2
HAMILTON CO 2 measurement Accessories & Consumables Conventional mainstream capnography allows only qualitative measurements. State of the art volumet- ric capnography with quantitative CO 2 measurement allows assessment of the metabolism as an early indica- tor of sepsis. HAMILTON MEDICAL ventilators with proximal flow measurement and proximal mainstream CO 2 measure- ment give a valuable insight into patient’s conditions, of- fering real volumetric capnography in mechanical ventila- tion. The CO 2 elimination (V´CO 2 ) allows an assessment of the metabolism. Quantified information about airway dead space (VDaw) and alveolar minute volume (V’alv) is provided in an intuitive way. With the alveolar minute vol- ume you can get a grip on the quality of ventilation. De- tect the start of sepsis through the enhanced metabolic activity indicated through the increase of CO 2 elimination. For applications, where sidestream capnography is stan- dard, the sidestream option provides CO 2 measure- ment with minimal sample flow and minimal added dead space. The full compensation of sampling flow by HAMILTON ventilators, allows the combination of volume target ventilation and capnography, even for neonates. More information: www.hamilton-medical.com Volumetric CO 2 option, an advanced tool for the assessment of ventilation and metabolism

Accessories & Consumables HAMILTON CO2 measurement › web › images › uploads › CO2.pdf · HAMILTON CO2 measurement CO2 main stream and sidestream consumabels REF 281718 HAMILTON

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Accessories & Consumables HAMILTON CO2 measurement › web › images › uploads › CO2.pdf · HAMILTON CO2 measurement CO2 main stream and sidestream consumabels REF 281718 HAMILTON

HAMILTON CO2 measurementAccessories & Consumables

Conventional mainstream capnography allows only qualitative measurements. State of the art volumet-ric capnography with quantitative CO2 measurement allows assessment of the metabolism as an early indica-tor of sepsis.HAMILTON MEDICAL ventilators with proximal flow measurement and proximal mainstream CO2 measure-ment give a valuable insight into patient’s conditions, of-fering real volumetric capnography in mechanical ventila-tion. The CO2 elimination (V´CO2) allows an assessment of the metabolism. Quantified information about airway dead space (VDaw) and alveolar minute volume (V’alv) is

provided in an intuitive way. With the alveolar minute vol-ume you can get a grip on the quality of ventilation. De-tect the start of sepsis through the enhanced metabolic activity indicated through the increase of CO2 elimination.For applications, where sidestream capnography is stan-dard, the sidestream option provides CO2 measure-ment with minimal sample flow and minimal added dead space. The full compensation of sampling flow by HAMILTON ventilators, allows the combination of volume target ventilation and capnography, even for neonates.

More information: www.hamilton-medical.com

Volumetric CO2 option, an advanced tool for the assessment of ventilation and metabolism

Page 2: Accessories & Consumables HAMILTON CO2 measurement › web › images › uploads › CO2.pdf · HAMILTON CO2 measurement CO2 main stream and sidestream consumabels REF 281718 HAMILTON

HAMILTON CO2 measurement

CO2 main stream and sidestream consumabelsREF 281718 HAMILTON mainstream CO2 sensorREF 281719 CO2 adult airway adapter, single-patient use,

box of 10REF 281720 CO2 neonatal airway adapter, single patient use,

box of 10REF 281721 CO2 adult airway adapter, reusable, box of 1REF 281722 CO2 neonatal airway adapter, reusable, box of 1REF 281803 15mm male/female adapter for infant flow sensor,

package of 25REF 281928 HAMILTON sidestream CO2 sensorREF 281929 Sidestream airway adapter adult (10pcs/box)REF 281930 Sidestream airway adapter infant (10pcs/box)REF 281931 Sidestream airway adapter adult with

dehumidification for long term use (10pcs/box)REF 281932 Sidestream airway adapter infant with

dehumidification for long term use (10pcs/box)

Accessories & Consumables

HAMILTON MEDICAL AGVia Crusch 8, CH-7402 Bonaduz, Switzerland

(+41) 81 660 60 10 (+41) 81 660 60 20 [email protected], www.hamilton-medical.com

HAMILTON main streamCO2 sensorMainstream CO2 sensor for volumetric capnography with HAMILTON ventilators.REF 281718

HAMILTON CO2 airway adaptor, disposableFor volumetric capnography at adults and children; option for reduced dead space avail-able for tubes ≤4mm;REF 281719 adults/pediatricsREF 281720 neonates

HAMILTON sidestreamCO2 sensorFor CO2 measurement with sidestream procedure.REF 281928

HAMILTON sidestream airway adaptorFor CO2 monitoring; option for reduced dead space avail-able for tubes ≤4mm;For active humidification, option with filter is available;REF 281931 adults/pediatricsREF 281932 neonates

HAMILTON CO2 airway adaptor, reusableFor volumetric capnography at adults and children; option for reduced dead space avail-able for tubes ≤4mm;REF 281721 adultsREF 281722 neonates

6893

63/0

0 S

pec

ifica

tio

ns

are

sub

ject

to

ch

ang

e w

ith

ou

t n

oti

ce.

©20

11 H

AM

ILTO

N M

EDIC

AL

AG

. All

rig

hts

res

erve

d.

Your contact:

Compatible with the CO2-Option:(Required CO2 preparation kit)