Main Office: 155 George Street, Prince George, BC V2L 1P8
Telephone: 250-960-4400 / Fax: 250-562-8676
Toll Free: 1-800-667-1959 / http://www.rdffg.bc.ca
Addendum No. 1
Invitation to Tender ES-19-11
Shoreline Stabilization & Drainage Works Harold Mann Regional Park
The addendum is being issued prior to the closing of the Invitation to Tender to provide further information, make changes to, or to clarify the Contract Documents and is to be read, interpreted and coordinated with all other parts of the Contract Documents. In case of a conflict with the balance of the documents, this Addendum shall govern. Tenderers shall attach a signed copy of this addendum to their tender. This addendum shall form part of the Contract Documents.
Replace Appendix A and Appendix B with corrected Appendix A: Site Layout and Appendix B: Design Drawings.
June 20, 2019
Addendum No. 1 Received.
Signature of Tenderer Name of Tenderer
Inquiries relating to this ITT may be directed to:
Technical Inquiries:
Bryan Boyes Utilities Leader
Regional District of Fraser-Fort George 155 George Street
Prince George BC V2L 1P8 Telephone: 250-960-4400 Fax: 250-562-
8676 Email: [email protected]
General Inquiries:
Petra Wildauer General Manager of Environmental Services
Regional District of Fraser-Fort George 155 George Street
Prince George, BC V2L 1P8 Phone: 250-960-4400 / Fax: 250-526-8676
Email: [email protected]
Shoreline Stabilization & Drainage Works Harold Mann Regional Park
Invitation to Tender ES-19-11 October 1, 2019 – October 31, 2019
Page 29 of 32
APPENDIX A - SITE LAYOUT
77C434
SPK6 FOCUS
SPK1 FOCUS
1200Ø
HAROLD MANN REG. PARK
NO CAMPING
ATTENTION ALL VISITORS
NO LIFEGUARD
EAGLET LAKE FISHERIES MGMT.
1212
SPK
1476
SPK
LOT 1
LOT 2
REM DL7946
DL7945
P
L
A
N
2
5
0
3
3
P
L
A
N
A
-
2
7
8
7
R
O
A
D
P
L
A
N
E
P
P
4
3
0
7
4
6
0
0
6
0
5
6
0
0
16-1
16-2
SURVEY CONTROL TABLE
POINT
NAME
77C434
1212
1456
1476
NORTHING
5994787.247
5994787.465
5994858.675
5994665.748
EASTING
543897.558
543891.678
544069.101
543724.991
ELEVATION
603.998
604.130
609.411
599.753
DESCRIPTION
FMON
SPK
SPK
SPK
DA
TE
: 2
01
6-1
0-1
9, 1
4:4
1 F
IL
E: H
:\P
RO
J\2
34
1\2
20
0-2
29
9\2
21
4 - R
DF
FG
H
aro
ld
M
an
n R
eg
io
na
l P
ark S
ho
re
lin
e\1
0.0
D
ra
win
gs\1
0.3
M
od
els\V
-M
OD
L.d
wg
Drawn DesignDescriptionRev Date App'd ORIGINAL DWG SIZE: ANSI D (22" x 34")
Rev.
Drawing No.
DE
ST
RO
Y A
LL
P
RIN
TS
B
EA
RIN
G P
RE
VIO
US
R
EV
IS
IO
N
Approved Sealed
Project Number
THIS DRAWING AND DESIGN IS THE PROPERTY OF McELHANNEY CONSULTING SERVICES LTD. (McELHANNEY)
AND SHALL NOT BE USED, REUSED OR REPRODUCED WITHOUT THE CONSENT OF McELHANNEY. McELHANNEY
WILL NOT BE HELD RESPONSIBLE FOR THE IMPROPER OR UNAUTHORIZED USE OF THIS DRAWING AND DESIGN.
THIS DRAWING AND DESIGN HAS BEEN PREPARED FOR THE CLIENT IDENTIFIED, TO MEET THE STANDARDS AND
REQUIREMENTS OF THE APPLICABLE PUBLIC AGENCIES AT THE TIME OF PREPARATION. McELHANNEY, ITS
EMPLOYEES, SUBCONSULTANTS AND AGENTS WILL NOT BE LIABLE FOR ANY LOSSES OR OTHER
CONSEQUENCES RESULTING FROM THE USE OR RELIANCE UPON, OR ANY CHANGES MADE TO, THIS DRAWING,
BY ANY THIRD PARTY, INCLUDING CONTRACTORS, SUPPLIERS, CONSULTANTS AND STAKEHOLDERS, OR THEIR
EMPLOYEES OR AGENTS, WITHOUT McELHANNEY'S PRIOR WRITTEN CONSENT.
INFORMATION ON EXISTING UNDERGROUND FACILITIES MAY NOT BE COMPLETE OR ACCURATE. McELHANNEY,
ITS EMPLOYEES AND DIRECTORS ARE NOT RESPONSIBLE NOR LIABLE FOR THE LOCATION OF ANY
UNDERGROUND CONDUITS, PIPES, CABLES OR OTHER FACILITIES WHETHER SHOWN OR OMITTED FROM THIS
PLAN. PRIOR TO CONSTRUCTION CONTRACTOR SHALL EXPOSE LOCATIONS OF ALL EXISTING FACILITIES BY
HAND DIGGING OR HYDROVAC AND ADVISE THE ENGINEER OF POTENTIAL CONFLICTS.
McE
lh
an
ne
y A
NS
I D
- 1
5-0
5-2
2
Suite 12556 North Nechako RoadPrince George BCCanada V2K 1A1Tel 250 561 2229
REGIONAL DISTRICT OF FRASER - FORT GEORGE
155 GEORGE STREET, PRINCE GEORGE, BC, V2L 1P8
HAROLD MANN REGIONAL PARK
SITE SURVEY
PLAN - EXISTING CONDITION
101
2341-02214-00 0
0 16-10-19 ISSUED TO CLIENT SAB - DK
0 1:500 25
EAGLET LAKE
U
P
P
E
R
F
R
A
S
E
R
R
O
A
D
GRAVEL PARKING
PIT TOILETS
GATE
SERVICE BOX
RECYCLE BIN
L
O
G
R
A
I
L
F
E
N
C
E
WOOD STEPS
STONE STEPS
MEMORIAL STONE
BUILDING
BUILDINGS
GARBAGE BIN
GARBAGE BIN
CULVERT INLET NOT LOCATED
T
O
G
I
S
C
O
M
E
FOUND SET
IRON POST
SURVEY CONTROL
MONUMENT
SURVEY
CONIFEROUS TREE
POST MOUNTED SIGN
SIGN ON TWO POSTS
TEST PIT
SITE FEATURES
EXISTING
LEGEND
BOTTOM OF BANK
UNPAVED ROAD
PAVED ROAD
TOP OF BANK
WOOD FENCE
NOTES
· SURVEYED BY McELHANNEY CONSULTING SERVICES Ltd. (J. GAYOWSKI & M. BOWE) September 14, 2016
· COORDINATES ARE GRID, BASED ON UTM ZONE 10, NAD83 (CSRS) 2002.0 PROCESSED USING NATURAL
RESOURCES CANADA'S PRECISE POINT POSITIONING SERVICE. COMBINED SCALE FACTOR AT POINT
1476 IS 0.99953147
· ELEVATIONS ARE RELATIVE TO CGVD28 (HT 2.0)
· THE PROPERTY BOUNDARIES SHOWN ARE COMPILED FROM LEGAL PLANS AND A SUFFICIENT NUMBER
OF FIELD TIES TO IRON POSTS. THEY SHOULD BE USED ACCORDINGLY.
· NO UNDERGROUND UTILITIES WERE LOCATED FOR THIS SURVEY.
· CONTOUR INTERVAL IS 1m
Shoreline Stabilization & Drainage Works Harold Mann Regional Park
Invitation to Tender ES-19-11 October 1, 2019 – October 31, 2019
Page 31 of 32
APPENDIX B - DESIGN DRAWINGS
DA
TE
: 2017-03-03
, 09:20
F
ILE
: H
:\P
RO
J\2341\2200-2299\2214 - R
DF
FG
H
arold M
ann R
egional P
ark S
horeline\10.0 D
raw
ings\10.3 M
odels\20170303 V
-M
OD
L1.dw
g
ORIGINAL DWG SIZE: ANSI D (22" x 34")
Rev.
Drawing No.
Approved Sealed
Project Number
McE
lhanney A
NS
I D
- 15-05-22
Suite 12556 North Nechako RoadPrince George BCCanada V2K 1A1Tel 250 561 2229
155 GEORGE STREET, PRINCE GEORGE, BC, V2L 1P8
HAROLD MANN REGIONAL PARK
MULTI-FLOW DRAIN CONCEPT
A
EAGLET LAKE
U
P
P
E
R
F
R
A
S
E
R
R
O
A
D
GRAVEL PARKING
PIT TOILETS
GATE
SERVICE BOX
RECYCLE BIN
L
O
G
R
A
I
L
F
E
N
C
E
WOOD STEPS
STONE STEPS
MEMORIAL STONE
BUILDING
BUILDINGS
GARBAGE BIN
GARBAGE BIN
CULVERT INLET NOT LOCATED
T
O
G
I
S
C
O
M
E
FOUND SET
IRON POST
SURVEY CONTROL
MONUMENT
SURVEY
CONIFEROUS TREE
POST MOUNTED SIGN
SIGN ON TWO POSTS
TEST PIT
SITE FEATURES
EXISTING
LEGEND
BOTTOM OF BANK
UNPAVED ROAD
PAVED ROAD
TOP OF BANK
WOOD FENCE
MULTI-FLOW UNDER
PATH OR LANDSCAPING
MULTI-FLOW UNDER
PICNIC TABLE PAD
PICNIC TABLE
EXISTING
WETLAND
TYPICAL MULTI-FLOW DRAIN
PERMEABLE GRANULAR MATERIAL
MULTI-FLOW PANEL
EXISTING GROUND SURFACE LANDSCAPING OR PERMEABLE WALKWAY
NOT TO SCALE
DISCHARGE
TO LAKE
DISCHARGE
TO LAKE
0 1:500 25
H:\P
RO
J\2
34
1\2
20
0-2
29
9\2
21
4 - R
DF
FG
H
aro
ld
M
an
n R
eg
io
na
l P
ark S
ho
re
lin
e\1
0.0
D
ra
win
gs\1
0.3
M
od
els\2
01
70
30
3 V
-M
OD
L1
.d
wg
, D
RA
IN
C
ON
CE
PT
, 3
/3
/2
01
7 9
:2
0:2
8 A
M