    Baldor Drives

    and Soft Starts

    CA769Effective Date:

    February, 2014

  • 8/9/2019 AC Ddives Baldor CA769

    2/116

  • 8/9/2019 AC Ddives Baldor CA769

    3/116c

    TABLE OF CONTENTS

    Baldor Drives

    AC Drives Selection Chart ................ ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ .......... 1

    VS1 Part Numbers .............. ............... ................ ............... ............... ................ ............... ................ ............... ................ ............... ............... ........ 3

    ACB Part Numbers ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... ................ ............... ..... 3ACS Part Numbers ......... ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ ............... ............. 3

    AC Drives

    VS1ST ..... ............... ............... ................ ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... ..... 9

    VS1MX .............. ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ .......... 14

    VS1MXS ....... ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... 19

    VS1ST / VS1MX Accessories and Options .............. ............... ................ ............... ................ ............... ............... ................ ............... ................ .. 21

    VS1STS / VS1MXS Accessories and Options .............. ............... ................ ............... ................ ............... ................ ............... ............... ............. 25

    ACB330 .............. ................ ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... ............... ........ 26

    ACB330 Option Kits .............. ................ ............... ................ ............... ............... ................ ............... ................ ............... ................ ............... ..... 28

    ACB530 Inverter Drive .... ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ ............... ............. 29

    ACB530 +L502 Vector Drive .............. ................ ............... ............... ................ ............... ................ ............... ................ ............... ............... ........ 36

    ACB530 and ACB530 +L502 Option Kits ............... ............... ................ ............... ................ ............... ............... ................ ............... ................ .. 43

    ACS880 Cooling Tower Drive ................ ............... ................ ............... ............... ................ ............... ................ ............... ................ ............... ..... 44

    ACS880 +N5350 Cooling Tower Drive ............... ............... ................ ............... ............... ................ ............... ................ ............... ............... ........ 47

    Baldor Cooling Tower Control System Overview .............. ............... ............... ................ ............... ................ ............... ............... ................ .......... 48

    Analog AC Drives

    Series 5 Micro Inverters ............... ............... ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... 51

    Common Options

    AC and DC Drives Options and Accessories ................ ............... ................ ............... ................ ............... ............... ................ ............... ............. 56

    Three Phase Line and Load Reactors ................ ............... ................ ............... ............... ................ ............... ................ ............... ............... ........ 60

    DC Drives

    NEMA 1 Enclosed DC Control for PMDC and Shunt Wound Motors ............. ................ ............... ................ ............... ............... ................ .......... 62

    Chassis Mount DC Control ............... ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ .......... 63

    Plug-In Horsepower Resistor and Fuse Kit .............. ............... ................ ............... ................ ............... ............... ................ ............... ................ .. 64

    NEMA 4X DC Control ............... ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... ................ .. 65

    DC SCR NEMA 4X DC Control Accessories .............. ................ ............... ................ ............... ............... ................ ............... ................ ............... 65

    Line Regenerative DC Control and Accessories ................ ................ ............... ............... ................ ............... ................ ............... ............... ........ 66

    NEMA Enclosed DC Control Specifications ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... 67

    Chassis Mount DC Control Specifications ............... ............... ................ ............... ................ ............... ............... ................ ............... ................ .. 68

    DC Control Dimension Diagrams ............. ................ ............... ................ ............... ............... ................ ............... ................ ............... ................ .. 69

    MST Soft Starts

    Soft Starters .............. ............... ............... ................ ............... ................ ............... ................ ............... ............... ................ ............... ................ .. 75

    Application Information ......................................................................................................................................................................................... . 7

    Drives Cross Reference ......................................................................................................................................................................................... . 8

    Glossary of Terms ................................................................................................................................................................................................... . 9

    Index ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ ............... ................ ............... ................ .. 103

    Baldor Drives Service Centers .............. ............... ................ ............... ............... ................ ............... ................ ............... ............... ................ ..... 106

    Baldor Sales Offices.............. ............... ................ ............... ............... ................ ............... ................ ............... ................ ............... ............... ........ 112

  • 8/9/2019 AC Ddives Baldor CA769

    4/116

  • 8/9/2019 AC Ddives Baldor CA769

    5/1161

    AC Drives Selection Chart

    PRICES ARE SUBJECT TO CHANGE WITHOUT NOTICE

    VS1ST VS1STS 600V VS1MX VS1MXS - 600V ACB330

    Main Attributes

    Starter-style Microdrive; V/HzControl, Built-In PI Loop; DIN orPanel Mounting.

    Starter style 600V Microdrive;V/Hz and Sensorless Vector Control;Built-in PID Loop

    Microdrive; NEMA 4X & NEMA 12Enclosures; V/Hz Control; Built-InDisconnect

    NEMA 12 / 600V Microdrive;V/Hz and Sensorless Vector Control;Built-in PID Loop;Built-in Disconnect

    Sensorless vector or V/Hzcontrol, permanent magnet orinduction motor control,PID control, Quick StartAssistant,intuitive LCD keypad

    Hp Range

    230V Hp 0.5 to 5 0.5 to 5Hp 1/2 - 15hp

    460V Hp 1 to 15 1 to 10Hp 1/2-30 Hp

    600V Hp - 1 to 60 (STS) 1-60 Hp 1 to 7.5Hp (MXS) 1-7.5 Hp

    Voltage Range

    115V/230V 1 Phase230V/460V 3 Phase600V 3-Phase 600V 3-Phase

    115V/230V 1-Phase230V/460V 3-Phase600V 3-Phase 600V 3-Phase

    200 - 240V - 1 Phase200 - 240V - 3 Phase380 - 480V - 3 Phase

    Enclosure Selection

    IP20 IP20 NEMA 4X/12 Indoor; NEMA 12;with or w/o Disconnect

    NEMA 12 IP20UL Type 1 Kit Available

    Control Mode

    V/Hz V/Hz and Sensorless V/Hz V/Hz and Sensorless Sensorless Vector or V/Hz

    Communications Options

    Built-In Modbus-RTU (RS-485)DIN RailGateways:

    DeviceNet, Profibus-DP Ethernet/IP

    Modbus/TCP

    Built-in MODBUS-RTUGateways:DeviceNetProfibus-DPEthernet/IPModbus/TCP

    Built-In Modbus-RTU (RS-485)Gateways:DeviceNet, Profibus-DP

    Ethernet/IPModbus/TCP

    Built-in MODBUS-RTUGateways:DeviceNetProfibus-DPEthernet/IPModbus/TCP

    DeviceNet, EtherNet/IP, EtherCAT,Modbus-RTU, Modbus/TCP,PROFIBUS, Profinet-IO

    Operator Interface

    Local or Remote Mounted LEDDisplay and Keypad

    Local or Remote Mounted LEDDisplay and Keypad;Copycat Capability

    Local or Remote Mounted LEDDisplay and Keypad; CopycatCapability; Speed Pot; Fwd/RevSwitch; Input Disconnect

    Local or Remote Mounted LEDDisplay and Keypad; CopycatCapability; Speed Pot; Fwd/RevSwitch;Input Disconnect

    Local or remote mounted LCDdisplay. Parameter upload anddownload capable. Assistantsmode for quick start-up

    See page 9 See page 12 See page 14 See page 19 See page 26

  • 8/9/2019 AC Ddives Baldor CA769

    6/1162

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    AC Drives Selection Chart ContinuedACB530 ACB530 +L502 ACS880 +N5350 Cooling Tower

    Main Attributes

    Sensorless Vector or V/Hz Control,PID Control, Quick Start Assistant,UL Type 1 or UL Type 12 Enclosure,Easy to use keypad

    Closed Loop Vector, Sensorless Vector or V/HzControl, PID Control, Quick Start Assistant, ULType 1 or UL Type 12 Enclosure, Easy to usekeypad

    High-performance drive for control ofCooling Tower PM Motors;NEMA 1 Enclosure; Built-in Braking;Full-Graphic Display

    Hp Range

    3/4 - 100Hp

    1-550 Hp 3/4 - 100Hp

    1-1/2 - 150Hp 1-550 Hp 10-350 Hp

    1-1/2 - 150HpVoltage Range

    230V 1 Phase208-240V 3 Phase380-480V 3 Phase500-600V 3 Phase

    230V 1 Phase208-240V 3 Phase380-480V 3 Phase500-600V 3 Phase

    230V 1 Phase208-240V 3 Phase380-480V 3 Phase500-600V 3 Phase

    Enclosure Selection

    NEMA 1 (UL Type 1) - 3/4-350HpNEMA 12 (UL Type 12) - 3/4-550Hp

    NEMA 1 (UL Type 1) - 3/4-350HPNEMA 12 (UL Type 12) - 3/4-550HP

    NEMA 1

    Control Mode

    Sensor less Vector or V/Hz Closed Loop Vector, Sensor less Vector or V/Hz Open-Loop Perm. Magnet Control

    Communication Options

    Built-in Modbus-RTU,Optional: DeviceNet, PROFIBUS,Modbus/TCP, EtherNet/IP, ControlNet,EtherCAT

    Built-in Modbus-RTU, Optional: DeviceNet,PROFIBUS, Modbus/TCP, EtherNet/IP,ControlNet, EtherCAT

    Built-in power link MODBUS-RTU,DeviceNet, MODBUS-TCP,CANopen, Profibus-DP, ProfiNet-IO,Ethernet/IP, EtherCAT

    Operator Interface

    Advanced Control Panel standard, withtwo soft keys that change state accordingto state of panel, Local / Remote controlmodes, Built-in Help button,Real-time clock,Changed Parameter menu

    Advanced Control Panel standard, with two softkeys that change state according to state ofpanel, Local / Remote control modes, Built-inHelp button, Real-time clock, ChangedParameter menu

    Local or RemoteMounted Graphical LCD Display andKeypad;Copycat Capability;

    See page 29 See page 36 See page 44

    PRICES ARE SUBJECT TO CHANGE WITHOUT NOTICE

  • 8/9/2019 AC Ddives Baldor CA769

    7/1163

    VS1 Part Numbers

    VS1 ST 4 5 - 4 Opts (T, B, D, F, L, P, R)

    Enclosure: Option Codes0 = IP20 T = Transistor (Braking)1 = NEMA 1 B = Braking (Both Trans. & Res.)2 = NEMA 12 D = Disconnect

    4 = NEMA 4X F = Filter (EMC)5 = NEMA 4/12 Dirty Duty9 = Chassis

    Hp:0P5 = 1/2 HP1 = 1 HPetc.

    Voltage:1 = 115V Single-Phase2 = 230V3 = 380 - 400V4 = 460V5 = 600V6 = 115V / 230V Single-Phase

    8 = 230V Single-Phase

    Family (All Series 1):ST = Starter Replacer DriveSTS = 600V - IP20 MicrodriveMX = NEMA 4X MicrodriveMXS = 600V - NEMA 12 Microdrive

    ACB Part Numbers

    ACB 530 - U1 - 07A5 - 2

    Voltage:2 = 230V4 = 460V6 = 600V

    Rating:07A5 = 7.5A

    Type:01U = ACB330 - 1 Phase Input03U = ACB330 - 3 Phase InputU1 = ACB530 - Wall MountPC = ACB530 - Cabinet Drive

    Family:330 = ACB Microdrive530 = ACB General Purpose Drive

    ACS 880 - 01 - 10A6 - 2+N5350

    ACS Part Numbers

    Voltage: 2 = 230V 4 = 460V 6 = 600V

    Rating 10A6 = 10.6A

    Wall Mount

    ACS880 Cooling Tower Drives

  • 8/9/2019 AC Ddives Baldor CA769

    8/1164

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Baldor Drives Center

    Test Capabilities

    Large HP Capability

    Test facilities utilize Baldor regenerative controltechnology on dynamometers for maximum

    performance and energy efficiency. Capabilitiesexist for continuous loading from fractional to800 Hp with the largest dyno being capableof intermittent loading over 1000 Hp. Thedynamometers found throughout the testfacilities are fully instrumented with equipmentto read temperature, speed, torque and power(volts, amps, watts, PF, Hz, VA, VAR, harmonics,etc.) and are fully automated. Hipotronicsvariable AC sources are used in conjunctionwith our largest dynamometers to enabletesting at high, low and nominal line voltages and all points in between.The Hipotronics units are capable of up to 2000 amps, 0-4160 volts and

    are equipped with Yokogawa Power Analyzers for power measurements.Independent control of each phase voltage allows for the introduction of adegree of phase imbalance to test real world conditions. The systems PCmonitors the Hipotronics settings and test conditions and logs test data.

    AST-35 HALT/HASS Chamber

    The AST-35 chamber is designedspecifically for very aggressivetemperature change rates and highlevels of multi-axis repetitive shockvibration. It can be used for a varietyof testing such as HALT, HASS, Step Stress, etc. It is Liquid Nitrogen (LN2) cooled with a temperature range of

    -100C to +200C (-148F to 392F). It can provide up to 50grms of random vibration (2 Hz to 5 kHz). The vibrationtable can support a payload of 200 pounds. It has a 42X42X40 work area and product temperature changerates greater than 70C per minute can be achieved. No matter what method of testing is chosen, the AST systemprovides extreme stresses to help quickly identify potential product weaknesses that in turn help produce a morereliable product.

    Thermal Testing and Analysis

    Several thermal/environmental chambers have testing capabilities from -100 to +200C and humidity capabilities from 10% to 95% RH. The chamberscan be programmed to cycle between multiple set points for varying times.

    A Fluke Infrared Camera is used for thermal imaging. Infrared technology isutilized to analyze components such as IC chips and PCBs, heat sink thermalresistance, fan cooling effects, thermal dissipation characteristics of motors,

    bearing and brush temperatures and many other applications.

  • 8/9/2019 AC Ddives Baldor CA769

    9/1165

    Baldor Drives Center

    Test Capabilities

    Commitment to Safety

    Baldor is committed to accident and injury prevention! All test facility personnel are trained and certified in Basic First Aid and CPR. In addition, the laband production areas have nationally certified First Responders with Pre Hospital Trauma Life Support (PHTLS) training.

    Calibration

    A Fluke 5520A calibrator along with other NIST traceable standards is used to calibrate the majority of the electronic instruments within Baldors test facilities. Inhouse calibration services are also performed on final test panels and electronic instrumentation for other Baldor plants and facilities.

    Surface Mount Technology

    Surface Mount (SMT) soldering and inspection equipment is usedduring prototyping of new designs and upgrades. PCB layout, design,evaluation and testing are also performed.

    Every control is powered up and load tested before it leaves theplant using an automated system. This system first verifies that each

    control is programmed correctly using an interface between the testsystem and BUS. Next, using the VS1 USB interface and standardfirmware, the control is commanded to spin a motor. Output speed isverified using external current transducers and the motor is loadedto 150% of rated current. The control cycles between 150% of rated

    current and 50% rated current for 2 minutes. Reversal tests are then run to testthe braking transistor and resistor functionality. Finally the drive is power cycled,factory defaults are set, and any custom parameters are programmed into thedrive. The results of the test, including the serial numbers of the boards in thecontrol are saved in a database. A shipping label is printed and the control isboxed up ready for shipment. Each control takes about 10 minutes to test and

    up to 5 controls of varying voltages and sizes can be tested at the same time.

    Dyno Technology

    A Labview application developed by Baldor lab technicians control the dynesand monitors all test conditions. Each dyno utilizes Baldor regenerative drivetechnology for optimum performance and efficiency. Each is equipped withvariable voltage sources and 50/60Hz power. Full instrumentation providesmonitoring of temperature, speed, torque, and power (volts, amps, watts, PF, Hz, VA, VAR, harmonics, etc.). The data is transferred directly tocomputers that control and monitor the entire operation. The system completely automates standard test sequences such as brake tests, heat runsand speed versus torque curve tests. It also provides for custom load profiles such as inertia, pump jack and fan and pump load simulations. Eachtest station is networked for direct test data storage to the lab servers as well as allowing tests to be monitored remotely.

    Porto-Sag PS200The Porto-Sag PS200 is used to inject voltage sags of controlled magnitude and duration while monitoring the response of the process.

    Voltage: 100-277VAC Magnitude: 125% to 0% in 5% steps.Current: 200A, 700 A peak for cycle 360 point on wave control in 1 incrementsSag/Swell duration: cycle to 10 seconds

    NSG 2050 Surge Mainframe

    The NSG 2050 is a surge generator with pulse amplitudes up to 6.6kV single or 3-phase coupling network. It covers all the widely used burst testspecs of IEC, EN, ANSI-IEEE as well as extended manufacturers requirements.

  • 8/9/2019 AC Ddives Baldor CA769

    10/1166

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Baldor Drives Center

    Test Capabilities

    UL, CSA, EMI and Immunity Testing

    The test facilities perform required testing for UL approval of Baldor motor and control products and is a participant in the UL Client Test Data Program(CTDP) for UL 508C, UL 2111, UL 1995. Additionally, certifications are held for motor efficiency testing under both CSA and NVLAP. UL short circuit

    testing for drives products is performed in a specifically designed room. This short circuit room is designed to provide a minimum of 50,000 amps ofshort circuit current. Electrostatic Discharge (ESD), Electronic Fast Transient (EFT) andburst equipment is used to test EMI and immunity levels of drive products in accordancewith CE standards.

    Customer Application Testing

    The lab routinely tests Baldor products on customer units in the lab.

    Hardware/Software Test Systems Design

    Lab technicians participate in hardware and software design of lab test equipment,production test equipment and trade show demo units.

    Labview applications developed by lab technicians are used throughout the lab and inmany locations throughout Baldor. One example is the automation of our dynamometersas described above. Another example is the system used to automate the verificationprocess of new software releases for Baldor drive products. The Labview applicationinterfaces with the control just as a customer would and exercises and monitors all inputand output signals of the drive for proper operation and compliance to specified limits. In addition, the system simulates operator keystrokes to thecontrol and monitors motor performance to verify proper operation of the drive under test. Test conditions and results are collected by a PC and storeddirectly to the labs network server. This testing runs 24 hours a day, seven days a week for several weeks at a time in order to verify new softwareversions prior to release. Other applications developed within the lab simulate inertia, fan and pump and pump jack loads, monitor and control longterm life testing, speed versus torque curve collection and tensile testing.

    Every control is powered up and load tested before it leaves the plant using an automated system. This system first verifies that each control isprogrammed correctly using an interface between the test system and BUS. Next, using the VS1 USB interface and standard firmware, the control is

    commanded to spin a motor. Output speed is verified using external current transducers and the motor is loaded to 150% of rated current. The controlcycles between 150% of rated current and 50% rated current for two minutes. Reversal tests are then run to test the braking transistor and resistorfunctionality. Finally the drive is power cycled, factory defaults are set, and any custom parameters are programmed into the drive. The results of thetest, including the serial numbers of the boards in the control are saved in a database. A shipping label is printed and the control is boxed up ready forshipment. Each control takes about ten minutes to test and up to five controls of varying voltages and sizes can be tested at the same time.

    Alternator Testing

    Alternator testing is performed utilizing a 175KVA test bed. The 175kVA test bed is used in developing new alternator concepts and designs. The alternators aredriven by a Baldor vector motor and vector control. This technology allows for accurate speed regulation, which in turn provides a constant output frequency fromthe alternator under its entire load range. The alternators are loaded using two Avtron load banks. One load bank is a 480V, 500kW resistive load bank and theother is a 480V, 375kVA reactive load bank. A single test panel controls both load banks and monitors load and all other conditions during testing.

    Lubricating Greases TestingTwo test fixtures are used to determine the performance of lubricating greases in ball bearings underloads at high speed and elevated temperatures. The fixtures are capable of speeds up to 10,000 RPMwith 50 pounds of radial loading. Both fixtures have a temperature range from 90F to 500F andthe failure modes are monitored.

    Sound and Vibration

    Sound testing is done in a semi-anechoic sound room. An HP 3569A Acoustic Intensity Analyzerand a precision sound level meter are used in accordance with IEEE Standard 85 to run the soundtests. The isolated seismic pad located in the sound room is used in with a SPS390 and OROS OR36Dynamic Signal Analyzers for no load vibration testing in accordance with NEMA standards.

  • 8/9/2019 AC Ddives Baldor CA769

    11/1167

    Baldor Drives Center

    Test Capabilities

    Fort Smith Test Facilities Features

    Over 32,000 square feet of lab space

    Covered floor trenches provide easy wiring to all areas

    Noise level monitoring equipment notifies technicians whenhearing protection is required

    Dynamometers utilize Baldor Vector Motors and Regen Drives

    Hoists in large dynamometer areas for safe and easy producthandling

    Bus rail power distribution allows for easy power distribution andexpansion

    Short circuit room with 50,000 amps capability for UL testing

    Locked rotor test room for long term locked rotor testing

    Isolation transformers for equipment protection

    Generators provide 50Hz to dynamometer stations

    Isolated seismic pad for vibration testing

    Semi-anechoic sound room

    Network drops throughout labs

    First Responder kits complete with AED

    Fort Smith Test Facilities Accreditations

    UL Certificate of Qualification for Client Test Data Program for UL 508C

    UL Certificate of Qualification for Client Test Data Program for UL 2111

    UL1995 Heat Run

    CSA C390 Certification # EEV-78389

    NVLAP Accreditation for [24/M01] IEEE112, Method B LAB CODE 200537-0

    Fort Smith Test Facilities Major Equipment List

    Power Analyzers

    Digital Oscilloscopes

    Logic Analyzers Inductance Meters

    Distributed Capacitance Meters

    Infrared Camera

    Multimeters and Precision Ohm Meters

    Power Supplies and Hipot Testers

    Fluke Calibrator and other NIST standards

    Data Acquisition Hardware

  • 8/9/2019 AC Ddives Baldor CA769

    12/1168

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Baldor Drives Center

    Test Capabilities

    Test panel design

    Software development

    PCB design and analysis

    Matched Performance

    Application testing

    Motor Plug Reversal

    Training

    Customer site testing

    Thermal development

    Power quality (harmonic) analysis

    EMI and Immunity testing

    Environmental testing

    Audible noise testing Customer witness testing

    Customer requested calibration tests

    Test software design and implementation

    CSA C390

    IEEE 112

    Efficiency testing

    AC and DC Brake Test

    AC and DC no load saturation test

    AC and DC motor heat rise testing

    Working rise at saturation

    Thermal capacity characteristics

    UL and CSA thermal development

    Friction and windage

    Servo viscous damping

    DC motor demagnetization test

    Torque measurement

    Precision resistance measurement

    Sleeve bearing testing

    Sound power level - ANSI S12.12 Vibration level testing in accordance with NEMA MG1 Part 7

    Air flow measurement

    Thermocouple installation

    Rotor data collection

    Brush life testing

    Servo package tests

    Industrial BLDC tests

    Bearing evaluation and life testing

    Fort Smith Test Facilities Major Equipment List

    (cont)

    Burst, EFT and ESD generators

    NSG2025 Surge generator

    Porto-Sag PS-200 Sag/Swell generator

    Chart Recorders

    Two Thermal Chambers (-68C to 170C)

    One Thermal Chamber (-30C to 177C)

    One Thermal and Humidity Chamber (-68C to 177C and 10% to95% RH)

    One HALT/HASS Chamber (-100C to 200C and 0-50grmsrandom vibration)

    Variable AC supplies up to 2000A

    Automated Dynamometers from Fractional to 800HP Continuous(1000HP Intermittent)

    SMT Solder Stations

    Short Circuit Room (50,000 amp short circuit capability)

    Generators for 50Hz Testing

    Test Hoist for Elevator and Hoist Software Development

    Alternator Test Bed up to 175 kVA

    Resistive Load Bank to 500 kW

    Inductive Load Bank to 375 kVA

    Locked Rotor Long Term Life Test Room

    Precision Sound Level Meter

    HP 3569A Acoustic Intensity Analyzer

    OROS OR36 Vibration Analyzer

    SPS390 Dynamic Signal Analyzer

    Semi-Anechoic Room with Seismic Pad

    Bearing Life Test Fixtures

    Video and Digital Photography for Test Documentation

    Fort Smith Test Facilities Scope of Tasks

    Prototyping Design verification tests

    Software verification

    Reliability testing

    Endurance/Life testing

    HALT/HASS testing

    Burst/Surge/Sag/Swell Testing

    UL testing (508C, 2111, 1995)

    Instrument calibration

  • 8/9/2019 AC Ddives Baldor CA769

    13/1169

    Baldor Matched Performance Motors and Drives

    230V, 460V and 600V

    To assist in selection of a Baldor Motor, please find Matched Performance Motor Tables on this page. After selecting your AC Drive in this catalog,please reference the column in the AC Drive Table labeled Matched Performance Motor Code. On the tables below you will find the MatchedPerformance Motor Codes. Simply match the code in the AC Drive Table to the codes in the tables below to select your motor. The following Baldor

    Motors are matched for your convenience:

    Baldor RPMAC Power Dense 1000:1 Inverter Duty Motors

    Baldor RPMAC Power Dense 1000:1 Vector Duty Motors

    Baldor V*S Master TEFC 1000:1 Inverter Duty Motors

    Baldor V*S Master TEFC 1000:1 Vector Duty Motors

    Baldor Inverter Duty TEBC 1000:1 Inverter Duty Motors

    Baldor Inverter Duty TEBC 1000:1 Vector Duty Motors

    Baldor Super-E Premium Efficient Motors

    Matched

    Perf.

    Code

    RPMAC

    Inverter Duty

    1800 RPM

    TENV(1)/TEBC(2)/

    DPG-FV

    1000:1

    RPMAC

    Vector Duty

    1800 RPM

    TENV(1)/TEBC

    1000:1

    V*S Master

    Inverter Duty

    1800 RPM

    TENV(1)/TEFC

    1000:1

    V*S Master

    Vector Duty

    1800 RPM

    TENV(1)/TEFC

    1000:1

    Inverter Duty

    Motor

    1800 RPM

    TENV(1)/TEBC

    1000:1

    Vector Duty

    Motor

    1800 RPM

    TENV(1)/

    TEBC

    1000:1

    Super-E

    Motor

    1800 RPM

    TEFC

    Super-E Motor

    1800 RPM

    TEFC

    Speed Range

    A2 * * IDVSNM3538(1) ZDVSNM3538(1) IDNM3538(1) EM3538 20:01

    B2 * * IDVSNM3546(1) ZDVSNM3546(1) IDNM3581T(1) ZDNM3581T(1) EM3546 20:1

    C2 * * IDVSNM3587T(1) ZDVSN3587T(1) IDM3587T ZDM3587T EM3558 20:1

    D2 * * IDVSM3661T ZDVSM3661T IDM3661T ZDM3661T EM3611T 20:1

    E2 IDNRPM18054C(1) ZDNRPM18054C(1) IDVSM3665T ZDVSM3665T IDM3665T ZDM3665T EM3665T 20:1

    F2 IDNRPM18074C(1) ZDNRPM18074C(1) IDVSM3770T ZDVSM3770T IDM3770T ZDM3770T EM3770T 20:1

    G2 IDNRPM21104C(1) ZDNRPM21104C(1) IDVSM3774T ZDVSM3774T IDM3774T ZDM3774T EM3774T 20:1

    H2 * * IDVSM2333T ZDVSM2333T IDM2333T ZDM2333T EM2333T 10:1I2 * * IDVSM2334T ZDVSM2334T IDM2334T ZDM2334T EM2334T 10:1

    J2 * * IDVSM4103T ZDVSM4103T IDM4103T ZDM4103T EM4103T 10:1

    K2 * * IDVSM4104T ZDVSM4104T IDM4104T ZDM4104T EM4104T 10:1

    L2 * * IDVSM4110T ZDVSM4110T IDM4110T ZDM4110T EM4110T 10:1

    M2 * * IDVSM4115T ZDVSM4115T IDM4115T ZDM4115T EM4115T 10:1

    N2 * * IDVSM4314T ZDVSM4314T EM4314T 4:1

    P2 * * IDVSM4316T ZDVSM4316T EM4316T 4:1

    Q2 * * EM4400T 4:1

    230V Matched Performance Motor Table

    *Custom Motor Available Contact your local Baldor District Office

  • 8/9/2019 AC Ddives Baldor CA769

    14/11610

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    600V Matched Performance Motor Table

    Matched

    Perf.

    Code

    RPMAC

    Inverter Duty

    1800 RPM

    TENV(1)/TEBC(2)/

    DPG-FV

    1000:1

    RPMAC

    Vector Duty

    1800 RPM

    TENV(1)/TEBC

    1000:1

    V*S Master

    Inverter Duty

    1800 RPM

    TENV(1)/TEFC

    1000:1

    V*S Master

    Vector Duty

    1800 RPM

    TENV(1)/TEFC

    1000:1

    Inverter Duty

    Motor

    1800 RPM

    TENV(1)/TEBC

    1000:1

    Vector Duty

    Motor

    1800 RPM

    TENV(1)/

    TEBC

    1000:1

    Super-E Motor

    1800 RPM

    TEFC

    Super-E Motor

    1800 RPM

    TEFC

    Speed Range

    A4 IDVSNM3546(1) ZDVSNM3546(1) IDNM3581T(1) ZDNM3581T(1) EM3546 20:1

    B4 IDVSN3587T(1) ZDVSN3587T(1) IDM3587T ZDM3587T EM3558 20:1

    C4 IDVSM3661T ZDVSM3661T IDM3661T ZDM3661T EM3611T 20:1

    D4 IDNRPM18054C(1) ZDNRPM18054C(1) IDVSM3665T ZDVSM3665T IDM3665T ZDM3665T EM3665T 20:1

    E4 IDNRPM18074C(1) ZDNRPM18074C(1) IDVSM3770T ZDVSM3770T IDM3770T ZDM3770T EM3770T 20:1

    F4 IDNRPM21104C(1) ZDNRPM21104C(1) IDVSM3774T ZDVSM3774T IDM3774T ZDM3774T EM3774T 20:1

    G4 IDBRPM18154C(2) ZDBRPM18154C IDVSM2333T ZDVSM2333T IDM2333T ZDM2333T EM2333T 10:1

    H4 IDBRPM18204C(2) ZDBRPM18204C IDVSM2334T ZDVSM2334T IDM2334T ZDM2334T EM2334T 10:1

    I4 IDDRPM18254C ZDFRPM21254C IDVSM4103T ZDVSM4103T IDM4103T ZDM4103T EM4103T 10:1

    J4 IDDRPM18304C ZDBRPM21304C IDVSM4104T ZDVSM4104T IDM4104T ZDM4104T EM4104T 10:1

    K4 IDDRPM21404 ZDBRPM21404 IDVSM4110T ZDVSM4110T IDM4110T ZDM4110T EM4110T 10:1

    L4 IDDRPM21504 ZDBRPM25504 IDVSM4115T ZDVSM4115T IDM4115T ZDM4115T EM4115T 10:1

    M4 IDDRPM21604 ZDBRPM25604 IDVSM4314T ZDVSM4314T EM4314T 4:1N4 IDDRPM25754 ZDBRPM25754 IDVSM4316T ZDVSM4316T EM4316T 4:1

    P4 IDDRPM251004 ZDBRPM281004R1 IDVSM4400T-4 ZDVSM4400T-4 EM4400T 4:1

    Q4 IDDRPM251254 ZDBRPM281254 IDVSM4410T-4 ZDVSM4410T-4 EM4410T-4 4:1

    R4 IDDRPM281504 ZDBRPM321504 IDVSM4406T-4 ZDVSM4406T-4 EM4406T-4 4:1

    S4 IDDRPM282004 ZDBRPM362004 IDVSM4407T-4 ZDVSM4407T-4 EM4407T-4 4:1

    T4 IDDRPM322504 IDVSM4408T-4 ZDVSM4408T-4 M4408T-4 2:1

    U4 IDDRPM323004 IDVSM44304T-4 ZDVSM44304T-4 M44304T-4 2:1

    V4 IDDRPM363504 M44354T-4 2:1

    W4 IDDRPM364004 M44404T-4 2:1

    X4 IDDRPM405004

    Y4 IDDRPM406004

    Matched

    Perf.

    Code

    RPMAC

    Inverter Duty

    1800 RPM

    TENV(1)/TEBC(2)/

    DPG-FV

    1000:1

    RPMAC

    Vector Duty

    1800 RPM

    TENV(1)/TEBC

    1000:1

    V*S Master

    Inverter Duty

    1800 RPM

    TENV(1)/TEFC

    1000:1

    V*S Master

    Vector Duty

    1800 RPM

    TENV(1)/TEFC

    1000:1

    Inverter Duty

    Motor

    1800 RPM

    TEBC

    1000:1

    Vector Duty

    Motor

    1800 RPM

    TENV(1)/TEBC

    1000:1

    Super-E Motor

    1800 RPM

    TEFC

    Super-E Motor

    1800 RPM

    TEFC

    Speed Range

    A5 * * * * IDM3581T-5 ZDM3581T-5 ECP3581T-5 20:1

    B5 * * * * IDM3587T-5 ZDM3587T-5 ECP3587T-5 20:1

    C5 * * * * IDM3661T-5 ZDM3661T-5 ECP3611T-5 20:1

    D5 * * * * IDM3665T-5 ZDM3665T-5 ECP3665T-5 20:1

    E5 * * * * IDM3770T-5 ZDM3770T-5 ECP3770T-5 20:1

    F5 * * * * IDM3774T-5 ZDM3774T-5 ECP3774T-5 20:1

    G5 * * * * IDM2333T-5 ZDM2333T-5 ECP2333T-5 10:1

    H5 * * * * IDM2334T-5 ZDM2334T-5 ECP2334T-5 10:1I5 * * * * ECP4103T-5 10:1

    J5 * * * * ECP4104T-5 10:1

    K5 * * * * ECP4110T-5 10:1

    L5 * * * * ECP4115T-5 10:1

    M5 * * * * ECP4314T5 4:1

    N5 * * * * ECP4316T-5 4:1

    P5 * * * * ECP4400T-5 4:1

    Q5 * * * * ECP4410T-5 4:1

    R5 * * * * ECP4406T-5 4:1

    *Custom Motor Available Contact your local Baldor District Office

    Baldor Matched Performance Motors and Drives

    460V Matched Performance Motor Table

  • 8/9/2019 AC Ddives Baldor CA769

    15/11611

    Applications:Variable torque, constant torque or constant horsepower applications. Newinstallations, replacements and original equipment manufactures (OEM).

    Features:Volts per Hertz Control with peak overload capacity of 175% and PI capability.Flexible mounting options with IP20 enclosure as standard and DIN Rail

    mounting.Integral keypad, operator interface and local speed control. Basic set ofprogramming parameters. Power ratings up to 5 Hp at 230V and 15 Hp at 460V versions.

    VS1ST

    AC Micro Drive

    1/2 thru 1.5 Hp1/2 thru 3 Hp1/2 thru 5 Hp1 thru 15 Hp

    115 VAC230 VAC230 VAC460 VAC

    1 Phase - 50/60 Hz1 Phase - 50/60 Hz3 Phase - 50/60 Hz3 Phase - 50/60 Hz

    Performance Features Control Modes V/HzOperator Inter face Module Integral Drive MountedDisplay Lines 6-Character LED DisplayProgrammable Preset Speeds FourAnalog Outputs One (0-10 VDC)

    Auto Restart Yes Up to 5 attemptsFrequency Avoidance One BandFault History Last Four FaultsDigital Inputs: Four Two Programmable Digital Inputs, Two user selectable analog/digital inputsDigital Inputs Type Pull-Up

    Drive Specifications Analog Inputs: Two 0-10VDC, 0 to 20mA or 4 to 20mARelay Outputs: One Built-in Form C RelayAnalog Output/Digital Output 0-10 VDC: One Analog Usable for Meter (Freq., Current, Voltage) or Digital OutputMaximum Load 15 Hp @ 460 VACOverload Capacity Drive Output 150% for one minute and 175% for 2 secondsInput Voltage Ranges 115 VAC (99-126); 230 VAC (198-264); 460 VAC (342-528)Rated Input Frequency 50-60Hz (5%)Carrier Frequency 4-32 kHz (8 kHz default)Operating Temperature 0 to 50CSnubber (Dynamic Braking) Built-in Transistor (Frames B & C)

    Dynamic Braking External Up to 150% Dynamic Braking with appropriately sized resistorDC Injection Braking IncludedVolts/Hz Linear V/Hz, Energy Optimizer FunctionFrequency Control Range 0 - 500HzAccel/Decel: Independently adjustable accel. & decel. rampsTime Range: 0 to 600 SecondsKeypad Speed Control YesSink/Source Inputs Selectable, 24 VDC LogicElectronic Overload Trip Electronic Motor Overload Inverse 150% for 1 minute or 175% for 2 secondsCommunications Built-in MODBUS-RTU (RS-485) Communications; Gateways, DeviceNet, Profibus-DP, Ethernet/IP, Modbus/TCPPI Control Built-in

    Protective Features Under Voltage Level Depends on Voltage Class (240, 480, or 575)Output Short Circuit Phase-to-Phase on Drive OutputOver Temperature Heatsink MonitorDC Bus Overvoltage DC Bus Level Trip

    Drive Overload Exceed Drive rating of 150% for One Minute or 175% for 2 secondsOver Current Over-current/short-Circuit protectionOutput Phase Trips on open Output PhaseLoss of Reference Trips on Loss of Speed Command SignalComm. Error Detects a communication error (fault)

    Agency Certifications UL, cUL, CE, C-tickService Conditions Altitude 1,000 m (3,300 ft.), derate by 1% per 100m up to 2,000 on maximum.

    Ambient Temperature IP20: -10C (14F) to 50C (122F)Storage Temperature -40C (-40F) to 60C (140F)Relative Humidity 10% to 95%, non-condensing

  • 8/9/2019 AC Ddives Baldor CA769

    16/11612

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    VS1ST 115V, 50/60 Hz, 1-Phase Input (230V, 3-Phase Output)

    Catalog Number EMC Filter Transistor Frame HpOutput

    Current

    Matched Perf.

    Motor CodeList Price Mult. Sym.

    VS1ST10P5-0 No No A 0.5 2.3 A2 453 EA

    VS1ST11-0 No No A 1 4.3 B2 529 EA

    VS1ST11P5-0T No Yes B 1.5 5.8 C2 649 EA

    VS1ST 230V, 50/60 Hz, 1-Phase Input (230V, 3-Phase Output)

    Catalog Number EMC Filter Transistor Frame HpOutput

    Current

    Matched Perf.

    Motor CodeList Price Mult. Sym.

    VS1ST80P5-0 No No A 0.5 2.3 A2 364 EA

    VS1ST80P5-0F Yes No A 0.5 2.3 A2 383 EA

    VS1ST81-0 No No A 1 4.3 B2 395 EA

    VS1ST81-0F Yes No A 1 4.3 B2 488 EA

    VS1ST82-0 No No A 2 7 C2 475 EA

    VS1ST82-0F Yes No A 2 7 C2 626 EA

    VS1ST82-0T No Yes B 2 7 C2 592 EA

    VS1ST82-0TF Yes Yes B 2 7 C2 707 EA

    VS1ST83-0T No Yes B 3 10.5 D2 661 EA

    VS1ST83-0TF Yes Yes B 3 10.5 D2 829 EA

    VS1ST 230V, 50/60 Hz, 3-Phase Input (230V, 3-Phase Output)

    Catalog Number EMC Filter Transistor Frame HpOutput

    Current

    Matched Perf.

    Motor CodeList Price Mult. Sym.

    VS1ST20P5-0 No No A 0.5 2.3 A2 364 EA

    VS1ST21-0 No No A 1 4.3 B2 395 EA

    VS1ST22-0 No No A 2 7 C2 475 EA

    VS1ST22-0T No Yes B 2 7 C2 556 EA

    VS1ST22-0TF Yes Yes B 2 7 C2 592 EA

    VS1ST23-0T No Yes B 3 10.5 D2 568 EA

    VS1ST23-0TF Yes Yes B 3 10.5 D2 661 EA

    VS1ST25-0T No Yes C 5 18 E2 752 EA

    VS1ST25-0TF Yes Yes C 5 18 E2 939 EA

    VS1ST 460V, 50/60 Hz, 3-Phase Input (460V, 3-Phase Output)

    Catalog Number EMC Filter Transistor Frame HpOutput

    Current

    Matched Perf.

    Motor CodeList Price Mult. Sym.

    VS1ST41-0 No No A 1 2.2 A4 475 EA

    VS1ST41-0F Yes No A 1 2.2 A4 533 EA

    VS1ST42-0 No No A 2 4.1 B4 557 EA

    VS1ST42-0F Yes No A 2 4.1 B4 614 EA

    VS1ST42-0T No Yes B 2 4.1 B4 637 EA

    VS1ST42-0TF Yes Yes B 2 4.1 B4 684 EA

    VS1ST43-0T No Yes B 3 5.8 C4 684 EA

    VS1ST43-0TF Yes Yes B 3 5.8 C4 742 EA VS1ST45-0T No Yes B 5 9.5 D4 800 EA

    VS1ST45-0TF Yes Yes B 5 9.5 D4 857 EA

    VS1ST47-0T No Yes C 7.5 14 E4/F4 1,135 EA

    VS1ST47-0TF Yes Yes C 7.5 14 E4/F4 1,193 EA

    VS1ST410-0T No Yes C 10 18 F4 1,263 EA

    VS1ST410-0TF Yes Yes C 10 18 F4 1,356 EA

    VS1ST415-0T No Yes C 15 24 G4 1,704 EA

    VS1ST415-0TF Yes Yes C 15 24 G4 1,828 EA

    Stock Model Numbers

  • 8/9/2019 AC Ddives Baldor CA769

    17/11613

    Dimensions

    FrameHeight

    Inches (mm)

    Width

    Inches (mm)

    Depth

    Inches (mm)

    A 6.81 (173) 3.23 (82) 4.84 (123)

    B 8.70 (221) 4.29 (109) 5.91 (150)

    C 10.28 (261) 5.16 (131) 6.89 (175)

    VS1ST AC Micro Drive

  • 8/9/2019 AC Ddives Baldor CA769

    18/11614

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Product Highlights: The VS1STS is a feature rich V/Hz & Sensorless Vectorproduct targeted at the 600V market and equipment manufacturing applications.

    Applications:Variable torque, constant torque or constant horsepower applications.New installations, replacements and original equipment manufactures (OEM).

    Features:V/Hz and Sensorless Vector Control with peak overload capacity of 175%and PID capability. Flexible mounting options with IP20 enclosure as standard andDIN rail capability. Integral keypad, operator interface and local speed control. Basicsetup parameter list and advanced software settings. Built-in braking transistorallows connection to remote braking resistor for enhanced performance needs.Power ratings up to 60 Hp at 600V, pluggable I/O terminal strip.

    VS1STS

    600V Starter Style

    AC Micro Drive

    1 thru 60 Hp 500-600 VAC 3 Phase - 50/60 Hz

    Performance Features Control Modes V/Hz & Sensorless Vector Control

    Operator Interface Module Integral Drive Mounted; basic start/stop, forward/reverse and speed controlDisplay Lines 6-Character LED DisplayProgrammable Preset Speeds EightAnalog Output: One 0-10VDC or 20mA

    Auto Restart Yes -- Up to 5 attemptsFrequency Avoidance One BandFault History Last four faultsDigital Inputs: Four Two programmable digi tal inputs, two user selectable analog/digital inputsDigital Inputs Type Pull-Up

    Drive Specifications Analog Inputs: Two One bi-polar and one 0-10VDC, 0 to 20mA or 4 to 20mARelay Output: One Built-in Form C Relay, normally open contact

    Analog Output/Digital: One 0-10 VDC: One Analog Usable for Meter (Freq., Current, Voltage) or Digital OutputMaximum Load: 60 HP @ 600 VACOverload Capacity Drive Output 150% for one minute and 175% for 2 secondsInput Voltage Ranges: 500 - 600VACInput Voltage Tolerance 10% / -10%Rated Input Frequency 50-60Hz (5%)

    Carrier Frequency: 4-32 kHz (8 kHz default)Operating Temperature: -10 to 50CSnubber (Dynamic Braking): Buil t- in TransistorDynamic Braking External: Up to 150% Dynamic Braking with appropriately sized resistorDC Injection Braking: IncludedVolts/Hz Linear V/Hz

    Energy Optimization FunctionSensorless Vector Full Sensorless Vector Control with Autotune and motor modelFrequency Control Range: 0 - 2000HzAccel/Decel: Independently adjustable accel. & decel. rampsKeypad Speed Control YesSink/Source Inputs Selectable, 24 VDC Logic

    Electronic Overload Trip Electronic Motor Overload Inverse 150% for 1 minute or 175% for 2 secondsProtective Features Under Voltage Level Depends on Voltage Class (600V)

    Output Short Circuit Phase-to-Phase on Drive OutputOver Temperature Heatsink Monitor

    DC Bus Overvoltage DC Bus Level TripDrive Overload Exceed Drive rating of 150% for One Minute or 175% for 2 secondsOver Current Over-current/short-Circuit protectionOutput Phase Trips on open Output PhaseLoss of Reference Trips on Loss of Speed Command SignalCommunication Error Detects a communication error (fault)

    Agency Certifications UL, cUL, CE, CCC, C-tickService Conditions Altitude: 1,000 m (3,300 ft.) Maximum

    Ambient Temperature: IP20: -10C to 50CStorage Temperature: -20C to 60CRelative Humidity: 10% to 90%, non-condensingIntermittent Overload: 150% overload capacity for up to 1 minute

    175% overload capacity for up to 2 seconds

  • 8/9/2019 AC Ddives Baldor CA769

    19/11615

    VS1STS 500-600V 10% 3-Phase Input

    Catalog Number Frame Hp kW Output CurrentMatched Perf.

    Motor CodeList Price Mult. Sym.

    VS1STS51-0T B 1 0.75 1.7 A5 926 EA

    VS1STS52-0T B 2 1.5 3.1 B5 1,042 EA

    VS1STS53-0T B 3 2.2 4.1 C5 1,158 EA

    VS1STS55-0T B 5 4 6.1 D5 1,390 EA VS1STS57-0T B 7.5 5.5 9 E5 1,737 EA

    VS1STS510-0T C 10 7.5 14 F5 2,084 EA

    VS1STS515-0T C 15 11 18 G5 2,546 EA

    VS1STS520-0T C 20 15 24 H5/J5 3,241 EA

    VS1STS530-0T D 30 22 39 J5/K5 5,093 EA

    VS1STS540-0T D 40 30 46 L5 5,787 EA

    VS1STS560-0T D 60 45 62 M5 6,944 EA

    Dimensions

    FrameHeight

    Inches (mm)

    Width

    Inches (mm)

    Depth

    Inches (mm)A 10.24 (260) 3.94 (100) 6.89 (175)

    B 10.24 (260) 6.73 (171) 6.89 (175)

    C 20.47 (520) 13.39 (340) 8.66 (220)

    Stock Model Numbers

  • 8/9/2019 AC Ddives Baldor CA769

    20/11616

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Applications:Applications that require a washdown or harsh duty enclosure. Ideal forenvironments where dust, oil mist or water is prevalent. Variable torque, constant torque orconstant horsepower applications. Target stand alone applications where a local disconnect isrequired. New installations, replacements and original equipment manufactures (OEM).

    Features:Volts per Hertz Control with peak overload capacity of 175%. Flexible mountingoptions NEMA 12, NEMA 4X Indoor only, Input Disconnect models and EMC Filter models.Integral keypad, operator interface and local speed control. Speed potentiometer and F-O-Rswitch on input disconnect models only. Basic set of less than forty programming parameters.Power ratings up to 10 Hp in 460V versions.

    VS1MX

    AC Micro Drive

    1/2 thru 1.5 Hp1/2 thru 3 Hp1/2 thru 5 Hp1 thru 10 Hp

    115 VAC230 VAC230 VAC460 VAC

    1 Phase - 50/60 Hz1 Phase - 50/60 Hz3 Phase - 50/60 Hz3 Phase - 50/60 Hz

    Performance Features Control Modes V/HzOperator Interface Module Integral Drive MountedDisplay Lines 6-Character LED DisplayProgrammable Preset Speeds FourAnalog Outputs One (0-10 VDC)Auto Restart Yes Up to 5 attemptsFrequency Avoidance One BandFault History Last Four FaultsDigital Inputs Three Configurable InputsDigital Inputs Type Pull-Up

    Drive Specifications Analog Inputs: Two 0-10VDC, 4 to 20mARelay Outputs: One One Built-in Form C RelayAnalog Output / Digital Output 0-10 VDC: One Analog Usable for Meter (Freq., Current, Voltage) or Digital OutputMaximum Load 10 Hp @ 460 VACOverload Capacity Drive Output 150% for one minute and 175% for 2 secondsInput Voltage Ranges 115 VAC (99-126); 230 VAC (198-264); 460 VAC (342-528)Rated Input Frequency 50-60Hz (5%)Carrier Frequency 4-32 kHz (8 kHz default)Operating Temperature 10 to 40C

    Snubber (Dynamic Braking) Built-in Transistor (Frames B and C)Dynamic Braking External Up to 150% Dynamic Braking with appropriately sized resistorDC Injection Braking IncludedVolts/Hz Linear V/Hz, Energy Optimizer FunctionFrequency Control Range 0 - 500HzAccel/Decel Independently adjustable accel. & decel. rampsTime Range 0.1 to 600.0 SecondsKeypad Speed Control YesSink/Source Inputs Selectable, 24 VDC LogicElectronic Overload Trip Electronic Motor Overload Inverse 150% for 1 minute or 175% for 2 secondsCommunications Built-in MODBUS-RTU (RS-485) Communications; Gateways, DeviceNet, Profibus-DP, Ethernet/IP, Modbus/TCPPI Control Built-in

    Protective Features Under Voltage Level Depends on Voltage Class (240, 480, or 575)Output Short Circuit Phase-to-Phase on Drive OutputOver Temperature Heatsink Monitor

    DC Bus Overvoltage DC Bus Level TripDrive Overload Exceed Drive rating of 150% for One Minute or 175% for 2 secondsOver Current Over-current/short-Circuit protectionOutput Phase Trips on open Output PhaseLoss of Reference Trips on Loss of Speed Command SignalComm. Error Detects a communication error (fault)

    Agency Certifications UL, cUL, CE, CCC, C-tickService Conditions Altitude 1,000 m (3,300 ft.), derate by 1% per 100m up to 2,000m maximum

    Ambient Temperature -10C (14F) to 40C (102F)Storage Temperature -40C (-40F) to 60C (140F)Relative Humidity 10% to 95%, non-condensingIntermittent Overload 150% overload capacity for up to 1 minute, 175% overload capacity for up to 2 seconds

  • 8/9/2019 AC Ddives Baldor CA769

    21/11617

    VS1MX 115V, 50/60 Hz, 1-Phase Input (230V, 3-Phase Output) NEMA 4X/12** (White Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor CodeList Price Mult. Sym.

    VS1MX10P5-4 No No A 0.5 2.3 A2 701 EA

    VS1MX10P5-4D No Yes A 0.5 2.3 A2 770 EA

    VS1MX11-4No No A 1 4.3 B2 726 EA

    VS1MX11-4D No Yes A 1 4.3 B2 800 EA

    VS1MX11P5-4T No No B 1.5 5.8 C2 910 EA

    VS1MX11P5-4TD No Yes B 1.5 5.8 C2 1,000 EA

    VS1MX 115V, 50/60 Hz, 1-Phase Input (230V, 3-Phase Output) NEMA 12 (Green Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor CodeList Price Mult. Sym.

    VS1MX10P5-2 No No A 0.5 2.3 A2 644 EA

    VS1MX10P5-2D No Yes A 0.5 2.3 A2 708 EA

    VS1MX11-2 No No A 1 4.3 B2 669 EA

    VS1MX11-2D No Yes A 1 4.3 B2 736 EA

    VS1MX11P5-2T No No B 1.5 5.8 C2 837 EA

    VS1MX11P5-2TD No Yes B 1.5 5.8 C2 920 EA

    VS1MX 230V, 50/60 Hz, 1-Phase Input (230V, 3-Phase Output) NEMA 4X/12** (White Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor CodeList Price Mult. Sym.

    VS1MX80P5-4 No No A 0.5 2.3 A2 609 EA

    VS1MX80P5-4F Yes No A 0.5 2.3 A2 670 EA

    VS1MX80P5-4D No Yes A 0.5 2.3 A2 670 EA

    VS1MX80P5-4DF Yes Yes A 0.5 2.3 A2 737 EA

    VS1MX81-4 No No A 1 4.3 B2 695 EA

    VS1MX81-4F Yes No A 1 4.3 B2 695 EA VS1MX81-4D No Yes A 1 4.3 B2 695 EA

    VS1MX81-4DF Yes Yes A 1 4.3 B2 765 EA

    VS1MX82-4 No No A 2 7 C2 790 EA

    VS1MX82-4F Yes No A 2 7 C2 870 EA

    VS1MX82-4D No Yes A 2 7 C2 870 EA

    VS1MX82-4DF Yes Yes A 2 7 C2 957 EA

    VS1MX82-4T No No B 2 7 C2 879 EA

    VS1MX82-4TF Yes No B 2 7 C2 966 EA

    VS1MX82-4TD No Yes B 2 7 C2 966 EA

    VS1MX82-4TDF Yes Yes B 2 7 C2 1,063 EA

    VS1MX83-4T No No B 3 10.5 D2 913 EA

    VS1MX83-4TF Yes No B 3 10.5 D2 1,002 EA

    VS1MX83-4TD No Yes B 3 10.5 D2 1,002 EAVS1MX83-4TDF Yes Yes B 3 10.5 D2 1,102 EA

    Stock Model Numbers

    * Disconnect models include speed potentiometer and F-O-R switch

    ** Indoor

  • 8/9/2019 AC Ddives Baldor CA769

    22/11618

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    VS1MX 230V, 50/60 Hz, 1-Phase Input (230V, 3-Phase Output) NEMA 12 (Green Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor CodeList Price Mult. Sym.

    VS1MX80P5-2 No No A 0.5 2.3 A2 560 EA

    VS1MX80P5-2F Yes No A 0.5 2.3 A2 616 EA

    VS1MX80P5-2D No Yes A 0.5 2.3 A2 616 EA

    VS1MX80P5-2DF Yes Yes A 0.5 2.3 A2 677 EA

    VS1MX81-2 No No A 1 4.3 B2 582 EA

    VS1MX81-2F Yes No A 1 4.3 B2 640 EA

    VS1MX81-2D No Yes A 1 4.3 B2 640 EA

    VS1MX81-2DF Yes Yes A 1 4.3 B2 704 EA

    VS1MX82-2 No No A 2 7 C2 728 EA

    VS1MX82-2F Yes No A 2 7 C2 801 EA

    VS1MX82-2D No Yes A 2 7 C2 781 EA

    VS1MX82-2DF Yes Yes A 2 7 C2 881 EA

    VS1MX82-2T No No B 2 7 C2 808 EA

    VS1MX82-2TF Yes No B 2 7 C2 889 EA

    VS1MX82-2TD No Yes B 2 7 C2 889 EA

    VS1MX82-2TDF Yes Yes B 2 7 C2 979 EA

    VS1MX83-2T No No B 3 10.5 D2 840 EAVS1MX83-2TF Yes No B 3 10.5 D2 923 EA

    VS1MX83-2TD No Yes B 3 10.5 D2 923 EA

    VS1MX83-2TDF Yes Yes B 3 10.5 D2 1,015 EA

    VS1MX 230V, 50/60 Hz, 3-Phase Input (230V, 3-Phase Output) NEMA 4X/12** (White Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor Code List Price Mult. Sym.

    VS1MX20P5-4 No No A 0.5 2.3 A2 626 EA

    VS1MX20P5-4D No Yes A 0.5 2.3 A2 688 EA

    VS1MX21-4 No No A 1 4.3 B2 688 EA

    VS1MX21-4D No Yes A 1 4.3 B2 711 EA VS1MX22-4 No No A 2 7 C2 712 EA

    VS1MX22-4D No Yes A 2 7 C2 783 EA

    VS1MX22-4T No No B 2 7 C2 791 EA

    VS1MX22-4TF Yes No B 2 7 C2 783 EA

    VS1MX22-4TD No Yes B 2 7 C2 870 EA

    VS1MX22-4TDF Yes Yes B 2 7 C2 861 EA

    VS1MX23-4T No No B 3 10.5 D2 821 EA

    VS1MX23-4TF Yes No B 3 10.5 D2 903 EA

    VS1MX23-4TD No Yes B 3 10.5 D2 903 EA

    VS1MX23-4TDF Yes Yes B 3 10.5 D2 993 EA

    VS1MX25-4T No No C 5 18 E2 1,170 EA

    VS1MX25-4TF Yes No C 5 18 E2 1,288 EA

    VS1MX25-4TD No Yes C 5 18 E2 1,288 EAVS1MX25-4TDF Yes Yes C 5 18 E2 1,416 EA

    Stock Model Numbers

    * Disconnect models include speed potentiometer and F-O-R switch

    ** Indoor

  • 8/9/2019 AC Ddives Baldor CA769

    23/11619

    VS1MX 230V, 50/60 Hz, 3-Phase Input (230V, 3-Phase Output) NEMA 12 (Green Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor Code List Price Mult. Sym.

    VS1MX20P5-2 No No A 0.5 2.3 A2 574 EA

    VS1MX20P5-2D No Yes A 0.5 2.3 A2 632 EA

    VS1MX21-2 No No A 1 4.3 B2 596 EA

    VS1MX21-2D No Yes A 1 4.3 B2 655 EA

    VS1MX22-2 No No A 2 7 C2 654 EA

    VS1MX22-2D No Yes A 2 7 C2 720 EA

    VS1MX22-2T No No B 2 7 C2 728 EA

    VS1MX22-2TF Yes No B 2 7 C2 720 EA

    VS1MX22-2TD No Yes B 2 7 C2 800 EA

    VS1MX22-2TDF Yes Yes B 2 7 C2 792 EA

    VS1MX23-2T No No B 3 10.5 D2 755 EA

    VS1MX23-2TF Yes No B 3 10.5 D2 831 EA

    VS1MX23-2TD No Yes B 3 10.5 D2 831 EA

    VS1MX23-2TDF Yes Yes B 3 10.5 D2 914 EA

    VS1MX 460V, 50/60 Hz, 3-Phase Input (460V, 3-Phase Output) NEMA 4X/12** (White Enclosure)

    Catalog Number EMC Filter Disconnect* Frame Hp Output CurrentMatched Perf.

    Motor Code List Price Mult. Sym.

    VS1MX41-4 No No A 1 2.2 A4 762 EA

    VS1MX41-4F Yes No A 1 2.2 A4 838 EA

    VS1MX41-4D No Yes A 1 2.2 A4 838 EA

    VS1MX41-4DF Yes Yes A 1 2.2 A4 921 EA

    VS1MX42-4 No No A 2 4.1 B4 920 EA

    VS1MX42-4F Yes No A 2 4.1 B4 1,013 EA

    VS1MX42-4D No Yes A 2 4.1 B4 1,013 EA

    VS1MX42-4DF Yes Yes A 2 4.1 B4 1,114 EA

    VS1MX42-4T No No B 2 4.1 B4 1,022 EA

    VS1MX42-4TF Yes No B 2 4.1 B4 1,125 EA VS1MX42-4TD No Yes B 2 4.1 B4 1,125 EA

    VS1MX42-4TDF Yes Yes B 2 4.1 B4 1,237 EA

    VS1MX43-4T No No B 3 5.8 C4 1,065 EA

    VS1MX43-4TF Yes No B 3 5.8 C4 1,170 EA

    VS1MX43-4TD No Yes B 3 5.8 C4 1,170 EA

    VS1MX43-4TDF Yes Yes B 3 5.8 C4 1,288 EA

    VS1MX45-4T No No B 5 9.5 D4 1,323 EA

    VS1MX45-4TF Yes No B 5 9.5 D4 1,456 EA

    VS1MX45-4TD No Yes B 5 9.5 D4 1,458 EA

    VS1MX45-4TDF Yes Yes B 5 9.5 D4 1,600 EA

    VS1MX47-4T No No C 7.5 14 E4/F4 1,708 EA

    VS1MX47-4TF Yes No C 7.5 14 E4/F4 1,879 EA

    VS1MX47-4TD No Yes C 7.5 14 E4/F4 1,879 EAVS1MX47-4TDF Yes Yes C 7.5 14 E4/F4 2,065 EA

    VS1MX410-4T No No C 10 18 F4 2,025 EA

    VS1MX410-4TF Yes No C 10 18 F4 2,228 EA

    VS1MX410-4TD No Yes C 10 18 F4 2,228 EA

    VS1MX410-4TDF Yes Yes C 10 18 F4 2,450 EA

    Stock Model Numbers

    * Disconnect models include speed potentiometer and F-O-R switch

    ** Indoor

  • 8/9/2019 AC Ddives Baldor CA769

    24/11620

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    VS1MX 460V, 50/60 Hz, 3-Phase Input (460V, 3-Phase Output) NEMA 12 (Green Enclosure)

    Catalog Number EMC Filter Disconnect* Frame HpOutput

    Current

    Matched Perf.

    Motor CodeList Mult. Sym.

    VS1MX41-2 No No A 1 2.2 A4 701 EA

    VS1MX41-2F Yes No A 1 2.2 A4 770 EA

    VS1MX41-2D No Yes A 1 2.2 A4 770 EA

    VS1MX41-2DF Yes Yes A 1 2.2 A4 847 EA

    VS1MX42-2 No No A 2 4.1 B4 846 EA

    VS1MX42-2F Yes No A 2 4.1 B4 931 EA

    VS1MX42-2D No Yes A 2 4.1 B4 931 EA

    VS1MX42-2DF Yes Yes A 2 4.1 B4 1,024 EA

    VS1MX42-2T No No B 2 4.1 B4 940 EA

    VS1MX42-2TF Yes No B 2 4.1 B4 1,034 EA

    VS1MX42-2TD No Yes B 2 4.1 B4 1,034 EA

    VS1MX42-2TDF Yes Yes B 2 4.1 B4 1,138 EA

    VS1MX43-2T No No B 3 5.8 C4 979 EA

    VS1MX43-2TF Yes No B 3 5.8 C4 1,077 EA

    VS1MX43-2TD No Yes B 3 5.8 C4 1,077 EA

    VS1MX43-2TDF Yes Yes B 3 5.8 C4 1,185 EA VS1MX45-2T No No B 5 9.5 D4 1,217 EA

    VS1MX45-2TF Yes No B 5 9.5 D4 1,339 EA

    VS1MX45-2TD No Yes B 5 9.5 D4 1,339 EA

    VS1MX45-2TDF Yes Yes B 5 9.5 D4 1,473 EA

    Stock Model Numbers

    * Disconnect models include speed potentiometer and F-O-R switch

    Dimensions - NEMA 12 (IP55)

    FrameHeight

    Inches (mm)

    Width

    Inches (mm)

    Depth

    Inches (mm)

    A 7.87 (200) 5.51 (140) 6.54 (166)

    B 12.2 (310) 6.5 (165) 7.09 (180)

    Dimensions - NEMA 4X (IP66)

    FrameHeight

    Inches (mm)

    Width

    Inches (mm)

    Depth

    Inches (mm)

    A 9.13 (232) 6.34 (161) 6.89 (175)

    B 10.12 (257) 7.40 (178) 7.30 (185.5)

    C 12.01 (305) 8.29 (210.5) 8.97 (227.8)

  • 8/9/2019 AC Ddives Baldor CA769

    25/11621

    Product Highlights: The VS1MXS is a feature rich V/Hz & Sensorless Vectorproduct targeted at the 600V market and harsh duty applications.

    Applications:Variable torque, constant torque or constant horsepowerapplications. New installations, replacements and original equipment manufactures

    (OEM).Features:V/Hz and Sensorless Vector Control with peak overload capacityof 175% and PID capability. Flexible mounting options with IP55 (NEMA 12)enclosure as standard. Integral keypad, operator interface and local speed control.Speed potentiometer and F-O-R switch on input disconnect models only. Basicsetup parameter list and advanced software settings. Built-in braking transistorallows connection to remote braking resistor for enhanced performance needs.Power ratings up to 7.5 HP at 600V, pluggable I/O terminal strip.

    VS1MXS

    600V Harsh Duty

    AC Micro Drive

    1 thru 7.5 Hp 500-600 VAC 3 Phase - 50/60 Hz

    Performance Features Control Modes V/Hz & Sensorless Vector ControlOperator Interface Module Integral Drive Mounted; basic start/stop, forward/reverse and speed controlDisplay Lines 6-Character LED DisplayProgrammable Preset Speeds EightAnalog Output: One 0-10VDC or 20mA

    Auto Restart Yes -- Up to 5 attemptsFrequency Avoidance One BandFault History Last four faultsDigital Inputs: Four Two programmable digi tal inputs, two user selectable analog/digi tal inputsDigital Inputs Type Pull-Up

    Drive Specifications Analog Inputs: Two One bi-polar and one 0-10VDC, 0 to 20mA or 4 to 20mARelay Output: One Built-in Form C Relay, normally open contact

    Analog Output/Digital: One 0-10 VDC: One Analog Usable for Meter (Freq., Current, Voltage) or Digital OutputMaximum Load: 7.5 HP @ 600 VACOverload Capacity Drive Output 150% for one minute and 175% for 2 secondsInput Voltage Ranges 500 - 600VACInput Voltage Tolerance 10% / -10%Rated Input Frequency 50-60Hz (5%)

    Carrier Frequency 4-32 kHz (8 kHz default)Operating Temperature -10 to 50C

    Snubber (Dynamic Braking) Built-in TransistorDynamic Braking External Up to 150% Dynamic Braking with appropriately sized resistorDC Injection Braking Included

    Volts/Hz Linear V/Hz, Energy Optimization FunctionSensorless Vector Full Sensorless Vector Control with Autotune and motor modelFrequency Control Range 0 - 2000HzAccel/Decel: Independently adjustable accel. & decel. rampsKeypad Speed Control YesSink/Source Inputs Selectable, 24 VDC Logic

    Electronic Overload Trip Electronic Motor Overload Inverse 150% for 1 minute or 175% for 2 secondsCommunications Built-in MODBUS-RTU (RS-485) Communications, RJ11 connection; Gateways, DeviceNet, Profibus-DP,

    Ethernet/IP, Modbus/TCPPID Control Built-in with sleep/wake function

    Protective Features Under Voltage Level Depends on Voltage Class (600V)

    Output Short Circuit Phase-to-Phase on Drive OutputOver Temperature Heatsink MonitorDC Bus Overvoltage DC Bus Level TripDrive Overload Exceed Drive rating of 150% for One Minute or 175% for 2 secondsOver Current Over-current/short-Circuit protectionOutput Phase Trips on open Output Phase

    Loss of Reference Trips on Loss of Speed Command SignalCommunication Error Detects a communication error (fault)

    Agency Certifications UL, cUL, CE, CCC, C-tickService Conditions Altitude 1,000 m (3,300 ft.) Maximum

    Ambient Temperature -10C to 50CStorage Temperature: -20C to 60C

    Relative Humidity 10% to 90%, non-condensingIntermittent Overload 150% overload capacity for up to 1 minute

    175% overload capacity for up to 2 seconds

  • 8/9/2019 AC Ddives Baldor CA769

    26/11622

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    VS1MXS 500-600V 10% 3-Phase Input

    Catalog Number Frame Disconnect* Hp kW Output CurrentMatched Perf.

    Motor CodeList Price Mult. Sym.

    VS1MXS51-2T B No 1 0.75 1.7 A5 1,047 EA

    VSTMXS51-2TD B Yes 1 0.75 1.7 A5 1,152 EA

    VSTMXS52-2T B No 2 1.5 3.1 B5 1,266 EA

    VSTMXS52-2TD B Yes 2 1.5 3.1 B5 1,393 EA VSTMXS53-2T B No 3 2.2 4.1 C5 1,463 EA

    VSTMXS53-2TD B Yes 3 2.2 4.1 C5 1,610 EA

    VSTMXS55-2T B No 5 4 6.1 D5 1,819 EA

    VSTMXS55-2TD B Yes 5 4 6.1 D5 2,000 EA

    VSTMXS57-2T B No 7.5 5.5 9 E5 2,348 EA

    VSTMXS57-2TD B Yes 7.5 5.5 9 E5 2,582 EA

    Dimensions

    FrameHeight

    Inches (mm)

    Width

    Inches (mm)

    Depth

    Inches (mm)

    B 12.2 (310) 6.46 (164) 7.09 (180)

    Stock Model Numbers

    * Disconnect models include a speed potentiometer and F-O-R switch.

  • 8/9/2019 AC Ddives Baldor CA769

    27/11623

    VS1ST and VS1MX Accessories

    Remote Keypad for the VS1ST & VS1MX

    Catalog Number Description List Price Mult. Sym.

    VS1ST-RKEY3 VS1ST & VS1MX Remote Keypad with 3m cable 110 EA

    The VS1ST-RKEY3 Remote Keypad can be panel mounted for remote control or display of drive parameters. The kit comes standard with a 9 foot (3meter) cable and is suitable for IP54 mounting. This keypad can be used with either the VS1ST or the VS1MX. Depending on the requirement of theapplication, VS1ST-RKEY3 can be used point to point or with multiple drives.

    One Keypad with one drive One Keypad with multiple drives

    RS485 MODBUS RTU

    Cable Kits for the VS1ST & VS1MX

    Catalog Number Description List Price Mult. Sym.

    VS1ST-J45SP RJ45 Cable Splitter 23 EA

    VS1ST-CBL0P5 1.5 ft. (0.5m) RJ45 Cable 12 EA

    VS1ST-CBL1 3 ft. (1m) RJ45 Cable 12 EA

    VS1ST-CBL3 9 ft. (3m) RJ45 Cable 12 EA

    To support a basic serial network, option cable assemblies and splitters are available.

    RJ45 Copycat Loader for VS1ST and VS1MX

    Catalog Number Description List Price Mult. Sym.

    VS1ST-CCL VS1ST & VS1MX RJ45 Copycat Loader 28 EA

    This device allows uploading of drive parameters. Simply insert the device into the RJ45 port on the front ofthe VS1ST or VS1MX, press the upload button and you are done. Parameters are stored in memory and can bedownloaded later or used to duplicate drive setup across a number of drives.

    The data cable splitter is a RJ45 1 to 2 way connection block that is suitable formultiple drives connected to a communication network.

    Cables are available in three different lengths and come in blue.

    Real Time Operation: Once the communication has been setup between the drive and VS1ST-RKEY3, the user can control the VS1ST-RKEY3 by usingthe control buttons on the front panel of the Remote Keypad.

    Stock Model Numbers

    Stock Model Numbers

    Stock Model Numbers

  • 8/9/2019 AC Ddives Baldor CA769

    28/11624

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    VS1ST and VS1MX Accessories

    VS1ST Dynamic Braking Resistors

    Catalog Number Ohms Wattage Frame List Price Mult. Sym.

    VS1ST-R100W200 100 200 B & C 198 EA

    VS1ST Frame B and C drives include built-in braking transistors to aid in applications requiring the abilityto stop rapidly. The resistor kits are designed for the VS1ST and mount internal to the drive. The drivesoftware protects the brake kit from overload, there is no need for overload relays and an internal fusibleelement ensures fail safe operation.

    VS1ST & VS1MX Minimum Brake Resistor Values

    Frame HpMinimum Resistor Value

    (ohms)

    110-115V 2 47 Ohms

    200-240V 2 to 5 47 Ohms

    380-480V

    2 & 3 47 Ohms

    5 33 Ohms

    7.5 & 10 22 Ohms

    VS1ST & VS1MX Brake Voltage Levels

    Drive Voltage Brake Turn Off Level Brake Turn On Level

    200-240V 378 Vdc 390 Vdc

    380-480V 756 Vdc 780 Vdc

    VS1MX Dynamic Braking Resistors

    Drawing and Dimensions

    Catalog Number Ohms Wattage Frame List Price Mult. Sym.

    VS1MX R50W200 50 200 B & C 350 EA

    VS1MX Frame B and C drives include built-in braking transistors to aid in applications requiringthe ability to stop rapidly. The resistor kits are designed for the VS1MX and mount external tothe drive. The drive software protects the brake kit from overload, there is no need for overloadrelays and an internal fusible element ensures fail safe operation.

    Note: This kit will not function with the NEMA 4X (IP66) version of the VS1MX as no knock-out hole can be provided.Rated continuous power is 200W with a peak power level of 12kW for 0.125 seconds.Values for minimum brake resistance and brake voltage levels apply for both the VS1ST and VS1MX.

    Stock Model Numbers

    Stock Model Numbers

    Part Number L1 Inches (mm) L1 Inches (mm) L3 Inches (mm) L4 Inches (mm)

    VS1MX-R50W200 9.84 (250) 9.25 (235) 8.66 (220) 9.84 (250)

    Part Number B1 Inches (mm) H1 Inches (mm) D Inches (mm)

    VS1MX-R50W200 1.57 (40) 0.826 (21) 0.216 (5.5)

  • 8/9/2019 AC Ddives Baldor CA769

    29/11625

    Technical Specifications

    Size 4.72 x 2.95 x 1.06 (L x W x H)

    Power Supply

    24V 10% Consumption:Max 280 mA on 24VTypically 100 mA

    Temperature

    Operating +0C to 55C

    Non-Operating -5C to 85C

    Mounting DIN-Rail

    Protection Class IP20

    EMC Certification CE marked, UL & cUL Conformance

    Conformance Tested and verified for fieldbus conformance

    VS1ST & VS1MX Field Bus Gateways

    Catalog Number Description List Price Mult. Sym.

    VS1ST-PBUS Profibus Gateway Head 953 EA

    VS1ST-DNET DeviceNet Gateway Head 953 EA

    VS1ST-ENET Ethernet Gateway Head 902 EA

    The Field Bus Gateways incorporate the Anybus Communicator and can connect a VS1ST or VS1MX to industrial networks. The communicatorperforms an intelligent conversion between the drives serial protocol and the chosen industrial network.

    VS1ST and VS1MX Accessories

    Each gateway module is pre-programmed for the default number of drives. The gateway can be configured to match the number of drives connected(up to the maximum). The configuration files are available upon request from Baldor Electric. There are 2 cables supplied with the Gateway, one is for

    connecting to an Optidrive Plus & VTC drive network (RJ11), the second is for connecting to a VS1ST or VS1MX network (RJ45).

    RS485 MODBUS RTU

    Stock Model Numbers

    VS1MX IP55 Padlock

    Catalog Number Description List Price Mult. Sym.

    VS1MX-ILOCK VS1MX IP55 Padlock 36 EA

    VS1MX NEMA 12 (IP55) drives are available with an input disconnect that has provisions for lockout. The padlock kit is designed for use with this driveand fits the provided locking mechanism.

    Note:This kit will not function with the NEMA 4X (IP66) version of the VS1MX as no lockout hole can be provided.

    Stock Model Numbers

  • 8/9/2019 AC Ddives Baldor CA769

    30/11626

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Relay & Control Board Option Cards

    Catalog Number Description List Price Mult. Sym.

    VS1ST-2ROUT Provides one additional relay output for the drive 153 EA

    VS1ST-HVAC Provides two relays for drive running & drive tripped 153 EA

    VS1ST-LOGHV-11 115 VAC control logic input card 131 EA

    VS1ST-LOGHV-23 230 VAC control logic input card 131 EA

    To provide additional capabilities for the VS1ST and VS1MX, add on option cards are available. These include both I/O expansion and 115 or 230VACcontrol logic interface boards.

    VS1ST and VS1MX Accessories

    HVAC & 115/230 VAC Control Board 2nd Relay Output Module

    Size 56 x 33 x 14mm (L x W x H)

    Max relay switching voltage: 250V AC / 220V DC

    Max relay switching current: 1 A

    Temperature: Operating 10C to +50C

    Protection Class: IP20

    Conformity: IP00, UL94V-0

    Technical Specifications

    HVAC Relay Option Module

    The HVAC Relay Option Module can be used in applications where two indicators are required showing drive running and drive tripped. The firstrelay output (fitted within the drive) is programmed using P-22. When programmed as a fault relay the second relay output (that indicates a runcondition in the drive) is enabled. Relay 2 is closed when the drive is running.

    Relay 2 (J3) closed on enable Relay 1 (J1) closed when drive tripped

    (Green Light - Drive running) (Red Light)

    2nd Relay Option Module

    The Second Relay Output Module can be used in applications where the analog/digital output from the drive is converted to a relay output. Typicalapplications are where two relay outputs are required. The functions of the relays are programmable in the drive and can be programmed as driveenabled, drive healthy, drive at set speed, drive at zero speed, drive at max speed or motor in overload.

    115 & 230 VAC Control Interface Module

    This Option Module is designed for use with the VS1ST and VS1MX range of drives, to allow the digital inputs to be controlled directly from a 110Volt or 230 Volt control supply without the need for interfacing relays. There are two versions of the module, a 110 Volt version for voltages rangingfrom 100 120 VAC, and a 230 volt version for voltages ranging from 200 240VAC.

    The existing analog input on the VS1ST can still be used, by connecting the analog signal input on terminal 6, or alternatively a fourth 110 / 230VACdigital input can be connected via the removable plug.

    Stock Model Numbers

  • 8/9/2019 AC Ddives Baldor CA769

    31/11627

    VS1STS and VS1MXS Accessories

    Remote Keypad for the VS1STS & VS1MXS

    Catalog Number Description List Price Mult. Sym.

    VS1STS-RKEY3 VS1STS Remote Keypad with 3m cable 93 EA

    The VS1STS-RKEY3 Remote Keypad can be panel mounted for remote control or display of drive parameters. The kit comes standard with a 9 foot (3meter) cable and is suitable for IP54 mounting. This keypad can be used with either the VS1STS or the VS1MXS. Depending on the requirement of theapplication, VS1STS-RKEY3 can be used point to point or with multiple drives.

    One Keypad with one drive One Keypad with multiple drives

    Cable Kits for the VS1STS & VS1MXS

    Catalog Number Description List Price Mult. Sym.

    VS1STS-J11SP RJ45 Cable Splitter 24 EA

    VS1STS-CBL0P3 1 ft. (0.3m) RJ11 Cable 6 EA

    VS1STS-CBL1 3 ft. (1m) RJ11 Cable 8 EA

    VS1STS-CBL3 9 ft. (3m) RJ11 Cable 12 EA

    To support a basic serial network, option cable assemblies and splitters are available.

    The data cable splitter is a RJ45 1 to 2 way connection block that is suitable formultiple drives connected to a communication network.

    Cables are available in three different lengths and come in blue.

    Real Time Operation: Once the communication has been setup between the drive and VS1STS-RKEY3, the user can control the VS1STS-RKEY3 byusing the control buttons on the front panel of the Remote Keypad.

    Stock Model Numbers

    Stock Model Numbers

    This kit allows communication between a USB port on a computer and the VS1 Drive RS485 control terminals.

    Description Catalog Number List Price Mult. Sym.

    VS1 USB to RS485 Converter Kit VS1-COMMUSB 529 EA

    Stock Model Numbers

  • 8/9/2019 AC Ddives Baldor CA769

    32/11628

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    ACB330AC Micro Drive

    1/2 thru 3 Hp 230 Vac 1 Phase - 50/60 Hz

    1/2 thru 15 Hp 230 Vac 3 Phase - 50/60 Hz

    1/2 thru 30 Hp 460 Vac 3 Phase - 50/60 Hz

    Applications:Variable torque, constant torque or constant horsepower applications. Newinstallations, replacements and original equipment manufactures (OEM).

    Features: Volts per Hertz or Sensorless Vector Control with peak overload capacity of 150%and PID capability. Flexible mounting options with IP20 enclosure as standard and UL Type 1option kit. Removable keypad with operator interface and local speed control. Programming byGroups makes it easy to navigate and find parameters. A quick start assistant enables users toprogram and start using the drive in minutes without need for a User Manual. Built-in brakingtransistor allows connection to remote braking resistor for enhanced performance needs.

    Performance Features Control Modes V/Hz or Sensorless VectorMotor Control Induction or Permanent MagnetOperator Interface Module Integral Drive MountedKeypad Display LCD Graphical DisplayProgrammable Preset Speeds SevenAnalog Outputs One (0/4 - 20 maDC)Auto Restart Yes -- Up to 5 attemptsFrequency Avoidance Three BandsFault History Last Three FaultsDigital Inputs Five Configurable InputsDigital Inputs Type Pull-up or Pull-down

    Drive Specifications Analog Inputs: Two Total 0-10VDC, -10 to 10VDC or 0/4 - 20maDCDigi tal Outputs: Two Total One Transistor Output

    One Form C RelayAnalog Outputs 0/4 - 20maDCOverload Capacity Drive Output 150% for 1 min., 180% for 2 sec. at startSafe Torque Off STO SIL3Speed Control Accuracy Stat ic: 20% of motor nominal s lipInput Voltage Ranges: 200 - 240VAC; 380 - 480VAC

    Input Voltage Tolerance 10% / -10%Rated Input Frequency 50-60Hz (5%)Carrier Frequency: 4-16 kHz (4 kHz default)Operating Temperature: 10 to 40C; 10 to 50C w/ 10% derateSnubber (Dynamic Braking): Built-in TransistorFlux Braking: StandardDC Injection Braking: StandardFlux Optimization: Can improve efficiency up to 10% on light loadsVolts/Hz Linear V/Hz

    Quadratic V/HzCustom 4-Point V/Hz Curve

    Sensorless Vector: Full Sensorless Vector Control with Autotune Function and Motor Model CalculationFrequency Control Range: 0-600 HzAccel/Decel: Two independently adjustable sets of rampsTime Range: 0.0 to 1800 Seconds

    S Curve Accel . & Decel. Yes, with adjustable rounding t imeKeypad Speed Control YesSink/Source Inputs Selectable, 24 VDC LogicElectronic Overload Trip Electronic Motor Overload Inverse Time calculationCommunications Built-in MODBUS-RTU (RS-232) CommunicationsPID Control Built-in

    Protective Features Under Voltage Level Depends on Voltage Class (240, 480)Ground Fault Protection Ground Fault protection active during runOutput Short Circuit Phase-to-Phase on Drive OutputOver Temperature Heatsink MonitorMotor Overtemp Excessive estimated Motor TemperatureDC Bus Overvoltage DC Bus Level Trip

    IGBT Overtemp Drive Output IGBT Temp is too highOver Current Over-current/short-Circuit protection

  • 8/9/2019 AC Ddives Baldor CA769

    33/11629

    Protective Features

    (cont.)

    Output Phase Trips on open Output PhaseLoss of Reference Trips on Loss of Speed Command SignalComm. Error Detects a communication error (fault)Loss of Keypad Drive will trip if under keypad control and keypad communication is lostMotor Model Calc Fail Drive will trip if Motor Model cannot be determined - Sensorless Vector Control

    Agency Certifications UL, cUL, CE, C-tick, RoHS, TUV, NORD,Service Conditions Altitude: 1,000 m (3,300 ft.). D erate by 1% every 100 m (328 ft.) up to 2,000m (6,600 ft.)

    Ambient Temperature: -10C (14F) to 40C (104F) - up to 50C with 10% derate

    Relative Humidity: 0% to 95%, non-condensingIntermittent Overload: 150% overload capacity for up to 1 minute

    180% overload capacity for up to 2 seconds

    ACB330 - 230V, 50/60Hz, 1-Phase

    Catalog Number

    Heavy Duty

    List Price Mult. Sym.Frame Hp Cont. Amps

    Matched Perf.

    Motor Code

    ACB330-01U-02A4-2 R0 0.5 A2 A2 493 EF

    ACB330-01U-04A7-2 R1 1.0 B2 B2 539 EF

    ACB330-01U-07A5-2 R2 2.0 C2 C2 629 EF

    ACB330-01U-09A8-2 R2 3.0 D2 D2 726 EF

    ACB330 - 230V, 50/60Hz, 3-Phase

    Catalog Number

    Heavy Duty

    List Price Mult. Sym.Frame Hp Cont. Amps

    Matched Perf.

    Motor Code

    ACB330-03U-02A4-2 R0 0.5 A2 A2 493 EF

    ACB330-03U-04A7-2 R1 1 B2 B2 539 EF

    ACB330-03U-07A5-2 R1 2 C2 C2 629 EF

    ACB330-03U-09A8-2 R2 3 D2 D2 726 EF

    ACB330-03U-17A6-2 R2 5 E2 E2 862 EF

    ACB330-03U-24A4-2 R3 7.5 F2 F2 1 076 EF

    ACB330-03U-31A0-2 R4 10 G2 G2 1 370 EF

    ACB330-03U-46A2-2 R4 15 H2 H2 1 760 EF

    ACB330 - 460V, 50/60Hz, 3-Phase

    Catalog Number

    Heavy Duty

    List Price Mult. Sym.Frame Hp Cont. Amps

    Matched Perf.

    Motor Code

    ACB330-03U-01A2-4 R0 0.5 558 EF

    ACB330-03U-02A4-4 R1 1 A4 A4 640 EF

    ACB330-03U-04A1-4 R1 2 B4 B4 714 EF

    ACB330-03U-05A6-4 R1 3 C4 C4 832 EF

    ACB330-03U-08A8-4 R1 5 D4 D4 958 EF

    ACB330-03U-12A5-4 R3 7.5 E4 E4 1 142 EF

    ACB330-03U-15A6-4 R3 10 F4 F4 1 372 EF

    ACB330-03U-23A1-4 R3 15 G4 G4 1 710 EF

    ACB330-03U-31A0-4 R4 20 H4 H4 2 052 EF

    ACB330-03U-38A0-4 R4 25 I4 I4 2 411 EF

    ACB330-03U-44A0-4 R4 30 J4 J4 2 895 EF

  • 8/9/2019 AC Ddives Baldor CA769

    34/11630

    B

    ld

    ACB

    D

    i

    /L

    b

    ACMi

    ACI

    ACV

    C

    li

    T

    A

    l

    AC

    C

    B

    ld

    S

    f

    A

    li

    i

    L

    D

    i

    Gl

    Id

    B

    ld

    D

    i

    Catalog Number List Price Mult. Sym.

    MPOT-01 Potentiometer with two switches: Start/Stop and Forward/ Reverse. Polarity is selected with DIP switches. No external powersource is needed for the potentiometer.

    30 EF

    OPMP-01 Control Panel Mounting Platform allows remote mounting of the keypad on a large enclosure or remote panel. The kit maintainsUL Type 12 integrity of the mounting location. Adapters, 3 m (10ft) cable and mounting hardware are included in this kit. Withthis mounting arrangement, the keypad is removable from the panel in a fashion identical to a drive-mounted keypad.

    138 EF

    ACS/H-CP-EXT Control Panel Mounting Kit for ACB530 drives allows remote mounting of the ACB530 keypad on the door of an enclosure. Thekit includes a 10 ft (3 m) CAT 5 patch cable, gasket for NEMA 12, mounting hardware and drilling template.

    55 EF

    ACS/H-CP-EXT-IP66 Allows remote mounting of the ACB-CP-BA Operator Panels on a larger NEMA 4X (IP66) enclosure or remote panel. Thekit maintains NEMA 4X integrity of the mounting location. All necessary hardware and a mounting template are provided inaddition to a 3 m panel cable. When mounted, the operator is not removable from the front of the enclosure. The operator panelmust be purchased separately.

    63 EF

    OCAT-01 7 foot CAT 5 patch cable allows remote operation o f the standard panel or connection of the drive to a Personal Computerusing the RJ45/DB9 Adapter which must be purchased separately.

    40 EF

    MPOW-01 The optional auxiliary power module provides auxiliary voltage to the control panel, fieldbus, and I/O 125 EFFDNA-01 DeviceNet network uses a linear bus topology. Terminating resistors are required on each end of the trunk line. Drop lines

    as long as 6 meters (20 feet) each are permitted, allowing one or more nodes to be attached. DeviceNet allows branchingstructures only on drop lines.

    260 EF

    FENA-01 The FENA-01 module supports Modbus-TCP, EtherNet/IP and ProfiNet IO. The Modbus-TCP protocol is simply the Modbusprotocol used on top of Ethernet-TCP/IP. Modbus-TCP is an open Industrial Ethernet network which has been specified by theModbus-IDA User Organization. EtherNet/ IP is based on the Common Industrial Protocol (CIP), which is also the framework

    for both the ControlNet and DeviceNet network protocols. ProfiNet IO is an open standard for Industrial Ethernet intended forconfiguration, supervision & control of automation equipment. The FENA-01 supports 10/100 Mbps transfer rate with networkconnections made with CAT 5 wiring and RJ-45 connectors. Both star and bus topology options are supported.

    400 EF

    FECA-01 The FECA-01 module supports EtherCAT network protocol. EtherCAT is a Real Time Ethernet technology which aimsto maximize the use of the full duplex Ethernet bandwidth. It overcomes the overhead normally associated with Ethernetby employing on the fly processing hardware. An EtherCAT bus consists of a master system and up to 65535 slavedevices, connected together with standard Ethernet cabling. The FECA-01 supports 10/100 Mbps transfer rate with networkconnections made with CAT 5 wiring and RJ-45 connectors. Designed for daisy chain configuration on an EtherCAT network.

    400 EF

    FPBA-01 PROFIBUS is an open serial communication standard that enables data exchange between all kinds of automation components.The physical transmission medium of the bus is a twisted pair cable (according to the RS-485 standard). The maximum lengthof the bus cable is 100 to 1200 meters, depending on the selected transmission rate. Up to 31 stations can be connected tothe same PROFIBUS system without the use of repeaters.

    290 EF

    FMBA-01 Modbus is a serial, asynchronous protocol. The Modbus protocol does not specify the physical interface. Typical physicalinterfaces are RS-232 and RS-485. The FMBA-01 provides a galvanically isolated RS-485 interface. Modbus is designed forintegration with Modicon PLCs or other automation devices, and the services closely correspond to the PLC architecture. The

    FMBA-01 supports the RTU protocol only.

    142 EF

    MUL1-R1

    MUL1-R3

    MUL1-R4

    This option provides the necessar y hardware to modify the ACB330 drive from the standard fingersafe protected chassis toNEMA 1 protection capable of landing conduit. MUL1-R1 kit is used with frame sizes R0 through R2, MUL1-R3 is used withframe size R3, and MUL1-R4 is used with frame size R4.

    7575100

    EF

    ACB330 Option Kits

    FrameSize

    IP20 (cabinet) UL Open NEMA 1 / UL Type 1

    H1(in)

    H2(in)

    H3(in)

    W(in)

    D(in)

    Wt.(lb)

    H4(in)

    H5(in)

    W(in)

    D(in)

    Wt.(lb)

    R0 6.65 7.95 9.41 2.76 6.34 2.6 10.12 11.02 2.76 6.65 3.5

    R1 6.65 7.95 9.41 2.76 6.34 2.6 10.12 11.02 2.76 6.65 3.5

    R2 6.65 7.95 9.41 4.13 6.50 3.3 10.12 11.10 4.13 6.65 4.2

    R3 6.65 7.95 9.29 6.65 6.65 5.5 10.24 11.77 6.65 6.97 6.8

    R4 7.13 7.95 9.61 10.24 6.65 9.7 10.63 12.60 10.24 6.97 11.0

    1UN= 200 ... 240V