Advanced Seminar
Class Objectives
• Provide a understanding of spa functionality
• Key troubleshooting tips
• Hands-on electrical exercising & simulating
• Communicating with D1
• RTV, warranty
Agenda 9:00 Spa Controls Theory : presentation of various
controls of a D1 spa – electrical connections, differential breaker, networks.
Upper control panels and PC boards : evolution in time - D1, D11, D12, D13, D14, D15, D17, D18-CE systems
Practice : PC board hook-up under tension, use of a voltmeter, ammeter, ohmmeter
Peripheral elements : sensors, test and ohms resistance
12:00 Lunch
Agenda
• 13:00 Massage sequencer, power-up, electrical measures, solenoid valves and their functionality
• 14:00 Troubleshooting tips, common issues, searching for defaults, practice
• 15:00 Spa water treatment – specifics, ozonation, UltraPure system, water chemistry
• 15:30 Hands-on Skirt light LFX• 16:00 Spa shell repair : UltraLife kit ingredients :
chips, MEK, Plastic Welder Warranty conditions• Questions, Evaluation Test
Spa Power Requirements & Measurements
Single phase type connection
• Neutral & Line 1 = 230 VAC• Wire Requirements for 1 x 32 A : 3 x 6 mm²• Wire Requirements for 1 x 16 A : 3 x 2.5 mm²• Electrical cable with 3 conductors : Use industrial type cable : U-1000 R2V Ground (green/yellow), Neutral (blue), Phase
(black, brown or red)
Line 1 & Neutral = 230 V AC
Spa Power Requirements & Measurements
Two-phase type connection
• Neutral & Line 1 = 230 V AC• Neutral & Line 2 = 230 V AC• Wire Requirements for 2 x 16 A : 4 x 2.5 mm²• Electrical cable with 4 conductors :
Use industrial type cable : U-1000 R2V
Ground (green/yellow), Neutral (blue),
Phase 1 & 2 (black, brown or red)
Line 2 & Neutral = 230 V AC
Spa Power Requirements & Measurements
Three-phase type connection• Neutral & Line 1 = 230 V AC• Neutral & Line 2 = 230 V AC• Neutral & Line 3 = 230 V AC• Wire Requirements for 3 x 16 A : 5 x 2.5 mm²• Electrical cable with 5 conductors :
Use industrial type cable : U-1000 R2V
Ground (green/yellow), Neutral (blue),
Phase 1, 2 & 3 (black, brown or red)
Transformer Voltage InInput = 230 V AC
Output = 12 V ACSupplies digital power, 15 V DC & light
Output 24 V ACUsed to energize coils of Relays
Peripheral Power Requirements
• 230 V AC = Jet pumps & Heater
• 230 V AC = Circulation pump, Ozone Generator, Fan, Sequencer
• 12 V AC = Light or LFX
• 15 V DC = iWatch/Skirt Light
• 24 V AC = Solenoid valve
Spa Controls
• Micro-Controller = brains of spa
• Upper control is a means of communicating with the Micro-Controller to : - command
- acknowledge - activate
• Battery 5.5 VDC to keep data in memory
Spa Controls
Compatibility between upper control panels and PC boards
• The old Gecko system MSPA-1 required a D1-CE PC board, ref. 01710-125E, with its specific sensors for temperature & hi-limitThis PC-Board is not longer manufactured, at disposal while stocks last. It will be replaced with a D11 kit.
• Associated upper control panel : • * TSC-24, intelligent base from mid 1999
to 2001, ref. 01560-310
* TSC-25, mid-range from 1999 and up
ref. 01560-320, used on Arena
Upper control panels still in use
• TSC-24-D13 ref. 01580-0001 with Gecko MSPA-MP system & scrolling messages used until end of 2006 with following PC boards :
* D11-CE ref. 01710-1008E for Reflection Line
* D12-CE ref. 01710-1010E for Bay Collection• TSC-42 ref. 01560-1005 for massage
sequencer• TSC-17 ref. 01560-325 for secondary control
M-Drive Upper Control
Present M’Drive used for Bays, Reflection Line & AFS
• UPPER CONT-IN.K961.D15-MP, last revision, new ref. 01710-1026
• associated PC board for Bays D15-CE, ref. 01710-1018E
• associated hi-limit sensor ribbon type, plug able ref. 01560-1016
• PC board for LFX spas D18-CE, ref. 01710-1020E
• PC board for non-LFX spas D17-CE, ref. 01710-1019E
Relays & Snubbers
MCMicro -
controller
Pump230 VAC Relay
R C
MeasurementsNO
Proper Measurement
Feedback to the Microcontroller
• Temperature Probe – Tells Microcontroller to activate/deactivate the heater (also OH)
• High Limit Probe – Informs microcontroller if heater is getting too hot. Red LED
• Flow/Pressure Switch – Tells microcontroller if water is flowing through heater in a satisfactory quantity
Micro
Controller
Relays for pumps, heater,
ozone generator and fan
Relays for pumps,
Heater, ozone generator
& fan
Microcontroller Communication Diagram
Upper
Control
Panel
Upper
Control
Panel
Upper
control
panel
Temp. Sensor
Hi-limit sensor
Flow switch
Upper Control Errors/Conditions
Hard Failures• Flow open (FLO) / Flow closed (FLC)• High Limit (HL) – Temperature limit 48°C• Overheat (OH) of water 44°C
Conditions• Communication Error – Lock-Up : - - - - F• Summer Mode – Lower set temp. to 15°C• Ice Condition at 20°C in the cabinet• Fan starts at 65°C -> 60°C or with pump (1 hour)
Termistor on PC board (R9)Battery 5.5 VDC
FLO / FLC
High Limit red LED on
TSC-24 Upper Control Programming
• High level programming menu Holding the Program key for 5 seconds
• Low Level Service Menu Holding both Program and Icon keys for 10 sec
• Upper Control Test Mode Hold Jets 1 key while powering up spa
• Demonstration Mode (Reminders) Jets 1 key must be held for 10 seconds
• Manual System Reset
Press : Icon, Enter and then Program keys
• Invert the LCD
Press : Program key 3 times
• Programming Lock
Press : Icon, Icon and then Program keys
• Control Panel Lock
Press : Icon, Icon and Enter keys
• Unlock Press : Enter, Enter and Icon
• Stand-By Mode
Press : Icon button for 5 seconds
Jumpers & Settings(D15-CE) 2008 AFS with Bay pack
Jumpers & Settings(D15-CE) 2008 AFS/Bay
For AFS – Pumps 2 and 3, single speed• Jumper 4 – Right• Jumper 5 – Left
For AFS – No waterfall• Jumper 6 – Right• Jumper 7 – Left (Dynamic Lighting)• Jumper 8 – Left (Heater management enabled)• Starting S/N with software 3.00 Bays is 156956
Jumpers & SettingsD18-CE LFX Reflections &
D13-CE exclusive to ’05 Californian
1 & 2 Breaker rating3 UltraPure4 Circulation Pump5 Dynamic Lighting6 Pump # 2 installed7 Pumps 1 & 2 single speed8 Waterfall
Californian / Dupree• SofTouch Luminosity - custom handle
- backlit Pentair air valves
- new software : allows 3 unique lighting levels . Brilliant mode : all lights on
. Candle mode : bar top & fountain
. Fountain mode : fountain only
To change, turn light off and wait for text “light off” message to disappear
To lock color, press light button twice rapidly.
• New Liquid FX fountain - 88 watt Laing pump
- interchangeable heads for aquatic visual & audio experience
Dupree Bay / Californian• Same PC board as
bay series.
• Jumper 4 needs to change for 2 pump system.
• New PC board (D13) to accommodate fountain
Poly Planar Audio System
Possible conditions
• Stereo Screen does not light up
• Screen lights up but no sound
• One or more speakers are not playing
• How to program the Dolphin II remote
Check purple J+J plug behind the control and
make sure it’s connected; follow it to the main board and check power between
P40 and P55
Do you get 230 VAC ?
NO
Stereo screen does not light up after pressing power.
Get a good source of power,
try :
N – P40
L1 – P90
If you still don’t have 230 VAC,
check the incoming power to the spa, you are not getting the required
voltage.
Behind the stereo, check power on red and black
wires. Do you get 12 VDC ?
YES
Open the power supply and check
the fuse; if bad replace it. Do you get 12 VDC now ?
NO
NOYES
Check both inline fuses on the stereo
(red and yellow wires); if bad
replace them. Does the screen light up
now ?
NO
YES
Does it play now ? YES Problem solved
NO
Refer to screen lights up,
but no sound.
Replace Stereo head
unit.
Replace power supplyIf the stereo is equipped
with an IMR-200 Module, with power off, remove it and then reset the power, does the screen light up
now ?
NO YES
Stereo screen lights up but no sound comes out.
Scan for a good radio station or put a CD that you know is good.
Put the volume at level 15.
Balance and fade at center or zero and check 12 pin harness for loose connections. Does the stereo play
now ?
If the stereo is equipped with an IMR-200 Module, with power off, remove it and then reset the power.
Does the stereo play now?NO
NO
Replace Stereo head
unit.
YES
Replace IMR-200 Module, reset power.
Does it play now ?
YES
If all speakers play good, problem solved; if not refer to : one or more speakers are not
playing.
YES
NO
Replace IMR-200 and
Stereo head unit at the same time.
One or more speakers are not playing
A pair of
speakers
One speaker (right or left
channel)
Remove, and disconnect the bad speaker and test a new one. Does it play now?
To find out if the speaker is good, check ohms on green and yellow wire, you should hear a beep or read 4 to 6 ohms. Subwoofer 3+ - .
YES
NO
Check for cut speaker wires or pulled pins on the
connections, repair any problems. Does
it play now?
YES
Solved
Replace the
speaker.
NO
Send a new speaker wire from your new speaker to the 12 pin harness and test by connecting
it on the pair of gray or white wires,depending where it is coming from. Does it play
now?
YES
NO Your are on your own!!
I mean call us for help
Tuck in the new wire thru the skirt
If the stereo is equipped with an IMR-200 Module, with power off remove it
and then reset the power, does that channel plays
now ?
YES
NO
Remove both speakers and
test a new one. Does it
play ?
YESReplace
both speakers.
Replace stereo head unit. Do the speakers play now ?
Test a new stereo head unit, Does it play now ? YES
Replace IMR-200 Module
NO
NO
Test a new 12 pin harness. Does it
play now ?YES
Replace 12 pin
harness
NO
How to program the Dolphin II remote
SPA Poly Planar stereo
Aiming at the top side control or I-watch, press on the remote
SPA button, then at a function, (jets, light, etc) does it activate ?
YES
YES
YESAlready
programmed
Pointing at the Stereo, press on RCVR, then power; does it turn
on ? (try also CD button)
NO
Press SPA button (Led will blink once)
Press and hold Setup (Led will blink twice)
Enter 1842 on the key pad.
Aim at the top side and test again.
Does it activate ?
Solved
NO
Try again, replace batteries if it does not solve the problem. You might have an older Dolphin remote or a
loose connection on the TSC harness at P8.
@home spas are not remote capable.
NO
Press RCVR button (Led will blink once)
Press and hold Setup (Led will blink twice)
Enter 1914 on the key pad.
Aim at the top side and test again.
Does it activate ?
Also try 1843.
0101 for In-tune head unit.
YES
NO
Try again, replace batteries if it does not solve the problem you might have an older Dolphin remote.
Make sure this spa is equipped with an IMR-200 to be able to use the speakers as an infra-
red receiver.
Magnetic switches – Bays only
• Magnetic switch board having 2 green LED’s, which must be lit
• SARB and LOTB having 4 magnetic buttons to activate Lighting (top button) and Pump 3 (lower button)
• Dupree Bay having 4 buttons to activate Lighting and both Pumps 1 & 2
• Amoré Bay has 6 buttons : Light or Fountain (top), Pump 3 or Pumps 1 & 2
Massage Sequencer
• Power input 230V• Fuse (3.15A)• Transformer 230V / 24 V• PC board DJS-2-D12
ref. 01710-1200• Jumper settings for 2
sequencers• Solenoids and valves• Light & Jet buttons
interface with PC board• Sequence buttons
Common Issues• Circulation Pump Cleaning• Sta-Rite Pump Seals & Volutes • Solenoids & Valves• Flow & Pressure Switches• Check Valves – pop check / ozone check• Heaters- Amp check – Insulation check• Differential – Current to trip = 30 mA• Jets• LFX and skirt lighting
Technical news• The new E 10 circulation pump• The new plumbing on the AFS• The most important problem last year:
M-Drive: this problem is solved with the revision D 15.PC-Board D15 on Bays: 152300 to 156942, the orginal PC-board contains a software error, the problem is then a OH Message, with or without a effective overheating.
Water Chemistry
• Ozone Generator
• Vision cartridge
• Chemicals
• Chemistry Damage
Working with D1• Technical Service Dept.
- Have S/N
- Pictures
• Warranty Dept.
- Parts Returns
- How / When to return parts