AIR COOLED PACKAGED AIR CONDITIONERS Suitable for factories

AIR COOLED PACKAGED AIR CONDITIONERS - Daikin · AIR COOLED PACKAGED AIR CONDITIONERS DUCT TYPE RUR10NY1 FDR10NY1 RUR10NY1 FVGR10NV1 RUR10NY1 FVPGR10NY1 Enhanced varieties of factory

  • Upload
    others

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

AIR COOLED PACKAGEDAIR CONDITIONERS

Suitable for

factories

Page 15,16

Page 6Page 13,14

Page 15,16

1

Page 5Page 11

Page 5Page 12

Nice, cool air in the factory or in the cafeteria

2

DUCT CONNECTION TYPE

FLOOR STANDING TYPEDIRECT AIR BLOW TYPE

3

AIR COOLED PACKAGED AIR CONDITIONERS

DUCT TYPE

RUR10NY1FDR10NY1

RUR10NY1FVGR10NV1

RUR10NY1FVPGR10NY1

Enhanced varieties of factory modification and optional accesories

Standard model

Factory modification

Auto restart

Floor Standing Type

Fac

tory

Mod

ifica

ion

Direct Air Blow

DuctConnection

Type

Duct Type

Central control adaptor kit (external terminal for ON/OFF , abnormal)1 DAT107A55

Opt

ion

Modify wiring for central control adapter kit (DAT107A55) installation

Change fan motor and pulley

Discharge grill plenum chamber

Side discharge grillon discharge plenum chamber

Lower drain pan

Front suction high efficiency filter chamber

Suction grill for front suction high efficiency filter chamber

Fresh air inlet

Rear suction

Drain pump

BRC1C62LCD remote controller2

DCS601C51intelligent Touch Controller2

DCS302CA61Central remote controller2

DCS301B61Unified ON/OFF controller3

DST301BA61Schedule timer3

KRCS01-1Remote sensor (thermistor for suction air)3

BRC1NU64Remote controller

Remote sensor(Thermistor for suction air)

All fresh air application

Low outdoor temp.15ºC application and long pipe 70m application

Front suction base flange for front suction high efficiency filter chamber

Contact sales for more infomation

Note: 1Wiring modification is needed on floor stand model to connect with central control ADP kit.2Need to use central control adapter kit for option connection.3Central control adapter kit and LCD remote controller is necessary for option connection.

Equipped with scroll compressor for quiet operation

Smooth running, low vibration, low operating sound.

Quiet Operation

Outdoor unitSound level

59 dB

380V 415V

RUR05NY1

59 dB

60 dB

60 dBRUR06NY1

4

DurabilityHeat exchange fins provided with anti-corrosion treatmentTo achieve increased durability by improved resistance to salt corrosion and atmospheric pollution, coated PE fins (with special acryl pretreatment) are used for the heat exchanger of the outdoor unit.

(Applies to all outdoor units)

(Applies to RUR05N/06N)

Previous 20HP outdoor unit

Installation space is saved thanks to a more compact outdoor unit. This also makes it easier to install.

Space savings

RUG10AUY1 X 2RUR20NY1

(20HP)

NEW

2,560mm690mm

1,240mm765mm

space savedcompared to

previous model

53%

Refrigerant pre charged for up to 7.5 metres

Design flexibilityDesigned for long refrigerant piping. 50 m maximum length and 30 m maximum level difference to cover medium- and large-scale building needs.

Outdoor unit roof installation possible for plenty of leeway.

Allowable refrigerant pipe length and level difference

Max. leveldifference

Pre-charged 1 Max. length

30 m7.5 m 50 m(Equivalent length 70 m)

Note: 1Additional refrigerant charging is required if the refrigerant pipe is longer than the indicated length.

4-direction piping affords more freedom of layoutPiping can be run from the front, bottom, right or rear surface according to how the unit is installed.

In case of RUR08–20N, piping can be drawn out in two directions-front, and under side.

Max. length

Max. level difference

RUR05NY1-20NY1

Easy operationDigital remote control comes standard with indoor unit.

Temperature setting is possible by button operation. The set temperature is conveniently displayed on the LED.

1453

6789

210

1

2

3

5

6

7

89

Note.1

Note.1

4

1 Power

3 Temperature setting

2 Temperature scale

4 Mode setting

5 Next setting

6 Fan indicator lamp

7 Cool indicator lamp

9 Compressor 1 indicator lamp

10 Temperature sensor

8 Compressor 2 indicator lamp

1 On/Off button

3 Temp. setting up

2 Fan button

4 Temp. setting down

5 Mode button

6 LED display

7 Compressor operation lamp.

8 Fan operation lamp.

9 Cool operation lamp.

Note.1 It cannot be used for FVPGR10–20NY1

(Standard accessory)Floor standing type

(optional accessory)Duct type

X X

X X

X X

X X

X X

X X

X X

X X

X X X XX X

X X

5

X X

X X X X

X X X XX X X X

X X X X

X X X X

X X

6

X X

X X

X X

X X

7

Fan Performance

8

9

Wiring and Piping

10

DIMENSIONS

DIMENSIONS

11

12

DIMENSIONS

13

14

DIMENSIONS

15

16

When there are obstructions on the inlet side and both lateral sides

When there are obstructions on both sides

When there is an obstruction only on the inlet side

When there are obstructions on both sides

When there is an obstruction on the inlet side

When there are obstructions on the inlet side and both lateral sides

An obstruction in the overhead space

An obstruction in the overhead space

An obstruction in the overhead space

An obstruction in the overhead space

An obstruction in the overhead space

17

or more

or more

or moreor more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more

or more or more

mm

mm

or more

or more

or more

or more

or more

or more

or more

or more or more

or moreor more

or more

or more

or more

or more

or more

or more

or more

or more or moreor more or more

or more or more

or more

or more

or more

or more

or more

or more or more

or more

or more or more

18

Warning