Upload
others
View
4
Download
0
Embed Size (px)
Citation preview
VIEW AA
1.
265
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
1B1
1B1
NOTES:
265
SWITCHDETAIL DM
PLATE-WALL149557-03-CHTSCREWG39-08-12U (2)
PORT-SOLAR, SINGLE000163158 / 328863-01-000SCREWG39-10-12U (4)
PANEL-SERVICE000017108 / 313328-01-CHTSCREWG39-08-12U (4)
WIRE ASM-TANK,MAIN HOLDING151317-03-000
WIRE ASM-HEATER,TANKS191919-01-000
WIRE ASM-TANK,AUX HOLDING151316-04-000
AA
DRAINAGE SYSTEM/HEAT-PREWIRE23R
DRAINAGE SYSTEM-HEATED23T
SPLICE YELLOW TO RED AND WHITE TO BLACK.2
23T
2
23R
GROMMET023942-01-000
3 WIRE PASSES THROUGH FLOOR IN THIS AREA.
3
3
UNSPECIFIED TOLERANCES: MATERIAL:
C
D
1
TWO-PLACE (X.XX)
DSNR:
DESCRIPTION:
8
2
B
ALL DIMENSIONS ARE IN MILLIMETERSDFTR:
6
A
6
FIRST USED:
A
REV
WHOLE DIM (X)
D
REF:
8
ITEM/PART NO:
4
WEIGHT: (LBS)
SHEET:
7
B
2
4
REFER TO ES0018 FOR FASTENERTIGHTENING GUIDELINES
ANGLE
5
5
13
COPYRIGHT 2016 WINNEBAGO INDUSTRIES, INC.
ONE-PLACE (X.X)
C
7
WIRING INSTL-BODY,12V
1 OF 6 000118447 / 32242501000
3
1.5
0.50
1
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
18 423T
INPUT CONNECTIONS
CABLEPORTABLE
SATELLITEDISH
WATERPUMP
07-May-2018
SPEAKER171547-01-CHTSPACER178966-01-CHTSCREWG11-08-16U (4)
LIGHT-TAPE,LED187693-35-CHT
TO WIRE ASM-ROOF
ADAPTER-COAX082134-01-000 (2)
SWITCHDETAIL DC
SWITCHDETAIL DA
SWITCHDETAIL DD
SWITCHDETAIL DB
PLATE-WALL,KEYSTONE175530-04-CHT (2)
WIRE ASM-HEATER,RELAY153891-01-000
RELAY063912-02-000
CONTROL-WATER PUMP176001-01-000DETAIL BA
WIRE ASM-TANK,WATER151317-02-000
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
1.
2 CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
12,9,2-PIN HSGS TOWIRE ASM-CHASSIS
GROMMET114208-06-000
TV - BEDROOM WITHOUT68T
68TWALLPLATE-TV149557-13-CHTSCREWG12-06-08U (2)
68T
TO FURNACE
XXZ
JY
YYF
JA
Sw
itch
Ba
ttery
Gro
und
Lo
ad
WATER PUMP CONTROL
DETAIL BA
WIRE ASM-LEFT000122961 / 323516-01-000
2
23T23R
23T23R23R DRAINAGE SYSTEM/HEAT-PREWIRE
23T DRAINAGE SYSTEM-HEATED
PSSLED-22
WIRE PASSES THROUGH FLOOR IN THIS AREA.
FROM WIRE ASM-ROOF
3
3
DROP TOSERVICE PANEL
RCA-3 WAY CABLE, HDMI CABLE, COAX (BRN)JC, NC AND 2-PIN HSG FROM WIRE ASM-ROOF AREROUTED OUT END OF ROOF, IN BACKWALL CAP THENTHROUGH BACKWALL TO WALL PLATES.
PRLED-2
JP TOSTOVE GROUND
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000118447 / 32242501000 2 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
SWITCH ON LAMP TO BE ORIENTATEDTO THE REAR OF THE CABINET.
4
4
07-May-2018
NOTES:
AT MINIMUM ALL WIRES TO BE SUPPORTED AND SECURED PER CODEREQUIREMENTS. USE CLAMP 10495 OR 10497 OR WIRE TIE 8343 OR108046 AND SCREW G67-XX-XXX OR G56-XX-XXX AS APPROPRIATEFOR INSTALLATION.
CABLE TO BE MARKED WITH YELLOW TAPE AT EACH END.
1.
2 CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265CABLE TO BE MARKED WITH BROWN TAPE AT EACH END.3
PLATE-WALL(REF)
ADAPTER-COAX082134-01-000
GROMMET114208-06-000
USB-CHARGER188312-01-000
COVER-FORMED,CONTROLLER000026016 / 315473-01-CHTSCREWG11-08-12U (4)LABEL098379-09-000
PLATE-WALL,COAX EXTERIOR183638-01-CHT
RELAY063912-02-000
LOAD CENTERDETAIL EA
LIGHT-TAPE, LED187693-23-CHT
SPEAKER171547-01-CHT (2)SCREWG39-10-12U (8)
CLAMP-CLOSED10497-02-000 (2)SCREWG11-08-16U (2)
LIGHT-TAPE, LED187693-30-CHT
USB-CHARGER188312-01-000
PSSLED-2
SPEAKER171547-01-CHT (3)SPACER-SPEAKER178966-01-CHT (3)SCREWG11-08-12U (12)
USB-CHARGER188312-01-000
SWITCH(REF)
6
WIRE ASM-SOLAR PANEL191761-01-000
MOUNT SWITCH AND SPACER TO BLOCK ON JAMB.ADJUST HEIGHT TO MATCH MAGNET.
SWITCHESDETAIL DG
5
LIGHT-TAPE, LED187693-10-CHT (2)
MOUNT MAGNET USING PILOT HOLES IN SCREEN DOOR FRAME.MOUNT WITH MAGNET TOWARD SWITCH.
HARNESS-SLIDEOUT MOTOR191661-02-000(BRN)
DETAIL CB
CLAMP-CABLE010495-02-000 (8)
GROMMET8386-01-000
CA
DH
HARNESS-SLIDEOUT MOTOR191661-01-000(YEL)
SWITCHESDETAIL DF
SWITCHDETAIL DE
TO WATER HEATER
LPGD
5
JAMB-DOOR
SWITCH/MAGNET-STEP,ELECTRIC116995-03-000SCREWG11-06-06U (2)
ROUTE WIRESTHRU HOLE
6
3
2
VIEW CA
4 SEE WIRING INSTL-TV/DVD FOR ADDITIONAL INFORMATION.
4
4WIRE ASM-OVHD,RIGHT191706-01-000
WIRE ASM-RIGHT000119290 / 322532-01-000
WIRE ASM-SLIDEOUT000119292 / 322535-01-000
PSSLED-22
PSSLED-2
DOOR SWITCHDETAIL CB
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000118447 / 32242501000 3 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
REMOVE SCREWS FROM MAGNET SWITCH TO INSTALLLOCK WASHER AND RING TERMINALS.
7
WASHER-LOCK000007554 / 310611-01-000 (2)
8
7
LIGHT-TAPE, LED187693-10-CHT (2)
SEE DETAIL CC FOR CONNECTION OF LIGHT-TAPESTO WIRE ASM.
8
8
BLKRED
SH-1SH-1
WIRE ASM
DETAIL CC
WIRE ASM
LIGHT-TAPES
LIGHT-TAPES LIGHT-TAPES
LIGHT-TAPES
YELWHT
2-PIN HSG FROMWIRE ASM-RIGHTCIRCUITS: XXW,XXV
6-PIN HSG FROMRIGHT REAR ROOMFRONT MOTOR(LT YEL)
6-PIN HSG FROMRIGHT REAR ROOMREAR MOTOR(BRN)
2-PIN HSG FROM WIRE ASM-RIGHTCIRCUIT: DDJ
4-PIN HSG FROM WIRE ASM-RIGHTCIRCUITS: ACC,ACD,HHG,HHH
CONTROL-SLIDEOUT, IN-WALL189400-01-000
SWITCHESDETAIL DL
RECEPTACLE-12V132958-01-000
64A
RECEPTACLE-12V132958-01-000
RECEPTACLE-12V132958-01-000
CONVERTERDETAIL EB
JACKS-STABILIZING, ELECTRIC64A
SWITCH ON LAMP TO BE ORIENTATEDTO THE REAR OF THE CABINET.
9
9
9
07-May-2018
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL DB
JCPC
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL DC
JDPE
SWITCH-ROCKER135740-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL DE
JDWX
SWITCH-ROCKER135740-01-CHT (2)SWITCH-BASE135741-02-CHTSWITCH-BEZEL135742-02-CHTSCREWG11-08-08U (4)
DETAIL DD
JCPH
JCPG
SWITCH-ROCKER135740-01-CHT (3)SWITCH-BASE135741-03-CHTSWITCH-BEZEL135742-03-CHTSCREWG11-08-08U (4)
DETAIL DG
JCPK
JDA
JCPJ
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
DRAINAGE SYSTEM-HEATED
DRAINAGE SYSTEM/HEAT-PREWIRE
2651B1
1B1
265
23T
23R
DETAIL DA
SWITCH-ROCKER108357-21-000ACTUATOR-SWITCH108356-23-CHTPLATE-SWITCH144363-02-CHTSCREWG11-06-10U (2)
DETAIL DF
VIEW DH
DETAIL DK
SWITCH-ROCKER108357-21-000ACTUATOR-SWITCH108356-23-CHT
VIEW DM
SOLAR PANELCONNECTION
BATTERYCONNECTION
(8 GRN) (GLD)
(8 BLK) (GLD)
WIRE ASM-SOLAR CONTROLLER
WIRE ASM-SOLAR PANEL
(8 BLK) (YEL)
(8 GRN) (YEL)
23R23T
PLATE-SWITCH144363-02-CHTSCREWG11-08-08U (2)
SWITCH-ROCKER108357-18-000ACTUATOR-SWITCH108356-31-CHTCIRCUITSHHH,BW,HHG
LABEL-SWITCH,HTR,HOLDING TK(REF)
LABEL-WARNING,SLIDEOUT116549-02-000
SEE OPERATORS MANUAL
LABEL-SWITCH,HTR,HOLDING TK134563-01-CHT
TURN OFF When Not In Use
SWITCHDETAIL DJ
HOLDING TANK HEATER
CONTROL-CHARGE,SOLAR 30 AMP191278-01-000SCREWG11-08-08U (2)DETAIL DK
PANEL-MONITOR,LCD175724-01-000SCREWG11-08-08U (4)
THERMOSTAT-FURNACE115764-01-CHTSCREWG11-08-08U (2)
SWITCH-ROCKER135740-06-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U (2)
DETAIL DJ
JAHRJP
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000118447 / 32242501000 4 OF 6
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
SWITCH-ROCKER108357-19-000CIRCUITS: ER,ES
40A
SWITCH-ROCKER108357-18-000ACTUATOR-SWITCH108356-19-CHTCIRCUITS: LH,LG,LJ-1,JC,NCWIRE ASM-THERMISTOR186796-01-000
401
SWITCH-ROCKER108357-01-000ACTUATOR-SWITCH108356-22-CHTCIRCUITSFFD,FFT
SWITCH-ROCKER108357-06-000ACTUATOR-SWITCH108356-12-CHTCIRCUITS: FFN,FFP,FFR
SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-28-CHTCIRCUITS:RS,ZZK,NC
40A
SWITCH-ROCKER108357-14-000ACTUATOR-SWITCH108356-03-CHTCIRCUITS:AES,AET,NC
REMOTE PANEL-INVERTER000037772 / 318694-01-CHTSCREWG11-06-08U (2)CABLE-DATA000038250 / 318769-01-000SWITCH-BLANK138253-01-CHTSWITCH-BASE135741-01-CHTSWITCH-BEZEL135742-01-CHTSCREWG11-08-08U
PLATE-SWITCH000022055 / 314395-01-CHTSCREWG11-06-10U (4)
INVERTER-DC/AC WITHOUT
DETAIL DL
SWITCH-ROCKER108357-06-000 (2)ACTUATOR108356-01-000 (2)LABEL000007799 / 310651-01-CHTSWITCH-BLANK096241-03-000 (2)PLATE-SWITCH144363-02-CHT (2)SCREWG11-08-08U (4)
64A
64A JACKS-STABILIZING, ELECTRIC
401 INVERTER-DC/AC, 1000 WATT
60T
60T JACKS-STABILIZING,ELECT W/O
64A
WATERPUMP
Stop
Battery
Start
Water
GenSetONE PLACE
Pump
Meter
Levels
HeaterL.P. Tank
HeaterElectric
116549-02G
CRUSH HAZARD. Keep people and objectsclear of the inside and outside of the slideoutroom when operating. Failure to comply couldresult in death or serious injury.
WARNING
SEE OPERATORS MANUAL
HOLDING TANK HEATERTURN OFF When Not In Use
ON
AWNING
OFF IN
OUT
AWNING
WATERPUMP
310651-01A
--- RETRACT ---
--- EXTEND ---
STABILIZERS
07-May-2018
NOTES:
SEE WIRING INSTL-CHASSIS FOR ADDITIONAL INFORMATION.1
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
DETAIL EBVIEW EA
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000118447 / 32242501000 5 OF 6
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
ET10 YEL(REFRIGERATOR)
WB16 YEL(LP/CO DETECTOR)
JC14 YEL(LAMPS)
JG14 YEL(12V OUTLETS)
NM12 YEL(TANK HEATERS)
JD14 YEL(LAMPS)(SATELLITE PREP)
JE14 YEL(AUDIO/VISUAL)
FFD12 YEL(AWNING)
JB14 YEL(FURNACE)(VENTS)
JA12 YEL(WATER PUMP)(MONITOR PANEL)(ISOLATED CIRCUIT)
XXV10 YEL(SLIDEOUT)
23T 23R
23T
FUSE62901-08-000(30 AMP)
FUSE62901-05-000 (8)(15 AMP)
FUSE62901-05-000(15 AMP)
FUSE62901-02-000(5 AMP)
1
TO CHASSIS GND
"T"PART OF
WIRE ASM-CHASSIS
"L"PART OF WIRE ASM-RIGHT
EXTERNALGROUND BAR
"J" FROMWIRE ASM-CHASSIS
"M"PART OF WIRE ASM-RIGHT
CONVERTER-45 AMP184353-01-000SCREWG67-10-12U (3)
PART OFWIRE ASM-GROUNDS LOAD CENTER
(REF)
23R
23R
DRAINAGE SYSTEM-HEATED23T
DRAINAGE SYSTEM/HEAT-PREWIRE
30
5
15
15
15
15
15
15
15
15
15
5
AMPS
11
AC BRANCH CIRCUIT
7
MAIN 1
AMPS
2
AMPS
3
AMPS
AMPS
30 AMP MAX
AMPS
9
12
DC BRANCH CIRCUIT
10
AMPS30 AMP MAX
AMPS
AMPS
4
30 AMP MAX
AMPS
8
AMPS
30 AMP MAX
6
AMPS
07-May-2018
NOTES:
SEE ANTENNA INSTALLATION MANUAL FORCORRECT INSTALLATION PROCEDURE.
WRAP BRACKET LEGS AROUND ANTENNA BASE.2
1
CODES/STANDARDS USA
CODES/STANDARDS-CSA/CMVSS
2651B1
1B1
265
1
PORT-SOLAR,3 POSITION191277-01-CHTDETAIL FC
DETAIL FB DETAIL FB
PANEL-SOLAR(REF) PORT-SOLAR
(REF)
A/C CUTOUT(REF)
DETAIL FC
WIRE ASM-SOLAR PANEL
8 BLK TO EMPTYPOST ON30A BREAKER
8 GRN TO GROUND STUD(STACK GROUND WIRES)
PORT-SOLAR(REF)
PRLED-48
BRACKET ANTENNAGROUND
NDFROM WIRE ASM-ROOF
VIEW FA
2
158
4
7
SHEET:
2
4
C
A
DESCRIPTION:
B
3 2
REV
A
ITEM/PART NO:
3
D
6
78
D
5
B
C
16
WIRING INSTL-BODY,12V
000118447 / 32242501000 6 OF 6
FOR ELECTRICALTORQUE
SPECIFICATIONSSEE DWG NO.
128783-01-000
X-X
FORELECTRICAL
CALLOUTSSEE DWG NO.
121339-01-000
ANTENNA-TV ROOF000039180 / 318992-01-CHTSCREWG67-10-12U (6)
466
ANTENNA-RADIO,16 RUBBER090944-01-000BRACKET-ANTENNA GROUND147741-01-CHTVIEW FA
PANEL-SOLAR 100 WATT, FLEXIBLE000131101 / 325665-01-000 (2)WASHER077071-01-000 (12)SCREW000G39-10-16U (12)
308
357
47
07-May-2018