AI110AIswitch Series 110 Chassis
Installation Guide
Part Number QR-110 Rev 5
© 2007 by Kentrox, Inc. All rights reserved.Copyright © 2007 by Kentrox, Inc. All Rights Reserved. The material discussed in this publication is the proprietary property of Kentrox, Inc. Kentrox retains all rights to reproduction and distribution of this publication.
Kentrox is a registered trademark of Kentrox, Inc. Applied Innovation, Applied Innovation Inc., the AI logo, and other names are the intellectual property of Kentrox. All other product names are trademarks or registered trademarks of their respective owners.
Information published here is current as of this document’s date of publication, but is subject to change without notice. You may verify product information by contacting our headquarters in Oregon. Kentrox is an Equal Opportunity/Affirmative Action employer.
Kentrox, Inc.5800 Innovation Dr.
Dublin, Ohio USA 43016-3271Toll Free: (800) 247-9482
International: +1 (614) 798-2000Fax: +1 (614) 798-1770
20010 NW Tanasbourne Dr.Hillsboro, Oregon USA 97124-7104
Toll Free: (800) 733-5511Direct: (503) 643-1681
AI110AIswitch Series 110 Chassis
Installation Guide
This installation guide explains how to install an AI110 AIswitch series 110 chassis.
Guide to this document
Product Components
Cautions and Warnings
Customer Assistance
Required Items
Installation
Calculating Power Consumption and Heat Dissipation
Technical Specifications
1
Product Components
Product Components
Front Panel Components
Figure 1 Front Panel Components
ChassisGround
ESDGround
Reset
-48 VDC Power Connections
-48 VDC Alarm Connections
Fault—Illuminates when there is a fault.
DC OK—Illuminates when the power is on.
2
Cautions and Warnings
Cautions and Warnings
Grounding and Electrical Safety
CAUTION: AI equipment and its peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised:
You must remove and install cards in a static-free environment. Wear an antistatic wrist strap that is plugged into the AI equipment so you are grounded at the same point as the equipment.
Do not remove cards from their antistatic plastic bags until you are ready to install them into the chassis.
Immediately after you remove a card from the chassis, you must insert it into its antistatic bag.
When the cards are not in use, keep them in their antistatic plastic bags.
Do not ship or store cards near strong electrostatic, electromagnetic, or radioactive fields.
Installation
CAUTION: For AI equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground.
Environment
CAUTION: In the event that AI110 has been subjected to adverse environmental conditions, a service inspection of AI110 should be made to ensure safe operation.
Lithium Batteries
CAUTION: Risk of explosion if battery is replaced by an incorrect type. Dispose of used batteries according to the instructions.
CAUTION: Il y a risque d'explosion si la batterie est remplacée par une batterie de type incorrect. Mettre au rebut les batteries usagées conformément aux instructions.
3
Cautions and Warnings
FCCThe Federal Communications Commission has set limits for emitted radio interference, and AI110 is constructed with this electromagnetic interference (EMI) limitation in mind. AI110 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15 Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference.
Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame.
Specifications are subject to change without notice.
4
Customer Assistance
Customer AssistanceKentrox offers technical support 24 hours a day, seven days a week.
Before you contact Kentrox for assistance, please have the following information available:
The type of hardware and software you are using
The error number and exact wording of any messages that appeared on your screen
What happened and what you were doing when the problem occurred
How you tried to solve the problem
Web Site SupportSupport is available 24 hours a day using our Web site at:
http://www.kentrox.com
Email SupportEmail support is available 24 hours a day. When you use email support, please be sure to include the details of your problem within the email.
To contact Technical Support, send email to:
Phone SupportPhone support is available. When you call Kentrox for support, please be sure you are at your computer and have the details of your problem available.
To contact Technical Support, call (866) 480-3571.
Kentrox Product DocumentationTo order documentation, please contact your sales representative at (800) 247-9482 or +1 (614) 798-2000.
You can also access and view the most current versions of Kentrox product documentation on our Web site at:
http://www.kentrox.com
5
Required Items
Required Items
Tools#2 Phillips screwdriver
3/64 in. (2.5 mm) slotted screwdriver
Crimping tool 1/4 in. (6.3 mm) capacity
Wire cutter
Wire stripper
PC with terminal emulation software such as Procomm (optional, used for configuration)
MaterialsWire for input power connections (14 AWG, copper conductor)
Wire for optional external alarm devices (28 to 16 AWG)
Wire for ground connection (10 AWG, copper conductor)
Ground lugs for rack or other earth ground
6
Installation
Installation
Step 1: Attach Mounting FlangesAttach the mounting flanges to fit a 19-inch or 23-inch rack. You can also attach the flanges in three locations providing multiple alignment options to the rack. Figure 2 displays a 19-inch configuration.
Figure 2 Mounting Flanges Attached for 19-inch Configuration
Multiple alignment options
7
Installation
Step 2: Attach AI110 to RackInstall the mounting screws into the mounting holes and tighten firmly.
Note: No minimum clearance required above or below the chassis.
Figure 3 Attach AI110 to Rack
Figure 4 AI110 Installed in Rack
8
Installation
Step 3: Attach Chassis GroundConnect the AI110 chassis ground to a suitable ground such as the frame ground of the rack system or to a reliable earth ground.
CAUTION: The chassis ground must be connected to the same earthing electrode conductor as the DC supply system or to a bonding jumper (from an earthing terminal or bus) connected to the earthing electrode of the DC supply system.
The chassis must be located in the same immediate area (such as adjacent cabinets) as other equipment connected to the same DC power system and earthing electrode conductor. The DC system cannot be earthed elsewhere.
The DC power source must be located in the same premises as the chassis.
No switching or disconnecting devices can be between the earthed conductor of the DC source and the earthing electrode conductor.
Note: Apply an appropriate antioxidant to the bare conductors before crimping the connector and the connector mating surfaces.
Figure 5 Attach Chassis Ground
Ground ConnectionUser 10 AWG, copper conductor only.
9
Installation
Step 4: Connect Input PowerTurn off the power supply. Connect the input power feed to the power supply connector B using the A inputs. Be careful to observe polarity. If using a redundant input power feed, connect the other input power cable to connector B using the B inputs.
WARNING: Turn off both power feeds before connecting wires.
CAUTION: A readily accessible disconnect device (suitably approved and rated) must be incorporated in the field wiring.
The DC branch listed circuit breaker must be rated 15 A, maximum at 48 V, minimum.
Figure 6 Connect Input Power
To connect wires:
1. Turn off the power feed.
2. Strip the ends of the wire 5/16 in. (7mm).
3. Loosen the screws at the top of the connector.
4. Insert the wires into the connectors and tighten the screws.
Connector A Connector B
When connecting input power, make sure that you:
Connect to a reliably grounded 48 VDC safety extra-low voltage (SELV) source
Use 14 AWG copper conductors only
10
Installation
Step 5: (optional) Connect External Alarm DevicesConnect the external alarm signaling devices to the alarm relay contacts. The normally-opened or normally-closed outputs can be used to trigger external alarm devices.
Note: The relay output will be in the alarm condition until power is applied to the unit.
WARNING: Turn off the power feed before connecting wires.
Figure 7 Connect External Alarm Devices
To connect wires:
1. Turn off the power feed.
2. Strip the ends of the wire 5/16 in. (7mm).
3. Loosen the screws at the top of the connector.
4. Insert the wires into the connectors and tighten the screws.
These contacts operate if the power supply fails or input power is lost.
These contacts operate if the chassis overheats.
Contact rating:1 A at 50 VDC, maximum, resistive load.
Use appropriate wire size for application
11
Installation
Step 6: Install Line Card
CAUTION: Personnel handling cards must wear an antistatic wrist strap and follow electrostatic procedures.
To install the line card into the chassis:
1. Position the card so the components are face up.
2. Align the card with the card guides of the chassis.
3. Gently slide the card into the chassis.
4. Firmly press the faceplate of the card until the internal connectors engage.
5. Tighten the two thumbscrews to secure the card to the chassis.
Step 7: (optional) Configure IP Address on a Line CardConfiguring the IP address on a line card allows the card to be accessed remotely. For complete configuration information, refer to the user documentation for the specific card.
Connecting1. Set the terminal emulation software on the PC/terminal emulator for 9600 baud,
no parity, eight data bits, one stop bit, no flow control.
2. Using a terminal cable, connect the PC/terminal to the connection port for the product (see Table 1).
3. Press ENTER.
4. At the login prompt, enter ai. This is the default password.
5. At the password prompt, enter ai. This is the default password.
6. Continue with the directions for the specific card (see next page).
Table 1 Line Card Connection Ports
Line Card Connection Port
AI232AI296
Asynchronous port 1
AIfocusAIwan
CRAFT port
AIextendAIfirewallAIflex
CONSOLE port
12
Installation
AI232, AI296, or AIwan1. At the prompt, enter ip init.
2. Follow the on screen prompts to enter the IP address as well as a primary and backup router.
Note: You must reset the device before the changes take effect.
AIflex or AIfocusTo set the IP address:
At the system prompt, enter set-ip and the IP address.
Example: set-ip 123.45.255.90
To set the IP address and subnet mask:
At the system prompt, enter set-ip-conf, the IP address, and the subnet mask.
Example: set-ip-conf 123.45.255.90 255.255.0.0
Note: For changes to take effect, wait until the message Update Configuration Stored appears before rebooting the unit.
AIconnect, AIextend, or AIfirewallAt the prompt, enter config interface ethernet 0/, the port being configured, ip address, the IP address, and the subnet mask.
Example:
config interface ethernet 0/2 ip address 123.45.255.90 255.255.0.0
Note: The changes take effect as soon as you press ENTER.
13
Calculating Power Consumption and Heat Dissipation
Calculating Power Consumption and Heat DissipationThe following procedure describes how to calculate power consumption and heat dissipation for AI110.
CAUTION: Personnel handling cards must wear an antistatic wrist strap and follow electrostatic procedures.
1. Using Table 2, enter a 1 in the quantity field to the right of the name of the line card in the chassis. Multiply the Watts per Card by 1. Enter the amount in the Subtotals field to the right of the name of the line card in the chassis. Add the subtotal of the card and the subtotal of the chassis to obtain the total card consumption. (A value for the chassis has been added to the table.)
Table 2 Calculating Total Card Consumption
Card Watts per Card Quantity Subtotals
AI232 11.50 x __________ = ________ W
AI296 16.20 x __________ = ________ W
AIconnect (one PMC) 17.00 x __________ = ________ W
AIconnect (two PMCs) 24.50 x __________ = ________ W
AIextend 9.50 x __________ = ________ W
AIfirewall 9.50 x __________ = ________ W
AIfirewall (one PMC) 17.00 x __________ = ________ W
AIfirewall (two PMCs) 24.5 x __________ = ________ W
AIflex (all models) 27.00 x __________ = ________ W
AIfocus 3210 13.00 x __________ = ________ W
AIwan T1/E1 6.00 x __________ = ________ W
Chassis 6.90 x 1 = 6.90 W
Total Card Consumption = ________ W
14
Calculating Power Consumption and Heat Dissipation
2. Calculate the total power draw. Using Table 3, enter the Total Card Consumption obtained in Table 2. Multiply by the typical power supply loss factor at full load to obtain the total power draw in Watts.
3. Calculate the total chassis heat dissipation. In Table 4, enter the value obtained inTable 3. Multiply the Total Power Draw by the conversion factor 3.41 to obtain the Total Chassis Heat Dissipation in Btu/Hr.
Calculating Current DrawUse these steps to calculate the actual current that AI110 draws from the power source. Calculations are based on the Total Chassis Power. This total current is used by the site engineer to determine power plant capacity requirements.
Calculating Actual DC Current DrawTo find the actual DC current draw of AI110:
Table 3 Calculate Total Power Draw
Chassis Watts Power Supply Loss Factor Total Power Draw
Total Card Consumption(from Table 2) _______ W x 1.19 = ____________ W
Table 4 Calculating Total Chassis Heat Dissipation
Total Power Draw (from Table 3) = ____________ W
Conversion factor x 3.41
Total Chassis Heat Dissipation = ____________ Btu/Hr
Table 5 Calculating Actual DC Current Draw
Total Chassis Power (from Table 3) = ____________ W
Actual DC voltage at site / ____________ W
Divide Total Chassis Power by actual DC voltage at site = ____________ Actual Current
15
Technical Specifications
Technical Specifications
Specification Description
Card Slots 1 slot - supports a variety of line cards
Weight 7.2 lbs (4.05 kg), approximately
Size Height: 1.75 in. (4.45 cm)Width: 16.875 in. (42.86 cm)Depth: 10 in. (25.4 cm)
Mounting Mounts in a standard 19-in. or 23-in. rack (includes mounting flanges)
Clearance Requirements
Above the chassis: No clearance requiredBelow the chassis: No clearance required
Operating Environment (Ambient)
Temperature: 41° to 104° F (5° to 40° C)Relative humidity: 0% to 90% (non-condensing)
Power Includes dual A and B power inputs (individually fused)Voltage: -48 VDC, nominal (Range: -39 to -63 VDC)Current: 0.75 A at -48 VDC
Circuit Fuse (Power supply)
3 A, typical, external fused supply
Alarm Contacts Two sets of alarm contacts that operate in the event of a power supply failure or an over-temperature condition. Can be sued to activate external alarm devices.Rating: Dry contact, 1 A at 50 VDC, maximum, resistive load
Compliance and Certification
Underwriters Laboratories (UL): Conforms to all applicable sections of UL 60950Meets Telcordia Network Element Building Standards (NEBS) Level 3 functionality
Safety Equipment for use in a restricted access location only
16