11
Air Monitoring Program BoRit Site Kristine Matzko, EPA BoRit CAG meeting December 5, 2012

Air Monitoring Program BoRit Site

  • Upload
    daw

  • View
    32

  • Download
    0

Embed Size (px)

DESCRIPTION

Air Monitoring Program BoRit Site. Kristine Matzko, EPA BoRit CAG meeting December 5, 2012. Air Monitoring. EPA performed air monitoring in response to community request Evaluate air quality in community Use data in health assessment Sampled 7 locations - PowerPoint PPT Presentation

Citation preview

Page 1: Air Monitoring Program BoRit Site

Air Monitoring ProgramBoRit Site

Kristine Matzko, EPABoRit CAG meeting December 5, 2012

Page 2: Air Monitoring Program BoRit Site

Air Monitoring

• EPA performed air monitoring

– in response to community request

– Evaluate air quality in community

– Use data in health assessment

• Sampled 7 locations

– 6 locations in community and 1 background

– Local business, adult center, church, post office

Page 3: Air Monitoring Program BoRit Site
Page 4: Air Monitoring Program BoRit Site

Air Monitoring

• Sampled 12 months

– November 2010 to October 2011

– Sampled during every season

• 24 hour sample

– Collected samples on weekdays, weekends

– Collected during dry weather, not after rain

• Collected 14 samples at most locations

– sampled 2 times in August and October 2011

• Collected a total of 98 samples

Page 5: Air Monitoring Program BoRit Site
Page 6: Air Monitoring Program BoRit Site
Page 7: Air Monitoring Program BoRit Site
Page 8: Air Monitoring Program BoRit Site

Air Monitoring

• Analyze samples - microscope

– high powered electron microscope

– Identify asbestos fibers

• Count fibers - use method called PCME

– Count fibers of a specific length, dimension

– EPA’s method to assess health effects

• Compare results to screening value

– 0.001 structures/cubic centimeter (s/cc)

– EPA’s Asbestos Framework

– Consult with EPA’s risk assessor

Page 9: Air Monitoring Program BoRit Site

Location PCME – asbestos fibers Date

#1 trail along creek 0.001 s/cc Monday, Sept 12, 2011

#2 post office No detections

#3 church No detections

#4 adult center 0.0008 s/cc Friday, August 12, 2011

#5 business No detections

#6 background No detections

#7 warehouse 0.0008 s/cc Friday, August 12, 2011

Page 10: Air Monitoring Program BoRit Site
Page 11: Air Monitoring Program BoRit Site

Summary

• Year long monitoring, 98 samples

• 3 detections using the PCME method

• Detections during summer months

– August and September 2011

• The detections at or below the screening value of 0.001 s/cc

• EPA will evaluate the air data further

– Use data in the health assessment