© 2015 by Honeywell International Inc. All rights reserved.
Agenda
• ONYX Series
• VeriFire Tools
• Intelligent FAAST
• SWIFT 2.0
• Emergency Communications/Voice
• Discontinued Products
• IntelliQuad Replacement Program
• IPGSM-4G(C)
© 2015 by Honeywell International Inc. All rights reserved.
Firmware Version 24 (Release in October)
• NFS-320 and NFS2-640
- Supports Intelligent FAAST XT and XS
- Supports SWIFT 2.0 (Relay Module)
- Supervisory Type Code for Acclimate (photo element)
Select latching or tracking for the photo element (global setting)
- Ability to set the CO element of an FCO-851 for latching or
tracking (global setting)
- Ability to set alarm verification time up to 240 seconds
Requires AHJ approval
- Requires VeriFire Tools Version 9.00
© 2015 by Honeywell International Inc. All rights reserved.
Firmware Version 24 (Release in October)
• NFS2-3030
- Supports Intelligent FAAST XT and XS
- Supports SWIFT 2.0 (Relay Module)
- Supervisory Type Code for Acclimate (photo element)
Select latching or tracking for the photo element (global setting)
- Ability to set the CO element of an FCO-851 for latching or
tracking (global setting)
- Ability to set alarm verification time up to 240 seconds (requires AHJ
approval)
- Includes a Tracking Alarm Type Code for Monitor Modules
- Includes the ability for the NFS2-3030 in Network Display Mode
to display the active pipe(s) of the VESDA VLS detector
Requires the VESDA-HLI-GW with firmware version 3.22.132 or
higher
- Improved labeling to better support SCS weekly test
- Requires VeriFire Tools Version 9.00
© 2015 by Honeywell International Inc. All rights reserved.
Firmware Version 24 (Release in October)
• NCA-2 Supports
- SWIFT 2.0 (Relay Module)
- Supervisory Type Code for Acclimate (photo element)
Select latching or tracking for the photo element (global setting) at
the FACP
- Improved labeling to better support SCS weekly test
- Requires VeriFire Tools Version 9.00
© 2015 by Honeywell International Inc. All rights reserved.
ONYX Series Summary
In Both New and Existing Applications!
• Latest panels and firmware enable you to offer your customers:
- SLC Connected Aspiration with Intelligent FAAST
- SWIFT Wireless, now with output relay
- Expanded Type Codes and panel settings for more flexible
programming
- Detection and Advanced Detection to meet the needs of any
application
© 2015 by Honeywell International Inc. All rights reserved.
VeriFire Tools Version 9.00 Features
• Surface Pro 3 Tablet Support!
• Auto Populate of the UDACT-2s assigned points based on the Type
Code labels of host panel
- NFS-320, NFS2-640, NFS2-3030 and NCA-2
• Importing of Detector and Module Labels from Excel
- Custom and Extended labels, General Zone labels, and Custom
Action Messages
• Enhanced DVC Copy and Paste functionality
- Copy many, paste many
- Copy and Paste across DVCs
© 2015 by Honeywell International Inc. All rights reserved.
VeriFire Tools Version 9.00 Features
• Improved Software Version Statistics
• Corrects issues pertaining to:
- Class A riser to control modules
- DVC KD Programming with Remote General Zones
- Amplifier Remote Microphone programming issue
- Fixed migration and creation of NFPA Templates from Database to a
file format
• A ‘What’s New In This Release’ presentation located in the Backstage
section of VeriFire Tools
- Business Partners should review this presentation for additional details
on the above referenced features and for information on
enhancements and issues resolved in this version and previous
releases
© 2015 by Honeywell International Inc. All rights reserved.
Auto Populate of UDACT-2
• Simplifies the work of programming the UDACT-2’s assigned points with
the correct function type (required for the Central Station to receive correct
operational reports)
• Each point’s function type is determined by the Type Code assignment of
the host panel input device that is pre-programmed and associated with this
point
• There is a unique correspondence between these Type Codes and the
UDACT-2’s function type. For instance:
- If a NFS2-3030 has a heat detector programmed into one of its loops then the
UDACT2’s corresponding point will need to have its function programmed to
“Heat Detector”.
- If it’s a Security module then the UDACT2’s corresponding point will need a
function of “Burglary”.
• This feature will automatically determine and program this correct function
for each UDACT-2’s point, when possible, eliminating manual intervention.
© 2015 by Honeywell International Inc. All rights reserved.
Auto Populate of the UDACT-2
• NFS2-303 Demonstration
Starting with no UDACT
programming in the panel.Then install a UDACT type
Annunciator. Annunciators
points will be mapped after
SLC devices are installed.
Then install your Detectors
customized to particular type
codes.
Then install your Modules
customized to particular type
codes.
Now map your devices to
the individual UDACT ACS
points.
Now switching to the UDACT-
2 programming service: The
default function type for all
ACS points is “Fire Alarm”.
After the “Auto Populate”
button is clicked and you
confirm by selecting “OK” to
the popup, these points will
be automatically programmed
without manual effort.
© 2015 by Honeywell International Inc. All rights reserved.
Surface Pro 3 tablet support
• Support is currently limited to factory Default Settings of:
- Resolution: 2160 x 1440
- Display: Large 150
• Surface Pro Type Cover is recommended for a better
data entry experience:
• Supports the common gestures for touch enabled
devices:
• Surface Pen provides additional level of granularity for
selections
© 2015 by Honeywell International Inc. All rights reserved.
Surface Pro 3 tablet support
• We have provided a user preference setting to improve tactile area
- Labeled “Enable Touch Support”
- Provides slightly larger than the normal control size for easy finger
interaction on a touch monitor
© 2015 by Honeywell International Inc. All rights reserved.
Surface Pro 3 tablet support (continued)
15
- Before enabling selection:- After enabling selection:
© 2015 by Honeywell International Inc. All rights reserved.
VeriFire Tools Summary
•Programming Efficiency - Improved copy and past functionality
- Import labels from Excel
- Auto Populate UDACT-2 point assignments
- Copy and paste across DVCs
• Surface Pro 3 Tablet support
- Alleviate the need for technicians to carry laptops
• What’s new in this Release
- Detailed information on enhancements
© 2015 by Honeywell International Inc. All rights reserved.
FAAST XS Added to The Line Up
Enables you to better serve the needs of smaller applications!
• FSA-5000 (Intelligent FAAST XS)
- Same features as all FAAST series products
- 3-speed fan, configurable
- 3 alarm thresholds (Alert, Fire 1 and Fire 2)
- 5 SLC addresses
1st address associated with Alert
2nd, 3rd and 4th addresses associated with Fire 1
- To prevent confusion don’t associate all 3 addresses to Fire 1
(still uses all 5 addresses)
5th address associated with Fire 2
© 2015 by Honeywell International Inc. All rights reserved.
FAAST Features
• Uses the same FAAST nuisance rejection and advanced detection
technology as the current offerings
- Patented particle separator, replaceable filter and dual source optical
smoke detection
© 2015 by Honeywell International Inc. All rights reserved.
FAAST Features
• Connects directly to the SLC Loop of ONYX series panels- No modules or High Level Interface required
Sits on SLC with
other standard devices
SPOT
PULL
STATION
SPOT PULL
STATION
(FAAST XS)PANELSFSA-5000
ONYX 9th FACP version
23 or higher
© 2015 by Honeywell International Inc. All rights reserved.
FAAST Features
• Includes built-in email notification option, and monitoring and
configuration via Modbus/TCP protocol over Ethernet
© 2015 by Honeywell International Inc. All rights reserved.
FAAST SeriesFAAST XS FAAST XM FAAST XT
Model
Number
FSA-5000 (Intelligent)
7100X (Conventional)
FSA-8000 (Intelligent)
8100 (Conventional)
FSA-20000 (Intelligent)
9400X (Conventional)
Agency
Listings
UL, ULC, FM,
CSIRO, ACTIVFIRE,
CNTC, VdS, CE, KFI,
CSFM
(Class I/Div II)
UL, ULC, FM, CSIRO,
ACTIVFIRE, CNTC, VdS,
CE, KFI, CSFM
(Class I/Div II)
UL, ULC, FM, CSIRO,
ACTIVFIRE, CNTC,
VdS, CE, KFI, CSFM
(Class I/Div II)
Coverage
Area
Up to 5,000 sqft
(743 sq m)Up to 8,000 sqft (743 sq m)
28,800 sqft (2,676 sq
m)
Max
Single
Pipe
180 ft 262 ft 400 ft
Fan
Speed
User configurable 3
speed fanSingle Speed
User configurable 3
speed fan
Software PipeIQ 2.2.7 PipeIQ 2.2.7 PipeIQ 2.2.7
© 2015 by Honeywell International Inc. All rights reserved.
Applications
• Mission Critical
- Computer & data processing
- Telecommunications
- High-tech manufacturing
© 2015 by Honeywell International Inc. All rights reserved.
FAAST Summary: Simplicity + Integration
• Early Warning Aspiration Detection- Advanced nuisance alarm rejection
• Patented 3 stage filtration allows use in the
harshest environments- Suited For a Wide Variety of Applications
Not JUST Mission Critical
• Integration options include:- Direct SLC connection, no additional hardware required
- Modbus on board
- Ethernet via web browser and email server
© 2015 by Honeywell International Inc. All rights reserved.
NOTIFIER’s SWIFT Wireless Overview
For life safety and property protection in challenging environments
• Smart Wireless Integrated Fire Technology
- Patented proprietary wireless Mesh protocol
© 2015 by Honeywell International Inc. All rights reserved.
What’s new with SWIFT 2.0 – Relay Module
• Applications- Activate remote power supplies, elevator recall, door holders HVAC, etc.
FW-RM
• Equivalent contact ratings to the wired relay
- 15 to 32 VDC, Single Pole Double Throw
• Equivalent battery specifications to all wireless
devices
- UL listed 2 years of battery life
- Latching relay
- A relay in the “off-normal” or “active” position will
draw more power due to the LED drawing more
power
- Use the normally closed or normally open contacts
for the standby conditions
• New FlashScan Type ID
- Wireless Relay (RF RELAY)
- Requires Panel Firmware 24
© 2015 by Honeywell International Inc. All rights reserved.
Wireless Relay Limitations
• One relay module per output device
• Two relay modules in parallel to activate multiple
devices
• When wireless relay module is in use
- Total module device count must be limited to 109 modules per
loop
- Includes wired and wireless modules on the same loop
- Module address range must be within 1-109
© 2015 by Honeywell International Inc. All rights reserved.
Wireless Relay Limitations
• Emergency control function interface
- Wiring within 3’ or 20’ non-metallic conduit
NFPA 72 requirement 21.2.4
- Other applications not distance limited
• Activation of wireless relay from a wireless module input
source must be in the same mesh
- Does not apply to wireless detectors and does not apply to
wired input sources
• Not listed for Releasing Service use
- Use onboard NACs or FCM-1-REL
© 2015 by Honeywell International Inc. All rights reserved.
What’s new with SWIFT 2.0
• Trouble threshold improved from -50dBm to -55dBm
- Upgrade existing systems can resolve borderline weak link
troubles
- Additional 5dBm may mean 5’-15’ improvement (results will
vary)
• Cyber Security Enhancements
- Stronger password for SWIFT
8 alphanumeric / special characters
User required to change the “default” password
© 2015 by Honeywell International Inc. All rights reserved.
What’s new with SWIFT 2.0
• More detailed battery information in the communicator
window of SWIFT Tools
• Popup includes SLC address for consistency
© 2015 by Honeywell International Inc. All rights reserved.
SWIFT version 1.0 vs 2.0
• Entire Mesh Network must be at same version
- Cannot not mix version 1.0 with 2.0
• When Relay Module is being used Mesh Network must be 2.0
• Devices can be upgraded/downgraded individually
- Upgrade/downgrade instructions are included within SWIFT Gateway
Manual and with the SWIFT firmware available on the ESD site
© 2015 by Honeywell International Inc. All rights reserved.
Targeted Applications
• Difficult to wire
- Impossible or expensive to wire
• Restricted Access
- Hazardous materials or security concerns
• Aesthetic Concerns
- Conduit or wire mold not acceptable
• Temporary Occupancies
- Classrooms or construction sites
• Renovations
- Reduce fire watches on floor by floor
renovations
© 2015 by Honeywell International Inc. All rights reserved.
DVC
• DVC version 7.40.2
- Provides improved message timing
• DAA2 version1.90.1 and DAX version 1.30.1
- Corrects issue with amp troubles when using the 520 Hz low frequency
tone
• DS-DB version1.50.1
- Corrects issue with EVAC circuits not resounding EVAC message after
a manual page or on fire alarm resound after silence
© 2015 by Honeywell International Inc. All rights reserved.
DVC
• Low Frequency Documentation
- DVC and Digital Audio Amplifier Manuals address DVC and compatible
amplifiers
- Device Compatibility Document addresses compatible System Sensor
Speakers and Speaker-Strobes
© 2015 by Honeywell International Inc. All rights reserved.
FirstCommand NFC-50/100DA
• Distributed Amplifier with Backup capability
- Meet specs that require backup capability
- Offer a system with added survivability
- Includes two amplifiers and 8 speaker circuits
- 25 volt or 70 volt operation (field selectable)
- Supports multiple configurations
NFC-50/100DA NFC-BDA-BUNFC-50/100DA
Expands the ECS/Voice Evacuation Capability of FirstCommand
© 2015 by Honeywell International Inc. All rights reserved.
FirstCommand NFC-50/100DA
- NFC-50/100DA Configurations
50 watt primary/50 watt backup (NFC-50/100DA)
100 watt primary (NFC-50/100DA)
100 watt primary/50 watt backup
- Requires optional NFC-BDA-BU
- Will backup one of the two NFC-50/100DA built-in amps
NFC-BDA-BUNFC-50/100DA
© 2015 by Honeywell International Inc. All rights reserved.
FirstCommand Low Frequency
• Low Frequency Approved
- NFC-50/100
- NFC-50/100DA
Referenced in FirstCommand Manual
- SpectrAlert Advance indoor high fidelity speakers and speaker strobes
Referenced in Device Compatibility Document
The NFC-50DA and NFC-125DA are not capable of complying with low frequency requirements
© 2015 by Honeywell International Inc. All rights reserved.
Quam Speakers (Compatibility Tested with NOTIFIER)
• Ceiling tile replacement drop-in speakers
• UL 1480 listed for fire applications
• Aesthetically pleasing
• Quality sound
• No junction box required
• Will be added to our DCD
- (Device Compatibility Document)
• Two models
- UL22/25 (25 V)
- UL22/70 (70 V)
4w, 2w, 1w, 0.5w, 0.25 settings
Contacted Quam for samples after learning that ESDs were using/interested in using
© 2015 by Honeywell International Inc. All rights reserved.
Addressable Ionization Detectors (FSI-851/A and NI-
100/A)• FSI-851(A) and NI-100(A) discontinued as of July 2015
- Refer to the discontinuation notice and System Sensor Flyer for
suggested alternatives https://esd.notifier.com/en-us/support/productbulletins/Pages/2015-05-04-Ion-Detector-Discontinued.aspx
© 2015 by Honeywell International Inc. All rights reserved.
PRN-6
• PRN-6 printer replaced with PRN-7
- For applications that require a hardcopy printout
- Time stamp of each event reported
- Uses standard 9” x 11” tractor-feed fan-fold paper
- 80 columns of data, 10 characters per inch
- Refer to announcement on ESD site for details
https://esd.notifier.com/en-
us/support/productbulletins/Documents/PRN7_Product%20Announcement_ENUS.pdf
PRN-7
© 2015 by Honeywell International Inc. All rights reserved.
IntelliQuad Replacement(FCO-851 and FSC-851)
© 2015 by Honeywell International Inc. All rights reserved.
FCO-851(A) and FSC-851(A) Replacement
• These detectors remain one of the worlds most accurate
fire and fire/CO detectors with superior nuisance
rejection
• Proven IntelliQuad technology uses input from four
sensing elements – photoelectric, thermal, infrared and
carbon monoxide with advanced algorithms to identify
true fire conditions
• As with all Carbon Monoxide sensors the CO cell within
these detectors will reach their end of life 6 years after
initial installation
IntelliQuad/FCS-851 IntelliQuad PLUS (FCO-851) w/B200S
© 2015 by Honeywell International Inc. All rights reserved.
FCO-851 and FSC-851 Replacement
• Replacement Detectors are available at 34% discount
off of current Net Price. Use the following procedure to
get replacement detectors at the discounted rate- Send an email to your Regional Sales Manager (RSM) requesting the
discounted price for replacement detectors.
List the project site
Attach a dedicated purchase order (PO) for the replacement detectors. Do
not include any other equipment on this PO. Replacement detectors
cannot be ordered via eCommerce
- If approved, your RSM will forward the PO to Customer Service and
copy you. If there are any questions, your RSM will contact you
© 2015 by Honeywell International Inc. All rights reserved.
IPGSM-4G(C) Overview
Traditional POTS lines becoming extinct
• Supports IP, 4G, 3G, 2G (cellular)
• Three field configurable modes
- IP Primary (GSM backup)
- GSM only
- IP only
• NFPA 72 compliant
- Other transmission technologies
• Can be used with any FACP/Dialer with Contact ID
© 2015 by Honeywell International Inc. All rights reserved.
IPGSM-4G Benefits
Deliver solutions and cost savings to your customers
• Monitor panels/equipment previously not monitored
- Using GSM technology
• Minimal setup
- Connects directly to Digital Alarm Communicator Transmitter (DACT)
• Eliminate costly and troublesome phone lines
- Below data from a real application
Communicator Quantity Monthly Fee Yearly Fee
DACT 2 phone lines per building$90
(x 17 lines) $18,360
IPGSM-4G 17 units$35
(monitoring fee) $7,140
© 2015 by Honeywell International Inc. All rights reserved.
IPGSM-4G(C) Update
• Two Digit Group Code
- IPGSM-4G(C) operating with firmware version 3.02 or higher
support the two-digit group code in Contact ID
Version 3.02 released in May
• IPGSM-4G(C) Product Bulletin
- A low probability anomaly identified that could cause the radio
to enter into failure state
Potentially affected units were manufactured between November
3, 2014 and July 30, 2015, dates codes X307-Y211
- Refer to Product Bulletin and/or contact Technical Service for
assistance https://esd.notifier.com/en-us/support/productbulletins/Pages/2015-09-08_IPGSM-
4G_FirmwareUpdate.aspx
© 2015 by Honeywell International Inc. All rights reserved.
Summary
• ONYX Series
- The heart of a life safety system
• VeriFire Tools
- Programming Efficiency, Surface Pro 3 Tablet support
• Intelligent FAAST
- SLC connected aspiration detection for any environment
• SWIFT 2.0
- Life safety/property protection in challenging applications
• Emergency Communications/Voice
- For ECS, MNS and meeting Low Frequency requirements