16
Accessories for Sunny Central COMMUNICATION CABINET (COM-C) Technical Description COM-C-TEN084210 | 98-4011910 | Version 1.0 EN

Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Accessories for Sunny CentralCOMMUNICATION CABINET (COM-C) Technical Description

COM-C-TEN084210 | 98-4011910 | Version 1.0 EN

Page 2: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties
Page 3: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Table of Contents

Technical Description COM-C-TEN084210 3

Table of Contents1 Product Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62.1 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82.2 Interior View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 103 Mounting the Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123.1 Mounting the Communication Cabinet (indoor version). . . . . . 123.2 Mounting the Communication Cabinet (outdoor version). . . . . 134 Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Page 4: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Table of Contents SMA Solar Technology AG

4 COM-C-TEN084210 Technical Description

Page 5: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Product Details

Technical Description COM-C-TEN084210 5

1 Product DetailsThe communication distribution box, Communication Cabinet, from SMA Solar Technology serves as cabling for all communication components that are used in large-scale PV systems with Sunny Central inverters.

• The Communication Cabinet allows up to 150 participants to be connected in an Ethernet-based communication system.

• The distributor is available for both indoor and outdoor installation as well as for base and wall mounting.

• The standard distributor is equipped with protective contact plugs (e.g. for the attachment of plug-in power supply units) as well as a 230 V/24 V power supply unit; all additional components can be ordered optionally from SMA Solar Technology.

• The Communication Cabinet is supplied via an external power supply voltage. The Sunny Central inverters can be connected using CAT cables or using fiber optic cables for greater distances. The data is acquired using the optionally available WebBox.

• The data for remote monitoring is transferred using the optional selectable router. The data can be transferred wirelessly over GSM/GPRS or using a telephone connection. When transmitting via GSM/GPRS, an external GSM antenna is included with delivery.

Page 6: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Technical Data SMA Solar Technology AG

6 COM-C-TEN084210 Technical Description

2 Technical Data COM-C :

HousingOutdoor installation YesUV resistant Yes, outdoor version only (optional)Base installation Yes, outdoor version only (optional)Wall mounting Yes (optional with outdoor version)Material (outdoor version) Polyester (fiberglass-reinforced)Material (indoor version) Sheet steelColor scheme (outdoor version) RAL 7035, light gray, solid-coloredColor scheme (indoor version) RAL 7035 structureCombustion properties (outdoor version) self-extinguishing, halogen-freeCombustion properties (indoor version) non-combustibleLock cylinder (switch cabinet key, double-bit) prepared for customer mountingCable retention rail Yes, for base mounting onlyDimensions and weightOutdoor housing (w x h x d in mm) 1000 x 750 x 320Indoor housing (w x h x d in mm) 760 x 760 x 300Base (w x h x d in mm) 1100 x 940 x 310Weight (outdoor version) approx. 40 kg (depending on equipment)Weight (indoor version) approx. 50 kg (depending on equipment)Weight (base) 25 kgInput data:Nominal voltage 230 V, 50/60 HzNominal current 1.0 AMax. back-up fuse 16 AConnection 3-wire connection terminal

(0.08 - 2.5 mm2; Cage Clamp)

Page 7: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Technical Data

Technical Description COM-C-TEN084210 7

Standard equipmentProtective contact plugs 5 unitsPower supply unit 1 x 230 V AC / 24 V DCOptional equipmentGSM/GPRS router including external antenna Max. 2 units ISDN router Max. 2 units DSL router Max. 1 unitDSL modem Max. 1 unitSunny WebBox Max. 3 units Ethernet 8-port switch Max. 4 unitsMedia converter (multi- or single mode) RJ45 / optical fiber

Max. 4 units

Interfaces (according to chosen option)Communication RJ 45 / Ethernet or optical fiberStandardsEC Declaration of Conformity YesProtection Rating and Ambient ConditionsProtection rating in accordance with DIN EN 60529

IP 54

Permissible ambient temperature [T] –20 °C ... +50 °CRelative humidity, [Uair] (non-condensing) 10 ... 90 %

COM-C :

Page 8: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Technical Data SMA Solar Technology AG

8 COM-C-TEN084210 Technical Description

2.1 DimensionsCommunication Cabinet (indoor version for wall mounting)

Page 9: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Technical Data

Technical Description COM-C-TEN084210 9

Communication Cabinet (outdoor version with base)

Page 10: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Technical Data SMA Solar Technology AG

10 COM-C-TEN084210 Technical Description

2.2 Interior ViewCommunication Cabinet (indoor version) with maximum assembly options(Assembly depends on assembly variants)

Page 11: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Technical Data

Technical Description COM-C-TEN084210 11

Communication Cabinet (outdoor version) with maximum assembly options(Assembly depends on assembly variants)

Page 12: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Mounting the Device SMA Solar Technology AG

12 COM-C-TEN084210 Technical Description

3 Mounting the Device3.1 Mounting the Communication Cabinet (indoor version)1. Mark the position of the drill holes.

2. Drill holes at the marked points.3. Open the Communication Cabinet.4. Attach the Communication Cabinet to the wall using suitable screws and washers.5. Check that the unit is securely in place.6. Close the Communication Cabinet.☑ The Communication Cabinet is mounted on the wall.

Page 13: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Mounting the Device

Technical Description COM-C-TEN084210 13

3.2 Mounting the Communication Cabinet (outdoor version)1. Attach the enclosed mounting plates to the Communication Cabinet. You have the possibility of

fitting the mounting plates vertically or horizontally to the Communication Cabinet.2. Mark the position of the drill holes.

3. Drill holes at the marked points.4. Attach the Communication Cabinet to the wall using suitable screws and washers.5. Check that the unit is securely in place.☑ The Communication Cabinet is mounted on the wall.

Page 14: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

Contact SMA Solar Technology AG

14 COM-C-TEN084210 Technical Description

4 ContactFor technical problems with our products, contact the SMA Service Line. We will need the following information in order to provide you with the necessary assistance:

• Serial number of the Communication Cabinet• Option code

SMA Solar Technology AG Sonnenallee 134266 Niestetal, GermanyTel. +49 561 9522 299Fax +49 561 9522 3299 [email protected] www.SMA.de

The above data is given on the name plate.The name plate is found inside the Communication Cabinet.

Page 15: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG Legal Restrictions

Technical Description COM-C-TEN084210 15

The information contained in this document is the property of SMA Solar Technology AG. Publishing its content, either partially or in full, requires the written permission of SMA Solar Technology AG. Any internal company copying of the document for the purposes of evaluating the product or its correct implementation is allowed and does not require permission.

Exclusion of liabilityThe general terms and conditions of delivery of SMA Solar Technology AG shall apply.The content of these documents is continually checked and amended, where necessary. However, discrepancies cannot be excluded. No guarantee is made for the completeness of these documents. The latest version is available online at www.SMA.de or from the usual sales channels.Guarantee or liability claims for damages of any kind are excluded if they are caused by one or more of the following: • Damages during transportation• Improper or inappropriate use of the product• Operating the product in an unintended environment• Operating the product whilst ignoring relevant, statutory safety regulations in the deployment location• Ignoring safety warnings and instructions contained in all documents relevant to the product• Operating the product under incorrect safety or protection conditions• Altering the product or supplied software without authority• The product malfunctions due to operating attached or neighboring devices beyond statutory limit values• In case of unforeseen calamity or force majeureThe use of supplied software produced by SMA Solar Technology AG is subject to the following conditions:• SMA Solar Technology AG rejects any liability for direct or indirect damages arising from the use of software developed by

SMA Solar Technology AG. This also applies to the provision or non-provision of support activities.• Supplied software not developed by SMA Solar Technology AG is subject to the respective licensing and liability agreements

of the manufacturer.

SMA Factory WarrantyThe current guarantee conditions come enclosed with your device. These are also available online at www.SMA.de and can be downloaded or are available on paper from the usual sales channels if required.

TrademarksAll trademarks are recognized even if these are not marked separately. Missing designations do not mean that a product or brand is not a registered trademark.SMA Solar Technology AGSonnenallee 134266 NiestetalGermanyTel. +49 561 9522-0Fax +49 561 9522-100www.SMA.deE-Mail: [email protected]© 2004 to 2008 SMA Solar Technology AG. All rights reserved

Page 16: Accessories for Sunny Central COMMUNICATION CABINET …files.sma.de/dl/8226/COM-C-TEN084210.pdf · 2020-03-03 · Color scheme (indoor version) RAL 7035 structure Combustion properties

SMA Solar Technology AG

Sonnenallee 1

34266 Niestetal, Germany

Tel.: +49 561 9522 4000

Fax: +49 561 9522 4040

E-Mail: [email protected]

Freecall: 0800 SUNNYBOY

Freecall: 0800 78669269

www.SMA.de