11
Aerators Aerators 091911 21

Aerators - Flow-Rite of the plumbing required by other systems. ... Aerators 30 Flow-Rite Controls 960 74th St., Byron Center, MI 49315 Spray head, Straight

  • Upload
    lyanh

  • View
    219

  • Download
    1

Embed Size (px)

Citation preview

Aera

tors

Aerators

09191121

Aer

ato

rs

Aerators

Flow-Rite Controls 960 74th St., Byron Center, MI 49315 www.flow-rite.com22

The PowerStream Aerator features a venturi air intake at the top of the discharge head to maximize the oxygen entering the livewell water. The longer mixing tube directs this mixture directly to the depths of the livewell and is then discharged horizontally well below the water line through the discharge nozzle at the bottom of the tube. The discharge nozzle is adjustable and can be rotated 360º. Since the thru-hull fitting and venturi intake are mounted above the livewell water line, it can be used with either a transom mounted fill pump or a livewell mounted recirculation pump without worry of water being siphoned out when the pump is off. It includes a special elbow thru-hull fitting.

TOP VIEW

Venturi Air-IntakeAllows air to be brought in and mixed with water

Locking NutLeave aproximately 3/16” of threads on thru-hull exposed for the locking nut which is designed to allow the mixing tube assembly to swivel if bumped while prevent-ing detachment

Discharge PortCan be rotated in any direction to circulate the water in the livewell

Mixing TubeWater and air are mixed together before exiting the discharge port

360º

Typically mounted near a corner of the livewell,

some of the possible mounting locations are shown here. Rotate the

discharge to promote circulation.

PowerStream Aerator

Aera

tors

Aerators

09191123

4"

(see

cha

rt fo

r ava

ilabl

e le

ngth

s)

7/8"

1/2"

2"

2"

Water

Air

Qwik-LokPart #

BarbedPart #Length

PowerStream Aerator w/Thru-hull, Standard MH-PSA-209 MH-PSA-1098-7/8”PowerStream Aerator w/Thru-hull, Long MH-PSA-215 MH-PSA-11514-7/8”PowerStream Aerator w/Thru-hull, Extra Long MH-PSA-222 MH-PSA-12221-3/4”

Aer

ato

rs

Aerators

Flow-Rite Controls 960 74th St., Byron Center, MI 49315 www.flow-rite.com24

The PowerStream Nozzle features a venturi air intake in the top of the nozzle that draws additional oxygen into the water as it enters the livewell. Unlike typical overhead spray heads, oxygen rich water immediately penetrates the deepest livewells with ease and can be rotated left or right for a circular current of the livewell water. A special elbow thru-hull fitting is included.

Venturi Air-IntakeAllows air to be brought in and mixed with water

Locking NutLeave aproximately 3/16” of threads on thru-hull exposed for locking nut

Discharge NozzleCan be rotated to provide circula-tion in the livewell

TOP VIEW

Nozzle may be rotated left or right to promote livewell water circulation

• Typically mounted near a corner of the livewell, some of the possible mounting locations are shown here. Rotate the discharge to promote circulation.

PowerStream Nozzle

Aera

tors

Aerators

09191125

4"

2"

1/2"

7/8"

2"

WaterAir

Qwik-LokPart #

BarbedPart #

PowerStream Nozzle w/Thru-hull MH-PSN-200 MH-PSN-100

Aer

ato

rs

Aerators

Flow-Rite Controls 960 74th St., Byron Center, MI 49315 www.flow-rite.com26

A pump-out feature provides a convenient means of filling a tournament livewell weigh-in bag and also enables a livewell to be pumped out while the boat is still in the water or when moored at a dock overnight.

The Flow-Rite Pump-Out Aerator is the easiest, most efficient, and least expensive means of adding a pump-out system to any livewell system. It eliminates the need for additional diverting valves, cables, actuators, electrical connections and most of the plumbing required by other systems. Simply install the Pump-Out Aerator in place of the standard spray head used with any recirculation pump or with any of our V3 or V4 control valves that include a “RECIRC” mode. It has two hose connections, one intake from the pump and one outlet for the discharge hose that will connect to the new discharge thru-hull fitting.

The two position head is pushed in to bring water into the livewell where it is recirculated and aerated by the air intake and venturi built into the head. Pull the head to the out or “pump-out” position to divert the water from the livewell to the discharge thru-hull. The head can also be rotated left or right to promote a desirable circular current within the livewell. The venturi will ensure that the maximum amount of oxygen allowed by ambient conditions will be provided to all levels and areas of the livewell.

Aerator HeadSimply pull to pump-out and push to aerate

Pump-out PortConnects to pump-out thru-hull

Intake PortConnects to recirc pump

Venturi Air-IntakeAllows air to be brought in and mixed with water

Locking NutLeave aproximately 3/16” of threads on thru-hull exposed for locking nut

Discharge NozzleCan be rotated to provide circulation in the livewell

Pump-Out Aerator

Aera

tors

Aerators

09191127

Recirc Pump-Out

Recirc Pump-Out

Pump-Out Aerator with livewell mounted recirculation pump

Pump-Out Aerator with a V3 or V4 valve system in RECIRC mode

Note: Place control valve in the “RECIRC” position when using pump-out

5 3/4"

2 7/

8"

1"

1/2"

2 5/8"

2"

A special thru-hull fitting is available for use with the Pump-out Aerator. MA-020-B

(barbed) and MA-020-QLB (Qwik-Lok) Qwik-LokPart #

BarbedPart #

Pump-Out Aerator MA-024-QLR MA-024-RPump-Out Aerator Retail Pack wThru-hull, decal, & instructions N/A MP-1000Discharge Straight Thru-hull, black w/Decal MA-020-QLB MA-020-BDischarge Elbow Thru-hull, black (no decal) MA-027-QLB MA-027-B

Aer

ato

rs

Aerators

Flow-Rite Controls 960 74th St., Byron Center, MI 49315 www.flow-rite.com28

The Power-Jet aerator is designed to be mounted well below the surface of the livewell for direct introduction of fresh oxygenated water. It can be used with systems 2, 3, or 4, or a livewell mounted aerator pump only. (It is not for use with a transom mounted pump.) Includes a special air intake fitting with gasket and nut.

TOP VIEW

Air Intake TubingEasily routed and may be cut to lenth to suit speci�c needs.

Remote Venturi IntakeVenturi air intake has many mounting options and can be mounted anywhere above water level. Shown here with optional domed decal.

Discharge NozzleShould be mounted near a corner to promote livewell water circulation.

Typically mounted near a corner of the livewell to promote circulation,

some of the possible mounting locations are shown here.

Power-Jet Aerator

Aera

tors

Aerators

09191129

Qwik-LokPart #

BarbedPart #

PJA w/Air Intake Assy, (No decal, no air tubing) MH-PJA-200 MH-PJA-100PJA w/Air Intake Assy & 20" Air tubing, (no decal) MH-PJA-220 MH-PJA-120PJA w/Air Intake Assy w/60" Air tubing & Decal w/ White lettering MA-1043 MA-1044PJA w/Air Intake Assy w/60" Air tubing & Decal w/ Gold lettering MA-1045 MA-1046Air Tubing, 3/16" I.D., Sold by foot MD-055Domed Decal, Single White lettering LBL-PJ1-WDomed Decal, Single Gold lettering LBL-PJ1-GDomed Decal, Double White lettering LBL-PJ2-WDomed Decal, Double Gold lettering LBL-PJ2-G

3"

2 7/

8"

1 3/4"1/2"

2"

1 3/8"

5/8

"

3/4"

1/4"

FLO

W-RITE

Pow

er-Jet Air In

take

Pow

er-Jet Air In

take

FLO

W-RITE

DCL-PJ2-G

DCL-PJ1-G

DCL-PJ2-W

DCL-PJ1-W

Air Intake Mounting OptionsMounting air intake without decalDrill a 3/8" hole in a location well above the highest water line of the livewell in an area that allows the routing of the air intake tubing. Insert air intake with rubber gasket. Use a 3/16" allen wrench in air intake head while tightening nut on back side of tank wall. Push air hose onto air intake.

Mounting air intake with decalPick a location well above the highest water line of the livewell in an area that allows the routing of the air intake tubing. This is usually an area along the vertical rise of the gunnel. Drill a 3/8" hole, deburr and clean surrounding area with alcohol. Mount the air intake fitting to a 3/16" allen wrench. Carefully remove decal from protective backing and insert intake fitting through center hole.

Mounting air intake when there is no access to back of mounting surfacePick a location well above the highest water line of the livewell in an area that allows the routing of the air intake tubing. This is usually an area along the vertical rise of the gunnel. Drill a 3/4" hole, deburr and clean surrounding area with alcohol. Route tubing from aerator leaving a few inches of excess tubing out hole. Mount the air intake fitting to a 3/16" allen wrench. Carefully remove decal from protective backing and insert intake fitting through center hole. Install mounting nut. Install air intake tubing to air intake fitting. Orient the text properly and push assembly into 3/4" mounting hole. When decal is firmly bonded to surface, remove allen wrench.

Aer

ato

rs

Aerators

Flow-Rite Controls 960 74th St., Byron Center, MI 49315 www.flow-rite.com30

Spray head, Straight

Spray head, Elbow

• Spray head may be rotated to promote livewell water circulation

• Spray head may be rotated to promote livewell water circulation

3 7/8"

5/8"1 3/4"

2"

1/2"

3 1/4"

5/8"1"

2 7/

8"

2"

Qwik-LokPart #

BarbedPart #

Sprayhead, Straight MA-071-QLW MA-071-W

Qwik-LokPart #

BarbedPart #

Sprayhead, Elbow MA-077-QLW MA-077-W

Spray Head Aerator

Aera

tors

Aerators

09191131

Spray head with Shut-off

• Fully adjustable from off to fully open

• Ideal for use with single fill pump routed to two or more bait or livewells

• Not for use with V2 or V3 automatic system

4 1/4"

2 3/

8" 1 5

/8"

CLOSE - OPEN

Qwik-LokPart #

BarbedPart #

Sprayhead with Shut-off MA-051-QLW MA-051-W