Action Plan for Fire Fighting (2)

Embed Size (px)

Citation preview

  • 7/29/2019 Action Plan for Fire Fighting (2)

    1/10

    ACTION PLAN FOR FIRE FIGHTING

  • 7/29/2019 Action Plan for Fire Fighting (2)

    2/10

    Information inInformation in casecase ofof firefire at House of Swedenat House of Sweden

    RecommendedRecommended entranceentrance forfor firefightingfirefighting -- notenote thethe drawingsdrawings

    NoteNote separate instructions forseparate instructions for firefightingfirefighting whenwhen thethe floodproofingfloodproofing isis mountedmounted

    ParticularParticular risks in therisks in the buildingbuilding ((notenote thethe drawingsdrawings))

    The receptionist (The receptionist (dresseddressed with redwith red vestvest) gives information of) gives information of evacutionevacution status.status.

    TelephonenumberTelephonenumber toto contactpersoncontactperson inin seperateseperate listlist

    TheThe reassamblyreassambly placeplace isis situatedsituated closeclose to theto the boathouseboathouse by the Potomac riverby the Potomac river

    The sprinklercentral iThe sprinklercentral i locatedlocated in the 1st floorin the 1st floornotenote thethe drawingsdrawings

    Start and stop of fan forStart and stop of fan for firegasventilationfiregasventilation of atrium,of atrium, notenote separat instructionseparat instruction

    PredistinedPredistined placesplaces insideinside andand closeclose to theto the buildingbuilding for the first information to thefor the first information to theevacuatedevacuated personspersonsnotenote thethe drawingsdrawings

    Areas in theAreas in the buildingbuilding andand objectsobjects thatthat needneed extraextra attentionattentionnotenote this symbol inthis symbol in

    thethe drawingsdrawings

    SP

  • 7/29/2019 Action Plan for Fire Fighting (2)

    3/10

    Maximum of 200

    guests och occupants

    Open roof terrace6th

    floor

    Approx. 20 residents

    and 5 workspaces.

    8 apartments. One apartment is

    combined with an office

    5th

    floor

    Approx. 20 residents

    and 5 workspaces

    9 apartments. One apartment is

    combined with an office

    4th

    floor

    37 workspacesOffice for Ministry of Foreign AffairsOne floor above the entrance floor3rdfloor

    180 temporarypersons and 10

    workplaces

    Entrance, two receptions ( entrance forMinistry for Foreign Affairs and oneentrance for other visitors) exhibition hall

    and one of the Ministry for F. A. offices.

    Ground- and entrance floor

    2ndFloor

    320 temporarypersons

    Technical rooms, storerooms, catering

    pantry, office, auditorium, conferencecentre and exhibition hall.Split level floor1 stfloor

    A few occupantsstaying temporarily

    Parking for approx. 75 cars and a smallstore room

    Under ground connecting HoS with the otherhouse on the same property

    Parkinglevel

    Number of occu-pantsin roomActivitiesPart of buildingFloor

    DESCRIPTION OF ACTIVITIES AND MAXIMUM NUMBER OF PERSONS PER FLOOR

  • 7/29/2019 Action Plan for Fire Fighting (2)

    4/10

    Action plan for parking level

    Fire resistance rated walls. Least 2 hrs ( 120 min)

  • 7/29/2019 Action Plan for Fire Fighting (2)

    5/10

    Action plan for 1st floorWay of attack

    SP

    SP Placing of watersprinkle-

    central

    Priority rooms

    when fire fighting

    ElectricalFire resistance rated walls 120 minutes

    Stan

    dpip

    esystem

    Fire inlet/ outlet Fire

    inlet/

    outl

    et

  • 7/29/2019 Action Plan for Fire Fighting (2)

    6/10

    Fire resistancerated walls 2 hrs

    Action plan for 2nd floor

    Way of attack

    Sliding glass panel

    Priority rooms whenfire fighting

    Areas marked with this colour demand special entrance

    permission before a rescue action

    CAPlacing of the centralizedcontrol for the fire alarmFire comand center

    CA

    24 hrs manning reception

    office hrs manning reception

    CA

    Sta

    ndpipe

    system

  • 7/29/2019 Action Plan for Fire Fighting (2)

    7/10

    Action plan for 3rd floor

    Priority area in case of fire fighting

    The entire third floor ( except the stairwell and the elevator pit)

    demand special entrance permission before a rescue action)

    Fire resistance rated walls. Least 2 hrs ( 120 min)

    Stan

    dpip

    esyst

    em

  • 7/29/2019 Action Plan for Fire Fighting (2)

    8/10

    Fire cell limit

    Action plan for 4th floor

    Fire resistance rated walls. Least 2 hrs ( 120 min)Fire resistance rated walls. Least 2 hrs ( 120 min)

    Stan

    dpip

    esyst

    em

  • 7/29/2019 Action Plan for Fire Fighting (2)

    9/10

    Fire resistance rated walls. Least 2 hrs ( 120 min)

    Action plan for 5th floor

    Stan

    dpipe s

    yste

    m

  • 7/29/2019 Action Plan for Fire Fighting (2)

    10/10

    Action plan for open floor terrace ( 6th floor)

    Stan

    dpip

    esyst

    em