Addendum Addendum No.: 001T(Final Addendum) Date: 1/6/2021 Project: Lukachukai Community School Project No.: 20-7002.001 From: Dekker/Perich/Sabatini 7601 Jefferson St. NE, Suite 100 Albuquerque, NM 87109 To: All Prospective Bidders and Plan Holders This Addendum forms a part of the Bid Documents and modifies the Bid Documents issued by Dekker/Perich/Sabatini (D/P/S) and Project Manuals dated 12/10/2020 and Drawings dated 12/10/2020. Acknowledge receipt of this Addendum on the Bid Form. Failure to do so may subject the Bidder to disqualification. All other provisions of the Bid Documents shall remain unchanged. This Addendum contains a total of (12)8 ½”x11” pages and (27) 30” x 42” sheets. Bid Package #4 Teacherages 1. GENERAL:
1.1. Submitted Questions and Responses. 1.1.1. Q: Are all of the units supposed to have fire alarm panels or just the ADA units?
A: Yes all units require fire alarm due to the fire protection. 1.1.2. Q: Thermal Insulation specification section 07 2100 – 5, 2.2 Foam Board Insulation
Materials; B. and 3.6 Board Insulation over low slope roof deck ask for poly-iso over roof deck, however plans show all roof locations in bid lot 4 to have batt insulation under roof deck. Which do we follow? A:Exterior wall type legend calls for 1 ½” Rigid insulation over dec, and R-19 Batt insulation tied tight to bottom of deck. A loose layer of R-09 batt insulation is also required to be draped over mechanical ductwork in attic
1.1.3. Metal Roof Panels section 07 4112 – 2; 2.1- B. asks for concealed fastener roof panels were as plan GI000, Partition Type Legend R1 shows Pro-Panel (Corrugated) Roofing Panel. Which type should be provided? If the concealed fastener panels are selected, is a snap lock or mechanical seamed panel preferred? A: Pro-Panel corrugated roof panel per VE.
1.1.4. Metal Roof Panels section 07 4112 – 2; 2.1-B. asks for full range of colors. This could increase material cost up 20% when including metallic colors. Would manufacturers standard colors be acceptable? A: Full Range of Standard Colors.
1.1.5. Metal Roof Panels section 07 4112 – 2; 2.5-D. Underlayment is to be a synthetic underlayment with no other direction. B3/AE501 shows self adhering polymer-modified bitumen extending 24” up slope beyond inside face of the exterior wall. Is the intention to use both products as separately outlined? A: Follow self adhering bitumen extending 24” up slope as in B3.AE501. This meets NFPA requirements.
1.1.6. Metal Roof Panels section 07 4112 – 2; 2.5-E and Roof Accessories section 07 7200 – 1; 2.4-A ask for snow guard. Is the intent to provide snow guard at all eave locations or just doorways? A: At door ways only is acceptable.
1.1.7. There are CO detectors drawn on the plans next to the thermostat. Are these in the mechanical scope? The heat pumps that are in the mechanical scope are all electric. If they are required in the mechanical scope, please provide a make and model of them. A: The CO sensor have been changed to CO2 sensor and is a part of the Mechanical scope.
1.1.8. In the specification book under division 23, they are asking for controls contractor and building automation systems. Is this actually needed on the houses? A: No, automation systems can be eliminated from the specifications.
1.1.9. Page es101 shows outside disconnect , one per building but e101, e-201 show two per building? A: One location on electrical plans are shown as one possible location the other is the possible alternate location per conduits entering from the utility transformer as noted in the keynotes.
1.1.10. Spec indicate romex is acceptable , but sheet show 220 circuits in conduit, is it all romex or all conduit? A: Romex is acceptable at the teacherages only
1.1.11. What is entailed with a radon suction pit? There is no detail for this . Is the 6" just ran from below the slab and thru the roof? PP. p101, 103 A: The Radon mitigation system will have a 6” diameter vertical vent pipe and 4” gravel base. GFCI to be located in attic space for future active system.
2. SPECIFICATIONS:
2.1. SECTION 08 1416 – FLUSH WOOD DOORS 2.1.1. Replace this section in its entirety
2.2. SECTION 08 1613 – FIBERGLASS DOORS 2.2.1. Add this section in its entirety
3. DRAWINGS:
3.1. GI101 - CODE ANALYSIS AND LIFE SAFETY PLAN 3.1.1. Revise applicable code data as indicated in table. 3.1.2. Replace this sheet in its entirety
3.2. AE101 - 1BD/1BA DUPLEX - PLANS 3.2.1. Revise floor plan A5 as indicated. 3.2.2. Replace this sheet in its entirety
3.3. AE102 - 2BD/1BA DUPLEX – PLANS 3.3.1. Revise floor plan A5 as indicated. 3.3.2. Replace this sheet in its entirety.
3.4. AE103 - 3BD/2BA SINGLE-FAMILY – PLANS 3.4.1. Revise floor plan A5 as indicated. 3.4.2. Replace this sheet in its entirety.
3.5. AE104 - TYPE 'A' UNITS - FLOOR PLANS 3.5.1. Revise floor plans A5, A1, and C5 as indicated. 3.5.2. Replace this sheet in its entirety.
3.6. AE201 - 1BD/1BA DUPLEX - EXTERIOR ELEVATIONS 3.6.1. Revise elevations B5, B2, and D5 as indicated. 3.6.2. Replace this sheet in its entirety.
3.7. AE203 - 3BD/2BA SINGLE-FAMILY - EXTERIOR ELEVATIONS 3.7.1. Revise elevations B5, B2, and D5 as indicated. 3.7.2. Replace this sheet in its entirety.
3.8. AE221 - INTERIOR ELEVATIONS 3.8.1. Revise elevations B3, C2, and E3 as indicated. 3.8.2. Replace this sheet in its entirety.
3.9. AE222 - INTERIOR ELEVATIONS - TYPE 'A' UNITS 3.9.1. Revise elevations B1 and C1 as indicated. 3.9.2. Replace this sheet in its entirety.
3.10. AE301 - 1BD/1BA DUPLEX - BUILDING / WALL SECTIONS 3.10.1. Revise wall sections D5 and D3 as indicated. 3.10.2. Replace this sheet in its entirety.
3.11. AE361 - CASEWORK SECTIONS 3.11.1. Revise sections A1-A5 and C4 as indicated. 3.11.2. Replace this sheet in its entirety.
3.12. AE501 - ENLARGED DETAILS 3.12.1. Remove details A1 and A2. 3.12.2. Revise details A3 and A4 as indicated. 3.12.3. Replace this sheet in its entirety
3.13. AE561 - DOOR / WINDOW / FRAME TYPES, DETAILS AND SCHEDULES 3.13.1. Revise window details C1 and C2, and door details D1 and D2 as indicated. 3.13.2. Revise window types at B1 as indicated. 3.13.3. Replace this sheet in its entirety.
3.14. M-001 – MECHANICAL LEGEND 3.14.1. REVISE CO2 sensor symbol. 3.14.2. REPLACE this sheet in its entirety.
3.15. MH101 – HVAC PLAN – 1BD/1BA DUPLEX 3.15.1. REVISE dryer vent. 3.15.2. REPLACE this sheet in its entirety.
3.16. MH102 – HVAC PLAN – 2BD/1BA DUPLEX 3.16.1. REVISE condenser unit location 3.16.2. REPLACE this sheet in its entirety.
3.17. MH103 – HVAC PLAN – 3BD/2BA SINGLE-FAMILY 3.17.1. REVISE pipe to offset inside closet 3.17.2. REVISE duct offset below roof. 3.17.3. REVISE HP-5 location. 3.17.4. REPLACE this sheet in its entirety.
3.18. PL101 – WASTE & VENT PLAN – 1BD/1BA DUPLEX 3.18.1. REVISE waste and vent plans per architectural background changes. 3.18.2. REPLACE this sheet in its entirety.
3.19. PL102 – WASTE & VENT PLAN – 2BD/1BA DUPLEX 3.19.1. REVISE waste and vent plans per architectural background changes. 3.19.2. REPLACE this sheet in its entirety.
3.20. PL103 – WASTE & VENT PLAN – 3BD/2BA DUPLEX 3.20.1. REVISE waste and vent plans per architectural background changes. 3.20.2. REPLACE this sheet in its entirety.
3.21. PP101 – PRESSURE PIPING PLAN – 1BD/1BA DUPLEX 3.21.1. REVISE pressure piping plans per architectural background changes. 3.21.2. REPLACE this sheet in its entirety.
3.22. PP101 – WASTE & VENT PLAN – 2BD/1BA DUPLEX 3.22.1. REVISE pressure piping plans per architectural background changes. 3.22.2. REPLACE this sheet in its entirety.
3.23. PP101 – WASTE & VENT PLAN – 3BD/2BA DUPLEX 3.23.1. REVISE pressure piping plans per architectural background changes. 3.23.2. REPLACE this sheet in its entirety.
3.24. E-101 – ELECTRICAL PLANS – 1BD/1BA DUPLEX 3.24.1. REVISE lighting and power plans per architectural background changes. 3.24.2. REPLACE this sheet in its entirety.
3.25. E-102 – ELECTRICAL PLANS – 2BD/1BA DUPLEX
3.25.1. REVISE lighting and power plans per architectural background changes. 3.25.2. REPLACE this sheet in its entirety.
3.26. E-103 – ELECTRICAL PLANS – 3BD/2BA SINGLE-FAMILY 3.26.1. REVISE lighting and power plans per architectural background changes. 3.26.2. REPLACE this sheet in its entirety.
3.27. T-103 – WASTE & VENT PLAN – 1BD/1BA DUPLEX 3.27.1. MOVE data port in each residence to avoid plumbing 3.27.2. REPLACE this sheet in its entirety.
All other provisions of the Contract Documents shall remain unchanged. This addendum is hereby made a part of the Contract Documents to the same extent as those provisions contained in the original documents and all itemized listings thereof. End of Addendum
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FIBERGLASS DOORS08 1613 - 1
SECTION 08 1613 - FIBERGLASS DOORS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Fiberglass doors.
B. Fiberglass door frames-Prehung with Metal Frame.
C. Glazing.
1.2 RELATED REQUIREMENTS
A. Section 08 7100 - Door Hardware.
B. Section 09 9113 - Exterior Painting: Field painting.
1.3 REFERENCE STANDARDS
A. AAMA 1503 - Voluntary Test Method for Thermal Transmittance and CondensationResistance of Windows, Doors and Glazed Wall Sections; 2009.
B. ASTM A653/A653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) orZinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process; 2017.
C. ASTM D635 - Standard Test Method for Rate of Burning and/or Extent and Time of Burningof Plastics in a Horizontal Position; 2014.
D. ASTM E84 - Standard Test Method for Surface Burning Characteristics of Building Materials;2015a.
E. ASTM E283 - Standard Test Method for Determining the Rate of Air Leakage ThroughExterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across theSpecimen; 2004 (Reapproved 2012).
1.4 SUBMITTALS
A. See Section 01 3000 - Administrative Requirements, for submittal procedures.
B. Product Data: Provide manufacturer's standard details, installation instructions, hardware andanchor recommendations.
C. Shop Drawings: Indicate layout and profiles; include assembly methods.
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FIBERGLASS DOORS08 1613 - 2
1. Indicate product components, including hardware reinforcement locations andpreparations, accessories, finish colors, patterns, and textures.
2. Indicate wall conditions, door and frame elevations, sections, materials, gauges, finishes,location of door hardware by dimension, and details of openings; use same referencenumbers indicated on drawings to identify details and openings.
1.5 DELIVERY, STORAGE, AND HANDLING
A. Mark doors with location of installation, door type, color, and weight.
B. Deliver materials in manufacturer’s original, unopened, undamaged containers withidentification labels intact.
C. Store materials in original packaging, under cover, protected from exposure to harmful weatherconditions and from direct contact with water.
1. Store at temperature and humidity conditions recommended by manufacturer.
2. Do not use non-vented plastic or canvas shelters.
3. Immediately remove wet wrappers.
D. Store in position recommended by manufacturer, elevated minimum 4 inches above grade, withminimum 1/4 inch space between doors.
PART 2 PRODUCTS
2.1 MANUFACTURERS
2.2 DOOR AND FRAME ASSEMBLIES
A. Door and Frame Assemblies: Factory-fabricated, prepared and machined for hardware.
1. Screw-Holding Capacity: Tested to 890 pounds, minimum.
2. Surface Burning Characteristics: Flame spread index (FSI) of 0 to 25, Class A, andsmoke developed index (SDI) of 450 or less, when tested in accordance with ASTM E84.
3. Flammability: Self-extinguishing when tested in accordance with ASTM D635.
4. Clearance Between Door and Frame: 1/8 inch, maximum.
5. Clearance Between Bottom of Door and Finished Floor: 3/4 inch, maximum; not lessthan 1/4 inch clearance to threshold.
2.3 COMPONENTS
A. Doors: Fiberglass construction with reinforced core.
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FIBERGLASS DOORS08 1613 - 3
1. Thickness: 1-3/4 inch, nominal.
2. Core Material: Manufacturer's standard core material for application indicated.
3. Construction:
4. Face Sheet Texture: Smooth.
5. Door Panel: As indicated on drawings.
6. Subframe and Reinforcements: Manufacturer's standard materials.
7. Waterproof Integrity: Provide factory fabricated edges, cut-outs, and hardwarepreparations of fiberglass reinforced plastic (FRP); provide cut-outs with joints sealedindependently of glazing, louver inserts, or trim.
8. Hardware Preparations: Factory reinforce, machine, and prepare for door hardwareincluding field installed items; provide solid blocking for each item; field cutting, drillingor tapping is not permitted; obtain manufacturer's hardware templates for preparation asnecessary.
B. Door Frames: Provide type in compliance with performance requirements specified for doors.
1. Type: Prehung with Metal Frame.
2. Profiles: As indicated on drawings.
3. Basis of Design: Adjustafit Ready Frames
2.4 PERFORMANCE REQUIREMENTS
A. Provide door assemblies that have been designed and fabricated in compliance with specifiedperformance requirements.
B. Air Leakage: Maximum of 0.1 cfm per square foot at 6.27 psf differential pressure, whentested in accordance with ASTM E283.
C. Thermal Transmittance, Exterior Doors: AAMA 1503, U-value of 0.35, maximum, measuredon exterior door in size required for this project.
2.5 FINISHES
A. Painted: Two-part aliphatic polyurethane, low VOC industrial coating.
1. Thickness: Minimum 5 mils, 0.005 inch wet thickness.
2. Color: As selected by Architect from manufacturer's custom line of colors.
2.6 ACCESSORIES
A. Glazing:
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FIBERGLASS DOORS08 1613 - 4
1. Fully tempered float glass, 1/4 inch thick, clear.
B. Door Hardware: See Section 08 7100.
C. Eye Viewer: At unit entry doors as indicated on drawings
END OF SECTION
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FLUSH WOOD DOORS08 1416 - 1
SECTION 08 1416 - FLUSH WOOD DOORS
PART 1 GENERAL
1.1 SECTION INCLUDES
A. Solid-core, wood doors; flush configuration; Prehung with Frame.
1.2 RELATED REQUIREMENTS
A. Section 06 2000 - Finish Carpentry: Wood door frames.
B. Section 08 1113 - Hollow Metal Doors and Frames.
C. Section 08 7100 - Door Hardware.
D. Section 09 9123 - Interior Painting: Field finishing of doors.
1.3 SUBMITTALS
A. See Section 01 3000 - Administrative Requirements, for submittal procedures.
B. Product Data: Indicate door core materials and construction; veneer species, type andcharacteristics.
C. Shop Drawings: Show doors and frames, elevations, sizes, types, swings, undercuts, beveling,blocking for hardware, factory machining, factory finishing, cutouts for glazing and otherdetails.
D. Samples: Submit two samples of door veneer, 3 by 6 inch in size illustrating wood grain, staincolor, and sheen for each finish scheduled or selected.
E. Manufacturer's Installation Instructions: Indicate special installation instructions.
F. Specimen warranty.
G. Warranty, executed in Owner's name.
1.4 QUALITY ASSURANCE
A. Manufacturer Qualifications: Company specializing in manufacturing the products specified inthis section, with not less than five years of documented experience.
B. Source Limitations: Obtain flush wood pre hung doors through one source from a singlemanufacturer.
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FLUSH WOOD DOORS08 1416 - 2
1.5 DELIVERY, STORAGE, AND HANDLING
A. Package, deliver and store doors in accordance with specified quality standard.
B. Accept doors on site in manufacturer's packaging. Inspect for damage.
C. Protect doors with resilient packaging sealed with heat shrunk plastic. Do not store in damp orwet areas; or in areas where sunlight might bleach veneer. Seal top and bottom edges withtinted sealer if stored more than one week. Break seal on site to permit ventilation.
1.6 WARRANTY
A. See Section 01 7800 - Closeout Submittals, for additional warranty requirements.
B. Include coverage for delamination of veneer, warping beyond specified installation tolerances,defective materials, and telegraphing core construction.
PART 2 PRODUCTS
2.1 DOORS
A. Doors: Refer to drawings for locations and additional requirements.
1. Wood Veneer Faced Doors: 5-ply unless otherwise indicated.
B. Interior Doors: Flush solid core construction.
1. Thickness: 1-3/4 inches, unless otherwise indicated.
2. Facing: Wood veneer with factory transparent finish as indicated on drawings.
3. Prehung hinges with wood frame
2.2 DOOR AND PANEL CORES
A. Non-Rated Solid Core and 20 Minute Rated Doors: Type particleboard core (PC), plies andfaces as indicated.
B. Hollow Core Doors: Type - Standard (FSHC); plies and faces as indicated above.
2.3 DOOR CONSTRUCTION
A. Fabricate doors in accordance with door quality standard specified.
B. Cores Constructed with stiles and rails:
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FLUSH WOOD DOORS08 1416 - 3
C. Factory machine doors for hardware other than surface-mounted hardware, in accordance withhardware requirements and dimensions.
D. Factory fit doors for frame opening dimensions identified on shop drawings, with edgeclearances in accordance with specified quality standard.
1. Exception: Doors to be field finished.
E. Provide edge clearances in accordance with the quality standard specified.
F. Shop priming: Doors for Opaque Finish: Shop prime doors with one coat of wood primerspecified in Division 09 Section "Interior Painting". Seal all four edges, edges of cutouts, andmortises with primer.
2.4 ACCESSORIES
A. Wood Door Frames: As specified in Section 06 2000.
B. Hollow Metal Door Frames: As specified in Section 08 1113.
C. Door Hardware: As specified in Section 08 7100.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify existing conditions before starting work.
B. Verify that opening sizes and tolerances are acceptable.
C. Do not install doors in frame openings that are not plumb or are out-of-tolerance for size oralignment.
3.2 INSTALLATION
A. Install doors in accordance with manufacturer's instructions and specified quality standard.
B. Factory-Finished Doors: Do not field cut or trim; if fit or clearance is not correct, replace door.
C. Field-Finished Doors: Trimming to fit is acceptable.
1. Adjust width of non-rated doors by cutting equally on both jamb edges.
2. Trim maximum of 3/4 inch off bottom edges.
D. Use machine tools to cut or drill for hardware.
TeacheragesLukachukai Community Schools
Lukachukai , AZ
FLUSH WOOD DOORS08 1416 - 4
E. Coordinate installation of doors with installation of frames and hardware.
3.3 TOLERANCES
A. Comply with specified quality standard for fit and clearance tolerances.
B. Comply with specified quality standard for telegraphing, warp, and squareness.
3.4 ADJUSTING
A. Adjust doors for smooth and balanced door movement.
B. Adjust closers for full closure.
END OF SECTION
EWH EWH
FD FDEXP
EWH
EXP
EWH
EXPFD
EWH
LIVING/DINING
100
LAUNDRY
104
HALL
105
BATH
107
BEDROOM
108
CLOSET
109
BATH
127
BEDROOM
128
LIVING/DINING
120
KITCHEN
121
LAUNDRY
124
CLOSET
129
COVERED PORCH
COVERED PATIO
COVERED PORCH
COVERED PATIO
KITCHEN
101
AREA CALCULATIONSHEATED AREA: 1,530 SF
COVERED PORCH: 140 SFCOVERED PATIO: 140 SF
TOTAL UN-HEATED: 280 SF
TOTAL BUILDING AREA: 1,810 SF
HALL
125
MECH.
123
MECH.
103
COAT
106
COAT
126
STORAGE
130
STORAGE
110
GENERAL SHEET NOTES
A. SMOKE DETECTORS TO BE INSTALLED PER NFPA 70 AND MANUFACTURER'S INSTALLATION INSTRUCTIONS.
B. SMOKE DETECTORS ARE TO BE HARD-WIRED WITH BATTERY BACKUPS AND INTERCONNECTED.C. CARBON MONOXIDE ALARMS TO BE INSTALLED PER NFPA 70 AND MANUFACTURER'S INSTALLATION
INSTRUCTIONS.
SHEET LEGEND
ROOM NAMEROOM NUMBERAREA OF ROOM/SF PER OCCUPANT (NFPA 5000 2018)OCCUPANT LOAD OF ROOM
APPLICABLE CODES
2018 NFPA 101 Life Safety Code2018 NFPA 5000 Building Construction and Safety Code2007 ASHRAE 90.2 Energy Efficient Design of Low-Rise Residential Buildings2017 NFPA 70 National Electric Code (NEC)2018 NFPA 54 National Fuel Gas Code2018 Uniform Plumbing Code2018 Uniform Mechanical Code11/01/2005 Educational Space Criteria Handbook2015 IRC, R301, Ch. 4 and 8 (structural design)Fair Housing Act Design Manual (Revised 1998)
OCCUPANCY GROUP (NFPA 5000 CHAPTER 6.1.8 2018 ed): ONE- AND TWO-FAMILY DWELLING
CONSTRUCTION CLASSIFICATION (NFPA 220): V(000)
• HAZARD CLASSIFICATION: ORDINARY (NFPA 24.1.5)• BUILDINGS ARE EQUIPPED WITH AUTOMATIC SPRINKLER SYSTEM AS REQUIRED FOR ONE- AND
TWO-FAMILY DWELLINGS (NFPA 22.3.5.1)• BUILDINGS ARE EQUIPPED WITH SMOKE DETECTORS AS REQUIRED FOR ONE- AND TWO-FAMILY
DWELLINGS (NFPA 22.3.4.1.1)• BUILDINGS ARE EQUIPPED WITH CARBON MONOXIDE ALARMS (HARD-WIRED WITH BATTERY
BACK-UP) AS REQUIRED FOR ONE- AND TWO-FAMILY DWELLINGS (NFPA 22.3.4.2.1)
150 SF/ 50 SF
Name
3 OCC
101
OCCUPANCY CLASSIFICATION
TYPE OF CONSTRUCTION
FIRE PROTECTION SYSTEMS
APACHE COUNTY, AZCLIMATE ZONE: 3A,B
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT REQUIRED PROVIDED
ROOF R-22 CAVITY R-38WALLS R-15+7.5 ci R19+7.5 ciDOORS U-0.39 U-0.35WINDOWS U-0.47; SHGC 0.40 U-0.35; SHGC 0.40SKYLIGHTS U-0.90; SHGC 0.40 U-0.60; SHGC 0.40
PROVIDED ENVELOPE VALUES ARE HIGHER THAN THE REQUIRED VALUES DUE TO LEED REQUIREMENTS
ENERGY CONSERVATION
FIRE EXTINGUISHER BRACKETFEB
1 HOUR RATED PARTITION, REFER TO PARTITION TYPES
COVERED PORCH
COVERED PATIO
COVERED PORCH
COVERED PATIO
MECH.
204
HALL
208
BATH
209
BATH
229
CLOSET
227
CLOSET
207
MECH.
224
HALL
228
CLOSET
231CLOSET
211
KITCHEN
201
LIVING/DINING
200
BEDROOM
206
BEDROOM
226MUD/LAUNDRY
223
MUD/LAUNDRY
203
BEDROOM
210BEDROOM
230
LIVING/DINING
220
KITCHEN
221
COAT
205
COAT
225
AREA CALCULATIONSHEATED AREA: 2,400 SF
COVERED PORCH: 140 SFCOVERED PATIO: 140 SF
TOTAL UN-HEATED: 280 SF
TOTAL BUILDING AREA: 2,680 SF
STORAGE
232
STORAGE
212
COVERED PORCH
COVERED PATIO
MECH.
307
COAT
308
BATH
303
BATH
312
CLOSET
309
CLOSET
314
BEDROOM
302
BEDROOM
313
BEDROOM
310
LIVING/DINING
300
KITCHEN
304
MUD/LAUNDRY
306
AREA CALCULATIONSHEATED AREA: 1,536 SF
COVERED PORCH: 70 SFCOVERED PATIO: 70 SF
TOTAL UN-HEATED: 140 SF
TOTAL BUILDING AREA: 1,676 SF
STORAGE
315
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
GI101
CODE ANALYSISAND LIFE SAFETYPLANS
RW/JM
20-7002.005
AW/BJ
3/16" = 1'-0"A5 1BD/1BA DUPLEX - LIFE SAFETY PLAN
3/16" = 1'-0"B1 2BD/1BA DUPLEX - LIFE SAFETY PLAN
3/16" = 1'-0"C5 3BD/2BA SINGLE-FAMILY - LIFE SAFETY PLAN
13 01/06/21 ASI-001T
13
EWH
DW
EWH
DW
A5
AE201
B5
AE201
D5
AE201
B2
AE201
A5
AE301
B5
AE301
9'-7 1/2" 7'-4 1/2" 4'-0" 10'-8 1/2"
5'-1
"5
'-6 1
/2"
12
'-1
1/2
"
63'-5"
5'-4
"
14'-8" 2'-8"
23
'-8
"
17'-0" 2'-8"
LIVING/DINING100
HALL105
BATH107
BATH127
LAUNDRY104
BEDROOM108
BEDROOM128
CLO
SE
T
109
CLO
SE
T
129
KITCHEN121
LIVING/DINING120
LAUNDRY124
COVERED PORCH, TYP.
COVERED PATIO, TYP.
31'-8 1/2"
A3
AE301
B2
AE301
100
106
105
108
109
107 127
129128
126
125
120
3'-6"
CLEAR
3'-4"
7'-6
"4
'-4
"
3'-11" 9'-5 1/2" 8'-7 1/2" 9'-8 1/2"
3'-9 1/2" 9'-2" 10'-1" 8'-8"
HALL125
KITCHEN101
8'-8 1/2" 2'-4" 1'-5"
C E E C
C
AAB
C
B
AE221A4
A3
A2
A1
4'-5
"6
'-6
"
RF-1RF-1
RF-1
RF-1
RF-1
RF-1
RF-1RF-1
RF-1
RF-1
51B
D1
51B
51B
51B
51B
MECH.123
COAT126
103
MECH.103
COAT106
STORAGE110 STORAGE
130
130
R&
S
RE
F
RO
S
GD
DW
SH
VS
R&
S
MW
H
WC
TUB
TBTP
LAV
MR
SH
R&
S RE
F
RO
S
GD
DW
SH
VS
R&
S
MW
H
WC
TUB
TB TP
LAV
MR
SH
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
03 3000.04CONCRETE SLAB ON
GRADE
123
P-4
P-3P-4
P-3
110
COVERED PATIO, TYP.
W2 W2
AE501
D4
AE501
D5
AE501
D3
3'-4 1/2"
4'-5
"
RADON MITIGATIONSYSTEM PIPING, VENT
THRU ROOF,TYP.
5'-0
"
AE221 D4
D5
D6
D3
FOR INTERIOR ELEVATIONS AT BATHS 107 & 127, REF. SHEET AE221/D3-D6
51B BF BF
CR CR
TB TB
07 6200.05METAL DOWNSPOUT
07 6200.05METAL DOWNSPOUT
TYP. AT HOUSE CORNERS
07 6200.05METAL DOWNSPOUT
102' - 0"102' - 0"
51B
51B
EQ
EQ
SLO
PE
0.25
"/1'
-0"
F2 F2
LINEN STORAGECABINET
LINEN STORAGECABINET
06 1000.14DIMENSION WOOD
COLUMN; REF. STRUCT.
RF-1RF-1
AE501
C3
AE501
C3
23 0000.05HEAT PUMP UNIT ONCONC. PAD; REF. MECH. 23 0000.05
HEAT PUMP UNIT ONCONC. PAD; REF. MECH.
22 0000.07HOSE BIBB; REF.PLUMBING
22 0000.07HOSE BIBB; REF.PLUMBINGS
LOP
E0.
25"/
1'-0
"
SLO
PE
0.25
"/1'
-0"
SLO
PE
0.25
"/1'
-0"
RADON MITIGATIONPIT; REF. C5/AE501
RADON MITIGATIONPIT; REF. C5/AE501
12
'-8
"
1'-5" 2'-5 1/2" 8'-8 1/2"
6'-3
"4
'-8
"
LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. REFEENCE SITE PLAN FOR LOCATIONS OF ADA-ACCESSIBLE HOUSING UNITS FOR EACH UNIT TYPE.
B. REFERENCE SITE PLAN FOR LOCATIONS OF HOUSING UNITS WITH PROVISIONS FOR THE HEARING IMPAIRED.
C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. PROVIDE BLOCKING AT ALL TOILET AND SHOWER LOCATIONS FOR SECURING GRAB BARS. E. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR EXTERIOR WALL
TYPE DESCRIPTIONS.F. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR WALL
TYPE DESCRIPTIONS.G. AT EXTERIOR STORAGE ROOMS WHERE WALL TYPE 51B IS CALLED OUT, PROVIDE BATT
INSULATION TO MATCH ADJACENT/ADJOINING EXTERIOR WALLS, TYP.H. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE DESCRIPTIONS.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE EXTERIOR
GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF MEP-
RELATED SYMBOLS.L. DISHWASHER SHOWN FOR LOCATION AND REFERENCE ONLY; NOT IN CONTRACT.M. CONTRACTOR TO SUPPLY AND INSTALL RANGE AND REFRIGERATOR ONLY. ALL OTHER
APPLIANCES BY OWNER AND INSTALLED BY CONTRACTOR.N. PROVIDE GAS LINE STUB OUT FOR RANGE AT ALL UNITS, TYP. REFER TO MECHANICAL.O. ALL INTERIOR FINISHES FLAME SPREAD REQUIREMENTS SHALL BE IN COMPLIANCE WITH NFPA
5000 (2018), CHAPTER 10.2. P. PAINT ALL GYP. BOARD CEILINGS IN UNITS P-2, UNLESS NOTED OTHERWISE.Q. PAINT ALL GYP BOARD WALLS IN UNITS P-1, UNLESS NOTED OTHERWISE.R. ALL FINISH TRANSITIONS THAT OCCUR AT DOORWAYS TRANSITION MATERIAL AT CENTERLINE OF
DOOR WHEN CLOSEDS. ALL FLOORING TO RUN CONTINOUSLY UNDER APPLIANCES AND AT OPEN CABINET CONDITIONST. ALL GYP BOARD WALLS TO RECEIVE WB-1, UNLESS NOTED OTHERWISE.U. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND INSTALLED
BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.V. RADON MITIGATION SYSTEM UNDERSLAB ASSEMBLY WITH GRAVEL PITS AND 6"DIA. VERTICAL
VENT PIPING BY CONTRACTOR, OVER 4" GRAVEL BASE. REF. STRUCTURAL FOR SLAB-ON-GRADE DETAILS.
W. COORDINATE RADON PIPING LOCATIONS PRIOR TO PLACING SLAB. PROVIDE GFCI IN ATTIC FOR FUTURE ACTIVE SYSTEM.
X. AT MECHANICAL ROOM, PROVIDE ELEVATED BASE @ T/BASE = 2'-0" A.F.F. FOR WATER HEATER AND FURNACE CONSISTING OF 2x6 FRAMING (AT 16" O.C.) & PLYWOOD DECKING.
Y. FOR MAINTENANCE, PROVIDE ACCESS PANEL TO FLOOR DRAIN/SINK AT MECH. ROOM.
FLOOR MATERIAL; REFER TO FINISH LEGEND
FLOORING MATERIAL TRANSITION, TRANSITION STRIP REQUIRED, REF. AF621
FLOORING PATTERN TRANSITION, NO TRANSITION STRIP REQUIRED
SPECIALTY WALL FINISH, REFER TO FINISH LEGEND
FLOORING DIRECTION
5'-0" DIAMETER TURNING RADIUS
ACCESSIBILITY CLEAR SPACE AS INDICATED
XX-X
XX-X
FIXTURE LEGEND
APPLIANCE LEGEND
GENERAL LEGEND
BF BATH FAUCETGD GARBAGE DISPOSAL, SWITCH
CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS
FD FLOOR DRAINLAV LAVATORYADA LAV ADA LAVATORY, COORDINATE
PLUMBING WITH APRON CASEWORKRS ROLL-IN SHOWER WITH TILE SURROUND
ADA DW ADA DISHWASHERDW DISHWASHERADA REF ADA REFRIGERATORREF REFRIGERATORADA RO ADA ELECTRIC RANGE/ OVENRO RANGE/ OVENW WASHERD DRYERMIC MICROWAVE (ADA) ON COUNTERTOPRH ADA EXHAUST HOOD, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS WH WATER HEATERF FURNACE
CR SHOWER CURTAIN RODGBXX GRAB BAR PER ANSI A117.1 XX INDICATES WIDTHMR MIRROR, FULL WIDTH OF VANITY COUNTERTOP R&S ROD & SHELF - WIRE CLOSET SHELVINGRH ROBE HOOKSHVS SHELF - WIRE CLOSET SHELVINGTB TOWEL BARTP TOILET PAPER DISPENSERWS WORK SURFACE, 30" WIDE MINIMUM CLEARANCE
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52AINTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
TUB TUB & SHOWER, VERIFY DIMENSION PER UNIT
S SINKADA S ADA SINK, COORDINATE PLUMBING
WITH APRON CASEWORKWC WATER CLOSETSH SHOWER HEADSHWR SHOWERSS SHOWER SEAT
NOTE: REFER TO PLUMBING FIXTURE SCHEDULE FOR MANUFACTURER AND MODEL NUMBERS
A5
AE301
B5
AE301
4"
/ 1
'-0
"4
" / 1
'-0
"
4" / 1'-0"
4" / 1'-0" 4" / 1'-0"
4" / 1'-0"
4" / 1'-0"4" / 1'-0"
A3
AE301
B2
AE301
1'-4
"
1'-4
"
METAL DOWNSPOUTSTO MATCH METAL ROOF PANELS,TYP.; (6) TOTAL DOWNSPOUTS
LINE AT OUTSIDE FACE-OF-STUDOF WALL BELOW, TYP.
RIDGE
RIDGE
VALLEY
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
4" / 1'-0" 4" / 1'-0"
3'-0" 20'-8" 18'-9"
3'-0" 16'-8" 26'-9" 16'-8" 3'-0"
20'-8" 3'-0"
5'-0
"2
6'-4
"5
'-0
"
NOTE:REF. MH SHEETS FORVENTING PIPE LOCATIONSAT ROOF
RADON MITIGATION SYSTEMPIPING, TYP.
NOTE: PROVIDE SELF-ADHERING WEATHER BARRIER AT ALL ROOF VALLEYS AND ROOF DECK PENETRATIONS
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE101
1BD/1BA DUPLEX- PLANS
RW/JM
20-7002.005
AW
1/4" = 1'-0"A5 FLOOR PLAN - 1BD/1BA DUPLEX - TYPE B
03 3000.04 CONCRETE SLAB ON GRADE
06 1000.08 DIMENSIONAL CEDAR COLUMN, REF: STRUCT.
06 1000.14 DIMENSION WOOD COLUMN; REF. STRUCT.
07 4646.06 FIBER CEMENT FASCIA BOARD
07 6200.04 METAL GUTTER
07 6200.05 METAL DOWNSPOUT
22 0000.07 HOSE BIBB; REF. PLUMBING
23 0000.05 HEAT PUMP UNIT ON CONC. PAD; REF. MECH.
0' 2' 4' 8'
1/4" = 1'-0"C5 ROOF PLAN - 1BD/1BA DUPLEX0' 2' 4' 8'
13
13
13 01/06/21 ASI-001T
DW
DW
FD FD
EXP
EWH
EXP
EWH
LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. REFEENCE SITE PLAN FOR LOCATIONS OF ADA-ACCESSIBLE HOUSING UNITS FOR EACH UNIT TYPE.
B. REFERENCE SITE PLAN FOR LOCATIONS OF HOUSING UNITS WITH PROVISIONS FOR THE HEARING IMPAIRED.
C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. PROVIDE BLOCKING AT ALL TOILET AND SHOWER LOCATIONS FOR SECURING GRAB BARS. E. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR EXTERIOR WALL
TYPE DESCRIPTIONS.F. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR WALL
TYPE DESCRIPTIONS.G. AT EXTERIOR STORAGE ROOMS WHERE WALL TYPE 51B IS CALLED OUT, PROVIDE BATT
INSULATION TO MATCH ADJACENT/ADJOINING EXTERIOR WALLS, TYP.H. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE DESCRIPTIONS.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE EXTERIOR
GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF MEP-
RELATED SYMBOLS.L. DISHWASHER SHOWN FOR LOCATION AND REFERENCE ONLY; NOT IN CONTRACT.M. CONTRACTOR TO SUPPLY AND INSTALL RANGE AND REFRIGERATOR ONLY. ALL OTHER
APPLIANCES BY OWNER AND INSTALLED BY CONTRACTOR.N. PROVIDE GAS LINE STUB OUT FOR RANGE AT ALL UNITS, TYP. REFER TO MECHANICAL.O. ALL INTERIOR FINISHES FLAME SPREAD REQUIREMENTS SHALL BE IN COMPLIANCE WITH NFPA
5000 (2018), CHAPTER 10.2. P. PAINT ALL GYP. BOARD CEILINGS IN UNITS P-2, UNLESS NOTED OTHERWISE.Q. PAINT ALL GYP BOARD WALLS IN UNITS P-1, UNLESS NOTED OTHERWISE.R. ALL FINISH TRANSITIONS THAT OCCUR AT DOORWAYS TRANSITION MATERIAL AT CENTERLINE OF
DOOR WHEN CLOSEDS. ALL FLOORING TO RUN CONTINOUSLY UNDER APPLIANCES AND AT OPEN CABINET CONDITIONST. ALL GYP BOARD WALLS TO RECEIVE WB-1, UNLESS NOTED OTHERWISE.U. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND INSTALLED
BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.V. RADON MITIGATION SYSTEM UNDERSLAB ASSEMBLY WITH GRAVEL PITS AND 6"DIA. VERTICAL
VENT PIPING BY CONTRACTOR, OVER 4" GRAVEL BASE. REF. STRUCTURAL FOR SLAB-ON-GRADE DETAILS.
W. COORDINATE RADON PIPING LOCATIONS PRIOR TO PLACING SLAB. PROVIDE GFCI IN ATTIC FOR FUTURE ACTIVE SYSTEM.
X. AT MECHANICAL ROOM, PROVIDE ELEVATED BASE @ T/BASE = 2'-0" A.F.F. FOR WATER HEATER AND FURNACE CONSISTING OF 2x6 FRAMING (AT 16" O.C.) & PLYWOOD DECKING.
Y. FOR MAINTENANCE, PROVIDE ACCESS PANEL TO FLOOR DRAIN/SINK AT MECH. ROOM.
FLOOR MATERIAL; REFER TO FINISH LEGEND
FLOORING MATERIAL TRANSITION, TRANSITION STRIP REQUIRED, REF. AF621
FLOORING PATTERN TRANSITION, NO TRANSITION STRIP REQUIRED
SPECIALTY WALL FINISH, REFER TO FINISH LEGEND
FLOORING DIRECTION
5'-0" DIAMETER TURNING RADIUS
ACCESSIBILITY CLEAR SPACE AS INDICATED
XX-X
XX-X
FIXTURE LEGEND
APPLIANCE LEGEND
GENERAL LEGEND
BF BATH FAUCETGD GARBAGE DISPOSAL, SWITCH
CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS
FD FLOOR DRAINLAV LAVATORYADA LAV ADA LAVATORY, COORDINATE
PLUMBING WITH APRON CASEWORKRS ROLL-IN SHOWER WITH TILE SURROUND
ADA DW ADA DISHWASHERDW DISHWASHERADA REF ADA REFRIGERATORREF REFRIGERATORADA RO ADA ELECTRIC RANGE/ OVENRO RANGE/ OVENW WASHERD DRYERMIC MICROWAVE (ADA) ON COUNTERTOPRH ADA EXHAUST HOOD, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS WH WATER HEATERF FURNACE
CR SHOWER CURTAIN RODGBXX GRAB BAR PER ANSI A117.1 XX INDICATES WIDTHMR MIRROR, FULL WIDTH OF VANITY COUNTERTOP R&S ROD & SHELF - WIRE CLOSET SHELVINGRH ROBE HOOKSHVS SHELF - WIRE CLOSET SHELVINGTB TOWEL BARTP TOILET PAPER DISPENSERWS WORK SURFACE, 30" WIDE MINIMUM CLEARANCE
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52AINTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
TUB TUB & SHOWER, VERIFY DIMENSION PER UNIT
S SINKADA S ADA SINK, COORDINATE PLUMBING
WITH APRON CASEWORKWC WATER CLOSETSH SHOWER HEADSHWR SHOWERSS SHOWER SEAT
NOTE: REFER TO PLUMBING FIXTURE SCHEDULE FOR MANUFACTURER AND MODEL NUMBERS
A5
AE202
B5
AE202
D5
AE202
B2
AE202
A5
AE302
B5
AE302
COVERED PORCH, TYP.
COVERED PATIO, TYP.
11'-7 1/2" 8'-9 3/4" 3'-11 1/4" 11'-5 1/2"
71'-8"
14
'-0
"
33
'-0
"
35'-10"
5'-4
"
14'-8" 6'-4"
12
'-1
"
EQ
EQ
LIVING/DINING200
KITCHEN201
MUD/LAUNDRY203
MECH.204
BEDROOM206
HALL208
CLO
SE
T
211
BEDROOM210
BATH209
BATH229
BEDROOM226
MUD/LAUNDRY223
KITCHEN221MECH.
224
HALL228
BEDROOM230
LIVING/DINING220
CLO
SE
T
231
CLO
SE
T
227
CLO
SE
T
207
6'-0 1
/2"
2'-0 1
/2"
A3
AE302
D5
AE302
200
210
209
204
211
220
207B
207A
206
230
229
224
231
227B
227A
2264"
5'-0
"1
1 1
/2"
5'-0
"4
"
2'-9 1
/2"
2'-10
1/2
"
7'-5 1/2" 9'-2" 10'-2 1/2" 9'-0"
223
203
COAT205 COAT
225225205
AE221B4
B3
B2
B1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
RF-1
51B
51B
51B
51B
51BD1
EXTEND TOUNDERSIDE OFSHEATHING
BAAB
A
D D
A
STORAGE212212
STORAGE232
232
W2
R&S
RE
F
RO
S
GD
DW
SH
VS
R&
S
R&
S
MW
H
WC
TUB
TBTP
LAV
MR
SHR&S
RE
F
RO
S
GD
DW
SH
VS
R&
S
R&
S
MW
H
WC
TUB
TBTP
LAV
MR
BF
03 3000.04CONCRETE SLAB ON
GRADE
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
P-3P-4
P-3
P-4
P-3 P-4
3'-10" 5'-4" 3'-0" 3'-0"
LINE OF ROOF ABOVE
W2
4'-6 1
/2"
AE501
D4
AE501
D3
AE501
D5
RADON MITIGATIONSYSTEM PIPING, TYP;VENT THROUGH ROOF.
5'-0
"
20'-2 1/2" 2'-10" 12'-9 1/2"
15'-2"
4'-5 1
/2"
14'-0" TYP.
5'-0
" T
YP
.
FOR INTERIOR ELEVATIONS AT BATHS 209 & 229, REF. SHEET AE221/ D1-D2,E5-E6
CR
SH
CR
51B2
'-10
1/2
"
3'-9"
07 6200.05METAL DOWNSPOUT
07 6200.05METAL DOWNSPOUT
07 6200.05METAL DOWNSPOUT
TYP. AT HOUSE CORNERS
51B
102' - 0" 102' - 0"7
'-3 1
/2"
4'-4
"
F2 F2
LINENSTORAGE
CABINET
LINENSTORAGECABINET
06 1000.14DIMENSION WOOD
COLUMN; REF. STRUCT.
RF-1
RF-1
AE501
C3
AE501
C3
22 0000.07HOSE BIBB; REF.PLUMBING
22 0000.07HOSE BIBB; REF.PLUMBING
23 0000.05HEAT PUMP UNIT ON
CONC. PAD; REF. MECH.
23 0000.05HEAT PUMP UNIT ONCONC. PAD; REF. MECH.
SLO
PE
0.25
"/1'
-0"
SLO
PE
0.25
"/1'
-0"
SLO
PE
0.25
"/1'
-0"
SLO
PE
0.25
"/1'
-0"
RADON MITIGATIONPIT; REF. C5/AE501
11
'-7
1/2
"8
'-10
"1
1'-7
1/2
"
11'-2" 4'-4" 4'-3"
4'-3" 4'-4" 11'-2"
3'-9"
F
7'-1 1/2"7'-1 1/2" 9'-9" 8'-4 1/2"
F
A5
AE302
B5
AE302
4"
/ 1
'-0
"4
" / 1
'-0
"
4" / 1'-0"
4" / 1'-0" 4" / 1'-0"
4" / 1'-0"
4" / 1'-0"4" / 1'-0"
A3
AE302
D5
AE302
1'-4
"
1'-4
"
METAL DOWNSPOUTS TO MATCH METAL ROOF PANELS, TYP.; (6) TOTAL DOWNSPOUTS.
LINE AT OUTSIDE FACE-OF-STUDOF WALL BELOW, TYP.
RIDGE
RIDGE
VALLEY
RADON MITIGATION SYSTEMPIPING, TYP.
07 6200.04METAL GUTTER
07 4646.08FIBER CEMENT SOFFITBOARD
4" / 1'-0"4" / 1'-0"
20'-8" 19'-8 1/256"
35
'-8
"
16'-8" 27'-8" 16'-8"
20'-8"
NOTE:REF. MH SHEETS FORVENTING PIPE LOCATIONSAT ROOF
NOTE: PROVIDE SELF-ADHERING WEATHER BARRIER AT ALL ROOF VALLEYS AND ROOF DECK PENETRATIONS
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE102
2BD/1BA DUPLEX- PLANS
RW/JM
20-7002.005
AW
03 3000.04 CONCRETE SLAB ON GRADE
06 1000.08 DIMENSIONAL CEDAR COLUMN, REF: STRUCT.
06 1000.14 DIMENSION WOOD COLUMN; REF. STRUCT.
07 4646.08 FIBER CEMENT SOFFIT BOARD
07 6200.04 METAL GUTTER
07 6200.05 METAL DOWNSPOUT
22 0000.07 HOSE BIBB; REF. PLUMBING
23 0000.05 HEAT PUMP UNIT ON CONC. PAD; REF. MECH.
0' 2' 4' 8'1/4" = 1'-0"A5 FLOOR PLAN - 2BD/1BA DUPLEX - TYPE B
1/4" = 1'-0"C5 ROOF PLAN - 2BD/1BA DUPLEX0' 2' 4' 8'
13
13 01/06/21 ASI-001T
EXP
DW
FD
EWH
LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. REFEENCE SITE PLAN FOR LOCATIONS OF ADA-ACCESSIBLE HOUSING UNITS FOR EACH UNIT TYPE.
B. REFERENCE SITE PLAN FOR LOCATIONS OF HOUSING UNITS WITH PROVISIONS FOR THE HEARING IMPAIRED.
C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. PROVIDE BLOCKING AT ALL TOILET AND SHOWER LOCATIONS FOR SECURING GRAB BARS. E. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR EXTERIOR WALL
TYPE DESCRIPTIONS.F. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR WALL
TYPE DESCRIPTIONS.G. AT EXTERIOR STORAGE ROOMS WHERE WALL TYPE 51B IS CALLED OUT, PROVIDE BATT
INSULATION TO MATCH ADJACENT/ADJOINING EXTERIOR WALLS, TYP.H. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE DESCRIPTIONS.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE EXTERIOR
GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF MEP-
RELATED SYMBOLS.L. DISHWASHER SHOWN FOR LOCATION AND REFERENCE ONLY; NOT IN CONTRACT.M. CONTRACTOR TO SUPPLY AND INSTALL RANGE AND REFRIGERATOR ONLY. ALL OTHER
APPLIANCES BY OWNER AND INSTALLED BY CONTRACTOR.N. PROVIDE GAS LINE STUB OUT FOR RANGE AT ALL UNITS, TYP. REFER TO MECHANICAL.O. ALL INTERIOR FINISHES FLAME SPREAD REQUIREMENTS SHALL BE IN COMPLIANCE WITH NFPA
5000 (2018), CHAPTER 10.2. P. PAINT ALL GYP. BOARD CEILINGS IN UNITS P-2, UNLESS NOTED OTHERWISE.Q. PAINT ALL GYP BOARD WALLS IN UNITS P-1, UNLESS NOTED OTHERWISE.R. ALL FINISH TRANSITIONS THAT OCCUR AT DOORWAYS TRANSITION MATERIAL AT CENTERLINE OF
DOOR WHEN CLOSEDS. ALL FLOORING TO RUN CONTINOUSLY UNDER APPLIANCES AND AT OPEN CABINET CONDITIONST. ALL GYP BOARD WALLS TO RECEIVE WB-1, UNLESS NOTED OTHERWISE.U. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND INSTALLED
BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.V. RADON MITIGATION SYSTEM UNDERSLAB ASSEMBLY WITH GRAVEL PITS AND 6"DIA. VERTICAL
VENT PIPING BY CONTRACTOR, OVER 4" GRAVEL BASE. REF. STRUCTURAL FOR SLAB-ON-GRADE DETAILS.
W. COORDINATE RADON PIPING LOCATIONS PRIOR TO PLACING SLAB. PROVIDE GFCI IN ATTIC FOR FUTURE ACTIVE SYSTEM.
X. AT MECHANICAL ROOM, PROVIDE ELEVATED BASE @ T/BASE = 2'-0" A.F.F. FOR WATER HEATER AND FURNACE CONSISTING OF 2x6 FRAMING (AT 16" O.C.) & PLYWOOD DECKING.
Y. FOR MAINTENANCE, PROVIDE ACCESS PANEL TO FLOOR DRAIN/SINK AT MECH. ROOM.
FLOOR MATERIAL; REFER TO FINISH LEGEND
FLOORING MATERIAL TRANSITION, TRANSITION STRIP REQUIRED, REF. AF621
FLOORING PATTERN TRANSITION, NO TRANSITION STRIP REQUIRED
SPECIALTY WALL FINISH, REFER TO FINISH LEGEND
FLOORING DIRECTION
5'-0" DIAMETER TURNING RADIUS
ACCESSIBILITY CLEAR SPACE AS INDICATED
XX-X
XX-X
FIXTURE LEGEND
APPLIANCE LEGEND
GENERAL LEGEND
BF BATH FAUCETGD GARBAGE DISPOSAL, SWITCH
CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS
FD FLOOR DRAINLAV LAVATORYADA LAV ADA LAVATORY, COORDINATE
PLUMBING WITH APRON CASEWORKRS ROLL-IN SHOWER WITH TILE SURROUND
ADA DW ADA DISHWASHERDW DISHWASHERADA REF ADA REFRIGERATORREF REFRIGERATORADA RO ADA ELECTRIC RANGE/ OVENRO RANGE/ OVENW WASHERD DRYERMIC MICROWAVE (ADA) ON COUNTERTOPRH ADA EXHAUST HOOD, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS WH WATER HEATERF FURNACE
CR SHOWER CURTAIN RODGBXX GRAB BAR PER ANSI A117.1 XX INDICATES WIDTHMR MIRROR, FULL WIDTH OF VANITY COUNTERTOP R&S ROD & SHELF - WIRE CLOSET SHELVINGRH ROBE HOOKSHVS SHELF - WIRE CLOSET SHELVINGTB TOWEL BARTP TOILET PAPER DISPENSERWS WORK SURFACE, 30" WIDE MINIMUM CLEARANCE
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52AINTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
TUB TUB & SHOWER, VERIFY DIMENSION PER UNIT
S SINKADA S ADA SINK, COORDINATE PLUMBING
WITH APRON CASEWORKWC WATER CLOSETSH SHOWER HEADSHWR SHOWERSS SHOWER SEAT
NOTE: REFER TO PLUMBING FIXTURE SCHEDULE FOR MANUFACTURER AND MODEL NUMBERS
A5
AE203
B5
AE203
D5
AE203
B2
AE203
A5
AE303A2
AE303
C5
AE303
BATH303
BEDROOM302
LIVING/DINING300
BEDROOM313
CLOSET314
HALL311
BATH312
BEDROOM310
CLO
SE
T
309
MUD/LAUNDRY306
MECH.307
COAT308
KITCHEN304
6'-3
"6
'-6
"8
'-11
"
CO
VE
RE
D P
OR
CH
COVERED PATIO
4'-3"
12
'-1
"8
'-10
"1
2'-1
"
33
'-0
"
5'-6 1/2" 9'-8 1/2" 11'-7 1/2" 8'-7" 2'-10" 12'-10 1/2"
15'-3" 20'-2 1/2" 2'-10" 12'-10 1/2"
51'-2"
9'-2
"1
3'-4
1/2
"
C2
AE303
EQ
EQ
3'-0"
CL
R.
2'-8 1
/2"
5'-6 1/2"
2'-10"
306
313
312307
314
310
309
303
3085
'-5 1
/2"
2'-3
"
5'-6"
2'-11
1/2
"
11'-2" 4'-4" 4'-3" 4'-4 1/2"
7'-3 1
/2"
4'-4
"
6'-4 1
/2"
3'-8
"
6'-10" 19'-10"
AE221C4
C3
C2
C1
RF-1
RF-1
RF-1RF-1
RF-1
RF-1
RF-1
RF-1
51'-2"
10
'-0
"2
3'-0
"
EQ
EQ
AB
A
E
D
C
C
E
D
51B
51B
14'-8"
5'-4
"
5'-4"
10
'-4
"
51B
CLO
SE
T
301
301
2'-6"
EQ
EQ
5'-0
"7
'-11
"
302
52A
C
300
STORAGE315
W2
315
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
R&S
SH
VS
TUB
RE
F
RO
S
GD
DW
WC
TBTP
LAV
MR
SH
VS
R&
S
R&
SR
&S
SH
MW
H
WC
TUB
TBTP
LAV
MR
SH
LAV
MR
P-3P-4
P-3
P-4
4'-4
"
5'-0
"
4'-0"
03 3000.04CONCRETE SLAB ONGRADE
2'-8"
LINE OF ROOF ABOVE
TYP.
1'-6"
AE501
D3
AE501
D4
AE501
D5
AE501
D5
RADON MITIGATIONSYSTEM PIPING, TYP.;VENT THROUGH ROOF
5'-3
"1
'-0
"
06 1000.14DIMENSION WOODCOLUMN; REF. STRUCT.
51B
FOR INTERIOR ELEVATIONS AT BATH 312, REF. SHEET AE221/D1-D2,E5-E6
FOR INTERIOR ELEVATIONS AT BATH 303, REF. SHEET AE221/E1-E4
AE221
E1
E3
E2E4
BF
CR
CR
BF
51B
2'-6"
2'-7
"
TB
07 6200.05METAL DOWNSPOUT
TYP. AT HOUSE CORNERS
102' - 0"
4'-4
"7
'-3 1
/2"
SLO
PE
.25"
/1'-0
"
SLOPE.25"/1'-0"
F2
LINEN STORAGECABINET
RF-1
AE501
C3
23 0000.05HEAT PUMP UNIT ONCONC. PAD; REF. MECH.
22 0000.07HOSE BIBB; REF.PLUMBING
RADON MITIGATIONPIT; REF. C5/AE501
3'-9"
24'-6" 7'-7 1/2" 6'-8 1/2"
F
ALIGN
A5
AE303A2
AE303
C5
AE303
4"
/ 1
'-0
"
4"
/ 1
'-0
"
4" / 1'-0"
C2
AE303
1'-4
"
1'-4
"
METAL DOWNSPOUTS TO MATCH METAL ROOF PANELS, TYP.; (4) DOWNSPOUTS TOTAL
LINE AT OUTSIDE FACE-OF-STUDOF WALL BELOW, TYP.
RIDGE
RIDGE
VALLEY
RIDGE
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
4"
/ 1
'-0
"
18'-0" 20'-7" 15'-3"
10
'-0
"2
5'-8
"5
'-0
"
NOTE:REF. MH SHEETS FORVENTING PIPE LOCATIONSAT ROOF
4"
/ 1
'-0
"
4" / 1'-0"
RADON MITIGATION SYSTEMPIPING, TYP.
NOTE: PROVIDE SELF-ADHERING WEATHER BARRIER AT ALL ROOF VALLEYS AND ROOF DECK PENETRATIONS
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE103
3BD/2BASINGLE-FAMILY -PLANS
RW/JM
20-7002.005
AW
03 3000.04 CONCRETE SLAB ON GRADE
06 1000.08 DIMENSIONAL CEDAR COLUMN, REF: STRUCT.
06 1000.14 DIMENSION WOOD COLUMN; REF. STRUCT.
07 4646.06 FIBER CEMENT FASCIA BOARD
07 6200.04 METAL GUTTER
07 6200.05 METAL DOWNSPOUT
22 0000.07 HOSE BIBB; REF. PLUMBING
23 0000.05 HEAT PUMP UNIT ON CONC. PAD; REF. MECH.
1/4" = 1'-0"A5 FLOOR PLAN - 3BD/2BA SINGLE-FAMILY - TYPE B
1/4" = 1'-0"C5 ROOF PLAN - 3BD/2BA SINGLE-FAMILY0' 2' 4' 8'
0' 2' 4' 8'
13
13
13 01/06/21 ASI-001T
WH
DW
FD
FD
WH
DW
WH
DW
FD
LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. REFEENCE SITE PLAN FOR LOCATIONS OF ADA-ACCESSIBLE HOUSING UNITS FOR EACH UNIT TYPE.
B. REFERENCE SITE PLAN FOR LOCATIONS OF HOUSING UNITS WITH PROVISIONS FOR THE HEARING IMPAIRED.
C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. PROVIDE BLOCKING AT ALL TOILET AND SHOWER LOCATIONS FOR SECURING GRAB BARS. E. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR EXTERIOR WALL
TYPE DESCRIPTIONS.F. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR WALL
TYPE DESCRIPTIONS.G. AT EXTERIOR STORAGE ROOMS WHERE WALL TYPE 51B IS CALLED OUT, PROVIDE BATT
INSULATION TO MATCH ADJACENT/ADJOINING EXTERIOR WALLS, TYP.H. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE DESCRIPTIONS.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE EXTERIOR
GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF MEP-
RELATED SYMBOLS.L. DISHWASHER SHOWN FOR LOCATION AND REFERENCE ONLY; NOT IN CONTRACT.M. CONTRACTOR TO SUPPLY AND INSTALL RANGE AND REFRIGERATOR ONLY. ALL OTHER
APPLIANCES BY OWNER AND INSTALLED BY CONTRACTOR.N. PROVIDE GAS LINE STUB OUT FOR RANGE AT ALL UNITS, TYP. REFER TO MECHANICAL.O. ALL INTERIOR FINISHES FLAME SPREAD REQUIREMENTS SHALL BE IN COMPLIANCE WITH NFPA
5000 (2018), CHAPTER 10.2. P. PAINT ALL GYP. BOARD CEILINGS IN UNITS P-2, UNLESS NOTED OTHERWISE.Q. PAINT ALL GYP BOARD WALLS IN UNITS P-1, UNLESS NOTED OTHERWISE.R. ALL FINISH TRANSITIONS THAT OCCUR AT DOORWAYS TRANSITION MATERIAL AT CENTERLINE OF
DOOR WHEN CLOSEDS. ALL FLOORING TO RUN CONTINOUSLY UNDER APPLIANCES AND AT OPEN CABINET CONDITIONST. ALL GYP BOARD WALLS TO RECEIVE WB-1, UNLESS NOTED OTHERWISE.U. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND INSTALLED
BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.V. RADON MITIGATION SYSTEM UNDERSLAB ASSEMBLY WITH GRAVEL PITS AND 6"DIA. VERTICAL
VENT PIPING BY CONTRACTOR, OVER 4" GRAVEL BASE. REF. STRUCTURAL FOR SLAB-ON-GRADE DETAILS.
W. COORDINATE RADON PIPING LOCATIONS PRIOR TO PLACING SLAB. PROVIDE GFCI IN ATTIC FOR FUTURE ACTIVE SYSTEM.
X. AT MECHANICAL ROOM, PROVIDE ELEVATED BASE @ T/BASE = 2'-0" A.F.F. FOR WATER HEATER AND FURNACE CONSISTING OF 2x6 FRAMING (AT 16" O.C.) & PLYWOOD DECKING.
Y. FOR MAINTENANCE, PROVIDE ACCESS PANEL TO FLOOR DRAIN/SINK AT MECH. ROOM.
FLOOR MATERIAL; REFER TO FINISH LEGEND
FLOORING MATERIAL TRANSITION, TRANSITION STRIP REQUIRED, REF. AF621
FLOORING PATTERN TRANSITION, NO TRANSITION STRIP REQUIRED
SPECIALTY WALL FINISH, REFER TO FINISH LEGEND
FLOORING DIRECTION
5'-0" DIAMETER TURNING RADIUS
ACCESSIBILITY CLEAR SPACE AS INDICATED
XX-X
XX-X
FIXTURE LEGEND
APPLIANCE LEGEND
GENERAL LEGEND
BF BATH FAUCETGD GARBAGE DISPOSAL, SWITCH
CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS
FD FLOOR DRAINLAV LAVATORYADA LAV ADA LAVATORY, COORDINATE
PLUMBING WITH APRON CASEWORKRS ROLL-IN SHOWER WITH TILE SURROUND
ADA DW ADA DISHWASHERDW DISHWASHERADA REF ADA REFRIGERATORREF REFRIGERATORADA RO ADA ELECTRIC RANGE/ OVENRO RANGE/ OVENW WASHERD DRYERMIC MICROWAVE (ADA) ON COUNTERTOPRH ADA EXHAUST HOOD, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS WH WATER HEATERF FURNACE
CR SHOWER CURTAIN RODGBXX GRAB BAR PER ANSI A117.1 XX INDICATES WIDTHMR MIRROR, FULL WIDTH OF VANITY COUNTERTOP R&S ROD & SHELF - WIRE CLOSET SHELVINGRH ROBE HOOKSHVS SHELF - WIRE CLOSET SHELVINGTB TOWEL BARTP TOILET PAPER DISPENSERWS WORK SURFACE, 30" WIDE MINIMUM CLEARANCE
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52AINTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
TUB TUB & SHOWER, VERIFY DIMENSION PER UNIT
S SINKADA S ADA SINK, COORDINATE PLUMBING
WITH APRON CASEWORKWC WATER CLOSETSH SHOWER HEADSHWR SHOWERSS SHOWER SEAT
NOTE: REFER TO PLUMBING FIXTURE SCHEDULE FOR MANUFACTURER AND MODEL NUMBERS
AE222C4
C3
C2
C1
BEDROOMA302
LIVING/DININGA300
KITCHENA304
BEDROOMA310
MUD/LAUNDRYA306
MECH.A307
COATA308
HALLA311
CLO
SE
T
A301
BATHA312
BATHA303
BEDROOMA313
CLO
SE
T
A314
CLO
SE
T
A309
STORAGEA315
RF-1
RF-1
RF-1RF-1
RF-1
RF-1
RF-1
RF-1
R&S
SH
VS
TUB
AD
AR
EF
AD
AR
O
AD
A S GD
AD
AD
W
WC
TBTP
LAV
MR
SH
VS
R&
S
R&
SR
&S
SH
RH
WC
TS
TB
TP
ADALAV
MR
SH
ADALAV
MR
P-5P-4
P-5
P-4
A315
A306
A309
A308
A310
A313
A312
A301
A303
A302
A300
A314
C
C
E
E
D
C
B
D1
A1
A1
E
5'-7 1/2" 9'-7 1/2" 2'-8" 4'-0" 4'-11 1/2" 8'-7" 2'-10"
51'-2"
6'-4 1
/2"
3'-8
"
5'-3
"1
'-0
"
10
'-0
"
4'-3"
15'-3" 20'-2 1/2" 2'-10"
5'-0
"
4'-5 1
/2"
14'-0"
5'-0
"
CO
VE
RE
D P
OR
CH
COVERED PATIO
AE501
D3
AE501
D5
AE501
D5
RADON MITIGATIONSYSTEM PIPING, TYP.;
VENT THROUGH ROOF
AE501
D46'-10" 19'-10"
6'-3
"6
'-6
"8
'-11
"
12
'-1
"8
'-10
"1
2'-1
"
EQ
EQ
EQ
EQ
5'-9
"2
'-3
"
11'-2" 4'-4" 4'-3"
13
'-10
"9
'-2
"
10
'-0
"2
3'-0
"
33
'-0
"
52A
51B
51B
51B
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
07 6200.05METAL DOWNSPOUT
03 3000.04CONCRETE SLAB ONGRADE
LINE OF ROOF ABOVE
06 1000.14DIMENSION WOODCOLUMN; REF. STRUCT.
52A
2'-1"
2'-4
"3
'-9 1
/2"
5'-4" 5'-6 1/2"
EQ
EQ
W2
MIC
AE222
E1
E3
E2E4
FOR INTERIOR ELEVATIONS AT BATH 312, REF. SHEET AE221/D1-D2,E5-E6
FOR INTERIOR ELEVATIONS AT BATH 303, REF. SHEET AE222/E1-E4
51B
51B
51B
3'-9"
2'-11
1/2
"
2'-7
"
2'-6"
2'-6"
A307
102' - 0"
SLO
PE
SLOPE 7'-3 1
/2"
4'-4
"4
'-4
"7
'-3 1
/2"
F2
7'-10
"5
'-1
"
ALIGN
F
8'-7 1/2" 15'-11 1/2" 7'-6 1/2" 6'-8 1/2"
WO
RK
SU
RF
AC
E
33"
RF-1
RF-1
RF-1
RF-1
RF-1
R&
SAD
AR
EF
AD
AR
O
ADA S
GD
AD
AD
W
SH
VS
R&
S
MIC
WC
TS
TBTP
ADA LAV
MR
SH
TP
SH
P-4
P-4
RADON MITIGATIONSYSTEM PIPING, TYP.;VENT THROUGH ROOF
LIVING/DININGA100
BEDROOMA108
BATHA107
KITCHENA101
MECH.A103
CLO
SE
T
A109
STORAGEA110
A103
A106
A104
A107
A108
A109
C
C E
B
EXTEND TOUNDERSIDEOF DECK
D1
51B
51B
51B
A1
COVERED PORCH, TYP.
COVERED PATIO, TYP.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
03 3000.04CONCRETE SLAB ON
GRADE
07 6200.05METAL DOWNSPOUT
LINE OF ROOF ABOVE
3'-11" 9'-5 1/2" 8'-7 1/2"
9'-2" 7'-6 1/2" 4'-0" 11'-0"
31'-8 1/2"
3'-4 1/2"
5'-0
"
12
'-8
"
23
'-8
"
14'-0" TYP.
5'-0
" T
YP
.
3'-9 1/2" 9'-2" 10'-1"
16'-6 1/2" 2'-10"
5'-6 1
/2"
5'-4 1
/2"
3'-6"
CLEAR
3'-4"
8'-8 1/2" 2'-3 1/2" 1'-5" 3'-8" 4'-2"
W2
4'-5
"
A110
A100
EQ
EQ
7'-6
"4
'-4
"
52A
3'-1
"
AE222A4
A1
A2
A3
RH
FOR INTERIOR ELEVATIONS AT BATHS 107A, REF. SHEET AE221/D3-D6
51BTB
52A102' - 0"
SLO
PE
SLO
PE
F25'-2
"
COATA104
HALLA105LAUNDRY
A104
WO
RK
SU
RF
AC
E
3'-0
"
COVERED PORCH, TYP.
COVERED PATIO, TYP.
RF-1
RF-1
RF-1
RF-1
P-5
P-4
P-5
RADON MITIGATIONSYSTEM PIPING, TYP.;VENT THROUGH ROOF
R&S
AD
AR
EF
AD
AR
O
ADA S
GD
AD
AD
W
SH
VS
R&
S
R&
S
MIC
WC
TS
TB
TPADA LAV
MR
SH
R&
S
LIVING/DININGA200
KITCHEN201A
MUD/LAUNDRYA203
BEDROOMA206
BATHA209
HALLA208
MECH.A204
COATA205
BEDROOMA210
CLO
SE
T
A211
CLO
SE
T
A207
STORAGEA212
C
A
B
EXTEND TOUNDERSIDE OFSHEATHING
A1
D1
A207B
A207A
A206
A209
A203
A212
A205
A210
A211
A200
14
'-0
"
33
'-0
"
11'-7 1/2" 8'-9" 4'-0" 11'-5 1/2"
6'-5 1/2"
14'-0"
5'-0
"
5'-0
"
D1
51B
51B
5'-6" 2'-10" 3'-0"
5'-0
"
14'-0"
7'-5 1/2" 9'-2" 10'-2 1/2"
7'-4 1
/2"
4'-4
"
EQ
EQ
8'-4 1
/2"
12
'-0
"
2'-0 1
/2"
6'-0 1
/2"
11'-2" 4'-4" 4'-3"
20'-2 1/2" 2'-10"
35'-10"
07 6200.05METAL DOWNSPOUT
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
LINE OF ROOF ABOVE
52A
4"
5'-0
"1
'-0 1
/2"
5'-0
"4
"
3'-4 1/2"
3'-0 1
/2"
W2
RH AE222
B1
B4 B2
B3
AE222D2
D1
E6
E5
3'-9"
A204
102' - 0"
SLO
PE
SLO
PE
F2
18"
ALIGN
11
'-8
1/2
"
7'-4"
07 9200.02SEALANT
?
09 3000-A
09 3000-D
CONCRETE SLAB AND RECESS BELOW PAN
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
1/2
"
07 9200-A
09 8430.02
21B
21B07 9200.02SEALANT
?
03 3000.141" CHAMFER
09 8430.03
09 3000-A
09 3000-D
07 9200.02SEALANT
09 8430.02
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE104
TYPE 'A' UNITS -FLOOR PLANS
RW/JM
20-7002.005
AW
03 3000.04 CONCRETE SLAB ON GRADE
03 3000.14 1" CHAMFER
06 1000.08 DIMENSIONAL CEDAR COLUMN, REF: STRUCT.
06 1000.14 DIMENSION WOOD COLUMN; REF. STRUCT.
07 2500.02 SELF-ADHERED FLEXIBLE FLASHING
07 6200.05 METAL DOWNSPOUT
07 9200-A
07 9200.02 SEALANT
09 3000-A
09 3000-D
09 8430.02
09 8430.03
1/4" = 1'-0"C5 FLOOR PLAN - 3BD/2BA SINGLE-FAMILY
1/4" = 1'-0"A5 FLOOR PLAN - 1BD/1BA DUPLEX1/4" = 1'-0"A1 FLOOR PLAN - 2BD/1BA DUPLEX
0' 2' 4' 8'0' 2' 4' 8'
0' 2' 4' 8'1 1/2" = 1'-0"C1 DETAIL - ROLL IN SHOWER BASE, TYP.
1 1/2" = 1'-0"D1 DETAIL - SHOWER BASE, TYP.
13
13
13
13 01/06/21 ASI-001T
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
B5
AE301
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
4" / 1'-0"
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
C
130
07 4646.03FIBER CEMENT TRIM
03 3000.04CONCRETE SLAB ONGRADE
113' - 3 1/2"
4" / 1'-0"
111' - 8 1/4"
112' - 4 1/4"
RADON MITIGATIONPIPING, TYP.
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
A5
AE301
A3
AE301
B2
AE301
105
C
E E
C
125
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
07 6200.05METAL DOWNSPOUT
07 4646.03FIBER CEMENT TRIM
03 3000.04CONCRETE SLAB ONGRADE
113' - 3 1/2"
112' - 4 1/4"
RADON MITIGATIONPIPING, TYP.
DRYER VENT LOUVER, TYP.;REF. MECHANICAL
22 0000.07HOSE BIBB; REF.PLUMBING
22 0000.07HOSE BIBB; REF.PLUMBING
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
B5
AE301
C
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
03 3000.04CONCRETE SLAB ONGRADE
4" / 1'-0"
07 6200.05METAL DOWNSPOUT
07 4646.03FIBER CEMENT TRIM
110
113' - 3 1/2"
111' - 8 1/4"
112' - 4 1/4"
4" / 1'-0"
RADON MITIGATIONPIPING, TYP.
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
A5
AE301
A3
AE301
B2
AE301
4" / 1'-0"
4" / 1'-0"
B
120
AAB
100
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
03 3000.04CONCRETE SLAB ONGRADE
07 6200.05METAL DOWNSPOUT
07 4646.03FIBER CEMENT TRIM
111' - 8 1/4"
113' - 3 1/2"
4" / 1'-0"
4" / 1'-0"
22 0000.07HOSE BIBB; REF.PLUMBING
22 0000.07HOSE BIBB; REF.PLUMBING
CEMENT FIBER HORIZONTAL LAP SIDING (6" EXPOSURE)
WOOD_CEDAR
LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTESA. REFER TO SHEET AE001 FOR EXPLANATION OF ENCLOSURE ASSEMBLIES.B. REFER TO SHEET AE002 FOR ENCLOSURE CONTINUITY FOR CONTROL LAYER CONTINUITY
INTENT.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR
EXTERIOR WALL TYPE DESCRIPTIONS.E. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR
WALL TYPE DESCRIPTIONS.F. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE
DESCRIPTIONS.G. AT BUILDING SECTIONS, ROOF TRUSS LOCATIONS SHOWN FOR REFERENCE ONLY.
REFERENCE STRUCTURAL DRAWINGS FOR ACTUAL ROOF TRUSS LOCATIONS.H. AT BUILDING SECTIONS, ROOF TRUSS DIAGONALS SHOWN FOR REFERENCE ONLY.
ACTUAL ROOF TRUSS DIAGONALS TO BE DETERMINED BY MANUFACTURER.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE
EXTERIOR GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF
MEP-RELATED SYMBOLS.L. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND
INSTALLED BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.M. FOR WINDOW TYPES A, A1 & B, VERIFY FIXED WINDOW SIDE PER ELEVATIONS AND PLANS.N. PROVIDE R-5 BLANKET INSULATION OVER FIRE SPRINKLER SYSTEM AND DUCTWORK.O. ALL EXTERIOR DOORS AND OPERABLE WINDOWS TO RECEIVE WEATHERSTRIPPING AND
SEALED.P. INSTALL INSULATION TO BE INSTALLED TO RESNET GRADE 1 STANDARDS.Q. DUCTS, FLUES, SHAFTS, PLUMBING, PIPING, WIRING, EXHAUST FANS, & OTHER
PENETRATIONS TO UNCONDITIONED SPACE SEALED, WITH BLOCKING / FLASHING AS NECESSARY.
ROOFING_METAL PANEL
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52A
INTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE201
1BD/1BA DUPLEX- EXTERIORELEVATIONS
RW/JM
20-7002.005
AW
1/4" = 1'-0"B5 1BD/1BA DUPLEX - RIGHT ELEVATION
1/4" = 1'-0"D5 1BD/1BA DUPLEX - BACK ELEVATION
1/4" = 1'-0"B2 1BD/1BA DUPLEX - LEFT ELEVATION
1/4" = 1'-0"A5 1BD/1BA DUPLEX - FRONT ELEVATION
03 3000.04 CONCRETE SLAB ON GRADE
06 1000.07 DIMENSIONAL CEDAR LINTEL, REF: STRUCT.
06 1000.08 DIMENSIONAL CEDAR COLUMN, REF: STRUCT.
07 4646.03 FIBER CEMENT TRIM
07 4646.06 FIBER CEMENT FASCIA BOARD
07 6200.04 METAL GUTTER
07 6200.05 METAL DOWNSPOUT
22 0000.07 HOSE BIBB; REF. PLUMBING
0' 2' 4' 8'
0' 2' 4' 8' 0' 2' 4' 8'
0' 2' 4' 8'
1313
13
13
13 01/06/21 ASI-001T
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
ROOF LEVEL114' - 10 1/2"
A5
AE303
A2
AE303
C2
AE303
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
A B A
07 6200.05METAL DOWNSPOUT
07 4646.03FIBER CEMENT TRIM
03 3000.04CONCRETE SLAB ONGRADE
113' - 2 1/4"
22 0000.07HOSE BIBB; REF.PLUMBING
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
ROOF LEVEL114' - 10 1/2"
C5
AE303
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
4" / 1'-0"
03 3000.04CONCRETE SLAB ONGRADE
C
E
C
315
07 4646.03FIBER CEMENT TRIM
112' - 4 1/4"
4" / 1'-0"
RADON MITIGATIONPIPING, TYP.
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
ROOF LEVEL114' - 10 1/2"
C5
AE303
300
D
E
4" / 1'-0"
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
06 1000.08DIMENSIONAL CEDARCOLUMN, REF: STRUCT.
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
C07 4646.03FIBER CEMENT TRIM
07 6200.05METAL DOWNSPOUT
07 4646.03FIBER CEMENT TRIM
03 3000.04CONCRETE SLAB ONGRADE
4" / 1'-0"
4" / 1'-0"
112' - 4 1/4"
113' - 2 1/4"
RADON MITIGATIONPIPING, TYP.
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
ROOF LEVEL114' - 10 1/2"
A5
AE303
A2
AE303
C2
AE303
07 6200.04METAL GUTTER
07 4646.06FIBER CEMENT FASCIABOARD
03 3000.04CONCRETE SLAB ON
GRADE
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
306
D
4" / 1'-0"
07 6200.05METAL DOWNSPOUT
07 4646.03FIBER CEMENT TRIM
4" / 1'-0"
113' - 2 1/4"
112' - 4 1/4"
RADON MITIGATIONPIPING, TYP.
DRYER VENT LOUVER, TYP.;REF. MECHANICAL FOR DRYERVENT SIZE & HEIGHT A.F.F.
22 0000.07HOSE BIBB; REF.PLUMBING
F
G
CEMENT FIBER HORIZONTAL LAP SIDING (6" EXPOSURE)
WOOD_CEDAR
LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTESA. REFER TO SHEET AE001 FOR EXPLANATION OF ENCLOSURE ASSEMBLIES.B. REFER TO SHEET AE002 FOR ENCLOSURE CONTINUITY FOR CONTROL LAYER CONTINUITY
INTENT.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR
EXTERIOR WALL TYPE DESCRIPTIONS.E. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR
WALL TYPE DESCRIPTIONS.F. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE
DESCRIPTIONS.G. AT BUILDING SECTIONS, ROOF TRUSS LOCATIONS SHOWN FOR REFERENCE ONLY.
REFERENCE STRUCTURAL DRAWINGS FOR ACTUAL ROOF TRUSS LOCATIONS.H. AT BUILDING SECTIONS, ROOF TRUSS DIAGONALS SHOWN FOR REFERENCE ONLY.
ACTUAL ROOF TRUSS DIAGONALS TO BE DETERMINED BY MANUFACTURER.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE
EXTERIOR GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF
MEP-RELATED SYMBOLS.L. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND
INSTALLED BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.M. FOR WINDOW TYPES A, A1 & B, VERIFY FIXED WINDOW SIDE PER ELEVATIONS AND PLANS.N. PROVIDE R-5 BLANKET INSULATION OVER FIRE SPRINKLER SYSTEM AND DUCTWORK.O. ALL EXTERIOR DOORS AND OPERABLE WINDOWS TO RECEIVE WEATHERSTRIPPING AND
SEALED.P. INSTALL INSULATION TO BE INSTALLED TO RESNET GRADE 1 STANDARDS.Q. DUCTS, FLUES, SHAFTS, PLUMBING, PIPING, WIRING, EXHAUST FANS, & OTHER
PENETRATIONS TO UNCONDITIONED SPACE SEALED, WITH BLOCKING / FLASHING AS NECESSARY.
ROOFING_METAL PANEL
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52A
INTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE203
3BD/2BASINGLE-FAMILY -EXTERIORELEVATIONS
RW/JM
20-7002.005
AW
1/4" = 1'-0"A5 3BD/2BA SINGEL-FAMILY - FRONT ELEVATION
1/4" = 1'-0"B5 3BD/2BA SINGEL-FAMILY - RIGHT ELEVATION1/4" = 1'-0"B2 3BD/2BA SINGEL-FAMILY - LEFT ELEVATION
1/4" = 1'-0"D5 3BD/2BA SINGEL-FAMILY - BACK ELEVATION
03 3000.04 CONCRETE SLAB ON GRADE
06 1000.07 DIMENSIONAL CEDAR LINTEL, REF: STRUCT.
06 1000.08 DIMENSIONAL CEDAR COLUMN, REF: STRUCT.
07 4646.03 FIBER CEMENT TRIM
07 4646.06 FIBER CEMENT FASCIA BOARD
07 6200.04 METAL GUTTER
07 6200.05 METAL DOWNSPOUT
22 0000.07 HOSE BIBB; REF. PLUMBING
0' 2' 4' 8'
0' 2' 4' 8' 0' 2' 4' 8'
0' 2' 4' 8'
13
13
13
13 01/06/21 ASI-001T
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. DIMENSIONS ARE TO FINISHED FACE, UNLESS NOTED OTHERWISE.B. REFER TO GI000 FOR TYPICAL TOILET ACCESSORY MOUNTING HEIGHTS.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. PROVIDE BLOCKING AT ALL TOILET AND SHOWER LOCATIONS FOR SECURING GRAB BARS.E. COORDINATE WALL DEVICE LOCATIONS WITH WALL MOUNTED FURNISHINGS. F. COORDINATE WALL ACCESS PANEL LOCATIONS AS TO NOT OVERLAP CHANGES IN
FINISHES.G. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. H. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING (MEP) LEGENDS FOR DESCRIPTION
OF MEP-RELATED SYMBOLS.I. DISHWASHER SHOWN FOR LOCATION AND REFERENCE ONLY; NOT IN CONTRACT.J. CONTRACTOR TO SUPPLY AND INSTALL RANGE AND REFRIGERATOR ONLY. ALL OTHER
APPLIANCES BY OWNER AND INSTALLED BY CONTRACTOR.K. ALL INTERIOR FINISHES FLAME SPREAD REQUIREMENTS SHALL BE IN COMPLIANCE WITH
NFPA 5000 (2018), CHAPTER 10.2.L. PAINT ALL GYP. BOARD CEILINGS IN UNITS P-3, UNOM. PAINT ALL GYP BOARD WALLS IN UNITS P-1, UNON. ALL FINISH TRANSITIONS THAT OCCUR AT DOORWAYS TRANSITION MATERIAL AT
CENTERLINE OF DOOR WHEN CLOSEDO. ALL FLOORING TO RUN CONTINOUSLY UNDER APPLIANCES AND AT OPEN CABINET
CONDITIONSP. ALL GYP BOARD WALLS TO RECEIVE WB-1, UNOQ. ALL GYP BOARDS IN RESTROOMS TO RECEIVE RB-1, UNOR. WHERE SHOWER ABUTS OR IS ADJACENT TO EXTERIOR WALL, PROVIDE WEATHER
BARRIER BEHIND SHOWER.S. PROVIDE MOISTURE-RESISTANT GYPSUM WALLBOARD OR CEMENT BOARD (WITH
CAULKED JOINTS) BEHIND TUB AND/OR SHOWER ENCLOSURES.T. DRYWALL SEALED TO TOP PLATE AT ALL UNCONDITIONED ATTIC / WALL INTERFACES
USING CAULK, FOAM, DRYWALL ADHESIVE (BUT NOT OTHER CONSTRUCTION ADHESIVES), OR EQUIVALENT MATERIAL.
U. KITCHEN AND BATHROOM SINK TO HAVE REMOVABLE BASE CABINETS. FLOORING TO EXTEND UNDER SINK BASE FOR ADAPTABLE CONDITION. CONFIRM ADA TYPE SINK
FIXTURE LEGEND
APPLIANCE LEGEND
GENERAL LEGEND
NOTE: REFER TO PLUMBING FIXTURE SCHEDULE FOR MANUFACTURER AND MODEL NUMBERSBF BATH FAUCETGD GARBAGE DISPOSAL, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITSFD FLOOR DRAINLAV LAVATORYRS ROLL-IN SHOWER WITH TILE SURROUNDTUB TUB & SHOWER, VERIFY DIMENSION PER UNITS SINKWC WATER CLOSETSH SHOWER HEADSHWR SHOWERSS SHOWER SEAT
ADA DW ADA DISHWASHER (OWNER PROVIDED, NIC)DW DISHWASHER (OWNER PROVIDED, NIC)ADA REF ADA REFRIGERATORREF REFRIGERATORADA RO ADA ELECTRIC RANGE/ OVENRO RANGE/ OVENW WASHER (OWNER PROVIDED, NIC)D DRYER (OWNER PROVIDED, NIC)MIC MICROWAVE (ADA) ON COUNTERTOP (OWNER PROVIDED, NIC)RH ADA EXHAUST HOOD, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS WH WATER HEATERF FURNACEMWH MICROWAVE with HOOD (OWNER PROVIDED, NIC)
CR SHOWER CURTAIN RODGBXX GRAB BAR PER ANSI A117.1 XX INDICATES WIDTHMR MIRROR, FULL WIDTH OF VANITY COUNTERTOP R&S ROD & SHELF - WIRE CLOSET SHELVINGRH ROBE HOOKSHVS SHELF - WIRE CLOSET SHELVINGTB TOWEL BARTP TOILET PAPER DISPENSERWS WORK SURFACE, 30" WIDE MINIMUM CLEARANCE
CASEWORK LEGEND
BXX CASEWORK - BASE CABINET, WIDTH INDICATED AS "XX"BXXR CASEWORK - BASE CABINET (REMOVABLE), WIDTH INDICATED AS "XX"DB CASEWORK - DRAWER BASE, WIDTH INDICATED AS "XX"OBXX CASEWORK - OPEN BASE CABINET, WIDTH INDICATED AS "XX"SBXX CASEWORK - SINK BASE, WIDTH INDICATED AS "XX"SBXXR CASEWORK - SINK BASE CABINET (REMOVABLE), WIDTH INDICATED AS "XX"SBXXA CASEWORK - SINK BASE CABINET (ACCESSIBLE), WIDTH INDICATED AS "XX"VBXX CASEWORK - VANITY DRAWER BASE, WIDTH INDICATED AS "XX"VSBXX CASEWORK - VANITY SINK BASE, WIDTH INDICATED AS "XX"VSBXXR CASEWORK - VANITY SINK BASE (REMOVABLE), WIDTH INDICATED AS "XX"WXXYY CASEWORK - 12" DEEP WALL MOUNTED CABINET, WIDTH INDICATED AS "XX", HEIGHT "YY"FEP FINISHED END PANELF FIXED PANELGPNL 12" DEEP X 30" WIDE FRAME AND GYP PANEL TO CONTAIN HOOD VENT, REF: E5/AE361LIN LINEN CABINETPN PANTRY CABINET
10'-9"
3'-0
"1
'-6
"2
'-6
"
7'-0
"
8'-0 1/2"
6'-0
"
B30 B18
W1530 W3312W3012W3030W1830
B18
MWH
RO
REF
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A5
AE361A2
AE361
SOFFIT; REF.AE121
C
7'-0
"
6'-0
"
1'-6
"2
'-6
"3
'-0
"
SB36R
W3012
W3618
RO
MWH
REFS
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
5'-0"
3'-0
"1
'-6
"2
'-6
"
7'-0
"
DW
SB36R B36
W3618 W3030
S
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A3
AE361
E3
AE361
SOFFIT; REF.AE121
PN30
FILLER PANEL,TYP.
FINISHED END PANEL
2'-6
"
W3618
W3012
SB36R
S
RO
MWH
8'-7 1/2"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
11'-0"
8'-3 1/2"
3'-0
"1
'-6
"2
'-6
"
7'-0
"
6'-0
"
MWH
RO
REF
B18B30B21
W2130 W3030 W3012 W1830 W3312
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A2
AE361
A5
AE361
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:
FINISH LEGEND
2'-6
"1
'-6
"3
'-0
"
7'-0
"
6'-0
"7'-0
"
DW
S
RO
MWH
REF
W3012 W3030
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:
FINISH LEGEND
F
5'-0"
3'-0
"1
'-6
"2
'-6
"
7'-0
"
SB36R
W3618 W3030
DW
S
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
05 4500.01COUNTER SUPPORTBRACKET
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A3
AE361
E3
AE361
SOFFIT; REF.AE121
PN30 06 2000.03BASE AS SCHEDULED; RE:FINISH LEGENDFILLER PANEL,
TYP.
FINISHED END PANEL
3'-0
"1
'-6
"2
'-6
"
B36
11'-1"
MWH
RODW
W3030 W3012
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
SOFFIT; REF.AE121
SOFFIT; REF.AE121
2'-2"
3'-0
"1
'-6
"2
'-6
"
7'-0
"
13'-0"
10'-3 1/2"
6'-0
"
W2430 W2130 W3030 W3012 W1830 W3312
B18B30B21B24
RO
MWH
REF
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A2
AE361
A5
AE361
SOFFIT; REF.AE121
1'-6
"2
'-6
"3
'-0
"
7'-0
"
6'-0
"
11'-1"
W3012
W3618
SB36R
RO
MWH
REFS
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:
FINISH LEGEND
F
5'-0"
3'-0
"1
'-6
"2
'-6
"
7'-0
"
SB36R
DW
W3618 W3030
S
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
05 4500.01COUNTER SUPPORTBRACKET
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDSE3
AE361
A3
AE361
SOFFIT; REF.AE121
PN3006 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
FILLER PANEL,TYP.
FINISHED END PANEL
3'-0
"2
'-6
"1
'-6
"
2'-2"
11'-1 1/8"
B36 12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
SB36R
W3618
W3012
MWH
RO
SOFFIT; REF.AE121
SOFFIT; REF.AE121
S
7'-0
"
51B
7'-0 1
/2"
WC
107
TP
C4
AE361
18"
PROVIDE 2X8 BLOCKING; SEE
DETAIL B1/GI000 & A1/GI000 FOR
PLACEMENT OF BLOCKING AND
GRAB BARS, TYP
T/S
TB
E
TPWC
NOTE: LINEN STORAGECABINET NOT SHOWNFOR CLARITY
CR
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
7'-0
"
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
51B
LAV
T/S
TB
CRSH
BF
DB12
MR
TB
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
MR
VB12 VSB36 DB12
2'-10
"
END PANEL,TYP.
LAV
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
09 6500.04BASE AS SCHEDULED
26 0000.01LIGHT FIXTURE, TYP.;REF. ELECT.
VSB36
MR
LAV
209
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
SH
CR
TB
T/S
BF
51B
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
NOTE: LINE STORAGECABINET NOT SHOWNFOR CLARITY
TB
WC
TP
T/S
CR
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
WCTP
TB MR
LAV
VB12 VSB36 DB1212 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
06 4100.09LINEN STORAGE CABINET
7'-0
"
09 6500.04BASE AS SCHEDULED
26 0000.01LIGHT FIXTURE, TYP.;REF. ELECT.
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
E
TB
WC T/S
CR
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
MRMR
SHCR
BF
TB
T/S
LAVLAV
VB33 VB33
7'-0
"
26 0000.01LIGHT FIXTURE, TYP.;REF. ELECT.
DB12 DB12
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
VB18D
G
SHVS
52A3'-2
"
2'-10
"
VB33
2'-0
"2
'-0
"2
'-0
"
51A
LAV
MR
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
TB
09 6500.04BASE AS SCHEDULED
51A
303
WC7'-0
"
51B
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT
OF BLOCKING AND GRAB BARS, TYP
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE221
INTERIORELEVATIONS
RW/JM
20-7002.005
AW/CM
05 4500.01 COUNTER SUPPORT BRACKET
06 2000.03 BASE AS SCHEDULED; RE: FINISH LEGEND
06 4100.09 LINEN STORAGE CABINET
09 6500.04 BASE AS SCHEDULED
12 3600.05 PLASTIC LAMINATE, PL-1 WITH BACKSPLASH, RE: FINISH LEGEND
12 3600.07 PLASTIC LAMINATE, PL-1;RE: FINISH LEGEND
26 0000.01 LIGHT FIXTURE, TYP.; REF. ELECT.
3/8" = 1'-0"A4 1BD/1BA DUPLEX - KITCHEN (LEFT)3/8" = 1'-0"A3 1BD/1BA DUPLEX - KITCHEN (BACK)
3/8" = 1'-0"A2 1BD/1BA DUPLEX - KITCHEN (RIGHT)3/8" = 1'-0"A1 1BD/1BA DUPLEX - KITCHEN (FRONT)
3/8" = 1'-0"B4 2BD/1BA DUPLEX - KITCHEN (LEFT)3/8" = 1'-0"B3 2BD/1BA DUPLEX - KITCHEN (BACK)
3/8" = 1'-0"B2 2BD/1BA DUPLEX - KITCHEN (RIGHT)3/8" = 1'-0"B1 2BD/1BA DUPLEX - KITCHEN (FRONT)
3/8" = 1'-0"C4 3BD/2BA SINGLE-FAMILY - KITCHEN (LEFT)3/8" = 1'-0"C3 3BD/2BA SINGLE-FAMILY - KITCHEN (BACK)
3/8" = 1'-0"C2 3BD/2BA SINGLE-FAMILY - KITCHEN (RIGHT)3/8" = 1'-0"C1 3BD/2BA SINGLE-FAMILY - KITCHEN (FRONT)
3/8" = 1'-0"D6 1BD/1BA DUPLEX - BATH (LEFT)3/8" = 1'-0"D5 1BD/1BA DUPLEX - BATH (BACK)
3/8" = 1'-0"D4 1BD/1BA DUPLEX - BATH (RIGHT)3/8" = 1'-0"D3 1BD/1BA DUPLEX - BATH (FRONT)
3/8" = 1'-0"D2 2BD/1BA DUPLEX - BATH (LEFT)3/8" = 1'-0"D1 2BD/1BA DUPLEX - BATH (BACK)
3/8" = 1'-0"E6 2BD/1BA DUPLEX - BATH (RIGHT)3/8" = 1'-0"E5 2BD/1BA DUPLEX - BATH (FRONT)
3/8" = 1'-0"E4 3BD/2BA S-F - BATH (LEFT)3/8" = 1'-0"E3 3BD/2BA SINGLE-FAMILY - BATH (BACK)
3/8" = 1'-0"E2 3BD/2BA S-F - BATH (RIGHT)3/8" = 1'-0"E1 3BD/2BA SINGLE-FAMILY - BATH (FRONT)
13
13
13
13 01/06/21 ASI-001T
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. DIMENSIONS ARE TO FINISHED FACE, UNLESS NOTED OTHERWISE.B. REFER TO GI000 FOR TYPICAL TOILET ACCESSORY MOUNTING HEIGHTS.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. PROVIDE BLOCKING AT ALL TOILET AND SHOWER LOCATIONS FOR SECURING GRAB BARS.E. COORDINATE WALL DEVICE LOCATIONS WITH WALL MOUNTED FURNISHINGS. F. COORDINATE WALL ACCESS PANEL LOCATIONS AS TO NOT OVERLAP CHANGES IN
FINISHES.G. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. H. REFER TO MECHANICAL, ELECTRICAL AND PLUMBING (MEP) LEGENDS FOR DESCRIPTION
OF MEP-RELATED SYMBOLS.I. DISHWASHER SHOWN FOR LOCATION AND REFERENCE ONLY; NOT IN CONTRACT.J. CONTRACTOR TO SUPPLY AND INSTALL RANGE AND REFRIGERATOR ONLY. ALL OTHER
APPLIANCES BY OWNER AND INSTALLED BY CONTRACTOR.K. ALL INTERIOR FINISHES FLAME SPREAD REQUIREMENTS SHALL BE IN COMPLIANCE WITH
NFPA 5000 (2018), CHAPTER 10.2.L. PAINT ALL GYP. BOARD CEILINGS IN UNITS P-3, UNOM. PAINT ALL GYP BOARD WALLS IN UNITS P-1, UNON. ALL FINISH TRANSITIONS THAT OCCUR AT DOORWAYS TRANSITION MATERIAL AT
CENTERLINE OF DOOR WHEN CLOSEDO. ALL FLOORING TO RUN CONTINOUSLY UNDER APPLIANCES AND AT OPEN CABINET
CONDITIONSP. ALL GYP BOARD WALLS TO RECEIVE WB-1, UNOQ. ALL GYP BOARDS IN RESTROOMS TO RECEIVE RB-1, UNOR. WHERE SHOWER ABUTS OR IS ADJACENT TO EXTERIOR WALL, PROVIDE WEATHER
BARRIER BEHIND SHOWER.S. PROVIDE MOISTURE-RESISTANT GYPSUM WALLBOARD OR CEMENT BOARD (WITH
CAULKED JOINTS) BEHIND TUB AND/OR SHOWER ENCLOSURES.T. DRYWALL SEALED TO TOP PLATE AT ALL UNCONDITIONED ATTIC / WALL INTERFACES
USING CAULK, FOAM, DRYWALL ADHESIVE (BUT NOT OTHER CONSTRUCTION ADHESIVES), OR EQUIVALENT MATERIAL.
U. KITCHEN AND BATHROOM SINK TO HAVE REMOVABLE BASE CABINETS. FLOORING TO EXTEND UNDER SINK BASE FOR ADAPTABLE CONDITION. CONFIRM ADA TYPE SINK
FIXTURE LEGEND
APPLIANCE LEGEND
GENERAL LEGEND
NOTE: REFER TO PLUMBING FIXTURE SCHEDULE FOR MANUFACTURER AND MODEL NUMBERSBF BATH FAUCETGD GARBAGE DISPOSAL, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITSFD FLOOR DRAINLAV LAVATORYRS ROLL-IN SHOWER WITH TILE SURROUNDTUB TUB & SHOWER, VERIFY DIMENSION PER UNITS SINKWC WATER CLOSETSH SHOWER HEADSHWR SHOWERSS SHOWER SEAT
ADA DW ADA DISHWASHER (OWNER PROVIDED, NIC)DW DISHWASHER (OWNER PROVIDED, NIC)ADA REF ADA REFRIGERATORREF REFRIGERATORADA RO ADA ELECTRIC RANGE/ OVENRO RANGE/ OVENW WASHER (OWNER PROVIDED, NIC)D DRYER (OWNER PROVIDED, NIC)MIC MICROWAVE (ADA) ON COUNTERTOP (OWNER PROVIDED, NIC)RH ADA EXHAUST HOOD, SWITCH CONTROLS ARE WITHIN REACH RANGE IN "TYPE A" UNITS WH WATER HEATERF FURNACEMWH MICROWAVE with HOOD (OWNER PROVIDED, NIC)
CR SHOWER CURTAIN RODGBXX GRAB BAR PER ANSI A117.1 XX INDICATES WIDTHMR MIRROR, FULL WIDTH OF VANITY COUNTERTOP R&S ROD & SHELF - WIRE CLOSET SHELVINGRH ROBE HOOKSHVS SHELF - WIRE CLOSET SHELVINGTB TOWEL BARTP TOILET PAPER DISPENSERWS WORK SURFACE, 30" WIDE MINIMUM CLEARANCE
CASEWORK LEGEND
BXX CASEWORK - BASE CABINET, WIDTH INDICATED AS "XX"BXXR CASEWORK - BASE CABINET (REMOVABLE), WIDTH INDICATED AS "XX"DB CASEWORK - DRAWER BASE, WIDTH INDICATED AS "XX"OBXX CASEWORK - OPEN BASE CABINET, WIDTH INDICATED AS "XX"SBXX CASEWORK - SINK BASE, WIDTH INDICATED AS "XX"SBXXR CASEWORK - SINK BASE CABINET (REMOVABLE), WIDTH INDICATED AS "XX"SBXXA CASEWORK - SINK BASE CABINET (ACCESSIBLE), WIDTH INDICATED AS "XX"VBXX CASEWORK - VANITY DRAWER BASE, WIDTH INDICATED AS "XX"VSBXX CASEWORK - VANITY SINK BASE, WIDTH INDICATED AS "XX"VSBXXR CASEWORK - VANITY SINK BASE (REMOVABLE), WIDTH INDICATED AS "XX"WXXYY CASEWORK - 12" DEEP WALL MOUNTED CABINET, WIDTH INDICATED AS "XX", HEIGHT "YY"FEP FINISHED END PANELF FIXED PANELGPNL 12" DEEP X 30" WIDE FRAME AND GYP PANEL TO CONTAIN HOOD VENT, REF: E5/AE361LIN LINEN CABINETPN PANTRY CABINET
2'-10
"1
'-8
"2
'-6
"
7'-0
"
8'-3 1/2"
ADARO
MIC
RH
ADAREF
W2130 W3030 W3012 W1530
B21 B30 B18
8'-3" 2'-10"
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
A5
AE361
SOFFIT; REF.AE121
W3312
RANGE HOOD CONTROLS
44
" M
AX
.
2'-10
"1
'-8
"
7'-0
"
7'-6"
SB36R
W3618 W2430
ADADW
ADAS
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A5
AE361
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
FILLER PANEL,TYP.
B36RPN30A
REMOVABLE BASE CABINET
3'-0"
W3630
REMOVABLE BASE CABINET
3'-0"
6'-0
"
2'-6
"1
'-8
"2
'-10
"
7'-0
"
C
W2430W3012
ADAREF
ADARO
ADADW
ADAS
RH
8'-7 1/2"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
2'-10
"1
'-8
"2
'-6
"
ADADW
MIC
W2430 W3030
B30
8'-7 1/2"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
ADARO
MIC
RH
ADAREF
W1530 W3630 W3012 W1830
B18B36RB15
2'-10
"1
'-8
"2
'-6
"
7'-0
"
8'-3" 2'-10"
8'-3 1/2"
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A5
AE361
SOFFIT; REF.AE121
W3312
06 2000.03BASE AS SCHEDULED; RE:
FINISH LEGEND
44
" M
AX
.
RANGE HOOD CONTROLS
REMOVABLE BASE CABINET
3'-0"
2'-10
"1
'-8
"
7'-0
"
W3618 W2430
SB36R
7'-6"
ADAS
ADADW
05 4500.01COUNTER SUPPORTBRACKET
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A5
AE361
SOFFIT; REF.AE121
PN30A
2'-6"
06 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
FILLER PANEL,TYP.
REMOVABLE BASE CABINET
3'-0"
ADAS
ADARO
RH
ADAREF
W3012 W3630
SB36R
11'-1"
1'-8
"2
'-10
"7
'-0
"
7'-0
"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:
FINISH LEGEND
F
ADARO
MIC
RH
2'-10
"1
'-8
"
7'-0
"
6'-0
"
W3012W3630
SB36R B21
11'-1"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
B15
MIC
RH
W2430 W3012
B21
ADADW
ADARO
11'-1"
2'-10
"1
'-8
"2
'-6
"
7'-0
"
6'-0
"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
B15
W3012 W2430
ADARO
ADADW
ADAS
ADAREF
RH
C
6'-0
" 1'-8
"2
'-10
"
7'-0
"
11'-1"
SOFFIT; REF.AE121
SOFFIT; REF.AE121
06 2000.03BASE AS SCHEDULED; RE:
FINISH LEGEND
10'-3" 2'-10"
W2430 W1830 W3330 W3012 W1830
2'-10
"1
'-8
"
7'-0
"
B24 B18B33R
B18
RH
MIC
ADARO
ADAREF
10'-3 1/2"
12 3600.07PLASTIC LAMINATE,PL-1;RE: FINISH LEGEND
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A5
AE361
SOFFIT; REF.AE121
W3312
RANGE HOOD CONTROLS
REMOVABLE BASE CABINET
2'-9"
2'-10
"1
'-8
"
7'-0
"
7'-6"
ADADW
ADAS
W3630 W3030
SB36R
05 4500.01COUNTER SUPPORTBRACKET
FINISHED END PANEL, TYP. @ EXPOSED ENDS
FINISHED END PANEL, TYP. @ EXPOSED ENDS
A5
AE361
SOFFIT; REF.AE121
PN30A
2'-6"
06 2000.03BASE AS SCHEDULED; RE:FINISH LEGEND
FILLER PANEL,TYP.
FINISHED END PANEL
REMOVABLE BASE CABINET
3'-0"
WCA107
TP
51B
7'-0 1
/2"
5'-0"
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND GRAB BARS
GB36
GB
18
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL
B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND
GRAB BARS
E
WC
TP
CR
TB
3'-0"
GB42
GB
18
09 6500.04BASE AS SCHEDULED
VB12D
51B
TB
SH
LAV
CR
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND GRAB BARS
3'-0"
5'-0"
TB
GB36
GB
18
09 6500.04BASE AS SCHEDULED
VB12 VB12D
LAV
MR
CLEAR
2'-6"
2'-10
"
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
END PANEL,TYP. @ EXPOSED ENDS
VSB36A
E5
AE361
A4
AE361
26 0000.01LIGHT FIXTURE, TYP.;REF. ELECT.
ADALAV
MR
A209
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND GRAB BARS
51A
TB
CR
3'-0"
5'-2 1/8"
GB15
GB
18
09 6500.04BASE AS SCHEDULED
SH
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND GRAB BARS
CR
WC
TP
WC
TB
GB32
GB
18
GB42
GB
18
09 6500.04BASE AS SCHEDULED
WC
TP
ADALAV
MR
VB18DPROVIDE 2X8 BLOCKING, INSTALL
GRAB BARS TYP; SEE DETAIL B1/GI000 & A1/GI000 FOR
PLACEMENT OF BLOCKING AND GRAB BARS
VSB36A
E5
AE361
A4
AE361
GB36
GB
18
09 6500.04BASE AS SCHEDULED
26 0000.01LIGHT FIXTURE, TYP.;REF. ELECT.
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL
B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND
GRAB BARS
WC
TB
CR
E
GB42
GB
18
09 6500.04BASE AS SCHEDULED
E
ADALAV
ADALAV
SH
CR
TB
VB36VSB36A
CLEAR
3'-0"
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
5'-1"
7'-0 1
/2"
MR MR
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL B1/GI000 FOR
PLACEMENT OF BLOCKING AND GRAB BARS
FILLER PANEL,TYP.
VSB36A
E5
AE361
A5
AE361SIM
GB18
GB
18
09 6500.04BASE AS SCHEDULED
26 0000.01LIGHT FIXTURE, TYP.;REF. ELECT.
SHVS
1'-0
"2
'-0
"2
'-0
"
2'-10
"
OPEN
ADALAV
MR
52A
12 3600.05PLASTIC LAMINATE, PL-1WITH BACKSPLASH, RE:FINISH LEGEND
3'-2
"
51A
09 6500.04BASE AS SCHEDULED
PROVIDE 2X8 BLOCKING, INSTALL GRAB BARS TYP; SEE DETAIL B1/GI000 & A1/GI000 FOR PLACEMENT OF BLOCKING AND GRAB BARS
5'-1"
51B
51A
A303
WC
7'-0 1
/2"
GB36
GB
18
18"
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE222
INTERIORELEVATIONS -TYPE 'A' UNITS
RW/JM
20-7002.005
AW
05 4500.01 COUNTER SUPPORT BRACKET
06 2000.03 BASE AS SCHEDULED; RE: FINISH LEGEND
09 6500.04 BASE AS SCHEDULED
12 3600.05 PLASTIC LAMINATE, PL-1 WITH BACKSPLASH, RE: FINISH LEGEND
12 3600.07 PLASTIC LAMINATE, PL-1;RE: FINISH LEGEND
26 0000.01 LIGHT FIXTURE, TYP.; REF. ELECT.
3/8" = 1'-0"A4 1BD/1BA DUPLEX - KITCHEN (LEFT) TYPE 'A'3/8" = 1'-0"A2 1BD/1BA DUPLEX - KITCHEN (RIGHT) TYPE 'A'
3/8" = 1'-0"A3 1BD/1BA DUPLEX - KITCHEN (BACK) TYPE 'A'3/8" = 1'-0"A1 1BD/1BA DUPLEX - KITCHEN (FRONT) TYPE 'A'
3/8" = 1'-0"B4 2BD/1BA DUPLEX - KITCHEN (LEFT) TYPE 'A'3/8" = 1'-0"B2 2BD/1BA DUPLEX - KITCHEN (RIGHT) TYPE 'A'
3/8" = 1'-0"C3 3BD/2BA SINGLE-FAMILY - KITCHEN (BACK) TYPE 'A'3/8" = 1'-0"C1 3BD/2BA SINGLE-FAMILY - KITCHEN (FRONT) TYPE 'A'
3/8" = 1'-0"B1 2BD/1BA DUPLEX - KITCHEN (FRONT) TYPE 'A'3/8" = 1'-0"B3 2BD/1BA DUPLEX - KITCHEN (BACK) TYPE 'A'
3/8" = 1'-0"C4 3BD/2BA SINGLE-FAMILY - KITCHEN (LEFT) TYPE 'A'3/8" = 1'-0"C2 3BD/2BA SINGLE-FAMILY - KITCHEN (RIGHT) TYPE 'A'
3/8" = 1'-0"D6 1/1 DUPLEX - BATH (LEFT) TYPE 'A'3/8" = 1'-0"D5 1/1 DUPLEX - BATH (BACK) TYPE 'A'
3/8" = 1'-0"D4 1/1 DUPLEX - BATH (RIGHT) TYPE 'A'3/8" = 1'-0"D3 1/1 DUPLEX - BATH (FRONT) TYPE 'A'
3/8" = 1'-0"D2 2/1 DUPLEX - BATH (L) TYPE 'A'3/8" = 1'-0"D1 2/1 DUPLEX - BATH (BACK) TYPE 'A'
3/8" = 1'-0"E6 2/1 DUPLEX - BATH (R) TYPE 'A'3/8" = 1'-0"E5 2/1 DUPLEX - BATH (FRONT) TYPE 'A'
3/8" = 1'-0"E4 3/2 S-F - BATH (L) TYPE 'A'3/8" = 1'-0"E3 3/2 SINGLE-FAMILY - BATH (BACK) TYPE 'A'
3/8" = 1'-0"E2 3/2 S-F - BATH (R) TYPE 'A'3/8" = 1'-0"E1 3/2 SINGLE-FAMILY - BATH (FRONT) TYPE 'A'
13
13
13 01/06/21 ASI-001T
REFERENCE KEYNOTES
GENERAL SHEET NOTESA. REFER TO SHEET AE001 FOR EXPLANATION OF ENCLOSURE ASSEMBLIES.B. REFER TO SHEET AE002 FOR ENCLOSURE CONTINUITY FOR CONTROL LAYER CONTINUITY
INTENT.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR
EXTERIOR WALL TYPE DESCRIPTIONS.E. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR
WALL TYPE DESCRIPTIONS.F. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE
DESCRIPTIONS.G. AT BUILDING SECTIONS, ROOF TRUSS LOCATIONS SHOWN FOR REFERENCE ONLY.
REFERENCE STRUCTURAL DRAWINGS FOR ACTUAL ROOF TRUSS LOCATIONS.H. AT BUILDING SECTIONS, ROOF TRUSS DIAGONALS SHOWN FOR REFERENCE ONLY.
ACTUAL ROOF TRUSS DIAGONALS TO BE DETERMINED BY MANUFACTURER.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE
EXTERIOR GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF
MEP-RELATED SYMBOLS.L. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND
INSTALLED BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.M. FOR WINDOW TYPES A, A1 & B, VERIFY FIXED WINDOW SIDE PER ELEVATIONS AND PLANS.N. PROVIDE R-5 BLANKET INSULATION OVER FIRE SPRINKLER SYSTEM AND DUCTWORK.O. ALL EXTERIOR DOORS AND OPERABLE WINDOWS TO RECEIVE WEATHERSTRIPPING AND
SEALED.P. INSTALL INSULATION TO BE INSTALLED TO RESNET GRADE 1 STANDARDS.Q. DUCTS, FLUES, SHAFTS, PLUMBING, PIPING, WIRING, EXHAUST FANS, & OTHER
PENETRATIONS TO UNCONDITIONED SPACE SEALED, WITH BLOCKING / FLASHING AS NECESSARY.
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52A
INTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
CEMENT FIBER HORIZONTAL LAP SIDING (6" EXPOSURE)
WOOD_CEDAR
LEGEND
ROOFING_METAL PANEL
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
B5
AE301
AE301
D3
AE301
D2
KITCHEN101
LIVING/DINING100
AE301
D3Sim
AE301
D2Sim
4" / 1'-0"
CB
110
4" / 1'-0"
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
A5
AE301
AE301
D5
A3
AE301
B2
AE301
LIVING/DINING100
BEDROOM108
BEDROOM128
LIVING/DINING120
AE301
D5Sim
108105 128 125
D1EXTEND TOUNDERSIDE OFSHEATHING
51B
51B
C C
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
AE561
C1Sim
AE561
C3Sim
LIVING/DINING
W1C
R1
AE501
C1Sim
06 1000.03O.S.B. SHEATHING, REF:STRUCT.
03 3000.02CONCRETE FOUNDATION;REF. STRUCT.
AE501
A4
06 1733.03WOOD TRUSS. REF:STRUCT.
2'-0
"
TAMP BACKFILL AND PROVIDEPOSITIVE DRAINAGE AWAY
FROM BUILDING (MIN. 0.5"/1'-0" FOR 10'-0")
2'-4
"
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
B5
AE301
AE301
D4
BEDROOM128
BATH127
BATH127
AE301
D3Sim
4" / 1'-0"
4" / 1'-0"
51B
E
A
129127
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
BATH
AE561
C3Sim
AE561
C1Sim
E
R1
AE501
B3Sim
06 1000.03O.S.B. SHEATHING, REF:STRUCT.
03 3000.02CONCRETE FOUNDATION;REF. STRUCT.
AE501
A4
06 1733.03WOOD TRUSS. REF:STRUCT.
2'-0
"
TAMP BACKFILL AND PROVIDEPOSITIVE DRAINAGE AWAY
FROM BUILDING (MIN. 0.5"/1'-0" FOR 10'-0")
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
AE561
C3Sim
AE561
C1Sim
LIVING/DININGB
W1
R1
03 3000.02CONCRETE FOUNDATION;REF. STRUCT.
06 1733.03WOOD TRUSS. REF:STRUCT.
AE501
A3
06 1000.03O.S.B. SHEATHING, REF:STRUCT.
AE501
B1Sim
2'-0
"
NOTE: PROVIDE SELF-ADHERING WEATHER BARRIER AT ALL ROOF VALLEYS AND ROOF DECK PENETRATIONS
1'-8
"
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
R1
03 3000.04CONCRETE SLAB ONGRADE , REF. STRUCT.
AE501
C1
06 1733.03WOOD TRUSS. REF:STRUCT.
07 4646.03FIBER CEMENT TRIM
W2A
TAMP BACKFILL AND PROVIDEPOSITIVE DRAINAGE AWAY
FROM BUILDING (MIN. 0.5"/1'-0" FOR 10'-0")
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
B5
AE301
BEDROOM108
HALL105
AE301
D1AE302
D1Sim
4" / 1'-0"
4" / 1'-0"
MECH.103
AE301
D2Sim
STORAGE110
W2
1072'-0
"
F2
LEVEL 1100' - 0"
ROOF BEARING108' - 1"
W1
R1
AE501
B3
06 1733.03WOOD TRUSS. REF:STRUCT.
03 3000.02CONCRETE FOUNDATION;REF. STRUCT.
AE501
A4
2'-0
"
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE301
1BD/1BA DUPLEX- BUILDING / WALLSECTIONS
RW/JM
20-7002.005
AW
03 3000.02 CONCRETE FOUNDATION; REF. STRUCT.
03 3000.04 CONCRETE SLAB ON GRADE
06 1000.03 O.S.B. SHEATHING, REF: STRUCT.
06 1000.07 DIMENSIONAL CEDAR LINTEL, REF: STRUCT.
06 1733.03 WOOD TRUSS. REF: STRUCT.
07 4646.03 FIBER CEMENT TRIM
1/4" = 1'-0"A5 1BD/1BA DUPLEX - BUILDING SECTION - KITCHEN/LIVING
1/4" = 1'-0"B5 1BD/1BA DUPLEX - BUILDING SECTION - LIVING/BEDROOM
1/2" = 1'-0"D5 TYPICAL WALL SECTION AT GABLE WALL
1/4" = 1'-0"A3 1BD/1BA DUPLEX - BUILDING SECTION - BEDROOM/BATH
1/2" = 1'-0"D4 TYPICAL WALL SECTION AT HIGH WINDOW1/2" = 1'-0"D3 WALL SECTION AT ROOF INTERSECTION
1/2" = 1'-0"D2 TYPICAL WALL SECTION AT PORCH/PATIO
1/4" = 1'-0"B2 1BD/1BA DUPLEX - BUILDING SECTION - LAUNDRY/HALL/BEDROOM
1/2" = 1'-0"D1 TYPICAL WALL SECTION
13
13
13 01/06/21 ASI-001T
REFERENCE KEYNOTES
GENERAL SHEET NOTES
A. DIMENSIONS ARE TO FINISHED FACE, UNLESS NOTED OTHERWISE.B. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.C. COORDINATE CASEWORK WITH SOFFIT LOCATIONS, NOT ALL SOFFITS SHOWN IN SECTION,
CASEWORK UNDER 7'-2" AFF SOFFIT TO RECEIVE SCRIBE/FILLER WITH CONTINUOUS LAMINATE.
D. REFERENCE INTERIOR ELEVATIONS FOR CASEWORK FINISH INFORMATION.E. ALL SHELVING CABINETS OVER 36"W REQUIRE A MIDDLE VERTICAL SUPPORT.F. PROVIDE COUNTER SUPPORTS EVERY 36” MINIMUM.G. PROVIDE CONTINUOUS SOLID BACKING UNDER COUNTERTOP FOR FULL LENGTH OF
SUPPORT
CASEWORK LEGEND
BXX CASEWORK - BASE CABINET, WIDTH INDICATED AS "XX"DB CASEWORK - DRAWER BASE, WIDTH INDICATED AS "XX"OBXX CASEWORK - OPEN BASE CABINET, WIDTH INDICATED AS "XX"SBXX CASEWORK - SINK BASE, WIDTH INDICATED AS "XX"VBXX CASEWORK - VANITY DRAWER BASE, WIDTH INDICATED AS "XX"VSBXX CASEWORK - VANITY SINK BASE, WIDTH INDICATED AS "XX"WXXYY CASEWORK - 12" DEEP WALL MOUNTED CABINET, WIDTH INDICATED AS "XX", HEIGHT AS "YY"FEP FINISHED END PANELF FIXED PANELGPNL 12" DEEP X 30" WIDE FRAME AND GYP PANEL TO CONTAIN HOOD VENT, REF: E5/AE361LIN LINEN CABINETPAN PANTRY CABINET
SEE UNIT PLANS FORPARTITION TYPE
2X BLOCKING, TYPICAL
SINK
EXTEND FLOORING UNDER REMOVABLE
CABINET
SEALANT, CONTINUOUS
REMOVABLE* CABINET
34"
TILE BACKSPLASH
COUNTERTOP TO BE SUPPORTED BY ADJACENTCABINET WITH FINISHED END PANEL*
BUILT-IN APRON*
GARBAGE DISPOSAL
25"
24"
WALL BASE AS SCHEDULED
SEE UNIT PLANS FORPARTITION TYPE
2X BLOCKING, TYPICAL
REMOVABLE PANEL, BRACE AS NEEDED
SINK
FLOOR FINISH AS SCHEDULED
SOLID SURFACE COUNTERTOP AND
BACKSPLASH
SEALANT, CONTINUOUS
34"
MIN
.
9 1
/2"
MIN.
11"
CLE
AR
MIN
.
27"
MIN.
8"
24"ELECTRICAL
OUTLET
SOLID SURFACE CAP
25"
38"
WALL BASE AS SCHEDULED
SEE UNIT PLANS FORPARTITION TYPE
2X BLOCKING, TYPICAL
REMOVABLE PANEL, BRACE AS NEEDED
SINK
FLOOR FINISH AS SCHEDULED
SOLID SURFACE COUNTERTOP AND
BACKSPLASH
SEALANT, CONTINUOUS
34"
MIN
.
9 1
/2"
MIN.
11"
CLE
AR
MIN
.
27"
MIN.
8"
24"
25"
36"
2"
4"
PLASTIC LAMINATE, PL-1;RE:FINISH LEGEND
4" WIRE PULL, TYP.
BASIC WOOD SHELVING;MAX DEPTH 12"
WALL CABINET
37"
24"
METAL BRACKET SUPPORT
12"
34
1/2
"
FINISHED END PANEL
36"
84"
30"
12"
25"
PLASTIC LAMINATE DOORWITH CONCEALED HINGE
4" WIRE PULL, TYP.
1 1/2" THICK COUNTERTOP,PROVIDE BACKSPLASH ANDSIDE SPLASH WHEREAPPLICABLE
DISHWASHER
CASEWORK BEYOND
BASIC WOOD SHELVING;MAX DEPTH 12"
MELAMINE FINISH
BLOCKING AS REQUIRED
84"
PLASTIC LAMINATE DOORWITH CONCEALED HINGE
4" WIRE PULL, TYP.
CASEWORK BEYOND
RESILIENT BASE, RE: FINISHLEGEND
BASIC WOOD SHELVING;MAX DEPTH 12"
24"
2"
4"
BLOCKING AS REQUIRED
ADJUSTABLE SHELF WITHMELAMINE FINISH
FIXED SHELF
30"
12"
24"
4" WIRE PULL, TYP.
PLASTIC LAMINATE FULLEXTENSION DRAWER
MELAMINE FINISH
BASIC WOOD SHELVING;MAX DEPTH 12"
36"
2"
4"
1 1/2" THICK COUNTERTOP,PROVIDE BACKSPLASH ANDSIDE SPLASH WHEREAPPLICABLE
4" WIRE PULL, TYP.
BASIC WOOD SHELVING;MAX DEPTH 12"
CASEWORK BEYOND
BASE AS SCHEDULED
PLASTIC LAMINATE DOORWITH CONCEALED HINGE
BLOCKING AS REQUIRED
84"
25"
36"
24"
2"
4"
6"
6"
6"
1 1/2" THICK COUNTERTOP,PROVIDE BACKSPLASH ANDSIDE SPLASH WHEREAPPLICABLE
4" WIRE PULL, TYP.
PLASTIC LAMINATE FULLEXTENSION DRAWER
BASE AS SCHEDULED
BLOCKING AS REQUIRED
25"
58"
6"
20"
84"
12"
4" WIRE PULL, TYP.
PLASTIC LAMINATE DOORWITH CONCEALED HINGE
RANGE
BLOCKING AS REQUIRED
HOOD
VENTING
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE361
CASEWORKSECTIONS
RW/JM
20-7002.005
AW
06 4100.02 WALL CABINET
06 4100.07 ADJUSTABLE SHELF WITH MELAMINE FINISH
06 4100.08 BASIC WOOD SHELVING; MAX DEPTH 12"
06 4100.10 4" WIRE PULL, TYP.
06 4100.11 PLASTIC LAMINATE FULL EXTENSION DRAWER
06 4100.12 PLASTIC LAMINATE DOOR WITH CONCEALED HINGE
06 4100.13 BLOCKING AS REQUIRED
06 4100.14 MELAMINE FINISH
06 4100.15 CASEWORK BEYOND
06 4100.16 FIXED SHELF
09 6500.01 RESILIENT BASE, RE: FINISH LEGEND
09 6500.04 BASE AS SCHEDULED
11 3013.02 RANGE
11 3013.08 DISHWASHER
11 3013.11 HOOD
12 3600.07 PLASTIC LAMINATE, PL-1;RE: FINISH LEGEND
12 3600.08 1 1/2" THICK COUNTERTOP, PROVIDE BACKSPLASH AND SIDE SPLASH WHEREAPPLICABLE
1" = 1'-0"E3 ACCESSIBLE KITCHEN SINK BASE CABINET1" = 1'-0"E4 ACCESSIBLE VANITY SINK @ FURRED WALL
1" = 1'-0"E5 ACCESSIBLE VANITY SINK, TYP.
1" = 1'-0"A1 PENINSULA w/ BASE CABINET1" = 1'-0"A3 DISHWASHER w/ WALL CABINET
1" = 1'-0"C4 CASEWORK - TALL CABINET
1" = 1'-0"A5 BASE & WALL CABINETS1" = 1'-0"A4 BASE (w/ DRAWERS) & WALL CABINETS
1" = 1'-0"A2 CASEWORK - RANGE w/ WALL CABINET
13
13
13
13
13 13
13
13 01/06/21 ASI-001T
REFERENCE KEYNOTES
GENERAL SHEET NOTESA. REFER TO SHEET AE001 FOR EXPLANATION OF ENCLOSURE ASSEMBLIES.B. REFER TO SHEET AE002 FOR ENCLOSURE CONTINUITY FOR CONTROL LAYER CONTINUITY
INTENT.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR
EXTERIOR WALL TYPE DESCRIPTIONS.E. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR
WALL TYPE DESCRIPTIONS.F. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE
DESCRIPTIONS.G. AT BUILDING SECTIONS, ROOF TRUSS LOCATIONS SHOWN FOR REFERENCE ONLY.
REFERENCE STRUCTURAL DRAWINGS FOR ACTUAL ROOF TRUSS LOCATIONS.H. AT BUILDING SECTIONS, ROOF TRUSS DIAGONALS SHOWN FOR REFERENCE ONLY.
ACTUAL ROOF TRUSS DIAGONALS TO BE DETERMINED BY MANUFACTURER.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE
EXTERIOR GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF
MEP-RELATED SYMBOLS.L. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND
INSTALLED BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.M. FOR WINDOW TYPES A, A1 & B, VERIFY FIXED WINDOW SIDE PER ELEVATIONS AND PLANS.N. PROVIDE R-5 BLANKET INSULATION OVER FIRE SPRINKLER SYSTEM AND DUCTWORK.O. ALL EXTERIOR DOORS AND OPERABLE WINDOWS TO RECEIVE WEATHERSTRIPPING AND
SEALED.P. INSTALL INSULATION TO BE INSTALLED TO RESNET GRADE 1 STANDARDS.Q. DUCTS, FLUES, SHAFTS, PLUMBING, PIPING, WIRING, EXHAUST FANS, & OTHER
PENETRATIONS TO UNCONDITIONED SPACE SEALED, WITH BLOCKING / FLASHING AS NECESSARY.
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52A
INTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
07 9200.02SEALANT
07 2500.01BUILDING WRAP/PAPER
03 0516.01UNDER-SLAB VAPORRETARDER
03 3000.02CONCRETE FOUNDATION;REF. STRUCT.
03 3000.04CONCRETE SLAB ONGRADE
07 2100.012" FOAM BOARD
PERIMETER INSULATION(R-10)
07 2500.02SELF-ADHERED FLEXIBLE
FLASHING
07 6200.01METAL FLASHING
W1 W2
07 4646.04STARTER STRIP
03 3000.19GRAVEL BASE
06 1000.15FOAM SILL PLATE SEALER
07 2100.10PARGE PLUS BY TRUEFOAM APPLIED OVER
PRIMER
6"
MIN
.6
" M
IN
07 4646.05FURRING STRIP
06 1000.03O.S.B. SHEATHING, REF:
STRUCT.
4"
1"
NOTE: COLOR TO MATCH ADJACENT PLANK SIDING
ROOF BEARING108' - 1"
07 4646.08FIBER CEMENT SOFFITBOARD
07 9200.01BACKER ROD ANDSEALANT
07 4646.06FIBER CEMENT FASCIABOARD
06 1000.09BLOCKING AS REQUIRED
W1
07 6200.04METAL GUTTER
R1
09 2116.02GYPSUM WALLBOARD
07 9200.02SEALANT
07 9200.01BACKER ROD ANDSEALANT
07 2500.01BUILDING WRAP/PAPER
07 2500.01BUILDING WRAP/PAPER
07 9200.02SEALANT
06 1000.09BLOCKING AS REQUIRED
07 4646.05FURRING STRIP07 4646.05FURRING STRIP
07 4646.03FIBER CEMENT TRIM
1"
06 1000.09BLOCKING AS REQUIRED
07 2500.05SELF-ADHERINGPOLYMER-MODIFIEDBITUMEN
EXTEND 24" UP ROOF SLOPE FROM INSIDE FACE OF EXTERIOR WALL FRAMING
06 1733.03WOOD TRUSS. REF:STRUCT.
- AT CORNERS/TOP OFWALL, SIZE = 5/4x4
1 3
/4"
ROOF BEARING108' - 1"
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
07 4646.06FIBER CEMENT FASCIABOARD
06 1000.09BLOCKING AS REQUIRED
07 9200.01BACKER ROD ANDSEALANT
07 9200.01BACKER ROD ANDSEALANT
07 2500.01BUILDING WRAP/PAPER
07 4646.08FIBER CEMENT SOFFITBOARD
06 1000.09BLOCKING AS REQUIRED
07 2500.05SELF-ADHERINGPOLYMER-MODIFIEDBITUMEN
07 9200.01BACKER ROD ANDSEALANT
07 4646.08FIBER CEMENT SOFFITBOARD
3"
07 4646.03FIBER CEMENT TRIM
1 3
/4"
- SIZE = 5/4x4
1/2"
06 1733.03WOOD TRUSS. REF:STRUCT.
07 4646.02FIBER CEMENT PLANK
06 1000.03O.S.B. SHEATHING, REF:STRUCT.
06 1733.032x DIAGONAL; REF. STRUCT.
-OR- WALL TYPE W1 OR W2;REF. PLANS
07 9200.02SEALANT
AT PORCH ONLY
06 1733.032x OUTRIGGER; REF.STRUCT.
07 2100.03BATT/BLANKETINSULATION - R38
AT INSULATED EXTERIOR WALL CONDITION ONLY,
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
07 9200.02SEALANT
07 4646.03FIBER CEMENT TRIM
07 2500.01BUILDING WRAP/PAPER
07 4646.02FIBER CEMENT PLANK
07 4646.05FURRING STRIP
W1
W1
W2
07 9200.02SEALANT
07 4646.02FIBER CEMENT PLANK
07 4646.03FIBER CEMENT TRIM
07 2500.01BUILDING WRAP/PAPER
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
07 9200.02SEALANT
07 9200.02SEALANT
07 4646.05FURRING STRIP
07 4646.05FURRING STRIP
07 4646.02FIBER CEMENT PLANK
07 4646.02FIBER CEMENT PLANK
W1 W2
2x4 LADDERBLOCKING @24" O.C. VERT.
R1
07 4646.08FIBER CEMENT SOFFITBOARD
06 1000.09BLOCKING AS REQUIRED
W1
06 1000.03O.S.B. SHEATHING, REF:STRUCT.
07 2100.02BATT/BLANKETINSULATION - R19
06 1000.05WOOD LEDGER, REF:STRUCT.
07 2500.01BUILDING WRAP/PAPER
07 2500.01BUILDING WRAP/PAPER07 2500.01BUILDING WRAP/PAPER
07 4646.03FIBER CEMENT TRIM
07 2500.01BUILDING WRAP/PAPER
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
07 9200.02SEALANT
07 9200.02SEALANT
(ABOVE)
06 1000.07DIMENSIONAL CEDARLINTEL, REF: STRUCT.
W2
W2
07 4646.02FIBER CEMENT PLANK
07 4646.02FIBER CEMENT PLANK
06 1000.14DIMENSION WOODCOLUMN; REF. STRUCT.
06 1000.03O.S.B. SHEATHING, REF:STRUCT.
07 9200.02SEALANT
07 6200.01METAL FLASHING
06 1000.09BLOCKING AS REQUIRED
07 4646.03FIBER CEMENT TRIM
1/4
"
07 4646.02FIBER CEMENT PLANK
?
07 4646.05FURRING STRIP
07 4646.04STARTER STRIP
06 1000.09BLOCKING AS REQUIRED
W1
ROOF BEARING108' - 1"
W1
07 9200.01BACKER ROD ANDSEALANT
07 2500.01BUILDING WRAP/PAPER
07 9200.02SEALANT
07 4646.05FURRING STRIP07 4646.05FURRING STRIP
07 4646.03FIBER CEMENT TRIM
- AT CORNERS/TOP OFWALL, SIZE = 5/4x4
06 1000.03O.S.B. SHEATHING, REF:STRUCT.- EXTEND TO ROOF DECK
06 1000.09BLOCKING AS REQUIRED06 1000.09BLOCKING AS REQUIRED
07 2100.02BATT/BLANKETINSULATION - R19
- EXTEND TO ROOF DECK
06 1733.03WOOD TRUSS. REF:STRUCT.
51B
52A
52A
52A
RADON MITIGATIONSYSTEM PIPING, TYP.;VENT THROUGH ROOF
8"
1'-0"
09 2116.07CORNER BEAD
07 2100.02BATT/BLANKETINSULATION - R19
POURABLE SEALANT
6" PVC VTR
VAPOR BARRIER
3/4"x4'-0"x4'-0" PRESSURE -TREATED EXTERIOR GRADE PLYWOOD SHEATHING
4'-0" SQUARE PIT
8"x8"x10" DEEP CONCRETE BLOCK AT EACH CORNER OF PLYWOOD, (4) TOTAL
PERFORATED PIPE
SEE PLUMBING AND ARCHITECTURAL FOR ADDITIONAL INFORMATION.
10" DEEP COMPACTED CRUSHED AGGREGATE MEETING SIZE #5 SPECIFICATIONS AS DEFINED IN ASTM C-33-90, PER ARCHITECTURAL RADON REQUIREMENTS
07 9200.02SEALANT
07 2500.01BUILDING WRAP/PAPER
03 3000.02CONCRETE FOUNDATION;REF. STRUCT.
03 3000.04CONCRETE SLAB ONGRADE03 3000.08
EXPANSION/ISOLATIONJOINT
EXTEND MIN. 6" BELOW FINISH GRADE
W1 W2
07 2500.02SELF-ADHERED FLEXIBLE
FLASHING
07 4646.05FURRING STRIP
03 3000.19GRAVEL BASE
06 1000.15FOAM SILL PLATE SEALER
03 0516.01UNDER-SLAB VAPORRETARDER
NOTE: POURABLE SEALANTAT ALL LOCATIONS WHERESLAB MEETS FOUNDATIONWALL OR WHERE SLAB ISPENETRATED.
07 2100.062" FOAM BOARD
PERIMETER INSULATION(R-10)
07 2100.10PARGE PLUS BY TRUEFOAM APPLIED OVER
PRIMER
06 1000.03O.S.B. SHEATHING, REF:
STRUCT.
4"
2"
MIN
1"
NOTE: COLOR TO MATCH ADJACENT PLANK SIDING
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE501
ENLARGEDDETAILS
RW/JM
20-7002.005
AW
03 0516.01 UNDER-SLAB VAPOR RETARDER
03 3000.02 CONCRETE FOUNDATION; REF. STRUCT.
03 3000.04 CONCRETE SLAB ON GRADE
03 3000.08 EXPANSION/ISOLATION JOINT
03 3000.19 GRAVEL BASE
06 1000.03 O.S.B. SHEATHING, REF: STRUCT.
06 1000.05 WOOD LEDGER, REF: STRUCT.
06 1000.07 DIMENSIONAL CEDAR LINTEL, REF: STRUCT.
06 1000.09 BLOCKING AS REQUIRED
06 1000.14 DIMENSION WOOD COLUMN; REF. STRUCT.
06 1000.15 FOAM SILL PLATE SEALER
06 1733.03 WOOD TRUSS. REF: STRUCT.
07 2100.01 2" FOAM BOARD PERIMETER INSULATION (R-10)
07 2100.02 BATT/BLANKET INSULATION - R19
07 2100.03 BATT/BLANKET INSULATION - R38
07 2100.06 2" FOAM BOARD PERIMETER INSULATION (R-10)
07 2100.10 PARGE PLUS BY TRUE FOAM APPLIED OVER PRIMER
07 2500.01 BUILDING WRAP/PAPER
07 2500.02 SELF-ADHERED FLEXIBLE FLASHING
07 2500.05 SELF-ADHERING POLYMER-MODIFIED BITUMEN
07 4646.02 FIBER CEMENT PLANK
07 4646.03 FIBER CEMENT TRIM
07 4646.04 STARTER STRIP
07 4646.05 FURRING STRIP
07 4646.06 FIBER CEMENT FASCIA BOARD
07 4646.08 FIBER CEMENT SOFFIT BOARD
07 6200.01 METAL FLASHING
07 6200.04 METAL GUTTER
07 9200.01 BACKER ROD AND SEALANT
07 9200.02 SEALANT
09 2116.02 GYPSUM WALLBOARD
09 2116.07 CORNER BEAD
3" = 1'-0"A4 DETAIL - TYPICAL WALL BASE AT GRADE
3" = 1'-0"B3 DETAIL - TYPICAL ROOF EAVE
3" = 1'-0"C1 DETAIL - TYPICAL GABLE END WALL (PORCH CONDITION SHOWN)
3" = 1'-0"D5 PLAN DETAIL - TYP INSIDE CORNER3" = 1'-0"D4 PLAN DETAIL - TYP OUTSIDE CORNER
3" = 1'-0"B1 DETAIL AT OVERFRAME ROOF
3" = 1'-0"D3 OUTSIDE CORNER AT STORAGE ROOM/COLUMN
3" = 1'-0"C5 SECTION DETAIL - FIXTURE PENETRATION AT EXTR
3" = 1'-0"B5 DETAIL - 3BD/2BA PORCH OVERHANG
1 1/2" = 1'-0"C3 PLAN DETAIL - RADON PIPE CHASE3/4" = 1'-0"C4 DETAIL - RADON SUCTION PIT
13
13 01/06/21 ASI-001T
3" = 1'-0"A3 DETAIL - TYPICAL WALL BASE AT NON-ENTRY SLAB
GLAZING LEGEND
REFERENCE KEYNOTES
GENERAL SHEET NOTESA. REFER TO SHEET AE001 FOR EXPLANATION OF ENCLOSURE ASSEMBLIES.B. REFER TO SHEET AE002 FOR ENCLOSURE CONTINUITY FOR CONTROL LAYER CONTINUITY
INTENT.C. PROVIDE BACKING FOR SECURING WALL MOUNTED ITEMS.D. EXTERIOR WALLS TO BE TYPE W1, UNLESS NOTED OTHERWISE. REF. GI000 FOR
EXTERIOR WALL TYPE DESCRIPTIONS.E. INTERIOR WALLS TO BE TYPE 51A, UNLESS NOTED OTHERWISE. REF. GI000 FOR INTERIOR
WALL TYPE DESCRIPTIONS.F. ROOFS TO BE TYPE R1, UNLESS NOTED OTHERWISE. REF. GI000 FOR ROOF TYPE
DESCRIPTIONS.G. AT BUILDING SECTIONS, ROOF TRUSS LOCATIONS SHOWN FOR REFERENCE ONLY.
REFERENCE STRUCTURAL DRAWINGS FOR ACTUAL ROOF TRUSS LOCATIONS.H. AT BUILDING SECTIONS, ROOF TRUSS DIAGONALS SHOWN FOR REFERENCE ONLY.
ACTUAL ROOF TRUSS DIAGONALS TO BE DETERMINED BY MANUFACTURER.I. DIVERT WATER AWAY FROM BUILDING WALLS AND FOUNDATIONS BY SLOPING THE
EXTERIOR GRADE AWAY FROM THE BUILDING AND PROVIDING A COBBLE RUN-DOWN AT EACH ROOF DRAIN DOWNSPOUT.
J. REFER TO MECHANICAL SHEETS FOR DUCT AND ROOF PENETRATION LOCATIONS. K. REFER TO MECHANICAL, ELECTRICAL, AND PLUMBING LEGENDS FOR DESCRIPTION OF
MEP-RELATED SYMBOLS.L. SIZE/LOCATION OF RADON SYSTEM IS FOR REFERENCE ONLY; TO BE DESIGNED AND
INSTALLED BY OWNER'S VENDOR PER REQ'S OF AUTHORITIES HAVING JURISDICTION.M. FOR WINDOW TYPES A, A1 & B, VERIFY FIXED WINDOW SIDE PER ELEVATIONS AND PLANS.N. PROVIDE R-5 BLANKET INSULATION OVER FIRE SPRINKLER SYSTEM AND DUCTWORK.O. ALL EXTERIOR DOORS AND OPERABLE WINDOWS TO RECEIVE WEATHERSTRIPPING AND
SEALED.P. INSTALL INSULATION TO BE INSTALLED TO RESNET GRADE 1 STANDARDS.Q. DUCTS, FLUES, SHAFTS, PLUMBING, PIPING, WIRING, EXHAUST FANS, & OTHER
PENETRATIONS TO UNCONDITIONED SPACE SEALED, WITH BLOCKING / FLASHING AS NECESSARY.
ROOF ASSEMBLY - NON RATED PRO-PANEL ROOFING PANEL ON OSB SHEATHING WITH WATER RESISTIVE UNDERLAYMENT ON 2x FRAMED ROOF TRUSS (REF. STRUCTURAL FOR TRUSS SIZE AND DETAILS) WITH R-38 GLASS FIBER BATT INSULATION (OR EQUIVALENT) AT TRUSS TOP CHORD AND 1/2" GYPSUM BOARD ON INTERIOR.
R1
ROOF TYPES
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING w/ 1x SUB-FRAMING/FURRING STRIP AT 16" ON CENTER, ON 1 1/2" RIGID INSULATION (R-7.5) ON BUILDING WRAP/ PAPER (SEAL ALL SEAMS) ON 7/16" OSB SHEATHING ON 2x6 STUDS AT 16" ON CENTER, WITH R-19 GLASS FIBER BATT INSULATION AND 1/2" GYPSUM BOARD ON INTERIOR.
W1
EXTERIOR WALL (LOAD-BEARING)FIBER CEMENT HORIZONTAL LAP SIDING, ON BUILDING WRAP/PAPER (SEALL ALL SEAMS) ON OSB SHEATHING ON 2x4 STUDS AT 16" O.C., WITH 1/2" GYPSUM BOARD ON INTR.TYPE W2A - SAME AS W2 EXCEPT NO GYPSUM BOARD
INTERIOR SEPARATION WALL - 1 HOUR FIRE RATING (LOAD-BEARING) - UL U340ONE LAYER 5/8" TYPE "X" GYPSUM BOARD ON 1/2" CLARK DIETRICH RC DELUXE RESILIENT CHANNEL (@ 24" O.C.) ONE SIDE ON 2x4 STUDS (@ 24" O.C.) STAGGERED ON 2x6 PLATES (STAGGERED @ 12" O.C.). UNFACED SOUND BATT INSULATION FULL DEPTH OF CAVITY WITH 5/8" TYPE "X" GYPSUM BOARD AT OPPOSITE SIDE.
D1
W2
EXTERIOR WALL TYPES
INTERIOR PARTITION WALL (NON-/LOAD BEARING) (1) LAYER(S) 1/2" GYPSUM BOARD (EACH SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 51B: SAME AS 51A EXCEPT 2x6 STUDSTYPE 52A: SAME AS 51A EXCEPT GYPSUM BOARD ONE SIDE ONLY.TYPE 52C: SAME AS 52A EXCEPT 2x2 STUDS
51A
INTERIOR WALL TYPES
52A
INTERIOR PARTITION WALL (NON-/LOAD BEARING) ONE LAYER(S) 1/2" GYPSUM BOARD (ONE SIDE) ON 2x4 STUDS AT 16" ON CENTER.TYPE 52B: SAME AS 52A EXCEPT 2x6 STUDS
FLOOR TYPES
FLOOR ASSEMBLY4" CONCRETE SLAB (PER STRUCTURAL) ON 15 MIL VAPOR BARRIER ON 4" COMPACTED GRAVEL BASE.NOTE: AT SLAB EDGE, PROVIDE 2'-0" MINIMUM (VERTICAL) 2" RIGID INSULATION.
F1
REFERENCE SHEET GI000
REFERENCE SHEET GI000
FLOOR ASSEMBLY3/4" PLYWOOD DECKING ON 2x6 FRAMING WITH 2X6 LEDGER BOARDS.
F2
REF: SCHED. REF: SCHED. EQEQ
REF: SCHED.
EXTERIOR DOORS INTERIOR DOORS
RE
F: S
CH
ED
.
RE
F: S
CH
ED
.
E1COMPOSITE CORE
E2COMPOSITE CORE w/ 1/4"TEMPERED GLASS LITE w/
MUNTINS BY MANUFACTURER
RE
F: S
CH
ED
.
REF: SCHED.
R1THREE-PANEL FLAT SLAB
READY-TO-FINISH
R2THREE-PANEL FLAT SLAB
READY-TO-FINISH
RE
F. S
CH
ED
.
R4FLUSH HOLLOW CORE WOOD
SLAB READY-TO-FINISH
R3FLUSH HOLLOW CORE WOOD
SLAB READY-TO-FINISH
RE
F. S
CH
ED
.
REF. SCHED.EQEQ
REF. SCHED.
RE
F. S
CH
ED
.
EXTERIOR FRAMES INTERIOR FRAMES
2" 2"REF: SCHED.
2"
RE
F: S
CH
ED
.
2" 2"
RE
F: S
CH
ED
.
REF: SCHED.
2"
2" 2"
2"
RE
F: S
CH
ED
.
REF: SCHED.
EF1 F1 F2
D3
AE
561
D2
AE561
D1
AE
561 E1
AE561
E2
AE
561 E1
AE561
E2
AE
561
3'-0" 2'-0"
5'-0"
4'-0" 3'-0"
7'-0"
5'-0
"1
'-8
"
5'-0
"1
'-8
"
4'-4
"2
'-4
"
1'-4
"5
'-4
"
4'-0"2'-6"
2'-0"
1'-10
"
AA
AA
A A
A
5'-0
"1
'-8
"
6'-8
"
6'-8
"
6'-8
"
6'-8
"
6'-8
"
3'-0"
2'-6"
2'-2
"1
'-11
"
C3
AE
561
C3
AE
561
C3
AE
561C
3
AE
561
C3
AE
561
3'-6"
C2
AE561
C2
AE561C2
AE561C2
AE561
C2
AE561
C1
AE
561 C1
AE
561 C1
AE
561 C1
AE
561 C
1
AE
561
A
VINYL w/ MULLEDFRAME, FIXED AT ONE SIDE,
SINGLE-HUNG (EGRESS COMPLIANT)AT ONE SIDE
B
VINYL w/ MULLEDFRAME, FIXED AT ONE SIDE,SINGLE-HUNG AT ONE SIDE
C
VINYL SINGLE-HUNG
D
VINYL SINGLE-HUNG(EGRESS COMPLIANT)
E
VINYL FIXED WITHTRANSLUCENT GLASS
AA
C3
AE
561
C2
AE561
C1
AE
561
A1
VINYL w/ MULLEDFRAME, FIXED AT ONE SIDE,
CASEMENT (ADA-ACCESSIBLECOMPLIANT) AT ONE SIDE
3'-0" 2'-0"
5'-0"
5'-0
"1
'-8
"
6'-8
" A
C3
AE
561
C2
AE561
C1
AE
561
D1
VINYL CASEMENT(ADA-ACCESSIBLE
COMPLIANT)
5'-0
"1
'-8
"
6'-8
"
3'-0"
2'-6"
2'-6"
2'-2
"1
'-11
"
A
C3
AE
561
C2
AE561
C1
AE
561
F
VINYL SINGLE-HUNG
4'-4
"2
'-4
"
2'-0"
6'-8
"
G
VINYL FIXED WITHTRANSLUCENT GLASS
A
1'-9"
1'-4
"5
'-4
" 6'-8
"C3
AE
561
C2
AE561
C1
AE
5612'-6"
4'-6
"
DOOR SHOE
THRESHOLD IN FULL BED OF SEALANT
03 3000.04CONCRETE SLAB ONGRADE
03 0516.01UNDER-SLAB VAPORRETARDER
SIDEWALK OR GRADE - SEE
CIVIL
4"
4"
MATERIAL: STAINLESS
STEEL
03 3000.08EXPANSION/ISOLATIONJOINT
07 6200.01METAL FLASHING
03 3000.19GRAVEL BASE
NOTE: POURABLE SEALANTAT ALL LOCATIONS WHERESLAB MEETS FOUNDATIONWALL OR WHERE SLAB ISPENETRATED.
ROOM SIDE
FLAT CASING W/ EASED EDGE, PAINTED SEALANT CONTINUOUS
AROUND FRAME, BOTH SIDES
DOOR AS SCHEDULED
WOOD DOOR FRAME, PAINTED
06 1000.10SHIM AS REQUIRED
DOOR STOP, PAINTED
51A 51B
FLAT CASING W/ EASED EDGE, PAINTED
DOOR AS SCHEDULED
SEALANT CONTINUOUS AROUND FRAME, BOTH
SIDES
WOOD DOOR FRAME, PAINTED
06 1000.10SHIM AS REQUIRED
06 1000.06WOOD HEADER, REF:
STRUCT. 51A 51B
EXTERIOR
INTERIORDOOR AS SCHEDULED
07 2500.01BUILDING WRAP/PAPER
07 9200.01BACKER ROD AND
SEALANT
4"
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
06 1000.10SHIM AS REQUIRED
W1AW2
07 4646.02FIBER CEMENT PLANK
07 4646.03FIBER CEMENT TRIM
07 9200.02SEALANT
07 4646.04STARTER STRIP
07 4646.05FURRING STRIP
07 4646.05FURRING STRIP
- AT DOORS/WINDOWS,SIZE = 5/4x4
09 2116.07CORNER BEAD
07 2500.03SADDLE FLASHING
07 2119FOAMED-IN-PLACEINSULATION
06 1000.06WOOD HEADER, REF:STRUCT.
07 2500.01BUILDING WRAP/PAPER
07 9200.01BACKER ROD AND
SEALANT
07 9200.01BACKER ROD ANDSEALANT
08 5313.01VINYL WINDOW AS
SCHEDULED
W1A
07 2500.02SELF-ADHERED FLEXIBLE
FLASHING
07 6200.01METAL FLASHING
07 4646.05FURRING STRIP
07 4646.04STARTER STRIP
07 4646.03FIBER CEMENT TRIM
- AT DOORS/WINDOWS,SIZE = 5/4x4
INTERIOREXTERIOR
07 2500.01BUILDING WRAP/PAPER
07 9200.01BACKER ROD AND
SEALANT
06 1000.10SHIM AS REQUIRED
06 1000.06WOOD HEADER, REF:STRUCT.
08 1416.01WOOD DOOR
08 1416.02WOOD CASING, PAINTED
W1AW2
07 2500.02SELF-ADHERED FLEXIBLE
FLASHING
07 2119FOAMED-IN-PLACEINSULATION07 6200.01
METAL FLASHING
07 4646.05FURRING STRIP
07 4646.04STARTER STRIP
07 4646.03FIBER CEMENT TRIM
- AT DOORS/WINDOWS,SIZE = 5/4x4
DOOR AS SCHEDULED
07 2500.01BUILDING WRAP/PAPER
09 2116.07CORNER BEAD
07 2500.02SELF-ADHERED FLEXIBLEFLASHING
07 6200.01METAL FLASHING 07 4646.02
FIBER CEMENT PLANK
07 2500.02SELF-ADHERED FLEXIBLE
FLASHING 07 4646.04STARTER STRIP
07 9200.01BACKER ROD AND
SEALANT
07 9200.01BACKER ROD ANDSEALANT
07 9200.02SEALANT
W1A
07 4646.03FIBER CEMENT TRIM
- AT DOORS/WINDOWS,SIZE = 5/4x4
07 2500.01BUILDING WRAP/PAPER
07 2500.02SELF-ADHERED FLEXIBLE
FLASHING
08 5313.01VINYL WINDOW AS
SCHEDULED
07 6200.01METAL FLASHING
07 9200.01BACKER ROD AND
SEALANT
07 9200.01BACKER ROD ANDSEALANT
07 4646.05FURRING STRIP
07 4646.03FIBER CEMENT TRIM
W1A
08 1416.02WOOD CASING, PAINTED
5 1
/2"
6"
- AT DOORS/WINDOWS,SIZE = 5/4x4
12"
WALL SHEATING
ATTACH 12" WIDE STRIP OF WEATHER
RESISTANT BARRIER TO FRONT FACE
OF SILL.
ATTACH 12" WIDE STRIP OF WEATHER
RESISTANT BARRIER TO FRONT FACE
OF JAMBS.
APPLY 6' FLASHING TAPE OVER SILL
AND JAMBS FOLDING A 2" RETURNS
INTO OPENINGS.
APPLY 4" PRE-FORMED SELF
ADHERING FLASHING CORNERS AT
JUNCTURES OF SILL TO JAMBS
CONTINUOUS BEAD OF SEALANT IS APPLIED
TO BACK OF WINDOW FLANGE. WINDOW IS
SHIMMED AND INSTALLED.
6” TAPE FLASHING IS INSTALLED OVER TOP
OF WINDOW FLANGE1 2 3 4 5 6
12"
16"
16"
12"
16"
16"
12"
16"
16"
12"
16"
16"
12"
16"
16"
WINDOW FLANGE
WINDOW WINDOW
WINDOW FLANGE
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
100% SUBMITTAL
12.10.2020
BID
PA
CK
AG
E #
4 -
TE
AC
HE
RA
GE
S
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
AE561
DOOR / WINDOW /FRAME TYPES,DETAILS ANDSCHEDULES
RW/JM
20-7002.005
AW
MARK DESCRIPTION
A 3/4" INSULATED TEMPERED GLASS
03 0516.01 UNDER-SLAB VAPOR RETARDER
03 3000.04 CONCRETE SLAB ON GRADE
03 3000.08 EXPANSION/ISOLATION JOINT
03 3000.19 GRAVEL BASE
06 1000.06 WOOD HEADER, REF: STRUCT.
06 1000.10 SHIM AS REQUIRED
07 2119 FOAMED-IN-PLACE INSULATION
07 2500.01 BUILDING WRAP/PAPER
07 2500.02 SELF-ADHERED FLEXIBLE FLASHING
07 2500.03 SADDLE FLASHING
07 4646.02 FIBER CEMENT PLANK
07 4646.03 FIBER CEMENT TRIM
07 4646.04 STARTER STRIP
07 4646.05 FURRING STRIP
07 6200.01 METAL FLASHING
07 9200.01 BACKER ROD AND SEALANT
07 9200.02 SEALANT
08 1416.01 WOOD DOOR
08 1416.02 WOOD CASING, PAINTED
08 5313.01 VINYL WINDOW AS SCHEDULED
09 2116.07 CORNER BEAD
1/4" = 1'-0"A3 DOOR TYPES1/4" = 1'-0"A1 DOOR FRAME TYPES
1/4" = 1'-0"B1 WINDOW TYPES
3" = 1'-0"D3 UNIT ENTRY DOOR THRESHOLD
3" = 1'-0"E1 DOOR JAMB @ INTERIOR WALL3" = 1'-0"E2 DOOR HEAD @ INTERIOR WALL
3" = 1'-0"D2 DOOR JAMB @ EXTERIOR WALL
3" = 1'-0"C1 WINDOW HEAD @ EXTERIOR WALL - VINYL
3" = 1'-0"D1 DOOR HEAD @ EXTERIOR WALL
3" = 1'-0"C2 WINDOW JAMB @ EXTERIOR WALL3" = 1'-0"C3 WINDOW SILL @ PLANK
DOOR AND FRAME SCHEDULE -- REFERENCE DETAILS THIS SHEET
NUMBER
DOOR FRAME
REMARKS
SIZE
TYPE MAT TYPE MATWIDTH HEIGHT THK
100 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
103 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
105 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
106 4' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
107 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
108 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
109 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
110 3' - 0" 6' - 8" 1 3/4" E1 HM EF1 WD
120 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
123 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
125 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
126 4' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
127 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
128 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
129 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
130 3' - 0" 6' - 8" 1 3/4" E1 COM EF1 WD
200 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
203 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
204 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
205 2' - 6" 6' - 8" 1 3/4" R4 WD F1 WD
206 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
207A 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
207B 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
209 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
210 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
211 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
212 3' - 0" 6' - 8" 1 3/4" E1 COM EF1 WD
220 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
223 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
224 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
225 2' - 6" 6' - 8" 1 3/4" R4 WD F1 WD
226 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
227A 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
227B 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
229 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
230 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
231 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
232 3' - 0" 6' - 8" 1 3/4" E1 COM EF1 WD
300 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
301 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
302 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
303 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
306 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
307 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
308 2' - 6" 6' - 8" 1 3/4" R1 WD F1 WD
309 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
310 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
312 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
313 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
314 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
315 3' - 0" 6' - 8" 1 3/4" E1 COM EF1 WD
A100 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
A103 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
A104 4' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A106 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
A107 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A108 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A109 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A110 3' - 0" 6' - 8" 1 3/4" E1 HM EF1 WD
A200 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
A203 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
A204 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
A205 2' - 10" 6' - 8" 1 3/4" R4 WD F1 WD
A206 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A207A 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A207B 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A209 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A210 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A211 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A212 3' - 0" 6' - 8" 1 3/4" E1 COM EF1 WD
A300 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
A301 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A302 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A303 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A306 3' - 0" 6' - 8" 1 3/4" E2 COM EF1 WD
A307 5' - 0" 4' - 8" 1 3/4" R3 WD F2 WD
A308 2' - 10" 6' - 8" 1 3/4" R1 WD F1 WD
A309 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A310 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A312 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A313 3' - 0" 6' - 8" 1 3/4" R1 WD F1 WD
A314 5' - 0" 6' - 8" 1 3/4" R2 WD F2 WD
A315 3' - 0" 6' - 8" 1 3/4" E1 COM EF1 WD
(PROVIDE HORIZONTAL SLAT LOUVER BLINDS)
1/16" = 1'-0"E5 WINDOW FLASHING DETAIL
13
13
13
13
13
13
13 01/06/21 ASI-001T
13 13
A. ALL PIPING AND DUCTS IN FINISHED ROOMS OR SPACES SHALL BE CONCEALED IN FURRED CHASES OR SUSPENDED CEILINGS, UNLESS OTHERWISE NOTED.
B. PROVIDE ACCESS PANELS OR DOORS IN INACCESSIBLE CEILINGS AND/OR CHASES FOR ALL VALVES, TRAPS, DAMPERS, CLEANOUTS, COILS, FANS, CONTROLS, ETC. THEY SHALL BE FURNISHED UNDER DIVISION 23 AND INSTALLED UNDER THE ARCHITECTURAL SPECIFICATION. ACCESS DOOR RATING SHALL MATCH CLASSIFICATION OF WALL AND CEILING FIRE RATING.
C. COORDINATE THE LOCATION OF ALL DIFFUSERS, GRILLES, REGISTERS, ACCESS DOORS, ETC., WITH THE ARCHITECTURAL REFLECTED CEILING PLAN(S).
D. ALL ROUND RUNOUTS AND DROPS TO DIFFUSERS SHALL BE THE SAME NOMINAL SIZE AS THE SCHEDULED DIFFUSER NECK SIZE.
E. THE FIRST FIGURE OF DUCT SIZE INDICATES DIMENSION OF FACE SHOWN OR INDICATED. ALL DUCT SIZES SHOWN ON DRAWINGS ARE NET INSIDE DIMENSIONS. PROVIDE ONE INCH ACOUSTICAL LINING (TYPE D3 INSULATION) IN LOW VELOCITY RECTANGULAR DUCTWORK FOR THE FIRST 10 DIAMETERS OF DUCTWORK CONNECTED TO DEVICE, OR AS INDICATED ON DRAWINGS, WHICHEVER IS GREATER. FOR THE REMAINDER OF THIS DUCTWORK PROVIDE AS INDICATED IN THE INSULATION SPECIFICATIONS.
D
NOTE: NOT ALL ABBREVIATIONS ORSYMBOLS APPLY TO THIS PROJECT
RS
RL
R
T
XX-##
REFRIGERATION
REFRIGERATION LIQUID
REFRIGERATION SUCTION
MECHANICAL PIPING
DIRECTION OF FLOW
DRAIN
CONDENSATE DRAINCD
DIRECTION PITCHDOWN
M301
A1
SCALE
DETAIL
SCALE
SECTIONA1
A1
X#/X###
MECHANICAL SYMBOL LEGEND
DUCT TRANSITION
SUPPLY DUCT
RISE IN DUCT
INDICATES A 12" ROUND DUCT
ACCESS DOOR
INDICATES A 24"x12" RECTANGULAR DUCT (WIDTH x DEPTH)
DUCTWORK SYMBOLS
SEE CONTROL DRAWINGS FOR TYPEROOM THERMOSTAT/TEMP. TRANSMITTER LOCATION ONLY LETTERS REFER TO THE EQUIPMENT TYPE
EQUIPMENT SYMBOLS
NUMBERS REFER TO SPECIFIC EQUIPMENT
DRAWING NUMBER WHERE DETAILED
SECTION LOCATION
DRAWING NUMBER WHERE DETAILED
DETAIL LOCATION
SECTION LETTER LOCATION
SECTION SYMBOL
DETAIL SYMBOL
SECTION AND DETAIL TITLES
DETAIL NUMBER LOCATION
SYMBOL INDICATES EQUIPMENT IDENTIFIEDIN EQUIPMENT SCHEDULE
XX-#
CFM###
SYMBOL INDICATES GRILLE OR DIFFUSERIDENTIFIED IN EQUIPMENT SCHEDULE
CEILING EXHAUST REGISTER
PIPING SYMBOLS
GENERAL NOTES
EXHAUST DUCT
ABBREVIATIONS
AHU AIR HANDLING UNIT
BRAKE HORSEPOWER
BTU PER HOUR
BRITISH THERMAL UNIT
BOTTOM OF DUCT
BOTTOM OF PIPE
ACOUSTIC LINING
ABOVE FINISHED FLOOR
ACCESS DOOR
COMPRESSED AIR
DRAIN
ENTERING
EXHAUST
CONTINUATION
DIRECT EXPANSION
CUBIC FEET PER MINUTE
CONDENSATE DRAIN
AL
AFF
AD
BHP
BOD
BTU
BOP
CA
CFM
D
DX
ENT
EXH
CD
EMCS
CONT.
BTUH
FLEXIBLE
FLAT BOTTOM
FILTER GAUGE
FLOOR SINK
FLOOR DRAIN
FAN COIL UNIT
DEGREES FAHRENHEIT
FEET PER MINUTE
FEET
FLAT TOP
HOSE BIBB
INCHES
GALLONS PER MINUTE
GALLONS PER HOUR
FB
°F
FD
FCU
F.G.
FS
FPM
FT.
FT
GPM
GPH
HB
HD
IN
HEPA
FLEX
KILOWATT
MAIN AIR (CONTROLS)
KILOWATT HOUR
OPPOSED BLADE DAMPER
OUTSIDE AIR
NUMBER (QUANTITY)
NOT IN CONTRACT
NOT APPLICABLE
MOTOR CONTROL CENTER
QUANTITY
QUADRANT
REVOLUTIONS PER MINUTE
RELATIVE HUMIDITY
SMOKE CONTROL DAMPER
RETURN AIR
PRESSURE REDUCING VALVE
KW
KWH
MA
MCC
NO.
NIC
OBD
OA
NA
PRV
PSIG
QTY
Rh
R.A.
RPM
SCD
QUAD
ENERGY MANAGEMENT CONTROL SYSTEM
HIGH EFFICIENCY PARTICULATE AIR (FILTER)
HAND DAMPER (VOLUME DAMPER)
POUNDS PER SQUARE INCH GAGE
TYPICAL
VOLTS
SOUND TRAP
VARIABLE AIR VOLUME
TOP OF PIPE TRAPEZE
VENT THRU ROOF
VELOCITY
ST
SP
TYP.
VAC
VAV
V
TP
VTR
VEL
SDVV
TOPT
SINGLE DUCT VARIABLE VOLUME
STATIC PRESSURE (INCHES OF WATER)
TOTAL PRESSURE (INCHES OF WATER)
VOLTS, ALTERNATING CURRENT
ACU AIR CONDITIONING UNIT
##x##
SIDEWALL GRILLE DIMENSION WHERESHOWN ON PLANS
FLEXIBLE CONNECTION
STANDARD LONG RADIUS ELBOW
VANED ELBOW (PROVIDE ALL SQUARE ORRECTANGULAR ELBOWS WITH VANESEXCEPT TRANSFER AIR SOUND ELBOW)
SHORT RADIUS ELBOW (PROVIDE ALLSQUARE OR RECTANGULAR ELBOWS WITHVANES EXCEPT TRANSFER AIR SOUNDELBOW)
24x12
12Ø
F. PROVIDE TURNING VANES IN ALL SQUARE ELBOWS, EXCEPT TRANSFER AIR SOUND ELBOWS.
G. REFER TO THE ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE RATED AND/OR SMOKE RATED WALLS AND ASSEMBLIES. PROVIDE APPROVED FIRE DAMPERS IN ALL REQUIRED PENETRATIONS FOR DUCTWORK, GRILLES, REGISTERS AND DIFFUSERS. ALL PIPE AND DUCTWORK PENETRATIONS OF FIRE, SMOKE AND FULL HEIGHT WALLS SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. APPROVED FIRE PROOF CAULKING MATERIAL.
H. CONTRACTOR SHALL COORDINATE ALL DUCTWORK, PIPING, PLUMBING AND FIRE PROTECTION PIPING WITH STRUCTURAL AND ELECTRICAL SYSTEMS AND SHALL PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY.
I. CONTRACTOR SHALL FURNISH ALL NECESSARY STRUCTURES, INSERTS, SLEEVES, AND HANGING DEVICES FOR INSTALLATION OF MECHANICAL AND PLUMBING EQUIPMENT, DUCTWORK AND PIPING, ETC. CONTRACTOR SHALL COORDINATE WITH GENERAL CONTRACTOR AND ALL BUILDING TRADES TO AVOID CONFLICTS AND TO MAINTAIN EQUIPMENT ACCESS AND SERVICEABILITY.
J. CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL NECESSARY MISCELLANEOUS ANGLES, CHANNELS, UNISTRUT, ETC., AS MAY BE REQUIRED TO ADEQUATELY SUPPORT THE MECHANICAL PIPING, DUCTWORK, AND EQUIPMENT IN A MANNER APPROVED BY THE ARCHITECT, WHICH WILL NOT OVERLOAD THE BUILDING STRUCTURAL SYSTEM.
K. SEAL ALL TRANSVERSE JOINTS, LONGITUDINAL SEAMS, DUCT WALL PENETRATIONS AND FITTING CONNECTIONS ON ALL DUCT SYSTEMS.
L. MECHANICAL ITEMS SUCH AS ROOF DRAINS, FLOOR DRAINS, PLUMBING FIXTURES, ETC. SHOWN ON THE ARCHITECTURAL DRAWINGS BUT NOT SHOWN ON THE MECHANICAL DRAWINGS SHALL BE INCLUDED IN THE PROJECT. THESE ITEMS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT FOR INCLUSION IN ADDENDUM.
CO CARBON DIOXIDE MONITOR LOCATION ONLY TO BE HARDWIRED AND HAVE BATTERY BACKUP2
D
GE
R
REENIGNELANOISSEFORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 1
:36
:32
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
M-001
MECHANICALLEGEND
AS
20-7002.005
RKS
13
13 01-06-21 ADD-001T
RSRLRSRL
BATH
107
BATH
127KITCHEN
101 KITCHEN
121
LAUNDRY
124
HALL
125
LIVING/DINING
120
BEDROOM
128
BEDROOM
108
LIVING/DINING
100
LAUNDRY
104
HALL
105
CU-1
MECH.
103
CU-2
HP-2
8x4
12x12
10x10
12x6
12x12
HP-1
1
M-501
CEF-10
CEF-8 CEF-9CEF-11
20x14800
RG-120x14800
RG-1
CEF-15
CEF-16
14x6
10x6
8x4
14x6
10x10
12x6
10x68x4
8x4
8x8180
SD-1
10x10250
SD-1
6x650
SD-1
12x12280
SD-112x12280
SD-1
6x650
SD-16x650
SD-1
8x8180
SD-1
6x650
SD-1
10x10250
SD-1
4ø
6ø
6ø
6ø6ø6ø
6ø
7ø
1
M-501
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 3
:47
:48
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
MH101
HVAC PLAN -1BD/1BA DUPLEX
AS
20-7002.005
RKS/ZH
1/4" = 1'-0"A5 HVAC PLAN - 1BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
1. INDOOR VERTICAL SPLIT SYSTEM MOUNTED 24" HIGH ANGLE IRON STAND WITH A HEAVY GAUGE SHEET METAL INTAKE PLENUM. SEE PIPE DIAGRAM E2/M-501. DUCT DISCHARGE FROM TOP OF UNIT BETWEEN TRUSSES.
2. 6" DIAMETER EXHAUST UP BETWEEN TRUSS THROUGH 8" ROOF CURB TO GOOSENECK. SEE DETAIL E2/M-501. COORDINATE LOCATION WITH TRUSS SPACING. COORDINATE LOCATION OF FAN BETWEEN TRUSSES. WALL MOUNTED FAN SWITCH WITH VENILATION CONTROL & DELAY TIMER TO BE PROVIDE BY DIVISTION 23 AND INSTALLED UNDER DIVISION 26. SEE CONTROL DIAGRAM AND VENTILATION CALCULATION ON SHEET MI601.
3. 4" DRYER VENT THROUGH WALL TO LOUVERED HOOD LOCATED AT 24" AFF.
4. OUTDOOR HEAT PUMP MOUNTED ON CONCRETE PAD. SEE PIPE DIAGRAM E2/M-501.
5. 7" DIAMETER EXHAUST FROM RANGE HOOD UP THROUGH ROOF CURB TO GOOSENECK. SEE DETAIL E4/M-501. COORDINATE LOCATION WITH TRUSS SPACING.
6. 6" DIAMETER EXHAUST UP BETWEEN TRUSS THROUGH 8" HIGH ROOF CURB TO GOOSENECK. SEE DETAIL E4/M-501. COORDINATE LOCATION WITH TRUSS SPACING. COORDINATE LOCATION OF FAN BETWEEN TRUSSES. SEE CONTROL DIAGRAMS.
A. FOR INFORMATION ON LOW PRESSURE DUCT FITTINGS, SEE DETAIL C5/M-501.
B. ALL OVERHEAD EQUIPMENT, PIPING AND DUCTWORK, IS TO BE SUSPENDED FROM STRUCTURAL MEMBERS.
C. PROVIDE REMOTE ACCESS PROGRAMABLE THERMOSTATS FOR EACH HEAT PUMP.
D. SEE SITE PLAN FOR PLAN ORIENTATION.
E. PROVIDE CO MONITORS FOR EACH UNIT, HARD-WIRED WITH BATTERY BACKUP.
F. SEAL ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, AND ENTRY POINTS WITH APPROPRIATE CAULKING AND INSTALL RODENT-PROOF SCREENS ON ALL OPENINGS GREATER THAN 1/4"
G. PROVIDE DRAIN PAN AND ASSOCIATED PIPING TO FLOOR SINK FOR LEED/ENERGY STAR V3 PURPOSES.
1/4" = 1'-0"C5 MECHANICAL ROOF PLAN - 1BD/1BA DUPLEX
33
4 4
1
1
22 2
2
0' 2' 4' 8'
0' 2' 4' 8'
6 2 2
6
5
5
5
5
2
2
6
2
6
13
13
13 13
13 01-06-21 ADD-001T
RS RL
2
M-501
KITCHEN
201
BEDROOM
206
BEDROOM
226
BATH
229
BATH
209
MECH.
204
LIVING/DINING
200
BEDROOM
210
BEDROOM
230
LIVING/DINING
220
MECH.
224
MUD/LAUNDRY
223
KITCHEN
221
CU-3 CU-4
HP-4
HP-3
14x12
8x4
12x6
10x10
10x8
14x12
10x10
8x4
8x4
CEF-6
CEF-4
CEF-5
CEF-7
CEF-13
CEF-14
RLRS
30x121000
RG-1
30x121000
RG-1
10x10
10x6
14x6
10x10
10x6
14x68x4
12x6
10x8
10x6 10x6
8x8180
SD-1
12x12300
SD-1
6x650
SD-1
8x8170
SD-1
6x650
SD-1
10x10250
SD-110x10250
SD-1
6x650
SD-1
8x8170
SD-1
12x12300
SD-1
8x8180
SD-1
6x650
SD-1
7ø
6ø
4ø
6ø
6ø 6ø
4ø
6ø
7ø
MUD/LAUNDRY
203
2
M-501
D
GE
R
)L
ACI
RT
CE
L(
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
E
38934JOHN M.
MONTANO
EXPIRES 03/31/2021
~
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 5
:22
:29
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
MH102
HVAC PLAN -2BD/1BA DUPLEX
AS
20-7002.005
RKS/ZH
1/4" = 1'-0"A5 HVAC PLAN - 2BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
A. FOR INFORMATION ON LOW PRESSURE DUCT FITTINGS, SEE DETAIL C5/M-501.
B. ALL OVERHEAD EQUIPMENT, PIPING AND DUCTWORK, IS TO BE SUSPENDED FROM STRUCTURAL MEMBERS.
C. PROVIDE REMOTE ACCESS PROGRAMABLE THERMOSTATS FOR EACH HEAT PUMP.
D. SEE SITE PLAN FOR PLAN ORIENTATION.
E. PROVIDE CO MONITORS FOR EACH UNIT, HARD-WIRED WITH BATTERY BACKUP.
F. SEAL ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, AND ENTRY POINTS WITH APPROPRIATE CAULKING AND INSTALL RODENT-PROOF SCREENS ON ALL OPENINGS GREATER THAN 1/4".
G. PROVIDE DRAIN PAN AND ASSOCIATED PIPING TO FLOOR SINK FOR LEED/ENERGY STAR V3 PURPOSES
1/4" = 1'-0"C5 MECHANICAL ROOF PLAN - 2BD/1BA DUPLEX
33
4 4
1
1
2
2 2
2
0' 2' 4' 8'
0' 2' 4' 8'
6
2 2
6
1. INDOOR VERTICAL SPLIT SYSTEM MOUNTED 24" HIGH ANGLE IRON STAND WITH A HEAVY GAUGE SHEET METAL INTAKE PLENUM. SEE PIPE DIAGRAM E2/M-501. DUCT DISCHARGE FROM TOP OF UNIT BETWEEN TRUSSES.
2. 6" DIAMETER EXHAUST UP BETWEEN TRUSS THROUGH 8" ROOF CURB TO GOOSENECK. SEE DETAIL E2/M-501. COORDINATE LOCATION WITH TRUSS SPACING. COORDINATE LOCATION OF FAN BETWEEN TRUSSES. WALL MOUNTED FAN SWITCH WITH VENILATION CONTROL & DELAY TIMER TO BE PROVIDE BY DIVISTION 23 AND INSTALLED UNDER DIVISION 26. SEE CONTROL DIAGRAM AND VENTILATION CALCULATION ON SHEET MI601.
3. 4" DRYER VENT THROUGH WALL TO LOUVERED HOOD LOCATED AT 24" AFF.
4. OUTDOOR HEAT PUMP MOUNTED ON CONCRETE PAD. SEE PIPE DIAGRAM E2/M-501.
5. 7" DIAMETER EXHAUST FROM RANGE HOOD UP THROUGH ROOF CURB TO GOOSENECK. SEE DETAIL E4/M-501. COORDINATE LOCATION WITH TRUSS SPACING.
6. 6" DIAMETER EXHAUST UP BETWEEN TRUSS THROUGH 8" HIGH ROOF CURB TO GOOSENECK. SEE DETAIL E4/M-501. COORDINATE LOCATION WITH TRUSS SPACING. COORDINATE LOCATION OF FAN BETWEEN TRUSSES. SEE CONTROL DIAGRAMS.
5
5
5
5
6
6
2
2
1313
13 01-06-21 ADD-001T
13
12x10
14x20
3
M-501
BATH
303
KITCHEN
304
BEDROOM
302
LIVING/DINING
300
BEDROOM
313
BATH
312
BEDROOM
310
MUD/LAUNDRY
306
MECH.
307
CU-5
HP-5
10x10
CEF-1
CEF-3
CEF-2
36x121200
RG-1
CEF-12
8x4
10x6
10x10240
SD-1
8x4
12x6
12x6
10x8
12x6
6x650
SD-1
10x10210
SD-1
6x650
SD-1
8x8210
SD-1
8x8170
SD-1
10x6
10x10220
SD-1
6x650
SD-1
8x4
6ø 7ø
6ø
6ø
6ø
3
M-501
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 3
:50
:34
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
MH103
HVAC PLAN -3BD/2BASINGLE-FAMILY
AS
20-7002.005
RKS/ZH
1/4" = 1'-0"A5 HVAC PLAN - 3BD/2BA SINGLE-FAMILY
GENERAL SHEET NOTES
SHEET KEYNOTES
A. FOR INFORMATION ON LOW PRESSURE DUCT FITTINGS, SEE DETAIL C5/M-501.
B. ALL OVERHEAD EQUIPMENT, PIPING AND DUCTWORK, IS TO BE SUSPENDED FROM STRUCTURAL MEMBERS.
C. PROVIDE REMOTE ACCESS PROGRAMABLE THERMOSTATS FOR EACH HEAT PUMP.
D. SEE SITE PLAN FOR PLAN ORIENTATION.
E. PROVIDE CO MONITORS FOR EACH UNIT, HARD-WIRED WITH BATTERY BACKUP.
F. SEAL ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, AND ENTRY POINTS WITH APPROPRIATE CAULKING AND INSTALL RODENT-PROOF SCREENS ON ALL OPENINGS GREATER THAN 1/4".
G. PROVIDE DRAIN PAN AND ASSOCIATED PIPING TO FLOOR SINK FOR LEED/ENERGY STAR V3 PURPOSES
1/4" = 1'-0"C5 MECHANICAL ROOF PLAN - 3BD/2BA SINGLE-FAMILY
3
4
1
2
6
2
0' 2' 4' 8'
0' 2' 4' 8'
2
2
2
1. INDOOR VERTICAL SPLIT SYSTEM MOUNTED 24" HIGH ANGLE IRON STAND WITH A HEAVY GAUGE SHEET METAL INTAKE PLENUM. SEE PIPE DIAGRAM E2/M-501. DUCT DISCHARGE FROM TOP OF UNIT BETWEEN TRUSSES.
2. 6" DIAMETER EXHAUST UP BETWEEN TRUSS THROUGH 8" ROOF CURB TO GOOSENECK. SEE DETAIL E2/M-501. COORDINATE LOCATION WITH TRUSS SPACING. COORDINATE LOCATION OF FAN BETWEEN TRUSSES. WALL MOUNTED FAN SWITCH WITH VENILATION CONTROL & DELAY TIMER TO BE PROVIDE BY DIVISTION 23 AND INSTALLED UNDER DIVISION 26. SEE CONTROL DIAGRAM AND VENTILATION CALCULATION ON SHEET MI601.
3. 4" DRYER VENT THROUGH WALL TO LOUVERED HOOD LOCATED AT 24" AFF.
4. OUTDOOR HEAT PUMP MOUNTED ON CONCRETE PAD. SEE PIPE DIAGRAM E2/M-501.
5. 7" DIAMETER EXHAUST FROM RANGE HOOD UP THROUGH ROOF CURB TO GOOSENECK. SEE DETAIL E4/M-501. COORDINATE LOCATION WITH TRUSS SPACING.
6. 6" DIAMETER EXHAUST UP BETWEEN TRUSS THROUGH 8" HIGH ROOF CURB TO GOOSENECK. SEE DETAIL E4/M-501. COORDINATE LOCATION WITH TRUSS SPACING. COORDINATE LOCATION OF FAN BETWEEN TRUSSES. SEE CONTROL DIAGRAMS.
5
5
6
2
13
13
13
13
13 01-06-21 ADD-001T
LIVING/DINING
100
BEDROOM
108
BEDROOM
128
LIVING/DINING
120
KITCHEN
121
LAUNDRY
124
?
?
BATH
127BATH
107
?
?
LAUNDRY
104
CLOSET
109
CLOSET
129
KITCHEN
101
HALL
105
HALL
125
P1b
P7b P7b
P3b P3b
P12
P4P4
4"DCOTG
4"
SA
N
WCO(TYP)
WCO(TYP)
WCO(TYP) 3" VTR
3" VTR
2" V
2"
V
4" SAN 4" SAN
2" V
4" SAN
2"
V4" SAN4" SAN
4" SAN
4"
SA
N
4" SAN
WCOWCO
3 3
3 WCO
44
1
44
4
45 5
TO CIVIL
6" V-RG
2"FS1 2"FS1
6" V-RG
RADON GAS SUCTION PIT
RADON GAS SUCTION PIT
6
6
7
7
44
2" V 2" V
2"
SA
N
2"
SA
N
P12
3" VTR 3" VTR
6" V-RG
6" V-RG
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/6
/20
21 7
:54
:39
AM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
PL101
WASTE & VENTPLAN - 1BD/1BADUPLEX
AS
20-7002.005
JRS/AGS
1/4" = 1'-0"A5 WASTE & VENT PLAN - 1BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
1. INSTALL DOUBLE CLEANOUT TO GRADE IN ACCORDANCE WITH DETAIL A5/P-501.2. INSTALL 2" FLOOR SINK IN ACCORDANCE WITH DETAIL C3/P-501.3. INSTALL WALL CLEANOUT IN ACCORDANCE WITH DETAIL A2/P-501.4. 2" SAN PIPING DOWN TO FLOOR BELOW. 2" VENT PIPING UP TO CEILING ABOVE.5. 4" SAN PIPING DOWN TO FLOOR BELOW. 2" VENT PIPING UP TO CEILING ABOVE.6. DRAIN PAN TO DRAIN OVER TO FLOOR SINK BELOW MECHANICAL PLATFORM.7. 6" V-RG PIPING TO RISE UP FROM RADON PIT AND EXTEND BELOW SLAB.
A. AREFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT LOCATION AND HEIGHTS OF ALL PLUMBING FIXTURES BEFORE ROUGH-IN OR INSTALLATION OF PIPE. PLUMBING FIXTURES SHALL BE MOUNTED AT HEIGHTS SHOWN ON ARCHITECTURAL ELEVATION DRAWINGS.
B. ALL PIPING IN FINISHED ROOMS SHALL BE CONCEALED IN FURRED CHASES UNLESS OTHERWISE NOTED ON THIS DRAWING.
C. PROVIDE HINGED ACCESS DOORS FOR VALVES, WATER HAMMER ARRESTERS, ISOLATION BALL VALVES LOCATED IN NONACCESSIBLE CEILINGS AND CHASES. DOORS FURNISHED PER ARCHITECTURAL SPECIFICATIONS AND PURCHASED AND INSTALLED PER DIVISION 22. ACCESS DOOR RATING SHALL MATCH THE CLASSIFICATION OF WALLS AND CEILING FIRE RATING. COORDINATE COLOR AND TYPE OF ACCESS DOOR WITH ARCHITECTURAL PRIOR TO PERFORMING WORK.
D. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE RATED AND OR SMOKE RATED WALLS AND ASSEMBLIES. PIPING PENETRATIONS OF FIRE AND SMOKE RATED WALLS AND LISTED ASSEMBLIES SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. LISTED FIRE PROOF CAULKING MATERIAL.
E. COORDINATE ALL PLUMBING PIPING WITH ALL OTHER TRADES AND PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
F. PIPING LOCATIONS HAVE BEEN SHOWN FOR CLARITY AND DO NOT NECESSARILY REFLECT THE EXACT LOCATION OF PIPE. COORDINATE ROUTING WITH ALL OTHER TRADES BEFORE INSTALLATION OR MAKEUP OF PIPE. PROVIDE COORDINATION DRAWINGS PER SPECIFICATIONS.
G. REFER TO DRAWING P-701 FOR PLUMBING ROUGH IN REQUIREMENTS.H. SEAL ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, AND ENTRY
POINTS WITH APPROPRIATE CAULKING AND INSTALL RODENT-PROOF SCREENS ON ALL OPENINGS GREATER THAN 1/4".
I. PROVIDE DRAIN PAN AND ASSOCIATED PIPING TO FLOOR SINK FOR LEED/ENERGY STAR V3 PURPOSES
J. FOR RADON GAS SUCTION PUT DETAILS, SEE ARCHITECURAL PLANS.
1/4" = 1'-0"C5 PLUMBING ROOF PLAN - 1BD/1BA DUPLEX
0' 2' 4' 8'
0' 2' 4' 8'
13
13 01-06-21 ADD-001T
LIVING/DINING
200
BEDROOM
206
MECH.
204
KITCHEN
201
BEDROOM
210
BATH
209
BATH
229
BEDROOM
230
LIVING/DINING
220
BEDROOM
226
MUD/LAUNDRY
223
MECH.
224
CLOSET
207 KITCHEN
221
P12
P4
P3bP3bP1b P1b
P7bP7b
P4
P12
4"
SA
N
4"DCOTG
WCO(TYP)
WCO(TYP)
WCO(TYP)
4" SAN 4" SAN
2" V 2" V
2"
V
2"
V
4" SAN
3" VTR
WCOWCO
WCO
1
33
3
22
4 4
44
5
5
6" V-RG6" V-RG
66
2"FS12"FS1
3" VTR
RADON GAS SUCTION PIT
RADON GAS SUCTION PIT
2" V 2" V
2" V2" V 7 7
4 4
2" V
2" V
3" VTR 3" VTR
6" V-RG6" V-RG
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/6
/20
21 8
:22
:16
AM
D:\R
evit 2
020
\Pro
jects
\81
83_
ME
P_
Lu
kach
ukai S
ch
oo
l -
Te
ach
era
ges_
AG
Sob
ers
.rvt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
PL102
WASTE & VENTPLAN - 2BD/1BADUPLEX
AS
20-7002.005
JRS/AGS
1/4" = 1'-0"A5 WASTE & VENT PLAN - 2BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
1/4" = 1'-0"C5 PLUMBING ROOF PLAN - 2BD/1BA DUPLEX
1. INSTALL DOUBLE CLEANOUT TO GRADE IN ACCORDANCE WITH DETAIL A5/P-501.2. INSTALL 2" FLOOR SINK IN ACCORDANCE WITH DETAIL C3/P-501.3. INSTALL WALL CLEANOUT IN ACCORDANCE WITH DETAIL A2/P-501.4. 2" SAN PIPING DOWN TO FLOOR BELOW. 2" VENT PIPING UP TO CEILING ABOVE.5. 4" SAN PIPING DOWN TO FLOOR BELOW. 2" VENT PIPING UP TO CEILING ABOVE.6. DRAIN PAN TO DRAIN OVER TO FLOOR SINK BELOW MECHANICAL PLATFORM.7. 6" V-RG PIPING TO RISE UP FROM RADON PIT AND EXTEND BELOW SLAB.
A. AREFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT LOCATION AND HEIGHTS OF ALL PLUMBING FIXTURES BEFORE ROUGH-IN OR INSTALLATION OF PIPE. PLUMBING FIXTURES SHALL BE MOUNTED AT HEIGHTS SHOWN ON ARCHITECTURAL ELEVATION DRAWINGS.
B. ALL PIPING IN FINISHED ROOMS SHALL BE CONCEALED IN FURRED CHASES UNLESS OTHERWISE NOTED ON THIS DRAWING.
C. PROVIDE HINGED ACCESS DOORS FOR VALVES, WATER HAMMER ARRESTERS, ISOLATION BALL VALVES LOCATED IN NONACCESSIBLE CEILINGS AND CHASES. DOORS FURNISHED PER ARCHITECTURAL SPECIFICATIONS AND PURCHASED AND INSTALLED PER DIVISION 22. ACCESS DOOR RATING SHALL MATCH THE CLASSIFICATION OF WALLS AND CEILING FIRE RATING. COORDINATE COLOR AND TYPE OF ACCESS DOOR WITH ARCHITECTURAL PRIOR TO PERFORMING WORK.
D. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE RATED AND OR SMOKE RATED WALLS AND ASSEMBLIES. PIPING PENETRATIONS OF FIRE AND SMOKE RATED WALLS AND LISTED ASSEMBLIES SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. LISTED FIRE PROOF CAULKING MATERIAL.
E. COORDINATE ALL PLUMBING PIPING WITH ALL OTHER TRADES AND PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
F. PIPING LOCATIONS HAVE BEEN SHOWN FOR CLARITY AND DO NOT NECESSARILY REFLECT THE EXACT LOCATION OF PIPE. COORDINATE ROUTING WITH ALL OTHER TRADES BEFORE INSTALLATION OR MAKEUP OF PIPE. PROVIDE COORDINATION DRAWINGS PER SPECIFICATIONS.
G. REFER TO DRAWING P-701 FOR PLUMBING ROUGH IN REQUIREMENTS.H. SEAL ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, AND ENTRY
POINTS WITH APPROPRIATE CAULKING AND INSTALL RODENT-PROOF SCREENS ON ALL OPENINGS GREATER THAN 1/4".
I. PROVIDE DRAIN PAN AND ASSOCIATED PIPING TO FLOOR SINK FOR LEED/ENERGY STAR V3 PURPOSES
J. FOR RADON GAS SUCTION PUT DETAILS, SEE ARCHITECURAL PLANS.
0' 2' 4' 8'
0' 2' 4' 8'
13 01-06-21 ADD-001T
13
BEDROOM
302
LIVING/DINING
300
BEDROOM
313
BATH
312
BEDROOM
310
?
?
COAT
308
KITCHEN
304MUD/LAUNDRY
306
P12
P4
P3b
P1b
P7b
P3bP3b
P7b
P1b
4"DCOTG
4"
SA
N
4" SAN
WCO(TYP)
WCO(TYP)
4"
SA
N4" SAN 4" SAN 4
" S
AN
2"
SA
N
4" SAN
2"
SA
N
2"
SA
N
3" VTR
2" V
2"
V
2" V
2"
V
2"
V
2" V
2"
V
2" V
2"
V
2
3
1
3
3
4
4 5
5
6
RADON GAS SUCTION PIT
2" V
2" V
7
2" V
4
4
4
6" V-RG
2" V
2" V
3" VTRR 25' - 0"
R 10' - 0"
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/6
/20
21 7
:53
:56
AM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
PL103
WASTE & VENTPLAN - 3BD/2BASINGLE-FAMILY
AS
20-7002.005
JRS/AGS
1/4" = 1'-0"A5 WASTE & VENT PLAN - 3BD/2BA SINGLE-FAMILY
GENERAL SHEET NOTES
SHEET KEYNOTES
1/4" = 1'-0"C5 PLUMBING ROOF PLAN - 3BD/2BA SINGLE-FAMILY
1. INSTALL DOUBLE CLEANOUT TO GRADE IN ACCORDANCE WITH DETAIL A5/P-501.2. INSTALL 2" FLOOR SINK IN ACCORDANCE WITH DETAIL C3/P-501.3. INSTALL WALL CLEANOUT IN ACCORDANCE WITH DETAIL A2/P-501.4. 2" SAN PIPING DOWN TO FLOOR BELOW. 2" VENT PIPING UP TO CEILING ABOVE.5. 4" SAN PIPING DOWN TO FLOOR BELOW. 2" VENT PIPING UP TO CEILING ABOVE.6. DRAIN PAN TO DRAIN OVER TO FLOOR SINK BELOW MECHANICAL PLATFORM.7. 6" V-RG PIPING TO RISE UP FROM RADON PIT AND EXTEND BELOW SLAB.
A. AREFER TO ARCHITECTURAL FLOOR PLANS FOR EXACT LOCATION AND HEIGHTS OF ALL PLUMBING FIXTURES BEFORE ROUGH-IN OR INSTALLATION OF PIPE. PLUMBING FIXTURES SHALL BE MOUNTED AT HEIGHTS SHOWN ON ARCHITECTURAL ELEVATION DRAWINGS.
B. ALL PIPING IN FINISHED ROOMS SHALL BE CONCEALED IN FURRED CHASES UNLESS OTHERWISE NOTED ON THIS DRAWING.
C. PROVIDE HINGED ACCESS DOORS FOR VALVES, WATER HAMMER ARRESTERS, ISOLATION BALL VALVES LOCATED IN NONACCESSIBLE CEILINGS AND CHASES. DOORS FURNISHED PER ARCHITECTURAL SPECIFICATIONS AND PURCHASED AND INSTALLED PER DIVISION 22. ACCESS DOOR RATING SHALL MATCH THE CLASSIFICATION OF WALLS AND CEILING FIRE RATING. COORDINATE COLOR AND TYPE OF ACCESS DOOR WITH ARCHITECTURAL PRIOR TO PERFORMING WORK.
D. REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF ALL FIRE RATED AND OR SMOKE RATED WALLS AND ASSEMBLIES. PIPING PENETRATIONS OF FIRE AND SMOKE RATED WALLS AND LISTED ASSEMBLIES SHALL BE CAULKED AIRTIGHT TO THE ADJACENT STRUCTURE BY MEANS OF U.L. LISTED FIRE PROOF CAULKING MATERIAL.
E. COORDINATE ALL PLUMBING PIPING WITH ALL OTHER TRADES AND PROVIDE NECESSARY OFFSETS TO AVOID CONFLICTS AND TO MAINTAIN REQUIRED EQUIPMENT ACCESS AND SERVICEABILITY.
F. PIPING LOCATIONS HAVE BEEN SHOWN FOR CLARITY AND DO NOT NECESSARILY REFLECT THE EXACT LOCATION OF PIPE. COORDINATE ROUTING WITH ALL OTHER TRADES BEFORE INSTALLATION OR MAKEUP OF PIPE. PROVIDE COORDINATION DRAWINGS PER SPECIFICATIONS.
G. REFER TO DRAWING P-701 FOR PLUMBING ROUGH IN REQUIREMENTS.H. SEAL ALL EXTERNAL CRACKS, JOINTS, PENETRATIONS, EDGES, AND ENTRY
POINTS WITH APPROPRIATE CAULKING AND INSTALL RODENT-PROOF SCREENS ON ALL OPENINGS GREATER THAN 1/4".
I. PROVIDE DRAIN PAN AND ASSOCIATED PIPING TO FLOOR SINK FOR LEED/ENERGY STAR V3 PURPOSES
J. FOR RADON GAS SUCTION PUT DETAILS, SEE ARCHITECURAL PLANS.
0' 2' 4' 8'
0' 2' 4' 8'
13
13 01-06-21 ADD-001T
LIVING/DINING
100
BEDROOM
108
BEDROOM
128
LIVING/DINING
120
KITCHEN
121
LAUNDRY
124
COAT
126
BATH
127
BATH
107
?
?
LAUNDRY
104
CLOSET
109
CLOSET
129
KITCHEN
101
HALL
105
HALL
125
P1b
P3b
P12
P3b
P4 P4P7b P7b
1"
DC
W
1" DCW
1/2" DCW1/2" DCW
1"
DC
W
1/2
" D
CW
1" DCW1/2" DCW
1
2 5
7
4
6
8
1
25
7
4
6
8
EWH-1EWH-1
P9 P9
1515
1 1/2" DCW 1 1/2" DCW
1 1/2" DCW
16
16
1
2 5
7
3
4
6
8
1
25
7
3
4
6
8
1515
16
16
EXP-1EXP-1
P9 P9
P1b
LIVING/DINING
100
BEDROOM
108
BEDROOM
128
LIVING/DINING
120
KITCHEN
121
LAUNDRY
124
COAT
126
BATH
127
BATH
107
?
?
LAUNDRY
104
CLOSET
109
CLOSET
129
KITCHEN
101
HALL
105HALL
125P3b
P1b
P3b
P12
P4 P4P7b P7b
EWH-1EWH-1
1/2" DHW1/2" DHW
1/2" DHW
1" DHW
1/2
" D
HW
1/2
" D
HW
13
9
12
14
11
13
9
12
11
13
10
12
14
11
13
10
14
EXP-1 EXP-1
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/6
/20
21 8
:21
:36
AM
D:\R
evit 2
020
\Pro
jects
\81
83_
ME
P_
Lu
kach
ukai S
ch
oo
l -
Te
ach
era
ges_
AG
Sob
ers
.rvt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
PP101
PRESSUREPIPING PLAN -1BD/1BA DUPLEX
AS
20-7002.005
JRS/AGS
1/4" = 1'-0"A5 PRESSURE PIPING PLAN - DCW - 1BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
1. 1-1/2" DCW IN SEE CIVIL SITE PLAN FOR CONTINUATION.2. 1" DCW RISE UP IN WALL TO MULTI-MANIFOLD FITTING.3. 1" DCW DOWN AND CONNECT TO DWH-1, PROVIDE SHUT OFF BALL VALVE.4. 1/2" DCW TO P1a .5. PROVIDE (2) 1/2" DCW LINES DOWN FROM MULTI-MANIFOLD FITTING.6. 1/2" DCW UP IN WALL TO P7b.7. 1/2" DCW UP TO P3b.8. 3/4" DCW UP TO P12, WITH 1/2" DCW TO P4.9. 1" DHW DOWN IN WALL TO 1" HEADER.10. 1" DHW DOWN AND CONNECT TO DWH-1, PROVIDE SHUT OFF BALL VALVE.11. PROVIDE (3) 1/2" DHW LINES DOWN FROM MULTI-MANIFOLD FITTING.12. 1/2" DHW UP IN WALL TO P7b.13. 1/2" DHW UP TO P3b.14. 3/4" DHW UP TO P12, WITH 1/2" DHW TO P4.15. PROVIDE 1-1/2" WATER STUB OUT FOR FIRE PROTECTION FIRE RISER, SEE FIRE
PROTECTION PLANS FOR CONTINUATION.16. DOMESTIC WATER SHUT OFF VALVE IN CONCRETE PIT WITH CAST IRON LID.
A. ALL OVERHEAD EQUIPMENT AND PIPING IS TO BE SUSPENDED FROM STRUCTURAL MEMBERS.
0' 2' 4' 8'
0' 2' 4' 8'1/4" = 1'-0"C5 PRESSURE PIPING PLAN - DHW - 1BD/1BA DUPLEX
13
13
13 01-06-21 ADD-001T
LIVING/DINING
200
BEDROOM
206
MECH.
204
KITCHEN
201
BEDROOM
210
BATH
209
BATH
229
BEDROOM
230
LIVING/DINING
220
BEDROOM
226
MUD/LAUNDRY
223
MECH.
224
CLOSET
207
KITCHEN
221
P7bP7b
P3bP3b
P1bP1b
P12
1/2
" D
CW
1/2
" D
CW
1"
DC
W
1"
DC
W
1"
DC
W
1"
DC
W
1" DCW 1" DCW
1 1
/2"
DC
W
1 1
/2"
DC
W1"
DC
W
1"
DC
W
P9P9
1
15
2
8
3
5
66
1
3
8
5
P12
P4
44
EWH-2
EXP-2
EWH-2EXP-2
HP-4
15
1/2" DCW DOWN TO BELOW FLOOR EXTEND OVER TO P7a.
1/2" DCW DOWN TO BELOW FLOOR EXTEND OVER TO P7a.
P9P9
LIVING/DINING
200
BEDROOM
206
?
?
KITCHEN
201
BEDROOM
210
BATH
209
BATH
229
BEDROOM
230
LIVING/DINING
220
BEDROOM
226
MUD/LAUNDRY
223
MECH.
224
CLOSET
207
KITCHEN
221
P12
P4
P3b P3b
P1bP1b
P7bP7b
P4
P12
3/4" DHW
1/2
" D
HW
3/4
" D
HW
1/2
" D
HW
3/4
" D
HW
3/4" DHW
3/4
" D
HW
3/4
" D
HW
10
11 14
13
12
10
1114
13
12
EXP-2
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/6
/20
21 8
:20
:42
AM
D:\R
evit 2
020
\Pro
jects
\81
83_
ME
P_
Lu
kach
ukai S
ch
oo
l -
Te
ach
era
ges_
AG
Sob
ers
.rvt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
PP102
PRESSUREPIPING PLAN -2BD/1BA DUPLEX
AS
20-7002.005
JRS/AGS
1/4" = 1'-0"A5 PRESSURE PIPING PLAN - DCW - 2BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
A. ALL OVERHEAD EQUIPMENT AND PIPING IS TO BE SUSPENDED FROM STRUCTURAL MEMBERS.
0' 2' 4' 8'
0' 2' 4' 8'
1/4" = 1'-0"C5 PRESSURE PIPING PLAN - HW - 2BD/1BA DUPLEX
1. 1-1/2" DCW IN SEE CIVIL SITE PLAN FOR CONTINUATION.2. 1" DCW RISE UP IN WALL TO MULTI-MANIFOLD FITTING.3. 1" DCW DOWN AND CONNECT TO DWH-1, PROVIDE SHUT OFF BALL VALVE.4. 1/2" DCW TO P1a .5. PROVIDE (2) 1/2" DCW LINES DOWN FROM MULTI-MANIFOLD FITTING.6. 1/2" DCW UP IN WALL TO P7b.7. 1/2" DCW UP TO P3b.8. 3/4" DCW UP TO P12, WITH 1/2" DCW TO P4.9. 1" DHW DOWN IN WALL TO 1" HEADER.10. 1" DHW DOWN AND CONNECT TO DWH-1, PROVIDE SHUT OFF BALL VALVE.11. PROVIDE (3) 1/2" DHW LINES DOWN FROM MULTI-MANIFOLD FITTING.12. 1/2" DHW UP IN WALL TO P7b.13. 1/2" DHW UP TO P3b.14. 3/4" DHW UP TO P12, WITH 1/2" DHW TO P4.15. PROVIDE 1-1/2" WATER STUB OUT FOR FIRE PROTECTION FIRE RISER, SEE FIRE
PROTECTION PLANS FOR CONTINUATION.16. DOMESTIC WATER SHUT OFF VALVE IN CONCRETE PIT WITH CAST IRON LID.
DROP 1/2" DHW DOWN TO BELOW FLOOR AND EXTEND OVER TO P7b.
DROP 1/2" DHW DOWN TO BELOW FLOOR AND EXTEND OVER TO P7b.
13
13
13 01-06-21 ADD-001T
BEDROOM
302
LIVING/DINING
300
BEDROOM
313
BATH
312
BEDROOM
310
MECH.
307COAT
308
KITCHEN
304
MUD/LAUNDRY
306
P9
1
2
8
3
4 5
67
6
7 4
5
17
P4
P12
EWH-3
EXP-3
P7b
P1bP3b
P3bP3b
P7b
P1b
16
1" DCW
3/4" DCW1/2" DCW
1/2" DCW
1/2
" D
CW
1 1
/2"
DC
W
3/4
" D
CW
15
1"
DC
W
1" DCW
3/4" DCW
1/2" DCW3/4" DCW
1" DCW
3/4" DCW DOWN BELOW FLOOR AND OVER TO P7b.
P9
BEDROOM
302
LIVING/DINING
300
BEDROOM
313
BATH
312
BEDROOM
310
?
?
?
?
KITCHEN
304
MUD/LAUNDRY
306P4
P12
P1b
P1b
P3b
P3b P3b
P7b
P7b
9
14
12 13
12
18
13
11
3/4" DHW
3/4" DHW
1/2" DHW
3/4" DHW
3/4
" D
HW
3/4
" D
HW
1/2
" D
HW
1/2" DHW DOWN TO BELOW FLOOROVER TO P7b.
3/4" DHW RISE UP IN WALL.
10
EWH-3
EXP-3
D
GE
R
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
37368RANDALL
SWEARENGEN
EXPIRES 03/31/2023
)L
ACI
NA
HC
E(M
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/6
/20
21 7
:52
:08
AM
D:\R
evit 2
02
0\P
roje
cts
\818
3_M
EP
_Lu
kachu
kai S
ch
oo
l -
Te
ache
rag
es_
RK
Sch
am
p.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
PP103
PRESSUREPIPING PLAN -3BD/2BASINGLE-FAMILY
AS
20-7002.005
JRS/AGS
1/4" = 1'-0"A5 PRESSURE PIPING PLAN - DCW - 3BD/2BA SINGLE-FAMILY
GENERAL SHEET NOTES
SHEET KEYNOTES
1. XXXX.
A. ALL OVERHEAD EQUIPMENT AND PIPING IS TO BE SUSPENDED FROM STRUCTURAL MEMBERS.
0' 2' 4' 8'
0' 2' 4' 8'1/4" = 1'-0"C5 PRESSURE PIPING PLAN - DHW - 3BD/2BA SINGLE-FAMILY
1. 1-1/2" DCW IN SEE CIVIL SITE PLAN FOR CONTINUATION.2. 1" DCW RISE UP IN WALL TO MULTI-MANIFOLD FITTING.3. 1" DCW DOWN AND CONNECT TO DWH-1, PROVIDE SHUT OFF BALL VALVE.4. 1/2" DCW TO P1a .5. PROVIDE (2) 1/2" DCW LINES DOWN FROM MULTI-MANIFOLD FITTING.6. 1/2" DCW UP IN WALL TO P7b.7. 1/2" DCW UP TO P3b.8. 3/4" DCW UP TO P12, WITH 1/2" DCW TO P4.9. 1" DHW DOWN IN WALL TO 1" HEADER.10. 1" DHW DOWN AND CONNECT TO EWH-1, PROVIDE SHUT OFF BALL VALVE.11. PROVIDE (3) 1/2" DHW LINES DOWN FROM MULTI-MANIFOLD FITTING.12. 1/2" DHW UP IN WALL TO P7b.13. 1/2" DHW UP TO P3b.14. 3/4" DHW UP TO P12, WITH 1/2" DHW TO P4.15. PROVIDE 1-1/2" WATER STUB OUT FOR FIRE PROTECTION FIRE RISER, SEE FIRE
PROTECTION PLANS FOR CONTINUATION.16. DOMESTIC WATER SHUT OFF VALVE IN CONCRETE PIT WITH CAST IRON LID.17. 1-1/2" DOMESTIC COLD WATER TO RISE UP PROVIDE 3/4" NON FREEZE HOSE
BIBB (P9) DROP 1-1/2" DOMESTIC COLD WATER DOWN TO BELOW FLOOR AND OVER TO SERVE THE HOUSE.
18. 3/4" DHW UP IN WALL AND OVER.
13
13
13 01-06-21 ADD-001T
J
FS
J
LIVING/DINING
100 BEDROOM
108
BEDROOM
128
LIVING/DINING
120
KITCHEN
121LAUNDRY
124
COAT
126BATH
127
BATH
107
LAUNDRY
104
CLOSET
109CLOSET
129
KITCHEN
101
HALL
105 HALL
125
1A
WG
WG
EP02
EP04
EP05
EP01
EP06EP06
EP01
TYPICAL ELECTRICAL DEVICE LAYOUT AND CIRCUITING FOR ALL 1BD/1BA UNITS
EP07
EP01
1A - 18
HP-1
EP03
CU-1
1A - 5,7
1A - 16
1A - 8
1A - 22
1A - 9,111A - 1,3
1A - 13,15
G
TYP.
EP13
1A - 17,19
EP10 EP11
1A - 10
1A - 10
1A - 10
1A - 12
EP01
EP01
1A - 20
G
G
G
G
G
G
G
G1A - 12
1A - 12
EP01
1A - 14
CEF-10
1A - 2
1A - 2
1A - 2
1A - 2
1A - 2
1A - 6 1A - 6
1A - 6
1A
-6
STORAGE
110
1A - 4
1A - 4
1A - 4
1A - 4
G
CEF-8
1A - 24
1A - 24
EP12
EP12
EP12
EP08
EP09
EWH-1
1A - 10
WG1A - 6
1A - 24
CEF-15
FACP
1A - 26
EP14
EP15
EP16
EP16
EP16
EP17
EP17 EP17
EP18
EP19
EP20
13
COAT
106
LIVING/DINING
100
BEDROOM
108
BEDROOM
128
LIVING/DINING
120
KITCHEN
121
LAUNDRY
124
COAT
126
BATH
127
BATH
107
LAUNDRY
104
LAUNDRY
104
CLOSET
109
CLOSET
129
KITCHEN
101
HALL
105
HALL
125
1A
CS5
CS5
CS5
CS5
CS5
CS5
CS5
A1S
SF
D1S
B2
F
F
CS5
B2
1A - 24
TYPICAL LIGHTING LAYOUT AND CIRCUITING FOR ALL 1BD/1BA UNITS
STORAGE
110
STORAGE
130
13
3
CS5
3
13
COAT
106
13
D
GE
R
)L
ACI
RT
CE
L(
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I Z ON A U . S . A .
.
E
38934JOHN M.
MONTANO
EXPIRES 03/31/2021
~
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bri
dg
ers
& P
axto
n P
roje
ct
No
: 8
18
3
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 3
:52
:06
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_
ME
P_
Lu
ka
chu
kai S
cho
ol -
Tea
che
rag
es_
mjlo
vejo
y@
bpce.c
om
.rvt
Te
ach
era
ge
s
Lu
ka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
ch
uka
i, A
Z 8
65
07
E-101
ELECTRICALPLANS - 1BD/1BADUPLEX
JM
20-7002.005
MJL
1/4" = 1'-0"A5 POWER PLAN - 1BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
A. FOR ELECTRICAL LUMINAIRE SCHEDULE, SEE SHEET E-701. B. COVER PLATES OF ALL DEVICES WILL BE LABELED WITH CIRCUIT IT IS
CONNECTED TO, SUCH DEVICES ARE, BUT NOT LIMITED TO, SWITCHES AND RECEPTACLES. REFER TO SPECIFICATION SECTION 260553 FOR ADDITIONAL INFORMATION.
C. PROVIDE ARC FAULT CIRCUIT PROTECTION AS REQUIRED BY N.E.C.D. THE ELECTRICAL SERVICE FEEDER FROM THE UTILITY TRANSFORMER
THROUGH THE METER ENCLOSURE TO THE PANELBOARD SHALL BE IN CONDUIT. REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
E. GFCI RECEPTACLES WILL BE INSTALLED AT ALL LOCATIONS AS REQUIRED BY THE LATEST VERSION OF NEC, STATE AND LOCAL CODES WHETHER INDICATED ON PLANS OR NOT. SOME LOCATIONS WILL BE WITHIN 6'-0" OF SINKS, EXTERIOR DOORS AND WET LOCATIONS. ALL EXTERIOR RECEPTACLE LOCATIONS WILL BE GFCI RATED AND WEATHERPROOF.
F. COORDINATE ALL 120 VOLT POWER REQUIREMENTS AND LOCATIONS WITH THE CONTROLS / ACCESS / SECURITY CONTRACTORS IN THE FIELD. REFER TO SPECIFICATION 230549 FOR ADDITIONAL INFORMATION.
G. CONTROLS FOR ALL MECHANICAL EQUIPMENT WILL BE AS INDICATED ON SHEET SERIES "MI". RACEWAY PATHS FOR CONTROLS AND WIRING WILL BE INSTALLED AS INDICATED ON CONTROL DIAGRAMS. ALSO REFER TO SPECIFICATION SECTION 230549 FOR ADDITIONAL INFORMATION. CONTRACTOR WILL PROVIDE A 3/4" CONDUIT FOR CONTROL WIRING AS REQUIRED BY SHEET SERIES "MI". CONTROL WILL EITHER BE BY FACILITY MANAGEMENT SYSTEM (FMS) OR LOCAL SWITCHES. PROVIDE PILOT LIGHT SWITCHES WHERE LOCAL SWITCHES ARE REQUIRED PER CONTROL DIAGRAMS.
H. SUBMIT THREE (3) COPIES OF THE FIRE DETECTION ALARM SYSTEM, SHOP DRAWINGS, MANUFACTURER'S EQUIPMENT CATALOG DATA SHEETS, BATTERY CALCULATIONS AND VOLTAGE DROP CALCULATIONS TO THE DSRM FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. BIA SAFETY & HEALTH HANDBOOK TOPIC 26.6A.4.
0' 2' 4' 8'
0' 2' 4' 8'
EP01 MOUNT DEVICE(S) 6" ABOVE COUNTER TOP BACK SPLASH, TABLE TOP OR SINK. RECEPTACLEWILL BE GFCI RATED IF DESIGNATED WITH A "G".
EP02 MOUNT DEVICE 42” AFF BEHIND REFRIGERATOR. CONTRACTOR WILL MATCH NEMACONFIGURATION OF RECEPTACLE WITH UNIT PLUG. COORDINATE PRIOR TO ORDERINGRECEPTACLE DEVICE.
EP03 DISHWASHER. INSTALL OUTLET WITHIN BASE CABINETRY AT ACCESSIBLE LOCATION.COORDINATE WITH EQUIPMENT INSTALLER.
EP04 ELECTRIC RANGE/STOVE. MOUNT DEVICE BEHIND UNIT. CONTRACTOR WILL MATCH NEMACONFIGURATION OF RECEPTACLE WITH UNIT PLUG. COORDINATE PRIOR TO ORDERINGRECEPTACLE DEVICE. EXTEND 3#6 AND 1#10 GROUND IN 1" CONDUIT.
EP05 DEVICE TO SERVE RESIDENTIAL-TYPE EXHAUST HOOD (ABOVE COOKING RANGE). COORDINATEROUGH-IN LOCATION AND REQUIREMENTS WITH EQUIPMENT INSTALLER AND CASEWORKINSTALLER.
EP06 RESIDENTIAL-TYPE SINK DISPOSAL UNIT. OUTLET TO BE SWITCHED BY TOGGLE SWITCH ABOVECOUNTER. COORDINATE WITH SHEET SERIES "A" FOR EXACT LOCATION.
EP07 DEVICE FOR DRYER. COORDINATE NEMA CONFIGURATION IN FIELD WITH EQUIPMENT. EXTEND3#10 AND 1#10 GROUND IN 3/4" CONDUIT. MOUNT DEVICE AT 42" AFF.
EP08 DEVICE FOR WASHER. MOUNT DEVICE AT 42" AFF.
EP09 MOUNT GFCI RATED DEVICE FOR MICROWAVE. COORDINATE MOUNTING HEIGHT WITHARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN. PROVIDE DEDICATED CIRCUIT. LABELCOVER PLATE "MICROWAVE".
EP10 LOCATION OF METER AND SERVICE ENTRANCE EQUIPMENT. REFER TO ELECTRICAL SITE PLANON SHEET ES101 AND ELECTRICAL ONE-LINE DIAGRAM ON SHEET E-601 FOR SECONDARYFEEDER LOCATION. USE ALTERNATE LOCATION WHERE CONDITIONS DICTATE.
EP11 ALTERNATE LOCATION OF METER AND SERVICE ENTRANCE EQUIPMENT. REFER TO ELECTRICALSITE PLAN ON SHEET ES101 FOR SECONDARY FEEDER LOCATIONS.
EP12 FOR EACH UNIT, REFER TO SHEET SERIES "M-700" AND "P-700" FOR MECHANICAL EQUIPMENTCHARACTERISTICS. REFER TO SHEET E-701 FOR ELECTRICAL CONNECTION AND OTHERINFORMATION.
EP13 PROVIDE SMOKE DETECTORS PER NFPA REQUIREMENTS.
EP14 FIRE ALARM CONTROL PANEL (FACP). REFER TO FIRE ALARM RISER DIAGRAM ON SHEET E-601FOR ADDITIONAL INFORMATION.
EP15 COORDINATE FLOW SWITCH LOCATION WITH FIRE PROTECTION DRAWINGS. REFER TO FIREALARM RISER DIAGRAM ON SHEET E-601 FOR ADDITIONAL INFORMATION.
EP16 FIRE ALARM DEVICE FOR ADA UNITS ONLY.
EP17 INTEGRAL DISCONNECTING MEANS PROVIDED WITH EXHAUST FAN. CONTRACTOR TOTERMINATE WIRES AT INTERNAL PLUG ASSEMBLY.
EP18 SWITCH CONTROL PROVIDED BY DIVISION 23. ELECTRICAL CONTRACTOR TO INSTALL ALLINTERCONNECTIONS.
EP19 PROVIDE CARBON MONOXIDE DETECTOR. REFER TO FIRE ALARM RISER DIAGRAM ON SHEETE-601 FOR ADDITIONAL INFORMATION.
EP20 PROVIDE JUNCTION BOX WITH BLANK COVERPLATE IN ATTIC SPACE AND 1" CONDUIT WITH PULLROPE DOWN TO ELECTRICAL PANEL FOR FUTURE ACTIVE RADON VENTING. COORDINATELOCATION WITH ARCHITECT PRIOR TO ROUGH-IN.
ALL 15A AND 20A, 120V AND 250V, NONLOCKINGTYPE RECEPTACLES WILL BE TAMPER-RESISTANT
RECEPTACLES PER NEC 406.12. REFER TO NEC 406.12 FOR EXCEPTIONS.
1/4" = 1'-0"C5 LIGHTING PLAN - 1BD/1BA DUPLEX
13 01-06-21 ADD-001T
1/5/21
J
FS
J
LIVING/DINING
200
BEDROOM
206
KITCHEN
201
BEDROOM
210
BATH
209
BATH
229
BEDROOM
230
LIVING/DINING
220
BEDROOM
226
MUD/LAUNDRY
223
CLOSET
207
KITCHEN
221
TYPICAL ELECTRICAL DEVICE LAYOUT AND CIRCUITING FOR ALL 2BD/1BA UNITS
EP01
G
WG
2A
CLOSET
227
HP-3
G
2A - 8
CU-3
G
2A - 1,3
2A - 13,15
TYP.
EP13
WG
EP10 EP11
CEF-4
CEF-6
STORAGE
212
STORAGE
232
HALL
208HALL
228
EP02
EP04
EP05
EP06EP06
EP01
2A - 20
EP03
2A - 5,7
2A - 14
2A - 14
2A - 14
EP01
EP01
2A - 22
G
G
G
G
G
G
G
G2A - 12
2A - 12
EP01
EP09
EP07
2A - 24
EP08
2A - 2
2A - 2
2A - 2
2A - 2
2A - 10
2A - 4
2A - 4
2A - 4
2A - 4
2A - 6
2A - 62A - 6
2A - 6
2A - 10
2A - 10
2A - 102A - 10
EP01
2A - 9,11
2A - 12
2A - 16
2A - 18
2A - 26
2A - 26
EP12
EP12
EP12
EWH-2
2A - 14
2A - 2
2A - 26
CEF-13
FACP
2A - 28
EP14
EP16
EP16
EP16
EP16
EP15
EP17 EP17
EP17
EP18
EP19
EP20
13
MUD/LAUNDRY
203
COAT
205
CLOSET
211
CLOSET
231
COAT
225
2A - 17,19
WG2A - 10
13
TYPICAL LIGHTING LAYOUT AND CIRCUITING FOR ALL 2BD/1BA UNITS
BEDROOM
226CLOSET
207
BEDROOM
206
LIVING/DINING
200
BATH
209
BEDROOM
210
BEDROOM
230
BATH
229
LIVING/DINING
220
MUD/LAUNDRY
223
KITCHEN
221
CS5
CS5
CS5
CS5
CS5
CS5
CS5
A1S
SF
D1S
B2
F
CS5
CS5
CS5
2A
KITCHEN
201
3
CS5
2A - 26
P P
3
F
B2
HALL
208
STORAGE
212
STORAGE
232
MUD/LAUNDRY
203
COAT
205
CLOSET
211
CLOSET
231
HALL
228
COAT
225
13
13
D
GE
R
)L
ACI
RT
CE
L(
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I Z ON A U . S . A .
.
E
38934JOHN M.
MONTANO
EXPIRES 03/31/2021
~
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bri
dg
ers
& P
axto
n P
roje
ct
No
: 8
18
3
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 3
:52
:10
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_
ME
P_
Lu
ka
chu
kai S
cho
ol -
Tea
che
rag
es_
mjlo
vejo
y@
bpce.c
om
.rvt
Te
ach
era
ge
s
Lu
ka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
ch
uka
i, A
Z 8
65
07
E-102
ELECTRICALPLANS - 2BD/1BADUPLEX
JM
20-7002.005
MJL
1/4" = 1'-0"A5 POWER PLAN - 2BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
0' 2' 4' 8'
0' 2' 4' 8'
A. FOR ELECTRICAL LUMINAIRE SCHEDULE, SEE SHEET E-701. B. COVER PLATES OF ALL DEVICES WILL BE LABELED WITH CIRCUIT IT IS
CONNECTED TO, SUCH DEVICES ARE, BUT NOT LIMITED TO, SWITCHES AND RECEPTACLES. REFER TO SPECIFICATION SECTION 260553 FOR ADDITIONAL INFORMATION.
C. PROVIDE ARC FAULT CIRCUIT PROTECTION AS REQUIRED BY N.E.C.D. THE ELECTRICAL SERVICE FEEDER FROM THE UTILITY TRANSFORMER
THROUGH THE METER ENCLOSURE TO THE PANELBOARD SHALL BE IN CONDUIT. REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
E. GFCI RECEPTACLES WILL BE INSTALLED AT ALL LOCATIONS AS REQUIRED BY THE LATEST VERSION OF NEC, STATE AND LOCAL CODES WHETHER INDICATED ON PLANS OR NOT. SOME LOCATIONS WILL BE WITHIN 6'-0" OF SINKS, EXTERIOR DOORS AND WET LOCATIONS. ALL EXTERIOR RECEPTACLE LOCATIONS WILL BE GFCI RATED AND WEATHERPROOF.
F. COORDINATE ALL 120 VOLT POWER REQUIREMENTS AND LOCATIONS WITH THE CONTROLS / ACCESS / SECURITY CONTRACTORS IN THE FIELD. REFER TO SPECIFICATION 230549 FOR ADDITIONAL INFORMATION.
G. CONTROLS FOR ALL MECHANICAL EQUIPMENT WILL BE AS INDICATED ON SHEET SERIES "MI". RACEWAY PATHS FOR CONTROLS AND WIRING WILL BE INSTALLED AS INDICATED ON CONTROL DIAGRAMS. ALSO REFER TO SPECIFICATION SECTION 230549 FOR ADDITIONAL INFORMATION. CONTRACTOR WILL PROVIDE A 3/4" CONDUIT FOR CONTROL WIRING AS REQUIRED BY SHEET SERIES "MI". CONTROL WILL EITHER BE BY FACILITY MANAGEMENT SYSTEM (FMS) OR LOCAL SWITCHES. PROVIDE PILOT LIGHT SWITCHES WHERE LOCAL SWITCHES ARE REQUIRED PER CONTROL DIAGRAMS.
H. SUBMIT THREE (3) COPIES OF THE FIRE DETECTION ALARM SYSTEM, SHOP DRAWINGS, MANUFACTURER'S EQUIPMENT CATALOG DATA SHEETS, BATTERY CALCULATIONS AND VOLTAGE DROP CALCULATIONS TO THE DSRM FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. BIA SAFETY & HEALTH HANDBOOK TOPIC 26.6A.4.
EP01 MOUNT DEVICE(S) 6" ABOVE COUNTER TOP BACK SPLASH, TABLE TOP OR SINK. RECEPTACLEWILL BE GFCI RATED IF DESIGNATED WITH A "G".
EP02 MOUNT DEVICE 42” AFF BEHIND REFRIGERATOR. CONTRACTOR WILL MATCH NEMACONFIGURATION OF RECEPTACLE WITH UNIT PLUG. COORDINATE PRIOR TO ORDERINGRECEPTACLE DEVICE.
EP03 DISHWASHER. INSTALL OUTLET WITHIN BASE CABINETRY AT ACCESSIBLE LOCATION.COORDINATE WITH EQUIPMENT INSTALLER.
EP04 ELECTRIC RANGE/STOVE. MOUNT DEVICE BEHIND UNIT. CONTRACTOR WILL MATCH NEMACONFIGURATION OF RECEPTACLE WITH UNIT PLUG. COORDINATE PRIOR TO ORDERINGRECEPTACLE DEVICE. EXTEND 3#6 AND 1#10 GROUND IN 1" CONDUIT.
EP05 DEVICE TO SERVE RESIDENTIAL-TYPE EXHAUST HOOD (ABOVE COOKING RANGE). COORDINATEROUGH-IN LOCATION AND REQUIREMENTS WITH EQUIPMENT INSTALLER AND CASEWORKINSTALLER.
EP06 RESIDENTIAL-TYPE SINK DISPOSAL UNIT. OUTLET TO BE SWITCHED BY TOGGLE SWITCH ABOVECOUNTER. COORDINATE WITH SHEET SERIES "A" FOR EXACT LOCATION.
EP07 DEVICE FOR DRYER. COORDINATE NEMA CONFIGURATION IN FIELD WITH EQUIPMENT. EXTEND3#10 AND 1#10 GROUND IN 3/4" CONDUIT. MOUNT DEVICE AT 42" AFF.
EP08 DEVICE FOR WASHER. MOUNT DEVICE AT 42" AFF.
EP09 MOUNT GFCI RATED DEVICE FOR MICROWAVE. COORDINATE MOUNTING HEIGHT WITHARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN. PROVIDE DEDICATED CIRCUIT. LABELCOVER PLATE "MICROWAVE".
EP10 LOCATION OF METER AND SERVICE ENTRANCE EQUIPMENT. REFER TO ELECTRICAL SITE PLANON SHEET ES101 AND ELECTRICAL ONE-LINE DIAGRAM ON SHEET E-601 FOR SECONDARYFEEDER LOCATION. USE ALTERNATE LOCATION WHERE CONDITIONS DICTATE.
EP11 ALTERNATE LOCATION OF METER AND SERVICE ENTRANCE EQUIPMENT. REFER TO ELECTRICALSITE PLAN ON SHEET ES101 FOR SECONDARY FEEDER LOCATIONS.
EP12 FOR EACH UNIT, REFER TO SHEET SERIES "M-700" AND "P-700" FOR MECHANICAL EQUIPMENTCHARACTERISTICS. REFER TO SHEET E-701 FOR ELECTRICAL CONNECTION AND OTHERINFORMATION.
EP13 PROVIDE SMOKE DETECTORS PER NFPA REQUIREMENTS.
EP14 FIRE ALARM CONTROL PANEL (FACP). REFER TO FIRE ALARM RISER DIAGRAM ON SHEET E-601FOR ADDITIONAL INFORMATION.
EP15 COORDINATE FLOW SWITCH LOCATION WITH FIRE PROTECTION DRAWINGS. REFER TO FIREALARM RISER DIAGRAM ON SHEET E-601 FOR ADDITIONAL INFORMATION.
EP16 FIRE ALARM DEVICE FOR ADA UNITS ONLY.
EP17 INTEGRAL DISCONNECTING MEANS PROVIDED WITH EXHAUST FAN. CONTRACTOR TOTERMINATE WIRES AT INTERNAL PLUG ASSEMBLY.
EP18 SWITCH CONTROL PROVIDED BY DIVISION 23. ELECTRICAL CONTRACTOR TO INSTALL ALLINTERCONNECTIONS.
EP19 PROVIDE CARBON MONOXIDE DETECTOR. REFER TO FIRE ALARM RISER DIAGRAM ON SHEETE-601 FOR ADDITIONAL INFORMATION.
EP20 PROVIDE JUNCTION BOX WITH BLANK COVERPLATE IN ATTIC SPACE AND 1" CONDUIT WITH PULLROPE DOWN TO ELECTRICAL PANEL FOR FUTURE ACTIVE RADON VENTING. COORDINATELOCATION WITH ARCHITECT PRIOR TO ROUGH-IN.
ALL 15A AND 20A, 120V AND 250V, NONLOCKINGTYPE RECEPTACLES WILL BE TAMPER-RESISTANT
RECEPTACLES PER NEC 406.12. REFER TO NEC 406.12 FOR EXCEPTIONS.
1/4" = 1'-0"C5 LIGHTING PLAN - 2BD/1BA DUPLEX
13 01-06-21 ADD-001T
1/5/21
J
FS
J
BEDROOM
302
LIVING/DINING
300
BEDROOM
313
BATH
312
BEDROOM
310
KITCHEN
304
MUD/LAUNDRY
306
TYPICAL ELECTRICAL DEVICE LAYOUT AND CIRCUITING FOR ALL 3BD/2BA UNITS
3A
EP01EP01
EP01
G
G G
WG
WG
BATH
303
CU-5
3A - 123A - 10
3A - 14
HP-5
G
TYP.
EP13
EP10
STORAGE
315
CLOSET
309
HALL
311
CLOSET
314
CLOSET
301
CEF-1
CEF-3
CEF-2
3A - 8
3A - 8
3A - 8
3A - 8
3A - 6
3A - 6
3A - 6
3A - 6
3A - 6
3A - 8
3A - 6
3A - 4
3A - 4
3A - 4
3A - 43A - 4
3A - 4
3A - 2
3A - 2
3A - 2
3A - 2
3A - 2
3A - 2
EP02
EP04
EP05
3A - 24
3A - 5,7
3A - 18
3A - 18
3A - 18
EP01
EP01
3A - 26
G
G
G
G
EP09
EP01
EP06EP06
EP01
EP03G
G
G
G3A - 16
3A - 16
EP01
3A - 20
3A - 22
3A - 1,3
3A - 13,15
EP07
3A - 28
EP08
3A - 9,11
3A - 30
3A - 30
EP12
EP12
3A - 17,19
EP12
3A - 16
EWH-33A - 18
WG3A - 8
3A - 30
CEF-12
3A - 30
FACP EP14
EP16
EP16
EP16
EP16
EP16
EP15
EP17EP17
EP17
EP17
EP18
EP18
3A - 29
EP19
EP20
13
13
COAT
308
TYPICAL LIGHTING LAYOUT AND CIRCUITING FOR ALL 3BD/2BA UNITS
BEDROOM
302
KITCHEN
304
MUD/LAUNDRY
306
BEDROOM
310
LIVING/DINING
300
BATH
312
BEDROOM
313
3A
CS5
CS5
CS5
CS5
CS5
D1S
B2
F
CS5
CS5
3
3
CS5
SF
F
CS5
CS5
CS5
A1S
CS5
CS5
CS5
3A - 30
CS5
B2
P P
BATH
303
CLOSET
301
STORAGE
315
CLOSET
309
HALL
311
CLOSET
314
D1S D1S
13
13
COAT
308
13
13
D
GE
R
)L
ACI
RT
CE
L(
REENIGNELANOISSEF
ORPD
ER
ET
S I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I Z ON A U . S . A .
.
E
38934JOHN M.
MONTANO
EXPIRES 03/31/2021
~
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bri
dg
ers
& P
axto
n P
roje
ct
No
: 8
18
3
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 3
:52
:13
PM
D:\R
evit 2
02
0\P
roje
cts
\818
3_
ME
P_
Lu
ka
chu
kai S
cho
ol -
Tea
che
rag
es_
mjlo
vejo
y@
bpce.c
om
.rvt
Te
ach
era
ge
s
Lu
ka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
ch
uka
i, A
Z 8
65
07
E-103
ELECTRICALPLANS - 3BD/2BASINGLE-FAMILY
JM
20-7002.005
MJL
1/4" = 1'-0"A5 POWER PLAN - 3BD/2BA SINGLE-FAMILY
GENERAL SHEET NOTES
SHEET KEYNOTES
0' 2' 4' 8'
0' 2' 4' 8'
A. FOR ELECTRICAL LUMINAIRE SCHEDULE, SEE SHEET E-701. B. COVER PLATES OF ALL DEVICES WILL BE LABELED WITH CIRCUIT IT IS
CONNECTED TO, SUCH DEVICES ARE, BUT NOT LIMITED TO, SWITCHES AND RECEPTACLES. REFER TO SPECIFICATION SECTION 260553 FOR ADDITIONAL INFORMATION.
C. PROVIDE ARC FAULT CIRCUIT PROTECTION AS REQUIRED BY N.E.C.D. THE ELECTRICAL SERVICE FEEDER FROM THE UTILITY TRANSFORMER
THROUGH THE METER ENCLOSURE TO THE PANELBOARD SHALL BE IN CONDUIT. REFER TO ONE-LINE DIAGRAM FOR ADDITIONAL INFORMATION.
E. GFCI RECEPTACLES WILL BE INSTALLED AT ALL LOCATIONS AS REQUIRED BY THE LATEST VERSION OF NEC, STATE AND LOCAL CODES WHETHER INDICATED ON PLANS OR NOT. SOME LOCATIONS WILL BE WITHIN 6'-0" OF SINKS, EXTERIOR DOORS AND WET LOCATIONS. ALL EXTERIOR RECEPTACLE LOCATIONS WILL BE GFCI RATED AND WEATHERPROOF.
F. COORDINATE ALL 120 VOLT POWER REQUIREMENTS AND LOCATIONS WITH THE CONTROLS / ACCESS / SECURITY CONTRACTORS IN THE FIELD. REFER TO SPECIFICATION 230549 FOR ADDITIONAL INFORMATION.
G. CONTROLS FOR ALL MECHANICAL EQUIPMENT WILL BE AS INDICATED ON SHEET SERIES "MI". RACEWAY PATHS FOR CONTROLS AND WIRING WILL BE INSTALLED AS INDICATED ON CONTROL DIAGRAMS. ALSO REFER TO SPECIFICATION SECTION 230549 FOR ADDITIONAL INFORMATION. CONTRACTOR WILL PROVIDE A 3/4" CONDUIT FOR CONTROL WIRING AS REQUIRED BY SHEET SERIES "MI". CONTROL WILL EITHER BE BY FACILITY MANAGEMENT SYSTEM (FMS) OR LOCAL SWITCHES. PROVIDE PILOT LIGHT SWITCHES WHERE LOCAL SWITCHES ARE REQUIRED PER CONTROL DIAGRAMS.
H. SUBMIT THREE (3) COPIES OF THE FIRE DETECTION ALARM SYSTEM, SHOP DRAWINGS, MANUFACTURER'S EQUIPMENT CATALOG DATA SHEETS, BATTERY CALCULATIONS AND VOLTAGE DROP CALCULATIONS TO THE DSRM FOR REVIEW AND APPROVAL PRIOR TO INSTALLATION. BIA SAFETY & HEALTH HANDBOOK TOPIC 26.6A.4.
EP01 MOUNT DEVICE(S) 6" ABOVE COUNTER TOP BACK SPLASH, TABLE TOP OR SINK. RECEPTACLEWILL BE GFCI RATED IF DESIGNATED WITH A "G".
EP02 MOUNT DEVICE 42” AFF BEHIND REFRIGERATOR. CONTRACTOR WILL MATCH NEMACONFIGURATION OF RECEPTACLE WITH UNIT PLUG. COORDINATE PRIOR TO ORDERINGRECEPTACLE DEVICE.
EP03 DISHWASHER. INSTALL OUTLET WITHIN BASE CABINETRY AT ACCESSIBLE LOCATION.COORDINATE WITH EQUIPMENT INSTALLER.
EP04 ELECTRIC RANGE/STOVE. MOUNT DEVICE BEHIND UNIT. CONTRACTOR WILL MATCH NEMACONFIGURATION OF RECEPTACLE WITH UNIT PLUG. COORDINATE PRIOR TO ORDERINGRECEPTACLE DEVICE. EXTEND 3#6 AND 1#10 GROUND IN 1" CONDUIT.
EP05 DEVICE TO SERVE RESIDENTIAL-TYPE EXHAUST HOOD (ABOVE COOKING RANGE). COORDINATEROUGH-IN LOCATION AND REQUIREMENTS WITH EQUIPMENT INSTALLER AND CASEWORKINSTALLER.
EP06 RESIDENTIAL-TYPE SINK DISPOSAL UNIT. OUTLET TO BE SWITCHED BY TOGGLE SWITCH ABOVECOUNTER. COORDINATE WITH SHEET SERIES "A" FOR EXACT LOCATION.
EP07 DEVICE FOR DRYER. COORDINATE NEMA CONFIGURATION IN FIELD WITH EQUIPMENT. EXTEND3#10 AND 1#10 GROUND IN 3/4" CONDUIT. MOUNT DEVICE AT 42" AFF.
EP08 DEVICE FOR WASHER. MOUNT DEVICE AT 42" AFF.
EP09 MOUNT GFCI RATED DEVICE FOR MICROWAVE. COORDINATE MOUNTING HEIGHT WITHARCHITECTURAL ELEVATIONS PRIOR TO ROUGH-IN. PROVIDE DEDICATED CIRCUIT. LABELCOVER PLATE "MICROWAVE".
EP10 LOCATION OF METER AND SERVICE ENTRANCE EQUIPMENT. REFER TO ELECTRICAL SITE PLANON SHEET ES101 AND ELECTRICAL ONE-LINE DIAGRAM ON SHEET E-601 FOR SECONDARYFEEDER LOCATION. USE ALTERNATE LOCATION WHERE CONDITIONS DICTATE.
EP12 FOR EACH UNIT, REFER TO SHEET SERIES "M-700" AND "P-700" FOR MECHANICAL EQUIPMENTCHARACTERISTICS. REFER TO SHEET E-701 FOR ELECTRICAL CONNECTION AND OTHERINFORMATION.
EP13 PROVIDE SMOKE DETECTORS PER NFPA REQUIREMENTS.
EP14 FIRE ALARM CONTROL PANEL (FACP). REFER TO FIRE ALARM RISER DIAGRAM ON SHEET E-601FOR ADDITIONAL INFORMATION.
EP15 COORDINATE FLOW SWITCH LOCATION WITH FIRE PROTECTION DRAWINGS. REFER TO FIREALARM RISER DIAGRAM ON SHEET E-601 FOR ADDITIONAL INFORMATION.
EP16 FIRE ALARM DEVICE FOR ADA UNITS ONLY.
EP17 INTEGRAL DISCONNECTING MEANS PROVIDED WITH EXHAUST FAN. CONTRACTOR TOTERMINATE WIRES AT INTERNAL PLUG ASSEMBLY.
EP18 SWITCH CONTROL PROVIDED BY DIVISION 23. ELECTRICAL CONTRACTOR TO INSTALL ALLINTERCONNECTIONS.
EP19 PROVIDE CARBON MONOXIDE DETECTOR. REFER TO FIRE ALARM RISER DIAGRAM ON SHEETE-601 FOR ADDITIONAL INFORMATION.
EP20 PROVIDE JUNCTION BOX WITH BLANK COVERPLATE IN ATTIC SPACE AND 1" CONDUIT WITH PULLROPE DOWN TO ELECTRICAL PANEL FOR FUTURE ACTIVE RADON VENTING. COORDINATELOCATION WITH ARCHITECT PRIOR TO ROUGH-IN.
ALL 15A AND 20A, 120V AND 250V, NONLOCKINGTYPE RECEPTACLES WILL BE TAMPER-RESISTANT
RECEPTACLES PER NEC 406.12. REFER TO NEC 406.12 FOR EXCEPTIONS.
1/4" = 1'-0"C5 LIGHTING PLAN - 3BD/2BA SINGLE-FAMILY
13 01-06-21 ADD-001T
1/5/21
22
T01T01
T02T02
+4' - 0"+4' - 0"
D
GE
R
)L
ACI
RT
CE
L(
REENIGNELANOISSEF
ORP
DE
RE
TS I
CIFITREC .
ONETA
A
TES IGNED . . . . .
AR I ZONA U. S . A .
.
E
38934JOHN M.
MONTANO
EXPIRES 03/31/2021
~
1
A
2 3 4 5 6
B
C
D
E
1 2 3 4 5 6
PROJECT
REVISIONS
SHEET NO
DRAWING NAME
SEAL
DATE
REVIEWED BY
PROJECT NO
DRAWN BY
12-10-2020
Bridgers
& P
axto
n P
roje
ct N
o: 8183
100%CONSTRUCTION
DOCUMENTS
1/5
/20
21 2
:23
:43
PM
D:\R
evit 2
020
\Pro
jects
\81
83
_M
EP
_L
uka
chu
kai S
ch
oo
l -
Te
ach
era
ge
s_N
DN
an
os.r
vt
Teachera
ges
Luka
ch
uka
i C
om
mu
nity S
ch
oo
lsIn
ters
ectio
n I
R 1
2 a
nd
IR
13
Lu
ka
chu
ka
i, A
Z 8
65
07
T-101
TECHNOLOGYSYSTEMS PLAN -1BD/1BA DUPLEX
Approver
20-7002.005
Author
1/4" = 1'-0"A5 TECHNOLOGY SYSTEMS PLAN - 1BD/1BA DUPLEX
GENERAL SHEET NOTES
SHEET KEYNOTES
0' 2' 4' 8'
T01 STANDARD TELECOMMUNICATIONS WALL OUTLET. QUANTITY OF RJ45 OUTLETS ASSHOWN. INTERIOR PATHWAYS ARE DEPENDANT ON EACH BUILDING ENTRY POINT.REFER TO TS-101.
T02 STANDARD TELEVISION WALL OUTLET. QUANTITY OF (1) RG-6 COAXIAL OUTLET.INTERIOR PATHWAYS SHOULD LEAD TO SOUTHERN WALL FOR SATTELITE SERVICEPROVIDER AS PER PLACEMENT OF EACH BUILDING.
A. PROPERLY FIRE STOP AND SEAL ALL PENETRATIONS THROUGH WALLS, FLOORS, CEILINGS, AND ROOF AS PER OWNER, CODE, AND AHJ.
B. PRIOR TO INSTALLATION OF CABLE TRAY COORDINATE LOCATIONS WITH ALL OTHER TRADES.
C. NOT ALL PARTS AND PIECES ARE SHOWN FOR A COMPLETE SYSTEM. CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE END-TO-END WARRANTED SOLUTION FOR THE HORIZONTAL CABLING.
D. ALL CABLING TO BE PLENUM RATED THROUGHOUT THE BUILDING.E. ALL COMMUNICATIONS CABLING TO MEET OR EXCEED CATEGORY 6
STANDARDS.F. TELECOMMUNICATIONS OUTLETS TO BE MOUNTED AT +18" AFF UNLESS
OTHERWISE NOTED. FOR EXAMPLE, DEVICES SPECIFIED AT +18" AFF SHALL MATCH THE STANDARD MOUNTING HEIGHT FOR POWER RECEPTACLES AND TELECOMMUNICATIONS OUTLETS. DEVICES SPECIFIED AT +44" AFF SHALL MATCH THE STANDARD MOUNTING HEIGHT FOR LIGHT SWITCHES ETC.
G. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS SHALL BE STEEL, THINWALL ELECTRICAL METALLIC TUBING (TYPE EMT) UNLESS OTHERWISE NOTED. UNDER NO CIRCUMSTANCES SHALL FLEXIBLE CONDUIT BE USED FOR PATHWAYS INDICATED ON THIS SHEET. ALL CONDUITS ARE TO BE, AT A MINIMUM, 1” TRADE SIZE, UNLESS OTHERWISE NOTED. ALL CONDUITS FOR TELECOMMUNICATIONS OUTLETS ARE TO BE STUBBED TO NEAREST CABLE TRAY. CONTRACTOR IS TO ENSURE THAT NO CONDUIT EXCEEDS 40% FILL.
H. CABLE TRAY SYSTEMS SHOWN ON THIS SHEET SHALL BE USED FOR VOICE AND DATA CABLING ONLY. ALL OTHER SYSTEMS INCLUDING, BUT NOT LIMITED TO, FIRE ALARM, SECURITY, HVAC CONTROL, ETC. SHALL BE SUPPORTED BY OTHER MEANS. J-HOOKS ATTACHED TO THE CABLE TRAY SUPPORTS WILL BE PERMITTED. LIKEWISE, ANY CONDUITS PROVIDED FOR VOICE AND DATA CABLING IS NOT TO BE USED BY ANY OTHER SYSTEM, HENCE, SEPARATE CONDUITS MAY NEED TO BE PROVIDED FOR THE SUPPORT OF THESE SYSTEMS.
I. NUMBER ADJACENT TO TELECOMMUNICATIONS OUTLET SYMBOL REPRESENTS NUMBER OF CATEGORY 6 CABLES TO BE INSTALLED AND TERMINATED AT THAT LOCATION. A "B" ADJACENT TO AN OUTLET LOCATION REPRESENTS A ROUGH-IN ONLY LOCATION, PROVIDE BOX, CONDUIT, AND BLANK FACEPLATE.
J. COORDINATE WITH FLOOR AND FURNITURE CONTRACTORS FOR PATHWAYS FOR VOICE/DATA OUTLETS FOR MODULAR FURNITURE SYSTEMS.
13 01-06-21 ADD-001T
13
13
13
13
1/5/21