101, 2903 35 Avenue
Vernon, BC V1T 2S7
T: 250.545.0784
F: 250.545.0730
Garry J. Tomporowski, Architect AIBC, B.E.S., MArch.
Kimberly Fuller, Architect AIBC, BFA, BEDS, MArch
The following information supplements and/or supersedes the bid documents issued on October 20th, 2017,
12:00 PM PDT.
This Addendum forms part of the contract documents and is to be read, interpreted, and coordinated
with all other parts. The cost of all contained herein is to be included in the contract sum. The following
revisions supersede the information contained in the original drawings and specifications issued for the
above-named project to the extent referenced and shall become part thereof. Acknowledge receipt of
this Addendum by inserting its number and date on the Tender Form. Failure to do so may subject bidder to
disqualification.
1. Doors & Door hardware: See Drawing A2.2 attached.
Office Doors: D202, 206, 207, 208, 212, 213 changed to lock sets, note on schedule.
- ALL FIRE RATED, ENTRY DOOR CLOSURES TO BE LCN4040XP OR EQUIV.
- ALL CYLINDRICAL LOCKS TO BE SCHLAGE AL SERIES OR EQUIV.
- ALL EXIT DEVICES TO BE 22 SERIES OR EQUIV.
- ALL MEDIUM USE, FIRE RATED CLOSURES 1461 OR EQUIV.
- ALL THRESHOLDS TO BE DRAFT STEEL OR EQUIV.
- ALL WALL STOPS & KICK PLATES TO BE GALLERY HARDWARE OR EQUIV.
2. Windows: Match existing aluminium frame as per specified in drawing A2.2 attached.
3. Ceiling Tile: T-bar Tile - Armstrong Cortega Second Look II - a 24 x 48 with scored line so it
appears like a 2 x 2, or equiv. 2 x 2 lighting proposed in electrical drawings to remain.
4. Millwork specifications: See updated Drawing ID-1 and ID-2 attached.
5. Stairwell treads: See updated Drawing ID-1 and ID-2 attached.
6. Washroom 207,208 mechanical clarification: The upper floor washrooms have been
plumbed, but currently there are no fixtures, finishes and the walls have been framed only.
7. Where is DHWT-2 relocated from? See as-builts, above in area with currently no floor.
8. Are there as‐built drawings for electrical and mechanical? See attached.
9. Stack Vents: The 2 existing stack vents shown on second floor drawings - Contractor to
breakout cost to keep stack vent as-is with additional fin-walls or move as per original
drawings in A2.2.
10. What is the R-value standard for the new roller O/H Doors? Because these O/H doors will be
used for frozen fish storage, the typical R2+ value for a roller O/H door should be sufficient.
11. Will bidders be revealed to the general public? No.
Attachments:
1. Second Floor Plan & Window/Door Schedule 2.2 - Addendum 2 Revision 1 page
2. Interior Design: Finishes Plan ID-1 - Addendum 2 Revision 1 page
3. Interior Design: Elevations & Sections ID-2 - Addendum 2 Revision 1 page
4. As-builts Structural 9 pages
5. As-builts Mechanical 4 pages
6. As-builts Electrical 7 pages
Addendum No.002
FILE: VA1719
# of PAGES: 24
DATE: November 1, 2017 # of Pages
PROJECT: FNHA Office Fit-ups West Kelowna, BC
GLASS WALL
INFILL FLOOR
FRIDGE
EXIT
12' X 9'12'-0" X 9'-0"
13'-2" X 10'-2
13'-2" X 10'-2"
NEW 45 MIN. FIRE
RATED WALL TO
UNDERSIDE OF
STRUCTURE.
ADDENDUM 2
TILE
ELECT.
PANEL
10'-0" X 12'-0"
INFILL FLOOR @ REMOVED
SHUTTER + ENCLOSURE
INFILL FLOOR @ REMOVED
SHUTTER + ENCLOSURE
6'-0" x 7'-0"
NEW RATED EXIT
DOOR + WALL
NEW OPENING IN
EXISTING STAIRWELL
WALL - PATCH + MAKE
GOOD
GLAZED PARTITION
11'-9" X 12'-8"
11'-9" X 10'-11"
11'-9" X 8'-11"
DN
DN 21 R
EX
IS
TIN
G 1
H
OU
R R
AT
IN
G
NEW RATED EXIT
DOOR + WALL
NEW RATED EXIT
DOOR + WALL
ANTI STATIC
RESILIENT
EXISTING STACK
VENT TO REMAIN
& FRAMED
IN-PLACE
EXISTING STACK
VENT TO REMAIN &
FRAMED IN PLACE
201 202
203 204
D201
B C D
1
2
2'
3
3'
5
4
SCALE: 1/4" = 1'-0"1
A2.1SECOND FLOOR PLAN
D203
D205
D202
D207D208
D206
D209
D210
D211
D212
D213 D214 D215
D216
DW
6" x 16" CHASE
ELEVATOR
D204
STAIR 1202
D217
W4
W4
W4
W3
W3
W3
W4
W4 W4
W4
W4
W4
W4
W4
W3
W3
W5
W5
W5
W5
W5
W5
3'-6
"
6'-3 1/4"
4'-1
1"
2A2.1
2A2.1
FURR OUT DUCTING
16'-0
"20
'-0"
20'-0
"12
'-0"
4'-0
"
5'-2
"
4'-11"
24'-8" 24'-0"
4'-0
"
NOTE: FURR OUT ALL DUCTING
T
R
A
V
E
L
D
I
S
T
A
N
C
E
2
0
.
8
0
m
T
R
A
V
E
L
D
IS
T
A
N
C
E
8
.5
6
m
3'-7 3/4"
EXISTING FIRE
RATED WALL
ADDENDUM 2
DO
OR
TAG
DOOR SCHEDULE
D101
D201
D202
D203
D204
D205
D206
D207
D208
D209
D210
D211
DO
OR
INFO
FRA
ME
TYPE
DO
OR
PAN
EL S
IZE
FIRE RATED ENTRY DOOR
DOUBLE WOOD DOOR
WOOD
36" x 84"
NOTES:
FIRE RATED ENTRY DOOR
FIRE RATED ENTRY DOOR
S/C FLUSH DOOR
FIRE RATED ENTRY DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR WOOD
36" x 84"
36" x 84"
36" x 84"
(2) 36" x 84"
36" x 84"
36" x 84"
36" x 84"
36" x 84"
36" x 84"
36" x 84"
36" x 84"
SWIN
G /
HA
ND
RH
RHR
RH
LH
LH
RH
PUSH
/ P
ULL
PASS
AG
E SE
T
LOC
K SE
T
PRIV
AC
Y SE
T
DEA
DBO
LT
CLO
SER
THRE
SHO
LD
WEA
THER
STR
IPPI
NG
WA
LL S
TOP
FLO
OR
STO
P
HARDWARE TYPE:
REFER TO SUPPLIER SPECIFICATIONS FORMODEL AND MANUFACTURER & NOTESINCLUDED W/I THIS SCHEDULE
WOOD
WOOD
WOOD
WOOD
METAL
WOOD
METAL
WOOD
METAL
METAL
D212
D213
D214
D215
D216 WOOD
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
S/C FLUSH DOOR
36" x 84"
36" x 84"
36" x 84"
36" x 84"
36" x 84"
WOOD
WOOD
WOOD
WOOD
LHR
LH
RH
LH
LH
RH
RH
RH
LH
RHR
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
XX
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
45 MINUTE FIRE RATED
45 MINUTE FIRE RATED
45 MINUTE FIRE RATED
45 MINUTE FIRE RATED
DO
OR
TYPE
B
D217 WOOD 36" x 84"
D102 WOOD 36" x 84"
D103 WOODS/C FLUSH DOOR 36" x 84" RHR XXX
CLOSET2 PANEL BI-FOLD
A
B
B
B
D
C
A
A
A
A
A
A
A
A
A
A
A
A
A
S/C FLUSH DOOR RH XX
D104 METALROLLING GARAGE DOOR 9' x 9'E
D105
X X
METALROLLING GARAGE DOOR 9' x 9'E X X MECHANICAL HAND PULLS
MECHANICAL HAND PULLS
X
X
X
PAN
IC H
ARD
WA
RE
X X
- ALL FIRE RATED, ENTRY DOOR CLOSURES TO BELCN4040XP OR EQUIV.
- ALL CYLINDRICAL LOCKS TO BE SCHLAGE AL SERIES OREQUIV.
- ALL EXIT DEVICES TO BE 22 SERIES OR EQUIV.
- ALL MEDIUM USE, FIRE RATED CLOSURES 1461 OR EQUIV.
- ALL MORTIS CASE LOCK TO BE L SERIES SCHLAGE
- ALL THRESHOLDS TO BE DRAFT STEEL OR EQUIV.
- ALL WALL STOPS & KICK PLATES TO BE GALLERYHARDWARE OR EQUIV.
7'-0
"
3'-0" 6'-0"
3'-0
"3'
-0"
2'-0"
7'-0
"
3'-0"
7'-0
"
LINE OF FINISHED FLOOR
DOOR TYPES
LINE OF FINISHED FLOOR
WINDOW TYPES
5'-0
"
8'-3"
2'-6
"
A B C
3'-0"
7'-0
"
D
10'-0"
10'-0
"
E
4'-4"3'-11" 4'-4"
A B
NOTE:
EXTERIOR WINDOWS TO ALIGN WITHEXISTING STUCCO REVEALS AS SHOWNIN ELEVATION DRAWING A3.1
CONTRACTOR TO CONFIRMMEASUREMENTS PRIOR TOCONSTRUCTION
WINDOW TAG
WINDOW SCHEDULE
201
202
203
204
GLAZING TYPE FRAME TYPE SIZE (R/O)
DOUBLE
DOUBLE
DOUBLE
DOUBLE
MATCH EXISTING 60" x 48"
60" x 97"
60" x 97"
60" x 48"
NOTES:INSECT SCREENS ON ALL OPENERS
OPERABLE AWNING
MATCH EXISTING
MATCH EXISTING
MATCH EXISTING
FIXED W/ OPERABLE AWNING
FIXED W/ OPERABLE AWNING
OPERABLE AWNING
TYPE
B
A
A
B
DRAWING NO:
JOB NO:
DRAWN BY:
CHECKED BY:
FILE NO:
SCALE:
DATE:
SEAL
CONSULTANT
REVISIONDATE
Report all errors and omissions to the Architect.
This drawing is an instrument of service and theproperty of TRTA Architecture Ltd. The use of thisdrawing shall be restricted to the original site forwhich it was prepared and publication thereof isexpressly limited to such use.
ALL CONTRACTORS ARE REQUIRED TO PERFORMTHEIR WORK AND SUPPLY THEIR PRODUCTS INCOMPLIANCE WITH ALL BUILDING CODES ANDLAWS OF THE PROVINCE OF BRITISH COLUMBIA
This drawing must not be scaled.
Verify all dimensions and datums prior tocommencement of work.
ARCHITECTURE LTD.#101, 2903 - VERNON BC V1T 2S7T: 250.545.0784F: 250.545.0730email: [email protected] Tomporowski M.Arch,Architect AIBC / Architect, AAA
T·RTA
VA1719
SEPTEMBER 21, 2017
KF, VR
GT
FNHA
OFF
ICE
FIT-
UPS
FIRS
T N
ATIO
NS
HEA
LTH
AUT
HORI
TY
101-
3535
, OLD
OKA
NA
GA
N H
IGHW
AY
WES
T KE
LOW
NA
, BC
1 JUNE 22,2017
ISSUED FORCLIENT REVIEW
2 AUGUST 30,2017 99% REVIEW
3 SEPT. 05,2017 CORRECTIONS
4 SEPT. 08,2017
ISSUED FOR TENDER /CONSTRUCTION
5 SEPT. 21,2017 REVISION 1
6 OCT.30,2017 ADDENDUM 2
VA1719A2
1/4" = 1'-0"
A2.2
SECOND FLOORPLAN & WINDOW /DOOR SCHEDULES
CO
AT
S
COPIER
EXISTING FINISHES TO
REMAIN UNLESS NOTED
OTHERWISE
SHELVING
FRIDGE
COPIER
STAIR 1
105
UP
ELEVATOR
ID2
E1
ID2
E2
ID2
E3
EXISTING FINISHES TO
REMAIN UNLESS NOTED
OTHERWISE
TR1
TR1
WORK
COUNTER
ID2
E7
C1
NEW SECTION OF CARPET TILE-
PROVIDE TRANSITION TO
EXISTING RESILENT
1. THE PAINTING CONTRACTOR IS TO INCLUDE FOR THE PATCHING
AND FILLING OF MINOR MARKS AND DENTS IN EXISTING WALL
SURFACES PRIOR TO PAINTING.
2. PAINTING CONTRACTOR TO SUBMIT DRAW-DOWNS OF ALL PAINT
COLORS/FINISHES, PLASTER FINISH AND COLOR FOR APPROVAL
BY DESIGN CONSULTANT, PRIOR TO COMMENCEMENT OF WORK.
3. FOR ALL DRYWALL PARTITIONS, THE FIRST COAT SHALL BE
PRIMER/SEALER, SECOND AND THIRD COATS SHALL BE ACRYLIC
LATEX EGGSHELL FINISH. SAND LIGHTLY BETWEEN COATS AND
WIPE CLEAN. PAINTER TO EXAMINE ALL SURFACES AND PROVIDE
REPAIR(S) WHERE NECESSARY. UNSATISFACTORY FINISHES
RESULTING FROM IMPROPER PREPARATION WILL BE RECTIFIED
AT PAINTING CONTRACTORS EXPENSE.
4. QUALITY OF WORK SHALL CONFORM TO THE MASTER PAINTERS
AND DECORATOR'S ASSOCIATION STANDARDS FOR PREMIUM
QUALITY OF WORK.
FINISH NOTES
C1
FINISH LEGEND
WALL FINISHES
B1 BASE: 4" Johnsonite black cove base
Extent: Areas with C1, and new walls
CARPET: Bigelow Datum Modular BT284
7879 Basalt (black/brown)
24" x 24" Quarter turn installation
Extent:
C1
P1
P2
PAINT MANUFACTURER GENERAL PAINT
PRODUCT INTERIOR LATEX
COLOUR CL 3104M
COLOUR NAME SEVILLE (BLUE)
FINISH EGGSHELL
P3
PAINT MANUFACTURER DULUX
PRODUCT INTERIOR LATEX
COLOUR #20YY 63/149
COLOUR NAME BRAZIL NUT
FINISH EGGSHELL
PAINT MANUFACTURER GENERAL PAINT
PRODUCT INTERIOR LATEX
COLOUR CLW 1037W
COLOUR NAME STONEY PLAIN
FINISH EGGSHELL
EXTENT WALL, GWB CEILING
CARPET: Bigelow Color Beat (solid)
883 Espresso
24" x 24"
Extent: Accent band
Note:
C2
FLOOR FINISHES
RESILIENT: Marmoleum
Piano 3601 Warm Grey
Extent: Production, washroom, kitchen
R1
PL1
PLASTIC LAMINATE
PL2
LAMINATE MANUFACTURER FORMICA
COLOUR CHALK WHITE S7024T
FINISH TEXTURED
LAMINATE MANUFACTURER ARBORITE
COLOUR RUCHED JUTE R 364 SR
FINISH MATTE
LOCATION: CABINET FACES
PAINT MANUFACTURER General Paint
DOORS PRODUCT INTERIOR LATEX
FRAMES COLOUR CL 3167N
COLOUR NAME Crows Nest (black)
FINISH SEMI GLOSS
P4
STAINLESS STEEL DOUBLE SINK & FAUCET.
Refer to mechanical drawings for specification.
STAINLESS STEEL SINGLE SINK & FAUCET.
Refer to mechanical drawings for specification.
SK1
PLUMBING LEGEND
SK2
EXISTING FINISH: To remain.EX
TRANSITION STRIP:
1
8
" Metal Schluter strip from Carpet to Resilient flooring.
TR1
SW Johnsonite VIRTR-SQ Rubber Tread with Integrated riser for visually
impaired.
Tread – Charcoal 20 with Silver Grey 55 grit tape
Tactile warning pad – Silver Greg 55 squares
Sheet flooring R1
Extent: Stair
FRIDGE
ELEVATOR
ID2
E6
ID2
E4
ID2
E5 TR1
TR1
MICRO-
WAVE
D/W
ACRYLIC
SHOWER
FLASH COVE BASE
FLASH COVE BASE
FLASH COVE BASE
TR1
TR1
TR1
TR1
MATCH
STAIRWELL
PAINT
FINISH
FNHA - KELOWNA
UNIT 101 - 3535 OLD OKANAGAN HIGHWAY
WEST KELOWNA, BC
978 Wellington Drive, North Vancouver, BC, V7K 1K9 T 604 990 7680Gratham/Design/Associates
FINISHES PLAN
ID-1
TRUE NORTH
1'-0" 6"
1 1/2"
1 1/2"
MOUNTING HEIGHT: 5'-4" A.F.F.
SILICONE CAULKING
3
4
" PLYWOOD (PL2)
SHELF
45° MITRE ON
3
4
" PLYWOOD
GABLE. PAINT P1.
1
1
2
" DIA. CHROME
COAT ROD
5'-4"
1
1 2
"
5'-1"
ID2
S1
4'-7
1
4
"
3
1 2
"
FIXED PANEL
PL2
LED STRIP LIGHT
PL1
P1
SK1
PL2
P1
P1
FIXED PANEL
PL1
PL2
FRIDGE
N.I.C.
4"
P1
P1
PL2
B1
SK2
PL2
PL2
FIXED PANEL
PL2
ELECTRICAL PANEL
& CONDUITS.
ID2
S3
ID2
S2
ID2
S4
ID2
S5
ID2
S2
ID2
S6
3'-0"
1'-6"
2'-6"
7'-0"
1'-1
3
4
"
3'-0"
1'-1
3
4
" 1'-1
3
4
" 1'-1
3
4
" 1'-1
3
4
"
2"
1'-11
1
4
" 1'-11
1
2
"
2"
7'-0"
1'-10"
2"
9'-0"
1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1" 1'-1"
8'-10" 4'-3"
3'-0"
1'-6"
2'-6"
7'-0"
1'-2"
1'-2"
1'-7
1 4
"
2'-10"
1'-2
3
4
" 1'-2
3
4
" 1'-2
3
4
"
2'-0"
MICRO
N.I.C.
1'-1
1
2
" 1'-1
1
2
" 1'-1
1
2
" 1'-1
1
2
" 1'-1
1
2
"
FRIDGE
N.I.C.
1'-2"
1'-2"
PL2
PL1
P1
PL2
PL2
PL2
PL1
P1
P1
COPIER
N.I.C.
B1
PL2
ID2
S8
ID2
S9
ID2
S10
ID2
S3
ID2
S11
3'-0"
B1
PL2
4'-6"
2'-6"
7'-0"
1'-8
3
4
" 1'-8
3
4
"
1'-2"
3'-6
1
4
"
6'-0"
3'-4"
1'-6"
2'-6"
3'-5
1
2
"
7'-5
3
4
"
3'-0"
1'-4
1
4
" 1'-4
1
4
"
5'-5
1
2
"
ANGLED WALL
1'-10"
3'-4
1
2
"
1'-11
1
2
"
3'-0"
1'-6"
2'-6"
7'-0"
1'-2
3
4
" 1'-2
3
4
" 1'-2
3
4
" 1'-2
3
4
" 1'-2
3
4
"
6'-3
1
2
"
1'-2
3
4
"1'-2
3
4
"1'-2
3
4
"1'-2
3
4
"1'-2
3
4
"
6'-3
1
2
"
B1
PL1P1
PL2
PL2
ID2
S11
ID2
S3
3'-6"
OPEN FOR
WASTE AND
RECYCLING
5 EQUAL FRONTS
VOID SPACE
FIXED PANEL
EXISTING
CONDUITS
CABINET
SWING DOOR
EXISTING
ELECTRICAL
PANEL
OPEN TO CONCRETE WALL.
SECURE CABINET AS
REQUIRED.
EXISTING CABINET BEYOND
4"
2'-6
1 2
"
2'-1
1
2
"
3'-0"
4"
1'-6"
2"
2'-6"
1'-1"
4"
6'-10"
1'-10"
2"
1'-1"
1
1 2
"
2'-10
1 2
"
2'-1
1
2
"
3'-0"
4"
1'-2"
1'-9
1 4
"
1'-1"
1
1 2
"
1'-2"
1'-4
1
4
"
1'-0
1
4
"
4"
OPEN FOR
UNDER
COUNTER
FRIDGE. N.I.C.
OPEN FOR
MICROWAVE.
N.I.C.
2'-10
1 2
"
2'-1
1
2
"
3'-0"
4"
1
1 2
"
OPEN FOR
DISHWASHER.
REFER TO
MECHANICAL
DRAWINGS.
1'-6"
2"
2'-6"
1'-1"
4"
2'-6
1 2
"
2'-1
1
2
"
3'-0"
4"
1'-2"
1
1 2
"
1'-2"
1'-0
1
4
"
4"
OPEN FOR
MICROWAVE.
N.I.C.
1'-4
1
4
"
4"
2'-6
1 2
"
2'-1
1
2
"
3'-0"
4"
1'-2"
1
1 2
"
1'-2"
1'-0
1
4
"
4"
OPEN FIXED
SHELF
1'-4
1
4
"
4'-2"
2'-6"
2'-0
1
2
"
4"
7'-0"
4"
6
1 2
"
2'-1
1
2
"
3'-0"
4"
1'-6"
2"
2'-6"
1'-1"
1
1 2
"
1'-0"
1'-0"
FIXED PANEL
PL2
PL1
P1
SK1
DISHWASHER
N.I.C.
PL2
P1
ID2
S7
ID2
S2
ID2
S5
3'-0
"1
'-6
"2
'-6
"
7'-0
"
2'-0" 2'-10"
1'-2
3
4
" 1'-2
3
4
" 1'-2
3
4
"
1'-2
1
2
" 1'-2
1
2
" 1'-2
1
2
" 1'-2
1
2
" 1'-2
1
2
" 1'-2
1
2
" 1'-2
1
2
"
8'-7"
FIXED APRON
4"
1'-1
1
3 4
"6
1 2
"
2'-1
1
2
"
3'-0
"
4"
1'-6
"2
"2
'-6
"
1'-1"
4"
2'-6
1 2
"
2'-1
1
2
"
3'-0
"
4"
1'-6
"2
"2
'-6
"
1'-1"
1
1 2
"
3
1 2
"
FNHA - KELOWNA
UNIT 101 - 3535 OLD OKANAGAN HIGHWAY
WEST KELOWNA, BC
978 Wellington Drive, North Vancouver, BC, V7K 1K9 T 604 990 7680Gratham/Design/Associates
ELEVATIONS & SECTIONS
ID2
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
>
> >
>
>
>
>
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
4D ENGINEERINGSTRUCTURALENGINEERS
Er==tt^ - L¿ A¿r¡nD
)l1-'ì i
l, {
..¡
srofiÁô8/sgfrvER
'.ìI :li¡¡,..
ctosto fht $îoltacË
ìlr0t.ô i sËRVÉîl
i3j
4
(s i-
',1.til.1
ii+,,
t05.5,
¡.0$,8
(r)C)-I
O
+F
=z=I
zo
offtcE
roO*h|:z:)
I s.ooari" '-iÊ
6lliå.O
'i
',
uNrr #t 04GROSS FLOOR ARFA:
I,2I B SO,FT,
1".¿{ìitljajll
: j)l)
Stii:l\Ã5ó¡o¡tÂC;r I
üHCE¡:t,¡:;
It -.._. --- -- -- .-. -^ ^-
I
-*1-*{*Ë-ã:-É*.J.
i,iiìi.i:ì:.' : :r.'i¡.:;i:i i:'
:':,:',:, :.1, : r:,:,r j, , -1iìr:,:: ,ii'. ,r.t:ì11. ìr,
i:j¡' ït'r
stclÁGÈc^ô
ril'. r
CTOSED FIt[ SIGìAtrI ros.o:
t.t
$ tt'-¿;'-ã- -* --
UUoo1z
Stor(AÊÊ/SERVfR
rræ-ri
4i!p
"säâo(,3
äuo2
{s}
rS
:r
,ã,.t ll''l.l'
i{}çu
+F.
t-:
l.'r{ì
þr0
i)t\,
11¿'1"
ll\'\.,/
5ËRVEN
c¡8
:s&
fJ
(r.)O
I
(f
Th
tz3I
zo
i,¡r"Jr{}
oFfrc€
i 105-4ì
8aõo
LOO+Ft-z:)
{ Jtlfódu ¡d:
5 ù¡4 l)ftf,s\li
uNlï #t04GROSS FLOOR AREA.
I ,218 S8,FT,
.t
È¡
ruriG cÂ8
off ic€
IiosrI
rit'.Õ''
5a
cs
s
!
R
Ç:
rt\
t.t ilílltl(ii¡'to5-ì
Z\r*=*'"
i;i II
i¡
¡is")- -.'1PROPOSFD TLOOR PiAN - UNIT # ':N4
$Ç(:*: :1.1' . ì't-lGROSS FLOOTì-
i.år'e qtAREA
1 - 1t'nanl
35:jS qd Ckcnogon Avê.. Wesi Kèlo,ì¡/no. S.Ciriy 08, 201 4
sq.fÌ.
aa
{,nli
iì
ir
;:!
(tzE
t?
s*Nfqslcr¡v"f
*¿
&
b'
3.ùô.8
xJlo€Nt05 3
t+ç ì¡,sHft¡¡'
l0&5.¡.3 ll¡û3
zls. 3rã, ¡ere E¡qHUEiTER€TcF^ñ@EorausrEÊHqxroEãtsN,Eoú oFg16ñ ãERv¡ocs
tlr:t i\,: tjtt\an,t4 !i!:
;f;
r;) :+'¡rrà:+ *rYrr,4.;,ã1
l: *ç"er'lM{ü¡**5r:*:
!,i þk $ra-..*tu t,.tu. |ú"et
¡¡ tu:#rá.::Ðåì4¡s,
/¡¡\ ',áea*d(.**:Flr
*¡4.r4,F1
,'5'ì fuïj-Lwoix li[vAitûl{ - wÁstitìöoM\ 31 , t4i{f i;. { :.lr
$t¡i:¡s' râc*w
./ ä\. Mtil.ïlo!îK EtnvÂTtoN .. KncHfi.,¡r !.,/ t l- t;1';i '
rJ|lj ¿*i(À¡ir.í;Ål{ rl,/il
I'TÈ¡rulffi
Lå'ffi
s(þ
ai:':::',
. i:i|. åâri h
,,?'\ s:ÎÊ ÊtÂN / LÖ(:AIÐN prÅN..::.. "
ii*,#¡ß 1ú,15ù)fám¡i , i:tì5 aa s t:npa. l¡;d r}ì'i.'i *q.e!l4s: l
&ffi¡{]1Àeffi l.i!rir)' ;rliijri\ir; r+(!:.iìîi¡ a)
,í#.;*. (\rfl".Ì.rr:. , J. . :
i* t¡,È, rrríl-j..{ïrj i
¡IYt*"?*t:*.,,,.. ¿*rsärï$t,,'.i
' ;)i;;;:'þ;,'tr . .fÞ - wi'-z
,''iù sFfiiclN þF.ïÁl:. - p&?itltotJ wÂti_r¡ rr:e:ì,'::.:.tr
:ajirr::;1,Cl*fRti
:i: I
1::l
t-,,l
?-Íi
'?::
aì
:?<j
Tõ
3
.2
vsU
g
i.Jftrli i í)/jrirs.riv,lii¡cr
a)
s:>llii, . al!:iit:M,i. l
(i'. ¡ ¡{)tra;F d;rr.r;4t
Èxiiä)
i¡iM,tr i lrir: i:Ji,íÌi
*i \ fl4Ail,,¡ i:i..fx)Ê ptÂt¡ . iJfçli trl.l'¡i !L*!¡.r!
' 1.;)
'j,i':i^;
>Í.. Ìi.1.: d di;.t{i¡, l:aì ¡ß.r ,rrl+¡,,i' \ , rî\ll j f.{i I!:, ìi4!1r{r;fi)$1411.tt'],ì¿ .>i
,¡:4 !.rir¡it::¡,: r,1 .:¡
/.!Àit,!! i)'Íþi;ì1,\
-¡¡!t ::: ,.:,¡¡!:d{ ìti.tJiinçr!:ì: .¡),/f (:: t:
lÞ: r\1 !f ta¡fllt¡ 1
rí a,iî{{+r,¡ r¡jxrÀ,i,
si! *-i 1j{_1Ê 1¡ i rií l{
r,..t,í,, ril$ : i.i.1t' a: I
.J¡r"is.i:, 1;1?rii:â a2t
nñiwj*eá¿
r¡
A1
'{*i
jry
r \il;..J
i"--it:Ì.iLÌì........t
fl;-x
1i-"i
'ii
H
Ti'*ìi!;'..r-:i.
ï*t
" r'. rìi:l:i'r{îell c[l"lNG ptÄN - uì.ìjT ic¿
i A. . l)rii :_.1,, : rl\ r': ',
i¡;.".
(3)
(J
cú)
ú)o*F.z:
-oJ/r'ro'7(a)
,,sj ,i
(.}lû:wily i 'jÌ:nuli I
.lf)35 ()d Oto¡lcìÍ¡Jf I Àve., y1Êrst l(.Juyl r¡.¡. ß (:
.ruly Û¡J, 2i| 4
(c)I
(o'¿4' l"
^¡r- IU
l'.til
'tLìe¡
=
a€rJt,ÍU
i
4--
t0
IJ
LiIãø)
u1,.,
t
:?t.idt?..
t: t'
4Uså
l)
Stolr¡¡;¡¡sfpvrlr;1ì
.t îL
¿;ca+7nxîc118cé
lrlt i
)
+ûiO$D f ltt sÍ(,l:¿^cE
t,l5 c,
,.ß,J*at,
lil' t'
)fr r(.:f
to5,¡
ptg¿ØAltUNIT # I C4
?IìOSS FLCOR AR[A;r,2 ìB SQ,rT, h
.Ì thr.
ÞdJttJ
i:i.l : i':¡i ì;:05 :
tP{iOPOS|:D
'-i.OCl? Pl:\N - lli.JlT # 1fi4
I
tft
i.t
.t
f.
i)()
(\,
1
øI
t:ii!¡tìi,llr
:?'
T
¿ð.å
lrt¡t{
¡f
iÍ
rl¿ vr¡ilftfr0! 5
t (r)
t
(J
rtF
.:rI
z
l
i
)l
i.ri\l
J U(ô,t
Ít.,í) ø
li: ¡(;l*l.lr05 3
fdÍ r,Â8
4)',
,i
i
I
! tuouf irl"r5O¡nC
4V
lk";l
T
l¡
øüû¡ô,l
:it ii i vaì€ia, {a$É
,] , {l
'l¡rJ
..ll'()"
t *t";,2ilÚ?
Y
a
:,î
T
I
éj:' ',.}
tl"ì
lri;llí
tti
øI
ScûlB: lr'4' | ù'û*os$ f:t()()lÂnFA
1,210 sc¡.f|.
Bttr ^¿r
ltjrfil¡ rr {
qì:ì)v(.:f¡tt:: tiI
.
t:
1¡
:
zeñ zt5,3çre ËCHUSTEF!Ë:rra*(ôur¡r ¡r-¡r¡r.Jl tatrr1)::.i¡{N,ãFy oËBìri}r e¿tavi.:r:e
Spec's for Tl in unit 104 at Gateway One
ELECTR|CAt
-Plugs as per print
-Standard 3 lamp 2X4lay in t-bar fixtures through out
-optional price to be provided for deep cell parabolic fixtures
-all plugs and switches to be Decora style
-all data and communication by others (tenant)
-security system by others (tenant)
PIU.MBING/HVAC
-HVAC distribution as required by code
-ducting as required for t-bar ceiling complete with diffusers
-ceiling space to be used as return aír plenum
-supply and install complete with ducting one bathroom exhaust fan
-relocate and/or installthermostat as per drawings
-supply and install all rough-in as required for bathroom and kitchen
-supply and install one standard commercial H/C toilet as required by code
-supply and install one wall hung sink and single lever tap as per code for HIC bathrooms
-supply and install standard stainless steel single bowl sink c/w standard single lever tap
-supply and install one 10 gal electric (120v) HWT to be located above the bathroom t-bar
-balance complete HVAC when complete
FTOORING
-front reception area up to front counter to be ceramic tile standard grade
-closed file storage to be pa¡nted concrete
-kitchen area to be ceramic tile
-bathroom to be ceramic tíle
-offices, remainder of reception area, hallway, storage/server area to be glue down carpet 20oz
MrLrwoR(
-kitchen cabinets to be standard over the counter cabinets
-shelving in fíle storage room to be made on site shelving from good one side plywood
-all other millwork by others (tenant)
CEILINGS and WA[[S
-all ceilings to be standard t-bar with 2'x4' grid
-tiles to be standard 2'x4' tile Armstrong or similar
-ceiling to be insulated for sound above tiles
-walls around offices to be insulated for sound
-walls around bathroom to be insulated for sound
DOORS
-doors to be standard 3-0x6-8 paint grade doors solid core doors
-optional price for solid core stain grade door
-door casings to be paint grade flat stock 3 %"
-baseboards to be paint grade flat stock4/,"
PAINTING
-price to include complete painting
-paint colors to be determined by tenant
-optional price to stain doors if stain grade door are used
DEMISING WAttS
-demising wall shall be t hour fired rated consisting of 6" metal 20 gauge stud, 5/8 fire guard both sides
with deflection board at top, taped to paint finish, fire caulked as per building/fire codes.
-opt¡on prices to be provided for lnsulating demising wall one price for R20 insulation and one price forRoxul sound insulation.
-demising wall price to be broken out from Tenant improvement price (separate contract)
AS BUttTS
-as built drawings are to be submitted at completion of job showing any changes to original plans as well
as fixture types, lamp types, paint color chips, etc.
ll
r,..
*h
IË!¡s*å6*I
.