 TO 3+690 CENTRAL RESERVE 420 0.30 0.80 - TBC-SEE BELOW*

* Due to the limited retained height and simplicity of the options, it is considered that either option will be classified as a CAT0 structure in accordance with BD2/12 Technical Approval of Highway Structures (no AIP required) and will be classified as low risk construction work that can be readily accommodated as part of the scheme improvement works. Further review, taking into considering the carriageway/VRS design and construction interface to determine the preferred option (1 or 2) to sustain the level difference in the central reserve.

Page 45: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1 Birtley to Coal House Improvement Scheme PCF Stage 3 – Structure Options Report 10: Retaining Wall Structures

41

The following should be undertaken to verify the finding of this report and clarify works to be developed at detailed design stage;

Further site investigation to determine the location of services and the impact they may have on the retaining wall works

Review of the carriageway/VRS design and construction to confirm the retaining solution best suited within the central reserve. Although it is noted due to the retained height this work is not anticipated to be onerous.

Page 46: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Appendix A

INDICATIVE SCHEMATIC PLANS OF THE PREFERRED ROUTE

Page 47: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX A-1

INDICATIVE SCHEMATIC PLANS OF THE PREFERRED ROUTE

Page 48: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
UKGXB603
Text Box
Kingsway Viaduct Underbridge OS Grid Ref: 424900E, 558550N STKEY 16271 Structure No. A1/433.30 AIP - Kingsway Viaduct Ref SOR01
UKGXB603
Text Box
Allerdene Culvert OS Grid Ref: 425370E, 558520N STKEY 8879 Structure No. A1/443.30 AIP - Allerdene Culvert Ref SOR02
UKGXB603
Text Box
Smithy Lane Overbridge OS Grid Ref: 425760E, 558280N STKEY 16439 Structure No. A1/442.50 AIP - Smithy Lane Overbridge Ref SOR04
UKGXB603
Text Box
Allerdene Railway Underbridge OS Grid Ref: 425480E, 558489N STKEY 8880 Structure No. A1/443.00/Q AIP - Allerdene Railway Bridge Ref SOR03
UKGXB603
Callout
Retaining wall 1 AIP - Reinforced Concrete Wall STKEY TBC Ref SOR10
UKGXB603
Callout
Retaining wall 2 AIP - Sheet Piles Retaining Wall STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Retaining wall 3 AIP - Reinforced Earth Retaining Wall STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Retaining wall 4 AIP - Reinforced Earth Retaining Wall STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Retaining wall 5 AIP - Continuous Bored Piles Retaining Wall STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Gantry SG010 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG009 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG008 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG007 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG006 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG005 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG004 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG003 AIP - Tubular Steel Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Callout
CR Retaining wall 1 STKEY TBC Ref SOR10
UKGXB603
Line
UKSAS001
Line
UKSAS001
Line
UKSAS001
Callout
Showing indicatively Gantries SG001&SG002 at chainages -1460 & -480 respectively AIP - Tubular Steel Cantilever Gantries STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
Page 49: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
UKGXB603
Text Box
Eighton Lodge Slip Road Underbridge OS Grid Ref: 426527E, 557592N STKEY 16441 Structure No. A1/440.90//6 AIP - Widening of Eighton Lodge North & Slip Road Underbridges Ref SOR05
UKGXB603
Text Box
Longbank Bridleway Underbridge OS Grid Ref: 427169E, 557294N STKEY 26280 Structure No. A1/440.80 AIP - Longbank Underpass Ref SOR06
UKGXB603
Text Box
Eighton Lodge North Underbridge OS Grid Ref: 426682E, 557517N STKEY 16440 Structure No. A1/441.00 AIP - Widening of Eighton Lodge North & Slip Road Underbridges Ref SOR05
UKGXB603
Text Box
Eighton Lodge South Underbridge OS Grid Ref: 426801E, 557466N STKEY 8883 Structure No. A1/440.90 AIP - Widening of Eighton Lodge South Bridge Ref SOR05
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Gantry SG017 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Callout
Gantry SG016 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG015 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG014 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG013 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG012 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Callout
Gantry SG011 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
CR Retaining wall 2 STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
CR Retaining wall 3 STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
CR Retaining wall 4 STKEY TBC Ref SOR10
Page 50: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
UKGXB603
Text Box
North Dene Footbridge OS Grid Ref: 427538E, 557089N STKEY 8886 Structure No. A1/440.30 AIP - North Dene Footbridge Ref SOR07
UKGXB603
Text Box
North Side Overbridge OS Grid Ref: 428090E, 556770N STKEY 8887 Structure No. A1/439.70 AIP - North Side Bridge Ref SOR08
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Retaining wall 6 AIP- King Post Retaining Wall STKEY TBC Ref SOR10
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Line
UKGXB603
Callout
Gantry SG020 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Callout
Gantry SG019 AIP - Super Span Truss Portal Gantry STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Callout
Gantry SG018 AIP - Long Span Truss Type Cantilever Gantry STKEY TBC Ref SOR09
UKGXB603
Line
UKGXB603
Line
Page 51: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Appendix B

PLANS & CROSS SECTIONS OF THE PROPOSED NEW RETAINING

WALLS

Page 52: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX B-1

PLANS OF THE NEW RETAINING WALLS

Page 53: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

HEIGHT OF RETAINING WALL - 1

(CONTRACTOR DESIGN)

MIN. = 1.358m

MAX. = 1.5m

AVERAGE = 1.4m

LENGTH = 15m

HEIGHT OF RETAINING WALL - 1

MIN. = 1.5m

MAX. = 2.5m

AVERAGE = 2m

LENGTH = 220m

HEIGHT OF RETAINING WALL - 2

MIN. = 0.5m

MAX. = 1.7m

AVERAGE = 1m

LENGTH = 100m

HEIGHT OF RETAINING WALL - 3

MIN. = 1.5m

MAX. = 6m

AVERAGE = 3.75m

LENGTH = 146m

HEIGHT OF RETAINING WALL - 5

MIN. = 1.5m

MAX. = 3m

AVERAGE = 1.5m

LENGTH = 120m

HEIGHT OF RETAINING WALL - 4

MIN. = 1.5m

MAX. = 4.3m

AVERAGE = 2.9m

LENGTH = 120m

1

1

2

2

KINGSWAY VIADUCT UNDERBRIDGE ;

STRUCTURE KEY 16271

HEIGHT OF CENTER RETAINING WALL - 1

MIN. = 0.3m

MAX. = 0.366m

LENGTH = 125m

A

A

B

B

C

C

D

D

E

E

F

F

G

G

H

H

J

J

A1 NB

A1 SB

K

IN

G

S

W

A

Y

S

O

U

T

H

R

I

V

E

R

T

E

A

M

C

H

O

W

D

E

N

E

B

A

N

K

L

A

M

E

S

L

E

Y

R

O

A

D

JUNCTION 67 - COAL HOUSE

(424955,558553)

SAINSBURY'S

C

O

A

C

H

R

O

A

D

BANESLEY LANE

B

A

N

E

S

L

E

Y

L

A

N

E

A1 N

B

A1 S

B

HEIGHT OF RETAINING WALL - 1

(CONTRACTOR DESIGN)

MIN. = 1.159m

MAX. = 1.5m

AVERAGE = 1.1m

LENGTH = 83m

HEIGHT OF RETAINING WALL - 2

(CONTRACTOR DESIGN)

MIN. = 0.3m

MAX. = 0.5m

AVERAGE = 0.4m

LENGTH = 5m

HEIGHT OF RETAINING WALL - 3

(CONTRACTOR DESIGN)

MIN. = 0.1m

MAX. = 1.5m

AVERAGE = 0.8m

LENGTH = 25m

HEIGHT OF RETAINING WALL - 4

(CONTRACTOR DESIGN)

MIN. = 0.63m

MAX. = 1.5m

AVERAGE = 1.1m

LENGTH = 40m

HEIGHT OF RETAINING WALL - 5

(CONTRACTOR DESIGN)

MIN. = 0.511m

MAX. = 1.5m

AVERAGE = 1.0m

LENGTH = 40m

ALLERDENE CULVERT ;

STRUCTURE KEY 8879

ALLERDENE RAILWAY UNDERBRIDGE ;

STRUCTURE KEY 8880

SMITHY LANE OVERBRIDGE ;

STRUCTURE KEY 16439

3

J

A

1

N

B

A

1 S

B

A

1

N

B

A

1

S

B

SM

IT

HY

LA

NE

S

M

IT

H

Y

LA

N

E

E

A

S

T

C

O

A

S

T

M

A

I

N

L

I

N

E

NOTES

1. THIS DRAWING HIGHLIGHTS RETAINING WALL

STRUCTURAL CONSIDERATION ON A1 BIRTLEY TO

COALHOUSE STRENGTHENING WORKS.

KEY:

PROPOSED RETAINING WALLS ≥ 1.5m HEIGHT

PROPOSED RETAINING CENTER WALL

PROPOSED RETAINING WALLS ≤ 1.5m

(CONTRACTOR DESIGN)

MA

TC

HL

IN

E 1

MA

TC

HLIN

E 1

MA

TC

HLIN

E 2

A1

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

10/04/18 10/04/18

H.Mistry

10/04/18

N.Rawcliffe

10/04/18

P02

1:1000

HE551462 WSP SBR

BR008 DR S 00001

RETAINING WALL STRUCTURES

SHEET 1 OF 3

P01 02/02/18 FOR INFORMATION RA MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FIT FOR COORDINATION S1

AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
280.000
AutoCAD SHX Text
300.000
AutoCAD SHX Text
320.000
AutoCAD SHX Text
340.000
AutoCAD SHX Text
360.000
AutoCAD SHX Text
380.000
AutoCAD SHX Text
400.000
AutoCAD SHX Text
420.000
AutoCAD SHX Text
440.000
AutoCAD SHX Text
460.000
AutoCAD SHX Text
480.000
AutoCAD SHX Text
500.000
AutoCAD SHX Text
520.000
AutoCAD SHX Text
540.000
AutoCAD SHX Text
560.000
AutoCAD SHX Text
580.000
AutoCAD SHX Text
600.000
AutoCAD SHX Text
620.000
AutoCAD SHX Text
640.000
AutoCAD SHX Text
660.000
AutoCAD SHX Text
680.000
AutoCAD SHX Text
700.000
AutoCAD SHX Text
720.000
AutoCAD SHX Text
740.000
AutoCAD SHX Text
760.000
AutoCAD SHX Text
780.000
AutoCAD SHX Text
800.000
AutoCAD SHX Text
820.000
AutoCAD SHX Text
840.000
AutoCAD SHX Text
860.000
AutoCAD SHX Text
880.000
AutoCAD SHX Text
900.000
AutoCAD SHX Text
920.000
AutoCAD SHX Text
940.000
AutoCAD SHX Text
960.000
AutoCAD SHX Text
980.000
AutoCAD SHX Text
1000.000
AutoCAD SHX Text
1020.000
AutoCAD SHX Text
1040.000
AutoCAD SHX Text
1060.000
AutoCAD SHX Text
1080.000
AutoCAD SHX Text
1100.000
AutoCAD SHX Text
1120.000
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
I/R Atop
AutoCAD SHX Text
I/R Atop Wall
AutoCAD SHX Text
R/W
AutoCAD SHX Text
R/W
AutoCAD SHX Text
I/R
AutoCAD SHX Text
R/W
AutoCAD SHX Text
I/R Atop Wall
AutoCAD SHX Text
Wall
AutoCAD SHX Text
TB/SS
AutoCAD SHX Text
TB/SS
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
1120.000
AutoCAD SHX Text
1140.000
AutoCAD SHX Text
1160.000
AutoCAD SHX Text
1180.000
AutoCAD SHX Text
1200.000
AutoCAD SHX Text
1220.000
AutoCAD SHX Text
1240.000
AutoCAD SHX Text
1260.000
AutoCAD SHX Text
1280.000
AutoCAD SHX Text
1300.000
AutoCAD SHX Text
1320.000
AutoCAD SHX Text
1340.000
AutoCAD SHX Text
1360.000
AutoCAD SHX Text
1380.000
AutoCAD SHX Text
1400.000
AutoCAD SHX Text
1420.000
AutoCAD SHX Text
1440.000
AutoCAD SHX Text
1460.000
AutoCAD SHX Text
1480.000
AutoCAD SHX Text
1500.000
AutoCAD SHX Text
1520.000
AutoCAD SHX Text
1540.000
AutoCAD SHX Text
1560.000
AutoCAD SHX Text
1580.000
AutoCAD SHX Text
1600.000
AutoCAD SHX Text
1620.000
AutoCAD SHX Text
1640.000
AutoCAD SHX Text
1660.000
AutoCAD SHX Text
1680.000
AutoCAD SHX Text
1700.000
AutoCAD SHX Text
1720.000
AutoCAD SHX Text
1740.000
AutoCAD SHX Text
1760.000
AutoCAD SHX Text
1780.000
AutoCAD SHX Text
1800.000
AutoCAD SHX Text
1820.000
AutoCAD SHX Text
1840.000
AutoCAD SHX Text
1860.000
AutoCAD SHX Text
1880.000
AutoCAD SHX Text
1900.000
AutoCAD SHX Text
1920.000
AutoCAD SHX Text
1940.000
AutoCAD SHX Text
1960.000
AutoCAD SHX Text
1980.000
AutoCAD SHX Text
2000.000
Page 54: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

EIGHTON LODGE SLIP ROAD UNDERBRIDGE ;

STRUCTURE KEY 16441

HEIGHT OF CENTER RETAINING WALL - 3

MIN. = 0.3m

MAX. = 0.5m

LENGTH = 285m

HEIGHT OF CENTER RETAINING

WALL - 2

MIN. = 0.3m

MAX. = 1m

LENGTH = 270m

3

3

4

4

5

5

6

6

7

7

8

8

9

9

1

8

.9

7

6

0

A1 N

B

A1 S

B

A

1

6

7

D

U

R

H

A

M

R

O

A

D

ANGEL OF THE NORTH

EIGHTON LODGE NORTH UNDERBRIDGE ;

STRUCTURE KEY 16440

EIGHTON LODGE SOUTH UNDERBRIDGE ;

STRUCTURE KEY 8883

LONGBACK BRIDLEWAY UNDERBRIDGE ;

STRUCTURE KEY 26280

HEIGHT OF CENTER RETAINING WALL - 4

MIN. = 0.3m

MAX. = 0.8m

LENGTH = 420m

1

0

1

0

11

11

12

12

13

13

14

14

A1 N

B

A1 S

B

A1 N

B

A1 S

B

JUNCTION 66 - EIGHTON LODGE

(426739,557494)

B

1

2

9

6

L

O

N

G

B

A

N

K

A167 N

EW

CA

ST

LE

BA

NK

NORTH DENE

L

O

N

G

B

A

N

K

MA

TC

HLIN

E 2

MA

TC

HL

IN

E 3

MA

TC

HLIN

E 3

MA

TC

HLIN

E 4

A1

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

10/04/18 10/04/18

H.Mistry

10/04/18

N.Rawcliffe

10/04/18

P02

1:1000

HE551462 WSP SBR

BR008 DR S 00002

RETAINING WALL STRUCTURES

SHEET 2 OF 3

P01 02/02/18 FOR INFORMATION RA MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FIT FOR COORDINATION S1

NOTES

1. THIS DRAWING HIGHLIGHTS RETAINING WALL

STRUCTURAL CONSIDERATION ON A1 BIRTLEY TO

COALHOUSE STRENGTHENING WORKS.

KEY:

PROPOSED RETAINING WALLS ≥ 1.5m HEIGHT

PROPOSED RETAINING CENTER WALL

PROPOSED RETAINING WALLS ≤ 1.5m

(CONTRACTOR DESIGN)

AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
1980.000
AutoCAD SHX Text
2000.000
AutoCAD SHX Text
2020.000
AutoCAD SHX Text
2040.000
AutoCAD SHX Text
2060.000
AutoCAD SHX Text
2080.000
AutoCAD SHX Text
2100.000
AutoCAD SHX Text
2120.000
AutoCAD SHX Text
2140.000
AutoCAD SHX Text
2160.000
AutoCAD SHX Text
2180.000
AutoCAD SHX Text
2200.000
AutoCAD SHX Text
2220.000
AutoCAD SHX Text
2240.000
AutoCAD SHX Text
2260.000
AutoCAD SHX Text
2280.000
AutoCAD SHX Text
2300.000
AutoCAD SHX Text
2320.000
AutoCAD SHX Text
2340.000
AutoCAD SHX Text
2360.000
AutoCAD SHX Text
2380.000
AutoCAD SHX Text
2400.000
AutoCAD SHX Text
2420.000
AutoCAD SHX Text
2440.000
AutoCAD SHX Text
2460.000
AutoCAD SHX Text
2480.000
AutoCAD SHX Text
2500.000
AutoCAD SHX Text
2520.000
AutoCAD SHX Text
2540.000
AutoCAD SHX Text
2560.000
AutoCAD SHX Text
2580.000
AutoCAD SHX Text
2600.000
AutoCAD SHX Text
2620.000
AutoCAD SHX Text
2640.000
AutoCAD SHX Text
2660.000
AutoCAD SHX Text
2680.000
AutoCAD SHX Text
2700.000
AutoCAD SHX Text
2720.000
AutoCAD SHX Text
2740.000
AutoCAD SHX Text
2760.000
AutoCAD SHX Text
2780.000
AutoCAD SHX Text
2800.000
AutoCAD SHX Text
2820.000
AutoCAD SHX Text
2840.000
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
2840.000
AutoCAD SHX Text
2860.000
AutoCAD SHX Text
2880.000
AutoCAD SHX Text
2900.000
AutoCAD SHX Text
2920.000
AutoCAD SHX Text
2940.000
AutoCAD SHX Text
2960.000
AutoCAD SHX Text
2980.000
AutoCAD SHX Text
3000.000
AutoCAD SHX Text
3020.000
AutoCAD SHX Text
3040.000
AutoCAD SHX Text
3060.000
AutoCAD SHX Text
3080.000
AutoCAD SHX Text
3100.000
AutoCAD SHX Text
3120.000
AutoCAD SHX Text
3140.000
AutoCAD SHX Text
3160.000
AutoCAD SHX Text
3180.000
AutoCAD SHX Text
3200.000
AutoCAD SHX Text
3220.000
AutoCAD SHX Text
3240.000
AutoCAD SHX Text
3260.000
AutoCAD SHX Text
3280.000
AutoCAD SHX Text
3300.000
AutoCAD SHX Text
3320.000
AutoCAD SHX Text
3340.000
AutoCAD SHX Text
3360.000
AutoCAD SHX Text
3380.000
AutoCAD SHX Text
3400.000
AutoCAD SHX Text
3420.000
AutoCAD SHX Text
3440.000
AutoCAD SHX Text
3460.000
AutoCAD SHX Text
3480.000
AutoCAD SHX Text
3500.000
AutoCAD SHX Text
3520.000
AutoCAD SHX Text
3540.000
AutoCAD SHX Text
3560.000
AutoCAD SHX Text
3580.000
AutoCAD SHX Text
3600.000
AutoCAD SHX Text
3620.000
AutoCAD SHX Text
3640.000
AutoCAD SHX Text
3660.000
AutoCAD SHX Text
3680.000
AutoCAD SHX Text
3700.000
Page 55: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

HEIGHT OF RETAINING WALL - 6

MIN. = 0.6m

MAX. = 2.556m

AVERAGE = 1.5m

LENGTH = 260m

K

K

L

L

M

M

N

N

NORTH DENE FOOTBRIDGE ;

STRUCTURE KEY 8886

14

14

K

K

L

L

M

M

N

N

A

1

2

3

1

N

B

A

1

2

3

1

S

B

C

R

A

T

H

IE

A1 NB

A1 (M) S

B

A1 NB

A1 SB

A1 NB

A1 SB

HEIGHT OF RETAINING WALL - 6

(CONTRACTOR DESIGN)

MIN. = 0.6m

MAX. = 0.7m

AVERAGE = 0.65m

LENGTH = 20m

M

M

N

N

M

M

N

N

A

1

9

4

(

M

)

N

B

A

1

N

B

A

1

(

M

)

S

B

A1231 NB

A

1

2

3

1

N

B

A

1

2

3

1

S

B

A1231 SB

A

1

(M

) N

B

A

1

(M

) S

B

JUNCTION 65 - BIRTLEY

(428150,556714)

A

1

N

B

A

1

(

M

)

S

B

NORTH SIDE OVERBRIDGE ;

STRUCTURE KEY 8887

MA

TC

HL

IN

E 4

MA

TC

HL

IN

E 5

MA

TC

HLIN

E 5

A1

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

10/04/18 10/04/18

H.Mistry

10/04/18

N.Rawcliffe

10/04/18

P02

1:1000

HE551462 WSP SBR

BR008 DR S 00003

RETAINING WALL STRUCTURES

SHEET 3 OF 3

P01 02/02/18 FOR INFORMATION RA MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FIT FOR COORDINATION S1

NOTES

1. THIS DRAWING HIGHLIGHTS RETAINING WALL

STRUCTURAL CONSIDERATION ON A1 BIRTLEY TO

COALHOUSE STRENGTHENING WORKS.

KEY:

PROPOSED RETAINING WALLS ≥ 1.5m HEIGHT

PROPOSED RETAINING CENTER WALL

PROPOSED RETAINING WALLS ≤ 1.5m

(CONTRACTOR DESIGN)

AutoCAD SHX Text
I/R 1.05mh
AutoCAD SHX Text
Footbridge
AutoCAD SHX Text
I/R 1.05mh
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Drain
AutoCAD SHX Text
Steps
AutoCAD SHX Text
I/R
AutoCAD SHX Text
105.387
AutoCAD SHX Text
105.065
AutoCAD SHX Text
104.842
AutoCAD SHX Text
104.856
AutoCAD SHX Text
104.933
AutoCAD SHX Text
104.925
AutoCAD SHX Text
104.803
AutoCAD SHX Text
104.898
AutoCAD SHX Text
104.796
AutoCAD SHX Text
104.748
AutoCAD SHX Text
104.753
AutoCAD SHX Text
104.815
AutoCAD SHX Text
104.754
AutoCAD SHX Text
104.754
AutoCAD SHX Text
105.099
AutoCAD SHX Text
DP
AutoCAD SHX Text
PO
AutoCAD SHX Text
PO
AutoCAD SHX Text
PO
AutoCAD SHX Text
3700.000
AutoCAD SHX Text
3720.000
AutoCAD SHX Text
3740.000
AutoCAD SHX Text
3760.000
AutoCAD SHX Text
3780.000
AutoCAD SHX Text
3800.000
AutoCAD SHX Text
3820.000
AutoCAD SHX Text
3840.000
AutoCAD SHX Text
3860.000
AutoCAD SHX Text
3880.000
AutoCAD SHX Text
3900.000
AutoCAD SHX Text
3920.000
AutoCAD SHX Text
3940.000
AutoCAD SHX Text
3960.000
AutoCAD SHX Text
3980.000
AutoCAD SHX Text
4000.000
AutoCAD SHX Text
4020.000
AutoCAD SHX Text
4040.000
AutoCAD SHX Text
4060.000
AutoCAD SHX Text
4080.000
AutoCAD SHX Text
4100.000
AutoCAD SHX Text
4120.000
AutoCAD SHX Text
4140.000
AutoCAD SHX Text
4160.000
AutoCAD SHX Text
4180.000
AutoCAD SHX Text
4200.000
AutoCAD SHX Text
4220.000
AutoCAD SHX Text
4240.000
AutoCAD SHX Text
4260.000
AutoCAD SHX Text
4280.000
AutoCAD SHX Text
4300.000
AutoCAD SHX Text
4320.000
AutoCAD SHX Text
4340.000
AutoCAD SHX Text
4360.000
AutoCAD SHX Text
4380.000
AutoCAD SHX Text
4400.000
AutoCAD SHX Text
4420.000
AutoCAD SHX Text
4440.000
AutoCAD SHX Text
4460.000
AutoCAD SHX Text
4480.000
AutoCAD SHX Text
4500.000
AutoCAD SHX Text
4520.000
AutoCAD SHX Text
4540.000
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Bridge Abutment
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Bridge Abutment
AutoCAD SHX Text
105.387
AutoCAD SHX Text
105.065
AutoCAD SHX Text
104.842
AutoCAD SHX Text
104.856
AutoCAD SHX Text
104.933
AutoCAD SHX Text
104.925
AutoCAD SHX Text
104.803
AutoCAD SHX Text
104.898
AutoCAD SHX Text
104.796
AutoCAD SHX Text
104.748
AutoCAD SHX Text
104.753
AutoCAD SHX Text
104.815
AutoCAD SHX Text
104.754
AutoCAD SHX Text
104.754
AutoCAD SHX Text
105.099
AutoCAD SHX Text
4320.000
AutoCAD SHX Text
4340.000
AutoCAD SHX Text
4360.000
AutoCAD SHX Text
4380.000
AutoCAD SHX Text
4400.000
AutoCAD SHX Text
4420.000
AutoCAD SHX Text
4440.000
AutoCAD SHX Text
4460.000
AutoCAD SHX Text
4480.000
AutoCAD SHX Text
4500.000
AutoCAD SHX Text
4520.000
AutoCAD SHX Text
4540.000
AutoCAD SHX Text
4560.000
AutoCAD SHX Text
4580.000
AutoCAD SHX Text
4600.000
AutoCAD SHX Text
4620.000
AutoCAD SHX Text
4640.000
AutoCAD SHX Text
4660.000
AutoCAD SHX Text
4680.000
AutoCAD SHX Text
4700.000
AutoCAD SHX Text
4720.000
AutoCAD SHX Text
4740.000
AutoCAD SHX Text
4760.000
AutoCAD SHX Text
4780.000
AutoCAD SHX Text
4800.000
AutoCAD SHX Text
4820.000
AutoCAD SHX Text
4840.000
AutoCAD SHX Text
4860.000
AutoCAD SHX Text
4880.000
AutoCAD SHX Text
4900.000
AutoCAD SHX Text
4920.000
AutoCAD SHX Text
4940.000
AutoCAD SHX Text
4960.000
AutoCAD SHX Text
4980.000
AutoCAD SHX Text
5000.000
AutoCAD SHX Text
5020.000
AutoCAD SHX Text
5040.000
AutoCAD SHX Text
5060.000
Page 56: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX B-2

CROSS SECTIONS AT THE NEW RETAINING WALL LOCATIONS

Page 57: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

VERGE

1800

VERGE

2500

VERGE

2500

A1 NORTH BOUND

11000

A1 SOUTH BOUND

11000

PROPOSED RETAINING WALL NO. 1 (INDICATIVE)*

PROPOSED RETAINING WALL NO. 2 (INDICATIVE)

EXISTING GROUND PROFILE

PROPOSED GROUND PROFILE

19

22

19

40

RW 950RW 950

VERGE

2500

A1 SOUTH BOUND

15150

VERGE

1800

A1 NORTH BOUND

11000

VERGE

2500

PROPOSED RETAINING WALL NO. 1 (INDICATIVE)*

EXISTING GROUND PROFILE PROPOSED RETAINING WALL,

CONTRACTOR DESIGN (INDICATIVE)*

25

55

50

5

RW 950 RW 950

VERGE

1800

VERGE

1680

SLIP ROAD

7680

VERGE

2510

VERGE

2500

A1 SOUTH BOUND

20305

A1 NORTH BOUND

11000

PROPOSED RETAINING WALL NO. 1 (INDICATIVE)*

EXISTING GROUND PROFILE

3

1

PROPOSED GROUND PROFILE

14

89

RW 965

VERGE

5180

A1 SOUTH BOUND

11000

VERGE

1800

VERGE

2500

SLIP ROAD

9200

VERGE

6210

SLIP RAOD

7825

A1 NORTH BOUND

11000

VERGE

2505

3

1

PROPOSED RETAINING WALL NO. 1 (INDICATIVE)*

EXISTING GROUND PROFILE

PROPOSED GROUND PROFILE

13

49

RW 950

VERGE

2505

SLIP ROAD

8610

VERGE

10325

A1 SOUTH BOUND

11000

A1 NORTH BOUND

11000

VERGE

2500

VERGE

2500

VERGE

1800

1

VERGE

3940

VERGE/SLIP ROAD

9385

2

1

3

1

EXISTING GROUND PROFILE

PROPOSED GROUND PROFILE

34603

PROPOSED RETAINING WALL NO. 3

(INDICATIVE)*

3622

3

1

RW

900

VERGE

2500

VERGE

1800

VERGE

2500

VERGE/SLIP ROAD

9520

VERGE

2515

A1 SOUTH BOUND

11000

VERGE

6145

A1 NORTH BOUND

11000

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

3

1

7050

5325

PROPOSED RETAINING WALL NO. 3

(INDICATIVE)*

3

1

RW

900

SECTION A-A @ Ch340

SCALE 1:150

SECTION B-B @ Ch420

SCALE 1:150

SECTION C-C @ Ch560

SCALE 1:150

SECTION D-D @ Ch620

SCALE 1:150

SECTION E-E @ Ch700

SCALE 1:200

SECTION F-F @ Ch780

SCALE 1:150

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. DateDescription By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

20/04/18 20/04/18

H. Mistry

20/04/18

H. Mistry

20/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 0004

RETAINING WALL

CROSS SECTIONS

(SHEET 1 OF 5)

P01 31/01/18 FOR INFORMATION AS MT HM

P02 20/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

2. ALL LEVELS ARE IN METER A.O.D., UNLESS NOTED OTHERWISE.

3. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS, OR ERRORS.

SEEK CLARIFICATION FROM THE DESIGNER.

4. FOR LOCATION OF CROSS SECTIONS REFER TO LOCATION PLAN

DRAWING NO. T.B.C.

KEY

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALLS ≥ 1.5m HEIGHT

PROPOSED RETAINING WALLS ≤ 1.5m HEIGHT

(CONTRACTOR DESIGN)

Page 58: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

VERGE

2500

VERGE

2500

A1 NORTH BOUND

11000

VERGE

2510

8210 VERGE

2610

SLIP ROAD

8630

VERGE

2510

A1 SOUTH BOUND

11000

13760SLIP ROAD

8610

VERGE

1800

VERGE

2600

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALL NO. 4 (INDICATIVE)*

3

1

3

1

3

1

PROPOSED RETAINING WALL NO. 5 (INDICATIVE)*

2850

4430

VERGE

2500

A1 SOUTH BOUND

11000

VERGE

2500

9830 VERGE

3320

A1 NORTH BOUND

11000

3990 VERGE

2620

VERGE

2600

SLIP ROAD

8620

VERGE

2500

SLIP ROAD

8610

VERGE

2500

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALL NO. 5 (INDICATIVE)*

1

33

1

PROPOSED RETAINING WALL NO. 4 (INDICATIVE)*

2850

3840

SLIP ROAD

8640

VERGE

2610

VERGE

5500

A1 NORTH BOUND

11000

VERGE

2610

VERGE

2500

VERGE

3550

A1 SOUTH BOUND

11000

VERGE

2520

SLIP ROAD

8600

VERGE

2500

PROPOSED RETAINING WALL,

CONTRACTOR DESIGN (INDICATIVE)*

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

1

3

PROPOSED RETAINING WALL,

CONTRACTOR DESIGN (INDICATIVE)*

640

640

VERGE

2500

VERGE

2500

A1 NORTH BOUND

14700

SLIP ROAD / A1 SOUTH BOUND

22850

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALL NO. 6 (INDICATIVE)*

2130

VERGE

2500

A1 SOUTH BOUND

13000

2660VERGE

2560

A1 NORTH BOUND

14700

VERGE

2500

VERGE

2770

SLIP ROAD

12070

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALL NO. 6 (INDICATIVE)*

4

1

2110

A1 SOUTH BOUND

13000

VERGE

3780

VERGE

2500

VERGE

2670

A1 NORTH BOUND

14700

10390VERGE

2570

VERGE

2500

SLIP ROAD

12590

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALL,

CONTRACTOR DESIGN (INDICATIVE)*

4

1

1540

SLIP ROAD / A1 SOUTH BOUND

22850

VERGE

2500

A1 NORTH BOUND

14700

VERGE

2500

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALL, CONTRACTOR

DESIGN (INDICATIVE)*

740

NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED OTHERWISE.

2. ALL LEVELS ARE IN METER A.O.D., UNLESS NOTED OTHERWISE.

3. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS, OR ERRORS.

SEEK CLARIFICATION FROM THE DESIGNER.

4. FOR LOCATION OF CROSS SECTIONS REFER TO LOCATION PLAN

DRAWING NO. T.B.C.

SECTION G-G @ Ch940

SCALE 1:200

SECTION H-H @ Ch1000

SCALE 1:200

SECTION J-J @ Ch1100

SCALE 1:200

SECTION K-K @ Ch4120

SCALE 1:200

SECTION L-L @ Ch4200

SCALE 1:200

SECTION M-M @ Ch4360

SCALE 1:200

SECTION N-N @ Ch4400

SCALE 1:200

KEY

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

PROPOSED RETAINING WALLS ≥ 1.5m HEIGHT

PROPOSED RETAINING WALLS ≤ 1.5m HEIGHT

(CONTRACTOR DESIGN)

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. DateDescription By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

20/04/18 20/04/18

H. Mistry

20/04/18

H. Mistry

20/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 0005

RETAINING WALL

CROSS SECTIONS

(SHEET 2 OF 5)

P01 31/01/18 FOR INFORMATION AS MT HM

P02 20/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

Page 59: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

VERGE

2500

A1 SOUTH BOUND

18320

PROPOSED GROUND PROFILE

EXISTING GROUND PROFILE

CENTRAL RESERVE

1800

A1 NORTH BOUND

16390

VERGE

2500

SECTION 1-1 @ Ch0520

SCALE 1:200

VERGE

2500

SLIP ROAD

9680

VERGE

3600

A1 SOUTH BOUND

11000

CENTRAL RESERVE

1800

A1 NORTH BOUND

11000

VERGE

5030

SLIP ROAD

7710

VERGE

2510

SECTION 2-2 @ Ch0600

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

16700

CENTRAL RESERVE

3040

A1 NORTH BOUND

14700

VERGE

2500

SECTION 3-3 @ Ch2000

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

16700

CENTRAL RESERVE

2500

A1 NORTH BOUND

14700

VERGE

2500

SECTION 4-4 @ Ch2100

SCALE 1:200

CENTRAL RESERVE

2500

A1 NORTH BOUND

14700

VERGE

2500

A1 SOUTH BOUND

20680

VERGE

2500

SECTION 5-5 @ Ch2200

SCALE 1:200

329

314

888

695

379

A1

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. DateDescription By

Chk'dApp'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etre

s

10

01

00

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

02/02/18 02/02/18

H.Mistry

02/02/18

N.Rawcliffe

02/02/18

P01

1:1000

HE551462 WSP SBR

BR008 DR S 0006

CENTRAL RESERVE RETAINING WALLS

CROSS SECTIONS

SHEET 1 OF 3

P01

A1

A1 BIRTLEY TO COALHOUSE

FIT FOR COORDINATION S1

NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS

NOTED OTHERWISE.

2. ALL LEVELS ARE IN METER A.O.D., UNLESS NOTED

OTHERWISE.

3. DO NOT SCALE IN CASE OF ANY DOUBTS,

OMISSIONS, OR ERRORS. SEEK CLARIFICATION

FROM THE DESIGNER.

4. FOR LOCATION OF CROSS SECTIONS REFER TO

DRAWING NO. T.B.C.

KEY

PROPOSED GROUND PROFILE:

EXISTING GROUND PROFILE:

Page 60: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

02/02/18 02/02/18

H.Mistry

02/02/18

N.Rawcliffe

02/02/18

P01

1:1000

HE551462 WSP SBR

BR008 DR S 00007

CENTRAL RESERVE RETAINING WALLS

CROSS SECTIONS

SHEET 2 OF 3

P01

A1

A1 BIRTLEY TO COALHOUSE

FIT FOR COORDINATION S1

NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS

NOTED OTHERWISE.

2. ALL LEVELS ARE IN METER A.O.D., UNLESS NOTED

OTHERWISE.

3. DO NOT SCALE IN CASE OF ANY DOUBTS,

OMISSIONS, OR ERRORS. SEEK CLARIFICATION

FROM THE DESIGNER.

4. FOR LOCATION OF CROSS SECTIONS REFER TO

DRAWING NO. T.B.C.

KEY

PROPOSED GROUND PROFILE:

EXISTING GROUND PROFILE:

SECTION 6-6 @ Ch2380

SCALE 1:200

CENTRAL RESERVE

2500

A1 NORTH BOUND

14700

VERGE

2500

A1 SOUTH BOUND

24000

VERGE

2500

VERGE

2500

A1 NORTH BOUND

14700

CENTRAL RESERVE

2500

A1 SOUTH BOUND

16700

VERGE

2500

SLIP ROAD

9320

VERGE

3310

VERGE

2500

SECTION 7-7 @ Ch2500

SCALE 1:200

A1 SOUTH BOUND

16700

CENTRAL RESERVE

2500

A1 NORTH BOUND

11000

VERGE

3880

SLIP ROAD

8350

VERGE

2500

SECTION 8-8 @ Ch2600

SCALE 1:200

SECTION 9-9 @ Ch2720

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

16700

CENTRAL RESERVE

2500

A1 NORTH BOUND

11000

VERGE

2500

SECTION 10-10 @ Ch3300

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

16700

CENTRAL RESERVE

3650

A1 NORTH BOUND

11000

VERGE

2500

20

1

48

3

41

3

27

0

40

0

Page 61: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

A1

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

02/02/18 02/02/18

H.Mistry

02/02/18

N.Rawcliffe

02/02/18

P01

1:1000

HE551462 WSP SBR

BR008 DR S 00008

CENTRAL RESERVE RETAINING WALLS

CROSS SECTIONS

SHEET 3 OF 3

P01

A1

A1 BIRTLEY TO COALHOUSE

FIT FOR COORDINATION S1

NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS

NOTED OTHERWISE.

2. ALL LEVELS ARE IN METER A.O.D., UNLESS NOTED

OTHERWISE.

3. DO NOT SCALE IN CASE OF ANY DOUBTS,

OMISSIONS, OR ERRORS. SEEK CLARIFICATION

FROM THE DESIGNER.

4. FOR LOCATION OF CROSS SECTIONS REFER TO

DRAWING NO. T.B.C.

KEY

PROPOSED GROUND PROFILE:

EXISTING GROUND PROFILE:

SECTION 11-11 @ Ch3400

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

23332

CENTRAL RESERVE

3650

A1 NORTH BOUND

21030

VERGE

2500

SECTION 12-12 @ Ch3500

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

20350

CENTRAL RESERVE

3562

A1 NORTH BOUND

14700

VERGE

2500

SECTION 13-13 @ Ch3600

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

20350

CENTRAL RESERVE

2500

A1 NORTH BOUND

14700

VERGE

2500

SECTION 14-14 @ Ch3680

SCALE 1:200

VERGE

2500

A1 SOUTH BOUND

18690

CENTRAL RESERVE

2500

A1 NORTH BOUND

14700

VERGE

2500

62

5

75

5

52

4

34

7

Page 62: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Appendix C

STATUTORY UNDERTAKES INFORMATION

Page 63: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX C-1

STATUTORY UNDERTAKERS DRAWINGS

Page 64: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
Page 65: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
Page 66: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
Page 67: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX C-2

TABULATED OVERVIEW SERVICES IMPACTING THE NEW RETAINING WALLS

Page 68: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Table C 1Services Potentially Impacted by the Proposed New Retaining Walls

NUMBER CHAINAGE ON MAINLINE LOCATION EXISTING SERVICES PROPOSED DIVERSIONARY WORKS

Retaining Wall 1

0+325 to 0+643

Mainline/ A1 Southbound

No services known to be carried through the proposed Retaining Wall 1 (TBC)

No proposed services identified at the proposed Retaining Wall 1 (TBC)

Retaining Wall 2

0+325 to 0+426

Mainline/ A1 Northbound

No services known to be carried through the proposed Retaining Wall 2 (TBC)

No proposed services identified at the proposed Retaining Wall 2 (TBC)

Retaining Wall 3

0+625 to 0+796

Mainline/ A1 Northbound

Northumbria Water Abandoned (NW101) is buried on Retaining Wall 3 at approx. Chainage 0+660. The service located on J67 (Coal House). Runs along the North side of the roundabout from Chowdene Bank crossing the SB exit slip, main carriageway & NB entry slip.

Northern Gas Low Pressure (NG101) is buried adjacent to Retaining Wall 3 at approx. Chainage 0+795. The proposed service will be located on J67 (Coal House) roundabout. Crosses NB entry slip near exit from roundabout.

Northern Powergrid Cable (NP101) is buried adjacent to Retaining Wall 3 at approx. Chainage 0+795. The proposed service will be located on J67 (Coal House) roundabout. Crosses NB entry slip near roundabout and goes on to run along west side of roundabout.

British Telecommunications Duct (BT101) is buried adjacent to Retaining Wall 3 at approx. Chainage 0+795. The proposed service will be located on J67 (Coal House) roundabout. BT apparatus runs along West side of roundabout. Running North to South.

(NW101) Abandoned sewer from Banesley Lane, Lady Park.

Norther Gas New Main 124m x 180mm PE LP. The proposed service will be buried adjacent to Retaining Wall 3 at approx.. Chainage 0+795. The proposed service will be located on J67 (Coal House) roundabout. Runs along outside of roundabout and runs up West side of Kingsway South.

(NG101) Abandon 16m x 6” SI – BTMR and lay 26m x 180mm PE LP

(BT101) Openreach plan to be diverted out of affected area.

(V101) Construct FW6 chamber in new footway. Demolish existing chamber and run split duct through to new chamber. Lower ducting where carriageway is to widened. Lay 2 x 96mm duct configuration in new footway from existing chamber to proposed FW6.

(NW105) Water Main Diversion has been proposed to be installed (TBC)

Page 69: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

NUMBER CHAINAGE ON MAINLINE LOCATION EXISTING SERVICES PROPOSED DIVERSIONARY WORKS

Virgin Media Cable (V101) is buried adjacent to Retaining Wall 3 at approx. Chainage 0+795. The proposed service will be located on J67 (Coal House) roundabout. Runs along West side of roundabout, crossing by the exit from roundabout on the NB entry slip.

Northumbria Water Treated (NW105) is buried adjacent to Retaining Wall 3 at approx. Chainage 0+795. The proposed service will be located on J67 (Coal House) roundabout. Runs along West side of roundabout.

Retaining Wall 4

0+940 to 1+100

Mainline/ A1 Northbound

Northumbria Water Abandoned (NW104) is buried on Retaining Wall 4 at approx. Chainage 0+965. The service located on J67 (Coal House). Crosses main carriageway and two slip roads just South of junction.

Northern Gas Low Pressure (NG104) is buried on Retaining Wall 4 at approx.. Chainage 1+060. The service located on J67 (Coal House). Crosses SB entry slip, main carriageway and NB exit slip.

(NW 104) Abandoned sewer from Lamesley.

Retaining Wall 5

0+940 to 1+105

Mainline/ A1 Southbound

Northumbria Water Abandoned (NW104) is buried on Retaining Wall 5 at approx.. Chainage 0+950. The service located on J67 (Coal House). Crosses main carriageway and two slip roads just South of junction.

(NW 104) Abandoned sewer from Lamesley.

Retaining Wall 6

4+114 to 4+410

Mainline/ A1 Southbound

Northern Powergrid Cable (NP111) is buried on Retaining Wall 6 at approx. Chainage 4+250. The service located on North of J65 (Birtley). Crosses the carriageway next to Bowes inline Hotel and runs along Northside (housing estate).

(NW114) Water Main Diversion has been proposed to be installed (TBC)

(BT109) British Telecommunication Duct to be slewed out of the proposed road widening

Page 70: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

NUMBER CHAINAGE ON MAINLINE LOCATION EXISTING SERVICES PROPOSED DIVERSIONARY WORKS

Northumbia Water Distribution (NW 114) is buried on Retaining Wall 6 at approx.. Chainage 4+245.The service located on Bowes Incline Hotel. Crosses main carriageway and slip roads near hotel.

British Telecommunications Duct (BT109) is buried on Retaining Wall 6 at approx. Chainage 4+400. The service located on J65 (Birtley) Southbound exit slip. Runs along the slip road.

CR Retaining Wall 1

0+515 to 0+615

Central Reserve

No services known to be carried through the proposed CR Retaining Wall 1 (TBC)

No proposed services identified at the proposed Retaining Wall 1 (TBC)

CR Retaining Wall 2

1+950 to 2+220

Central Reserve

No services known to be carried through the proposed CR Retaining Wall 2 (TBC)

No proposed services identified at the proposed Retaining Wall 2 (TBC)

CR Retaining Wall 3

2+370 to 2+735

Central Reserve

No services known to be carried through the proposed CR Retaining Wall 3 (TBC)

No proposed services identified at the proposed Retaining Wall 3 (TBC)

CR Retaining Wall 4

3+270 to 3+690

Central Reserve

Northern Gas low pressure (NG 110) is buried on CR Retaining Wall 4 at approx. Chainage 3+380. The service located on South of J66 (Eighton Lodge). Crosses SB entry slip, main carriageway and NB exit slip road.

Page 71: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Appendix D

RETAINING WALLS PROPOSED GENERAL ARRANGEMENT

DRAWINGS

Page 72: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX D-1

RETAINING WALL 1 (RW1) GENERAL ARRANGEMENT

Page 73: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

0

+

3

2

0

0

+

3

4

0

0

+

3

6

0

0

+

3

8

0

0

+

4

0

0

0

+

4

2

0

0

+

4

4

0

0

+

4

6

0

0

+

4

8

0

0

+

5

0

0

0

+

5

2

0

0

+

5

4

0

0+

560

0+

580

0+

600

0+

620

0+

640

0+

660

0

+

3

2

5

0

+

4

2

5

H

3

5

B

H

4

0

1

H

3

5

B

H

4

0

0

H

3

5

B

H

4

A

1 N

B

A

1 S

B

19

.1

50

TOP OF RETAINING

WALL (m AOD)

17

.2

86

EXISTING GROUND

LEVEL BEHIND WALL

(m AOD)

CHAINAGE

(METRE)

CH

. 0

+3

25

18

.8

92

16

.9

38

CH

. 0

+3

40

18

.5

38

16

.3

81

CH

. 0

+3

60

18

.2

55

15

.8

70

CH

. 0

+3

80

18

.0

02

15

.3

94

CH

. 0

+4

00

17

.7

36

15

.3

04

CH

. 0

+4

20

17

.5

06

15

.0

12

CH

. 0

+4

40

17

.3

33

14

.7

83

CH

. 0

+4

60

17

.0

52

14

.6

84

CH

. 0

+4

80

16

.8

28

14

.5

88

CH

. 0

+5

00

16

.6

78

14

.5

49

CH

. 0

+5

20

16

.5

27

14

.6

36

CH

. 0

+5

40

16

.4

29

14

.8

56

CH

. 0

+5

60

16

.3

87

14

.8

13

CH

. 0

+5

80

16

.2

85

14

.9

10

CH

. 0

+6

00

15

.9

35

14

.3

69

CH

. 0

+6

20

15

.2

94

13

.8

32

CH

. 0

+6

40

TOP OF RETAINING WALL LEVEL

BOTTOM OF WALL FOOTING LEVEL

BOTTOM OF

RETAINING WALL

(m AOD)

16

.1

59

16

.1

59

15

.8

81

15

.8

81

15

.6

25

15

.6

25

15

.3

70

15

.3

70

15

.1

32

15

.1

32

14

.8

94

14

.8

94

14

.8

49

14

.8

49

14

.8

04

14

.8

04

14

.6

58

14

.6

58

14

.5

12

14

.5

12

14

.3

97

14

.3

97

14

.2

83

14

.2

83

14

.2

33

14

.2

33

14

.1

84

14

.1

84

14

.1

36

14

.1

36

14

.0

88

14

.0

88

14

.0

68

14

.0

68

14

.0

49

14

.0

49

14

.0

49

14

.0

49

14

.0

92

14

.0

92

14

.1

36

14

.1

36

14

.2

46

14

.2

46

19

.0

64

18

.9

78

18

.8

21

18

.8

21

18

.7

85

18

.7

50

18

.7

15

18

.6

79

18

.6

44

18

.6

08

18

.5

73

18

.5

09

18

.4

81

18

.4

53

18

.4

24

18

.3

96

18

.3

68

18

.3

39

18

.3

11

18

.2

83

18

.2

29

18

.2

04

18

.1

79

18

.1

53

18

.1

22

18

.1

03

18

.0

77

18

.0

52

18

.0

27

17

.9

75

17

.9

48

17

.9

22

17

.8

95

17

.8

69

17

.8

42

17

.8

15

17

.7

89

17

.6

62

17

.7

13

17

.6

90

17

.6

67

17

.6

44

17

.6

21

17

.5

98

17

.5

75

17

.5

52

17

.5

29

17

.4

88

17

.4

71

17

.4

54

17

.4

36

17

.4

19

17

.4

02

14

.3

84

17

.3

67

17

.3

50

17

.3

04

17

.2

76

17

.2

48

17

.2

20

17

.1

92

17

.1

64

17

.1

36

17

.1

08

17

.0

80

17

.0

29

17

.0

07

16

.9

84

16

.9

62

16

.9

40

16

.9

17

16

.8

95

16

.8

72

16

.8

50

16

.8

13

16

.7

98

16

.7

83

16

.7

68

16

.7

53

16

.7

38

16

.7

23

16

.7

08

16

.6

93

16

.6

61

16

.6

45

16

.6

29

16

.6

13

16

.5

97

16

.5

81

16

.5

65

16

.5

49

16

.5

33

16

.5

08

16

.4

99

16

.4

90

16

.4

81

16

.4

73

16

.4

64

16

.4

55

16

.4

46

16

.4

37

16

.4

24

16

.2

20

16

.4

16

16

.4

12

16

.4

08

16

.4

03

16

.3

99

16

.3

95

16

.3

91

16

.3

76

16

.3

66

16

.3

56

16

.3

46

16

.3

36

16

.3

26

16

.3

15

16

.3

05

16

.2

95

16

.2

50

16

.2

15

16

.1

80

16

.1

45

16

.1

10

16

.0

75

16

.0

40

16

.0

05

15

.9

70

15

.8

70

15

.8

06

15

.7

42

15

.6

78

15

.6

14

15

.5

50

15

.4

86

15

.4

22

15

.3

58

BOTTOM OF RETAINING HEIGHT

1990mm WIDTH PRECAST CONCRETE WALL

10mm CONSTRUCTION JOINT IN EVERY 2m

CONTRACTOR DESIGN

ELEMENT* REINFORCED CONCRETE CANTILEVER RETAINING WALL CONTRACTOR DESIGN ELEMENT*

1

1

VERGE A1 SOUTHBOUND C/W

(PROPOSED)

PROPOSED NEW STRUCTURAL BACKFILL

TO COMPRISE CLASS 6N MATERIAL

TOP OF RETAINING WALL

CONCRETE

RETAINING WALL

EXISTING GROUND

BEHIND WALL

VA

RIE

S

VARIES

BOTTOM OF RETAINING WALL

50

0

PROPRIETARY PARAPET

SYSTEM ACCORDING TO

EN 1317. CONTAINMENT

LEVEL N2 (TBC).

TR

AF

FIC

F

AC

E

PLAN OF RETAINING WALL 1

SCALE 1:750

ELEVATION OF RETAINING WALL 1

SCALE 1:500

A

A

RETAINING

WALL 1

TYPICAL SECTION A-A

SCALE 1:25

RETAINING WALL - 1 LOCATION

GENERAL NOTES

1. STRUCTURAL RETAINING WALL DETAILS PROVIDED ON THIS

DRAWING IS INDICATIVE ONLY BASED ON LIMITED

INFORMATION AVAILABLE TODAY.

2. THE SIZE OF STRUCTURAL ELEMENTS ARE BASED ON

PRELIMINARY CALCULATION AND PREVIOUS SIMILAR TYPE

WORKS. ALL INFORMATION IS SUBJECT TO DETAILED DESIGN

PRIOR TO FINAL CONFIRMATION.

3. DETAILS PROVIDED ARE FOR INFORMATION ONLY. INDICATIVE

CONSTRUCTION COST ESTIMATES ARE BASED ON PREVIOUS

SIMILAR TYPE WORKS.

4. THE FOLLOWING CRITICAL INFORMATION IS REQUIRED TO

VERIFY THE FEASIBILITY OF THE PROPOSED OPTION AND

DEVELOPED THIS FURTHER AT DETAILED DESIGN (IF

PREFERRED)

4.1. TOPOGRAPHICAL SURVEY - CONFIRM GEOMETRIC

PARAMETER AND SITE CONSTRAINTS

4.2. SITE INVESTIGATION INFORMATION - CONFIRM

FOUNDATION PARAMETERS

4.3. LIAISON WITH HIGHWAY ENGLAND - CONFIRM

STRUCTURAL REQUIREMENTS

4.4. LIAISON WITH STATUTORY UNDERTAKERS - CONFIRM

EXISTING/ NEW SERVICES IMPACTED BY THE WORKS.

5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

OTHERWISE.

6. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

7. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS OR

ERRORS SEEK DESIGNER CLARIFICATION.

8. FOR BOREHOLE INFORMATION REFER TO GROUND

INVESTIGATION REPORT

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

10/04/18 10/04/18

H. Mistry

10/04/18

H. Mistry

10/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 00009

RETAINING WALL 1

(STKEY 00001)

GENERAL ARRANGEMENT

P01 31/01/18 FOR INFORMATION AS MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

LIMITS OF LAND TO BE ACQUIRED OR USED

PERMANENTLY OR TEMPORARILY

PROPOSED LAYOUT- DESIGN FIX 3: REV 2

(16/08/2017)

LAND TO BE USED FOR CONSTRUCTION,

MAINTENANCE AND OPERATION

CURRENTLY OWNED BY SECRETARY OF

STATE

LAND TO BE PERMANENTLY ACQUIRED FOR

CONSTRUCTION, MAINTENANCE AND

OPERATION

THIRD PARTY LAND TEMPORARILY

REQUIRED DURING CONSTRUCTION

AREA NOT INCLUDED WITHIN THE DCO

BOUNDARY

KEY

IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS

DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS

RISK REFERENCE:

REF 014 - LIFTING AND INSTALLATION OF HEAVY PRECAST CONCRETE UNITS

REF 015 - POORER ANTICIPATED GROUND CONDITIONS LEADING TO EXCESSIVE STRUCTURAL MOVEMENT

REF 016 - PROPOSED STRUCTURAL WORKS CAUSING INSTABILITY TO EXISTING EARTHWORKS

REF 017 - PROPOSED STRUCTURAL BEING ADVERSELY IMPACTED BY COLLAPSE OF COAL MINE WORKING

BELOW FOUNDATIONS

INDICATES A RESIDUAL RISK AS A WARNING

SAFETY, HEALTH AND ENVIRONMENTAL SYMBOL LEGEND

*CONTRACTOR SHALL BE RESPONSIBLE FOR THE

DESIGN OF RETAINING STRUCTURES LESS THAN 1.5m

RETAINED HEIGHT. THE STRUCTURE SHALL HAVE A

SMOOTH TRAFFIC FACE IN ACCORDANCE WITH TD19/06.

THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR

THE PROVISION OF A SMOOTH TRANSITION BETWEEN

THE RETAINING STRUCTURE ≤1.5m & ≥1.5m

CONTRACTOR DESIGN

ELEMENT

CONTRACTOR

DESIGN ELEMENT

Page 74: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX D-2

RETAINING WALL 2 (RW2) GENERAL ARRANGEMENT

Page 75: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

1

0

0

3

0

0

0

+

2

2

0

0

+

2

4

0

0

+

2

6

0

0

+

2

8

0

0

+

3

0

0

0

+

3

2

0

0

+

3

4

0

0

+

3

6

0

0

+

3

8

0

0

+

4

0

0

0

+

4

2

0

0

+

4

4

0

0

+

4

6

0

0

+

4

8

0

0

+

5

0

0

0

+

5

2

0

0

+

5

4

0

0+

560

0+

580

0

+

3

2

5

0

+

4

2

5

A

1 N

B

A

1 S

B

H35 BH5H35 BH5

PROPOSED

CONTRACTOR

DESIGN*

19

.6

84

CH

. 0

+3

40

18

.8

52

18

.6

02

CHAINAGE

TOP OF SHEET PILE LEVEL

(METRE)

TOP OF CAPPING BEAM LEVEL

(m AOD)

(m AOD)

20

.0

01

CH

. 0

+3

25

19

.7

51

19

.4

34

CH

. 0

+3

60

CH

. 0

+3

80

18

.5

44

18

.2

94

18

.1

90

CH

. 0

+4

00

17

.9

40

CH

. 0

+4

20

CH

. 0

+4

25

PROPOSED TOE LEVEL

(m AOD)

7.4

50

7.4

50

6.9

15

6.0

16

8.8

28

6.9

15

EXISTING GROUND LEVEL

(m AOD)

18

.0

78

17

.8

87

17

.7

73

17

.5

84

17

.6

37

6.0

16

8.8

28

19

.2

55

19

.0

05

6.9

15

6.9

15

17

.9

04

18

.1

06

17

.6

37

EXISTING GROUND

LEVEL

TOP OF PROPOSED

SHEET PILE LEVEL

SHEET PILE TOE

LEVEL

SHEET PILE RETAINING WALL

VA

RIE

S

SE

E E

LE

VA

TIO

N F

OR

L

EN

GT

H

PROPRIETARY PARAPET

SYSTEM ACCORDING TO

EN 1317. CONTAINMENT

LEVEL N2 (TBC).

TR

AF

FIC

F

AC

E

TOP OF SHEET PILE

CAPPING BEAM

A1 NORTH BOUND

TOE OF SHEET PILE

EXISTING GROUND

BEYOND

WEEP HOLE

(APPROVED

SYSTEM T.B.C)

52

5

50

0

25

25

960

25

25

25mm FALL

*

PLAN OF RETAINING WALL 2

SCALE 1:750

SHEET PILE

ELEVATION OF RETAINING WALL 2

SCALE 1:250

RETAINING WALL - 2 LOCATION

SECTION A-A

SCALE 1:25

A

A

TYPICAL DETAIL OF AZ SHEET PILES

SCALE NTS

CAPPING BEAM DETAILS (INDICATIVE)

SCALE 1:10

PILE TYPESHEET PILE SECTION MODULUS

(cm³/m)

WALL THICKNESS

(cm)

AZ 32-750 3200 511

SHEET PILE TABLE

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

10/04/18 10/04/18

H. Mistry

10/04/18

H. Mistry

10/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 00010

RETAINING WALL 2

(STKEY 00002)

GENERAL ARRANGEMENT

P01 31/01/18 FOR INFORMATION AS MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

*

GENERAL NOTES

1. STRUCTURAL RETAINING WALL DETAILS PROVIDED ON THIS

DRAWING IS INDICATIVE ONLY BASED ON LIMITED

INFORMATION AVAILABLE TODAY.

2. THE SIZE OF STRUCTURAL ELEMENTS ARE BASED ON

PRELIMINARY CALCULATION AND PREVIOUS SIMILAR TYPE

WORKS. ALL INFORMATION IS SUBJECT TO DETAILED DESIGN

PRIOR TO FINAL CONFIRMATION.

3. DETAILS PROVIDED ARE FOR INFORMATION ONLY. INDICATIVE

CONSTRUCTION COST ESTIMATES ARE BASED ON PREVIOUS

SIMILAR TYPE WORKS.

4. THE FOLLOWING CRITICAL INFORMATION IS REQUIRED TO

VERIFY THE FEASIBILITY OF THE PROPOSED OPTION AND

DEVELOPED THIS FURTHER AT DETAILED DESIGN (IF

PREFERRED)

4.1. TOPOGRAPHICAL SURVEY - CONFIRM GEOMETRIC

PARAMETER AND SITE CONSTRAINTS

4.2. SITE INVESTIGATION INFORMATION - CONFIRM

FOUNDATION PARAMETERS

4.3. LIAISON WITH HIGHWAY ENGLAND - CONFIRM

STRUCTURAL REQUIREMENTS

4.4. LIAISON WITH STATUTORY UNDERTAKERS - CONFIRM

EXISTING/ NEW SERVICES IMPACTED BY THE WORKS.

5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

OTHERWISE.

6. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

7. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS OR

ERRORS SEEK DESIGNER CLARIFICATION.

8. FOR BOREHOLE INFORMATION REFER TO GROUND

INVESTIGATION REPORT

LIMITS OF LAND TO BE ACQUIRED OR USED

PERMANENTLY OR TEMPORARILY

PROPOSED LAYOUT- DESIGN FIX 3: REV 2

(16/08/2017)

LAND TO BE USED FOR CONSTRUCTION,

MAINTENANCE AND OPERATION

CURRENTLY OWNED BY SECRETARY OF

STATE

LAND TO BE PERMANENTLY ACQUIRED FOR

CONSTRUCTION, MAINTENANCE AND

OPERATION

THIRD PARTY LAND TEMPORARILY

REQUIRED DURING CONSTRUCTION

AREA NOT INCLUDED WITHIN THE DCO

BOUNDARY

KEY

IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS

DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS

RISK REFERENCE:

REF 004 - POORER ANTICIPATED GROUND CONDITIONS LEADING TO EXCESSIVE STRUCTURAL MOVEMENT

REF 005 - PROPOSED STRUCTURAL WORKS CAUSING INSTABILITY TO EXISTING EARTHWORKS

REF 006 - PROPOSED STRUCTURE BEING ADVERSELY IMPACTED BY COLLAPSE OF COAL MINE WORKING BELOW

FOUNDATION

REF 007 - CONTAMINATED LAND

REF 008 - HIGHER THAN ANTICIPATED GROUNDWATER LEADING TO EXCESSIVE STRUCTURAL MOVEMENT

INDICATES A RESIDUAL RISK AS A WARNING

SAFETY, HEALTH AND ENVIRONMENTAL SYMBOL LEGEND

*CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN

OF RETAINING STRUCTURES LESS THAN 1.5m RETAINED

HEIGHT. THE STRUCTURE SHALL HAVE A SMOOTH

TRAFFIC FACE IN ACCORDANCE WITH TD19/06. THE

CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE

PROVISION OF A SMOOTH TRANSITION BETWEEN THE

RETAINING STRUCTURE ≤1.5m & ≥1.5m

Page 76: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX D-3

RETAINING WALL 3 (RW3) GENERAL ARRANGEMENT

Page 77: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

0+

580

0+

600

0+

620

0+

640

0+

660

0+

680

0+

700

0+

720

0+

740

0+

760

0+

780

0+

800

0+

795

0+

625

0+

690

0+

710

0+

730

0+

750

0+

770

0+

790

H

3

5

B

H

4

0

0

H

3

8

B

H

6

0

5

A

H

3

8

B

H

6

0

5

H

3

5

B

H

3

H

5

0

B

H

9

0

5

H

5

0

B

H

9

0

6

H

5

0

B

H

9

0

3

T

H

5

0

B

H

9

0

1

H

3

8

B

H

6

0

4

CH

. 0+

640

15.868

CH

. 0+

625

15.909

15.863

CH

. 0+

680

16.100

CH

. 0+

700

16.306

CH

. 0+

720

CH

. 0+

740

16.013

15.313

13.668

12.600

11.786

16.688

11.288

CH

. 0+

760

16.730

11.100

CH

. 0+

780

16.444

11.204

TOP OF RETAINING

STRUCTURE (m AOD)

CHAINAGE

(METRE)

PROPOSED DESIGNED

RETAINING HEIGHT LEVEL

(m AOD)

15.811

CH

. 0+

660

14.611

CH

. 0+

795

14.984

11.429

PROPOSED DESIGNED BOTTOM

OF LEVELLING PAD LEVEL

(m AOD)

13.140

13.140

12.905

12.905

12.670

12.670

12.400

12.400

12.134

12.134

11.867

11.867

11.600

11.600

11.396

11.396

11.193

11.193

10.989

10.989

10.786

10.786

10.537

10.537

10.288

10.288

10.194

10.194

10.100

10.100

10.100

10.100

10.152

10.152

10.204

10.204

10.316

10.316

CH

. 0+

730

CH

. 0+

750

CH

. 0+

770

CH

. 0+

790

CH

. 0+

630

CH

. 0+

635

CH

. 0+

650

CH

. 0+

670

CH

. 0+

685

CH

. 0+

690

CH

. 0+

695

CH

. 0+

705

CH

. 0+

710

CH

. 0+

715

REINFORCEMENT EARTH RETAINING WALLPROPOSED CONTRACTOR DESIGN*

15.844

14.847

VARIES

A1 NORTH BOUND VERGE

MIN

50

0

VA

RIE

S

TOP OF RE WALL

PROPOSED SLIP ROAD

BOTTOM OF RE WALL (VARIES)

LEVELLING PAD

FACING PANELS

REINFORCING STRIPS

GROUND IMPROVEMENT REQUIRED

BENEATH THE PROPOSED RETAINING WALL

BACK FILL

PRECAST CAPPING UNIT

IN-SITU PARAPET SUPPORT SLAB

SELECTED GRANULAR MATERIAL

PROPRIETARY PARAPET SYSTEM

ACCORDING TO EN 1317

CONTAINMENT LEVEL N2 (TBC)

PROPRIETARY BARRIER SYSTEM

ACCORDING TO EN 1317

CONTAINMENT LEVEL N2 (TBC)

PLAN OF RETAINING WALL 3

SCALE 1:500

A

A

RETAINING WALL 3

ELEVATION OF RETAINING WALL 3

SCALE 1:300

TYPICAL SECTION A-A

SCALE 1:50

LOCATION OF RETAINING WALL 3

SCALE NTS

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

10/04/18 10/04/18

H. Mistry

10/04/18

H. Mistry

10/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 00011

RETAINING WALL 3

(STKEY 00003)

GENERAL ARRANGEMENT

P01 30/01/18 FOR INFORMATION AS MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

RETAINING WALL - 3 LOCATION

GENERAL NOTES

1. STRUCTURAL RETAINING WALL DETAILS PROVIDED ON THIS

DRAWING IS INDICATIVE ONLY BASED ON LIMITED

INFORMATION AVAILABLE TODAY.

2. THE SIZE OF STRUCTURAL ELEMENTS ARE BASED ON

PRELIMINARY CALCULATION AND PREVIOUS SIMILAR TYPE

WORKS. ALL INFORMATION IS SUBJECT TO DETAILED DESIGN

PRIOR TO FINAL CONFIRMATION.

3. DETAILS PROVIDED ARE FOR INFORMATION ONLY. INDICATIVE

CONSTRUCTION COST ESTIMATES ARE BASED ON PREVIOUS

SIMILAR TYPE WORKS.

4. THE FOLLOWING CRITICAL INFORMATION IS REQUIRED TO

VERIFY THE FEASIBILITY OF THE PROPOSED OPTION AND

DEVELOPED THIS FURTHER AT DETAILED DESIGN (IF

PREFERRED)

4.1. TOPOGRAPHICAL SURVEY - CONFIRM GEOMETRIC

PARAMETER AND SITE CONSTRAINTS

4.2. SITE INVESTIGATION INFORMATION - CONFIRM

FOUNDATION PARAMETERS

4.3. LIAISON WITH HIGHWAY ENGLAND - CONFIRM

STRUCTURAL REQUIREMENTS

4.4. LIAISON WITH STATUTORY UNDERTAKERS - CONFIRM

EXISTING/ NEW SERVICES IMPACTED BY THE WORKS.

5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

OTHERWISE.

6. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

7. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS OR

ERRORS SEEK DESIGNER CLARIFICATION.

8. FOR BOREHOLE INFORMATION REFER TO GROUND

INVESTIGATION REPORT

LIMITS OF LAND TO BE ACQUIRED OR USED

PERMANENTLY OR TEMPORARILY

PROPOSED LAYOUT- DESIGN FIX 3: REV 2

(16/08/2017)

LAND TO BE USED FOR CONSTRUCTION,

MAINTENANCE AND OPERATION

CURRENTLY OWNED BY SECRETARY OF

STATE

LAND TO BE PERMANENTLY ACQUIRED FOR

CONSTRUCTION, MAINTENANCE AND

OPERATION

THIRD PARTY LAND TEMPORARILY

REQUIRED DURING CONSTRUCTION

AREA NOT INCLUDED WITHIN THE DCO

BOUNDARY

KEY

IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS

DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS

RISK REFERENCE:

REF 001 - RISK ASSOCIATED WITH WORKING AT HEIGHT

REF 002 - WORKING ADJACENT TO LIVE TRAFFIC

REF 004 - WORKING ADJACENT TO SERVICES, DAMAGE TO EXISTING SERVICES, ELECTROCUTION

REF 011 - BRIDGE/WALL INTERFACE, DIFFERENTIAL SETTLEMENT

INDICATES A RESIDUAL RISK AS A WARNING

SAFETY, HEALTH AND ENVIRONMENTAL SYMBOL LEGEND

*CONTRACTOR SHALL BE RESPONSIBLE FOR THE

DESIGN OF RETAINING STRUCTURES LESS THAN 1.5m

RETAINED HEIGHT. THE STRUCTURE SHALL HAVE A

SMOOTH TRAFFIC FACE IN ACCORDANCE TO 19/06. THE

CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE

PROVISION OF A SMOOTH TRANSITION BETWEEN THE

RETAINING STRUCTURE ≤1.5m & ≥1.5m

AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
Page 78: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX D-4

RETAINING WALL 4 (RW4) GENERAL ARRANGEMENT

Page 79: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

VARIES

A1 NORTH BOUND VERGE

MIN

50

0

VA

RIE

S

TOP OF RE WALL

PROPOSED

SLIP ROAD

BOTTOM OF RE WALL (VARIES)

LEVELLING PAD

FACING PANELS

REINFORCING STRIPS

GROUND IMPROVEMENT REQUIRED

BENEATH THE PROPOSED RETAINING WALL

BACK FILL

SELECTED GRANULAR MATERIAL

PRECAST CAPPING UNIT

IN-SITU PARAPET SUPPORT SLAB

PROPRIETARY PARAPET SYSTEM

ACCORDING TO EN 1317

CONTAINMENT LEVEL N2 (TBC)

PROPRIETARY BARRIER SYSTEM

ACCORDING TO EN 1317

CONTAINMENT LEVEL N2 (TBC)

0+

780

0+

800

0+

820

0+

840

0+

860

0+

880

0+

900

0+

920

0+

940

0+

960

0+

980

0+

1000

0+

1020

0+

1040

0

+

1

0

6

0

0

+

1

0

8

0

0

+

1

1

0

0

0+

950

0+

970

0+

990

0+

1010

0+

1030

0

+

1

0

5

0

H

3

8

T

P

7

0

1

H50 B

H941T

H

5

0

B

H

9

3

8

H38 B

H803

H

3

8

B

H

6

0

1

18

.3

20

CH

. 0

+9

60

17

.7

11

CH

. 0

+9

40

13

.1

71

13

.3

67

13

.6

71

14

.0

81

BOTTOM OF WALL LEVELLING PAD

LEVEL

18

.8

97

CH

. 0

+9

80

14

.8

02

CH

. 1

+0

00

15

.7

70

CH

. 1

+0

20

16

.2

78

16

.7

78

CH

. 1

+0

40

16

.7

79

17

.7

80

CH

. 1

+0

60

17

.7

82

18

.7

84

PROPOSED SLIP ROAD LEVEL

13

.3

67

13

.1

71

13

.5

81

13

.5

81

13

.9

41

13

.9

41

14

.3

02

14

.3

02

14

.7

91

14

.7

91

15

.2

70

15

.2

70

15

.7

74

15

.7

74

16

.2

78

16

.2

78

17

.2

80

17

.2

80

17

.7

82

18

.0

16

18

.6

08

19

.1

35

19

.3

72

19

.5

74

19

.7

76

20

.0

01

20

.2

26

20

.4

35

20

.6

43

13

.8

76

14

.4

41

15

.2

86

16

.2

74

17

.2

89

18

.2

82

TOP OF RETAINING WALL LEVEL

CH

. 0

+9

50

CH

. 0

+9

70

CH

. 0

+9

80

CH

. 1

+0

10

CH

. 1

+0

30

CH

. 1

+0

50

REINFORCEMENT EARTH RETAINING WALL

TOP OF RETAINING WALL LEVEL

(m AOD)

BOTTOM OF WALL LEVELLING PAD LEVEL

(m AOD)

PROPOSED SLIP ROAD LEVEL

(m AOD)

CHAINAGE

(METRE)

PROPOSED CONTRACTOR DESIGN*

19

.5

80

20

.9

20

20

.5

77

21

.2

07

CH

. 1

+0

80

CH

. 1

+1

00

ELEVATION OF RETAINING WALL 4

SCALE 1:300

PLAN OF RETAINING WALL 4

SCALE 1:750

KINGSWAY VIADUCT UNDERBRIDGE ; STRUCTURE KEY 16271

RETAINING WALL - 4

SECTION A-A

SCALE 1:50

A

A

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

10/04/18 10/04/18

H. Mistry

10/04/18

H. Mistry

10/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 00012

RETAINING WALL 4

(STKEY 00004)

GENERAL ARRANGEMENT

P01 30/01/18 FOR INFORMATION AS MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

RETAINING WALL - 4 LOCATION

GENERAL NOTES

1. STRUCTURAL RETAINING WALL DETAILS PROVIDED ON THIS

DRAWING IS INDICATIVE ONLY BASED ON LIMITED

INFORMATION AVAILABLE TODAY.

2. THE SIZE OF STRUCTURAL ELEMENTS ARE BASED ON

PRELIMINARY CALCULATION AND PREVIOUS SIMILAR TYPE

WORKS. ALL INFORMATION IS SUBJECT TO DETAILED DESIGN

PRIOR TO FINAL CONFIRMATION.

3. DETAILS PROVIDED ARE FOR INFORMATION ONLY. INDICATIVE

CONSTRUCTION COST ESTIMATES ARE BASED ON PREVIOUS

SIMILAR TYPE WORKS.

4. THE FOLLOWING CRITICAL INFORMATION IS REQUIRED TO

VERIFY THE FEASIBILITY OF THE PROPOSED OPTION AND

DEVELOPED THIS FURTHER AT DETAILED DESIGN (IF

PREFERRED)

4.1. TOPOGRAPHICAL SURVEY - CONFIRM GEOMETRIC

PARAMETER AND SITE CONSTRAINTS

4.2. SITE INVESTIGATION INFORMATION - CONFIRM

FOUNDATION PARAMETERS

4.3. LIAISON WITH HIGHWAY ENGLAND - CONFIRM

STRUCTURAL REQUIREMENTS

4.4. LIAISON WITH STATUTORY UNDERTAKERS - CONFIRM

EXISTING/ NEW SERVICES IMPACTED BY THE WORKS.

5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

OTHERWISE.

6. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

7. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS OR

ERRORS SEEK DESIGNER CLARIFICATION.

8. FOR BOREHOLE INFORMATION REFER TO GROUND

INVESTIGATION REPORT

LIMITS OF LAND TO BE ACQUIRED OR USED

PERMANENTLY OR TEMPORARILY

PROPOSED LAYOUT- DESIGN FIX 3: REV 2

(16/08/2017)

LAND TO BE USED FOR CONSTRUCTION,

MAINTENANCE AND OPERATION

CURRENTLY OWNED BY SECRETARY OF

STATE

LAND TO BE PERMANENTLY ACQUIRED FOR

CONSTRUCTION, MAINTENANCE AND

OPERATION

THIRD PARTY LAND TEMPORARILY

REQUIRED DURING CONSTRUCTION

AREA NOT INCLUDED WITHIN THE DCO

BOUNDARY

KEY

*CONTRACTOR SHALL BE RESPONSIBLE FOR THE

DESIGN OF RETAINING STRUCTURES LESS THAN 1.5m

RETAINED HEIGHT. THE STRUCTURE SHALL HAVE A

SMOOTH TRAFFIC FACE IN ACCORDANCE TO 19/06. THE

CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR THE

PROVISION OF A SMOOTH TRANSITION BETWEEN THE

RETAINING STRUCTURE ≤1.5m & ≥1.5m

IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS

DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS

RISK REFERENCE:

REF 001 - RISK ASSOCIATED WITH WORKING AT HEIGHT

REF 002 - WORKING ADJACENT TO LIVE TRAFFIC

REF 004 - WORKING ADJACENT TO SERVICES, DAMAGE TO EXISTING SERVICES, ELECTROCUTION

REF 011 - BRIDGE/WALL INTERFACE, DIFFERENTIAL SETTLEMENT

INDICATES A RESIDUAL RISK AS A WARNING

SAFETY, HEALTH AND ENVIRONMENTAL SYMBOL LEGEND

AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
Page 80: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX D-5

RETAINING WALL 5 (RW5) GENERAL ARRANGEMENT

Page 81: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

0+

800

0+

820

0+

840

0+

860

0+

880

0+

900

0+

920

0+

940

0+

960

0+

980

1+

000

1+

020

1+

040

1

+

0

6

0

1

+

0

8

0

1

+

1

0

0

1

+

1

2

0

1

+

1

4

0

1

+

1

6

0

1

6

0

3

0

0

H

3

8

T

P

7

0

1

H

5

0

B

H

9

4

1

T

H

5

0

B

H

9

3

8

H

3

8

B

H

8

0

3

H38 BH602A

H

3

8

B

H

6

0

1

CAPPING

BEAM

TOP OF PILE

PROPRIETARY TUBULAR

HANDRAIL SYSTEM

1350

25

0

75

0

70

0

150

150

600-900Ø CONTIGUOUS

BORED PILES (TBC)

SLIP ROAD

BORED PILE

TOE OF CONTIGUOUS

PROPOSED DESIGNED

RETAINING HEIGHT LEVEL

PROPRIETARY BARRIER

SYSTEM ACCORDING TO

EN 1317 CONTAINMENT

LEVEL N2 (TBC)

= =

CONTIGUOUS BORED

PILES 600-900mm DIA.

(TBC)

17

.3

09

CH

. 0

+9

60

CHAINAGE

(METRE)

16

.6

31

CH

. 0

+9

40

1.7

15

1.7

15

0.7

12

PILE TOE LEVEL

CH

. 0

+9

80

0.7

12

1.4

36

19

.0

36

CH

. 1

+0

00

1.4

36

3.4

73

20

.0

58

CH

. 1

+0

20

3.4

73

6.2

61

20

.9

47

21

.7

14

CH

. 1

+0

60

9.2

25

21

.7

11

CH

. 1

+0

80

22

.5

38

CH

. 1

+1

00

TOP OF PROPOSED

PILE LEVEL

PROPOSED TOE

LEVEL (m AOD)

TOP OF RETAINING

STRUCTURE LEVEL

(m AOD)

13

.4

02

13

.8

27

14

.6

22

15

.7

35

16

.9

92

18

.2

56

19

.5

17

20

.7

74

22

.0

27

PROPOSED DESIGNED

RETAINING HEIGHT

LEVEL (m AOD)

PROPOSED DESIGNED

RETAINING HEIGHT

LEVEL

15

.8

81

16

.6

09

18

.3

36

19

.3

58

20

.2

47

21

.0

14

TOP OF PILE LEVEL

(m AOD)

18

.1

13

17

.4

19

CONTIGUOUS BORED PILES

600-900mm DIAMETER WITH

150mm CLEAR SPACING

9.2

25

6.2

61

CH

. 1

+0

40

CONTIGUOUS BORED PILED WALL PROPOSED CONTRACTOR DESIGN*

A1 SOUTH

BOUND

PLAN OF RETAINING WALL 5

SCALE 1:750

ELEVATION OF RETAINING WALL 5

SCALE 1:300

RETAINING WALL - 5 LOCATION

RETAINING WALL - 5

KINGSWAY VIADUCT UNDERBRIDGE ; STRUCTURE KEY 16271

A

A

TYPICAL DETAIL OF CONTIGUOUS BORED PILES

SCALE 1:25

SECTION A-A

SCALE 1:25

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R. Ayre M.Tziolas

10/04/18 10/04/18

H. Mistry

10/04/18

H. Mistry

10/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 00013

RETAINING WALL 5

(STKEY 00005)

GENERAL ARRANGEMENT

P01 30/01/18 FOR INFORMATION AS MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

GENERAL NOTES

1. STRUCTURAL RETAINING WALL DETAILS PROVIDED ON THIS

DRAWING IS INDICATIVE ONLY BASED ON LIMITED

INFORMATION AVAILABLE TODAY.

2. THE SIZE OF STRUCTURAL ELEMENTS ARE BASED ON

PRELIMINARY CALCULATION AND PREVIOUS SIMILAR TYPE

WORKS. ALL INFORMATION IS SUBJECT TO DETAILED DESIGN

PRIOR TO FINAL CONFIRMATION.

3. DETAILS PROVIDED ARE FOR INFORMATION ONLY. INDICATIVE

CONSTRUCTION COST ESTIMATES ARE BASED ON PREVIOUS

SIMILAR TYPE WORKS.

4. THE FOLLOWING CRITICAL INFORMATION IS REQUIRED TO

VERIFY THE FEASIBILITY OF THE PROPOSED OPTION AND

DEVELOPED THIS FURTHER AT DETAILED DESIGN (IF

PREFERRED)

4.1. TOPOGRAPHICAL SURVEY - CONFIRM GEOMETRIC

PARAMETER AND SITE CONSTRAINTS

4.2. SITE INVESTIGATION INFORMATION - CONFIRM

FOUNDATION PARAMETERS

4.3. LIAISON WITH HIGHWAY ENGLAND - CONFIRM

STRUCTURAL REQUIREMENTS

4.4. LIAISON WITH STATUTORY UNDERTAKERS - CONFIRM

EXISTING/ NEW SERVICES IMPACTED BY THE WORKS.

5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

OTHERWISE.

6. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

7. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS OR

ERRORS SEEK DESIGNER CLARIFICATION.

8. FOR BOREHOLE INFORMATION REFER TO GROUND

INVESTIGATION REPORT

LIMITS OF LAND TO BE ACQUIRED OR USED

PERMANENTLY OR TEMPORARILY

PROPOSED LAYOUT- DESIGN FIX 3: REV 2

(16/08/2017)

LAND TO BE USED FOR CONSTRUCTION,

MAINTENANCE AND OPERATION

CURRENTLY OWNED BY SECRETARY OF

STATE

LAND TO BE PERMANENTLY ACQUIRED FOR

CONSTRUCTION, MAINTENANCE AND

OPERATION

THIRD PARTY LAND TEMPORARILY

REQUIRED DURING CONSTRUCTION

AREA NOT INCLUDED WITHIN THE DCO

BOUNDARY

KEY

IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS

DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS

RISK REFERENCE:

REF 001 - RISK ASSOCIATED WITH WORKING AT HEIGHT

REF 002 - WORKING ADJACENT TO LIVE TRAFFIC

REF 003 - IN-SITU RC WORKS

REF 005 –WORKING ADJACENT TO SERVICES. DAMAGE TO EXISTING SERVICES, ELECTROCUTION

REF 013 - LIFTING/ INSTALLATION LARGE REINFORCEMENT CAGES

REF 014 - HAVS DUE TO EXCESS PILE CUTTING/ TRIMMING

INDICATES A RESIDUAL RISK AS A WARNING

SAFETY, HEALTH AND ENVIRONMENTAL SYMBOL LEGEND

*CONTRACTOR SHALL BE RESPONSIBLE FOR THE

DESIGN OF RETAINING STRUCTURES LESS THAN 1.5m

RETAINED HEIGHT. THE STRUCTURE SHALL HAVE A

SMOOTH TRAFFIC FACE IN ACCORDANCE WITH 19/06.

THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR

THE PROVISION OF A SMOOTH TRANSITION BETWEEN

THE RETAINING STRUCTURE ≤1.5m & ≥1.5m

S

L

IP

R

O

A

D

AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Abutment
AutoCAD SHX Text
Bridge
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
AutoCAD SHX Text
Parapet
Page 82: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX D-6

RETAINING WALL 6 (RW6) GENERAL ARRANGEMENT

Page 83: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

93

.6

70

PROPOSED TOP OF RETAINING

HEIGHT LEVEL (m AOD)

CHAINAGE

(METRE)

CH

. 4

+1

20

PROPOSED BOTTOM OF RETAINING

HEIGHT LEVEL (m AOD)

94

.3

39

CH

. 4

+1

40

93

.5

82

95

.5

71

CH

. 4

+1

60

94

.2

12

97

.2

67

CH

. 4

+1

80

94

.7

74

97

.4

48

CH

. 4

+2

00

95

.3

54

98

.0

74

CH

. 4

+2

20

95

.9

76

97

.9

51

CH

. 4

+2

40

96

.6

51

98

.3

31

CH

. 4

+2

60

97

.1

08

99

.2

77

CH

. 4

+2

80

97

.6

78

10

0.2

65

CH

. 4

+3

00

98

.3

75

10

1.2

06

CH

. 4

+3

20

98

.7

00

10

1.9

66

CH

. 4

+3

40

99

.5

95

10

2.8

05

CH

. 4

+3

60

10

0.7

26

10

3.7

74

CH

. 4

+3

80

10

2.1

16

10

4.9

49

CH

. 4

+4

00

10

3.7

35

92

.9

63

PROPOSED KING POST TOE LEVEL

(m AOD)

88

.5

15

84

.3

23

86

.5

75

86

.5

75

91

.2

01

91

.2

01

90

.9

75

98

.4

52

88

.1

94

89

.6

55

89

.6

55

92

.0

10

95

.1

65

88

.5

15

84

.3

23

84

.3

23

84

.3

23

87

.1

81

87

.1

81

90

.9

75

90

.4

52

88

.1

94

89

.6

55

89

.6

55

92

.0

10

95

.1

65

PROPOSED

CONTRACTOR DESIGN

PROPOSED KING POST RETAINING WALL

4+

080

4+

100

4+

120

4+

140

4+

160

4+

180

4+

200

4+

220

4+

240

4+

260

4+

280

4+

300

4+

320

4+

340

4+

360

4+

380

4+

400

4+

420

4+

440

H12 TP929

H12 TP928

H12 BH922

H12 TP932

H12 BH925H12 BH1001

H12 BH1002

H12 TP1001

H42 BH1

PRECAST CONCRETE PLANKS

SECTION UC KING-POST

A1 SLIP ROAD/A1 SOUTH BOUND

BOTTOM OF PILE

BORED PILE (T.B.C.)

PROPRIETARY SAFETY

BARRIER SYSTEM

ACCORDING TO EN 1317.

CONTAINMENT LEVEL N1

(TBC).

PROPRIETARY BARRIER SYSTEM

ACCORDING TO EN 1317

CONTAINMENT LEVEL N2 (TBC)

BORED PILE (T.B.C.)

SECTION UC KING-POST

SECTION UC KING POST

PRECAST CONCRETE PLANKS

RETAINING WALL 6

REFER TO ELEVATION OF

FOR TOE LEVEL INFORMATION

ELEVATION OF RETAINING WALL 6

SCALE 1:500

PLAN OF RETAINING WALL 6

SCALE 1:750

Date

DrawnScale

Drawing Title

Project Title

Date Date Date

Checked Approved Authorised

Client

Original Size

Drawing Number

Revision

Project Originator Volume

Location Type Role Number

Project Ref. No.

Rev. Date

Description By

Chk'd

App'd

uuuuuyuuyuyuyuy

Drawing Status Suitability

DO

N

OT

S

CA

LE

Millim

etres

100

10

0

© Crown Copyright and Database Rights 2015 Ordnance Survey 100018928

wsp.com

Three White Rose Office Park, Millshaw Park Lane, Leeds, LS11 0DL, UK

T+ 44 (0) 113 395 6200, F+ 44 (0) 113 395 6201

R.Ayre M.Tziolas

10/04/18 10/04/18

H. Mistry

10/04/18

H. Mistry

10/04/18

P02

AS SHOWN

HE551462 WSP SBR

BR008 DR S 00014

RETAINING WALL 6

(STKEY 00006)

GENERAL ARRANGEMENT

P01 30/01/18 FOR INFORMATION AS MT HM

P02 10/04/18 AREAS BELOW 1.5m CONTRACTOR DESIGN RA MT HM

A1

A1 BIRTLEY TO COALHOUSE

FOR INFORMATION S1

TYPICAL CROSS SECTION

SCALE 1:50

RETAINING WALL - 6

TYPICAL ELEVATION OF KING POST

RETAINING WALL

SCALE 1:25

RETAINING WALL - 6 LOCATION

GENERAL NOTES

1. STRUCTURAL RETAINING WALL DETAILS PROVIDED ON THIS

DRAWING IS INDICATIVE ONLY BASED ON LIMITED

INFORMATION AVAILABLE TODAY.

2. THE SIZE OF STRUCTURAL ELEMENTS ARE BASED ON

PRELIMINARY CALCULATION AND PREVIOUS SIMILAR TYPE

WORKS. ALL INFORMATION IS SUBJECT TO DETAILED DESIGN

PRIOR TO FINAL CONFIRMATION.

3. DETAILS PROVIDED ARE FOR INFORMATION ONLY. INDICATIVE

CONSTRUCTION COST ESTIMATES ARE BASED ON PREVIOUS

SIMILAR TYPE WORKS.

4. THE FOLLOWING CRITICAL INFORMATION IS REQUIRED TO

VERIFY THE FEASIBILITY OF THE PROPOSED OPTION AND

DEVELOPED THIS FURTHER AT DETAILED DESIGN (IF

PREFERRED)

4.1. TOPOGRAPHICAL SURVEY - CONFIRM GEOMETRIC

PARAMETER AND SITE CONSTRAINTS

4.2. SITE INVESTIGATION INFORMATION - CONFIRM

FOUNDATION PARAMETERS

4.3. LIAISON WITH HIGHWAY ENGLAND - CONFIRM

STRUCTURAL REQUIREMENTS

4.4. LIAISON WITH STATUTORY UNDERTAKERS - CONFIRM

EXISTING/ NEW SERVICES IMPACTED BY THE WORKS.

5. ALL DIMENSIONS ARE IN MILLIMETERS UNLESS NOTED

OTHERWISE.

6. ALL LEVELS ARE IN METERS UNLESS NOTED OTHERWISE.

7. DO NOT SCALE IN CASE OF ANY DOUBTS, OMISSIONS OR

ERRORS SEEK DESIGNER CLARIFICATION.

8. FOR BOREHOLE INFORMATION REFER TO GROUND

INVESTIGATION REPORT

LIMITS OF LAND TO BE ACQUIRED OR USED

PERMANENTLY OR TEMPORARILY

PROPOSED LAYOUT- DESIGN FIX 3: REV 2

(16/08/2017)

LAND TO BE USED FOR CONSTRUCTION,

MAINTENANCE AND OPERATION

CURRENTLY OWNED BY SECRETARY OF

STATE

LAND TO BE PERMANENTLY ACQUIRED FOR

CONSTRUCTION, MAINTENANCE AND

OPERATION

THIRD PARTY LAND TEMPORARILY

REQUIRED DURING CONSTRUCTION

AREA NOT INCLUDED WITHIN THE DCO

BOUNDARY

KEY

IN ADDITION TO THE HAZARDS/RISKS NORMALLY ASSOCIATED WITH THE TYPES OF WORK DETAILED ON THIS

DRAWING, NOTE THE FOLLOWING SIGNIFICANT RESIDUAL RISKS

RISK REFERENCE:

REF 001 - OPEN PILE HOLES

REF 002 - LIFTING OF LONG STEEL SECTIONS AND HEAVY PRECAST CONCRETE PANELS

REF 003 - POOR MATERIAL PROPERTIES

REF 004 - EXISTING EARTHWORKS INSTABILITY

REF 005 - EXISTENCE OF COAL MINES

REF 006 - CONTAINMENT LAND

REF 007 - HIGH GROUND WATER LEVEL

REF 008 - BEDROCK HIGHER THAN ANTICIPATED LEVEL

REF 009 - BEDROCK LOWER THAN ANTICIPATED LEVEL

INDICATES A RESIDUAL RISK AS A WARNING

SAFETY, HEALTH AND ENVIRONMENTAL SYMBOL LEGEND

*CONTRACTOR SHALL BE RESPONSIBLE FOR THE

DESIGN OF RETAINING STRUCTURES LESS THAN 1.5m

RETAINED HEIGHT. THE STRUCTURE SHALL HAVE A

SMOOTH TRAFFIC FACE IN ACCORDANCE WITH 19/06.

THE CONTRACTOR SHALL ALSO BE RESPONSIBLE FOR

THE PROVISION OF A SMOOTH TRANSITION BETWEEN

THE RETAINING STRUCTURE ≤1.5m & ≥1.5m

CONTRACTOR DESIGN ELEMENT

Page 84: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Appendix E

DESIGN RISK ASSESSMENTS

Page 85: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX E-1

RW1 DESIGNERS RISK ASSESSMENT

Page 86: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where appropriate, e.g.. location/environment,

construction, operation, maintenance, alteration/demolition)

Work Element/Location(where appropriate)

Hazard or Risk Issue Identified Risk Management Owner

Design ERIC Action Required (e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or Requirements

Design Action Status/Final Resolution Notes(e.g.. traceability of ERIC action, communication of significant residual risk, critical design criteria, etc.)

Significant Residual Risk§

(Y/N)

Date Logged/Reviewed

Raised By

011 Construction Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

Working with reinforced concrete walls require handling of large volumes of concrete including placing at height of shutters for the walls.Shuttering requires significant temporary works.Also large reinforcement cages introduces risks associated with impaling/ heavy lifting of bars, working at heights etc.

Designer Use of alternative methods (precast units) as abutment walls and foundation reduces in-situ concrete works for the substructure elements.Rebar cages potentially fabricated in controlled works area then lifted into final position which reduces risks.

Design minimises the need for temporary works Specific construction methods to be defined on drawing and specification.

N 06/02/2018 Michail Tziolas

012 Construction Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

Temporary works to support deep excavations for reinforced concrete wall. Restricted working area to install temp works increases risk of personnel entrapment/injury.

Designer The use of alternative construction method (pilling) as retaining walls eliminates the need for temporary works to support deep excavations. Although the existing ground profile favours bottom up method (L-shape wall) in comparison to top down method (sheet piles).Permanent works take the place of temporary works.'Top-down' construction eliminates deep unsupported excavations that require temp support although with the existing ground profile this construction method is not feasible.

Contractor to consider any temporary safe guarding measures required at the top of the wall to limit falls from height (installation of parapet).

Appropriate reference on drawing N 06/02/2018 Michail Tziolas

013 Construction Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

Transport of large components - potential risks associated with the movement of large abnormal loads.

Contractor Detailed design to ensure the sections of walls (precast L- shape walls) are manageable (not excessively long etc.) to ensure they can be delivered to site with minimal potential logistical risks. precast panels with both dimensions (span and height) greater than 3m cannot easily be delivered to site and a in-situ solution should be used instead.

Contractor to provide assembly area as part of site compound.

By ensuring the length of retaining wall sections are not excessively large, would reduce risk associated with transport and assembly on site.

N 06/02/2018 Michail Tziolas

014 Construction Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

Lifting and installation of heavy precast reinforced L-shape retaining walls, risk associated with the lifting operations and installation of the structural elements.

Contractor The pre-cast walls are to be specified such that they can be pre-prepared off site and brought to site as required. Risk to be mitigated by minimising weight of units where posssible. Appropriate lifting points to be included at detailed design stage aiming to give best stability during lifting condition. Lifting points to be shared with contractor's lift planners at an early stage for review of appropriateness to allow changes to be made as early in the process as possible.

Appropriate cranage to be used with a lifting plan to off load and install prec-cast walls.

Risks associated with the lifting/installation of pre-cast walls to be added to drawings. Lifting point information to be shared with contractor. Contractor to implement safe system. Ensure sufficient working space to locate plant and equipment.

Y 06/02/2018 Michail Tziolas

015 Construction/Maintenance Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

Poorer than anticipated engineering properties of the founding strata and material below the retaining wall resulting in movement of the structure beyond its serviceability limits.

Designer Ground improvement works may be required below the footprint of the retaining wall to ensure the settlement that occurs is within tolerable limits.

An intrusive ground investigation to be undertaken to assess the ground conditions. Groundwater monitoring to be undertaken as part of the investigation. Based of the conclusions from the intrusive ground investigation confirmation of ground improvement works is to be provided.

Ground Investigation Report to be provided. Preliminary design to take account of anticipated settlements and the potential requirement for ground improvement.

Y 21/03/2018 Ruth Jacobs

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 1

Guidance notes (see guidance notes page for more details)Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

22/03/2018 Page 1 of 2

Page 87: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where appropriate, e.g.. location/environment,

construction, operation, maintenance, alteration/demolition)

Work Element/Location(where appropriate)

Hazard or Risk Issue Identified Risk Management Owner

Design ERIC Action Required (e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or Requirements

Design Action Status/Final Resolution Notes(e.g.. traceability of ERIC action, communication of significant residual risk, critical design criteria, etc.)

Significant Residual Risk§

(Y/N)

Date Logged/Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 1

Guidance notes (see guidance notes page for more details)Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

016 Construction Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

The proposed works may undermine / cause instability within the existing earthworks.

Designer Additional temporary works my be required to prevent instability of existing embankment occurring during construction.

A review of HA GDMS and the Principal Earthwork Inspection records held there. Intrusive investigation undertaken to determine the composition of the existing earthworks.

Temporary works designer to take into account the presence of the existing earthworks.

Y 21/03/2018 Ruth Jacobs

017 Construction/Maintenance Retaining Wall 1 - Option E (Reinforced Concrete L-Shape Retaining Wall)

The retaining wall may be adversely impacted by the collapse of coal mine working below the retaining wall foundations.

Designer Grouting of the worked coal seams below the retaining wall, or a basal geogrid to reduce the impact of migrating crown holes on the retaining wall, may be required.

An intrusive ground investigation and coal mining risk assessment to be undertaken to determine the requirement for grouting.

Ground Investigation Report and Coal Mining Risk Assessment reporting to be produced and confirm the need for stabilisation works below the retaining wall foundations.

Y 21/03/2018 Ruth Jacobs

22/03/2018 Page 2 of 2

Page 88: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX E-2 RW2 DESIGNERS RISK ASSESSMENT

Page 89: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where appropriate, e.g.. location/environment,

construction, operation, maintenance, alteration/demolition)

Work Element/Location(where appropriate)

Hazard or Risk Issue Identified Risk Management Owner Design ERIC Action Required (e.g.. hazard elimination/risk mitigation action, information to

be provided to others)Significant Temporary Works

Requirements/Management Arrangements and/orany Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes(e.g.. traceability of ERIC action, communication of significant residual risk, critical design criteria, etc.)

Significant Residual Risk§

(Y/N)Date Logged/

ReviewedRaised By

001 Construction Retaining Wall 2 - Option A (Sheet Pile Retaining Wall)

Produce high levels of noise during machine and sheet pilling driving machine operation.

Contractor Noise monitoring devices which alert people to a rise in noise level. PPE/ noise protectors to protect people's hearing, preferable to be used for short periods only for specific tasks in noisy spaces. Use of nuisance management strategy.

Reduction in noise generated to a safe level of separation of people from excessive level of noise.

The level of risk from residual noise may be reduced by applying appropriate control.

N 06/02/2018 Michail Tziolas

002 Construction Retaining Wall 2 - Option A (Sheet Pile Retaining Wall)

Handling of heavy steel sheet pile sections. Contractor Specify method of handling that reduces the risk of manual handling.

Contractor to adopt safe method of handling. No action. N 06/02/2018 Michail Tziolas

003 Maintenance/Operation Retaining Wall 2 - Option A (Sheet Pile Retaining Wall)

Errant vehicles/maintenance personnel falling behind retainng wall from the A1 road level.

Operator It is proposed that either a VRS be fixed along the top of the retaining walls. To limit the risk of falls from height

- No action. N 06/02/2018 Michail Tziolas

004 Construction / Maintenance Retaining wall 2 Poorer than anticipated engineering properties of the material behind and / or in front of the retaining wall resulting in deflections of the structure beyond its serviceability limits.

Designer Design to take into account the results of the ground investigation, once completed, and sensitivity analysis conducted where uncertainty exists.

An intrusive ground investigation to be undertaken to assess the ground conditions. Based of the conclusions from the intrusive ground investigation suitable design shall be undertaken.

Ground Investigation Report to be provided. Preliminary design to take account of anticipated ground conditions.

Yes 09/04/2018 Ruth Jacobs

005 Construction Retaining wall 2 The proposed works may undermine / cause instability within the existing earthworks.

Designer Additional temporary works my be required to prevent instability of the existing embankment occurring during construction of the retaining wall.

A review of HA GDMS and the Principal Earthwork Inspection records held there. Intrusive investigation undertaken to determine the composition of the existing earthworks.

Temporary works designer to take into account the presence of the existing earthworks.

Yes 09/04/2018 Ruth Jacobs

006 Construction / Maintenance Retaining wall 2 Potential for coal mine workings to cause collapse/increased deflection of the retaining wall.

Designer Grouting of the worked coal seams below the retaining wall may be required.

An intrusive ground investigation and coal mining risk assessment to be undertaken to determine the requirement for grouting.

Ground Investigation Report and Coal Mining Risk Assessment reporting to be produced and confirm the need for stabilisation works below the length of the retaining wall structure.

Yes 09/04/2018 Ruth Jacobs

007 Construction Retaining wall 2 Contaminated land or materials on site Contractor Assumed good practice will be carried out in site to prevent material becoming contaminated. Unusual smells to be notified to the supervising Engineer for assessment before work continues. Spillage to be dealt with promptly by identified methods. Appropriate PPE and induction.

An intrusive ground investigation to be undertaken to assess the ground conditions, including undertaking geo-environmental testing.

The geo-environmental conditions anticipated to be encountered on site shall be highlighted within the Ground Investigation Report and subsequent design report.

Yes 09/04/2018 Ruth Jacobs

008 Construction Retaining wall 2 High groundwater levels (including perched groundwater) causing excessive unfavourable actions on retaining structure, leading to greater than anticipated deflection of the embedded wall.

Designer Design to take into account the results of the ground investigation, once completed, and sensitivity analysis conducted where uncertainty exists.

An intrusive ground investigation to be undertaken to assess the ground conditions. Groundwater monitoring to be undertaken as part of the investigation. Based of the conclusions from the intrusive ground investigation suitable design shall be undertaken.

Ground Investigation Report to be provided. Preliminary design to take account of anticipated groundwater conditions.

Yes 09/04/2018 Ruth Jacobs

Issue 1.0Copy rows then insert above this line to ensure formula are copied

Way of Working: Project DeliveryT446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 2

Guidance notes (see guidance notes page for more details)Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

09/04/2018 Page 1 of 1

Page 90: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX E-3 RW3 DESIGNERS RISK ASSESSMENT

Page 91: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

001 Construction Retaining Wall 3&4 -

reinforced earth wall

Risk associated with working at height Designer Design to consider method of construction that reduces the

risk of working at height.

Pre-fabricated sections proposed to avoid in-situ

construction at height.

Temporary work minimised by use of precast

materials.

Precast requirements to be defined in the works

information.

N 03/04/2018 Michail Tziolas

002 Construction Retaining Wall 3&4 -

reinforced earth wall

Working adjacent to live traffic Designer Construction methods with limited working room required

and interface with live traffic

TM required to be installed by a competent

contractor

Appropriate reference on drawing Y 03/04/2018 Michail Tziolas

003 Construction Retaining Wall 3&4 -

reinforced earth wall

Live road (A1 main line and slip roads) at risk of

falling debris during lifting operation of structural

elements.

Contractor Extra attention to prevent debris falling to A1 carriageway

and slip road during lifting operations.

TM to be in place during works with the crane.

Contractor to ensure TM details to be approved

prior to undertaking site based operations.

Note on drawings to be provided highlighting the

need for road closures or traffic management during

lifting operations.

Y 03/04/2018 Rakesh Mehta

004 Construction Retaining Wall 3&4 -

reinforced earth wall

Working adjacent to services. Damage to existing

services, electrocution.

Contractor Statutory undertakers information indicate that services

are located within the vicinity of retaining walls and may

potentially be affected by the works.

Statutory undertakers searches/consultation to be

undertaken prior to detailed design (on-going). This is to

enable requirements for diversion/protection to be

determined. This should be reviewed by contractor prior to

undertaking works.

At this stage it is assumed that all services found

affecting the proposed retaining wall works shall

be diverted/ protected accordingly to progress the

retaining wall works on site. During construction,

areas to be scanned by trained and competent

contractor to confirm no presence of services

prior to works. Contractor to locate any services

present using hand tools before mechanical

excavation can commence. Contractor to also

liaise with the statutory undertakers/local

authorities and the HE maintenance service

providers to locate all services prior to piling or

excavation works. Contractor to implement safe

system. All excavation to be examined prior to

use.

Appropriate note/reference to be put on drawings

relating to service location at detailed design.

Y 03/04/2018 Michail Tziolas

005 Construction Retaining Wall 3&4 -

reinforced earth wall

Transport of large components - potential risks

associated with the movement of large abnormal

loads.

Contractor Detailed design to ensure the sections of walls (reinforcing

strips, etc..) are manageable (not excessively long etc.) to

ensure they can be delivered to site with minimal potential

logistical risks.

Contractor to provide assembly area as part of site

compound.

By ensuring the length of retaining wall sections are

not excessively large, would reduce risk associated

with transport and assembly on site.

N 03/04/2018 Michail Tziolas

006 Construction Retaining Wall 3&4 -

reinforced earth wall

Site vehicles using public highways to transport

excess materials to disposal sites. Mud on roads,

airborne contamination during/after transit

Contractor Identify agreed route where disruption will be minimised

and how the works areas will be accessed by construction

traffic during the works.

Wheel washing facility to be used on site to

minimise mud tracked onto road network.

Tarpaulins and straps to be checked before

deliveries leave site. Haulage of material to be

considered, in particular how to avoid/limit

disruption to the traffic during construction.

Contractor to plan all site deliveries and make

suppliers aware of these. To be defined in TTM plan.

N 03/04/2018 Michail Tziolas

007 Construction Retaining Wall 3&4 -

reinforced earth wall

Delivery material/structural components on site

cause obstruction lead to accidents (collision etc.)

Contractor Contractor to consider suitable holding areas on site in close

proximity to the works.

Contractor to provide a suitable holding area as

part of the site compound.

No further action N 03/04/2018 Michail Tziolas

008 Maintenance Retaining Wall 3&4 -

reinforced earth wall

Struck by traffic during inspection works. Operator Safe methods of work should be determined for all required

maintenance. Traffic management arrangements to be

determined before any work commences. The H&S

maintenance file should be consulted whilst planning the

required work.

TM to be deployed when undertaking

inspection/maintenance type works. Details to be

provided in TTM plans.

SSOW to be deployed during

inspection/maintenance

N 03/04/2018 Michail Tziolas

009 Maintenance Retaining Wall 3&4 -

reinforced earth wall

Errant slip road vehicles/maintenance personnel

falling into the A1 or the slip roads from the raised

road levels.

Operator It is proposed that either a VRS be fixed along the top of the

retaining walls. Alternatively a safety barrier will be fixed

adjacent to the slip road edge (provide vehicle containment)

and a pedestrian parapet be provided along the top or

adjacent of the retaining wall (prevent falls from height).

Contractor to determine TM requirements for the

installation of parapets. Details to be documented

in TTM plans.

Add note on drawing to identify risk. N 03/04/2018 Michail Tziolas

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 3 and 4

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

11/04/2018 Page 1 of 2

Page 92: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 3 and 4

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

010 Operation Retaining Wall 3&4 -

reinforced earth wall

Injury to driver upon impact with the retaining wall

face.

Operator Proposed retaining wall to be provided with a smooth finish

(in some cases cladding) and a VRS in front according to

TD19/06 - this reduces the severity of injury upon vehicular

impact.

Contractor to consider temporary works required

to fix cladding.

Appropriate reference on drawing N 03/04/2018 Michail Tziolas

011 Construction Retaining Wall 3&4 -

reinforced earth wall

Transition between reinforced earth embankment

and bridge abutment. Greater than tolerable

differential settlements.

Designer Bridge designer and Specialist Reinforced Soil Designer to

work closely to ensure interaction is acceptable. Contractor

to confirm appointments of specialist RS Wall designer at

the earliest opportunity so they can engage with the WSP

bridge design team

None None Y 06/02/2018 Michail Tziolas

012 Construction / Maintenance Retaining Wall 3&4 -

reinforced earth wall

Poorer than anticipated engineering properties of

the founding strata and material below the retaining

wall resulting in movement of the structure beyond

its serviceability limits.

Designer Ground improvement works may be required below the

footprint of the retaining wall to ensure the settlement that

occurs is within tolerable limits.

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Groundwater monitoring to be undertaken as part

of the investigation. Based of the conclusions

from the intrusive ground investigation

confirmation of ground improvement works is to

be provided.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

settlements and the potential requirement for

ground improvement.

Y 22/03/2018 Ruth Jacobs

013 Construction Retaining Wall 3&4 -

reinforced earth wall

The proposed works may undermine / cause

instability within the existing earthworks.

Designer Additional temporary works my be required to prevent

instability of existing embankment occurring during

construction.

A review of HA GDMS and the Principal Earthwork

Inspection records held there. Intrusive

investigation undertaken to determine the

composition of the existing earthworks.

Temporary works designer to take into account the

presence of the existing earthworks.

Y 22/03/2018 Ruth Jacobs

014 Construction / Maintenance Retaining Wall 3&4 -

reinforced earth wall

The retaining wall may be adversely impacted by the

collapse of coal mine working below the retaining

wall foundations.

Designer Grouting of the worked coal seams below the retaining wall,

or a basal geogrid to reduce the impact of migrating crown

holes on the retaining wall, may be required.

An intrusive ground investigation and coal mining

risk assessment to be undertaken to determine

the requirement for grouting.

Ground Investigation Report and Coal Mining Risk

Assessment reporting to be produced and confirm

the need for stabilisation works below the retaining

wall foundations.

Y 22/03/2018 Ruth Jacobs

Issue 1.0Copy rows then insert above this line to ensure formula are copied

11/04/2018 Page 2 of 2

Page 93: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX E-4

RW 4 DESIGNERS RISK ASSESSMENT

Page 94: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

001 Construction Retaining Wall 3&4 -

reinforced earth wall

Risk associated with working at height Designer Design to consider method of construction that reduces the

risk of working at height.

Pre-fabricated sections proposed to avoid in-situ

construction at height.

Temporary work minimised by use of precast

materials.

Precast requirements to be defined in the works

information.

N 03/04/2018 Michail Tziolas

002 Construction Retaining Wall 3&4 -

reinforced earth wall

Working adjacent to live traffic Designer Construction methods with limited working room required

and interface with live traffic

TM required to be installed by a competent

contractor

Appropriate reference on drawing Y 03/04/2018 Michail Tziolas

003 Construction Retaining Wall 3&4 -

reinforced earth wall

Live road (A1 main line and slip roads) at risk of

falling debris during lifting operation of structural

elements.

Contractor Extra attention to prevent debris falling to A1 carriageway

and slip road during lifting operations.

TM to be in place during works with the crane.

Contractor to ensure TM details to be approved

prior to undertaking site based operations.

Note on drawings to be provided highlighting the

need for road closures or traffic management during

lifting operations.

Y 03/04/2018 Rakesh Mehta

004 Construction Retaining Wall 3&4 -

reinforced earth wall

Working adjacent to services. Damage to existing

services, electrocution.

Contractor Statutory undertakers information indicate that services

are located within the vicinity of retaining walls and may

potentially be affected by the works.

Statutory undertakers searches/consultation to be

undertaken prior to detailed design (on-going). This is to

enable requirements for diversion/protection to be

determined. This should be reviewed by contractor prior to

undertaking works.

At this stage it is assumed that all services found

affecting the proposed retaining wall works shall

be diverted/ protected accordingly to progress the

retaining wall works on site. During construction,

areas to be scanned by trained and competent

contractor to confirm no presence of services

prior to works. Contractor to locate any services

present using hand tools before mechanical

excavation can commence. Contractor to also

liaise with the statutory undertakers/local

authorities and the HE maintenance service

providers to locate all services prior to piling or

excavation works. Contractor to implement safe

system. All excavation to be examined prior to

use.

Appropriate note/reference to be put on drawings

relating to service location at detailed design.

Y 03/04/2018 Michail Tziolas

005 Construction Retaining Wall 3&4 -

reinforced earth wall

Transport of large components - potential risks

associated with the movement of large abnormal

loads.

Contractor Detailed design to ensure the sections of walls (reinforcing

strips, etc..) are manageable (not excessively long etc.) to

ensure they can be delivered to site with minimal potential

logistical risks.

Contractor to provide assembly area as part of site

compound.

By ensuring the length of retaining wall sections are

not excessively large, would reduce risk associated

with transport and assembly on site.

N 03/04/2018 Michail Tziolas

006 Construction Retaining Wall 3&4 -

reinforced earth wall

Site vehicles using public highways to transport

excess materials to disposal sites. Mud on roads,

airborne contamination during/after transit

Contractor Identify agreed route where disruption will be minimised

and how the works areas will be accessed by construction

traffic during the works.

Wheel washing facility to be used on site to

minimise mud tracked onto road network.

Tarpaulins and straps to be checked before

deliveries leave site. Haulage of material to be

considered, in particular how to avoid/limit

disruption to the traffic during construction.

Contractor to plan all site deliveries and make

suppliers aware of these. To be defined in TTM plan.

N 03/04/2018 Michail Tziolas

007 Construction Retaining Wall 3&4 -

reinforced earth wall

Delivery material/structural components on site

cause obstruction lead to accidents (collision etc.)

Contractor Contractor to consider suitable holding areas on site in close

proximity to the works.

Contractor to provide a suitable holding area as

part of the site compound.

No further action N 03/04/2018 Michail Tziolas

008 Maintenance Retaining Wall 3&4 -

reinforced earth wall

Struck by traffic during inspection works. Operator Safe methods of work should be determined for all required

maintenance. Traffic management arrangements to be

determined before any work commences. The H&S

maintenance file should be consulted whilst planning the

required work.

TM to be deployed when undertaking

inspection/maintenance type works. Details to be

provided in TTM plans.

SSOW to be deployed during

inspection/maintenance

N 03/04/2018 Michail Tziolas

009 Maintenance Retaining Wall 3&4 -

reinforced earth wall

Errant slip road vehicles/maintenance personnel

falling into the A1 or the slip roads from the raised

road levels.

Operator It is proposed that either a VRS be fixed along the top of the

retaining walls. Alternatively a safety barrier will be fixed

adjacent to the slip road edge (provide vehicle containment)

and a pedestrian parapet be provided along the top or

adjacent of the retaining wall (prevent falls from height).

Contractor to determine TM requirements for the

installation of parapets. Details to be documented

in TTM plans.

Add note on drawing to identify risk. N 03/04/2018 Michail Tziolas

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 3 and 4

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

11/04/2018 Page 1 of 2

Page 95: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 3 and 4

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

010 Operation Retaining Wall 3&4 -

reinforced earth wall

Injury to driver upon impact with the retaining wall

face.

Operator Proposed retaining wall to be provided with a smooth finish

(in some cases cladding) and a VRS in front according to

TD19/06 - this reduces the severity of injury upon vehicular

impact.

Contractor to consider temporary works required

to fix cladding.

Appropriate reference on drawing N 03/04/2018 Michail Tziolas

011 Construction Retaining Wall 3&4 -

reinforced earth wall

Transition between reinforced earth embankment

and bridge abutment. Greater than tolerable

differential settlements.

Designer Bridge designer and Specialist Reinforced Soil Designer to

work closely to ensure interaction is acceptable. Contractor

to confirm appointments of specialist RS Wall designer at

the earliest opportunity so they can engage with the WSP

bridge design team

None None Y 06/02/2018 Michail Tziolas

012 Construction / Maintenance Retaining Wall 3&4 -

reinforced earth wall

Poorer than anticipated engineering properties of

the founding strata and material below the retaining

wall resulting in movement of the structure beyond

its serviceability limits.

Designer Ground improvement works may be required below the

footprint of the retaining wall to ensure the settlement that

occurs is within tolerable limits.

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Groundwater monitoring to be undertaken as part

of the investigation. Based of the conclusions

from the intrusive ground investigation

confirmation of ground improvement works is to

be provided.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

settlements and the potential requirement for

ground improvement.

Y 22/03/2018 Ruth Jacobs

013 Construction Retaining Wall 3&4 -

reinforced earth wall

The proposed works may undermine / cause

instability within the existing earthworks.

Designer Additional temporary works my be required to prevent

instability of existing embankment occurring during

construction.

A review of HA GDMS and the Principal Earthwork

Inspection records held there. Intrusive

investigation undertaken to determine the

composition of the existing earthworks.

Temporary works designer to take into account the

presence of the existing earthworks.

Y 22/03/2018 Ruth Jacobs

014 Construction / Maintenance Retaining Wall 3&4 -

reinforced earth wall

The retaining wall may be adversely impacted by the

collapse of coal mine working below the retaining

wall foundations.

Designer Grouting of the worked coal seams below the retaining wall,

or a basal geogrid to reduce the impact of migrating crown

holes on the retaining wall, may be required.

An intrusive ground investigation and coal mining

risk assessment to be undertaken to determine

the requirement for grouting.

Ground Investigation Report and Coal Mining Risk

Assessment reporting to be produced and confirm

the need for stabilisation works below the retaining

wall foundations.

Y 22/03/2018 Ruth Jacobs

Issue 1.0Copy rows then insert above this line to ensure formula are copied

11/04/2018 Page 2 of 2

Page 96: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX E-5

RW5 DESIGNERS RISK ASSESSMENT

Page 97: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

001 Construction Retaining Wall 5 -

contiguous bored piles wall

Risk associated with working at height Designer Design to consider method of construction that reduces the

risk of working at height.

Temporary work minimised by use of top down

construction techniques.

Top down method of construction is proposed to

reduce working at height when necessary. Top down

construction to be defined on the drawings.

Y 06/02/2018 Michail Tziolas

002 Construction Retaining Wall 5 -

contiguous bored piles wall

Working adjacent to live traffic Designer Construction methods with limited working room required

and interface with live traffic.

TM required to be installed by a competent

contractor.

Appropriate reference on drawing. Y 06/02/2018 Michail Tziolas

003 Construction Retaining Wall 5 -

contiguous bored piles wall

Working with concrete - conventional foundations/

RC cantilever walls require handling of large volumes

of concrete including placing at height of shutters for

the walls. Shuttering requires significant temporary

works. Also large reinforcement cages introduces

risks associated with impaling/ heavy lifting of bars,

working at heights etc.

Designer Use of bored piled walls reduces in-situ concrete works for

the substructure elements. Pilling eliminates shuttering and

reduces reinforcement to simpler reinforcement cages that

can be prepared and delivered from reinforcement yards off

site. This reduces the overall duration of works, hence

exposure to risks.

Design minimise need for temporary works. Top down method of contiguous bored pilled walls to

be defined on drawing and specification.

Y 06/04/2018 Michail Tziolas

004 Construction Retaining Wall 5 -

contiguous bored piles wall

Live road (A1 main line and slip roads) at risk of

falling debris during lifting operation of structural

elements.

Contractor Extra attention to prevent debris falling to A1 carriageway

and slip road during lifting operations.

TM to be in place during works with the crane.

Contractor to ensure TM details to be approved

prior to undertaking site based operations.

Note on drawings to be provided highlighting the

need for road closures or traffic management during

lifting operations.

N 06/02/2018 Rakesh Mehta

005 Construction Retaining Wall 5 -

contiguous bored piles wall

Working adjacent to services. Damage to existing

services, electrocution.

Contractor Statutory undertakers information indicate that services

are located within the vicinity of retaining walls and may

potentially be affected by the works.

Statutory undertakers searches/consultation to be

undertaken prior to detailed design (on-going). This is to

enable requirements for diversion/protection to be

determined. This should be reviewed by contractor prior to

undertaking works.

At this stage it is assumed that all services found

affecting the proposed retaining wall works shall

be diverted/ protected accordingly to progress the

retaining wall works on site. During construction,

areas to be scanned by trained and competent

contractor to confirm no presence of services

prior to works. Contractor to locate any services

present using hand tools before mechanical

excavation can commence. Contractor to also

liaise with the statutory undertakers/local

authorities and the HE maintenance service

providers to locate all services prior to piling or

excavation works. Contractor to implement safe

system. All excavation to be examined prior to

use.

Appropriate note/reference to be put on drawings

relating to service location at detailed design.

Y 06/02/2018 Michail Tziolas

006 Construction Retaining Wall 5 -

contiguous bored piles wall

Transport of large components - potential risks

associated with the movement of large abnormal

loads.

Contractor Detailed design to ensure the sections of walls

(reinforcement cages) are manageable (not excessively long

etc.) to ensure they can be delivered to site with minimal

potential logistical risks.

Contractor to provide assembly area as part of site

compound.

By ensuring the length of retaining wall sections are

not excessively large, would reduce risk associated

with transport and assembly on site.

N 06/02/2018 Michail Tziolas

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 5

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

12/04/2018 Page 1 of 4

Page 98: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 5

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

007 Construction Retaining Wall 5 -

contiguous bored piles wall

Site vehicles using public highways to transport

excess materials to disposal sites. Mud on roads,

airborne contamination during/after transit.

Contractor Identify agreed route where disruption will be minimised

and how the works areas will be accessed by construction

traffic during the works.

Wheel washing facility to be used on site to

minimise mud tracked onto road network.

Tarpaulins and straps to be checked before

deliveries leave site. Haulage of material to be

considered, in particular how to avoid/limit

disruption to the traffic during construction.

Contractor to plan all site deliveries and make

suppliers aware of these. To be defined in TTM plan.

N 06/02/2018 Michail Tziolas

008 Construction Retaining Wall 5 -

contiguous bored piles wall

Delivery material/structural components on site

cause obstruction lead to accidents (collision etc.)

Contractor Contractor to consider suitable holding areas on site in close

proximity to the works

Contractor to provide a suitable holding area as

part of the site compound.

No further action N 06/02/2018 Michail Tziolas

009 Maintenance Retaining Wall 5 -

contiguous bored piles wall

Struck by traffic during inspection works Operator Safe methods of work should be determined for all required

maintenance. Traffic management arrangements to be

determined before any work commences. The H&S

maintenance file should be consulted whilst planning the

required work

TM to be deployed when undertaking

inspection/maintenance type works. Details to be

provided in TTM plans.

SSOW to be deployed during

inspection/maintenance

N 06/02/2018 Michail Tziolas

010 Maintenance Retaining Wall 5 -

contiguous bored piles wall

Errant slip road vehicles/maintenance personnel

falling into the A1 or the slip roads from the raised

road levels.

Operator It is proposed that either a VRS be fixed along the top of the

retaining walls. Alternatively a safety barrier will be fixed

adjacent to the slip road edge (provide vehicle containment)

and a pedestrian parapet be provided along the top or

adjacent of the retaining wall (prevent falls from height).

Contractor to determine TM requirements for the

installation of parapets. Details to be documented

in TTM plans.

Add note on drawing to identify risk. N 06/02/2018 Michail Tziolas

011 Operation Retaining Wall 5 -

contiguous bored piles wall

Injury to driver upon impact with the retaining wall

face.

Operator Proposed retaining wall to be provided with a smooth finish

(in some cases cladding) and a VRS in front according to

TD19/06 - this reduces the severity of injury upon vehicular

impact.

Contractor to consider temporary works required

to fix cladding.

Appropriate reference on drawing. N 06/02/2018 Michail Tziolas

012 Construction Retaining Wall 5 -

contiguous bored piles wall

Pile failure during excavation of A1 slip road. Designer Design to ensure pile design incorporates the 'top-down'

construction philosophy with checks at each excavation

level.

Sequence of pile installation, to be designed and

specified in contract drawings.

Preliminary design indicates that the pile diameter

will be 750mm (max retained height approximately

3m) .The proposed pile diameter eliminates

additional maintenance activities associated with tie

back anchors and subsequently limits exposure to

H&S risks associated with undertaking maintenance

type work on live roads.

N 06/02/2018 Michail Tziolas

013 Construction Retaining Wall 5 -

contiguous bored piles wall

Lifting and installation of long reinforcement cages

for piles, risk associated with manual handling of

long/heavy rebar.

Contractor The reinforcement cages are to be specified such that they

can be pre-prepared off site and brought to site as required.

Appropriate cranage to be used with a lifting plan

to off load and install cages into piles.

Contractor to implement safe system. Ensure

sufficient working space to locate plant and

equipment. Risks associated with the

lifting/installation of long rebar cages to be added to

drawings.

Y 06/02/2018 Michail Tziolas

014 Construction Retaining Wall 5 -

contiguous bored piles wall

Hand arm vibration syndrome (HAVS) due to large

amount of on site pile cutting/trimming operations .

There is a risk to the workforce arising from the final

trimming of piles, this is more onerous with the

adoption of the top down construction method.

Contractor Design of piles with empty bores at the top to minimise the

removal of concrete

Use of machine rather than hand held tools Still a residual risk because there will be a small

amount of concrete that will need to be broken/cut

out. Contractor to develop SSOW/RAMS.

Y 06/02/2018 Michail Tziolas

12/04/2018 Page 2 of 4

Page 99: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 5

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

015 Construction Retaining Wall 5 -

contiguous bored piles wall

Adverse environment impact of using bentonite

slurry to support temporary excavation if piling is

carried out using percussive methods.

Designer Specify the use of either CFA piling or temporary casing of

piles to eliminate use of bentonite.

None Proposed piling system to be defined in design/AIP. N 06/02/2018 Michail Tziolas

016 Construction / Maintenance Retaining Wall 5 -

contiguous bored piles wall

Poorer than anticipated engineering properties of

the material behind the retaining wall resulting in

deflections of the structure beyond its serviceability

limits.

Designer Design to take into account the results of the ground

investigation, once completed, and sensitivity analysis

conducted where uncertainty exists.

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Based of the conclusions from the intrusive

ground investigation suitable design shall be

undertaken.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

ground conditions.

Y 05/04/2018 Ruth Jacobs

017 Construction Retaining Wall 5 -

contiguous bored piles wall

The proposed works may undermine / cause

instability within the existing earthworks.

Designer Additional temporary works my be required to prevent

instability of the existing embankment occurring during

construction of the retaining wall.

A review of HA GDMS and the Principal Earthwork

Inspection records held there. Intrusive

investigation undertaken to determine the

composition of the existing earthworks.

Temporary works designer to take into account the

presence of the existing earthworks.

Y 05/04/2018 Ruth Jacobs

018 Construction / Maintenance Retaining Wall 5 -

contiguous bored piles wall

Potential for coal mines cause collapse/increased

deflection of the retaining wall.

Designer Grouting of the worked coal seams below the retaining wall

may be required.

An intrusive ground investigation and coal mining

risk assessment to be undertaken to determine

the requirement for grouting.

Ground Investigation Report and Coal Mining Risk

Assessment reporting to be produced and confirm

the need for stabilisation works below the length of

the retaining wall structure.

Y 05/04/2018 Ruth Jacobs

019 Construction Retaining Wall 5 -

contiguous bored piles wall

Contaminated land or materials on site Contractor Assumed good practice will be carried out in site to prevent

material becoming contaminated. Unusual smells to be

notified to the supervising Engineer for assessment before

work continues. Spillage to be dealt with promptly by

identified methods. Appropriate PPE and induction. No

notable areas of contaminated land encountered during the

SI.

An intrusive ground investigation to be

undertaken to assess the ground conditions,

including undertaking geo-environmental testing.

The geo-environmental conditions anticipated to be

encountered on site shall be highlighted within the

Ground Investigation Report and subsequent design

report.

Y 05/04/2018 Ruth Jacobs

020 Construction Retaining Wall 5 -

contiguous bored piles wall

High groundwater levels (including perched

groundwater) causing excessive unfavourable actions

on retaining structure, leading to greater than

anticipated deflection of the embedded wall.

Designer Design to take into account the results of the ground

investigation, once completed, and sensitivity analysis

conducted where uncertainty exists.

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Groundwater monitoring to be undertaken as part

of the investigation. Based of the conclusions

from the intrusive ground investigation suitable

design shall be undertaken.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

groundwater conditions.

Y 05/04/2018 Ruth Jacobs

12/04/2018 Page 3 of 4

Page 100: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 5

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

Issue 1.0Copy rows then insert above this line to ensure formula are copied

12/04/2018 Page 4 of 4

Page 101: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX E-6

RW6 DESIGNERS RISK ASSESSMENT

Page 102: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

001 Construction Retaining Wall 6 -

Option F (King Post

Retaining Wall)

Open pile holes for king posts Contractor - Open pile holes to be protected as part of normal

management arrangements of contractor

Risk to be highlighted on drawings provided to the

contractor.

Y 06/02/2018 Michail Tziolas

002 Construction Retaining Wall 6 -

Option F (King Post

Retaining Wall)

Lifting and installation of long king post piles and

precast panels, risk associated with the lifting

operations and installation of the structural

elements.

Contractor King posts sections and panels cannot be eliminated,

precast panels could be increased in size to minimise

number of lifts but weight of individual lift then increases or

vice versa lighter lifts but more of them. Contractor to be

consulted to determine approch to best reduce risk.

Appropriate cranage to be used with a lifting plan

to off load and install king post sections into piles

and pre-cast concrete panels.

Contractor to implement safe system. Ensure

sufficient working space to locate plant and

equipment. Risks associated with the

lifting/installation of long steel sections and heavy

precast panels to be added to drawings.

Y 06/02/2018 Michail Tziolas

003 Construction / Maintenance Retaining wall 6 Poorer than anticipated engineering properties of

the material in front of and behind the retaining wall

resulting in deflections of the structure beyond its

serviceability limits.

Designer Design to take into account the results of the ground

investigation, once completed, and sensitivity analysis

conducted where uncertainty exists.

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Based of the conclusions from the intrusive

ground investigation suitable design shall be

undertaken.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

ground conditions.

Y 05/04/2018 Ruth Jacobs

004 Construction Retaining wall 6 The proposed works may undermine / cause

instability within the existing earthworks and the

access road at the crest of the cutting.

Designer Additional temporary works my be required to prevent

instability of the existing cutting occurring during

construction.

A review of HA GDMS and the Principal Earthwork

Inspection records held there. Intrusive

investigation undertaken to determine the

composition of the existing earthworks.

Temporary works designer to take into account the

presence of the existing earthworks.

Y 05/04/2018 Ruth Jacobs

005 Construction / Maintenance Retaining wall 6 Potential for coal mines cause collapse/increased

deflection of the retaining wall.

Designer Grouting of the worked coal seams below the retaining wall

may be required.

An intrusive ground investigation and coal mining

risk assessment to be undertaken to determine

the requirement for grouting.

Ground Investigation Report and Coal Mining Risk

Assessment reporting to be produced and confirm

the need for stabilisation works below the length of

the retaining wall structure.

Y 05/04/2018 Ruth Jacobs

006 Construction Retaining wall 6 Contaminated land or materials on site Contractor Assumed good practice will be carried out in site to prevent

material becoming contaminated. Unusual smells to be

notified to the supervising Engineer for assessment before

work continues. Spillage to be dealt with promptly by

identified methods. Appropriate PPE and induction. No

notable areas of contaminated land encountered during the

SI.

An intrusive ground investigation to be

undertaken to assess the ground conditions,

including undertaking geo-environmental testing.

The geo-environmental conditions anticipated to be

encountered on site shall be highlighted within the

Ground Investigation Report and subsequent design

report.

Y 05/04/2018 Ruth Jacobs

007 Construction Retaining wall 6 High groundwater levels (including perched

groundwater) causing excessive unfavourable

actions on retaining structure, leading to greater

than anticipated deflection of the embedded wall.

Designer Design to take into account the results of the ground

investigation, once completed, and sensitivity analysis

conducted where uncertainty exists.

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Groundwater monitoring to be undertaken as part

of the investigation. Based of the conclusions

from the intrusive ground investigation suitable

design shall be undertaken.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

groundwater conditions.

Y 05/04/2018 Ruth Jacobs

008 Construction Retaining wall 6 Depth to bedrock is higher than anticipated along

the length of the retaining wall resulting in the pile

holes being unable to reach design length.

Designer Design to take into account the results of the ground

investigation, once completed, including any variation in

rockhead level

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

ground conditions.

Y 05/04/2018 Ruth Jacobs

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 6

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

11/04/2018 Page 1 of 2

Page 103: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Project No 70015226 Project Name

Ref Risk Category* (and Phase where

appropriate, e.g.. location/environment,

construction, operation, maintenance,

alteration/demolition)

Work Element/Location

(where appropriate)

Hazard or Risk Issue Identified Risk Management

Owner

Design ERIC Action Required

(e.g.. hazard elimination/risk mitigation action, information

to be provided to others)

Significant Temporary Works

Requirements/Management Arrangements and/or

any Special Erection/Installation Sequences or

Requirements

Design Action Status/Final Resolution Notes

(e.g.. traceability of ERIC action, communication of

significant residual risk, critical design criteria, etc.)

Significant

Residual Risk§

(Y/N)

Date Logged/

Reviewed

Raised By

Way of Working: Project Delivery

T446: Design H&S Risk Register A1 Birtley to Coal House Improvement Scheme - Retaining Wall 6

Guidance notes (see guidance notes page for more details)

Design risk management should be an integral part of the overall design development and designers should think of it in terms of considering constructability, maintainability, etc. Designers only need to document their consideration of risks in this simple risk register format. There is no requirement for quantitative design risk assessments to be carried out/documented and these should be avoided

* Risks should be considered in a logical sequence relating to the location/operational environment, constructability/install ability, operability (normal/emergency), maintainability (inc. routine cleaning, replacement, etc.), and alteration/decommissioning/dismantling/demolition, and should be categorised against those headings,

CIRIA guidance documents C662, C663, C611, C607, etc. provide a useful checklist and detailed guidance on the identification of risks to be considered during design and how those risks might be addressed - see detailed guidance notes for more details§ Significant residual risks are those which are unusual, not obvious, difficult to manage, or where critical design assumptions apply. The documentation by designers of residual risks that cover well-known and understood hazards should be avoided

Provide Feedback

009 Construction Retaining wall 6 Depth to bedrock is lower than anticipated along the

length of the retaining wall resulting in the increase

in the length of the pile holes and increased

deflection of the retaining wall.

Designer Design to take into account the results of the ground

investigation, once completed, including any variation in

rockhead level

An intrusive ground investigation to be

undertaken to assess the ground conditions.

Ground Investigation Report to be provided.

Preliminary design to take account of anticipated

ground conditions.

Y 05/04/2018 Ruth Jacobs

Issue 1.0Copy rows then insert above this line to ensure formula are copied

11/04/2018 Page 2 of 2

Page 104: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Appendix F

KEY CORRESPONDENCE WITH HIGHWAYS ENGLAND

Page 105: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

APPENDIX F-1

KEY CORRESPONDENCE WITH HIGHWAYS ENGLAND

Page 106: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Structures Options Report Name of Project: A1 Birtley to Coalhouse

(Bridges and other Highway

Structures)

Name of Bridge/Structure: Retaining wall Structures Options Report

Structure Ref No: N/A

Safety Engineering & Standards (SES) Record Sheet

Scheme Name: A1 Birtley to Coalhouse Comments Sheet Document Control

Comment sheet version Date HA comment sheet Date Designer’s reply

sent Notes

Document Ref HA551462-WSP-SRW-BCH-RP-S-0001 A 26/03/18 09/04/18

B 09/04/18

SOR version C

D

SOR Date Feb 2018 E

No Section Initial comment (HE response) and further

comments on Designer’s reply

Designer’s reply Accepted

by HE

1 2.1.8 Replace “below” with “following” or reword. Noted to be amended.

2 2.3.1

2.3.2

2.3.3

These three paragraphs do not distinguish between

walls that are proposed to retain the highway and

walls that are proposed to retain land adjacent the

highway.

For walls that are to retain land adjacent the highway

there are options for their lateral clearance, such as:

Noted to be amended.

The retaining walls will differentiate

accordingly between the proposed walls that

retained the highway and the proposed walls

that retain the land adjacent the highway.

All the retaining wall that comprise a VRS at

the top of the wall will be designed for loading

Accepted

Page 107: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Position 4.5m back from carriageway

Position behind VRS

Position wall in line with VRS

As well as “retaining walls with a VRS would need

to be designed to sustain impact loading from

attached VRS”, retaining walls without VRS that

retaining land above the highway would also need to

be designed for impact loading.

created from the parapet in the unlikely event of

a collision.

In addition all the walls will be designed

according to BS EN 1991-1-7:2006+A1:2014

and NA+A1:2014 to BS EN 1991-1-

7:2006+A1:2014, chapter 4.3.1 Impact on

supporting substructures. The above covers the

accidental actions caused by road vehicles and

provide the accidental impact loading on

supporting structures.

Details of the above shall be made clear in

section 2.3 of the report.

3 2.3.4 In table 1 for retaining walls 4, 5 and 6 it is stated

”if a smooth surface is not provided then a safety

barrier should be placed in front of the wall at a

distance which satisfies the working width of the

barrier”

Whilst this statement is correct, it only really applies

when removing barrier in front of existing structures,

all new structures should be constructed smooth for

the bottom 1.5m regardless of VRS protection.

Noted to be amended.

Report shall make it clear the bottom 1.5m of

the wall structures shall have a smooth face in

accordance with TD19/06 irrespective of a

safety barrier provision.

Accepted

4 2.3.5 “safety barrier versus a VRS ? Typo mistake, the paragraph should of read:

Accepted

Page 108: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

“It would be prudent to assess and compare the

benefits of providing a safety barrier or a

smooth traffic face provision to retaining

structures, as this will impact the cost

effectiveness and buildability of the proposed

retaining wall options.”

However this paragraph is no longer applicable

as comment 3 states that a smooth surface

would be provided irrespective of a barrier

provision.

Text to be amended accordingly.

5 3.1.2 Options not mentioned are:

Reinforced soil slope

Slope regrading

Modular gravity retaining wall

Reinforced Earth Wall (also known as

reinforced soil walls) has been proposed as a

solution.

At this stage of the project, slope regrading has

not been considered. Once a source of material

has been sought, increased slope gradients could

be considered during the detailed

design/construction stage.

Steeper earthwork slopes are being advised

against at this stage in the project by the

landscaping team due to vegetation planting and

Accepted

Page 109: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

maintenance.

Modular gravity retaining walls and reinforced

soil slopes generally require more extensive

temporary excavation and traffic management

due to the proximity of the live carriageway

during installation. There is also a perceived

difficulty in promoting vegetation growth on

steep slopes in some locations. Also, modular

gravity retaining wall solution requires backfill

material which has significant material

transportation and will be potentially clash with

adjacent works or structures.

Clause 3.1.4-3.1.5 of the report provided details

of why gravity type walls was not considered in

detail for the mainline retaining wall options.

6 3.2.2 “Galvanised”, Is this practical?

“rusting” (corrosion) caused by presence of ground

water, plus salt splash from carriageway.

Typo mistake, reference to galvanised is

incorrect. It is proposed that a sacrificial

thickness be provided to the sheet piles to

counter against corrosion due to ground water.

Paragraph 3.2.2 to be amended accordingly.

Accepted

7 3.2.5

3.4.3

Are the drainage or weep holes to prevent build-up

of water behind walls to ensure earth pressures

behind walls in service are as assumed in design

calculations (i.e. drained parameters)?

During the detailed design of the retaining walls

appropriate drained parameters based on the

intrusive ground investigation results will be

considered.

Accepted

Page 110: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Drainage is required to prevent porewater

pressure build up behind the retaining walls.

Above to be made clear in clause 3.2.5 and 3.4.3

accordingly.

8 Table 2

Table 3

Disadvantages and risk:

Add need for piling platform

Noted to be amended. Should just read

disadvantage. Reference to piling platform to

also be added.

Accepted

9 Table 5 Disadvantages and Risk:

Add 0nly suitable when situated behind VRS

Noted to be amended. Should just read

disadvantage. Reference regarding the VRS to

be incorporated.

Accepted

10 Table 6 In the advantages/disadvantages it is not clear if

Reinforced Earth walls are sensitive to ground

conditions for their suitability.

Statement in disadvantages “requires suitable ground

conditions” applies surely to all retaining wall

options, except reinforced earth retaining walls are

the least sensitive to ground conditions.

Please consider rewording.

Noted to be amended to suit the comments. Accepted

11 5.6.3 Footbridge? Typo mistake, the amended wording should be:

“Footprint”

Accepted

12 General Retaining wall options such as sheet piles and Based on further discussions with Shaun and Accepted

Page 111: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

(Shaun Clarke) contiguous bored piles are suggested for retained

heights as low as 300mm.

In the D&B environment of PCF stage 5 it is

unlikely that these options will be considered or

constructed.

Have modular gravity retaining walls been

considered for low retained heights?

Have regrading of slopes been considered to remove

need for retaining walls of low retained height?

Has small movements in scheme boundary been

considered to remove need for retaining walls of low

retained height (we accept that this is not possible or

practical in some instances)?

Martin (HE SES Geotech and Structures

representatives).

The extent of the discrete mainline retaining

wall lengths shall be reviewed and where

practical retaining walls less than 1.5m retaining

height shall be considered to be Contractor

designed elements.

This is considered acceptable on the basis that

BD2/12 only recognises structures greater than

1.5m retained height as official highway

structures.

In this instance, it will be the Contractors

responsibility to use the most suitable

construction method (modular gravity wall,

slope regrading or remove of retaining wall etc.

The SOR shall be reviewed and changes shall be

incorporated to both the text and drawings based

on the above.

13 Estimates

(Shaun Clarke)

Can you explain how the estimates were calculated.

What would usually be considered as the lowest cost

option (reinforced earth) is almost twice as

expensive as what would usually be considered the

highest cost option (bored contiguous piles). For

The cost estimates were based on previous

similar type works and high level costing

information provided by suppliers who

specialise in particular retaining wall systems.

Accepted

Page 112: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

instance:

Breakdown on a cost/m basis

RW1 320m/£750k = £2.34k/m

RW2 100m/£300k = £3k/m

RW3 171m/£850k = £4.97k/m

RW4 156m/£400k = £2.56k/m

RW5 171m/£500k = £2.92k/m

RW6 300m/£559k = £1.83k/m

We appreciate that if you were to determine the

cost based on a m run it would appear that the

RE for RW3 and RW4 is expensive. However

this would not take into consideration the

different heights of the various wall types and

therefore does not provide a true cost

comparison.

For example taking into account the max

retained height the cost per m2 face would

approximate to the following:

RW1 320m/£750k = £2.34k/m – ht 2.5m –

Approx £1k/m2 L Cantilever

RW2 100m/£300k = £3k/m – ht 1.6m –

Approx £1.9k/m2 Sheet Pile

RW3 171m/£850k = £4.97k/m – ht 6.0m –

Approx £0.82k/m2 RE Wall

RW4 156m/£400k = £2.56k/m – ht 4.2m –

Approx £0.61k/m2 RE Wall

RW5 171m/£500k = £2.92k/m –ht 2.8m –

Approx £1.05k/m2 Sheet/Contig wall

RW6 300m/£559k = £1.83k/m – ht 2.5m –

Approx £0.74k/m2 King Post Wall

From the above it would demonstrate that the

RE solution would be the most cost effective per

m2 face.

The other reason why the contig wall option

Page 113: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

(RW5) cost is not as high as maybe expected is

because it is part of a hybrid solution (combined

Sheet/Contig wall) which further reduces the

cost of this option in comparison to if it was a

pure contig wall solution.

The option costs shall be reviewed during the

amendment of the SOR to incorporate HE

comments as tabulated.

It is expected that the total cost for some of the

discrete walls shall reduce as a result of the

response to comment no.12.

Page 114: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised
Page 115: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Planning Inspectorate Scheme Ref: TR010031Application Document Ref: TR010031/APP/2.1

Planning Inspectorate Scheme Ref: [Reference number allocated by the Planning Inspectorate] Page 2Application Document Ref: TR0100xx/APP/2.1

If you need help accessing this or any other Highways England information,please call 0300 470 4580 and we will help you.

© Crown copyright 2019.You may re-use this information (not including logos) free of charge inany format or medium, under the terms of the Open GovernmentLicence. To view this licence:visit www.nationalarchives.gov.uk /doc/open-government-licence/write to the Information Policy Team, The National Archives,Kew, London TW9 4DU, or [email protected].

This document is also available on our website at www.gov.uk /highways

If you have any enquiries about this document [email protected] call 0300 470 4580*.

*Calls to 03 numbers cost no more than a national rate call to an 01 or02 number and must count towards any inclusive minutes in thesame way as 01 and 02 calls.These rules apply to calls from any type of line including mobile, BT, other fixed line orpayphone. Calls may be recorded or monitored.

Registered office Bridge House, 1 Walnut Tree Close, Guildford GU1 4LZHighways England Company Limited registered in England and Wales number 09346363

Page 116: A1 Birtley to Coal House Scheme Number: TR010031... · Prepared by Michail Tziolas Michail Tziolas Signature MTz MTz Checked by Hitan Mistry Hitan Mistry Signature HM HM Authorised

Planning Inspectorate Scheme Ref: TR010031Application Document Ref: TR010031/APP/2.1

Planning Inspectorate Scheme Ref: [Reference number allocated by the Planning Inspectorate] Page 2Application Document Ref: TR0100xx/APP/2.1

If you need help accessing this or any other Highways England information,please call 0300 470 4580 and we will help you.

© Crown copyright 2019.You may re-use this information (not including logos) free of charge inany format or medium, under the terms of the Open GovernmentLicence. To view this licence:visit www.nationalarchives.gov.uk /doc/open-government-licence/write to the Information Policy Team, The National Archives,Kew, London TW9 4DU, or [email protected].

This document is also available on our website at www.gov.uk /highways

If you have any enquiries about this document [email protected] call 0300 470 4580*.

*Calls to 03 numbers cost no more than a national rate call to an 01 or02 number and must count towards any inclusive minutes in thesame way as 01 and 02 calls.These rules apply to calls from any type of line including mobile, BT, other fixed line orpayphone. Calls may be recorded or monitored.