ABB ACS800 Maintenance HealthCheck Schedule to protect your production and investment
Note: Recommended maintenance intervals and component replacements are based on specified operational and environmental conditions. ABB recommends annual drive inspections to ensure the highest reliability and optimum performance.
Performance of on-site work (commissioning, tests, measurements etc.)
Replacement of component (at rated loads and ambient conditions)
Inspection (visual inspection, correction and replacement if needed)
ACS800-01/04Years from start-up
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Start-up P
Cooling, air cooled
Internal/additional cooling fan for ACS800-01, -04, -11, -31, -104 (IP20, IP21 and IP55)
R R R R R R R
Cooling fan for ACS800-01, -02, -04, , ALCL I R I R I R I
Ageing
Electrolytic capacitors (DC circuit) R R
Memory backup battery replacement in APBU-xx unit R R R
ALCL filter capacitor I R I R I R I
Connections and environment
AINT+ flat cables, CINT, NRED, discharging resistors R R
Air filters (IP20 to IP42) I I I I I I I I I I I I I I I I I I I I I
Air filters (IP54 and over) R R R R R R R R R R R R R R R R R R R R R
Cleanliness check (dustiness, corrosion and temperature) and/or heat sink cleaning
I I I I I I I I I I I I I I I I I I I I I
Improvements
Based on product notes I I I I I I I
Typical Service Intervals, just like our cars, based on run hours
Call us to arrange your Drive HealthCheck today
Ask us about Thermal Site Surveys
3 yearsTypical internal fan change and inspection
18,000 hrs Service
36,000 hrs Service
6 years Typical internal and main cooling fan change and inspection
54,000 hrs Service
9 yearsTypical internal, main cooling fan and capacitors change and inspection
© Sentridge Control 2015
Tel: 024 7655 3303Tel: 01782 444 655
www.sentridge.com
ABB ACS550 /ACH550 Maintenance HealthCheck Schedule to protect your production and investment
Note: Recommended maintenance intervals and component replacements are based on specified operational and environmental conditions. ABB recommends annual drive inspections to ensure the highest reliability and optimum performance.
Performance of on-site work (commissioning, tests, measurements etc.)
Replacement of component (at rated loads and ambient conditions)
Inspection (visual inspection, correction and replacement if needed)
ACS550/ACH550Years from start-up
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21
Start-up P
Cooling
Internal/additional cooling fan R R R R R R R
Cooling fan (ACx550-01) I R I R I R I
Cooling fan (ACS550-02) I R I R I R I
Ageing
Electrolytic capacitors (DC circuit) R R
Connections and environment
OITF + flat cables R R
Tightness of terminals I I I I
Dustiness, corrosion and temperature I I I I I I I
Improvements
Based on product notes I I I I I I I
Typical Service Intervals, just like our cars, based on run hours
Call us to arrange your Drive HealthCheck today
Ask us about Thermal Site Surveys
3 yearsTypical internal fan change and inspection
18,000 hrs Service
36,000 hrs Service
6 years Typical internal and main cooling fan change and inspection
54,000 hrs Service
9 yearsTypical internal, main cooling fan and capacitors change and inspection