Upload
others
View
8
Download
0
Embed Size (px)
Citation preview
PRODUCT CATALOGUE
SPLIT / WINDOWAIR CONDITIONERS LINE-UP
60HZ
High reliability products
1971Air conditioner exports
to Middle East.
Overseas air conditioning business starts.
Large wall mountedand multi
Big Multi
VRF tropical series
Commercial
19711985
2001
2013
for Large Building
2017
VRF tropic
2017
for Small Building
Top Leader Brandin Middle East
Fujitsu General started the sales of Window type air conditioner in 1960 and expands the overseas business from Middle East market earlier than competitors. We have developed the various powerful and long-life products from residential to commercial air conditioners to meet the severe Middle East market needs.
Residential
23
Reliability Testing
High reliability products High Quality Development & Production Facilities
Advanced Research Facility and Equipment
Performance TestingTransportation & Handling
Calorimeter testing Air flow testingSound testing
Vibration testing
Compressibility testing
Water shower testing Severe environmental testing
Testing Laboratory
Fujitsu General EMC Laboratory Limited
R & D Center Kawasaki, Japan
Fujitsu General has the advanced research facilities and equipment in Japan and provides exclusive products that meet the extreme weather condition test and high quality standards.We will continue to provide the products with high performance, durability, and energy saving.
60 m Height Difference Testing TowerObjective is to confirm oil circulation of compressor for reliability
ABOUT US
4
INDOOR UNIT LINEUP
18,000
24,000
25,000
30,000
36,000
40,000
50,000
60,000
Group
ASSA18FETAZASSA18UETAZ
ASSA24FETAZASSA24UETAZ
ASSA30FMTAZASSA30UMTAZ
ASSA36FETAZASSA36UETAZ
Duct Type
ARSA18FMTAZARSA18UMTAZ
AUSA40FRTAZAUSA40URTAZ
AUSA50FRTAAUSA50URTA
AUSA18FRTAZAUSA18URTAZ
ARSA25FMTAZARSA25UMTAZ
AUSA25FRTAZAUSA25URTAZ
AXSS18FHTA
Wall Mounted TypeWindow Type
ARSA40FMTBZARSA40UMTBZ
ARSA50FMTBZARSA50UMTBZ
ARSA60FHTBZARSA60UHTBZ
Cassette Type
AXSS24FHTC
Nonstop operation up to 52°C ambient Nonstop operation up to 60°C ambient
5
New Energy Labelling Requirement SASO2663/2014
The number of stars displayed on the energy label. Available stars are between a
minimum of one and a maximum of ten. It is considered as an indication of the claimed
energy efficiency of a model at rated conditions. A higher star rating indicates a higher
energy efficiency. It is derived from the actual measured EER. Our models have reached
the highest energy efficiency level that is now shown on energy labels in Saudi Arabia.
ENERGY EFFICIENCY CLASSIFICATION
HYPER TROPICAL SPEC
R22 depletes the ozone layer, however, R410A is energy efficient refrigerant with ODP “0”.
NEW REFRIGERANT
SASO2663/2014
R410A R22
EER
18.116.815.614.513.412.411.510 9.7 9 8.5
>>>>>>>>>>>>
EEREEREEREEREEREEREEREEREEREEREEREEREER
>
18.116.815.614.513.412.411.510 9.7 9 8.5 7.5 7.5
109.59
8.58
7.57654321
Energy rating classification Example of Label -Cooling only
Star RatingEER limits (rested value)
(Btu/h)/ w at T1
Temperature rise prevention device (thermal protector) installed.
Gas leak protection and low voltage protection OLP (Over Load Protection) device installed.
High-output torque motor Torque improved by increasing the thickness of the
laminated core and improving the coil winding.
High durability vaneSurface hardness increased.
High durability rolling pistonHardness improved by changing the material.
High durability crankshaft used Hardness improved by adding a coating.
1.Improvement of compressor drive materials for greater durability (Hardness increased).
2.Use of high efficiency, high torque motor
3.Complete protection functions against abnormal temperature rise and abnormal pressure rise
Main features
SUPER PROTECTION(for Split Type)
Enhancement of protection function
Strong blue finAdoption of strong blue fin provides strong protection against rust and salt damage.
Super powerMore capacity than current models under overload condition (52°C).(Window Type: 60°C)
Super low voltage operationOur Hyper Tropical Compressor can be operated even at low voltage.
Super Hi-EERHighly energy efficiency
Super quietSelect the lower noise level.
Designed by Fujitsu General the Japanese company whohas long term experience in air conditioning products
HYPER TROPICAL COMPRESSOR
PRODUCT SUMMARY
6
AXSS24FHTC
AXSS18FHTA
Energy saving and high performance are realized even at high outdoor temperature by using new refrigerant R410A and mounting large heat exchanger and new efficient rotary compressor.
R410A
WINDOW TYPE
SPECIFICATIONS AXSS24FHTC
6
AXSS18FHTA
EER
EER
7
Feature
Moisture Removal
Double Swing Automatic
Automatic Louvers
Auto Shut Louvers
Automatic Fan Speed
Auto Restart
Sleep Timer
Program Timer
Weekly Timer
Connectable Distributing Duct
Connectable Fresh Air Duct
Powerful Mode
Economy Mode
ARSA25FMTA ARSA25UMTAARSA18FMTA ARSA18UMTA ASSA18FETA ASSA18UETA
ASSA24FETA ASSA24UETAASSA30FMTA ASSA30UMTAASSA36FETA ASSA36UETA
ARSA40FMTB ARSA40UMTBARSA50FMTB ARSA50UMTBARSA60FHTB ARSA60UHTB
AUSA18FRTA AUSA18URTAAUSA25FRTA AUSA25URTAAUSA40FRTA AUSA40URTAAUSA50FRTA AUSA50URTA
Model
Program TimerThis digital timer allows selection of one of four options: ON, OFF, ON OFF or OFF ON
Auto RestartIn the event of a temporary power failure, the air conditioner will automatically restart in the same operating mode as before once the power supply is restored.
Economy ModeThermostat setting automatically changesaccording to the temperature to avoidunnecessary cooling and heating.
Moisture RemovalThe computer effectively dehumidifies the air.
Double Swing AutomaticComplex swing action of louvers enables automatically to swing both horizontal and vertical directions.
Auto-Shut LouversThe auto shut louvers close or open automatically when the unit stops or starts.
Weekly TimerDifferent on-off times can be set for each day.
Powerful ModeOperates at maximum airflow in the cool and fan operation modes, and quickly makes the room comfortable.
Sleep Timer The micro-computer gradually changes the room temperature automatically to help you enjoy a comfortable night's sleep.
Automatic LouversThe position of the louvers is set automatically to match the operating mode. The louvers can also be adjusted using the remote controller.
Automatic Fan SpeedThe micro-computer automatically adjusts the airflow effectively and properly according to the changes of room temperature.
FEATURE SUMMARY FOR SPLIT TYPE
EXPLANATION OF FEATURES
SPECIFICATIONS ASSA36UETAZASSA36UETA
AOSA36UETAS
ASSA36FETAZASSA36FETA
AOSA36FETAS
ASSA30UMTAZASSA30UMTA
AOSA30UMTAS
ASSA30FMTAZASSA30FMTA
AOSA30FMTAS
ASSA24UETAZASSA24UETA
AOSA24UETAH
ASSA24FETAZASSA24FETA
AOSA24FETAH
ASSA18UETAZASSA18UETA
AOSA18UETAH
ASSA18FETAZASSA18FETA
AOSA18FETAH
EER
EER
ASSA36FETAZ ASSA36UETAZ
ASSA18FETAZ ASSA18UETAZ
ASSA24FETAZ ASSA24UETAZ
ASSA30FMTAZ ASSA30UMTAZ
MODE SWING
SET
SET
TIMER
SLEEP
START/STT TOP
TEST RUNTTT RESETCLOCK ADJUST
FANFAN
TEMP
TEMP
MODE SWING
SET
SET
TIMER
SLEEP
START/STT TOP
TEST RUNTTT RESETCLOCK ADJUST
FANFAN
TEMP
TEMP
9
Powerful Cooling
Super High
High
Med
Low
Quiet
6 speed
*One touch powerful cooling mode: Continuous operation for 30 minutes at maximum air volume
10.19 Btu/hW
11.51 Btu/hW13% up
42% up
22,900 Btu/h
24,000 Btu/h5% up
Powerful
High
Med
Low
Quiet
5 speed
Powerful mode(30 / 36 class)
15m 25m
than current model (high mode)
25% up
Airflow
NEW model Current model
25m!
Temperature °C22.0 23.0 24.0 25.0 26.0 27.0
10m
10m
60cm
2.5m
Indoor temperature of 27°C DB, and outdoor temperature of 35°CDBSetting temperature:24°CDB, High airflow mode, 30 class CFD simulation results after 250 seconds from the start.
than current model
18% faster!
Reach the setting temp.
NEW model Current model
Powerful mode(30 / 36 class)
15m 25m
25m!
Reach the setting temp.
NEW model Current model
(Btu/h, 230V, 60Hz, T3 condition)
NEW model
(Btu/h, 220V, 60Hz, T3 condition)
Current model
(Btu/hW, 230V, 60Hz, T1 condition)
NEW model
(Btu/hW, 220V, 60Hz, T1 condition)
Current model
30 cooling model
30 cooling model
30 Heat & Cool model
8.10 Btu/hW
11.51 Btu/hW
Long-reach airflow up to 25m is provided by optimized airflow design.
Powerful airflow
6-Speed fan control with added Powerful Cooling mode is provided.* 30 / 36 class
More powerful fan speed control
Higher cooling capacity is achieved at the ambient temperature of 52°C condition.
Powerful cooling
New models accelerate to cool air quicker to reach the setting temperature in the entire room than the current models do.
Faster cooling
Higher EER is achieved by the new technologies and new refrigerant.
High energy saving
WALL MOUNTED TYPE
AUSA25FRTAZ AUSA25URTAZ
AUSA18FRTAZ AUSA18URTAZ
AUSA50FRTAZ AUSA50URTAZ
AUSA40FRTAZ AUSA40URTAZ
SPECIFICATIONS AUSA50URTAZAUSA50URTAAOSA50URTCS
AUSA50FRTAZAUSA50FRTAAOSA50FRTCS
AUSA40URTAZAUSA40URTA
AOSA40UBTCS
AUSA40FRTAZAUSA40FRTA
AOSA40FBTCS
AUSA25URTAZAUSA25URTA
AOSA25UBTBH
AUSA25FRTAZAUSA25FRTA
AOSA25FBTBH
AUSA18URTAZAUSA18URTA
AOSA18UBTBH
AUSA18FRTAZAUSA18FRTA
AOSA18FBTBH
11
*Option Wired RC (Touch Panel) only
* Comfortable air conditioning by preventing direct blowing of cold air and by providing swinging airflow simultaneously
*Efficient air conditioning in accordance with the room layout
New cassette series has achieved quiet operation and large air volume by unique circular flow design and offer quiet comfortable activities.
Quiet operation and Large air volume
Each louver can be set individually by Touch Panel Wired Remote Controller to enjoy the comfort of different directional airflows according to various room layouts.
Individual louver control(Option)
New cassette series has achieved 7-Star in SASO.High energy efficiency operation can be done.
ALL 7-Star models
AUSA**URTA
50402518
11.51 11.5011.52
AUSA**FRTA
50402518
11.51 11.50
18
11.54
18
11.5411.52
T1(Btu/hW)
AUSA**F(U)RTAAUSA**F(U)RTA
5040251818 25 400 50
43
35
44
35
4846
4946
50402518188 25 400 500
640
1150 1100 1150
1500
2000
1650
2100
Hi(dB) Hi(m3/h)
NEW model Current model
Comfortable!
Ø7mm high density heat exchanger
New DC fan motor
High efficient turbo fan
Seamless airflow louver
Achieve a comfortable air conditioning spread to every corner of the room by circular flow & wide vertical airflow.
Uniform temperature air conditioning
CASSETTE TYPE
New Cassette type realizes Circular Flow to blow large airflow in 360º direction by mounting high performance DC fan motor, new turbo fan and unique seamless airflow louver design.
Unique Circular Flow design
12
ALL 7-Star models
ARSA**UMTAARSA**FMTA
ARSA25FMTAZ ARSA25UMTAZ
ARSA18FMTAZ ARSA18UMTAZ
DUCT TYPE
SPECIFICATIONS ARSA25UMTAZARSA25UMTA
AOSA25UBTAH
ARSA25FMTAZARSA25FMTA
AOSA25FBTAH
ARSA18UMTAZARSA18UMTA AOSA18UBTAH
ARSA18FMTAZARSA18FMTA
AOSA18FBTAH
ARSA50FMTBZ ARSA50UMTBZ
ARSA40FMTBZ ARSA40UMTBZ
ARSA60FHTBZ ARSA60UHTBZ
SPECIFICATIONS ARSA60UHTBZARSA60UHTB
AOSA60URTBS
ARSA60FHTBZARSA60FHTB
AOSA60FRTBS
ARSA50UMTBZARSA50UMTBAOSA50URTBS
ARSA50FMTBZARSA50FMTBAOSA50FRTBS
ARSA40UMTBZARSA40UMTBAOSA40UBTBS
ARSA40FMTBZARSA40FMTBAOSA40FBTBS
4-Step of the static pressures can be selected by the remote controller.(40 / 50 : 30, 60, 90, 120 Pa) (60 : 60, 100, 130, 160 Pa)
Assemble again in ceiling
Separate on floor
Assemble again in ceiling
15
Air Stabilizer is provided to minimize loss of airflow which enables to reduce the power input of the fan motor.
(40 / 50 class)
Max.120Pa(60 class)
Max.160Pa
(40 / 50 class)
22% up
Heat-ExchangerVolume
(60 class)
13% up
Heat-ExchangerVolume
V-shape heat exchangerAir StabilizerTop view
The key technologies of V-Shape Heat-Exchanger and Air Stabilizer are provided as special features of this product.
Key Technologies for High Efficiency
The indoor unit is able to cover various duct designs thanks to the employment of DC fan motor.
Adjustable Static Pressure
As the indoor unit is too big to lift up to ceiling in the original structure, it can be separated on floor and assembled it again in the ceiling.
Separated Indoor unit (60 model only)
ARSA**UMTB / ARSA**UHTB
11.50
605040
ARSA**FMTB / ARSA**FHTB
605040
11.5011.52
40 60
11.50
50
11.5011.52
T1(Btu/hW)
New duct series has achieved 7-Star in SASO.High energy efficiency operation can be done.
ALL 7-Star models
DUCT TYPE
https://www.fujitsu-general.com/
Distributed by:
ountries or areas.
( d)
Remote Sensor UnitLong Life Filter
(for 18/25)
Flange (Round)
(for 18/25)
Flange (Square)
(for 18/25)
Wired Remote ControllerIR Receiver UnitWide PanelPanel Spacer
Insulation for High HumidityCommunication KitExternal Input and Output PCBExternal Input and Output PCB Box
Drain Pump Unit
(for 18/25)
Drain Pump Unit
For WALL MOUNTED TYPE For ALL MODEL
For CASSETTE TYPE
For DUCT TYPE
External Connect SetExternal Connect Kit
External Input and Output PCBExternal Input and Output PCB Bracket
Air Outlet Shutter PlateExternal Connect Kit
Wired Remote ControllerCommunication KitExternal Connect Kit Wireless LAN Interface
OPTIONAL