Advanced Clinical Parameters and Technology

XN-Series™ Automated Hematology Analyzers

Count on Sysmex to do more thanjust talk about automation.

To see all that Sysmex delivers, andwhat customers are saying, go to

www.sysmex.com/delivers

Page 2: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

Technology that Advances Accuracy, Specificity and Productivity

New fluorescent dyes increase cellular specificity:

• Get the precision and accuracy you expect from Sysmex:

– Identifies NRBCs directly in the white blood cell channel and eliminates the need for WBC count corrections

– Enhances and optimizes flagging for abnormal cells, which increases the number of reportable differentials

– Provides body fluid counts, including a two-part differential

• Leverage a second method of platelet analysis in the new PLT-F channel:

– Improves platelet analysis on challenging specimens by using a platelet-specific fluorescent dye

– Provides Immature Platelet Fraction (IPF) results for investigation of thrombocytopenia in conjunction with other available clinical information

– Reduces manual intervention through user-definable rerun and reflex decision rules

Laser Beam(Wavelength = 633nm)

Dichroic Mirror Cell inside structure information

Cell size information

DNA/RNA informationSide Fluorescent Light

Side Scattered Light

Forward Scattered Light

Laser DiodeCollimator Lens

Dichroic Mirror

Spectrum Filter

AvalanchePhotodiode

Photodiode

Photodiode

Beam Stopper

Condenser LensCondenser Lens

Flow Cell

Page 3: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

Cell Analysis in Hematology is Different Now The XN-Series Hematology Systems are advancing hematology technology with the introduction of new cell analysis channels. A robust system of new cell-specific lyses and fluorescent dyes evaluates cells more thoroughly than ever before.

The XN-Series analyzers are designed to be a step above hematology analyzers of the past. Areas of enhancement include:

• Accuracy and precision of low WBC counts

• Accuracy and precision of low platelet counts

• Direct counting and reporting of NRBCs

• Increased reportability of WBC differentials at very low counts

FSC = Forward Scattered LightSFL = Side Fluorescent Light

Technology:

Fluorescent Flow Cytometry with polymethine dye for nucleic acids, cell-specific lyse

Parameters reported:

WBC count, BASO#, BASO%, NRBC#, NRBC%

Reagents:

Lysercell® WNR and Fluorocell® WNR

The New WNR ChannelNucleated Red Blood Cell Assessment is Standard with Every CBC

It’s the height of efficiency. Nucleated red cells are identified and counted in this new channel along with white cells. No need for a special reagent or sample prep, and no mathematical corrections. Virtually eliminates interference from lipids or lyse-resistant RBCs. Now you can have accurate WBC counts the first time, every time—even in the presence of NRBCs.

In the WNR Channel, the analyzer measures side fluorescence and forward scatter. Side fluorescence measures the nucleic acid content to identify NRBCs in the same channel in which white cells are counted. Forward scatter measures cell size.

Page 4: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

The New WDF ChannelImmature Granulocytes (IG) are Standard with Every WBC Diff

The new WDF channel improves reporting accuracy and precision for low WBC counts (<500 cells). That’s because the XN-Series WDF channel includes a Low WBC mode which triples the number of cells counted, giving you a differential on every low WBC count. In short, the WDF channel increases the number of reportable WBC and differential results.

Fewer vote-outs means more reportable diffs. Sysmex has improved the sensitivity and specificity of the six-part diff by developing a new method for discriminating monocytes, lymphocytes, atypical lymphocytes and blasts. Sysmex Adaptive FLagging Algorithm based on Shape-recognition (SAFLAS) is based on linear discrimination of cell clusters in the WDF scattergram using shape and positioning of different mononuclear cell populations.

Technology:

Fluorescent Flow Cytometry, SAFLAS

Parameters reported:

NEUT%, NEUT#, LYMPH%, LYMPH#, MONO%, MONO#, EO%, EO#, IG%, IG#

Reagents:

Lysercell® WDF and Fluorocell® WDF

This graphic demonstrates how different cell populations, particularly monos and lymphs, can be separated using population density readings and side scatter vs. fluorescent analysis.

Targeting lymphocytes and monocytes, SAFLAS recognizes not only the numbers of cells but also the shape of each cluster’s position, angle, size, length, etc.

SFL = Side Fluorescent LightSSC = Side Scattered Light

Page 5: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

Technology:

Fluorescent Flow Cytometry with platelet-specific dyes

Parameters reported:

Platelet-F Count, Immature Platelet Fraction (IPF)

Reagents:

CELLPACK® DFL, Fluorocell® PLT

The XN-Series uses impedance as the primary method for most platelet counts. When platelet accuracy cannot be guaranteed via impedance, the count is flagged. The XN automatically reflexes to a new fluorescent channel and increases the counting time six-fold.

In the new Platelet-F channel, platelets are identified and counted using a platelet-specific, fluorescent dye, Oxazine, which stains the rough-surface endoplasmic reticulum and mitochondria. This staining has excellent correlation with CD41/CD61 stained platelets and minimizes RBC fragment, microcytic RBC and WBC fragment interference.

The Immature Platelet Fraction (IPF)

Just as we can analyze reticulocytes and other immature cells, the XN-Series brings similar capabilities to platelet analysis. The IPF is a direct cellular measurement of thrombopoiesis and can be used with other available clinical information to help determine the pathophysiological mechanism of thrombocytopenia.

FSC = Forward Scattered LightSFL = Side Fluorescent Light

XN-9000-301 with Lavender Top Management® and Intelligent Automation System including post-analytical tube sorting, archiving and automation of HbA1c testing

The New Platelet-F Channel for Low Platelet Counts

Page 6: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

The time-proven parameters reported by the Reticulocyte Channel give clinicians a complete cellular assessment of erythropoiesis. These measurements are performed automatically on the XN-Series with no offline sample preparation.

Red cells circulating in the peripheral blood are classified and differentiated based on size and maturation state. This provides both quantitative and qualitative information and is a direct cellular measurement for erythropoiesis. It has been found to be useful for providing improved anemia screening and monitoring of iron therapy when used in conjunction with other available clinical information.

LFR = Low Fluorescing ReticsMFR = Medium Fluorescing ReticsHFR = High Fluorescing ReticsIRF = Immature Retic Factor = MFR + HFR

Technology:

Forward Scatter and Side Fluorescence

Parameters reported:

RET#, RET%, IRF (Immature Reticulocyte Fraction) and RET-He (Reticulocyte Hemoglobin)

Reagents:

CELLPACK® DFL, Fluorocell® RET

The RET Channel

Cartridge ReagentsThe fluorescent dye packs are “printer style” cartridges that allow fast, easy replacement. The RFID (Radio Frequency ID) technology optimizes correct placement, inventory control, and recording and reporting.

FSC = Forward Scattered LightSFL = Side Fluorescent Light

Page 7: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

Two-Part Differential Standard with Every Body Fluid Analysis

It’s never been easier or faster to analyze body fluids than on the XN-Series. We’ve even eliminated most offline sample preparation and the need for additional reagents. Your lab can produce highly accurate results with less manual effort.

Cerebrospinal fluid (CSF)

Pleural fluid

Peritoneal fluid

Synovial fluid

Body Fluid Analysis

Technology:

Fluorescent Flow Cytometry

Parameters reported:

WBC-BF, TC-BF, RBC-BF*, PMN%, PMN#, MN%, MN#

Reagents:

Lysercell® WDF and Fluorocell® WDF*Impedance measurement using CELLPACK DCL

SFL = Side Fluorescent LightSSC = Side Scattered Light

Page 8: Advanced Clinical Parameters and Technology · Advanced Clinical Parameters and Technology XN-Series™ Automated Hematology Analyzers Count on Sysmex to do more than just talk about

©2014 Sysmex America, Inc. MKT-10-1176 V02/18/14-D

Sysmex Corporation1-5-1-Wakinohama-KaigandoriChuo-ku, Kobe 651-0073, JapanTel. +81 (78) 265-0521www.sysmex.co.jp

Sysmex America, Inc.577 Aptakisic RoadLincolnshire, IL 60069, U.S.A.Tel. +1 (800) 379-7639www.sysmex.com/us

Sysmex Canada, Inc.5045 Orbitor DriveBuilding 9, Suite 401Mississauga, ON, L4W 4Y4, CanadaTel. +1 (905) 366-7900www.sysmex.ca

Sysmex Latin America and the Caribbean Rua Joaquim Nabuco 615 - Bairro Cidade JardimSão José dos PinhaisParaná – Brasil – CEP 83040-210Tel. +55 (41) 2104-1314www.sysmex.com.br