UTILITIES NOTE: BEFORE THE START OF CONSTRUCTION, THE OWNER OF ANY UTILITIES INVOLVED MUST BE NOTIFIED. THE EXCAVATOR/CONTRACTOR IS RESPONSIBLE FOR GIVING THIS NOTICE BY CALLING "DIGGER'S HOTLINE" AT 1-800-331-5666 AT LEAST 48 HOURS PRIOR TO ANY EXCAVATION.
AutoCAD SHX Text
ALL WRITTEN SCALES ARE ACCURATE ON 24x36 INCH SHEETS
AutoCAD SHX Text
LOCATED IN SECTION 5 TOWNSHIP 3N, RANGE 15W, 6TH P.M. FRANKLIN COUNTY, NEBRASKA
DU REGIONAL ENGINEER: BEN CHAVEZ 2121 N. WEBB ROAD, SUITE 309 GRAND ISLAND, NE 68803 (308) 379-4974
AutoCAD SHX Text
MMM
AutoCAD SHX Text
BC
AutoCAD SHX Text
BC
AutoCAD SHX Text
BC
AutoCAD SHX Text
MMM
AutoCAD SHX Text
N
AutoCAD SHX Text
SPECIFICATIONS SPECIFICATIONS 101 GENERAL CONDITIONS GENERAL CONDITIONS 102 SUPPLEMENTAL CONDITIONS SUPPLEMENTAL CONDITIONS 201 MOBILIZATION MOBILIZATION 202 SITE PREPARATION SITE PREPARATION 313 PUMP INSTALLATION PUMP INSTALLATION 314 WATER WELL DRILLING WATER WELL DRILLING 315 SUPPLY OF ELECTRICAL POWER SUPPLY OF ELECTRICAL POWER 320 WATER PIPELINE INSTALLATION WATER PIPELINE INSTALLATION
AutoCAD SHX Text
PLAN INDEX PLAN INDEX 1 LOCATION & VICINITY MAPS LOCATION & VICINITY MAPS 2 WELL & LIVESTOCK TANK PLAN WELL & LIVESTOCK TANK PLAN 3 TANK DETAILSTANK DETAILS
AutoCAD SHX Text
ESTIMATED QUANTITIES MOBILIZATION 1 L.S. 1 L.S. L.S. SITE PREPARATION 1 L.S. 1 L.S. L.S. WATER WELL DRILLING 290 L.F.-A* 290 L.F.-A* L.F.-A* SUPPLY OF ELECTRICAL POWER 1 L.S. 1 L.S. L.S. PUMP INSTALLATION 1 L.S. 1 L.S. L.S. LIVESTOCK TANKS 4 EA. 4 EA. EA. TANK GUARD RAIL 1 L.S. 1 L.S. L.S. WELL GUARD RAIL 1 L.S. 1 L.S. L.S. 4' WALK THROUGH GATE 1 EA. 1 EA. EA. STOCK TANK RAMPS 4 E.A. 4 E.A. E.A. ROCK BASE AND APRON 12 C.Y.-P.** 12 C.Y.-P.** C.Y.-P.** * PAYMENT WILL BE BASED ON THE ACTUAL DEPTH OF THE WELL ** PAYMENT WILL BE BASED ON THE PLAN QUANTITY
S RD
27
R
D.
AutoCAD SHX Text
CONSTRUCT LIVESTOCK WELL & INSTALL STOCK TANKS. WELL CENTER COORDINATES: N=14,621,053.94 E=1,628,145.91
AutoCAD SHX Text
EXISTING 24' GATE
AutoCAD SHX Text
EXISTING 16' GATE
AutoCAD SHX Text
EXISTING BARBED WIRE FENCE
AutoCAD SHX Text
SEE LIVESTOCK TANK PLAN VIEW. SEE DETAILS ON SHEET 3.
AutoCAD SHX Text
CONSTRUCT LIVESTOCK WELL WITH SOLAR POWERED PUMP (APPROX. DEPTH 290')
AutoCAD SHX Text
INSTALL SOLAR PANEL ARRAY SIZED FOR PUMPING DEMAND.
AutoCAD SHX Text
INSTALL PVC PIPE FROM WELL TO YARD HYDRANT (APPROX. 10')
AutoCAD SHX Text
INC.
AutoCAD SHX Text
UNLIMITED
AutoCAD SHX Text
DUCKS
AutoCAD SHX Text
GREAT PLAINS REGIONAL OFFICE
AutoCAD SHX Text
PROJECT NO.
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
SHEET NO.
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
APPROVED BY:
AutoCAD SHX Text
CHECKED BY:
AutoCAD SHX Text
SURVEYED BY:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
3/28/2018
AutoCAD SHX Text
NE-269-1
AutoCAD SHX Text
RITTERBUSH WPA LIVESTOCK WELL
AutoCAD SHX Text
THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF.
UTILITIES NOTE BEFORE THE START OF CONSTRUCTION, THE OWNER OF ANY UTILITIES INVOLVED MUST BE NOTIFIED. THE CONTRACTOR IS RESPONSIBLE FOR GIVING THIS NOTICE BY CALLING "DIGGER'S HOTLINE" AT (800) 331-5666 AT LEAST 48 HOURS PRIOR TO ANY WORK.
AutoCAD SHX Text
MMM
AutoCAD SHX Text
BC
AutoCAD SHX Text
BC
AutoCAD SHX Text
BC
AutoCAD SHX Text
MMM
AutoCAD SHX Text
GENERAL NOTES 1. ONE HALF FOOT CONTOUR INTERVAL SHOWN IS BASED ON SURVEY DATA. 2. 2012 1 METER RESOLUTION AERIAL IMAGERY IS SHOWN. 3. ITALICIZED TEXT DENOTES EXISTING FEATURE OR EXISTING ELEVATION.
AutoCAD SHX Text
CONTRACTOR SHALL PROVIDE EQUIPMENT, LABOR, AND MATERIALS NECESSARY FOR A COMPLETE FUNCTIONING LIVESTOCK WATER WELL, PUMPING SYSTEM, AND FOUR LIVESTOCK TANKS AS DESCRIBED BELOW: 1. THIS PROJECT IS FOR THE DRILLING, CASING, DEVELOPING, DISINFECTION, AND PERMITTING OF A LIVESTOCK WATER WELL TO AN APPROXIMATE DEPTH OF 290' AND CAPABLE OF PRODUCING 2000 GALLONS PER DAY. THESE ITEMS WILL BE PAID UNDER THE "WATER WELL DRILLING" BID ITEM. 2. CASING DIAMETER SHALL BE 4" MINIMUM INSIDE DIAMETER AND BE OF A MATERIAL SUITABLE FOR THE GEOLOGIC FORMATION AND APPLICATION OF THE WELL. 3. WELL SCREEN SHALL BE 4" MINIMUM INSIDE DIAMETER AND BE OF A MATERIAL SUITABLE FOR THE GEOLOGIC FORMATION AND APPLICATION OF THE WELL. 4. THE CONTRACTOR SHALL INSTALL A PITLESS ADAPTER BELOW THE FROST LINE AND SHALL BE OF A MATERIAL SUITABLE FOR THE GEOLOGIC FORMATION AND APPLICATION OF THE WELL. THIS WILL BE PAID UNDER THE "PUMP INSTALLATION" BID ITEM . 5. WELL MATERIAL AND CONSTRUCTION SHALL COMPLY WITH THE CURRENT NEBRASKA HEALTH AND HUMAN SERVICES WATER WELL STANDARDS AT A MINIMUM. 6. CONTRACTOR SHALL INSTALL A SOLAR POWERED SUBMERSIBLE PUMPING SYSTEM CAPABLE OF PRODUCING 2000 GALLONS PER DAY. THIS SHALL INCLUDE THE PUMP, DISCHARGE PIPE, AND YARD HYDRANT WITH FLOAT CONTROL. THIS WILL BE PAID UNDER BID ITEM "PUMP INSTALLATION". 7. SUPPLY AND INSTALLATION OF ELECTRICAL CONDUIT FROM SOLAR PANELS TO WELL CONTROL BOX, THE PUMP CONTROL BOX, AND ASSOCIATED WIRING, WILL BE PAID UNDER THE "SUPPLY OF ELECTRICAL POWER" BID ITEM. 8. CONTRACTOR SHALL ENSURE ADEQUATE SIZING OF SOLAR ARRAY TO MEET PUMP DEMAND. SOLAR ARRAY SHALL BE FIRMLY ATTACHED TO STEEL POSTS DRIVEN INTO THE GROUND AND SHALL INCLUDE APPROPRIATE ANCHORAGES TO PREVENT EXCESSIVE MOVEMENT. 9. CONTRACTOR SHALL SUPPLY AND INSTALL FOUR 2'x10' DIAMETER GALVANIZED STEEL LIVESTOCK TANKS. TANKS SHALL BE CONNECTED WITH 1" DIAMETER PVC PIPE PLACED 3" BELOW THE RIMS OF THE TANKS. ALL CONNECTIONS SHALL BE WATERTIGHT USING SILICONE CAULK. THIS WILL BE PAID UNDER THE "LIVESTOCK TANK" BID ITEM. 10. CONTRACTOR SHALL SUPPLY AND INSTALL TANK GUARD RAILS WITH FASTENERS AS SHOWN ON SHEET 3 DETAILS, THIS WILL BE PAID UNDER THE "TANK GUARD RAILS" BID ITEM. 11. CONTRACTOR SHALL SUPPLY AND INSTALL WELL GUARD RAILS WITH FASTENERS AS SHOWN ON SHEET 3 DETAILS, THIS WILL BE PAID UNDER THE "WELL GUARD RAILS" BID ITEM. 12. CONTRACTOR SHALL SUPPLY AND INSTALL, COATED STOCK TANK RAMPS AS SHOWN ON SHEET 3 DETAILS, THIS WILL BE PAID UNDER THE "STOCK TANK RAMPS" BID ITEM. 13. CONTRACTOR SHALL SUPPLY AND PLACE 3/4" GRAVEL STOCK TANK BASE AND APRON AS SHOWN ON SHEET 3 DETAILS, THIS WILL BE PAID UNDER THE "ROCK BASE AND APRON" BID ITEM. 14. CONTRACTOR SHALL SUPPLY AND INSTALL, COATED 48"x50" TALL WALK THROUGH GATE MADE WITH 1 5/8" COATED TUBING, INCLUDING HINGES AND CHAIN LATCH AS SHOWN ON SHEET 3 DETAILS, THIS WILL BE PAID UNDER THE "4' WALK THROUGH GATE" BID ITEM.
INSTALL 2"x12"x7'-9" TREATED LUMBER (3 REQUIRED) ON NORTH SIDE & 2"x12"x3'-1" TREATED LUMBER (3 REQUIRED) ON SOUTH SIDE.
AutoCAD SHX Text
TANK SIDE WALL
AutoCAD SHX Text
ATTACH RAMP TO TANK WITH TWO BOLTS.
AutoCAD SHX Text
FOLD LINES
AutoCAD SHX Text
NOTES: 1. RAMPS SHALL BE MADE OF 14 GAUGE EXPANDED METAL RAMPS SHALL BE MADE OF 14 GAUGE EXPANDED METAL WITH 3/4" MAXIMUM OPENING SIZE. 2. RAMP SHALL BE ATTACHED TO THE RIM OF THE TANK USING RAMP SHALL BE ATTACHED TO THE RIM OF THE TANK USING TWO 3/8" BOLTS AND WASHERS. 3. RAMP SHALL BE GALVANIZED OR PAINTED WITH 2 COATS RAMP SHALL BE GALVANIZED OR PAINTED WITH 2 COATS TARGARD COATING BY SHERWIN WILLIAMS.
AutoCAD SHX Text
CONSTRUCT LIVESTOCK WELL WITH SOLAR POWERED PUMP (APPROX. DEPTH 290')
THIS MATERIAL, DATA AND INFORMATION IS THE PROPERTY OF DUCKS UNLIMITED, INC. IT MAY NOT BE USED OR REPRODUCED FOR ANY PURPOSE WITHOUT THE PRIOR WRITTEN CONSENT OF AN AUTHORIZED AGENT OF DUCKS UNLIMITED, INC. DUCKS UNLIMITED, INC. MAKES NO REPRESENTATION OR WARRANTY OF ANY KIND REGARDING THIS MATERIAL, DATA AND INFORMATION, INCLUDING, BUT NOT LIMITED TO, THE ACCURACY OF THE MATERIAL, DATA AND INFORMATION OR ITS SUITABILITY FOR ANY PURPOSE. ALL USE OF THE MATERIAL, DATA AND INFORMATION IS AT THE USERS SOLE RISK. BY USING ANY OF THIS MATERIAL, DATA AND INFORMATION, USER AGREES THAT DUCKS UNLIMITED, INC. IS NOT RESPONSIBLE FOR THEIR USE OF THE MATERIAL, DATA AND INFORMATION OR THE RESULTS THEREOF.