8
® EASA DEK FLOOR FORMER FITTING INSTRUCTIONS RECEVEUR EASA DEK - NOTICE D’INSTALLATION Floor former sizes in this range (mm) Les dimensions des receveurs de cette gamme (mm) 900 x 900 1050 x 1050 1150 x 750 1220 x 1220 1300 x 800 1400 x 900 1500 x 800 1700 x 750 ENGLISH FRANÇAIS

Access Tray Fitting Instructions for Solid Floors - Easa Group

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Access Tray Fitting Instructions for Solid Floors - Easa Group

®

Access Tray Fitting Instructions for Solid Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

3. Decide on direction of waste and breakout wall if required. For the waste it is necessary to break out 150mm diameter to a depth of 150mm. Repair any damage to damp proof course membrane. Install the waste piping (minimum fall 1 in 40). The waste should line up with the centre of the waste opening in the tray. Please read the separate waste instructions.

3. Décidez du sens de l’évacuation et faites une brèche dans le mur si nécessaire. Pour accueillir la bonde de vidage, il est nécessaire de faire une brèche dont le diamètre et la profondeur seront fonction de la bonde utilisée. Réparez tout dommage à la membrane d’étanchéité. Installez la tuyauterie d’évacuation (pente minimale de 1 pour 40). Celle-ci devra être reliée à la bonde de vidage située au niveau du perçage du receveur. Veuillez-vous référer aux notices livrées séparément avec la bonde de vidage.

4. Add support under the tray by laying a weak concrete mix in excavated area.

4. Ajoutez un support sous le bac en disposant un faible mélange de béton dans la zone décaissée.

Decide whether the tray is going to be installed recessed into the floor (barrier free) or mounted on top of the floor (easy access). If mounting on top of the floor, do not excavate the floor.

Décidez si le receveur sera encastré dans le sol (accès sans obstacle) ou monté en surface (accès facile). Si le receveur est monté en surface, il n’est alors pas nécessaire de toucher au sol existant.

1. Place tray in position and mark out the size on the floor.

1. Positionnez le receveur et délimitez la dimension sur le sol.

2. Break out screed or concrete to a minimum depth of 40mm. Check that the tray fits into the opening.

2. Décaissez la chape ou le béton sur une profondeur minimale de 40mm. Vérifiez que le receveur s’insère dans l’ouverture

®

Access Tray Fitting Instructions for Solid Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Evolution Grab Rails Fitting Instructions

1. Measure from the floor up to the desired height of the top anchor. Mark with pencil for centre of Anchor plate.

2. For stud walls, place the anchor plate on the stud location and mark the screw holes with a pencil.

Items that may be required:

• Tape measure • Pencil• Variable speed drill • Drill bit set • Screwdriver• Stud finder • Pipe and voltage detector • Masking tape

If the bathroom is being fitted for a particular disabled person, bear in mind their height to consider where the grab rails may be positioned.

Please ensure that the correct type of screws are used for the type of wall and loading required. Do not enlarge any of the grab rail mounting holes nor over-tighten the screws.

Use a pipe and voltage detector to make sure that there are no wires and/or pipes behind the walls where you are seeking to position the grab rails.

For stud walls, locate the wall studs with a stud finder. Place a pencil mark on the stud location. Locate two studs on the wall of the shower based on the length of the handrail. Mark the stud locations with a pencil.

Mark with a pencil the location where you will install the grab rail.

Double check your measurements so that you are completely sure of them before beginning any work.

Easa Export: Tel : +32 (0) 491 330 717 | Fax : +44 (0) 28 92 61 23 26 | Email : [email protected] | Website : www.easagroup.comEasa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.ukEasa Export - Tél: +32 (0) 491 330717 • Télécopie: +44 (0) 28 9261 2326 • Email: [email protected] • Site web: www.easagroup.com

Access Tray Fitting Instructions for Solid Floors Receveur Access - Notice d’installation pour sol dur Depending on the size, the tray may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging.

Selon la taille, il se peut que le receveur soit relativement lourd, veuillez être prudent lors de sa manipulation. Protégez le receveur de douche de tout dommage à l’aide des emballages cartonnés.

ACCESS TRAYS MUST NOT BE CUT

LE RECEVEUR ACCESS NE DOIT PAS ETRE COUPÉ

®

Receveur Access - Notice d’installation pour sol bois

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

English / Français

EASA DEK FLOOR FORMERFITTING INSTRUCTIONS

RECEVEUR EASA DEK - NOTICE D’INSTALLATION

Floor former sizes in this range (mm)Les dimensions des receveurs de cette gamme (mm)

900 x 900 1050 x 1050 1150 x 750 1220 x 1220 1300 x 800 1400 x 900 1500 x 800 1700 x 750

ENGLISHFRANÇAIS

Page 2: Access Tray Fitting Instructions for Solid Floors - Easa Group

® Depending on the size, the Floor Former may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging. Please note that the floor former must not be fitted without a floor covering applied on top, e.g. sheet vinyl flooring, tiles, etc.

All of the Easa Dek range of Floor Formers can be cut to size using a conventional hacksaw or stone blade grinder. However it is important that any cut edges are placed to the wall. It is not possible to place any cut edges to the outside edges where the floor former meets the floor.

Floor Former can be cut to size using a conventional hacksaw or stone blade grinder. Cut edges MUST be placed against a wall.

EASA DEK | Fitting Instructions for Wooden Floors

1. Place Floor Former in position and mark out the size on the floor.

2. Cut out floor sheeting or floor boards and check that the floor former fits into the opening.

3. Floor Former should be rotated so that the waste does not interfere with joists.

4. Decide on direction of waste outlet pipe and breakout wall as required – install the waste piping (minimum fall 1 in 40), it should line up with the centre of the waste opening in the Floor Former. Please read the separate waste instructions.

5. Standard Method - At each end of the Floor Former add purlins between the joists, then add additional purlins at 400mm intervals.

CROSS SECTION VIEW

6. Joists and purlins must be level on all sides.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

CROSS SECTION VIEW

® Depending on the size, the Floor Former may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging. Please note that the floor former must not be fitted without a floor covering applied on top, e.g. sheet vinyl flooring, tiles, etc.

All of the Easa Dek range of Floor Formers can be cut to size using a conventional hacksaw or stone blade grinder. However it is important that any cut edges are placed to the wall. It is not possible to place any cut edges to the outside edges where the floor former meets the floor.

Easa Dek Fitting Instructions for Solid Floors

1. Place Floor Former in position and mark out the size on the floor.

2. Break out screed or concrete to a minimum depth of 25mm. Check that the Floor Former fits into the opening.

3. Decide on direction of waste and breakout wall if required. For the waste it is necessary to break out 150mm diameter to a depth of 150mm. Repair any damage to damp proof course membrane. Install the waste piping (minimum fall 1 in 40). It should line up with the centre of the waste opening in the Floor Former. Please read the separate waste instructions.

4. Add support under the Floor Former by laying aweak concrete mix in excavated area.

Floor Former can be cut to size using a conventional hacksaw or stone blade grinder. Cut edges MUST be placed against a wall.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

® Depending on the size, the Floor Former may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging. Please note that the floor former must not be fitted without a floor covering applied on top, e.g. sheet vinyl flooring, tiles, etc.

All of the Easa Dek range of Floor Formers can be cut to size using a conventional hacksaw or stone blade grinder. However it is important that any cut edges are placed to the wall. It is not possible to place any cut edges to the outside edges where the floor former meets the floor.

Easa Dek Fitting Instructions for Solid Floors

1. Place Floor Former in position and mark out the size on the floor.

2. Break out screed or concrete to a minimum depth of 25mm. Check that the Floor Former fits into the opening.

3. Decide on direction of waste and breakout wall if required. For the waste it is necessary to break out 150mm diameter to a depth of 150mm. Repair any damage to damp proof course membrane. Install the waste piping (minimum fall 1 in 40). It should line up with the centre of the waste opening in the Floor Former. Please read the separate waste instructions.

4. Add support under the Floor Former by laying aweak concrete mix in excavated area.

Floor Former can be cut to size using a conventional hacksaw or stone blade grinder. Cut edges MUST be placed against a wall.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

3. Decide on direction of waste and breakout wall if required. For the waste it is necessary to break out 150mm diameter to a depth of 150mm. Repair any damage to damp proof course membrane. Install the waste piping (minimum fall 1 in 40). It should line up with the centre of the waste opening in the Floor Former.Please read the separate waste instructions.

3. Décider de la direction de l’évacuation de l’eau et percer le mur si nécessaire. Pour accueillir la bonde de vidage, il est nécessaire de prévoir un décaissement supplémentaire dont le diamètre la profondeur seront fonction de la bonde utilisés. Réparer tout dommage à la membrane d’étanchéité. Installer la tuyauterie d’évacuation (pente minimum de 1/40). Celle-ci devra être reliée à la bonde de vidage située au niveau du perçage du receveur. Nous vous invitons à consulter les notices d’installation livrées avec la bonde de vidage.

Floor Former can be cut to size using a conventional hacksaw or stone blade grinder.

Cut edges MUST be placed against a wall.

Le receveur de douche peut être coupé à dimension souhaitée à l’aide d’une scie à métaux classique ou d’une meuleuse. Cependant il est important que tous les bords coupés soient placés au contact du mur.

2. Break out screed or concrete to a minimum depth of 25mm. Check that the Floor Former fits into the opening.

2. Décaisser la dalle ou la chape de béton d’une profondeur minimale de 25mm. Vérifier que le receveur de douche s’inscrit dans l’ouverture.

4. Add support under the Floor Former by laying a weak concrete mix in excavated area.

4. Ajoutez un support sous le bac en disposant un faible mélange de béton dans la zone décaissée.

®

Access Tray Fitting Instructions for Solid Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Evolution Grab Rails Fitting Instructions

1. Measure from the floor up to the desired height of the top anchor. Mark with pencil for centre of Anchor plate.

2. For stud walls, place the anchor plate on the stud location and mark the screw holes with a pencil.

Items that may be required:

• Tape measure • Pencil• Variable speed drill • Drill bit set • Screwdriver• Stud finder • Pipe and voltage detector • Masking tape

If the bathroom is being fitted for a particular disabled person, bear in mind their height to consider where the grab rails may be positioned.

Please ensure that the correct type of screws are used for the type of wall and loading required. Do not enlarge any of the grab rail mounting holes nor over-tighten the screws.

Use a pipe and voltage detector to make sure that there are no wires and/or pipes behind the walls where you are seeking to position the grab rails.

For stud walls, locate the wall studs with a stud finder. Place a pencil mark on the stud location. Locate two studs on the wall of the shower based on the length of the handrail. Mark the stud locations with a pencil.

Mark with a pencil the location where you will install the grab rail.

Double check your measurements so that you are completely sure of them before beginning any work.

Easa Export: Tel : +32 (0) 491 330 717 | Fax : +44 (0) 28 92 61 23 26 | Email : [email protected] | Website : www.easagroup.comEasa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.ukEasa Export - Tél: +32 (0) 491 330717 • Télécopie: +44 (0) 28 9261 2326 • Email: [email protected] • Site web: www.easagroup.com

Easa Dek Fitting Instructions for Solid FloorsEASA DEK Notice d’installation sur sol béton Depending on the size, the Floor Former may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging. Please note that the floor former must not be fitted without a floor covering applied on top, e.g. sheet vinyl flooring, tiles, etc.

Attention, selon la taille, le receveur peut être lourd, soyez prudent lors de la manutention. Protéger le receveur contre les dommages en utilisant les emballages en carton. En aucun cas, le receveur EASA DEK ne pourra être utilisé sans avoir été recouvert d’un revêtement de douche vinyle étanche ou de carrelage.

English / Français

All of the Easa Dek range of Floor Formers can be cut to size using a conventional hacksaw or stone blade grinder. However it is important that any cut edges are placed to the wall. It is not possible to place any cut edges to the outside edges where the floor former meets the floor.

Toute la gamme de receveur pour sol de douche à l’Italienne Easa Dek peut être coupé à dimension en utilisant une scie à métaux classique ou une meuleuse. Cependant il est important que tous les bords coupés soient placés au contact du mur. Il n’est pas possible de placer les bords coupés vers l’extérieur à l’endroit ou le receveur sera en contact avec le sol.

1. Place Floor Former in position and mark out the size on the floor.

1. Positionner le receveur de douche et marquer la taille du receveur sur le sol

® Depending on the size, the Floor Former may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging. Please note that the floor former must not be fitted without a floor covering applied on top, e.g. sheet vinyl flooring, tiles, etc.

All of the Easa Dek range of Floor Formers can be cut to size using a conventional hacksaw or stone blade grinder. However it is important that any cut edges are placed to the wall. It is not possible to place any cut edges to the outside edges where the floor former meets the floor.

Easa Dek Fitting Instructions for Solid Floors

1. Place Floor Former in position and mark out the size on the floor.

2. Break out screed or concrete to a minimum depth of 25mm. Check that the Floor Former fits into the opening.

3. Decide on direction of waste and breakout wall if required. For the waste it is necessary to break out 150mm diameter to a depth of 150mm. Repair any damage to damp proof course membrane. Install the waste piping (minimum fall 1 in 40). It should line up with the centre of the waste opening in the Floor Former. Please read the separate waste instructions.

4. Add support under the Floor Former by laying aweak concrete mix in excavated area.

Floor Former can be cut to size using a conventional hacksaw or stone blade grinder. Cut edges MUST be placed against a wall.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

Page 3: Access Tray Fitting Instructions for Solid Floors - Easa Group

®Easa Dek Fitting Instructions for Solid Floors

8. The seam between floor and Floor Former must be completely level. Fill any gaps with polyester filler paste. For tile floor installations you will need to apply the Easa tanking system as per kit instructions.

7. When the waste is seated in position, use a 3.5mm drill bit to bore through the 4 location holes of the waste flange into the floor former. Be careful not to go too deep as the waste pipe is underneath. Fit self tapping screws provided to secure the waste into place. Do not over-tighten the screws.

6. Ensure Floor Former is level on all sides.

Please Note: Apply sheet flooring or tiles as required using appropriate adhesive. The correct waste (or adaptor) must be used depending on flooring type – see separate waste instructions for fitting waste to appropriate flooring type.

5. Place the Floor Former gently into position – do not drop as this could cause damage.

To ensure a waterproof seal a tiling upstand may be added to the edges of the floor former that will be placed against the walls. Optional rigid aluminium or flexible EPDM upstands are available.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Easa Dek Fitting Instructions for Solid Floors

8. The seam between floor and Floor Former must be completely level. Fill any gaps with polyester filler paste. For tile floor installations you will need to apply the Easa tanking system as per kit instructions.

7. When the waste is seated in position, use a 3.5mm drill bit to bore through the 4 location holes of the waste flange into the floor former. Be careful not to go too deep as the waste pipe is underneath. Fit self tapping screws provided to secure the waste into place. Do not over-tighten the screws.

6. Ensure Floor Former is level on all sides.

Please Note: Apply sheet flooring or tiles as required using appropriate adhesive. The correct waste (or adaptor) must be used depending on flooring type – see separate waste instructions for fitting waste to appropriate flooring type.

5. Place the Floor Former gently into position – do not drop as this could cause damage.

To ensure a waterproof seal a tiling upstand may be added to the edges of the floor former that will be placed against the walls. Optional rigid aluminium or flexible EPDM upstands are available.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Easa Dek Fitting Instructions for Solid Floors

8. The seam between floor and Floor Former must be completely level. Fill any gaps with polyester filler paste. For tile floor installations you will need to apply the Easa tanking system as per kit instructions.

7. When the waste is seated in position, use a 3.5mm drill bit to bore through the 4 location holes of the waste flange into the floor former. Be careful not to go too deep as the waste pipe is underneath. Fit self tapping screws provided to secure the waste into place. Do not over-tighten the screws.

6. Ensure Floor Former is level on all sides.

Please Note: Apply sheet flooring or tiles as required using appropriate adhesive. The correct waste (or adaptor) must be used depending on flooring type – see separate waste instructions for fitting waste to appropriate flooring type.

5. Place the Floor Former gently into position – do not drop as this could cause damage.

To ensure a waterproof seal a tiling upstand may be added to the edges of the floor former that will be placed against the walls. Optional rigid aluminium or flexible EPDM upstands are available.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

8. The seam between floor and Floor Former must be completely level. Fill any gaps with polyester filler paste. For tile floor installations you will need to apply the Easa tanking system as per kit instructions.

8. Le joint entre le plancher et le receveur de douche doit être parfaitement de niveau. Combler les lacunes éventuelles avec de la pâte polyester de remplissage. Si nécessaire, appliquer un kit d’étanchéité en suivant les instructions du fabricant.

7. When the waste is seated in position, use a 3.5mm drill bit to bore through the 4 location holes of the waste flange into the floor former. Be careful not to go too deep as the waste pipe is underneath. Fit self tapping screws provided to secure the waste into place. Do not over-tighten the screws.

7. Lorsque la bonde est en position, utiliser un foret de 3,5 mm et percer les trous de positionnement de la bonde d’évacuation dans le receveur. Veillez à ne pas percer trop profond car le tuyau d’évacuation passe sous le receveur. Serrer les vis auto taraudeuses fournies pour fixer la bonde en place. Assurez-vous de ne pas serrer les vis trop fort.

®

Access Tray Fitting Instructions for Solid Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Evolution Grab Rails Fitting Instructions

1. Measure from the floor up to the desired height of the top anchor. Mark with pencil for centre of Anchor plate.

2. For stud walls, place the anchor plate on the stud location and mark the screw holes with a pencil.

Items that may be required:

• Tape measure • Pencil• Variable speed drill • Drill bit set • Screwdriver• Stud finder • Pipe and voltage detector • Masking tape

If the bathroom is being fitted for a particular disabled person, bear in mind their height to consider where the grab rails may be positioned.

Please ensure that the correct type of screws are used for the type of wall and loading required. Do not enlarge any of the grab rail mounting holes nor over-tighten the screws.

Use a pipe and voltage detector to make sure that there are no wires and/or pipes behind the walls where you are seeking to position the grab rails.

For stud walls, locate the wall studs with a stud finder. Place a pencil mark on the stud location. Locate two studs on the wall of the shower based on the length of the handrail. Mark the stud locations with a pencil.

Mark with a pencil the location where you will install the grab rail.

Double check your measurements so that you are completely sure of them before beginning any work.

Easa Export: Tel : +32 (0) 491 330 717 | Fax : +44 (0) 28 92 61 23 26 | Email : [email protected] | Website : www.easagroup.comEasa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.ukEasa Export - Tél: +32 (0) 491 330717 • Télécopie: +44 (0) 28 9261 2326 • Email: [email protected] • Site web: www.easagroup.com

Easa Dek Fitting Instructions for Solid FloorsEASA DEK Notice d’installation sur sol béton

English / Français

6. Ensure Floor Former is level on all sides.

6. Assurez-vous que le receveur est de niveau sur ces 4 cotés.

To ensure a waterproof seal a tiling upstand may be added to the edges of the floor former that will be placed against the walls. Optional rigid aluminium or flexible EPDM upstands are available.

Afin d’assurer une meilleure étanchéité de l’installation, le profilé carrelage Aluminium devra être disposé sur les bords du receveur placés contre les murs. Des profilés rigides ou flexibles supplémentaires sont disponibles dans nos usines si besoin.

Please Note: Apply sheet flooring or tiles as required using appropriate adhesive. The correct waste (or adaptor) must be used depending on flooring type – see separate waste instructions for fitting waste to appropriate flooring type.

Note : Recouvrir le receveur d’un sol souple vinyle étanche ou d’un carrelage en appliquant la colle appropriée. Un adaptateur pour sol carrelé ou sol souple doit être utilisé en fonction du revêtement de sol qui recouvre le receveur.

5. Place the Floor Former gently into position – do not drop as this could cause damage.

5. Placer le receveur de douche doucement dans son emplacement - ne pas le laisser tomber, car cela pourrait l’endommager.

Page 4: Access Tray Fitting Instructions for Solid Floors - Easa Group

® Depending on the size, the Floor Former may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging. Please note that the floor former must not be fitted without a floor covering applied on top, e.g. sheet vinyl flooring, tiles, etc.

All of the Easa Dek range of Floor Formers can be cut to size using a conventional hacksaw or stone blade grinder. However it is important that any cut edges are placed to the wall. It is not possible to place any cut edges to the outside edges where the floor former meets the floor.

Floor Former can be cut to size using a conventional hacksaw or stone blade grinder. Cut edges MUST be placed against a wall.

EASA DEK | Fitting Instructions for Wooden Floors

1. Place Floor Former in position and mark out the size on the floor.

2. Cut out floor sheeting or floor boards and check that the floor former fits into the opening.

3. Floor Former should be rotated so that the waste does not interfere with joists.

4. Decide on direction of waste outlet pipe and breakout wall as required – install the waste piping (minimum fall 1 in 40), it should line up with the centre of the waste opening in the Floor Former. Please read the separate waste instructions.

5. Standard Method - At each end of the Floor Former add purlins between the joists, then add additional purlins at 400mm intervals.

CROSS SECTION VIEW

6. Joists and purlins must be level on all sides.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

CROSS SECTION VIEW

®Evolution Grab Rails Fitting Instructions

1. Measure from the floor up to the desired height of the top anchor. Mark with pencil for centre of Anchor plate.

2. For stud walls, place the anchor plate on the stud location and mark the screw holes with a pencil.

Items that may be required:

• Tape measure • Pencil• Variable speed drill • Drill bit set • Screwdriver• Stud finder • Pipe and voltage detector • Masking tape

If the bathroom is being fitted for a particular disabled person, bear in mind their height to consider where the grab rails may be positioned.

Please ensure that the correct type of screws are used for the type of wall and loading required. Do not enlarge any of the grab rail mounting holes nor over-tighten the screws.

Use a pipe and voltage detector to make sure that there are no wires and/or pipes behind the walls where you are seeking to position the grab rails.

For stud walls, locate the wall studs with a stud finder. Place a pencil mark on the stud location. Locate two studs on the wall of the shower based on the length of the handrail. Mark the stud locations with a pencil.

Mark with a pencil the location where you will install the grab rail.

Double check your measurements so that you are completely sure of them before beginning any work.

Easa Export: Tel : +32 (0) 491 330 717 | Fax : +44 (0) 28 92 61 23 26 | Email : [email protected] | Website : www.easagroup.comEasa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.ukEasa Export - Tél: +32 (0) 491 330717 • Télécopie: +44 (0) 28 9261 2326 • Email: [email protected] • Site web: www.easagroup.com

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

10. Apply a high strength filled rubber resin gap filling adhesive between the tray and the floor. This will ensure that the tray is held securely in place. When fitting waste to tray add neutral silicone sealant above and below flat rubber seal. Place the tray gently into position – do not drop as this could cause damage. When bedding into position make sure the outlet pipe fits neatly into the waste.

10. Appliquez un adhésif haute-résistance à base de résine de caoutchouc. Cela assurera que le receveur soit maintenu en place de manière sécurisée. Lors de l’installation de la bonde sur le receveur, ajoutez un joint silicone neutre au-dessus et en dessous du joint plat en caoutchouc. Positionnez doucement le receveur – ne pas le laissez tomber, cela pouvant entraîner des dommages. Lorsque vous couchez le receveur, veillez à ce que la tuyauterie s’adapte parfaitement à la bonde.

12. For recessed trays it is necessary to add plywood sheets followed by vinyl or tiles to bring the floor level up to the same height as the tray.

12. Pour les receveurs encastrés, il est nécessaire d’ajouter des panneaux de contreplaqué recouvert d’un sol vinyle ou carrelage afin de mettre à niveau sol et receveur.

9. To ensure a waterproof seal, the supplied tiling upstand should be added to the edges of the tray that will be placed against the walls, see separate fitting instructions.

9. Pour assurer l’étanchéité entre le receveur et le mur, les profilés carrelage fournis doivent être fixés sur les bords du receveur qui seront disposés contre les murs. Se référer à la notice d’installation fournie séparément.

11. Ensure the tray is level on all sides.

11. Assurez-vous que le bac soit de niveau de chaque côté.

13. Make good any plaster work prior to tiling.

13. Appliquez un joint silicone avant la pose du carrelage.

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

CROSS SECTION VIEWCROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

6. Joists and purlins must be level on all sides.

6. Les solives et les traverses doivent être d’aplomb de tous les côtés.

®

Access Tray Fitting Instructions for Wooden Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

Access Tray Fitting Instructions for Wooden Floors Receveur Access - Notice d’installation pour sol bois

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

7. Heavy duty method - At each end of tray add purlins between joists. Then add battens to the sides of the joists and form a platform with 18mm plywood level with the top of the joists.

7. Pour assurer l’étanchéité entre le receveur et le mur, les profilés carrelage fournis doivent être fixés sur les bords du receveur qui seront disposés contre les murs. Se référer à la notice d’installation fournie séparément.

8. Joists and plywood must be level on all sides.

8. Les solives et le contreplaqué doivent être d’aplomb de tous les côtés.

English / Français

Page 5: Access Tray Fitting Instructions for Solid Floors - Easa Group

®EASA DEK | Fitting Instructions for Wooden Floors

7. Heavy duty method - At each end of Floor Former add purlins between joists. Then add battens to the sides of the joists and form a platform with 18mm plywood level with the top of the joists.

8. Joists and plywood must be level on all sides.

9. Place the Floor Former gently into position – do not drop as this could cause damage. Polyurethane expanding foam or silicone can be added underneath the floor former as necessary.

10. Ensure the Floor Former is level on all sides. 11. When placing the Floor Former into position ensure the waste fits neatly onto the shower outlet pipe. When the waste is seated in position, use a 3.5mm drill bit to bore through the 4 location holes of the waste flange into the floor former. Be careful not to go too deep as the waste pipe is underneath. Fit self tapping screws provided to secure the waste into place. Do not over-tighten the screws.

12. Mark position of the joists and drill all four sides of the Floor Former into the joists and purlins. The holes must be countersunk to accommodate the screw heads (4.2mm x 60mm recommended screw size).

13. The seam between floor and Floor Former must be completely level. Fill any gaps with polyester filler paste. If required apply tanking system as per manufacturers instructions.

CROSS SECTION VIEW

FILLER

Please Note: Apply sheet flooring or tiles as required using appropriate adhesive. The correct waste (or adaptor) must be used depending on flooring type – see separate waste instructions for fitting waste to appropriate flooring type.

To ensure a waterproof seal a tiling upstand may be added to the edges of the floor former that will be placed against the walls. Optional rigid aluminium or flexible EPDM upstands are available.

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Evolution Grab Rails Fitting Instructions

1. Measure from the floor up to the desired height of the top anchor. Mark with pencil for centre of Anchor plate.

2. For stud walls, place the anchor plate on the stud location and mark the screw holes with a pencil.

Items that may be required:

• Tape measure • Pencil• Variable speed drill • Drill bit set • Screwdriver• Stud finder • Pipe and voltage detector • Masking tape

If the bathroom is being fitted for a particular disabled person, bear in mind their height to consider where the grab rails may be positioned.

Please ensure that the correct type of screws are used for the type of wall and loading required. Do not enlarge any of the grab rail mounting holes nor over-tighten the screws.

Use a pipe and voltage detector to make sure that there are no wires and/or pipes behind the walls where you are seeking to position the grab rails.

For stud walls, locate the wall studs with a stud finder. Place a pencil mark on the stud location. Locate two studs on the wall of the shower based on the length of the handrail. Mark the stud locations with a pencil.

Mark with a pencil the location where you will install the grab rail.

Double check your measurements so that you are completely sure of them before beginning any work.

Easa Export: Tel : +32 (0) 491 330 717 | Fax : +44 (0) 28 92 61 23 26 | Email : [email protected] | Website : www.easagroup.comEasa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.ukEasa Export - Tél: +32 (0) 491 330717 • Télécopie: +44 (0) 28 9261 2326 • Email: [email protected] • Site web: www.easagroup.com

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

10. Apply a high strength filled rubber resin gap filling adhesive between the tray and the floor. This will ensure that the tray is held securely in place. When fitting waste to tray add neutral silicone sealant above and below flat rubber seal. Place the tray gently into position – do not drop as this could cause damage. When bedding into position make sure the outlet pipe fits neatly into the waste.

10. Appliquez un adhésif haute-résistance à base de résine de caoutchouc. Cela assurera que le receveur soit maintenu en place de manière sécurisée. Lors de l’installation de la bonde sur le receveur, ajoutez un joint silicone neutre au-dessus et en dessous du joint plat en caoutchouc. Positionnez doucement le receveur – ne pas le laissez tomber, cela pouvant entraîner des dommages. Lorsque vous couchez le receveur, veillez à ce que la tuyauterie s’adapte parfaitement à la bonde.

12. For recessed trays it is necessary to add plywood sheets followed by vinyl or tiles to bring the floor level up to the same height as the tray.

12. Pour les receveurs encastrés, il est nécessaire d’ajouter des panneaux de contreplaqué recouvert d’un sol vinyle ou carrelage afin de mettre à niveau sol et receveur.

9. To ensure a waterproof seal, the supplied tiling upstand should be added to the edges of the tray that will be placed against the walls, see separate fitting instructions.

9. Pour assurer l’étanchéité entre le receveur et le mur, les profilés carrelage fournis doivent être fixés sur les bords du receveur qui seront disposés contre les murs. Se référer à la notice d’installation fournie séparément.

11. Ensure the tray is level on all sides.

11. Assurez-vous que le bac soit de niveau de chaque côté.

13. Make good any plaster work prior to tiling.

13. Appliquez un joint silicone avant la pose du carrelage.

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

CROSS SECTION VIEWCROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

6. Joists and purlins must be level on all sides.

6. Les solives et les traverses doivent être d’aplomb de tous les côtés.

®

Access Tray Fitting Instructions for Wooden Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

Access Tray Fitting Instructions for Wooden Floors Receveur Access - Notice d’installation pour sol bois

®Access Tray Fitting Instructions for Wooden Floors

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

7. Heavy duty method - At each end of tray add purlins between joists. Then add battens to the sides of the joists and form a platform with 18mm plywood level with the top of the joists.

7. Pour assurer l’étanchéité entre le receveur et le mur, les profilés carrelage fournis doivent être fixés sur les bords du receveur qui seront disposés contre les murs. Se référer à la notice d’installation fournie séparément.

8. Joists and plywood must be level on all sides.

8. Les solives et le contreplaqué doivent être d’aplomb de tous les côtés.

English / Français

Page 6: Access Tray Fitting Instructions for Solid Floors - Easa Group

®

Tel: +44 (0) 28 9261 2500Fax: +44 (0) 28 9261 2326Email: [email protected]: www.easagroup.co.uk

DECLARATION OF CONFORMITY

WE: Easa

Moira Industrial Estate

34 Old Kilmore Road

Moira

Co. Armagh BT67 0LZ

Declare under our sole responsibility that the product:Product: Easa Shower Doors Essence & Evo

Year 07

To which this declaration relates is in conformity with:Annex ZA of EN 14428:2004+A1:2008 Shower Enclosures

Functional requirements and test methods.

Essential Characteristics

Cleanability Pass

Impact resistance/shatter properties Pass

Durability Pass

And meets the requirement of:EU Construction Products Directive (89/106/EC)

The Technical Design File is maintained at:Easa

Moira Industrial Estate

34 Old Kilmore Road

Moira

Co. Armagh BT67 0LZ

Date of Issue: 14-12-09

Place of Issue: Easa, Moira Industrial Estate, 34 Old Kilmore Road, Moira, Co.Armagh BT67 0LZ

Responsible Person: DERON PIRIE

Page 7: Access Tray Fitting Instructions for Solid Floors - Easa Group

®

Tél: +32 (0) 491 330717 Télécopie: +44 (0) 28 9261 2326Email: [email protected] Site web: www.easagroup.com

DECLARATION OF CONFORMITY

Nous, Easa

Moira Industrial Estate

34 Old Kilmore Road

Moira

Co. Armagh BT67 0LZ

Déclarons sous notre seule responsabilité que le produit:Produit: Receveur de douche Easa

Année 07

Au quel cette déclaration se réfère est en conformité avec:L’annexe ZA de EN 14527:2006+A1:2010 Receveurs de douche — Prescriptions fonctionnelles et méthodes d’essai.

Caractéristiques Essentielles

Nettoyabilité Oui

Stabilité du bas Oui

Résistance aux produits chimiques et aux produits tachants Oui

Résistance aux variations de température Oui

Et répond à l’exigence de:La directive européenne Produits de la Construction (89/106/EC)

Documentation technique détenue par:Easa

Moira Industrial Estate

34 Old Kilmore Road

Moira

Co. Armagh BT67 0LZ

Date d’emission: 12-12-11

Lieu d’emission: Easa, Moira Industrial Estate, 34 Old Kilmore Road, Moira, Co.Armagh BT67 0LZ

Responsable dûment habilité: DERON PIRIE

Page 8: Access Tray Fitting Instructions for Solid Floors - Easa Group

®

Access Tray Fitting Instructions for Solid Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

3. Decide on direction of waste and breakout wall if required. For the waste it is necessary to break out 150mm diameter to a depth of 150mm. Repair any damage to damp proof course membrane. Install the waste piping (minimum fall 1 in 40). The waste should line up with the centre of the waste opening in the tray. Please read the separate waste instructions.

3. Décidez du sens de l’évacuation et faites une brèche dans le mur si nécessaire. Pour accueillir la bonde de vidage, il est nécessaire de faire une brèche dont le diamètre et la profondeur seront fonction de la bonde utilisée. Réparez tout dommage à la membrane d’étanchéité. Installez la tuyauterie d’évacuation (pente minimale de 1 pour 40). Celle-ci devra être reliée à la bonde de vidage située au niveau du perçage du receveur. Veuillez-vous référer aux notices livrées séparément avec la bonde de vidage.

4. Add support under the tray by laying a weak concrete mix in excavated area.

4. Ajoutez un support sous le bac en disposant un faible mélange de béton dans la zone décaissée.

Decide whether the tray is going to be installed recessed into the floor (barrier free) or mounted on top of the floor (easy access). If mounting on top of the floor, do not excavate the floor.

Décidez si le receveur sera encastré dans le sol (accès sans obstacle) ou monté en surface (accès facile). Si le receveur est monté en surface, il n’est alors pas nécessaire de toucher au sol existant.

1. Place tray in position and mark out the size on the floor.

1. Positionnez le receveur et délimitez la dimension sur le sol.

2. Break out screed or concrete to a minimum depth of 40mm. Check that the tray fits into the opening.

2. Décaissez la chape ou le béton sur une profondeur minimale de 40mm. Vérifiez que le receveur s’insère dans l’ouverture

®

Access Tray Fitting Instructions for Solid Floors

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

®Evolution Grab Rails Fitting Instructions

1. Measure from the floor up to the desired height of the top anchor. Mark with pencil for centre of Anchor plate.

2. For stud walls, place the anchor plate on the stud location and mark the screw holes with a pencil.

Items that may be required:

• Tape measure • Pencil• Variable speed drill • Drill bit set • Screwdriver• Stud finder • Pipe and voltage detector • Masking tape

If the bathroom is being fitted for a particular disabled person, bear in mind their height to consider where the grab rails may be positioned.

Please ensure that the correct type of screws are used for the type of wall and loading required. Do not enlarge any of the grab rail mounting holes nor over-tighten the screws.

Use a pipe and voltage detector to make sure that there are no wires and/or pipes behind the walls where you are seeking to position the grab rails.

For stud walls, locate the wall studs with a stud finder. Place a pencil mark on the stud location. Locate two studs on the wall of the shower based on the length of the handrail. Mark the stud locations with a pencil.

Mark with a pencil the location where you will install the grab rail.

Double check your measurements so that you are completely sure of them before beginning any work.

Easa Export: Tel : +32 (0) 491 330 717 | Fax : +44 (0) 28 92 61 23 26 | Email : [email protected] | Website : www.easagroup.comEasa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.ukEasa Export - Tél: +32 (0) 491 330717 • Télécopie: +44 (0) 28 9261 2326 • Email: [email protected] • Site web: www.easagroup.com

Access Tray Fitting Instructions for Solid Floors Receveur Access - Notice d’installation pour sol dur Depending on the size, the tray may be heavy, please be careful whilst handling. Protect shower base from damage by using the cardboard packaging.

Selon la taille, il se peut que le receveur soit relativement lourd, veuillez être prudent lors de sa manipulation. Protégez le receveur de douche de tout dommage à l’aide des emballages cartonnés.

ACCESS TRAYS MUST NOT BE CUT

LE RECEVEUR ACCESS NE DOIT PAS ETRE COUPÉ

®

Receveur Access - Notice d’installation pour sol bois

CROSS SECTION VIEW

Easa Export - Tel : +32 (0) 491 330 717 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.com

Easa UK & Ireland - Tel: +44 (0) 28 9261 2500 • Fax: +44 (0) 28 9261 2326 • Email: [email protected] • Website: www.easagroup.co.uk

English / Français