DSF5ZEM-K002 06/2008 COMBIVERT GB INSTRUCTION MANUAL Encoder Interface Channel 1 variable Channel 2 SSI

COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

DSF

5ZEM

-K00

2

06/2008

COMBIVERT

GB INSTRUCTION MANUAL Encoder Interface

Channel 1 variableChannel 2 SSI

Page 2: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical
Page 3: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

Table of Contents

GB -

1. Safety Instructions ........................................................................................ 41.1 Validity ................................................................................................................41.2 Qualification ........................................................................................................4

2. Product Description ....................................................................................... 52.1 General ...............................................................................................................52.2 Material number .................................................................................................52. Scope of delivery (option or replacement delivery) ............................................62.4 Mechanical installation .......................................................................................6

. Description of the Interface ........................................................................... 6.1 Voltage supply ....................................................................................................6.2 Channel 1 ...........................................................................................................6. Channel 2 ...........................................................................................................7..1 Specification channel 2 ......................................................................................7..2 Description of socket XB ..................................................................................7.. Input signals channel 2 .......................................................................................7...1 Serial data transmission .....................................................................................7...2 Encoder breakage recognition ...........................................................................8..4 Connection of the encoder .................................................................................9..5 Encoder cable ..................................................................................................10..6 Encoder line length ...........................................................................................11

4. Start-up ....................................................................................................... 11

5. Error Messages ........................................................................................... 11

Page 4: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

GB-4

1. Safety InstructionsPrior to performing any work on the unit the user must familiarize himself with the unit. This includes especially the knowledge and observance of the safety and warning directions. The pictographs used in this Instruction Manual have following meaning:

Danger Refers to danger of life by electric current.

Warning Refers to possible danger of injury or life.

Note Refers to tips and additional information.

1.1 ValidityThe information contained in the technical documentation, as well as any user-specific advice in spoken and written and through tests, are made to best of our knowledge and information about the application. However, they are considered for information only without responsibility. This also applies to any violation of industrial property rights of a third-party. Inspection of our units in view of their suitability for the intended use must be done generally by the user. Inspections are particulary necessary, if changes are executed, which serve for the further development or adaption of our products to the applications (hardware, software or download lists). Inspections must be re-peated completely, even if only parts of hardware, software or download lists are modified.

Controlling by the user

Application and use of our units in the target products is outside of our control and therefore lies exclusively in the area of responsibility of the user.

Use under spe-cial conditions

The used semiconductors and components of KEB are developed and dimensio-ned for the use in industrial products. If the KEB COMBIVERT is used in machi-nes, which work under exceptional conditions or if essential functions, life-sup-porting measures or an extraordinary safety step must be fulfilled, the necessary reliability and security must be ensured by the machine builder.

1.2 QualificationAll operations serving transport, installation and commissioning as well as maintenance are to be carried out by skilled technical personnel (observe IEC 64 or CENELEC HD 84 or DIN VDE 0100 and national accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical training and experience and those with knowledge of the relevant standards and who are familiar with the field of power transmission (VDE 0100, VDE 0160 (EN 50178), VDE 011 (EN 60204) as well as the approporiate regulations for your area.

Danger by high voltage

KEB electronics components contain dangerous voltages which can cause death or serious injury. In operation, drive converters, depending on their degree of protection, may have live, uninsulated, and possibly also moving and hot surfaces.In case of inadmissible removal of the required covers, of improper use, wrong installation or maloperation, there is the danger of serious personal injury and damage to property.

Page 5: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-5

2. Product DescriptionFigure 1: SSI - Encoder interface at channel 2

XB XAChannel 2 Channel 1

SSI variableSynchronous Serial Interface see material number

2.1 GeneralEach of the interface cards delivered by KEB include two interfaces. As there are numerous different combinations available each interface will be described by means of separate instructions. The instruction covers the installation of the interface card, the connection as well as the start-up of a suitable encoder. Further information and the parameter adjust-ments are described in the application manual for the inverter/servo.

2.2 Material numberxM F5 K8x X X X X

Term of delivery 0 installed Z Option, spare part

1 SIN/COS 5 Resolver EnDat L HTL input without

inverse signals4 TTL-input

F5 Series

applicable for housing size 1M D, E (PCB 1M.F5.280-1015/ -0025/ -4017/ -2020/ -2021)

2M G…U (PCB 2M.F5.280-1015/ -2020/ -2021)

Page 6: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-6

2. Scope of delivery (option or replacement delivery)• Encoder Interface• two instruction manuals• fixing bolt• packing material

2.4 Mechanical installationAll kind of works on the inverter may be carried out by authorized personnel in accordance with the EMC and safety rules only.• Switch inverter de-energized and await capacitor discharge time• Pull off operator• Remove plastic cover• Remove fixing bolt• Fix interface board beginning from the socket connector straightly• Screw in fixing bolt• Attach plastic cover

. Description of the Interface.1 Voltage supply

Figure .1 Voltage supply of control and encoder interfaces

Uint 24 VDC Internal voltage supply of COMBIVERT.

X2A

X3A

X3B5,2V

24V5V

24V5V

Uint

Iint120 mA at Hiperface, Sin/Cos, EnDat and SSI-Sin/

Cos.170 mA at all other encoder interfaces.

UextControl terminal strip (X2A) of the COMBIVERT with external voltage supply 24…0 DCV.

24 V Voltage output of encoder interfaces XA and XB for encoder supply.

I24V

Current Iint reduces itself by draw current to the 5 V-out-put in accordance with the following formula:

5,2 V x I5VI24V = Iint - –––––––––Uint

5 V Voltage output for encoder supply. 5,2 V are obtained from the 24 V voltage.

I5V

00 mA at Hiperface, Sin/Cos, EnDat and SSI-Sin/Cos.

500 mA at all other encoder interfaces.

1 A at external supply (dependent on voltage source)

.2 Channel 1The description of input XA is depending on the used encoder interface. It is described in a separate manual.

Page 7: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-7

. Channel 2

..1 Specification channel 2Socket XB SUB-D9Interface type SSI (synchronous serial interface)Input signals 5 V TTL according to RS485Outputs and inputs Clock+, Clock-, Data+, Data-Code Binary coded, Gray CodeResolution 12 Bit Singleturn, 12 Bit MultiturnLimiting frequency 220 kHz

Increments per revolution 1…168 inc (recommendation 2500 inc for speed upto 4500 rpm

Input resistance 150 Ω

Max. line length 50 m, the value is additionally limited by the signal fre-quency, cable capacity and supply voltage.

..2 Description of socket XBFigure ..1 Socket XB

5 4 3 2 1

9 8 7 6

PIN Name Description1 CL+ Output of the clock signal2 DAT+ Input data track – –4 5 V Voltage output 5 V5 24 V Voltage output 20…0 V6 CL- Difference signal to clock signal C+7 DAT- Difference signal to data track DAT+8 – –9 COM Reference potential for voltage supply– GND Connection for shield at connector housing - is directly connected with

the inverter earth.

.. Input signals channel 2

...1 Serial data transmissionSingleturn absolute encoder divide one revolution of the shaft into a defined number of measuring steps. This are 4096 positions at a SSI protocol, corresponding to a resolution of 12 Bit. Multiturn absolute encoder do not only detect angle positions within one revolution but also the number of revolutions. With a resolution of the multiturn part of 12 Bit this cor-

Page 8: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-8

responds to 4096 revolutions. The position measuring area of 0…224-1 should not be left, since an overflow and/or underflow is not evaluated as error. A system offset can be defined by writing on Ec.4 or approaching to reference point.

Figure ...1 Serial data transmission with SSI encoder

Clock signal

Data

Monoflop

Position data

P: Parallel position dataT: Period

Tp: Clock interruption up to the next requesttm: Pulse duration of the monofloptv: Deceleration time

Dhigh: most significant position bitDlow: least significant position bit

...2 Encoder breakage recognitionAn error bit is evaluated for monitoring of the encoder at channel 2. The monitoring is swit-ched on/off with parameter Ec.42 (Ec.20 up to V2.8). The recognition of encoder breakage triggers an „error! encoder 1“ (value 2).

Page 9: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-9

..4 Connection of the encoder• Encoder cable double-shielded and twisted in pairs• Connect exterior shielding at both ends to PE/GND• Connect interior shieldings at one side to COM• Do not connect exterior and interior shielding

Two connection examples of SSI encoders are following. The assignment of the motor en-coder interface is different according to the manufacturer. The examples must be adopted accordingly.

Picture ..4.a Connection example: Encoder with 18V supply (e.g. Sick-Stegmann AG615)

Encoder plug Socket XB

5 4 3 2 1

9 8 7 6

Name PIN Material number: 00F4609-xxxx PIN Core colorGND – – exterior shielding

CL+ 1 greenCL- 11 6 yellow

Data+ 2 2 blueData- 10 7 redCOM 1 9 white + internal shiel-

ding24 V 8 5 brown

Page 10: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-10

Picture ..4.b Connection example: Encoder with 5V supply (e.g. Kübler 9081)

Encoder plug Socket XB

5 4 3 2 1

9 8 7 6

Name PIN Material number: 00F4909-xxxx PIN Core colorGND – – Solder external shielding

to metal housing

CL+ 1 greenCL- 4 6 yellow

Data+ 5 2 blueData- 6 7 redCOM 1 9 white + internal shiel-

ding5 V 2 4 brown

..5 Encoder cableKEB delivers ready-made encoder cable in accordance with the following number code:For Stegmann encoder:

00F4609-xPxx x,xx m z.B. 00F4609-0P60 corresponds to 0,60 m00F4609-0xxx xxx m z.B. 00F4609-0040 corresponds to 40 m

For Kübler encoder:00F4909-xPxx x,xx m z.B. 00F4909-0P60 corresponds to 0,60 m00F4909-0xxx xxx m z.B. 00F4909-0040 corresponds to 40 m

KEB encoder cables are corresponding to the following specification:Signal lines x (2 x 0,14 mm²)Supply lines 2 x 0,5 mm²

Particularities trailing capable, oil-resistantTemperature range constant upto 80 °C

Color green RAL 6018

Page 11: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

SSI - Encoder interface at channel 2

GB-11

..6 Encoder line lengthThe maximum line length for the connection line is limited by the signal frequency, cable capacity and the line resistance.

Encoder cable length =U - Umin––––––––––Imax • 2 • R

max. encoder current Imax: see encoder descriptionSupply voltage U: Voltage output

min. supply voltage Umin: see encoder descriptionKEB encoder cable resistance R: 0,06 Ω/m at 0,5 mm²

4. Start-upAfter the installation or exchange of an encoder interface some adjustments of the inverter/servo software have to be done before operation:• Switch on inverter• Select application mode• Select parameter Ec.10 and control whether value „6: SSI“ is entered. The

displayed value has to be confirmed by „ENTER“ in any case.• Select parameter Ec.11 and adjust the increments per revolution to 1024.• Select parameter Ec.17 and adjust 4-fold evaluation (1024 inc x 4 = 4096 inc)• Select Ec.42 (Ec.20 upto V2.8) and adjust the encoder breakage recognition

dependent on the case of operation.• Select parameter Ec.21 and adjust multiturn resolution (standard 12 Bit); ad-

just „0“ for singleturn encoders.• Select parameter Ec.22 and adjust clock frequency for SSI encoder.• Select parameter Ec.2 and adjust data format (standard Gray-Code).• Ec.0 displays the read out position of the SSI encoder.• A system offset can be defined by writing on parameter Ec.4 or approaching

to reference point.

5. Error MessagesError messages and their meaning are described in Chapter 9 of the application manual.

Page 12: COMBIVERT€¦ · accident prevention rules!). According to this manual qualified staff means those who are able to recognise and judge the possible dangers based on their technical

© K

EB

D

SF5

ZEM

-K00

2 06

/200

8

Karl E. Brinkmann GmbHFörsterweg 36-38 • D-32683 Barntrup

fon: +49 5263 401-0 • fax: +49 5263 401-116net: www.keb.de • mail: [email protected]

KEB Antriebstechnik GmbH & Co. KGWildbacher Str. 5 • D–08289 Schneebergfon: +49 3772 67-0 • fax: +49 3772 67-281

mail: [email protected]

KEB Antriebstechnik Austria GmbHRitzstraße 8 • A-4614 Marchtrenk

fon: +43 7243 53586-0 • fax: +43 7243 53586-21net: www.keb.at • mail: [email protected]

KEB AntriebstechnikHerenveld 2 • B-9500 Geraadsbergen

fon: +32 5443 7860 • fax: +32 5443 7898mail: [email protected]

KEB Power Transmission Technology (Shanghai) Co.,Ltd.No. 435 Xipu Road, Songjiang Industrial Zone,

CHN-201611 Shanghai, P.R. Chinafon: +86 21 37746688 • fax: +86 21 37746600

net: www.keb.cn • mail: [email protected]

KEB Antriebstechnik Austria GmbHOrganizační složka

K. Weise 1675/5 • CZ-370 04 České Budějovicefon: +420 387 699 111 • fax: +420 387 699 119net: www.keb.cz • mail: [email protected]

KEB EspañaC/ Mitjer, Nave 8 - Pol. Ind. LA MASIA

E-08798 Sant Cugat Sesgarrigues (Barcelona)fon: +34 93 897 0268 • fax: +34 93 899 2035

mail: [email protected]

Société Française KEBZ.I. de la Croix St. Nicolas • 14, rue Gustave Eiffel

F-94510 LA QUEUE EN BRIEfon: +33 1 49620101 • fax: +33 1 45767495

net: www.keb.fr • mail: [email protected]

KEB (UK) Ltd.

6 Chieftain Buisiness Park, Morris ClosePark Farm, Wellingborough GB-Northants, NN8 6 XF

fon: +44 1933 402220 • fax: +44 1933 400724net: www.keb-uk.co.uk • mail: [email protected]

KEB Italia S.r.l.Via Newton, 2 • I-20019 Settimo Milanese (Milano)

fon: +39 02 33535311 • fax: +39 02 33500790net: www.keb.it • mail: [email protected]

KEB Japan Ltd.15–16, 2–Chome, Takanawa Minato-ku

J–Tokyo 108-0074fon: +81 33 445-8515 • fax: +81 33 445-8215

mail: [email protected]

KEB Korea SeoulRoom 1709, 415 Missy 2000

725 Su Seo Dong, Gang Nam GuROK-135-757 Seoul/South Korea

fon: +82 2 6253 6771 • fax: +82 2 6253 6770mail: [email protected]

KEB RUS Ltd.Krasnokazarmeny proezd 1, Metrostation „Aviamotornay“

RUS-111050 Moscow / Russiafon: +007 445 695 3912 • fax: +007 495 645 3913

mail: [email protected]

KEB SverigeBox 265 (Bergavägen 19)

S-43093 Hälsöfon: +46 31 961520 • fax: +46 31 961124

mail: [email protected]

KEB America, Inc.5100 Valley Industrial Blvd. South

USA-Shakopee, MN 55379fon: +1 952 224-1400 • fax: +1 952 224-1499

net: www.kebamerica.com • mail: [email protected]