2810 Duniven Circle Amarillo, Texas 806/358-7069
ADDENDUM NO. FOUR
DATE: December 17, 2019 FROM: Lavin Architects TO: Plan Holders of Record PROJECT: Toot’ N Totum
7909 E. I-40 Amarillo, Texas 79118
This Addendum forms a part of the Contract Documents and modifies the original Bidding Documents dated November 27, 2019. Work not specifically deleted, modified, changed or altered by the Addendum should remain in effect as part of the Contract Documents. Acknowledge receipt of this Addendum in the space provided on the Bid Form. Failure to do so may subject Bidder to disqualification. ON THE DRAWINGS: Sheet C3.3 1. Clarification of “Cat Scale” scope of work. Coordinate with Cat Scale installers to verify scope of
work. For bidding purposes use civil points “Scale 4057”, “Scale 4058”, “Scale 4059”, and “Scale 4060” on sheet C3.3 as your construction limits.
Sheet C5.1 See attached sheet C5.1 for revised details. Sheet C7.1 See attached sheet C7.1 for revised details Sheet A1.2 1. Provide alternate price to demolish the existing chain link fence at west and north side of trucker
parking and provide new fence as per note 37. 2. The dog park, playground, curbing, turf, fall protection, fence, etc. will be by owner. GC scope to
be concrete sidewalks, patio concrete, and installing the owner furnished outdoor furniture. 3. Provide additional concrete sidewalk from existing accessible ramp to new sidewalk. Sidewalk to
have no greater slope than 5% in direction of travel and no cross slope greater than 2%. See attached drawing.
4. Delete 12” x 12” drains at the diesel canopy (note 38). Sheet A1.3 1. Refer to detail 6/A1.3 for sidewalks. Sheet A2.1 1. Interior Elevations for Corridor 139 & Corridor 143 to be similar to Interior Elevation 15/A6.2. 2. Add “Door buzzer on exterior doors with an on/off switch located at Cashier 102 and Trucker
Cashier 124. Verify with owner exact location of the switches” Sheet A2.2 1. See attached floor plan for raised platform at Cashier 102. 2. Equipment Schedule #74 change to Bobrick B-169-2436. See A6.2-R & electrical addendum #4 for
quantities. 3. Equipment Schedule #75 change to Bobrick B-169-3040. See A6.2-R & electrical addendum #4 for
quantities. Sheet A2.4 1. Wall Schedule Clarification. All interior walls (stud, gyp. bd., insulation) to deck. At exposed areas
all walls to be scribed inside of flutes at deck.
2810 Duniven Circle Amarillo, Texas 806/358-7069
ADDENDUM NO. FOUR
Sheet A2.5 1. Omit Room Finish Schedule Notes 3 & 7 where “Silikal” is to be provided. Sheet A3.1 1. Spandrel panel to be bronze to match the glazing. 2. Doors 127C, 128C, 138D, 145A & 145H to be 3’-0” wide in lieu of 2’-10” wide to meet TAS & ADA. Sheet A4.1 1. Exterior elevations to be “Scale 1/8” = 1’-0” in lieu of 1/4” = 1’-0”. Sheet A5.1 1. Delete note that states “Smooth form finish at exterior grade beam 12” below brick pocket”.
Grade Beams can be Earth formed. Sheet A6.2 1. See attached reissued sheet for revised restroom layout & interior elevations. Sheet A6.4 1. Ensure the faucet lever is within 17” of the face of counter for detail 15/A6.4 to meet TAS & ADA. Sheet A8.1 1. See attached reissued sheet with revised lighting layouts in restrooms. Sheet S5.04 1. See attached revised detail #4 Civil 1. See attached sheet. Structural 1. See attached sheet. Mechanical 1. See attached sheet. Electrical 1. See attached sheet. END OF ADDENDUM NO. 1
T.O.S. EL.-SEE ARCH'L
B.O.S. EL.-SEE PLAN
T.O.S. EL.-SEE PLAN
JOIST UPLIFTBRIDGING ASREQ'D. BY JOISTSUPPLIER
MASONRY,EIFS OR MTL. PANEL -SEE ARCH'L
L3x3x1/4 CONT.
C.F.S. STUD W/ DEFLECTION TRACK @ TOP (NOT BY JQ)
STL. BEAM -SEE PLAN
STL. JOIST -SEE PLAN
HSS3x3x3/16 @ 32" O.C.
1'-6
"2'-2
1/2
"
PL. 1/4"x12" CONT. W/ 3/4"Ø HOLES @ 32" O.C.
SE
E P
LA
N
SEE ARCH'L
AWNING BY OTHERS-SEE ARCH'L
STL. ROOF DECK -SEE STRUCTL. NOTES
HSS3x3x1/4 AT EA VERT. W/ 1/2" CAP PLATE. 5/8"Ø THREADED STUD TO SHOP WELD TO CAP PLATE
TYP.
TYP.
SEE FOR ATTACHMENT AT ENDS TO COLUMN
14/S5.02
FOR ADDN'L INFO.SEE 7/S5.03
4
4
JQ ENGINEERING, LLP1204 BROADWAY, SUITE 204806.392.9180
LUBBOCK, TEXAS 79401
TBPE FIRM F-1294
JQENG.COM
PROJECT NO:
REF.
CLIENT
PROJECT
REV. DATE SHEET
shaping the built environment
BRIAN J. ROBERTSON
108844
12/17/2019
Toot 'N Totum, 7909 E. I-40, Amarillo, TX
Lavin Associates, Inc.
12/17/19 SSK-01ADDENDUM #4S5.043190114
SCALE: 3/4" = 1'-0"4 SECTION AT CANOPY
Page 1 of 1
Brown Consulting Engineers, Inc.
3505 Olsen • Suite 110 (806) 354-0141
Amarillo, Texas 79109 Fax: (806) 354-0142
December 16, 2019 BCE, Inc. Project #21927
Memo to: Richard Sims, Lavin Associates, Inc.
From: Seth A. McClellan, P.E.
Subject: A New Building for Toot ‘N’ Totum Addendum #4 Please forward the following addendum to the contractor for inclusion in the project.
PLUMBING Item 1: Specification Section 15410: Add the following paragraph:
2.20 COMPRESSED AIR PIPING
A. Steel Pipe: ASTM A53 Schedule 40 black. 1. Fittings: ASME B16.3, malleable iron, or ASTM A234/A234M, forged steel
welding type. 2. Joints: NFPA 54, threaded
2.21 COMPRESSED AIR BALL VALVES
A. Manufacturers: 1. Nibco Model T-585-70-66 2. Milwaukee #BA-400S
B. Construction, 2 inches and smaller: MSS SP-110, Class 150, 600 psi CWP, bronze, two piece body, stainless steel, full port, teflon seats and stuffing box ring, blow-out proof stainless steel stem, lever handle threaded ends.
End of Addendum #4
December 16, 2019 Texas Registered Engineering Firm F-683
P. O. Box 3800
121 S. Bonham
Amarillo, TX 79116
806.372.2904
fax 806.371.0424
Daniel McCracken, P.E. Michael Ferry, Electrical Designer
Ryan Miller
Lavin Architects
Amarillo, Tx
12/17/2019
Re: Toot-N-Totum Lakeside Electrical Addendum #4
Dear Ryan;
Please note the following electrical items for Toot-N-Totum Lakeside Electrical Addendum #4:
1. Add power and sleeves for a CAT Scale. See the attached SK1.
2. Change the 2x2 troffers in certain restrooms to recessed downlights
and add combination Type M1 and M2 mirror lights over the
vanities where shown. See the attached SK1. The Type M1 mirror
lights are Bobrick B169-2436 mirrors. Type M2 Mirror Lights are
Bobrick B169-3040. Connect the Type M1 and M2 lights to the rest
of the lighting in the room.
3. Pole base detail on Sheet E-0.0. The rod ties shall be every 12” the
entire height of the pole base.
4. Install flush single gang junction boxes at every exterior camera
location. Heights of cameras will vary based on the locations.
Cameras for drive up locations will be 4 feet. Verify all heights. Stub a ¾” conduit to accessible
ceiling.
5. For cameras in door mullions, feed down the mullion with Cat 5e cable to a height of 5’ and
penetrate the mullion with the cable.
6. Sheet E-2.0 – Keyed Note 25 – Add a 2” conduit in the floor from the TV rack to the IT room.
7. Add Item 49 to the C-Store Equipment Schedule for Cameras.
Sincerely,
Spectrum Engineering
CAT
PICK-U
PW
IND
OW
KEEP CLEAR
KEEP CLEAR
JJJ
J
JJ
SPSP
SP
SP
SP
SP
SP
SP
M
M
M
M
M
M
MM
M
M M
MM
OS
OS
M M
M M
M
SP
OS
G-37,39
G-38,40
G-41,43
G-42,44
AA29
AA29 AA29
AA28 AA28
HA-6,8
HB-6,8
2-#12, 1-#12 G THE ENTIRE LENGTH OF THE CIRCUIT
2-#8, 1-#10 G
2-#8, 1-#10 G
2-#8, 1-#10 G
2-#8, 1-#10 G
DRIVE UP SIGN
8
8
23
24
11
G2-5,7 G2-6,82-#8, 1-#10 G2-#8, 1-#10 G
15
3
14
26
26 26 26 26 26 26 26 26 26 26
2626
27
27 27
27
27
26
TWO 1-1/2" C EMPTY, ONE 1" CONDUIT WITH 9-#10, ONE-1" CONDUIT WITH 7-#10 FROM PANEL LA2 TO THE CAT SCALE. SEE KEYED NOTE 28
TWO 1-1/2" EMPTY FROM FUEL DESK TO CAT SCALE
11
28
28
28
1
28. POWER AND SLEEVES FOR CAT SCALES. INSTALL TWO 1-1/2" CONDUITS FROM THE FUEL DESK AND TWO 1-1/2" CONDUITS FROM PANEL LA2 FOR CAT SCALE INSTALLER LOW VOLTAGE CONDUITS. INSTALL 8-#10 STRANDED, 1-#10 STRANDED GROUND IN 1" CONDUIT FROM FOUR 20/1 CIRCUIT BREAKERS (USED FROM THE SPARES) IN PANEL LA2 FOR SCALE POWER. FEED THE FUEL DESK EQUIPMENT WITH 3-#10 FROM A CIRCUIT BREAKER IN PANEL LA. INSTALL 6-#10, 1-#10 GROUND IN ANOTHER 1" FOR THE SIGN, INTERCOM, AND CAMERA LOCATED AT THE SCALE.
SITE PLAN KEYED NOTES ADDENDUM 4
KL8 KL8
KL8KL8
KL8 KL8
KL1
KL1
KL1EM
KL1EM
KL1
KL1
KL1
KL1
KL1
KL8 KL8
KL8
KL8
KL8
KL1 KL1
KL1
AL30
AL30EM
AL30
AL30EM
AL30
AL30EMAL30EM
AL30
AL30
AL30
AL30
KL1
KL1KL1KL1
KL1
KL1
KL1
KL1
KL1
KL1
KL1
KL1
KL1
KL1EM KL1KL1
KL1 KL1
KL1 KL1
KL1EMKL1KL1
LA-36
KL1 KL1 KL1
KL1
1313
13
13
KL1
KL1
KL1
KL1 KL1
KL1 KL1
KL1
KL1
KL1KL1
1
1
M1
M1
M1
M1
M1 M1 M1
M2
KL1
KL1
KL1
KL1
KL1 KL1
KL1
KL1
KL1 KL1KL1
13
13
KL1
KL1
KL1
KL1 KL1
KL1
KL1
KL1
KL1
KL1 KL1
KL1 KL1
1
M2
M1 M1 M1
KL1
O
N
DANIEL G. McCRACKEN
52857EO R
O
G
I
I
F
SE
S
S T A
RP
T E
EDE NIRE
L E N GS T
A
E
TF
SAE X
R
121 South BonhamAmarillo, TX 79106Phone: 806.372.2904Fax: 806.371.0424
Email: [email protected]
SPECTRUM ENGINEERING
Scale
Project numberDateDrawn byChecked by
EXPIRES 12/31/2019THE SEAL APPEARING ON THIS
DOCUMENTWAS AUTHORIZED BY
DANIEL G. MCCRACKEN P.E. ON 12/16/2019
REVISION 1 - 12/16/20191
As indicated
12/1
7/20
19 9
:14:
50 A
M
SK-1ADDENDUM 4
2013-24TOOT-N-TOTUM
Addendum 412/16/2019AuthorChecker
1" = 40'-0"1 Site Plan Addendum 4
1/8" = 1'-0"3 Addendum 4 Lighting N
1/8" = 1'-0"4 Addendum 4 Lighting S