    Abis data configuration

  • 8/8/2019 Abis Data Configuration

    2/17

    Contents:

    I- BSC side(data configuration)

    I-1 IP address planning

    I-2 steps of data configuration I-3 Commissioning

    II- BTS side (data configuration)

    II-1 Steps of the configuration

    II-2 Commissioning

  • 8/8/2019 Abis Data Configuration

    3/17

    I-BSC side

    In this step according to the RNP planning

    we choose the subrack where is locate the

    BTS. The PEUB and the SPU (XPU)should be locate on this subrack.

  • 8/8/2019 Abis Data Configuration

    4/17

    I-1 IP address planning

    PEUB/ BCIM address:

    For this bords we use 168 networksegment.the second digit calculated by thefollowing formula:subrackNo*20+unit ofslot No. Set the third digit to 0 for thePEUB and to the link group number for the

    BCIM. Set the fourth digit to 1 for thePEUB and 2 for the BCIM.

  • 8/8/2019 Abis Data Configuration

    5/17

    I-1 IP address planning

    MLPPP Local and Peer ADDR :

    Set the ip addresses in the 172 network

    segment. the second digit calculated bythe following formula:subrackNo*20+unit

    of slot No. Set the third digit to the link

    group number. Set the fourth to 1 for the

    BSC and 2 for the BTS

  • 8/8/2019 Abis Data Configuration

    6/17

    I-2 stepsofdata configuration

    Abis interface link mode:ADD MLPPPLNK: FN=2, SN=27, MLPPPGRP=1, LNKLST="1", E1T1LST=0",E1T1MODE=E1,

    E1TSBITMAP=TS_1&TS_2&TS_3&TS_4&TS_5&TS_6&TS_7&TS_8&TS_9&TS_10&TS_11&T

    S_12&TS_13&TS_14&TS_15&TS_16&TS_17&TS_18&TS_19&TS_20&TS_21&TS_22&TS_23&

    TS_24&TS_25&TS_26&TS_27&TS_28&TS_29&TS_30&TS_31,LIPADDR="172.47.0.1",

    PIPADDR="172.47.0.2", LQR=NO, PFC=YES, ACFC=YES, HCMP=YES, HCMPTYP=UDP+IP,

    MCTYPE=LONG, PPPMUXEN=ON, AUTHMODE=NO, BEARTYP=BOTHSIGTRF;

    BTS basic information:ADD BSCBTSINF:BTSTP=IBSC, BTSID=1003, BTSNM="BTS1003", FN=2, SN=4, SSN=1,ABISCAPOPTMSW=OFF, ABISOPTMCRCSW=OFF, ABISREVFRAMEPERIOD=3,

    HIGHPW=NOHIGHPW, ABISREDUNDANCESW=OFF, INTRAFADAPFILTER=OFF;

  • 8/8/2019 Abis Data Configuration

    7/17

    I-2 stepsofdata configuration

    OML link:ADD BTSOMLNK: BTSID=1003, SPUFN=2, IFBSN=27, LM=MLPPP,

    BCIMIP="168.47.0.2", MLPPPGRP=0;

    Signaling link:ADD BTSSIGLNK: BTSID=1003, SPUFN=2, IFBSN=27, LM=MLPPP,

    BCIMIP="168.47.0.2", MLPPPGRP=0;

    Traffic link:ADD BTSTRFLNK: BTSID=1003, SPUFN=2, IFBSN=27, LM=MLPPP,

    BCIMIP="168.47.0.2", TRFLNKFLG=0, MLPPPGRP=0;

  • 8/8/2019 Abis Data Configuration

    8/17

    I-2 stepsofdata configuration

    Cell and Sector:ADDCELL: BTSID=1003, FN=2, CN=1003, SCTIDLST="0", PNLST="88", SID=8704, NID=1,

    PZID=1, LAC="0x102", LCN=1003, LSCTID="0", ASSALW1X=NO, ASSALWDO=NO,

    IFBORDCELL=NO, REVRSSICARRASSNSW=OFF, DOAREVRSSICARRASSNSW=OFF,

    DOAPRVPRIASSSW=OFF, DOMULTIBANDASSIGNSW=OFF,

    AUTODWNFWDEQLCHANTHD=20, AUTODWNCOUNTTHD=600,UNBLKFWDEQLCHANTHD=40, DOUSERCOUNTTHD=20, DOAUTODWNCOUNTTHD=600,

    DOUNBLKUSERCOUNTTHD=40, CTLAC="0xFFF";

    NB:Weshould add cell for 1x and EVDO services. TheCell No

    forthe EVDO start by 15xx.You mustseparatethe Sector ID Lists and Pseudo NoiseCode Lists

    entered by commas.

  • 8/8/2019 Abis Data Configuration

    9/17

    I-2 stepsofdata configuration

    carrierof local BSC:ADDCDMACH: CN=1003, SCTID=0, CRRIDLST="11", BNDCLS=BC800,

    ARFCNLST="185", TYP=CDMA2000, IFBCDMACH=NO, CCLMFLG=NO,

    ECCLMFLG=NO, IFTCDMACH=NO, AUTODWNCDMACH=NO;

    ADDCDMACH: CN=1503, SCTID=0, CRRIDLST="18", BNDCLS=BC800,

    ARFCNLST="308", TYP=EVDO, COLORCODE=1, SECTORID24="0x001007",

    EVDOPROVER=RELEASEA, AUTODWNCDMACH=NO;

    Add BTS:ADD BTS: BTSID=1003, OMCIP=129.11.99.235, BTSTP=DBS3900_CDMA;

  • 8/8/2019 Abis Data Configuration

    10/17

    I-3 Commissioning

    Check the basic information:

    LST BSCBTSINF

    Check the BTS link:LST BTSLNK

    LST BTS

    Query the Cell and carrierr information:

    LST CELL

    LST CDMACH

  • 8/8/2019 Abis Data Configuration

    11/17

    II- BTS side (data configuration)

    To achieve this step the transmission

    between BSC and BTS must be up and

    the BTS also must be power on. So it very

    import to cooperate with the transmission

    and site engineer.

  • 8/8/2019 Abis Data Configuration

    12/17

    II-1 Stepsofthe configuration

    Basic information cfgCLR CBTSCFG: BTSID=1003;

    SET CBTSINFO: BTSID=1003, BTSTP=CBTS, BTSCLASS=DBS3900_CDMA, CONFIRM=Y;

    NB: BTS ID must be consistent withthe ID whichis already

    configured in BSCside. (ADD BSCBTSINF).

    UseCLR CBTSCFG to clearthe current configuration data of

    the BTS .

  • 8/8/2019 Abis Data Configuration

    13/17

    II-1 Stepsofthe configuration

    Cell cfg:ADDCBTSCELL: BTSID=1003,LOCALCELLID=1003,LOCALSECTORID=0;

    Basebande bord cfg:ADDCBTSCMPT: BTSID=1003,BRDID=0,CONFIRM=Y;

    ADDCBTSUTRP:BTSID=1003,BRDID=4,CONFIRM=Y;

    NB:CMPT correspond to BCKM onthe BTS 3606 and the UTRP to BCIM.

    CE pool CE board cfg:ADDCBTSCPL:BTSID=1003,CPLID=0,CPLMODE=STATIC,CELLMODE=NORMAL;

    ADDCBTSCPL:BTSID=1003,CPLID=1,CPLMODE=STATIC,CELLMODE=NORMAL;ADDCBTSCPL:BTSID=1003,CPLID=2,CPLMODE=STATIC,CELLMODE=NORMAL;ADDCBTSCPM: BTSID=1003,BRDID=2,CPLID=0;

    ADDCBTSCPM: BTSID=1003,BRDID=3,CPLID=1;

    ADDCBTSECM:BTSID=1003,BRDID=0,CPLID=2,WORKINGMODE=CHANNEL3_MODE;

  • 8/8/2019 Abis Data Configuration

    14/17

    II-1 Stepsofthe configuration

    MLPP transnission link cfg:ADDCBTSLNKGRP:BTSID=1003,BRDTP=UTRP,BRDID=4,LNKGRPID=0,LNKGRPTP=MLPPP;

    ADDCBTSLNK:BTSID=1003,BRDTP=UTRP,BRDID=4,LNKID=0,LNKGRPID=0;

  • 8/8/2019 Abis Data Configuration

    15/17

    II-1 Stepsofthe configuration

    Signaling link and traffic link cfg:ADDCBTSTERSIGLNK:BTSID=1003,IPVER=IPV4,BSCIP="80.144.16.131",BTSIP="80.126.4.17

    ",BTSSNM="255.255.0.0",BRDTP=UTRP,BRDID=4,ABISLNKTP=CDMA1XONLY,BEARERTP=IP,P

    ERIP="168.47.0.1",PROTOCOLTP=TCP;

    ADDCBTSTERSIGLNK:BTSID=1003,IPVER=IPV4,BSCIP="80.144.16.131",BTSIP="80.126.4.17",BTSSNM="255.255.0.0",BRDTP=UTRP,BRDID=4,ABISLNKTP=CDMADOONLY,BEARERTP=IP,PE

    ERIP="168.47.0.1",PROTOCOLTP=TCP;

    ADDCBTSIPTERTRFLNK:BTSID=1041,IPLNKID=0,SVCTP=ALL,BRDTP=UTRP,BRDID=4,BUFFM

    NUM=3,LNKLAYERTP=PPP,LNKGRPID=0;

    NB: for each service we should configure a signaling link. One traffic link is used the both service.

    Use LST BTSLNK to query BTSIP address for signaling link and LST SUBSYSTEM to query

    BSCIP address.

  • 8/8/2019 Abis Data Configuration

    16/17

    II-1 Stepsofthe configuration

    RF module cfg:ADDCBTSTRM:BTSID=1003,TRMID=0,RCKTP=RRU,TRMDES="RRU0",MASTERBRD=CPM2,F

    IBPN=0,FIBTS=0;

    ADDCBTSSECTORCARRIER:BTSID=1003, LOCALCELLID=1, LOCALSECTORID=0, CRRID=0,

    TRMID=0,CPLID=0,HPBFLG=NO;

    NB: wehavethree RRUsto configure and eachoneis connecttooneoptical portofthe HCPM.

    Start the BTS:STR CBTS: BTSID=1003;

    Save the current configuration:SAV CBTSCFG: BTSID=1003;

  • 8/8/2019 Abis Data Configuration

    17/17

    II-2 Commissioning

    Check the signaling link status

    DSP SIGLNKSTAT

    Check the resources status:DSP RES

    unblock the resources:

    UBL RES

    Query CE information:

    LST BSCBTSINF