FED ALLCARGO COMPARTMENT TEMPERATURE CONTROL - ADJUSTMENT/TEST
1. Operational Test
WARNING : BEFORE POWER IS SUPPLIED TO THE AIRCRAFT, MAKE CERTAINTHAT ELECTRICAL CIRCUITS UPON WHICH WORK IS IN PROGRESSARE ISOLATED.
A. Reason for the Job
(1) To check operation of the cargo compartment temperaturecontrol system and interface with smoke detection system.
B. Equipment and Materials
ITEM DESIGNATION
(1) Electrical Ground Power Unit - 3-Phase,
115/200 V, 400 Hz
Referenced Procedures
- (Ref. 24-41-00, P. Block 301 )
- (Ref. 33-17-00, P. Block 501 )
- (Ref. 31-51-00, P. Block 201 )
AC External Power Control
Memorized Fault Annunciators
ECAM Sxstem
FED 401-405,407-414,423-430,443,445POST SB 31-2059 for A/C 401-405,407-414,423-430,443,445
Referenced Procedures
- (Ref. 24-41-00, P. Block 301 )
- (Ref. 32-00-00, P. Block 501 )
- (Ref. 33-17-00, P. Block 501 )
- (Ref. 31-51-00, P. Block 201 )
AC External Power Control
Landing Gear - General
Memorized Fault Annunciators
ECAM System
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 1 of 106JUN 01/2012
FED ALL
C. Procedure
(1) Job Set-Up
(a) Connect electrical ground power unit and energizeaircraft electrical network (Ref. 24-41-00, P.Block 301 ) .
(b) Make certain that electronics racks ventilation iscorrect.
(c) Make certain that the following circuit breakersare closed:
PANEL SERVICE IDENT. LOCATION
FED 421-422,453-499
22VU
22VU
22VU
22VU
22VU
CARGO/SMOKE DET/WARN
CARGO/SMOKE DET/PWR SUPPLY
AVIONICS/SMOKE DET/DETECTORS
AVIONICS/SMOKE DET/DETECTORS
COMPT TEMP/CARGO ISOL VALVE BULK
46WH
35WH
1WA
2WA
2HN
209/A25
209/A26
204/F25
204/F26
203/G28
FED 416-419
22VU
22VU
22VU
AVIONICS/SMOKE DET/DETECTORS
AVIONICS/SMOKE DET/DETECTORS
COMPT TEMP/CARGO ISOL VALVE BULK
1WA
2WA
2HN
204/F25
204/F26
203/G28
FED 423-430,443,445-450
22VU
22VU
22VU
22VU
22VU
22VU
CARGO SMOKE DET/WARN
CARGO SMOKE DET/PWR SUPPLY
AVIONICS SMOKE DET/DETECTORS
AVIONICS SMOKE DET/DETECTORS
COMPT TEMP/CARGO ISOL VALVES/FWD
COMPT TEMP/CARGO ISOL VALVES/BULK
46WH
35WH
1WA
2WA
40HN
2HN
209/A25
209/A26
204/F25
204/F26
203/G27
203/G28
FED 401-405,407-414,431-436,451-452
22VU
22VU
22VU
22VU
AVIONICS SMOKE DET/DETECTORS
AVIONICS SMOKE DET/DETECTORS
COMPT TEMP/CARGO ISOL VALVES/FWD
COMPT TEMP/CARGO ISOL VALVES/BULK
1WA
2WA
40HN
2HN
204/F25
204/F26
203/G27
203/G28
FED 416-422,453-499
125VU
AIR BLEED & COMPT TEMP/CARGO
COMPT EXTRACT FANS/BULK
37HN
504/G62
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 2 of 106JUN 01/2012
PANEL SERVICE IDENT. LOCATION
125VU
125VU
125VU
AIR BLEED & COMPT TEMP/COMPT
TEMP/CARGO/BULK/AUTO/CTL
AIR BLEED & COMPT TEMP/COMPT
TEMP/CARGO/BULK/MAN/CTL
AIR BLEED & COMPT TEMP/DEMAND/TEMP/CTL
5HN
4HN
7HH
503/H65
503/H66
502/J64
FED 401-405,407-414,423-436,443,445-452
125VU
125VU
125VU
125VU
125VU
125VU
125VU
AIR BLEED & COMPT TEMP/CARGO
COMPT EXTRACT FANS/BULK
AIR BLEED & COMPT TEMP/CARGO
COMPT EXTRACT FANS/FWD
AIR BLEED & COMPT TEMP/COMPT
TEMP/CARGO/FWD/AUTO/CTL
AIR BLEED & COMPT TEMP/COMPT
TEMP/CARGO/FWD/MAN/CTL
AIR BLEED & COMPT TEMP/COMPT
TEMP/CARGO/BULK/AUTO/CTL
AIR BLEED & COMPT TEMP/COMPT
TEMP/CARGO/BULK/MAN/CTL
AIR BLEED & COMPT TEMP/DEMAND/TEMP/CTL
37HN
41HN
43HN
42HN
5HN
4HN
7HH
504/G62
504/G65
503/H63
503/H64
503/H65
503/H66
502/J64
FED 416-422,453-499
129VU
129VU
129VU
129VU
129VU
129VU
LIGHTING/MAINT PANEL/ANN & MFA
LIGHTING/MAINT PANEL/ANN & MFA
LIGHTING/INT LT/ANN LT/TEST/MAN
LIGHTING/INT LT/ANN LT/TEST/MAN
LIGHTING/INT LT/ANN LT/TEST/MAN
LIGHTING/INT LT/ANN LT/TEST/AUTO
1WB
22WB
149LP
2LP
1LP
153LP
903/S90
903/S91
902/T88
902/T89
902/T90
902/T91
FED 401-405,407-414,423-436,443,445-452
129VU
129VU
129VU
129VU
129VU
129VU
LIGHTING/MAINT PANEL/ANN & MFA
LIGHTING/MAINT PANEL/ANN & MFA
LIGHTING/ANN LT/TEST/MAN
LIGHTING/ANN LT/TEST/MAN
LIGHTING/ANN LT/TEST/MAN
LIGHTING/ANN LT/TEST/AUTO
1WB
22WB
149LP
2LP
1LP
153LP
903/S90
903/S91
902/T88
902/T89
902/T90
902/T91
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 3 of 106JUN 01/2012
FED ALL
(d) Start ECAM system (Ref. 31-51-00, P. Block 201 )
(e) Test FANS MONITOR MFAs (Ref. 33-17-00, P. Block501 ) .
FED 416-422,453-499
(2) Test
(a) Test operation of BULK cargo compartment isolationvalve 19HN, extraction fan 30HN, and FANS MONITORMFA 8HN.
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO temperature selector switch 14HNis in MAN position.
- BULK CARGO/ISOL VALVE pushbutton switch 6HNis released OFF.
On maintenance panel 472VU:
- ANN LT toggle switch 2WB is in READposition.
2) Perform test.
(2)FED 401-405,407-414,423-436,443,445-452
Test
NOTE : Following tests apply for both FWD and BULKcargo compartments.Component FINs for FWD compartment are shownin brackets.
(a) Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), extraction fan 30HN(48HN), and FANS MONITOR MFA 8HN (57HN).
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) isreleased OFF.
On maintenance panel 472VU:
- ANN LT toggle switch 2WB is in READposition.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 4 of 106JUN 01/2012
2) Perform test.
FED 416-422,453-499 --------------------------------------------------------------------------------
ACTION RESULT
--------------------------------------------------------------------------------
1. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- press BULK CARGO/ISOL VALVE - OFF/R legend goes off.
pushbutton switch 6HN. - for duration of isolation valve
flap movement, ISOL VALVE push-
button switch FAULT legend
comes on and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens,
- isolation valve color : green.
On maintenance panel 472VU:
- check that BULK/CARGO MFA does not
come on.
- rotate and hold BULK CARGO temp On R ECAM display - AIR COND page:
selector switch 14HN in MAN-HOT - trim air valve flap position arrow
position until trim air valve flap remains stationary.
position arrow, on R ECAM display -
AIR COND page, is between H and C,
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 5 of 106JUN 01/2012
then release selector switch.
2. On circuit breaker panel 125VU:
- at location G62 open circuit - trim air valve flap position arrow
breaker 37HN. moves to C.
On maintenance panel 472VU:
- BULK/CARGO MFA comes on.
- close circuit breaker 37HN. - BULK/CARGO MFA remains on.
3. On maintenance panel 472VU:
- press MFA RESET pushbutton - BULK/CARGO MFA goes off.
switch 20WB.
4. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- release BULK CARGO/ISOL VALVE - OFF/R legend comes on.
pushbutton switch 6HN. - for duration of isolation valve
flap movement, ISOL VALVE push-
button switch FAULT legend comes
on and then goes off.
On R ECAM display - AIR COND page:
- isolation valve closed,
- isolation valve color : amber.
On maintenance panel 472VU:
- check that BULK/CARGO MFA does
not come on.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 6 of 106JUN 01/2012
FED 401-405,407-414,423-436,443,445-452 1. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- press BULK CARGO/ISOL VALVE - OFF/R legend goes off.
(FWD GARGO/ISOL VALVE)push- - for duration of isolation valve
button switch 6HN (52HN). movement, ISOL VALVE pushbutton
switch FAULT legend comes on and
then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens,
- isolation valve color : green.
On maintenance panel 472VU:
- check that BULK/CARGO (FWD/CARGO)
MFA does not come on.
- rotate and hold BULK CARGO On R ECAM display - AIR COND page:
(FWD CARGO) temperature selector - trim air valve flap position arrow
switch 14HN (53HN) in MAN-HOT remains stationary.
position until trim air valve
flap position arrow, on R ECAM
display - AIR COND page, is be-
tween H and C, then release
selector switch.
2. On circuit breaker panel 125VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 7 of 106JUN 01/2012
- at location G62 open circuit - trim air valve flap position arrow
breaker 37HN moves to C.
- (at location G65 open circuit
breaker 41HN).
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA comes
on.
- close circuit breaker 37HN (41HN). - BULK/CARGO (FWD/CARGO) MFA remains
on.
3. On maintenance panel 472VU:
- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes
switch 20WB. off.
4. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- release BULK CARGO/ISOL VALVE - OFF/R legend comes on.
(FWD CARGO/ISOL VALVE) push- - for duration of isolation valve
button switch 6HN (52HN). flap movement, ISOL VALVE push-
button switch FAULT legend comes
on and then goes off.
On R ECAM display - AIR COND page:
- isolation valve closed,
- isolation valve color : amber.
On maintenance panel 472VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 8 of 106JUN 01/2012
- check that BULK/CARGO (FWD/CARGO)
MFA does not come on.
FED 416-422,453-499
(a) Carry out BITE-Test for cargo compartmenttemperature control system.
NOTE : - Test equipment is located in avionicscompartment at equipment rack 91VU.
1) Initial conditions:On COMPT TEMP panel 437VU:
- PACK VALVE 1 and 2 pushbutton switches191HB and 189HB are pressed in.
- BULK CARGO/ISOL VALVE pushbutton switch 6HNis pressed in.
- BULK CARGO temperature selector switch 14HNis in AUTO position.
- HOT AIR SUPPLY pushbutton switch 4HJ ispressed in.
2) Perform test.-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
1. At rack 91VU, on APU and pack temp On APU and pack temp demand
demand controller 37HK: controller 37HK:
- check that electrical power is - light comes on when pressed.
available at APU and pack temp
demand controller by pressing
BITE READY/UNPLUG CABLE AFTER
USE light,
- make certain that BITE SWITCH
is in position 1.
2. On circuit breaker panel 125VU:
- at location H65 open circuit
breaker 5HN.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 9 of 106JUN 01/2012
3. On BULK CARGO compt temp controller 15HN:
- remove BITE connector protective
cap.
- connect test cable of APU
and pack temperature demand
controller 37HK to BITE connector.
4. On circuit breaker panel 125VU: On APU and pack temp demand
controller:
- at location H65 close circuit - BITE READY/UNPLUG CABLE AFTER USE
breaker 5HN. and GO indicator lights come on.
5. On APU and pack temperature demand
controller:
- press NO GO indicator light. - NO GO integral light comes on.
- place BITE SWITCH to positions - for each position selected,
1 thru 12 in sequence, pausing GO indicator light must come on.
at each position until either
GO or NO GO light comes on.
NOTE : A NO GO light shows a failure
in the cargo compartment
temperature control system.
NOTE : Position 1 - Sum of outputs of pack scaling amplifiers is checked.
Position 2 - APU speed demand signal for maximum cooling is checked.
Position 3 - APU speed demand signal for maximum heating is checked.
Position 4 - Bridge power supply is checked.
Position 5 - Amplifier output is checked.
Position 6 - Drives actuator in more heat direction.
Position 7 - Overrides bridge output with signal to produce maximum
cooling output.
Position 8 - Overrides bridge output with signal to produce maximum
heating output.
Position 9 - Overrides bridge output to produce a 'nulled' output.
Position 10 - Output of bridge is checked.
Position 11 - Output of bridge is checked.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 10 of 106JUN 01/2012
Position 12 - Selector output signal is checked.
- return BITE SWITCH to position 1.
6. On circuit breaker panel 125VU: On APU and pack temperature demand
controller:
- at location H65 open circuit - BITE READY/UNPLUG CABLE AFTER USE
breaker 5HN. and GO indicator lights go off.
7. On BULK CARGO compt temp controller:
- disconnect test cable and secure
to dummy connector 103VC.
- secure protective cap.
8. On circuit breaker panel 125VU:
- at location H65 close circuit
breaker 5HN.
FED 431-436,451-452
(b) Carry out BITE-Test for cargo compartmenttemperature control system.
NOTE : Test equipment is located in avionicscompartment at equipment rack 91VU.
1) Initial conditions:On COMPT TEMP panel 437VU:
- PACK VALVE 1 and 2 pushbutton switches191HB and 189HB are pressed in.
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in AUTO position.
- HOT AIR SUPPLY pushbutton switch 4HJ ispressed in.
2) Perform test.-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
1. At rack 91VU, on APU and pack temp On APU and pack temp demand
demand controller 37HK: controller 37HK:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 11 of 106JUN 01/2012
- check that electrical power is - light comes on when pressed.
available at APU and pack temp
demand controller by pressing
BITE READY/UNPLUG CABLE AFTER
USE light.
- make certain that BITE SWITCH
is in position 1.
2. On circuit breaker panel 125VU:
- at location H65 open circuit
breaker 5HN.
- (at location H63 open circuit
breaker 43HN).
3. On BULK CARGO (FWD CARGO) compt
temp controller 15HN (54HN):
- remove BITE connector cap.
- connect test cable of APU
and pack temperature demand
controller 37HK to BITE connector.
4. On circuit breaker panel 125VU: On APU and pack temp demand
controller:
- at location H65 close circuit - BITE READY/UNPLUG CABLE AFTER
breaker 5HN. USE and GO indicator lights come
- (at location H63 close circuit on.
breaker 43HN).
5. On APU and pack temperature demand
controller:
- press NO GO indicator light. - NO GO integral light comes on.
- place BITE SWITCH to positions - for each position selected,
1 thru 12 in sequence, pausing GO indicator light must come on.
at each position until either
GO or NO GO light comes on.
NOTE : A NO GO light shows a failure
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 12 of 106JUN 01/2012
in the cargo compartment
temperature control system.
NOTE : Position 1 - Sum of outputs of pack scaling amplifiers is checked.
Position 2 - APU speed demand signal for maximum cooling is checked.
Position 3 - APU speed demand signal for maximum heating is checked.
Position 4 - Bridge power supply is checked.
Position 5 - Amplifier output is checked.
Position 6 - Drives actuator in more heat direction.
Position 7 - Overrides bridge output with signal to produce maximum
cooling output.
Position 8 - Overrides bridge output with signal to produce maximum
heating output.
Position 9 - Overrides bridge output to produce a 'nulled' output.
Position 10 - Output of bridge is checked.
Position 11 - Output of bridge is checked.
Position 12 - Selector output signal is checked.
- return BITE SWITCH to position 1.
6. On circuit breaker panel 125VU: On APU and pack temperature demand
controller:
- at location H65 open circuit - BITE READY/UNPLUG CABLE AFTER
breaker 5HN. USE and GO indicator lights go off.
- (at location H63 open circuit
breaker 43HN).
7. On BULK CARGO (FWD CARGO) compt
temp controller:
- disconnect test cable and secure
to dummy connector 103VC.
- Secure protective cap.
8. On circuit breaker panel 125VU:
- at location H65 close circuit
breaker 5HN.
- (at location H63 close circuit
breaker 43HN).
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 13 of 106JUN 01/2012
(b)FED 401-405,407-414,423-430,443,445-450
Carry out BITE-Test for cargo compartmenttemperature control system.
NOTE : Test equipment is located in avionicscompartment at equipment rack 91VU.
1) Initial conditions:On COMPT TEMP panel 437VU:
- PACK VALVE 1 and 2 pushbutton switches191HB and 189HB are pressed in.
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in AUTO position.
- HOT AIR SUPPLY pushbutton switch 4HJ ispressed in.
2) Perform test.-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
1. At rack 91VU, on APU and pack temp On APU and pack temp demand
demand controller 37HK: controller 37HK:
- check that electrical power is - light comes on when pressed.
available at APU and pack temp
demand controller by pressing
BITE READY/UNPLUG CABLE AFTER
USE light.
- make certain that BITE SWITCH
is in position 1.
2. On circuit breaker panel 125VU:
- at location H65 open circuit
breaker 5HN.
- (at location H63 open circuit
breaker 43HN).
3. On BULK CARGO (FWD CARGO) compt
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 14 of 106JUN 01/2012
temp controller 15HN (54HN):
- remove BITE connector cap.
- connect test cable of APU
and pack temperature demand
controller 37HK to BITE connector.
4. On circuit breaker panel 125VU: On APU and pack temp demand
controller:
- at location H65 close circuit - BITE READY/UNPLUG CABLE AFTER
breaker 5HN. USE and GO indicator lights come
- (at location H63 close circuit on.
breaker 43HN).
5. On APU and pack temperature demand
controller:
- press NO GO indicator light. - NO GO integral light comes on.
- place BITE SWITCH to positions - for each position selected,
1 thru 12 in sequence, pausing GO indicator light must come on.
at each position until either
GO or NO GO light comes on.
NOTE : A NO GO light shows a failure
in the cargo compartment
temperature control system.
NOTE : Position 1 - Sum of outputs of pack scaling amplifiers is checked.
Position 2 - APU speed demand signal for maximum cooling is checked.
Position 3 - APU speed demand signal for maximum heating is checked.
Position 4 - Bridge power supply is checked.
Position 5 - Amplifier output is checked.
Position 6 - Drives actuator in more heat direction.
Position 7 - Overrides bridge output with signal to produce maximum
cooling output.
Position 8 - Overrides bridge output with signal to produce maximum
heating output.
Position 9 - Overrides bridge output to produce a 'nulled' output.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 15 of 106JUN 01/2012
Position 10 - Output of bridge is checked.
Position 11 - Output of bridge is checked.
Position 12 - Selector output signal is checked.
- return BITE SWITCH to position 1.
6. On circuit breaker panel 125VU: On APU and pack temperature demand
controller:
- at location H65 open circuit - BITE READY/UNPLUG CABLE AFTER
breaker 5HN. USE and GO indicator lights go off.
- (at location H63 open circuit
breaker 43HN).
7. On BULK CARGO (FWD CARGO) compt
temp controller:
- disconnect test cable and secure
to dummy connector 103VC.
- Secure protective cap.
8. On circuit breaker panel 125VU:
- at location H65 close circuit
breaker 5HN.
- (at location H63 close circuit
breaker 43HN).
(c) Test operation of cold trim air valve 81HN (69HN).
1) Initial conditions:ON COMPT TEMP panel 437VU:
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.
2) Perform test.--------------------------------------------------------------------------------
ACTION RESULT
--------------------------------------------------------------------------------
1. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate and hold BULK CARGO - hot trim air valve flap position
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 16 of 106JUN 01/2012
(FWD CARGO) temp selector arrow remains stationary.
switch 14HN (53HN) in MAN-HOT
position until hot trim air valve
flap position arrow on R ECAM
display - AIR COND page is between
H and C, then release selector switch.
2. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow with scale appears.
3. ON COMPT TEMP panel 437VU:
- rotate and hold BULK CARGO - hot trim air valve flap position
(FWD CARGO) temp selector arrow moves to C, then cold trim
switch 14HN (53HN) in air valve flap position arrow
MAN-COLD position. moves to open position.
- release BULK CARGO (FWD CARGO) - both trim air valve flap position
temp selector switch 14HN (53HN). arrows remain stationary.
4. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold air valve flap position
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 17 of 106JUN 01/2012
arrow and scale disappear.
5. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- after approx. 30 seconds, check - FAULT legend must not come on.
FAULT legend of BULK (FWD) push-
button switch 80HN (78HN).
6. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate and hold BULK CARGO - hot trim air valve flap position
(FWD CARGO) temp selector switch arrow moves to H.
14HN (53HN) in MAN-HOT position.
- release BULK CARGO (FWD CARGO) - trim air valve flap position
temp selector switch. arrow remains stationary.
FED 416-422,431-436,451-499
(b) Not applicable.
FED 416-419
(c) Test operation of BULK cargo compartment isolationvalve 19HN, trim air valve 20HN and extraction fan30HN when SMOKE warning is simulated.
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO temperature selector switch 14HNis in MAN position.
- BULK CARGO/ISOL VALVE pushbutton switch 6HNis pressed in.
On maintenance panel 472VU:
- ANN LT toggle switch 2WB is in READposition.
2) Perform test.
(c)FED 421-422,453-499
Test operation of BULK cargo compartment isolationvalve 19HN, trim air valve 20HN and extraction fan30HN when SMOKE warning is simulated.
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO temperature selector switch 14HNis in MAN position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 18 of 106JUN 01/2012
- BULK CARGO/ISOL VALVE pushbutton switch 6HNis pressed in.
On maintenance panel 472VU:
- ANN LT toggle switch 2WB is in READposition.
On CARGO COMPT SMOKE DET panel 433VU:
- AFT/LOOP A 23WH, AFT/LOOP B 24WH, BULK/LOOPA 25WH and BULK /LOOP B 26WH pushbuttonswitches are pressed in.
2) Perform test.
FED 431-436,451-452
(d) Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), trim air valve 20HN(61HN) and extraction fan 30HN (48HN) when SMOKEwarning is simulated.
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.
On maintenance panel 472VU:
- ANN LT toggle switch 2WB is in READposition.
2) Perform test.
FED 401-405,407-414
(d) Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), hot trim air valve20HN (61HN), cold trim air valve 81HN (69HN) andextraction fan 30HN (48HN) when SMOKE warning issimulated.
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position .
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.
On maintenance panel 472VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 19 of 106JUN 01/2012
- ANN LT toggle switch 2WB is in READposition.
2) Perform test.
(d)FED 423-430,443,445-450
Test operation of BULK (FWD) cargo compartmentisolation valve 19HN (60HN), hot trim air valve20HN (61HN), cold trim air valve 81HN (69HN) andextraction fan 30HN (48HN) when SMOKE warning issimulated.
1) Initial conditions:On COMPT TEMP panel 437VU:
- BULK CARGO (FWD CARGO) temperature selectorswitch 14HN (53HN) is in MAN position.
- BULK CARGO/ISOL VALVE (FWD CARGO/ISOLVALVE) pushbutton switch 6HN (52HN) ispressed in.
On maintenance panel 472VU:
- ANN LT toggle switch 2WB is in READposition.
On CARGO COMPT SMOKE DET panel 433VU:
- FWD/LOOP A (21WH), FWD/LOOP B (22WH), AFT/LOOP A 23WH, AFT/LOOP B
- 24WH, BULK/LOOP A 25WH and BULK/LOOP B 26WHpushbutton switches are pressed in.
2) Perform test.
FED 453-499
--------------------------------------------------------------------------------
ACTION RESULT
--------------------------------------------------------------------------------
1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE
DET panel 433VU: DET panel 433VU:
- release BULK/LOOP B push- - OFF legend comes on.
button switch 26WH. On WLDP:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 20 of 106JUN 01/2012
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate and hold BULK CARGO - trim air valve opens fully and flap
temp selector switch 14HN in position arrow remains stationary
MAN-HOT position until trim at H.
air valve flap position arrow,
on R ECAM display - AIR COND
page, is at H, then release
selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton
selector switch 16WA to CARGO switch 52WA comes on.
COMPT/BULK position.
- place CARGO COMPT/LOOP TEST SEL
toggle switch 48WH to LOOP A
position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 21 of 106JUN 01/2012
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT pushbutton - BULK/SMOKE red warning light 12WH
switch 52WA. and LOOP A legend 25WH come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
ISOL VALVE pushbutton switch 6HN
FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and color
changes to amber.
- trim air valve flap position arrow
moves to position C.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 22 of 106JUN 01/2012
- BULK/SMOKE warning light and LOOP
A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
pushbutton switch 6HN. ISOL VALVE pushbutton switch
FAULT legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- trim air valve flap position arrow
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 23 of 106JUN 01/2012
remains at position C.
6. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend of PTT pushbutton
selector switch 16WA to NORM/FLT switch 52WA goes off.
position.
7. On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel
panel 433VU: 433VU:
- press BULK/LOOP B pushbutton - OFF legend goes off.
switch 26WH. On WLDP:
- LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
disappears.
FED 453-454,456-499
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 24 of 106JUN 01/2012
1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE
DET panel 433VU: DET panel 433VU:
- release BULK/LOOP B push- - OFF legend comes on.
button switch 26WH. On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate and hold BULK CARGO - trim air valve opens fully and flap
temp selector switch 14HN in position arrow remains stationary
MAN-HOT position until trim at H.
air valve flap position arrow,
on R ECAM display - AIR COND
page, is at H, then release
selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton
selector switch 16WA to CARGO switch 52WA comes on.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 25 of 106JUN 01/2012
COMPT/BULK position.
- place CARGO COMPT/LOOP TEST SEL
toggle switch 48WH to LOOP A
position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT pushbutton - BULK/SMOKE red warning light 12WH
switch 52WA. and LOOP A legend 25WH come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE
pushbutton switch 6HN
FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and color
changes to amber.
- trim air valve flap position arrow
moves to position C.
On L ECAM display:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 26 of 106JUN 01/2012
SMOKE
BULK CARGO COMPT SMOKE
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE warning light and LOOP
A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 27 of 106JUN 01/2012
pushbutton switch 6HN. ISOL VALVE pushbutton switch
FAULT legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- trim air valve flap position arrow
remains at position C.
6. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend of PTT pushbutton
selector switch 16WA to NORM/FLT switch 52WA goes off.
position.
7. On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel
panel 433VU: 433VU:
- press BULK/LOOP B pushbutton - OFF legend goes off.
switch 26WH. On WLDP:
- LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
disappears.
FED 416-436,443,445,451-499POST SB 31-2035 for A/C 423-435,443,445,453-499POST SB 31-2059 for A/C 423-430,443,445
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 28 of 106JUN 01/2012
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),
the ECAM SMOKE WARNING will include LAND ASAP for second priority of the
advisory.
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 29 of 106JUN 01/2012
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened,
then release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA comes on.
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
25WH (21WH) legend come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 30 of 106JUN 01/2012
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE
(FWD CARGO/ISOL VALVE) push-
button switch 6HN (52HN)
FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes
and color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On WLDP:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 31 of 106JUN 01/2012
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - after isolation valve opens
VALVE (FWD CARGO/ISOL ISOL VALVE pushbutton switch FAULT
VALVE) pushbutton switch legend goes off.
6HN (52HN). On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 32 of 106JUN 01/2012
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap
position arrow with scale appears.
7. On COMPT TEMP panel 437VU:
- rotate and hold BULK - hot trim air valve flap position
CARGO (FWD CARGO) temp arrow remains at C and cold
selector switch 14HN (53HN) trim air valve flap position
in MAN-COLD position. arrow moves to position C.
- release BULK CARGO (FWD - cold trim air valve flap
CARGO) temp selector switch position arrow remains
14HN (53HN) when cold trim stationary.
air valve is approx. half opened.
8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 33 of 106JUN 01/2012
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD CARGO/
ISOL VALVE) pushbutton switch 6HN
(52HN) FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On WLDP:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 34 of 106JUN 01/2012
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT
button switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
10. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 35 of 106JUN 01/2012
to NORM/FLT position.
11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On WLDP:
26WH (22WH). - LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF)
disappears.
12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
*Before SB 31-2035
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 36 of 106JUN 01/2012
*Before SB 31-2041
*Before SB 31-2059
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened,
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 37 of 106JUN 01/2012
then release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA comes on.
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
25WH (21WH) legend come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE
(FWD CARGO/ISOL VALVE) push-
button switch 6HN (52HN)
FAULT legend comes on.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 38 of 106JUN 01/2012
On R ECAM display - AIR COND page:
- isolation valve closes
and color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 39 of 106JUN 01/2012
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - after isolation valve opens
VALVE (FWD CARGO/ISOL ISOL VALVE pushbutton switch FAULT
VALVE) pushbutton switch legend goes off.
6HN (52HN). On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 40 of 106JUN 01/2012
On R ECAM display - AIR COND page:
- cold trim air valve flap
position arrow with scale appears.
7. On COMPT TEMP panel 437VU:
- rotate and hold BULK - hot trim air valve flap position
CARGO (FWD CARGO) temp arrow remains at C and cold
selector switch 14HN (53HN) trim air valve flap position
in MAN-COLD position. arrow moves to position C.
- release BULK CARGO (FWD - cold trim air valve flap
CARGO) temp selector switch position arrow remains
14HN (53HN) when cold trim stationary.
air valve is approx. half opened.
8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD CARGO/
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 41 of 106JUN 01/2012
ISOL VALVE) pushbutton switch 6HN
(52HN) FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 42 of 106JUN 01/2012
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT
button switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
10. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 43 of 106JUN 01/2012
11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On WLDP:
26WH (22WH). - LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF)
disappears.
12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
FED 423-430,443,445PRE SB 21-2015 for A/C 423-430,443,445PRE SB 31-2023 for A/C 423-430,443,445PRE SB 31-2035 for A/C 423-430,443,445
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 44 of 106JUN 01/2012
433VU: 433VU:
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF.
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened,
then release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 45 of 106JUN 01/2012
COMPT selector switch 16WA switch 52WA comes on.
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
25WH (21WH) legend come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- for duration of isolation valve
flap movement, BULK CARGO/ISOL
VALVE (FWD CARGO/ISOL VALVE)
pushbutton switch 6HN (52HN)
FAULT legend comes on and then
goes off.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 46 of 106JUN 01/2012
On R ECAM display - AIR COND page:
- isolation valve closes
and color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA
8HN (57HN) comes on.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 47 of 106JUN 01/2012
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - for duration of isolation valve
VALVE (FWD CARGO/ISOL flap movement, ISOL VALVE push-
VALVE) pushbutton switch button switch FAULT legend comes on
6HN (52HN). and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) remains on.
6. On maintenance panel 472VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 48 of 106JUN 01/2012
- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes
switch 20WB. off and remains off.
7. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
8OHN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap
position arrow with scale appears.
8. On COMPT TEMP panel 437VU:
- rotate to and hold BULK - hot trim air valve flap position
CARGO (FWD CARGO) temp arrow remains at C and cold
selector switch 14HN trim air valve flap position
(53HN) in MAN-COLD posi- arrow moves to position C.
tion.
- release BULK CARGO (FWD - cold trim air valve flap
CARGO) temp selector switch position arrow remains
14HN (53HN) when cold trim stationary.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 49 of 106JUN 01/2012
air valve is approx. half opened.
9. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- for duration of isolation valve
flap movement, BULK CARGO/ISOL
VALVE (FWD CARGO/ISOL VALVE)
pushbutton switch 6HN (52HN)
FAULT legend comes on and
then goes off.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 50 of 106JUN 01/2012
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA
8HN (57HN) comes on.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 51 of 106JUN 01/2012
- LDG ELEVATION - 10,000 FT
disappears.
10. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - for duration of isolation valve
(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-
button switch 6HN (52HN). button switch FAULT legend comes on
and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
11. On maintenance panel 472VU: On maintenance panel 472VU:
- press MFA RESET push- - BULK/CARGO (FWD/CARGO) MFA
button switch 20WB. goes off.
12. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 52 of 106JUN 01/2012
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On WLDP:
26WH (22WH). - LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF
disappears.
14. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 8OHN (78HN). On L ECAM display:
- BULK CARGO COOLING ON
- (FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
** Before SB 21-2015
** Post SB 31-2023 For A/C 001-009, 501-501, 551-551
** Post SB 31-2035 For A/C 001-009, 501-501, 551-551
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 53 of 106JUN 01/2012
433VU: 433VU:
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened,
then release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 54 of 106JUN 01/2012
COMPT selector switch 16WA switch 52WA comes on.
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
25WH (21WH) legend come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- for duration of isolation valve
flap movement, BULK CARGO/ ISOL
VALVE (FWD CARGO/ISOL VALVE)
pushbutton switch 6HN (52HN)
legend comes on and then goes
off.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 55 of 106JUN 01/2012
On R ECAM display - AIR COND page:
- isolation valve closes
and color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA
8HN (57HN) comes on.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 56 of 106JUN 01/2012
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - for duration of isolation valve
VALVE (FWD CARGO/ISOL flap movement, ISOL VALVE push-
VALVE) pushbutton switch button switch FAULT legend comes on
6HN (52HN). and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) remains on.
6. On maintenance panel 472VU:
- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA goes
switch 20WB. off and remains off.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 57 of 106JUN 01/2012
7. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap
position arrow with scale appears.
8. On COMPT TEMP panel 437VU:
- rotate to and hold BULK - hot trim air valve flap position
CARGO (FWD CARGO) temp arrow remains at C and cold
selector switch 14HN trim air valve flap position
(53HN) in MAN-COLD posi- arrow moves to position C.
tion.
- release BULK CARGO (FWD - cold trim air valve flap
CARGO) temp selector switch position arrow remains
14HN (53HN) when cold trim stationary.
air valve is approx. half opened.
9. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 58 of 106JUN 01/2012
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- for duration of isolation valve
flap movement, BULK CARGO/ISOL
VALVE (FWD CARGO/ISOL VALVE)
pushbutton switch 6HN (52HN)
FAULT legend comes on and
then goes off.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 59 of 106JUN 01/2012
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA
8HN (57HN) comes on.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
10. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - for duration of isolation valve
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 60 of 106JUN 01/2012
(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-
button switch 6HN (52HN). button switch FAULT legend comes on
and then goes off.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) remains on.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
11. On maintenance panel 472VU: On maintenance panel 472VU:
- press MFA RESET push- - BULK/CARGO (FWD/CARGO) MFA
button switch 20WB. goes off.
12. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
13. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 61 of 106JUN 01/2012
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On WLDP:
26WH (22WH). - LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF
disappears.
14. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
- BULK CARGO COOLING ON
- (FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
** Before SB 31-2023
** Before SB 31-2035
** Post SB 21-2015 For A/C 001-001, 003-003, 008-009, 551-551
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 62 of 106JUN 01/2012
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened,
then release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA comes on.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 63 of 106JUN 01/2012
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
25WH (21WH) legend come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE
(FWD CARGO/ISOL VALVE) push-
button switch 6HN (52HN) FAULT
legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes
and color changes to amber.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 64 of 106JUN 01/2012
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 65 of 106JUN 01/2012
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - after isolation valve opens
VALVE (FWD CARGO/ISOL ISOL VALVE pushbutton switch FAULT
VALVE) pushbutton switch legend goes off.
6HN (52HN). On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
8OHN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap
position arrow with scale appears.
7. On COMPT TEMP panel 437VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 66 of 106JUN 01/2012
- rotate and hold BULK - hot trim air valve flap position
CARGO (FWD CARGO) temp arrow remains at C and cold
selector switch 14HN (53HN) trim air valve flap position
in MAN-COLD position. arrow moves to position C.
- release BULK CARGO (FWD - cold trim air valve flap
CARGO) temp selector switch position arrow remains
14HN (53HN) when cold trim stationary.
air valve is approx. half opened.
8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA. warning light 12WH (1WH) and LOOP A
legend 25WH (21WH) come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD CARGO/
ISOL VALVE) pushbutton switch 6HN
(52HN) FAULT legend comes on.
On R ECAM display - AIR COND page:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 67 of 106JUN 01/2012
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 68 of 106JUN 01/2012
(FWD CARGO COMPT SMOKE)
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) push- ISOL VALVE pushbutton switch FAULT
button switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
10. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On WLDP:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 69 of 106JUN 01/2012
26WH (22WH). - LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF)
disappears.
12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 8OHN (78HN). On L ECAM display:
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
FED 446,450POST SB 31-2035 for A/C 446,450
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On main instrument panels 3VU
and 5VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 70 of 106JUN 01/2012
- MASTER/CAUTION lights come on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF.
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened, then
release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA comes on.
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 71 of 106JUN 01/2012
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA: warning light 12WH (1WH) and
LOOP A legend 25WH (21WH) come on.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights flash.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD
CARGO/ISOL VALVE) pushbutton
switch 6HN (52HN) FAULT
legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 72 of 106JUN 01/2012
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights go off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 73 of 106JUN 01/2012
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT
pushbutton switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- hot trim air valve flap position
arrow remains at position C.
6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow with scale appears.
7. On COMPT TEMP panel 437VU:
- rotate and hold BULK CARGO - hot trim air valve flap position
(FWD CARGO) temp selector arrow remains at C and cold
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 74 of 106JUN 01/2012
switch 14HN (53HN) in trim air valve flap position arrow
MAN-COLD position. moves towards position C.
- release BULK CARGO - cold trim air valve flap position
(FWD CARGO) temp selector arrow remains stationary.
switch when cold trim air
valve is approx. half opened.
8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red warning
button switch 52WA. light 12WH (1WH) and LOOP A legend
25WH (21WH) come on.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights flash.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD
CARGO/ISOL VALVE) pushbutton
switch 6HN (52HN) FAULT
legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 75 of 106JUN 01/2012
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights go off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 76 of 106JUN 01/2012
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT
pushbutton switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
10. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On main instrument panels 3VU
26WH (22WH). and 5VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 77 of 106JUN 01/2012
- MASTER/CAUTION lights go off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF)
disappears.
12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
- BULK CARGO COOLING ON
- (FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
FED 447-449POST SB 31-2035 for A/C 447-449
1. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- release BULK/LOOP B (FWD/LOOP B) - OFF legend comes on.
pushbutton switch 26WH (22WH). On main instrument panels 3VU
and 5VU:
- MASTER/CAUTION lights come on.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 78 of 106JUN 01/2012
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
- BULK COMPT LOOP B - OFF.
- (FWD COMPT LOOP B - OFF)
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air valve
flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened, then
release selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA comes on.
to CARGO COMPT/BULK (CARGO
COMPT/FWD/1) position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 79 of 106JUN 01/2012
- place CARGO COMPT/LOOP TEST
SEL toggle switch 48WH to
LOOP A position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red
button switch 52WA: warning light 12WH (1WH) and
LOOP A legend 25WH (21WH) come on.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights flash.
In flight compartment:
-repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD
CARGO/ISOL VALVE) pushbutton
switch 6HN (52HN) FAULT
legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 80 of 106JUN 01/2012
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - BULK/SMOKE (FWD/SMOKE) red
warning light and LOOP A
legend go off.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights go off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 81 of 106JUN 01/2012
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT
pushbutton switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- hot trim air valve flap position
arrow remains at position C.
6. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton switch - ON legend comes on.
80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow with scale appears.
7. On COMPT TEMP panel 437VU:
- rotate and hold BULK CARGO - hot trim air valve flap position
(FWD CARGO) temp selector arrow remains at C and cold
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 82 of 106JUN 01/2012
switch 14HN (53HN) in trim air valve flap position arrow
MAN-COLD position. moves towards position C.
- release BULK CARGO - cold trim air valve flap position
(FWD CARGO) temp selector arrow remains stationary.
switch when cold trim air
valve is approx. half opened.
8. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT push- - BULK/SMOKE (FWD/SMOKE) red warning
button switch 52WA. light 12WH (1WH) and LOOP A legend
25WH (21WH) come on.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights flash.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD
CARGO/ISOL VALVE) pushbutton
switch 6HN (52HN) FAULT
legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 83 of 106JUN 01/2012
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock
(closed) position.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE (FWD/SMOKE) warning
light and LOOP A legend go off.
On main instrument panels 3VU
and 5VU:
- MASTER/WARNING lights go off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 84 of 106JUN 01/2012
- LDG ELEVATION - 10,000 FT
disappears.
9. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT
pushbutton switch 6HN (52HN). legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
10. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - TEST legend of PTT pushbutton
COMPT selector switch 16WA switch 52WA goes off.
to NORM/FLT position.
11. On CARGO COMPT SMOKE DET panel On CARGO COMPT SMOKE DET panel
433VU: 433VU:
- press BULK/LOOP B (FWD/ - OFF legend goes off.
LOOP B) pushbutton switch On main instrument panels 3VU
26WH (22WH). and 5VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 85 of 106JUN 01/2012
- MASTER/CAUTION lights go off.
On L ECAM display:
LOOP
BULK COMPT LOOP B - OFF
(FWD COMPT LOOP B - OFF)
disappears.
12. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
- BULK CARGO COOLING ON
- (FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
FED 401-405,407-412POST SB 31-2059 for A/C 401-405,407-412
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
FED ALL
NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),
the ECAM SMOKE warning will include LAND ASAP for second priority
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 86 of 106JUN 01/2012
of the advisory.
1. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD - hot trim air valve opens and
CARGO) temp selector switch remains stationary, color:
14HN (53HN) to MAN-HOT posi- green.
tion, hold unil hot trim air
valve flap position arrow, on
R ECAM display - AIR COND page,
is at least half opened, then
release selector switch.
2. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA TEST
COMPT selector switch 16WA legend comes on.
to CARGO COMPT/BULK/1
(CARGO COMPT/FWD/1) position.
- press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU,
switch 52WA. after approx. 2-3 second delay:
- AFT & BULK/SMOKE (FWD/SMOKE)
red warning light 38WH (39WH)
comes on.
In flight compartment:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 87 of 106JUN 01/2012
- repetitive chime sounds.
On WLDP:
- SMOKE warning light flashes.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD
CARGO/ISOL VALVE) pushbutton switch
6HN (52HN) FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - AFT & BULK/SMOKE (FWD/SMOKE)
red warning light goes off.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 88 of 106JUN 01/2012
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
disappears.
3. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL - after isolation valve opens, ISOL
VALVE (FWD CARGO/ISOL VALVE pushbutton switch FAULT
VALVE) pushbutton switch legend goes off.
6HN (52HN). On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
4. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton - ON legend comes on.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 89 of 106JUN 01/2012
switch 80HN (78HN) On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow with scale appears.
5. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve flap
temperature selector switch position arrow remains at C and
14HN (53HN) to MAN COLD cold trim air valve flap
position. position arrow moves towards
position C.
- release BULK CARGO (FWD CARGO) - cold trim air valve flap
temp selector switch 14HN position arrow remains stationary.
(53HN) when cold trim air
valve 81HN (69HN) is approx.
half open.
6. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU,
- press and hold PTT pushbutton after approx. 2-3 second delay:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 90 of 106JUN 01/2012
switch 52WA. - AFT & BULK/SMOKE (FWD/SMOKE)
red warning lights 38WH (39WH)
comes on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE (FWD
CARGO/ISOL VALVE) pushbutton switch
6HN (52HN) FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock (closed)
position.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 91 of 106JUN 01/2012
- MAX FL - 100/MEA
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - AFT & BULK/SMOKE (FWD/SMOKE)
warning lights go off.
In flight compartment:
- repetitive chime stops.
On WLDP:
- SMOKE warning light goes off.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
disappears.
7. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
(FWD CARGO/ISOL VALVE) ISOL VALVE pushbutton switch FAULT
pushbutton switch 6HN legend goes off.
(52HN). On R ECAM display - AIR COND page:
- isolation valve opens and
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 92 of 106JUN 01/2012
color changes to green.
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
8. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 80HN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
9. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA TEST
COMPT selector switch 16WA legend goes off.
to NORM/FLT position.
FED 413-414
FED ALL
FED ALL
FED ALL
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 93 of 106JUN 01/2012
FED ALL
FED ALL
FED ALLPOST SB 31-2059 for A/C 413-414
NOTE : Setting the A/C to simulated FLT CONFIG (Ref. 32-00-00, P. Block 501),
the ECAM SMOKE warning will include LAND ASAP for second priority
of the advisory.
1. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve opens and
temp selector switch 14HN remains stationary, color: green.
(53HN) to MAN-HOT position,
hold until hot trim air
valve flap position arrow,
on R ECAM display - AIR COND
page, is at least half opened,
then release selector switch.
2. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA TEST
COMPT selector switch legend comes on.
16WA to CARGO COMPT/BULK/1
(CARGO COMPT/FWD/1) position.
- press and hold PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU,
switch 52WA. after 2-3 second delay:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 94 of 106JUN 01/2012
- AFT & BULK/SMOKE (FWD/SMOKE)
red warning light 38WH (39WH)
comes on.
In flight compartment:
- repetitive chime sounds.
On WLDP:
- SMOKE warning light flashes.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) comes on.
On COMPT TEMP panel 437VU:
- for duration of isolation valve
flap movement, BULK CARGO/ISOL
VALVE (FWD CARGO/ISOL VALVE)
pushbutton switch 6HN (52HN) FAULT
legend comes on and then goes off.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- hot trim air valve flap position
arrow moves to position C.
On L ECAM display:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 95 of 106JUN 01/2012
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
appears.
- release PTT pushbutton On CARGO COMPT SMOKE DET panel 433VU:
switch. - AFT & BULK/SMOKE (FWD/SMOKE)
warning light goes off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
disappears.
3. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - for duration of isolation valve
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 96 of 106JUN 01/2012
(FWD CARGO/ISOL VALVE) push- flap movement, ISOL VALVE push-
button switch 6HN (52HN) button switch FAULT legend comes
(release p/b sw and press on and then goes off.
again). On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) remains on.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
- hot trim air valve flap position
arrow remains at position C.
4. On maintenance panel 472VU: On maintenance panel 472VU:
- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA
switch 20WB. goes off.
5. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- press BULK (FWD) pushbutton - ON legend comes on.
switch 8OHN (78HN). On L ECAM display:
MEMO
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
appears.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 97 of 106JUN 01/2012
On R ECAM display - AIR COND page:
- cold trim air valve flap
position arrow with scale appears.
6. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate BULK CARGO (FWD CARGO) - hot trim air valve flap position
temperature selector switch arrow remains at C and cold
14HN (53HN) to MAN-COLD trim air valve flap position
position and hold. arrow moves to position C.
- release BULK CARGO (FWD CARGO) - cold trim air valve flap
temperature selector switch position arrow remains
14HN (53HN) when cold trim stationary.
air valve is approx. half open.
7. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU,
- press and hold PTT pushbutton after approx. 2-3 second delay:
switch 52WA. - AFT & BULK/SMOKE (FWD/SMOKE)
red warning light 38WH (39WH)
comes on.
In flight compartment:
- repetitive chime sounds.
On WLDP:
- SMOKE warning light flashes.
On COMPT TEMP panel 437VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 98 of 106JUN 01/2012
- for duration of isolation valve
flap movement, ISOL VALVE
pushbutton switch 6HN (52HN)
FAULT legend comes on and then
goes off.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA
8HN (57HN) comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and
color changes to amber.
- cold trim air valve flap position
arrow moves to 10 o'clock (closed)
position.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
appears.
- release PTT pushbutton On CARGO COMP SMOKE DET panel 433VU:
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 99 of 106JUN 01/2012
switch. - AFT & BULK/SMOKE (FWD/SMOKE)
red warning light goes off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
AFT & BULK CARGO COMPT SMOKE
(FWD CARGO COMPT SMOKE)
- LDG ELEVATION - 10,000 FT
- MAX FL - 100/MEA
disappears.
8. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - for duration of isolation valve
(FWD CARGO/ISOL VALVE) flap movement, ISOL VALVE push-
pushbutton switch 6HN (52HN). button switch FAULT legend comes
on and then goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and
color changes to green.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 100 of 106JUN 01/2012
- cold trim air valve flap position
arrow remains at 10 o'clock
(closed) position.
On maintenance panel 472VU:
- BULK/CARGO (FWD/CARGO) MFA 8HN
(57HN) remains on.
9. On maintenance panel 472VU:
- press MFA RESET pushbutton - BULK/CARGO (FWD/CARGO) MFA
switch 20WB. goes off.
10. On CARGO COOL panel 444VU: On CARGO COOL panel 444VU:
- release BULK (FWD) pushbutton - ON legend goes off.
switch 8OHN (78HN). On L ECAM display:
BULK CARGO COOLING ON
(FWD CARGO COOLING ON)
disappears.
On R ECAM display - AIR COND page:
- cold trim air valve flap position
arrow and scale disappear.
11. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO - PTT pushbutton switch 52WA
COMPT selector switch TEST legend goes off.
16WA to NORM/FLT position.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 101 of 106JUN 01/2012
FED 453-499POST SB 31-2035 for A/C 453-499
1. On CARGO COMPT SMOKE On CARGO COMPT SMOKE
DET panel 433VU: DET panel 433VU:
- release BULK/LOOP B push- - OFF legend comes on.
button switch 26WH. On WLDP:
- LOOP warning light comes on.
In flight compartment:
- single chime sounds.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
appears.
2. On COMPT TEMP panel 437VU: On R ECAM display - AIR COND page:
- rotate and hold BULK CARGO - trim air valve opens fully and flap
temp selector switch 14HN in position arrow remains stationary
MAN-HOT position until trim at H.
air valve flap position arrow,
on R ECAM display - AIR COND
page, is at H, then release
selector switch.
3. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend off PTT pushbutton
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 102 of 106JUN 01/2012
selector switch 16WA to CARGO switch 52WA comes on.
COMPT/BULK position.
- place CARGO COMPT/LOOP TEST SEL
toggle switch 48WH to LOOP A
position.
4. On maintenance panel 471VU: On CARGO COMPT SMOKE DET panel 433VU:
- press and hold PTT pushbutton - BULK/SMOKE red warning light 12WH
switch 52WA. and LOOP A legend 25WH come on.
On WLDP:
- SMOKE warning light flashes.
In flight compartment:
- repetitive chime sounds.
On COMPT TEMP panel 437VU:
- BULK CARGO/ISOL VALVE
pushbutton switch 6HN
FAULT legend comes on.
On R ECAM display - AIR COND page:
- isolation valve closes and color
changes to amber.
- trim air valve flap position arrow
moves to position C.
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 103 of 106JUN 01/2012
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
appears.
- release PTT pushbutton switch. On CARGO COMPT SMOKE DET panel 433VU:
- BULK/SMOKE warning light and LOOP
A legend go off.
On WLDP:
- SMOKE warning light goes off.
In flight compartment:
- repetitive chime stops.
On L ECAM display:
SMOKE
BULK CARGO COMPT SMOKE
- AGENT 1 - DISCH
- LDG ELEVATION - 10,000 FT
disappears.
5. On COMPT TEMP panel 437VU: On COMPT TEMP panel 437VU:
- reset BULK CARGO/ISOL VALVE - after isolation valve opens,
pushbutton switch 6HN. ISOL VALVE pushbutton switch
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 104 of 106JUN 01/2012
FAULT legend goes off.
On R ECAM display - AIR COND page:
- isolation valve opens and color
changes to green.
- trim air valve flap position arrow
remains at position C.
6. On maintenance panel 471VU: On maintenance panel 471VU:
- rotate ELEC COMPT & CARGO COMPT - TEST legend of PTT pushbutton
selector switch 16WA to NORM/FLT switch 52WA goes off.
position.
7. On CARGO COMPT SMOKE DET On CARGO COMPT SMOKE DET panel
panel 433VU: 433VU:
- press BULK/LOOP B pushbutton - OFF legend goes off.
switch 26WH. On WLDP:
- LOOP warning light goes off.
On L ECAM display:
LOOP
BULK COMPT LOOP B OFF
disappears.
FED 416-422,453-499
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 105 of 106JUN 01/2012
(3) Close-Up
(a) On maintenance panel 472VU, place ANN LT toggleswitch 2WB in OFF position.
(b) On ECAM control panel, release ECAM SGU 1 and 2pushbutton switches.
(c) On COMPT TEMP panel 437VU, rotate BULK CARGOtemperature selector switch 14HN to AUTO position.
(d) Make certain that working area is clean and clearof tools and miscellaneous items of equipment.
(e) De-energize aircraft electrical network anddisconnect electrical ground power unit (Ref.24-41-00, P. Block 301 ) .
(3)FED 401-405,407-414,423-436,443,445-452
Close-Up
(a) On maintenance panel 472VU, place ANN LT toggleswitch 2WB in OFF position.
(b) On ECAM control panel, release ECAM SGU 1 and 2pushbutton switches.
(c) On COMPT TEMP panel 437VU, rotate BULK CARGO (FWDCARGO) temperature selector switch 14HN (53HN) toAUTO position.
(d) Make certain that working area is clean and clearof tools and miscellaneous items of equipment.
(e) De-energize aircraft electrical network anddisconnect electrical ground power unit (Ref.24-41-00, P. Block 301 ) .
A310-200 AMM - CARGO COMPARTMENTTEMPERATURE CONTROL - ADJUSTMENT/TESTRevision 32.0
P.Blk EFFECTIVITY: FED ALL 21-64-00-05Printed - Date: 12/11/12 Time:Copyright © 12 FedEx Express Corporation, Memphis TN, 38194, All rights reserved.
Page 106 of 106JUN 01/2012