25
RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

  • Upload
    vuthuy

  • View
    215

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

RXS-F

Technical Data

E E D E N 1 2 - 1 0 0

O u t d o o r U n i t - P a i r a p p l i c a t i o n

Air Conditioners

Page 2: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Split - Sky Air • Outdoor Unit 1

• Outdoor Unit • Pair application • RXS-F

TABLE OF CONTENTSRXS-F

1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Nominal Capacity And Nominal Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Technical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

3 Electrical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

4 Capacity tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11Cooling/Heating Capacity Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

5 Dimensional drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17Dimensional Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

6 Centre of gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Centre of Gravity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

7 Piping diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19Piping Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

8 Wiring diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20Wiring Diagrams - Single Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

9 Sound data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Sound Pressure Spectrum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

10 Operation range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23Operation Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Page 3: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

11

• Split - Sky Air • Outdoor Unit2

1 Features

Outdoor Uni Split - Sk RXS-F Pair applic • Outdoor units for pair application

• Energy saving during standby mode: reduces current consumption by about 80% when operating In standby. If no people are detected for more than 20 minutes, the system will automatically switch to the current-saving mode.

• Daikin outdoor units are neat, sturdy and can easily be mounted on a roof or terrace or simply placed against an outside wall

• Outdoor unit silent operation: "silent" button on the remote control lowers the operation sound of the outdoor unit by 3dBA to ensure a quiet environment for the neighbourhood.

• Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency

Page 4: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

12

• Split - Sky Air • Outdoor Unit 3

• Outdoor Unit • Pair application • RXS-F

2 Specifications

Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 5m

Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 5m; level difference: 0m (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 5m; level difference: 0m

Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 7.5m; level difference: 0m (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 7.5m; level difference: 0m

2-1 Nominal Capacity And Nominal Input FTXS60G / RXS60F FTXS71G / RXS71F

Cooling capacity Min. kW 1.7 2.3Btu/h 5,800 7,800

Nom. kW 6.0 (3) 7.1 (3)Btu/h 20,500 (3) 24,200 (3)

Max. kW 6.7 8.5Btu/h 22,900 29,000

Heating capacity Min. kW 1.7 2.3Btu/h 5,800 7,800

Nom. kW 7.0 (4) 8.2 (4)Btu/h 23,900 (4) 28,000 (4)

Max. kW 8.0 10.2Btu/h 27,300 34,800

Power input Cooling Nom. kW 1.99 2.35Heating Nom. kW 2.04 2.55

EER 3.02COP 3.43 3.22Annual energy consumption kWh 995 1,175Energy label Cooling B

Heating B C

2-1 Nominal Capacity And Nominal Input FBQ60C8 / RXS60F

Cooling capacity Nom. kW 5.70 (3)Heating capacity Nom. kW 7.00 (4)Power input Cooling Nom. kW 1.75

Heating Nom. kW 2.05EER 3.26COP 3.41Annual energy consumption kWh 875Energy label Cooling A

Heating B

2-1 Nominal Capacity And Nominal Input FFQ60B9V / RXS60F

Cooling capacity Nom. kW 5.80 (3)Heating capacity Nom. kW 7.00 (4)Power input Cooling Nom. kW 2.07

Heating Nom. kW 2.49EER 2.80COP 2.81Annual energy consumption kWh 1,035Energy label Cooling D

Heating D

Page 5: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

12

• Split - Sky Air • Outdoor Unit4

2 Specifications

Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB; equivalent piping length: 5m; level difference: 0m (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 5m; level difference: 0m

Notes (1) Energy label: scale from A (most efficient) to G (less efficient) (2) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (3) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (4) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 5m

2-1 Nominal Capacity And Nominal Input FCQG60F / RXS60F

Cooling capacity Nom. kW 5.70 (3)Heating capacity Nom. kW 7.00 (4)Power input Cooling Nom. kW 1.64

Heating Nom. kW 1.99EER 3.48COP 3.52Annual energy consumption kWh 820Energy label Cooling A

Heating B

2-1 Nominal Capacity And Nominal Input FHQ60B8 / RXS60F

Cooling capacity Min. kW 1.7Btu/h 5,800kcal/h 1,460

Nom. kW 5.7 (3)Btu/h 19,400 (3)kcal/h 4,900 (3)

Max. kW 6.0Btu/h 20,500kcal/h 5,160

Heating capacity Min. kW 1.7Btu/h 5,800kcal/h 1,460

Nom. kW 7.2 (4)Btu/h 24,600 (4)kcal/h 6,190 (4)

Max. kW 8.0Btu/h 27,300kcal/h 6,880

Power input Cooling Min. kW 0.440Nom. kW 2.150Max. kW 2.230

Heating Min. kW 0.400Nom. kW 2.490Max. kW 2.750

EER 2.65COP 2.89Annual energy consumption kWh 1,075Energy label Cooling D

Heating DPiping connections Liquid OD mm 6.35

Gas OD mm 12.7Heat insulation Both liquid and gas pipes

Page 6: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

12

• Split - Sky Air • Outdoor Unit 5

• Outdoor Unit • Pair application • RXS-F

2 Specifications

Notes (1) Cooling: indoor temp. 27ºCDB, 19ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 7.5m (2) Heating: indoor temp. 20ºCDB; outdoor temp. 7ºCDB, 6ºCWB; equivalent refrigerant piping: 7.5m (3) Energy label: scale from A (most efficient) to G (less efficient) (4) Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (5) Cooling: indoor temp. 27ºCDB, 19.0ºCWB; outdoor temp. 35ºCDB, 24ºCWB; equivalent piping length: 5m (6) Nominal heating capacities are based on: indoor temperature: 20ºCDB, outdoor temperature: 7ºCDB, 6ºCWB, equivalent refrigerant piping: 5m, level difference: 0m. (7) When connected with multi-system outdoor unit, refer to the specifications of the multi outdoor unit to be connected.

2-1 Nominal Capacity And Nominal Input FDXS60C / RXS60F

Cooling capacity Min. kW 1.7 (3)Btu/h 5,800 (3)kcal/h 1,460 (3)

Nom. kW 6.0 (3)Btu/h 20,500 (3)kcal/h 5,160 (3)

Max. kW 6.5 (3)Btu/h 22,200 (3)kcal/h 5,590 (3)

Heating capacity Min. kW 1.7 (4)Btu/h 5,800 (4)kcal/h 1,460 (4)

Nom. kW 7.0 (4)Btu/h 23,900 (4)kcal/h 6,020 (4)

Max. kW 8.0 (4)Btu/h 27,300 (4)kcal/h 6,880 (4)

Power input Cooling Min. kW 0.440Nom. kW 2.130Max. kW 2.490

Heating Min. kW 0.400Nom. kW 2.320Max. kW 3.180

EER 2.82COP 3.02Annual energy consumption kWh 1,065Energy label Cooling C

Heating DPiping connections Liquid OD mm 6.35

Gas OD mm 12.7Drain OD mm 26Heat insulation Both liquid and gas pipes

2-2 Technical Specifications RXS60F RXS71F

Casing Colour Ivory whiteDimensions Unit Height mm 735 770

Width mm 825 900Depth mm 300 320

Packed unit Height mm 797 900Width mm 960 925Depth mm 390

Weight Unit kg 48 71Packed unit kg 53 80

Page 7: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

12

• Split - Sky Air • Outdoor Unit6

2 Specifications

Heat exchanger Length mm 845 857Rows Quantity 2Fin pitch mm 1.8 1.40Stages Quantity 32 34Tube type ø8 Hi-XA ø8 Hi-XSSFin Type Waffle louvered fin

Fan Type Propeller fanAir flow rate Cooling High m³/min 50.9 54.5

cfm 1,797 1,924Low m³/min 42.4 57.1

cfm 1,496 1,624Super low

m³/min -cfm -

Heating High m³/min 46.3 52.5cfm 1,635 1,854

Low m³/min 42.4 46.0cfm 1,496 1,624

Super low

m³/min -cfm -

Running current Cooling Low A 8.23 9.71Standard A 8.62 10.20High A 9.01 10.59

Heating Low A 8.41 10.44Standard A 8.80 10.93High A 9.19 11.42

Power consumption Cooling Low W 1,950 2,305Standard W 1,950 2,305High W 1,950 2,305

Heating Low W 1,995 2,490Standard W 1,995 2,490High W 1,995 2,490

Fan motor Model KFD-380-50-8C KFD-280-66-8AOutput W 53.00 66.00Speed Cooling High rpm 810 860

Low rpm 680 730Super low

rpm -

Heating High rpm 740 830Low rpm 680 730Super low

rpm -

Sound power level Cooling Nom. dBA 63 66Sound pressure level Cooling High dBA 49 52

Low dBA 46 49Heating High dBA 49 52

Low dBA 46 49Compressor Model 2YC36BXD#C 2YC36BXD#A

Type Hermetically sealed swing compressorOperation range Cooling Ambient Min. ºCDB -10

Max. ºCDB 46Heating Ambient Min. ºCWB -15

Max. ºCWB 20Refrigerant Type R-410A

Charge kg 1.5 2.3Refrigerant oil Type FVC50K

Charged volume l 0.65 0.75

2-2 Technical Specifications RXS60F RXS71F

Page 8: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

12

• Split - Sky Air • Outdoor Unit 7

• Outdoor Unit • Pair application • RXS-F

2 Specifications

Notes (1) 220V (2) 230V (3) 240V

Piping connections Drain ID mm -Piping length OU - IU Max. m 30

System Chargeless

m 10

Level difference IU - OU Max. m 20

2-3 Electrical Specifications RXS60F RXS71F

Power supply Phase 1~Frequency Hz 50Voltage V 220-240

Current Starting current Cooling A 9.4 11.7Heating A 9.4 11.7

Wiring connections For power supply Quantity 3For connection with indoor

Quantity 4Remark Earth wire included

2-2 Technical Specifications RXS60F RXS71F

Page 9: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

13

• Split - Sky Air • Outdoor Unit8

3 Electrical data3 - 1 Electrical Data

Page 10: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

13

• Split - Sky Air • Outdoor Unit 9

• Outdoor Unit • Pair application • RXS-F

3 Electrical data3 - 1 Electrical Data

Page 11: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

13

• Split - Sky Air • Outdoor Unit10

3 Electrical data3 - 1 Electrical Data

Page 12: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

14

• Split - Sky Air • Outdoor Unit 11

• Outdoor Unit • Pair application • RXS-F

4 Capacity tables4 - 1 Cooling/Heating Capacity Tables

Page 13: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

14

• Split - Sky Air • Outdoor Unit12

4 Capacity tables4 - 1 Cooling/Heating Capacity Tables

Page 14: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

14

• Split - Sky Air • Outdoor Unit 13

• Outdoor Unit • Pair application • RXS-F

4 Capacity tables4 - 1 Cooling/Heating Capacity Tables

Page 15: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

14

• Split - Sky Air • Outdoor Unit14

4 Capacity tables4 - 1 Cooling/Heating Capacity Tables

Page 16: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

14

• Split - Sky Air • Outdoor Unit 15

• Outdoor Unit • Pair application • RXS-F

4 Capacity tables4 - 1 Cooling/Heating Capacity Tables

Page 17: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

14

• Split - Sky Air • Outdoor Unit16

4 Capacity tables4 - 1 Cooling/Heating Capacity Tables

Page 18: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

15

• Split - Sky Air • Outdoor Unit 17

• Outdoor Unit • Pair application • RXS-F

5 Dimensional drawings5 - 1 Dimensional Drawings

Page 19: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

16

• Split - Sky Air • Outdoor Unit18

6 Centre of gravity6 - 1 Centre of Gravity

Page 20: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

17

• Split - Sky Air • Outdoor Unit 19

• Outdoor Unit • Pair application • RXS-F

7 Piping diagrams7 - 1 Piping Diagrams

Page 21: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

18

• Split - Sky Air • Outdoor Unit20

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

Page 22: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

18

• Split - Sky Air • Outdoor Unit 21

• Outdoor Unit • Pair application • RXS-F

8 Wiring diagrams8 - 1 Wiring Diagrams - Single Phase

∼∼

Page 23: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

• Outdoor Unit • Pair application • RXS-F

19

• Split - Sky Air • Outdoor Unit22

9 Sound data9 - 1 Sound Pressure Spectrum

Page 24: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

3

110

• Split - Sky Air • Outdoor Unit 23

• Outdoor Unit • Pair application • RXS-F

10 Operation range10 - 1 Operation Range

Page 25: Air Conditioners Technical Data - daikintech.co.ukA... · RXS-F Technical Data EEDEN12-100 Outdoor Unit - Pair application Air Conditioners

Naamloze Vennootschap - Zandvoordestraat 300, B-8400 Oostende - Belgium - www.daikin.eu - BE 0412 120 336 - RPR Oostende

Please fill out the requested informationPlease fill out the requested information

The present leaflet is drawn up by way of information only and does not constitute an offer binding upon Daikin Europe N.V.. Daikin Europe N.V. has compiled the content of this leaflet to the best of its knowledge. No express or implied warranty is given for the completeness, accuracy, reliability or fitness for particular purpose of its content and the products and services presented therein. Specifications are subject to change without prior notice. Daikin Europe N.V. explicitly rejects any liability for any direct or indirect damage, in the broadest sense, arising from or related to the use and/or interpretation of this leaflet. All content is copyrighted by Daikin Europe N.V.

Daikin’s unique position as a manufacturer of air conditioning equipment, compressors and refrigerants has led to its close involvement in environmental issues. For several years Daikin has had the intention to become a leader in the provision of products that have limited impact on the environment. This challenge demands the eco design and development of a wide range of products and an energy management system, resulting in energy conservation and a reduction of waste.

Daikin Europe N.V. participates in the Eurovent Certification programme for Air conditioners (AC), Liquid Chilling Packages (LCP), Air handling units (AHU) and Fan coil units (FCU), Check ongoing validity of certificate online: www.eurovent-certification.com or using: www.certiflash.com”

Daikin products are distributed by:

EED

EN12

-100

• 05

/12

• Cop

yrig

ht ©

Dai

kin

The

pres

ent

publ

icat

ion

supe

rsed

es E

EDEN

11-1

00Pr

inte

d on

non

-chl

orin

ated

pap

er. P

repa

red

by G

oeki

nt G

raph

ics

NV,

Bel

gium

Resp

onsi

ble

Edito

r: D

aiki

n Eu

rope

N.V

., Za

ndvo

orde

stra

at 3

00, B

-840

0 O

oste

nde

EEDEN12 - 1 00