FED ALL CARGO COMPARTMENT TEMPERATURE CONTROL - ADJUSTMENT/TEST 1. Operational Test WARNING : BEFORE POWER IS SUPPLIED TO THE AIRCRAFT, MAKE CERTAIN THAT ELECTRICAL CIRCUITS UPON WHICH WORK IS IN PROGRESS ARE ISOLATED. A. Reason for the Job (1) To check operation of the cargo compartment temperature control system and interface with smoke detection system. B. Equipment and Materials ITEM DESIGNATION (1) Electrical Ground Power Unit - 3- Phase, 115/200 V, 400 Hz Referenced Procedures - (Ref. 24-41-00, P. Block 301 ) - (Ref. 33-17-00, P. Block 501 ) - (Ref. 31-51-00, P. Block 201 ) AC External Power Control Memorized Fault Annunciators ECAM Sxstem FED 401-405,407-414,423-430,443,445 POST SB 31-2059 for A/C 401-405,407-414,423-430,443,445 Referenced Procedures - (Ref. 24-41-00, P. Block 301 ) - (Ref. 32-00-00, P. Block 501 ) - (Ref. 33-17-00, P. Block 501 ) - (Ref. 31-51-00, P. Block 201 ) AC External Power Control Landing Gear - General Memorized Fault Annunciators ECAM System A310-200 AMM - CARGO COMPARTMENT TEMPERATURE CONTROL - ADJUSTMENT/TEST Revision 32.0 P.Blk EFFECTIVITY: FED ALL 21-64-00-05 Printed - Date: 12/11/12 Time: Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved. Page 1 of 106 JUN 01/2012

A310-200 AMM - techpubs.fedex.com · WARNING : BEFORE POWER IS ... ECAM System A310-200 AMM - CARGO COMPARTMENT TEMPERATURE CONTROL ... - press MFA RESET pushbutton - BULK/CARGO MFA

Embed Size (px)

Citation preview

FED ALLCARGO COMPARTMENT TEMPERATURE CONTROL - ADJUSTMENT/TEST

1. Operational Test

WARNING : BEFORE POWER IS SUPPLIED TO THE AIRCRAFT, MAKE CERTAINTHAT ELECTRICAL CIRCUITS UPON WHICH WORK IS IN PROGRESSARE ISOLATED.

A. Reason for the Job

(1) To check operation of the cargo compartment temperaturecontrol system and interface with smoke detection system.

B. Equipment and Materials

ITEM DESIGNATION

(1) Electrical Ground Power Unit - 3-Phase,

115/200 V, 400 Hz

Referenced Procedures

- (Ref. 24-41-00, P. Block 301 )

- (Ref. 33-17-00, P. Block 501 )

- (Ref. 31-51-00, P. Block 201 )

 

AC External Power Control

Memorized Fault Annunciators

ECAM Sxstem

FED 401-405,407-414,423-430,443,445POST SB 31-2059 for A/C 401-405,407-414,423-430,443,445

Referenced Procedures

- (Ref. 24-41-00, P. Block 301 )

- (Ref. 32-00-00, P. Block 501 )

- (Ref. 33-17-00, P. Block 501 )

- (Ref. 31-51-00, P. Block 201 )

 

AC External Power Control

Landing Gear - General

Memorized Fault Annunciators

ECAM System

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 1 of 106JUN 01/2012

FED ALL

C. Procedure

(1) Job Set-Up

(a) Connect electrical ground power unit and energizeaircraft electrical network (Ref. 24-41-00, P.Block 301 ) .

(b) Make certain that electronics racks ventilation iscorrect.

(c) Make certain that the following circuit breakersare closed:

PANEL SERVICE IDENT. LOCATION

FED 421-422,453-499

22VU

22VU

22VU

22VU

22VU

CARGO/SMOKE DET/WARN

CARGO/SMOKE DET/PWR SUPPLY

AVIONICS/SMOKE DET/DETECTORS

AVIONICS/SMOKE DET/DETECTORS

COMPT TEMP/CARGO ISOL VALVE BULK

46WH

35WH

1WA

2WA

2HN

209/A25

209/A26

204/F25

204/F26

203/G28

FED 416-419

22VU

22VU

22VU

AVIONICS/SMOKE DET/DETECTORS

AVIONICS/SMOKE DET/DETECTORS

COMPT TEMP/CARGO ISOL VALVE BULK

1WA

2WA

2HN

204/F25

204/F26

203/G28

FED 423-430,443,445-450

22VU

22VU

22VU

22VU

22VU

22VU

CARGO SMOKE DET/WARN

CARGO SMOKE DET/PWR SUPPLY

AVIONICS SMOKE DET/DETECTORS

AVIONICS SMOKE DET/DETECTORS

COMPT TEMP/CARGO ISOL VALVES/FWD

COMPT TEMP/CARGO ISOL VALVES/BULK

46WH

35WH

1WA

2WA

40HN

2HN

209/A25

209/A26

204/F25

204/F26

203/G27

203/G28

FED 401-405,407-414,431-436,451-452

22VU

22VU

22VU

22VU

AVIONICS SMOKE DET/DETECTORS

AVIONICS SMOKE DET/DETECTORS

COMPT TEMP/CARGO ISOL VALVES/FWD

COMPT TEMP/CARGO ISOL VALVES/BULK

1WA

2WA

40HN

2HN

204/F25

204/F26

203/G27

203/G28

FED 416-422,453-499

125VU

 

AIR BLEED & COMPT TEMP/CARGO

COMPT EXTRACT FANS/BULK

37HN

 

504/G62

 

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 2 of 106JUN 01/2012

PANEL SERVICE IDENT. LOCATION

125VU

 

125VU

 

125VU

AIR BLEED & COMPT TEMP/COMPT

TEMP/CARGO/BULK/AUTO/CTL

AIR BLEED & COMPT TEMP/COMPT

TEMP/CARGO/BULK/MAN/CTL

AIR BLEED & COMPT TEMP/DEMAND/TEMP/CTL

5HN

 

4HN

 

7HH

503/H65

 

503/H66

 

502/J64

FED 401-405,407-414,423-436,443,445-452

125VU

 

125VU

 

125VU

 

125VU

 

125VU

 

125VU

 

125VU

AIR BLEED & COMPT TEMP/CARGO

COMPT EXTRACT FANS/BULK

AIR BLEED & COMPT TEMP/CARGO

COMPT EXTRACT FANS/FWD

AIR BLEED & COMPT TEMP/COMPT

TEMP/CARGO/FWD/AUTO/CTL

AIR BLEED & COMPT TEMP/COMPT

TEMP/CARGO/FWD/MAN/CTL

AIR BLEED & COMPT TEMP/COMPT

TEMP/CARGO/BULK/AUTO/CTL

AIR BLEED & COMPT TEMP/COMPT

TEMP/CARGO/BULK/MAN/CTL

AIR BLEED & COMPT TEMP/DEMAND/TEMP/CTL

37HN

 

41HN

 

43HN

 

42HN

 

5HN

 

4HN

 

7HH

504/G62

 

504/G65

 

503/H63

 

503/H64

 

503/H65

 

503/H66

 

502/J64

FED 416-422,453-499

129VU

129VU

129VU

129VU

129VU

129VU

LIGHTING/MAINT PANEL/ANN & MFA

LIGHTING/MAINT PANEL/ANN & MFA

LIGHTING/INT LT/ANN LT/TEST/MAN

LIGHTING/INT LT/ANN LT/TEST/MAN

LIGHTING/INT LT/ANN LT/TEST/MAN

LIGHTING/INT LT/ANN LT/TEST/AUTO

1WB

22WB

149LP

2LP

1LP

153LP

903/S90

903/S91

902/T88

902/T89

902/T90

902/T91

FED 401-405,407-414,423-436,443,445-452

129VU

129VU

129VU

129VU

129VU

129VU

LIGHTING/MAINT PANEL/ANN & MFA

LIGHTING/MAINT PANEL/ANN & MFA

LIGHTING/ANN LT/TEST/MAN

LIGHTING/ANN LT/TEST/MAN

LIGHTING/ANN LT/TEST/MAN

LIGHTING/ANN LT/TEST/AUTO

1WB

22WB

149LP

2LP

1LP

153LP

903/S90

903/S91

902/T88

902/T89

902/T90

902/T91

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 3 of 106JUN 01/2012

FED ALL

(d) Start ECAM system (Ref. 31-51-00, P. Block 201 )

(e) Test FANS MONITOR MFAs (Ref. 33-17-00, P. Block501 ) .

FED 416-422,453-499

(2) Test

(a) Test operation of BULK cargo compartment isolationvalve 19HN, extraction fan 30HN, and FANS MONITORMFA 8HN.

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO temperature selector switch 14HNis in MAN position.

- BULK CARGO/ISOL VALVE pushbutton switch 6HNis released OFF.

On maintenance panel 472VU:

- ANN LT toggle switch 2WB is in READposition.

2) Perform test.

(2)FED 401-405,407-414,423-436,443,445-452

Test

NOTE : Following tests apply for both FWD and BULKcargo compartments.Component FINs for FWD compartment are shownin brackets.

(a) Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), extraction fan 30HN(48HN), and FANS MONITOR MFA 8HN (57HN).

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) isreleased OFF.

On maintenance panel 472VU:

- ANN LT toggle switch 2WB is in READposition.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 4 of 106JUN 01/2012

2) Perform test.

FED 416-422,453-499 --------------------------------------------------------------------------------

ACTION RESULT

--------------------------------------------------------------------------------

1. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- press BULK CARGO/ISOL VALVE - OFF/R legend goes off.

pushbutton switch 6HN. - for duration of isolation valve

flap movement, ISOL VALVE push-

button switch FAULT legend

comes on and then goes off.

On R ECAM display - AIR COND page:

- isolation valve opens,

- isolation valve color : green.

On maintenance panel 472VU:

- check that BULK/CARGO MFA does not

come on.

- rotate and hold BULK CARGO temp On R ECAM display - AIR COND page:

selector switch 14HN in MAN-HOT - trim air valve flap position arrow

position until trim air valve flap remains stationary.

position arrow, on R ECAM display -

AIR COND page, is between H and C,

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 5 of 106JUN 01/2012

then release selector switch.

2. On circuit breaker panel 125VU:

- at location G62 open circuit - trim air valve flap position arrow

breaker 37HN. moves to C.

On maintenance panel 472VU:

- BULK/CARGO MFA comes on.

- close circuit breaker 37HN. - BULK/CARGO MFA remains on.

3. On maintenance panel 472VU:

- press MFA RESET pushbutton - BULK/CARGO MFA goes off.

switch 20WB.

4. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- release BULK CARGO/ISOL VALVE - OFF/R legend comes on.

pushbutton switch 6HN. - for duration of isolation valve

flap movement, ISOL VALVE push-

button switch FAULT legend comes

on and then goes off.

On R ECAM display - AIR COND page:

- isolation valve closed,

- isolation valve color : amber.

On maintenance panel 472VU:

- check that BULK/CARGO MFA does

not come on.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 6 of 106JUN 01/2012

FED 401-405,407-414,423-436,443,445-452 1. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- press BULK CARGO/ISOL VALVE - OFF/R legend goes off.

(FWD GARGO/ISOL VALVE)push- - for duration of isolation valve

button switch 6HN (52HN). movement, ISOL VALVE pushbutton

switch FAULT legend comes on and

then goes off.

On R ECAM display - AIR COND page:

- isolation valve opens,

- isolation valve color : green.

On maintenance panel 472VU:

- check that BULK/CARGO (FWD/CARGO)

MFA does not come on.

- rotate and hold BULK CARGO On R ECAM display - AIR COND page:

(FWD CARGO) temperature selector - trim air valve flap position arrow

switch 14HN (53HN) in MAN-HOT remains stationary.

position until trim air valve

flap position arrow, on R ECAM

display - AIR COND page, is be-

tween H and C, then release

selector switch.

2. On circuit breaker panel 125VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 7 of 106JUN 01/2012

- at location G62 open circuit - trim air valve flap position arrow

breaker 37HN moves to C.

- (at location G65 open circuit

breaker 41HN).

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA comes

on.

- close circuit breaker 37HN (41HN). - BULK/CARGO (FWD/CARGO) MFA remains

on.

3. On maintenance panel 472VU:

- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes

switch 20WB. off.

4. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- release BULK CARGO/ISOL VALVE - OFF/R legend comes on.

(FWD CARGO/ISOL VALVE) push- - for duration of isolation valve

button switch 6HN (52HN). flap movement, ISOL VALVE push-

button switch FAULT legend comes

on and then goes off.

On R ECAM display - AIR COND page:

- isolation valve closed,

- isolation valve color : amber.

On maintenance panel 472VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 8 of 106JUN 01/2012

- check that BULK/CARGO (FWD/CARGO)

MFA does not come on.

FED 416-422,453-499

(a) Carry out BITE-Test for cargo compartmenttemperature control system.

NOTE : - Test equipment is located in avionicscompartment at equipment rack 91VU.

1) Initial conditions:On COMPT TEMP panel 437VU:

- PACK VALVE 1 and 2 pushbutton switches191HB and 189HB are pressed in.

- BULK CARGO/ISOL VALVE pushbutton switch 6HNis pressed in.

- BULK CARGO temperature selector switch 14HNis in AUTO position.

- HOT AIR SUPPLY pushbutton switch 4HJ ispressed in.

2) Perform test.-------------------------------------------------------------------------------

ACTION RESULT

-------------------------------------------------------------------------------

1. At rack 91VU, on APU and pack temp On APU and pack temp demand

demand controller 37HK: controller 37HK:

- check that electrical power is - light comes on when pressed.

available at APU and pack temp

demand controller by pressing

BITE READY/UNPLUG CABLE AFTER

USE light,

- make certain that BITE SWITCH

is in position 1.

2. On circuit breaker panel 125VU:

- at location H65 open circuit

breaker 5HN.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 9 of 106JUN 01/2012

3. On BULK CARGO compt temp controller 15HN:

- remove BITE connector protective

cap.

- connect test cable of APU

and pack temperature demand

controller 37HK to BITE connector.

4. On circuit breaker panel 125VU: On APU and pack temp demand

controller:

- at location H65 close circuit - BITE READY/UNPLUG CABLE AFTER USE

breaker 5HN. and GO indicator lights come on.

5. On APU and pack temperature demand

controller:

- press NO GO indicator light. - NO GO integral light comes on.

- place BITE SWITCH to positions - for each position selected,

1 thru 12 in sequence, pausing GO indicator light must come on.

at each position until either

GO or NO GO light comes on.

NOTE : A NO GO light shows a failure

in the cargo compartment

temperature control system.

NOTE : Position 1 - Sum of outputs of pack scaling amplifiers is checked.

Position 2 - APU speed demand signal for maximum cooling is checked.

Position 3 - APU speed demand signal for maximum heating is checked.

Position 4 - Bridge power supply is checked.

Position 5 - Amplifier output is checked.

Position 6 - Drives actuator in more heat direction.

Position 7 - Overrides bridge output with signal to produce maximum

cooling output.

Position 8 - Overrides bridge output with signal to produce maximum

heating output.

Position 9 - Overrides bridge output to produce a 'nulled' output.

Position 10 - Output of bridge is checked.

Position 11 - Output of bridge is checked.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 10 of 106JUN 01/2012

Position 12 - Selector output signal is checked.

- return BITE SWITCH to position 1.

6. On circuit breaker panel 125VU: On APU and pack temperature demand

controller:

- at location H65 open circuit - BITE READY/UNPLUG CABLE AFTER USE

breaker 5HN. and GO indicator lights go off.

7. On BULK CARGO compt temp controller:

- disconnect test cable and secure

to dummy connector 103VC.

- secure protective cap.

8. On circuit breaker panel 125VU:

- at location H65 close circuit

breaker 5HN.

FED 431-436,451-452

(b) Carry out BITE-Test for cargo compartmenttemperature control system.

NOTE : Test equipment is located in avionicscompartment at equipment rack 91VU.

1) Initial conditions:On COMPT TEMP panel 437VU:

- PACK VALVE 1 and 2 pushbutton switches191HB and 189HB are pressed in.

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in AUTO position.

- HOT AIR SUPPLY pushbutton switch 4HJ ispressed in.

2) Perform test.-------------------------------------------------------------------------------

ACTION RESULT

-------------------------------------------------------------------------------

1. At rack 91VU, on APU and pack temp On APU and pack temp demand

demand controller 37HK: controller 37HK:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 11 of 106JUN 01/2012

- check that electrical power is - light comes on when pressed.

available at APU and pack temp

demand controller by pressing

BITE READY/UNPLUG CABLE AFTER

USE light.

- make certain that BITE SWITCH

is in position 1.

2. On circuit breaker panel 125VU:

- at location H65 open circuit

breaker 5HN.

- (at location H63 open circuit

breaker 43HN).

3. On BULK CARGO (FWD CARGO) compt

temp controller 15HN (54HN):

- remove BITE connector cap.

- connect test cable of APU

and pack temperature demand

controller 37HK to BITE connector.

4. On circuit breaker panel 125VU: On APU and pack temp demand

controller:

- at location H65 close circuit - BITE READY/UNPLUG CABLE AFTER

breaker 5HN. USE and GO indicator lights come

- (at location H63 close circuit on.

breaker 43HN).

5. On APU and pack temperature demand

controller:

- press NO GO indicator light. - NO GO integral light comes on.

- place BITE SWITCH to positions - for each position selected,

1 thru 12 in sequence, pausing GO indicator light must come on.

at each position until either

GO or NO GO light comes on.

NOTE : A NO GO light shows a failure

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 12 of 106JUN 01/2012

in the cargo compartment

temperature control system.

NOTE : Position 1 - Sum of outputs of pack scaling amplifiers is checked.

Position 2 - APU speed demand signal for maximum cooling is checked.

Position 3 - APU speed demand signal for maximum heating is checked.

Position 4 - Bridge power supply is checked.

Position 5 - Amplifier output is checked.

Position 6 - Drives actuator in more heat direction.

Position 7 - Overrides bridge output with signal to produce maximum

cooling output.

Position 8 - Overrides bridge output with signal to produce maximum

heating output.

Position 9 - Overrides bridge output to produce a 'nulled' output.

Position 10 - Output of bridge is checked.

Position 11 - Output of bridge is checked.

Position 12 - Selector output signal is checked.

- return BITE SWITCH to position 1.

6. On circuit breaker panel 125VU: On APU and pack temperature demand

controller:

- at location H65 open circuit - BITE READY/UNPLUG CABLE AFTER

breaker 5HN. USE and GO indicator lights go off.

- (at location H63 open circuit

breaker 43HN).

7. On BULK CARGO (FWD CARGO) compt

temp controller:

- disconnect test cable and secure

to dummy connector 103VC.

- Secure protective cap.

8. On circuit breaker panel 125VU:

- at location H65 close circuit

breaker 5HN.

- (at location H63 close circuit

breaker 43HN).

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 13 of 106JUN 01/2012

(b)FED 401-405,407-414,423-430,443,445-450

Carry out BITE-Test for cargo compartmenttemperature control system.

NOTE : Test equipment is located in avionicscompartment at equipment rack 91VU.

1) Initial conditions:On COMPT TEMP panel 437VU:

- PACK VALVE 1 and 2 pushbutton switches191HB and 189HB are pressed in.

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in AUTO position.

- HOT AIR SUPPLY pushbutton switch 4HJ ispressed in.

2) Perform test.-------------------------------------------------------------------------------

ACTION RESULT

-------------------------------------------------------------------------------

1. At rack 91VU, on APU and pack temp On APU and pack temp demand

demand controller 37HK: controller 37HK:

- check that electrical power is - light comes on when pressed.

available at APU and pack temp

demand controller by pressing

BITE READY/UNPLUG CABLE AFTER

USE light.

- make certain that BITE SWITCH

is in position 1.

2. On circuit breaker panel 125VU:

- at location H65 open circuit

breaker 5HN.

- (at location H63 open circuit

breaker 43HN).

3. On BULK CARGO (FWD CARGO) compt

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 14 of 106JUN 01/2012

temp controller 15HN (54HN):

- remove BITE connector cap.

- connect test cable of APU

and pack temperature demand

controller 37HK to BITE connector.

4. On circuit breaker panel 125VU: On APU and pack temp demand

controller:

- at location H65 close circuit - BITE READY/UNPLUG CABLE AFTER

breaker 5HN. USE and GO indicator lights come

- (at location H63 close circuit on.

breaker 43HN).

5. On APU and pack temperature demand

controller:

- press NO GO indicator light. - NO GO integral light comes on.

- place BITE SWITCH to positions - for each position selected,

1 thru 12 in sequence, pausing GO indicator light must come on.

at each position until either

GO or NO GO light comes on.

NOTE : A NO GO light shows a failure

in the cargo compartment

temperature control system.

NOTE : Position 1 - Sum of outputs of pack scaling amplifiers is checked.

Position 2 - APU speed demand signal for maximum cooling is checked.

Position 3 - APU speed demand signal for maximum heating is checked.

Position 4 - Bridge power supply is checked.

Position 5 - Amplifier output is checked.

Position 6 - Drives actuator in more heat direction.

Position 7 - Overrides bridge output with signal to produce maximum

cooling output.

Position 8 - Overrides bridge output with signal to produce maximum

heating output.

Position 9 - Overrides bridge output to produce a 'nulled' output.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 15 of 106JUN 01/2012

Position 10 - Output of bridge is checked.

Position 11 - Output of bridge is checked.

Position 12 - Selector output signal is checked.

- return BITE SWITCH to position 1.

6. On circuit breaker panel 125VU: On APU and pack temperature demand

controller:

- at location H65 open circuit - BITE READY/UNPLUG CABLE AFTER

breaker 5HN. USE and GO indicator lights go off.

- (at location H63 open circuit

breaker 43HN).

7. On BULK CARGO (FWD CARGO) compt

temp controller:

- disconnect test cable and secure

to dummy connector 103VC.

- Secure protective cap.

8. On circuit breaker panel 125VU:

- at location H65 close circuit

breaker 5HN.

- (at location H63 close circuit

breaker 43HN).

(c) Test operation of cold trim air valve 81HN (69HN).

1) Initial conditions:ON COMPT TEMP panel 437VU:

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.

2) Perform test.--------------------------------------------------------------------------------

ACTION RESULT

--------------------------------------------------------------------------------

1. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate and hold BULK CARGO - hot trim air valve flap position

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 16 of 106JUN 01/2012

(FWD CARGO) temp selector arrow remains stationary.

switch 14HN (53HN) in MAN-HOT

position until hot trim air valve

flap position arrow on R ECAM

display - AIR COND page is between

H and C, then release selector switch.

2. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow with scale appears.

3. ON COMPT TEMP panel 437VU:

- rotate and hold BULK CARGO - hot trim air valve flap position

(FWD CARGO) temp selector arrow moves to C, then cold trim

switch 14HN (53HN) in air valve flap position arrow

MAN-COLD position. moves to open position.

- release BULK CARGO (FWD CARGO) - both trim air valve flap position

temp selector switch 14HN (53HN). arrows remain stationary.

4. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold air valve flap position

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 17 of 106JUN 01/2012

arrow and scale disappear.

5. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- after approx. 30 seconds, check - FAULT legend must not come on.

FAULT legend of BULK (FWD) push-

button switch 80HN (78HN).

6. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate and hold BULK CARGO - hot trim air valve flap position

(FWD CARGO) temp selector switch arrow moves to H.

14HN (53HN) in MAN-HOT position.

- release BULK CARGO (FWD CARGO) - trim air valve flap position

temp selector switch. arrow remains stationary.

FED 416-422,431-436,451-499

(b) Not applicable.

FED 416-419

(c) Test operation of BULK cargo compartment isolationvalve 19HN, trim air valve 20HN and extraction fan30HN when SMOKE warning is simulated.

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO temperature selector switch 14HNis in MAN position.

- BULK CARGO/ISOL VALVE pushbutton switch 6HNis pressed in.

On maintenance panel 472VU:

- ANN LT toggle switch 2WB is in READposition.

2) Perform test.

(c)FED 421-422,453-499

Test operation of BULK cargo compartment isolationvalve 19HN, trim air valve 20HN and extraction fan30HN when SMOKE warning is simulated.

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO temperature selector switch 14HNis in MAN position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 18 of 106JUN 01/2012

- BULK CARGO/ISOL VALVE pushbutton switch 6HNis pressed in.

On maintenance panel 472VU:

- ANN LT toggle switch 2WB is in READposition.

On CARGO COMPT SMOKE DET panel 433VU:

- AFT/LOOP A 23WH, AFT/LOOP B 24WH, BULK/LOOPA 25WH and BULK /LOOP B 26WH pushbuttonswitches are pressed in.

2) Perform test.

FED 431-436,451-452

(d) Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), trim air valve 20HN(61HN) and extraction fan 30HN (48HN) when SMOKEwarning is simulated.

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.

On maintenance panel 472VU:

- ANN LT toggle switch 2WB is in READposition.

2) Perform test.

FED 401-405,407-414

(d) Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), hot trim air valve20HN (61HN), cold trim air valve 81HN (69HN) andextraction fan 30HN (48HN) when SMOKE warning issimulated.

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position .

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.

On maintenance panel 472VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 19 of 106JUN 01/2012

- ANN LT toggle switch 2WB is in READposition.

2) Perform test.

(d)FED 423-430,443,445-450

Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), hot trim air valve20HN (61HN), cold trim air valve 81HN (69HN) andextraction fan 30HN (48HN) when SMOKE warning issimulated.

1) Initial conditions:On COMPT TEMP panel 437VU:

- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.

- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.

On maintenance panel 472VU:

- ANN LT toggle switch 2WB is in READposition.

On CARGO COMPT SMOKE DET panel 433VU:

- FWD/LOOP A (21WH), FWD/LOOP B (22WH), AFT/LOOP A 23WH, AFT/LOOP B

- 24WH, BULK/LOOP A 25WH and BULK/LOOP B 26WHpushbutton switches are pressed in.

2) Perform test.

FED 453-499

--------------------------------------------------------------------------------

ACTION RESULT

--------------------------------------------------------------------------------

1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE

DET panel 433VU: DET panel 433VU:

- release BULK/LOOP B push- - OFF legend comes on.

button switch 26WH. On WLDP:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 20 of 106JUN 01/2012

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

BULK COMPT LOOP B OFF

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate and hold BULK CARGO - trim air valve opens fully and flap

temp selector switch 14HN in position arrow remains stationary

MAN-HOT position until trim at H.

air valve flap position arrow,

on R ECAM display - AIR COND

page, is at H, then release

selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton

selector switch 16WA to CARGO switch 52WA comes on.

COMPT/BULK position.

- place CARGO COMPT/LOOP TEST SEL

toggle switch 48WH to LOOP A

position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 21 of 106JUN 01/2012

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT pushbutton - BULK/SMOKE red warning light 12WH

switch 52WA. and LOOP A legend 25WH come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

ISOL VALVE pushbutton switch 6HN

FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and color

changes to amber.

- trim air valve flap position arrow

moves to position C.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 22 of 106JUN 01/2012

- BULK/SMOKE warning light and LOOP

A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

pushbutton switch 6HN. ISOL VALVE pushbutton switch

FAULT legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- trim air valve flap position arrow

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 23 of 106JUN 01/2012

remains at position C.

6. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO COMPT - TEST legend of PTT pushbutton

selector switch 16WA to NORM/FLT switch 52WA goes off.

position.

7. On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel

panel 433VU: 433VU:

- press BULK/LOOP B pushbutton - OFF legend goes off.

switch 26WH. On WLDP:

- LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B OFF

disappears.

FED 453-454,456-499

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 24 of 106JUN 01/2012

1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE

DET panel 433VU: DET panel 433VU:

- release BULK/LOOP B push- - OFF legend comes on.

button switch 26WH. On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

BULK COMPT LOOP B OFF

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate and hold BULK CARGO - trim air valve opens fully and flap

temp selector switch 14HN in position arrow remains stationary

MAN-HOT position until trim at H.

air valve flap position arrow,

on R ECAM display - AIR COND

page, is at H, then release

selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton

selector switch 16WA to CARGO switch 52WA comes on.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 25 of 106JUN 01/2012

COMPT/BULK position.

- place CARGO COMPT/LOOP TEST SEL

toggle switch 48WH to LOOP A

position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT pushbutton - BULK/SMOKE red warning light 12WH

switch 52WA. and LOOP A legend 25WH come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE

pushbutton switch 6HN

FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and color

changes to amber.

- trim air valve flap position arrow

moves to position C.

On L ECAM display:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 26 of 106JUN 01/2012

SMOKE

BULK CARGO COMPT SMOKE

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE warning light and LOOP

A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 27 of 106JUN 01/2012

pushbutton switch 6HN. ISOL VALVE pushbutton switch

FAULT legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- trim air valve flap position arrow

remains at position C.

6. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO COMPT - TEST legend of PTT pushbutton

selector switch 16WA to NORM/FLT switch 52WA goes off.

position.

7. On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel

panel 433VU: 433VU:

- press BULK/LOOP B pushbutton - OFF legend goes off.

switch 26WH. On WLDP:

- LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B OFF

disappears.

FED 416-436,443,445,451-499POST SB 31-2035 for A/C 423-435,443,445,453-499POST SB 31-2059 for A/C 423-430,443,445

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 28 of 106JUN 01/2012

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),

the ECAM SMOKE WARNING will include LAND ASAP for second priority of the

advisory.

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 29 of 106JUN 01/2012

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened,

then release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA comes on.

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

25WH (21WH) legend come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 30 of 106JUN 01/2012

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE

(FWD CARGO/ISOL VALVE) push-

button switch 6HN (52HN)

FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes

and color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On WLDP:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 31 of 106JUN 01/2012

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL - after isolation valve opens

VALVE (FWD CARGO/ISOL ISOL VALVE pushbutton switch FAULT

VALVE) pushbutton switch legend goes off.

6HN (52HN). On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

80HN (78HN). On L ECAM display:

MEMO

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 32 of 106JUN 01/2012

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap

position arrow with scale appears.

7. On COMPT TEMP panel 437VU:

- rotate and hold BULK - hot trim air valve flap position

CARGO (FWD CARGO) temp arrow remains at C and cold

selector switch 14HN (53HN) trim air valve flap position

in MAN-COLD position. arrow moves to position C.

- release BULK CARGO (FWD - cold trim air valve flap

CARGO) temp selector switch position arrow remains

14HN (53HN) when cold trim stationary.

air valve is approx. half opened.

8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

legend 25WH (21WH) come on.

On WLDP:

- SMOKE warning light flashes.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 33 of 106JUN 01/2012

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD CARGO/

ISOL VALVE) pushbutton switch 6HN

(52HN) FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On WLDP:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 34 of 106JUN 01/2012

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT

button switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

10. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 35 of 106JUN 01/2012

to NORM/FLT position.

11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On WLDP:

26WH (22WH). - LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF)

disappears.

12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

*Before SB 31-2035

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 36 of 106JUN 01/2012

*Before SB 31-2041

*Before SB 31-2059

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened,

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 37 of 106JUN 01/2012

then release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA comes on.

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

25WH (21WH) legend come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE

(FWD CARGO/ISOL VALVE) push-

button switch 6HN (52HN)

FAULT legend comes on.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 38 of 106JUN 01/2012

On R ECAM display - AIR COND page:

- isolation valve closes

and color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 39 of 106JUN 01/2012

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL - after isolation valve opens

VALVE (FWD CARGO/ISOL ISOL VALVE pushbutton switch FAULT

VALVE) pushbutton switch legend goes off.

6HN (52HN). On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 40 of 106JUN 01/2012

On R ECAM display - AIR COND page:

- cold trim air valve flap

position arrow with scale appears.

7. On COMPT TEMP panel 437VU:

- rotate and hold BULK - hot trim air valve flap position

CARGO (FWD CARGO) temp arrow remains at C and cold

selector switch 14HN (53HN) trim air valve flap position

in MAN-COLD position. arrow moves to position C.

- release BULK CARGO (FWD - cold trim air valve flap

CARGO) temp selector switch position arrow remains

14HN (53HN) when cold trim stationary.

air valve is approx. half opened.

8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

legend 25WH (21WH) come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD CARGO/

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 41 of 106JUN 01/2012

ISOL VALVE) pushbutton switch 6HN

(52HN) FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 42 of 106JUN 01/2012

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

disappears.

9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT

button switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

10. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

to NORM/FLT position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 43 of 106JUN 01/2012

11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On WLDP:

26WH (22WH). - LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF)

disappears.

12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

FED 423-430,443,445PRE SB 21-2015 for A/C 423-430,443,445PRE SB 31-2023 for A/C 423-430,443,445PRE SB 31-2035 for A/C 423-430,443,445

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 44 of 106JUN 01/2012

433VU: 433VU:

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF.

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened,

then release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 45 of 106JUN 01/2012

COMPT selector switch 16WA switch 52WA comes on.

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

25WH (21WH) legend come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- for duration of isolation valve

flap movement, BULK CARGO/ISOL

VALVE (FWD CARGO/ISOL VALVE)

pushbutton switch 6HN (52HN)

FAULT legend comes on and then

goes off.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 46 of 106JUN 01/2012

On R ECAM display - AIR COND page:

- isolation valve closes

and color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA

8HN (57HN) comes on.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 47 of 106JUN 01/2012

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL - for duration of isolation valve

VALVE (FWD CARGO/ISOL flap movement, ISOL VALVE push-

VALVE) pushbutton switch button switch FAULT legend comes on

6HN (52HN). and then goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA 8HN

(57HN) remains on.

6. On maintenance panel 472VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 48 of 106JUN 01/2012

- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes

switch 20WB. off and remains off.

7. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

8OHN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap

position arrow with scale appears.

8. On COMPT TEMP panel 437VU:

- rotate to and hold BULK - hot trim air valve flap position

CARGO (FWD CARGO) temp arrow remains at C and cold

selector switch 14HN trim air valve flap position

(53HN) in MAN-COLD posi- arrow moves to position C.

tion.

- release BULK CARGO (FWD - cold trim air valve flap

CARGO) temp selector switch position arrow remains

14HN (53HN) when cold trim stationary.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 49 of 106JUN 01/2012

air valve is approx. half opened.

9. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

legend 25WH (21WH) come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- for duration of isolation valve

flap movement, BULK CARGO/ISOL

VALVE (FWD CARGO/ISOL VALVE)

pushbutton switch 6HN (52HN)

FAULT legend comes on and

then goes off.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 50 of 106JUN 01/2012

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA

8HN (57HN) comes on.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 51 of 106JUN 01/2012

- LDG ELEVATION - 10,000 FT

disappears.

10. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - for duration of isolation valve

(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-

button switch 6HN (52HN). button switch FAULT legend comes on

and then goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

11. On maintenance panel 472VU: On maintenance panel 472VU:

- press MFA RESET push- - BULK/CARGO (FWD/CARGO) MFA

button switch 20WB. goes off.

12. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

to NORM/FLT position.

13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 52 of 106JUN 01/2012

433VU: 433VU:

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On WLDP:

26WH (22WH). - LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF

disappears.

14. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 8OHN (78HN). On L ECAM display:

- BULK CARGO COOLING ON

- (FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

** Before SB 21-2015

** Post SB 31-2023 For A/C 001-009, 501-501, 551-551

** Post SB 31-2035 For A/C 001-009, 501-501, 551-551

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 53 of 106JUN 01/2012

433VU: 433VU:

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened,

then release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 54 of 106JUN 01/2012

COMPT selector switch 16WA switch 52WA comes on.

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

25WH (21WH) legend come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- for duration of isolation valve

flap movement, BULK CARGO/ ISOL

VALVE (FWD CARGO/ISOL VALVE)

pushbutton switch 6HN (52HN)

legend comes on and then goes

off.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 55 of 106JUN 01/2012

On R ECAM display - AIR COND page:

- isolation valve closes

and color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA

8HN (57HN) comes on.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 56 of 106JUN 01/2012

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL - for duration of isolation valve

VALVE (FWD CARGO/ISOL flap movement, ISOL VALVE push-

VALVE) pushbutton switch button switch FAULT legend comes on

6HN (52HN). and then goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA 8HN

(57HN) remains on.

6. On maintenance panel 472VU:

- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes

switch 20WB. off and remains off.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 57 of 106JUN 01/2012

7. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap

position arrow with scale appears.

8. On COMPT TEMP panel 437VU:

- rotate to and hold BULK - hot trim air valve flap position

CARGO (FWD CARGO) temp arrow remains at C and cold

selector switch 14HN trim air valve flap position

(53HN) in MAN-COLD posi- arrow moves to position C.

tion.

- release BULK CARGO (FWD - cold trim air valve flap

CARGO) temp selector switch position arrow remains

14HN (53HN) when cold trim stationary.

air valve is approx. half opened.

9. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 58 of 106JUN 01/2012

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

legend 25WH (21WH) come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- for duration of isolation valve

flap movement, BULK CARGO/ISOL

VALVE (FWD CARGO/ISOL VALVE)

pushbutton switch 6HN (52HN)

FAULT legend comes on and

then goes off.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

On L ECAM display:

SMOKE

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 59 of 106JUN 01/2012

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA

8HN (57HN) comes on.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

10. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - for duration of isolation valve

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 60 of 106JUN 01/2012

(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-

button switch 6HN (52HN). button switch FAULT legend comes on

and then goes off.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA 8HN

(57HN) remains on.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

11. On maintenance panel 472VU: On maintenance panel 472VU:

- press MFA RESET push- - BULK/CARGO (FWD/CARGO) MFA

button switch 20WB. goes off.

12. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

to NORM/FLT position.

13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 61 of 106JUN 01/2012

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On WLDP:

26WH (22WH). - LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF

disappears.

14. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

- BULK CARGO COOLING ON

- (FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

** Before SB 31-2023

** Before SB 31-2035

** Post SB 21-2015 For A/C 001-001, 003-003, 008-009, 551-551

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 62 of 106JUN 01/2012

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened,

then release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA comes on.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 63 of 106JUN 01/2012

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

25WH (21WH) legend come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE

(FWD CARGO/ISOL VALVE) push-

button switch 6HN (52HN) FAULT

legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes

and color changes to amber.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 64 of 106JUN 01/2012

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 65 of 106JUN 01/2012

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL - after isolation valve opens

VALVE (FWD CARGO/ISOL ISOL VALVE pushbutton switch FAULT

VALVE) pushbutton switch legend goes off.

6HN (52HN). On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

8OHN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap

position arrow with scale appears.

7. On COMPT TEMP panel 437VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 66 of 106JUN 01/2012

- rotate and hold BULK - hot trim air valve flap position

CARGO (FWD CARGO) temp arrow remains at C and cold

selector switch 14HN (53HN) trim air valve flap position

in MAN-COLD position. arrow moves to position C.

- release BULK CARGO (FWD - cold trim air valve flap

CARGO) temp selector switch position arrow remains

14HN (53HN) when cold trim stationary.

air valve is approx. half opened.

8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA. warning light 12WH (1WH) and LOOP A

legend 25WH (21WH) come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD CARGO/

ISOL VALVE) pushbutton switch 6HN

(52HN) FAULT legend comes on.

On R ECAM display - AIR COND page:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 67 of 106JUN 01/2012

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 68 of 106JUN 01/2012

(FWD CARGO COMPT SMOKE)

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

disappears.

9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT

button switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

10. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

to NORM/FLT position.

11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On WLDP:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 69 of 106JUN 01/2012

26WH (22WH). - LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF)

disappears.

12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 8OHN (78HN). On L ECAM display:

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

FED 446,450POST SB 31-2035 for A/C 446,450

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On main instrument panels 3VU

and 5VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 70 of 106JUN 01/2012

- MASTER/CAUTION lights come on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF.

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened, then

release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA comes on.

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 71 of 106JUN 01/2012

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA: warning light 12WH (1WH) and

LOOP A legend 25WH (21WH) come on.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights flash.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD

CARGO/ISOL VALVE) pushbutton

switch 6HN (52HN) FAULT

legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 72 of 106JUN 01/2012

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights go off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 73 of 106JUN 01/2012

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT

pushbutton switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- hot trim air valve flap position

arrow remains at position C.

6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow with scale appears.

7. On COMPT TEMP panel 437VU:

- rotate and hold BULK CARGO - hot trim air valve flap position

(FWD CARGO) temp selector arrow remains at C and cold

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 74 of 106JUN 01/2012

switch 14HN (53HN) in trim air valve flap position arrow

MAN-COLD position. moves towards position C.

- release BULK CARGO - cold trim air valve flap position

(FWD CARGO) temp selector arrow remains stationary.

switch when cold trim air

valve is approx. half opened.

8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red warning

button switch 52WA. light 12WH (1WH) and LOOP A legend

25WH (21WH) come on.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights flash.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD

CARGO/ISOL VALVE) pushbutton

switch 6HN (52HN) FAULT

legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 75 of 106JUN 01/2012

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights go off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 76 of 106JUN 01/2012

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT

pushbutton switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

10. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

to NORM/FLT position.

11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On main instrument panels 3VU

26WH (22WH). and 5VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 77 of 106JUN 01/2012

- MASTER/CAUTION lights go off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF)

disappears.

12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

- BULK CARGO COOLING ON

- (FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

FED 447-449POST SB 31-2035 for A/C 447-449

1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.

pushbutton switch 26WH (22WH). On main instrument panels 3VU

and 5VU:

- MASTER/CAUTION lights come on.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 78 of 106JUN 01/2012

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

- BULK COMPT LOOP B - OFF.

- (FWD COMPT LOOP B - OFF)

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air valve

flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened, then

release selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA comes on.

to CARGO COMPT/BULK (CARGO

COMPT/FWD/1) position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 79 of 106JUN 01/2012

- place CARGO COMPT/LOOP TEST

SEL toggle switch 48WH to

LOOP A position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red

button switch 52WA: warning light 12WH (1WH) and

LOOP A legend 25WH (21WH) come on.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights flash.

In flight compartment:

-repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD

CARGO/ISOL VALVE) pushbutton

switch 6HN (52HN) FAULT

legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 80 of 106JUN 01/2012

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - BULK/SMOKE (FWD/SMOKE) red

warning light and LOOP A

legend go off.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights go off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 81 of 106JUN 01/2012

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT

pushbutton switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- hot trim air valve flap position

arrow remains at position C.

6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton switch - ON legend comes on.

80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow with scale appears.

7. On COMPT TEMP panel 437VU:

- rotate and hold BULK CARGO - hot trim air valve flap position

(FWD CARGO) temp selector arrow remains at C and cold

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 82 of 106JUN 01/2012

switch 14HN (53HN) in trim air valve flap position arrow

MAN-COLD position. moves towards position C.

- release BULK CARGO - cold trim air valve flap position

(FWD CARGO) temp selector arrow remains stationary.

switch when cold trim air

valve is approx. half opened.

8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red warning

button switch 52WA. light 12WH (1WH) and LOOP A legend

25WH (21WH) come on.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights flash.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD

CARGO/ISOL VALVE) pushbutton

switch 6HN (52HN) FAULT

legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 83 of 106JUN 01/2012

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock

(closed) position.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE (FWD/SMOKE) warning

light and LOOP A legend go off.

On main instrument panels 3VU

and 5VU:

- MASTER/WARNING lights go off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 84 of 106JUN 01/2012

- LDG ELEVATION - 10,000 FT

disappears.

9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT

pushbutton switch 6HN (52HN). legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

10. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton

COMPT selector switch 16WA switch 52WA goes off.

to NORM/FLT position.

11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel

433VU: 433VU:

- press BULK/LOOP B (FWD/ - OFF legend goes off.

LOOP B) pushbutton switch On main instrument panels 3VU

26WH (22WH). and 5VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 85 of 106JUN 01/2012

- MASTER/CAUTION lights go off.

On L ECAM display:

LOOP

BULK COMPT LOOP B - OFF

(FWD COMPT LOOP B - OFF)

disappears.

12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

- BULK CARGO COOLING ON

- (FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

FED 401-405,407-412POST SB 31-2059 for A/C 401-405,407-412

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

FED ALL

NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),

the ECAM SMOKE warning will include LAND ASAP for second priority

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 86 of 106JUN 01/2012

of the advisory.

1. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD - hot trim air valve opens and

CARGO) temp selector switch remains stationary, color:

14HN (53HN) to MAN-HOT posi- green.

tion, hold unil hot trim air

valve flap position arrow, on

R ECAM display - AIR COND page,

is at least half opened, then

release selector switch.

2. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA TEST

COMPT selector switch 16WA legend comes on.

to CARGO COMPT/BULK/1

(CARGO COMPT/FWD/1) position.

- press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU,

switch 52WA. after approx. 2-3 second delay:

- AFT & BULK/SMOKE (FWD/SMOKE)

red warning light 38WH (39WH)

comes on.

In flight compartment:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 87 of 106JUN 01/2012

- repetitive chime sounds.

On WLDP:

- SMOKE warning light flashes.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD

CARGO/ISOL VALVE) pushbutton switch

6HN (52HN) FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - AFT & BULK/SMOKE (FWD/SMOKE)

red warning light goes off.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 88 of 106JUN 01/2012

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

disappears.

3. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL - after isolation valve opens, ISOL

VALVE (FWD CARGO/ISOL VALVE pushbutton switch FAULT

VALVE) pushbutton switch legend goes off.

6HN (52HN). On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

4. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton - ON legend comes on.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 89 of 106JUN 01/2012

switch 80HN (78HN) On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow with scale appears.

5. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve flap

temperature selector switch position arrow remains at C and

14HN (53HN) to MAN COLD cold trim air valve flap

position. position arrow moves towards

position C.

- release BULK CARGO (FWD CARGO) - cold trim air valve flap

temp selector switch 14HN position arrow remains stationary.

(53HN) when cold trim air

valve 81HN (69HN) is approx.

half open.

6. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU,

- press and hold PTT pushbutton after approx. 2-3 second delay:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 90 of 106JUN 01/2012

switch 52WA. - AFT & BULK/SMOKE (FWD/SMOKE)

red warning lights 38WH (39WH)

comes on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE (FWD

CARGO/ISOL VALVE) pushbutton switch

6HN (52HN) FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock (closed)

position.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 91 of 106JUN 01/2012

- MAX FL - 100/MEA

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - AFT & BULK/SMOKE (FWD/SMOKE)

warning lights go off.

In flight compartment:

- repetitive chime stops.

On WLDP:

- SMOKE warning light goes off.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

disappears.

7. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT

pushbutton switch 6HN legend goes off.

(52HN). On R ECAM display - AIR COND page:

- isolation valve opens and

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 92 of 106JUN 01/2012

color changes to green.

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

8. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 80HN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

9. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA TEST

COMPT selector switch 16WA legend goes off.

to NORM/FLT position.

FED 413-414

FED ALL

FED ALL

FED ALL

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 93 of 106JUN 01/2012

FED ALL

FED ALL

FED ALLPOST SB 31-2059 for A/C 413-414

NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),

the ECAM SMOKE warning will include LAND ASAP for second priority

of the advisory.

1. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and

temp selector switch 14HN remains stationary, color: green.

(53HN) to MAN-HOT position,

hold until hot trim air

valve flap position arrow,

on R ECAM display - AIR COND

page, is at least half opened,

then release selector switch.

2. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA TEST

COMPT selector switch legend comes on.

16WA to CARGO COMPT/BULK/1

(CARGO COMPT/FWD/1) position.

- press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU,

switch 52WA. after 2-3 second delay:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 94 of 106JUN 01/2012

- AFT & BULK/SMOKE (FWD/SMOKE)

red warning light 38WH (39WH)

comes on.

In flight compartment:

- repetitive chime sounds.

On WLDP:

- SMOKE warning light flashes.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA 8HN

(57HN) comes on.

On COMPT TEMP panel 437VU:

- for duration of isolation valve

flap movement, BULK CARGO/ISOL

VALVE (FWD CARGO/ISOL VALVE)

pushbutton switch 6HN (52HN) FAULT

legend comes on and then goes off.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- hot trim air valve flap position

arrow moves to position C.

On L ECAM display:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 95 of 106JUN 01/2012

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

appears.

- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:

switch. - AFT & BULK/SMOKE (FWD/SMOKE)

warning light goes off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

disappears.

3. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - for duration of isolation valve

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 96 of 106JUN 01/2012

(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-

button switch 6HN (52HN) button switch FAULT legend comes

(release p/b sw and press on and then goes off.

again). On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA 8HN

(57HN) remains on.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

- hot trim air valve flap position

arrow remains at position C.

4. On maintenance panel 472VU: On maintenance panel 472VU:

- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA

switch 20WB. goes off.

5. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- press BULK (FWD) pushbutton - ON legend comes on.

switch 8OHN (78HN). On L ECAM display:

MEMO

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

appears.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 97 of 106JUN 01/2012

On R ECAM display - AIR COND page:

- cold trim air valve flap

position arrow with scale appears.

6. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate BULK CARGO (FWD CARGO) - hot trim air valve flap position

temperature selector switch arrow remains at C and cold

14HN (53HN) to MAN-COLD trim air valve flap position

position and hold. arrow moves to position C.

- release BULK CARGO (FWD CARGO) - cold trim air valve flap

temperature selector switch position arrow remains

14HN (53HN) when cold trim stationary.

air valve is approx. half open.

7. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU,

- press and hold PTT pushbutton after approx. 2-3 second delay:

switch 52WA. - AFT & BULK/SMOKE (FWD/SMOKE)

red warning light 38WH (39WH)

comes on.

In flight compartment:

- repetitive chime sounds.

On WLDP:

- SMOKE warning light flashes.

On COMPT TEMP panel 437VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 98 of 106JUN 01/2012

- for duration of isolation valve

flap movement, ISOL VALVE

pushbutton switch 6HN (52HN)

FAULT legend comes on and then

goes off.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA

8HN (57HN) comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and

color changes to amber.

- cold trim air valve flap position

arrow moves to 10 o'clock (closed)

position.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

appears.

- release PTT pushbutton On CARGO COMP SMOKE DET panel 433VU:

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 99 of 106JUN 01/2012

switch. - AFT & BULK/SMOKE (FWD/SMOKE)

red warning light goes off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

AFT & BULK CARGO COMPT SMOKE

(FWD CARGO COMPT SMOKE)

- LDG ELEVATION - 10,000 FT

- MAX FL - 100/MEA

disappears.

8. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - for duration of isolation valve

(FWD CARGO/ISOL VALVE) flap movement, ISOL VALVE push-

pushbutton switch 6HN (52HN). button switch FAULT legend comes

on and then goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and

color changes to green.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 100 of 106JUN 01/2012

- cold trim air valve flap position

arrow remains at 10 o'clock

(closed) position.

On maintenance panel 472VU:

- BULK/CARGO (FWD/CARGO) MFA 8HN

(57HN) remains on.

9. On maintenance panel 472VU:

- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA

switch 20WB. goes off.

10. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:

- release BULK (FWD) pushbutton - ON legend goes off.

switch 8OHN (78HN). On L ECAM display:

BULK CARGO COOLING ON

(FWD CARGO COOLING ON)

disappears.

On R ECAM display - AIR COND page:

- cold trim air valve flap position

arrow and scale disappear.

11. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA

COMPT selector switch TEST legend goes off.

16WA to NORM/FLT position.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 101 of 106JUN 01/2012

FED 453-499POST SB 31-2035 for A/C 453-499

1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE

DET panel 433VU: DET panel 433VU:

- release BULK/LOOP B push- - OFF legend comes on.

button switch 26WH. On WLDP:

- LOOP warning light comes on.

In flight compartment:

- single chime sounds.

On L ECAM display:

LOOP

BULK COMPT LOOP B OFF

appears.

2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:

- rotate and hold BULK CARGO - trim air valve opens fully and flap

temp selector switch 14HN in position arrow remains stationary

MAN-HOT position until trim at H.

air valve flap position arrow,

on R ECAM display - AIR COND

page, is at H, then release

selector switch.

3. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 102 of 106JUN 01/2012

selector switch 16WA to CARGO switch 52WA comes on.

COMPT/BULK position.

- place CARGO COMPT/LOOP TEST SEL

toggle switch 48WH to LOOP A

position.

4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:

- press and hold PTT pushbutton - BULK/SMOKE red warning light 12WH

switch 52WA. and LOOP A legend 25WH come on.

On WLDP:

- SMOKE warning light flashes.

In flight compartment:

- repetitive chime sounds.

On COMPT TEMP panel 437VU:

- BULK CARGO/ISOL VALVE

pushbutton switch 6HN

FAULT legend comes on.

On R ECAM display - AIR COND page:

- isolation valve closes and color

changes to amber.

- trim air valve flap position arrow

moves to position C.

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 103 of 106JUN 01/2012

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

appears.

- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:

- BULK/SMOKE warning light and LOOP

A legend go off.

On WLDP:

- SMOKE warning light goes off.

In flight compartment:

- repetitive chime stops.

On L ECAM display:

SMOKE

BULK CARGO COMPT SMOKE

- AGENT 1 - DISCH

- LDG ELEVATION - 10,000 FT

disappears.

5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:

- reset BULK CARGO/ISOL VALVE - after isolation valve opens,

pushbutton switch 6HN. ISOL VALVE pushbutton switch

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 104 of 106JUN 01/2012

FAULT legend goes off.

On R ECAM display - AIR COND page:

- isolation valve opens and color

changes to green.

- trim air valve flap position arrow

remains at position C.

6. On maintenance panel 471VU: On maintenance panel 471VU:

- rotate ELEC COMPT & CARGO COMPT - TEST legend of PTT pushbutton

selector switch 16WA to NORM/FLT switch 52WA goes off.

position.

7. On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel

panel 433VU: 433VU:

- press BULK/LOOP B pushbutton - OFF legend goes off.

switch 26WH. On WLDP:

- LOOP warning light goes off.

On L ECAM display:

LOOP

BULK COMPT LOOP B OFF

disappears.

FED 416-422,453-499

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0

P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.

Page 105 of 106JUN 01/2012

(3) Close-Up

(a) On maintenance panel 472VU, place ANN LT toggleswitch 2WB in OFF position.

(b) On ECAM control panel, release ECAM SGU 1 and 2pushbutton switches.

(c) On COMPT TEMP panel 437VU, rotate BULK CARGOtemperature selector switch 14HN to AUTO position.

(d) Make certain that working area is clean and clearof tools and miscellaneous items of equipment.

(e) De-energize aircraft electrical network anddisconnect electrical ground power unit (Ref.24-41-00, P. Block 301 ) .

(3)FED 401-405,407-414,423-436,443,445-452

Close-Up

(a) On maintenance panel 472VU, place ANN LT toggleswitch 2WB in OFF position.

(b) On ECAM control panel, release ECAM SGU 1 and 2pushbutton switches.

(c) On COMPT TEMP panel 437VU, rotate BULK CARGO (FWDCARGO) temperature selector switch 14HN (53HN) toAUTO position.

(d) Make certain that working area is clean and clearof tools and miscellaneous items of equipment.

(e) De-energize aircraft electrical network anddisconnect electrical ground power unit (Ref.24-41-00, P. Block 301 ) .

A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0