1
HVAC ENERGY USE INTENSITY kBTU / ft 2 / year 50 40 30 20 10 0 Pre- Conversion Post- Conversion 64% Lower Philadelphia, PA HVAC FACTS Fuel Source HVAC System CFM Tons Heat: Electric with Geothermal Cool: Electricity VRF Electric with Geothermal Components; VS1000 RT units with ducting into 25 individual units TBD TBD FOURTH FLOOR MECHANICAL PLAN Unit 43 Unit 44 Making Buildings Healthy Efficient Smarter 2828 SW Corbett Ave, Suite 119 Portland, OR 97201 1-888-VENTIL8 (888-836-8458) ventacity.com AFFORDABLE, NET ZERO ENERGY URBAN LIVING CASE STUDY MULTI-FAMILY RESIDENTIAL URBAN FLATS INNOVATE WITH ENERGY & DESIGN The co-founder of this architecture/development/construction firm describes this project as their “most-challenging- to-date.” In addition to meeting the Passive House standard, this 25-unit multifamily building will aim for Net Zero Energy performance, with the assistance of a geothermal ground loop for heating/cooling and hot water; and an 83kW solar array. Passive House is “about 80% better than code,” and this building should have an EUI of about 15 kBtu / ft 2 / year. Many other design-build firms might say the Passive House standard is out of reach for new low-income housing, but this firm has made it the norm for their projects. They estimate in a recent article that this can be achieved with an incremental increase in construction costs of as little as 2%, while ensuring monthly affordability and comfort for generations to come. An EUI of 15 is only 35% of expected EUI in New Construction “Reference Buildings” for this climate zone. Ventacity Systems is excited to be considered for this project, not only for energy conservation, but also because of the firm's inspiring dedication to historic Philadelphia neighborhoods. Building Construction Year Occupancy Type Number of Stories Conditioned Area Ownership New Construction 25 Unit Multi-Family 4 Approx. 13,000 ft 2 Private INSTALLATION FACTS

AFFORDABLE, NET ZERO ENERGY URBAN LIVING · HVAC ENERGY USE INTENSITY kBTU / ft 2 / year 50 40 30 20 10 0 Pre-Conversion Post-Conversion 64% Lower Philadelphia, PA HVAC FACTS Fuel

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: AFFORDABLE, NET ZERO ENERGY URBAN LIVING · HVAC ENERGY USE INTENSITY kBTU / ft 2 / year 50 40 30 20 10 0 Pre-Conversion Post-Conversion 64% Lower Philadelphia, PA HVAC FACTS Fuel

HVAC ENERGY USE INTENSITY

kBTU

/ ft2

/ yea

r

50

40

30

20

10

0Pre-

ConversionPost-

Conversion

64% Lower

Philadelphia, PA

HVAC FACTS

Fuel Source

HVAC System

CFM

Tons

Heat: Electric with GeothermalCool: Electricity

VRF Electric with Geothermal Components; VS1000 RT units with ducting into 25 individual units

TBD

TBD

FOURTH FLOOR

MECHANICAL PLAN

Unit 43

Unit 44

Making Buildings Healthy – Efficient – Smarter

2828 SW Corbett Ave, Suite 119

Portland, OR 97201

1-888-VENTIL8 (888-836-8458)

ventacity.com

AFFORDABLE, NET ZERO ENERGY URBAN LIVING

CASE STUDY MULTI-FAM

ILY RESIDENTIAL

URBAN FLATS INNOVATE WITH ENERGY & DESIGNThe co-founder of this architecture/development/construction firm describes this project as

their “most-challenging- to-date.” In addition to meeting the Passive House standard, this

25-unit multifamily building will aim for Net Zero Energy performance, with the assistance of a

geothermal ground loop for heating/cooling and hot water; and an 83kW solar array. Passive

House is “about 80% better than code,” and this building should have an EUI of about 15 kBtu

/ ft2 / year. Many other design-build firms might say the Passive House standard is out of reach

for new low-income housing, but this firm has made it the norm for their projects. They

estimate in a recent article that this can be achieved with an incremental increase in

construction costs of as little as 2%, while ensuring monthly affordability and comfort for

generations to come. An EUI of 15 is only 35% of expected EUI in New Construction “Reference

Buildings” for this climate zone. Ventacity Systems is excited to be considered for this project,

not only for energy conservation, but also because of the firm's inspiring dedication to historic

Philadelphia neighborhoods.

BuildingConstruction Year

Occupancy Type

Number of Stories

Conditioned Area

Ownership

New Construction

25 Unit Multi-Family

4

Approx. 13,000 ft2

Private

INSTALLATION FACTS