A400M MRO Hanger RAF Brize Norton Type of System: Stormwater Attenuation Date of installation: July 2014 Tank size: ASP Tank 4697m A400M Tank 3542m 3 Site Problem: A RAF base in Brize Norton required two big tank to accommodate 8239m of surface water airplanes. A solution was needed to help alleviate flood risks around the site that would allow traffic to continue moving during heavy storm events and prevent flood damage to surrounding properties. Project/ ClientRequirements : The tank was to be located beneath a heavily trafficked area by HGV vehicles and airplanes with a high water table (Very close to the ground level). A solution had to be found that would accomodate these requirements. This meant that on top of dealing with the usual stormwater requirements, there was also need to consider structural loading from the surrounding road traffic. Furthermore the scheme was to be adopted by Kelda Water and the roads had to be compliant with highway authority requirements who had specified requirements for inspection and maintenance access points as well as various other requirements for Environmental Sustainable Solutions Ltd Sladen Mill, Halifax Road, Littleborough, Lancashire, OL15 0LB Tel: +44 (0) 1706 374416 Fax: +44 (0) 1706 376785 Email: [email protected] Web: www.y-ess.com Registered in England No. 03115064 Registered Of ce 3 3 to be installed in a deep excavation with high water table, and aheavily trafficked area above by HGV vehicles and the supply of appropriate test data. Access to the then current Note:- Kelda Water are responsible for the maintenance of the surface water infrastructure on the site. tanks (tubular) proving problematic, based on "confined space entry regulations.

A400M MRO Hanger RAF Brize Norton - Alderburghalderburgh.com/sites/default/files/pdf/case-studies/A400M MRO... · A400M MRO Hanger RAF Brize Norton Type of System: Stormwater Attenuation

Embed Size (px)

Citation preview

A400M MRO Hanger RAF Br ize Nor ton

Type o f Sys tem: S to rmwate r A t tenua t ion

Date o f i ns ta l l a t i on : Ju l y 2014

Tank s i ze : ASP Tank 4697m A400M Tank 3542m

3

S i te P rob lem:

A RAF base in B r i ze Nor ton requ i red two b ig

tank to accommodate 8239m o f su r face wa te r

airplanes. A so lu t ion was needed to he lp a l l ev ia te

f l ood r i sks a round the s i te tha t wou ld a l l ow t ra f f i c

t o con t inue mov ing du r ing heavy s to rm even ts and

p reven t f l ood damage to su r round ing p rope r t i es .

P ro jec t/ C l ien tRequ i rements :

The tank was to be loca ted benea th a heavily

trafficked area by HGV vehicles and airplanes wi th

a high water table (Very close to the ground level).

A so lu t i on had to be found tha t wou ld accomoda te

these requ i remen ts . Th is mean t tha t on top o f

dea l ing w i th the usua l s to rmwate r requ i remen ts , the re

was a l so need to cons ide r s t ruc tu ra l l oad ing f rom the

su r round ing road t ra f f i c . Fur thermore the scheme was

to be adop ted by Ke lda Wate r and the roads had to be

comp l ian t w i th h ighway au thor i t y requ i rements who had

spec i f i ed requ i remen ts fo r i nspec t ion and ma in tenance

access po in ts as we l l as va r ious o the r requ i remen ts fo r

Environmental Sustainable Solutions Ltd

Sladen Mill, Halifax Road, Littleborough, Lancashire, OL15 0LB

Tel: +44 (0) 1706 374416Fax: +44 (0) 1706 376785 Email: [email protected]

Web: www.y-ess.com

Registered in England No. 03115064 Registered Of ce

3

3

to be installed in a deep excavation with high water table, and aheavily trafficked area above by HGV vehicles and

the supp ly o f appropr i a te tes t da ta . Access to the then current

No te : - Ke lda Wate r a re respons ib le fo r the ma in tenance o f t he su r face wa te r i n f ras t ruc tu re on the s i te .

tanks (tubular) proving problematic, based on "confined space entry regulations.

ESS So lu t i on :

ESS spec i f i ed a modu la r VersaVo id , Pluvial Cube and

Aquadrain tank w i th a vo id ra t io o f 96%, th i s p rov ided 3

approx ima te ly A t 8239m (7909m Nett ) s to rage capac i t y

f o r excess s to rmwate r runo f f f rom the s i te .

The 320kN/m 2 & 400kN/m load ing s t reng th p rov ided

by each modu le gave the tank the requ i red s t ruc tu ra l

s tab i l i t y to cope w i th l oad ing f rom above . The

120kN/m 2& 200kN/m la te ra l s t reng th p rov ided

the same capab i l i t y ho r i zon ta l l y a l l ow ing the tank

to cope w i th any s ide load ing tha t may be

induced f rom t ra f f i c f l ows e i the r s ide o f the tank .

Un l i ke o the r p roposed c ra te sys tems , VersaVo id ’s,

Pluvial’s and Aquadrain modu la r cons t ruc t ion p rov ided

the requ i red f l ex ib i l i t y to accommoda te the heavy

l oads .

O the r add i t i ons inc luded a mass ive number o f

160ø

access /ven t p ipes as we l l as 600mmø inspec t ion

un i t s above the tank ( fo r ma in tenance and inspec t ion ) .

Once ins ta l led , the tank is wrapped in a water t ight , heat -we lded Tuf lex l in ing which is fur ther pro tec ted wi th in a Geotex 300PP Protec t ion F leece . A l l inspect ion chambers and out le ts a re wrapped in pre formed Tuf lex c loaks and heat we lded to the tank l in ing .

3

2

2

A400M MRO HangerRAF Br ize Nor ton

access /ven t

ø access chamber600

Spec ia l Cons ide ra t ions : The 1m w ide P luv ia l Cube a r round the pe r ime te r w i th 4 l aye rs o f Aquadra in 50 / 200mm deep .ASP Tank

Con f igu ra t i on : 4697m /1 .8m & 1.075m deep tank (Steped)

A400M TankCon f igu ra t i on : 2725m x 1 .3m deep Tank

: 3542m

2

To ta l : 8239m3

A400M MRO HangerRAF Br ize Nor ton

3

3

ASP Tank

Spec ia l i s t Cons ide ra t ions : Load ing Comp l iance

Due to VersaVo id , P luv ia Cube and Aquadra in

be ing independen t l y tes ted accord ing to C IR IA

gu ide l i nes (and by two separa te ins t i t u t i ons ) , ESS

were ab le to p rov ide a l l o f t he spec if i ed tes t da ta .

The in fo rmat ion p rov ided comp l ied to a l l t he

necessary documen ta t ion suc has C IR IA C680 ,

609 and 697 . A l l t es ts ( i nc lud ing compress ive

s t reng th , l a te ra l s t reng th and long te rm c reep

tes ts ) comp l ied to C IR IA gu ide l i nes as ou t l i ned

in C IR IA C697 and fo l l ow ing de f ined methodo logy

ou t l i ned in C680 . On top o f th i s , ESS supp l ied i t sown in -house tes t da ta .

Preformed Tuf lex c loaks are heat we lded to inspect ion chamber openings .

A400M MRO HangerRAF Br ize Nor ton

A400M Tank

Summary :

VersaVo id and P luv ia l Cube p rov ided a des ign

tha t me t a l l o f t he s t r i ngen t requ i remen ts se t by

the loca l au tho r i t y and the H ighways Agency

inc lud ing C IR IA requ i remen ts fo r bo th load ing and access .

Modu la r con f igu ra t ion a l l owed fo r a f l ex ib le ,

i dea l s i t e so lu t i on tha t worked w i th o the r

ex i s t i ng i n f ras t ruc tu re bo th above and be low

g round leve l . The modu la r assemb ly fu r the r

reduced ins ta l l a t i on t imes a l l ow ing a much more

economica l so lu t i on to be found .

Load bear ing capab i l i t i es and h igh vo id ra t i os

p rov ided the mos t e f f i c i en t so lu t i on fo r a

res t r i c ted s i te w i th l oad ing i ssues .

A400M MRO HangerRAF Br ize Nor ton

The c l i en t had spec i f i ed fo r access as a ma in

p r io r i t y o f t he ins ta l l a t i on . VersaVo id ’s & Pluvial cube’s

un ique , open and access ib le s t ruc tu re was

immed ia te l y ab le to p rov ide to ta l access w i th the

add i t i on o f an ex te rna l access po in ts . Fo r

ve r t i ca l and ho r i zon ta l access ESS sugges ted inspec t ion un i t s

to be ins ta l l ed above the tank and on the s ides ,

a l l ow ing sa fe access tha t d id no t i n te r fe re w i th

the heavy t ra f f i c f l ows .

For ho r i zon ta l access p ipes were ins ta l l ed on a l l

t h e s i d e s o f t he tanks and 600 d ia access chambers

were ins ta l l ed above each in le t /ou t le t p ipes .

Th is p rov ided comp le te access th roughou t the tank fo r

any fu tu re ma in tenance / inspec t ion to be ca r r ied ou t .

Spec ia l i s t Cons ide ra t ions : Access