8/7/2019 AcuSolve Biomed Examples http://slidepdf.com/reader/full/acusolve-biomed-examples 1/21 Page 1 ACUSIM Software Confidential Information AcuSolve Examples – Blood Pump AcuSolve Examples – Blood Pump n The power law blood damage model gives excellent agreement with the data. Pressure contours on blade surfaces

AcuSolve Biomed Examples

Embed Size (px)

Citation preview

Page 1: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 1/21

Page 1ACUSIM Software Confidential Information

AcuSolve Examples – Blood PumpAcuSolve Examples – Blood Pump

n The power law blood damagemodel gives excellentagreement with the data.

Pressure contours on blade surfaces

Page 2: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 2/21

Page 2ACUSIM Software Confidential Information

LVAD (heart pump!)LVAD (heart pump!)

n

ASAIO Journal – 2007Development and Validation of a Computational FluidDynamics

Methodology for Simulation of Pulsatile Left Ventricular AssistDevices

Authors: Richard B. Medvitz*‡, Eric G. Paterson*‡, James W. Kreider†, Keefe B.Manning†, Arnold A. Fontaine*†, Steven Deutsch*†

Institutional Affiliation: * Applied Research Laboratory, The Pennsylvania StateUniversity, University Park, Pa 16802

Page 3: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 3/21

Page 3ACUSIM Software Confidential Information

Example of Mesh Motion for PumpExample of Mesh Motion for Pump

Page 4: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 4/21

Page 4ACUSIM Software Confidential Information

Unstructured MeshUnstructured Mesh Computational velocity magnitude contours andComputational velocity magnitude contours andtangential velocity vectors at 6 mm from the fronttangential velocity vectors at 6 mm from the frontface of the LVAD with the mitral and aortic valvesface of the LVAD with the mitral and aortic valves

removedremoved..

Page 5: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 5/21

Page 5ACUSIM Software Confidential Information

Blood/Cancer Cell InteractionBlood/Cancer Cell Interaction http://www.ensight.com/cutting-edge-cfd-simulations-take-cancer-http://www.ensight.com/cutting-edge-cfd-simulations-take-cancer-research-to-a-new-dimension.htmlresearch-to-a-new-dimension.html

Meghan Hoskins, a Ph.D. candidate in the Bioengineering program at PennState, under the advisement of Robert Kunz, Ph.D. and Cheng Dong,Ph.D., is examining how cancer cells stick to white blood cells, thedefenders of the blood stream, and how the flow of blood affects thisadhesion. Her work, funded by the National Cancer Institute and the PSU Applied Research Laboratory, is based on the theory that, as cancer cellstravel through the blood stream, they are attracted to areas where white

blood cells are at work fighting inflammation. 

Cancer Cell

Traverseswhite blood cell

Page 6: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 6/21

Page 6ACUSIM Software Confidential Information

Cell WorkflowCell Workflow

Page 7: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 7/21

Page 7ACUSIM Software Confidential Information

Lung AirflowLung Airflow

Figure 1: Virtual 3-D Airway TreeGeometry

Model which has 54,611 branches 

Figure 2 shows the wall pressure

distribution for that 3500 branches. Thescale on the model is -0.08 (blue) to 3.35(red) Pascals. Meshing and solving of thefull virtual model is currently underway

Page 8: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 8/21

ACUSIM Software Confidential Information

Adominal Aortic AneurysmAdominal Aortic AneurysmN u m C r

国立がんセンター

がん予防・ 診研究セン検ター

山本 修司 先生

SPIE 2006

Pre-operative Post Operative

解析メッシュ  節点数 177,719  要素数 958,738  4節点四面体( amira 使用 )

領域分割数 1非定常解析

  400 steps (4 心拍)  428 MB  11.1Hr 

解析メッシュ  節点数 189,918  要素 1,015,905  4節点四面体( amira 使用 )

領域分割数 1非定常解析

  400 steps (4 心拍)  456 MB  13.1 Hr 

Page 9: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 9/21

ACUSIM Software Confidential Information

N u m C r

The bloodstream analysis of the cerebral aneurysmThe bloodstream analysis of the cerebral aneurysm

inlet

outlet1

outlet2

outlet3

浜松医科大学

医学部放射線医学講座

礒田 治夫 先生

Page 10: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 10/21

ACUSIM Software Confidential Information

N u m C rFlow Analysis in Cerebral AneurysmFlow Analysis in Cerebral Aneurysm ))

流線

解析メッシュ  節点数 90,398  要素数 385,490  4節点四面体( amira 使用 )

領域分割数 4非定常解析

  300 steps   (3 心拍)  69.6 MB/cpu

  1.97 Hr 

領域分割数 1189 MB6.87 Hr 

Page 11: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 11/21

ACUSIM Software Confidential Information

Animation of Flow in Aneurysms

Page 12: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 12/21

ACUSIM Software Confidential Information

Blood fill from sending blood vesselBlood fill from sending blood vesselN u m C r

岐阜県立多治見病院心臓血管外科

徳田順之 先生

External Circulation from heart lung machine

送血管の例

4.1 l/min

The Gifu prefectural Tajimi hospitalheart blood vessel surgery

Page 13: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 13/21

ACUSIM Software Confidential Information

Blood FillBlood Fill (( continuedcontinued ))

3.0 m/sec 2.0 m/sec 0.5 m/sec

Mesh Detailsnodes   321,678elements 1,806,203 (4 node tet)

Step1 : Steady State run for initial condition for Step 2Step2 : Transient DES Turb. Model

リスタート  100 steps  

250 MB/CPU  5.9 Time

Page 14: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 14/21

ACUSIM Software Confidential Information

Case StudyCase StudyPeristaltic PumpsPeristaltic Pumps

Ø Inert/Sterile FluidsInert/Sterile Fluids

Ø Biomedical devices to corrosive fluids in chemical industriesBiomedical devices to corrosive fluids in chemical industriesUses “peristalsis” processUses “peristalsis” process

Ø Tubing under compression causes fluid to flowTubing under compression causes fluid to flow

Ø As Tubing returns to natural state, flow is induced to the puAs Tubing returns to natural state, flow is induced to the pu

An FSI study is required to predict the pump flow characteristicsAn FSI study is required to predict the pump flow characteristics

Compr essi

onRestitution

Flow in

Flow out

Page 15: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 15/21

ACUSIM Software Confidential Information

Peristaltic Pump ModelPeristaltic Pump Model

Structural ModelStructural ModelDynamic Explicit AnalysisDynamic Explicit Analysis

Flexible Hose Modelled as Rubber Flexible Hose Modelled as Rubber 

Ø Hyperelastic propertiesHyperelastic properties

Ø CC1010

=69000, C=69000, C0101

=173000,=173000,

DD11=1.45e=1.45e-8-8

36828 Linear Hexahedral Elements36828 Linear Hexahedral Elements

Total solution time = 6.1 sTotal solution time = 6.1 s

Angular velocity: 10.472 radians/secAngular velocity: 10.472 radians/sec

Casing and rollers modelled as rigidCasing and rollers modelled as rigidØ Casing and ends are fixedCasing and ends are fixed

Page 16: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 16/21

ACUSIM Software Confidential Information

Fluid ModelFluid ModelTransient analysisTransient analysis

Fluid properties to be viscous oilFluid properties to be viscous oilØ Density: 980 kg/mDensity: 980 kg/m33

Ø Viscosity: 0.5 kg/mViscosity: 0.5 kg/mss

Spalart-AllmarasSpalart-Allmaras turbulence modelturbulence model

72100 Linear Hexahedral Elements72100 Linear Hexahedral Elements

Inflow: Velocity-inlet conditionInflow: Velocity-inlet condition

Ø Initial stagnant conditionInitial stagnant condition

Outflow: Pressure-outlet conditionOutflow: Pressure-outlet conditionØ Outlet set to atmosphericOutlet set to atmospheric

pressurepressure

Peristaltic Pump ModelPeristaltic Pump Model

Page 17: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 17/21

ACUSIM Software Confidential Information

Enabling FSI Solutions with Abaqus/CAEEnabling FSI Solutions with Abaqus/CAE

FSI module available for Abaqus/CAEFSI module available for Abaqus/CAE

Ø

Easy-to-use workflow for FSIEasy-to-use workflow for FSIModule provides specific functionality for defining FSI modulesModule provides specific functionality for defining FSI modules

CFD Product supportCFD Product support

Ø AcuSolveAcuSolve

Page 18: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 18/21

ACUSIM Software Confidential Information

FSI WorkflowFSI Workflow

Page 19: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 19/21

ACUSIM Software Confidential Information

Post-process the CFD SolutionPost-process the CFD Solution

Page 20: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 20/21

ACUSIM Software Confidential Information

Post-process the FSI SolutionPost-process the FSI Solution

Page 21: AcuSolve Biomed Examples

8/7/2019 AcuSolve Biomed Examples

http://slidepdf.com/reader/full/acusolve-biomed-examples 21/21

Page 21ACUSIM Software Confidential Information

ConclusionsConclusions

n AcuSolve is a powerful general purpose CFD codel

The premier commercial finite element based CFD solver l

n Major focusl Robustness

l Speed

l Accuracy

l Functionality

l Ease of usewith AcuConsole

l

n Ideal for engineering and scientific applications