998-5104E 1
Abaxis Data Manager Installation Instructions
The Abaxis Data Manager (ADM) is a 32 bit Windows® application that saves Blood
Chemistry Analyzer and VetScan HM5 Analyzer results as files on a 32 bit or 64 bit
Windows® PC.
Using the Abaxis Data Manager you will:
Save Abaxis Blood Chemistry Analyzer results as files on a Windows® PC.
Save VetScan HM5 Analyzer results as files on a Windows® PC.Save Piccolo
Classic, Piccolo xpress, VetScan and VetScan VS2 results in PDF format.
Save VetScan HM5 / HM5c results in PDF format.
Save Blood Chemistry Analyzer and VetScan HM5 Analyzer results as a
Combined Report in PDF format.
Automatically print PDF reports and text files.
Send results from the Blood Chemistry Analyzer and / or VetScan HM5 Analyzer
directly to Abaxis Data Manager and PMS applications at the same time.
Upload results from Blood Chemistry Analyzer and VetScan HM5 Analyzer for
remote diagnostics.
Automatically establish a connection with up to eight (8) Abaxis Analyzers
simultaneously.
This installation guide describes the essential tasks needed to install and configure the
Abaxis Data Manager. You will have successfully completed the Abaxis Data Manager
installation when you can transmit data from the Abaxis Analyzer and VetScan
HM5Analyzer and view analyzer result files stored on the local PC.
Required Materials
Abaxis Blood Chemistry Analyzer.
Abaxis VetScan HM5 or HM5c.
998-5104E 2
Piccolo xpress and VetScan VS2 require software version 2.1.33 or greater.
VetScan HM5 require software version 1.40 or greater. VetScan HM5c require
software version 2.0 or greater.
Windows 7 SP1 (x86 or x64) or 8.1 (x86 or x64) or 10 (x86 or x64) PC, Professional
or higher with 2GB or more of RAM, high speed Internet connection and
administrator privileges.
USB Type A Male / Type B Male Cable for Piccolo xpress and VetScan VS2
Analyzers.
USB Type A Male / Type B Male Cable for VetScan HM5 Analyzers.
Serial Cable - Male / Female for Piccolo Classic and VetScan Classic Analyzers.
USB and serial cables are available from Abaxis Technical Support 1-800-822-2947.
The screen shots in these instructions are from a typical Windows 7 SP1, 8.1 and 10
installations. Dialog boxes shown may vary slightly in Windows servers with different
level of security settings.
998-5104E 3
Abaxis Data Manager Installation
Windows 7 OS:
Install Abaxis Data Manager
Open Internet Explorer.
Navigate to:
https://supportsoftware.abaxis.com/ad
m2
Select the link Abaxis Data Manager
Download to download the software
File Download – Security Warning
Not all users will be prompted with this
dialog box.
Save AbaxisDataManager_v2.X.X.exe
Run As Administrator by right click
on the AbaxisDataManager_v2.X.X.exe
from the saved location
The installation files start extracting to
the same folder
998-5104E 4
Accept
MicroSoft .NET Framework EULA
998-5104E 5
Accept
SQL Server Express LocalDB EULA
Accept
Abaxis End User License Agreement
998-5104E 6
Install Components
Abaxis Data Manager Database setup
Abaxis Data Manager Database
Installer
Installing Abaxis Data Manager PDF
Printer
Not all users will be prompted with this
dialog box.
Installation is complete when the Abaxis
Data Manager starts.
998-5104E 7
Windows 8.1 OS:
Install Abaxis Data Manager
Open Internet Explorer.
Navigate to:
https://supportsoftware.abaxis.com/adm
2
Select the link Abaxis Data Manager
Download to download the software
File Download
Save AbaxisDataManager_v2.X.X.exe
Run As Administrator by right click on
the AbaxisDataManager_v2.X.X.exe from
the saved location
The installation files start extracting to the
same folder
998-5104E 8
Accept
MicroSoft .NET Framework EULA
998-5104E 9
Accept
SQL Server Express LocalDB EULA
998-5104E 10
Accept
Abaxis End User License Agreement
Install Components
Window might prompt for reboot after
.NET Framework installation
998-5104E 11
Abaxis Data Manager Database Setup
Hit any key to continue
Installing Abaxis Data Manager PDF
Printer
Not all users will be prompted with this
dialog box.
Installation is complete when the Abaxis
Data Manager starts.
998-5104E 12
Windows 10 OS:
Install Abaxis Data Manager
Open Internet Explorer.
Navigate to:
https://supportsoftware.abaxis.com/ad
m2
Select the link Abaxis Data Manager
Download to download the software
File Download
Save AbaxisDataManager_v2.X.X.exe
Run As Administrator by right click on
the AbaxisDataManager_v2.X.X.exe
from the saved location
The installation files start extracting to the
same folder
Accept
SQL Server Express LocalDB EULA
998-5104E 13
Accept
Abaxis End User License Agreement
Install Components
Installing SQL Server Express LocalDB
Not all users will be prompted with this
dialog box.
Abaxis Data Manager Database Setup
Not all users will be prompted with this
dialog box.
Installing Abaxis Data Manager PDF
Printer
Not all users will be prompted with this
dialog box.
998-5104E 14
Installation is complete when the Abaxis
Data Manager starts.
998-5104E 15
Abaxis Data Manager Setup
Configure Abaxis Data Manager Enter your clinic
information and path to
custom icon file to be used
on reports if preferred.
Select output formats.
Specify a Save Folder
Path. The Save Folder Path
is the location where result
files will be stored.
Specify how often the
Abaxis Data Manager
should check for Updates.
Save
Continue to either
Piccolo xpress and
VetScan VS2
Configuration. Or
Piccolo Classic and
VetScan Classic
Configuration.
or
VetScan HM5 and HM5c
Configuration.
998-5104E 16
Piccolo xpress and VetScan VS2 Configuration
Configure Analyzer
Verify the Analyzer is not running
a rotor analysis.
Connect the USB Cable to the
Analyzer.
Connect the USB Cable to the PC.
Turn ON the Analyzer, if it is not
already on.
Home > Hand
More Options
Analyzer
ASCII or XML
or
998-5104E 17
Home
Establish Connection with Analyzer
Abaxis Data Manager > Refresh.
Ensure no analyzers are running an
analysis or transmitting data. >
OK.
Locate your Blood Chemistry
Analyzer in Analyzers list.
Transmit Results
Home > Folder
Last Disc/Rotor
Select Xmit
Results
Locate Save Folder Path in the
Abaxis Data Manager Settings.
Windows Explorer (Windows
Key + E) > Navigate to the Save
Folder Path.
Open a file created by the Abaxis
Data Manager.
Success: If there are Blood Chemistry Analyzer
files created by the Abaxis Data Manager in the
Save Folder Path directory you have successfully
completed the installation.
998-5104E 18
Piccolo Classic and VetScan Classic Configuration
Configure Analyzer
Verify the Analyzer is not running
a rotor analysis.
Connect the Serial Cable to the
Analyzer.
Connect the Serial Cable to the
PC.
Turn ON the Analyzer, if it is not
already on.
Configure Piccolo Classic - VetScan Classic customers skip this section.
Press Menu four (4) times >
Analyzer setup menu is displayed
on the screen. Enter.
Press Menu two (2) times > set
data format is displayed on the
screen. Enter.
Right Arrow until ASCII Text
Dump is displayed on the screen.
998-5104E 19
Enter
Press Exit two (2) times.
Establish Connection with Analyzer
Abaxis Data Manager > Refresh
OK.
Locate your Blood Chemistry
Analyzer in Analyzers list.
Transmit Results
Recall
Press Enter two (2) times.
1 (1 - Single Result Card)
Enter
2 (2 - Transmit Patient)
Press Enter two (2) times.
Press Exit five (5) times.
Open drawer to run a disc is
displayed on the screen.
Locate Save Folder Path in the
Abaxis Data Manager Settings.
Windows Explorer (Windows
Key + E) > Navigate to the Save
Folder Path.
998-5104E 20
Open a file created by the Abaxis
Data Manager.
Success: If there are Blood Chemistry Analyzer
files created by the Abaxis Data Manager in the
Save Folder Path directory you have successfully
completed the installation.
998-5104E 21
VetScan HM5 and HM5c Configuration
Configure Analyzer
Verify the Analyzer is not running
an analysis.
Connect the USB Cable to the
Analyzer.
Connect the USB Cable to the PC.
Turn ON the Analyzer, if it is not
already on.
Configure VetScan HM5 to
transmit results to PC:
Click Utilities key
Select 5. Settings > 2.
Customize > 1. General
Settings Set PCLink to USB /
Enabled
Set Serial Protocol Version
to 3.1
Set VSx Link to Offline
Click on Accept
Click Database key
998-5104E 22
Configure VetScan HM5c to
transmit results to PC:
Touch Settings
Touch Measurement
Touch Settings
Set PC Link to Enabled
Set Auto Send to Enabled
Set VSx Link to Disabled
Set PC Link Baud Rate to
9600
Touch Database
(Refer to your VetScan HM5c
User Manual PDF for any details)
Establish Connection with Analyzer
Abaxis Data Manager > Refresh.
Ensure no analyzers are running an
analysis or transmitting data. >
OK.
Locate your VetScan HM5 in
Analyzers list.
Transmit Results
Transmit Results from VetScan
HM5:
Click on Database key
Select the result to
Transmit by using
arrow keys
Click OK key
Click on Menu->4
Manage selected
records->1 Send
selected records
Transmit Results from VetScan
HM5c:
998-5104E 23
Touch Database key
Touch the result to
Transmit
Touch Manage
Touch Send
Touch PC
(Refer to your VetScan HM5c
User Manual PDF for any details)
Locate Save Folder Path in the
Abaxis Data Manager Settings.
Windows Explorer (Windows
Key + E) > Navigate to the Save
Folder Path.
Open a file created by the Abaxis
Data Manager.
Success: If there are VetScan HM5 files created by
the Abaxis Data Manager in the Save Folder Path
directory you have successfully completed the
installation.