    airfow management solutions

    predictability, reliability & eciency or your data center

  • 8/6/2019 Airflow Management Brochure

    2/16800.225.7348 www.wrightline.com

    For years, data center managers have been told they can

    either have a highlyreliable data center or a highlyefcient

    data center, but not both. Its a similar story to the automobile

    market where or decades, Detroit told the world, you caneither buy a low cost or a high quality car. The Japanese

    showed the world that you can indeed oer a car that is both

    low cost and high quality, changing the dynamics o the car

    industry orever.

    At Wright Line, we oer solutions that improve both

    eciency and reliability. In order to eectively uture proo

    your critical inrastructure you must maintain a predictable

    environment. This not only includes the ability to direct and

    separate hot and cold air, but also to accurately measure the

    perormance o your design to ensure it is operating

    as planned.

    Wright Lines comprehensive portolio o vendor-neutral

    airfow management solutions are designed to work within

    your new or existing data center environment. Whether you

    have Wright Line enclosures, an alternative brand or a mixo enclosures rom various manuacturers, these products

    will help solve your airfow management issues and provide

    a much more predictable operating environment which is

    essential to delivering both eciency and reliability.

    Although it is always important to look at the entire data

    center when optimizing airfow, solutions can be implemented

    in stages at the rack, row and room level depending on:

    Theproblemsyouarelookingtoaddress

    Thebudgetconstraintsyouareoperatingunder

    Thetimeframeinwhichasolutionisrequired

    Wright Lines Innovative Airow Management Solutions:

    Through the separation of hot and cold air, you dramatically increase the

    predictability of your data center s performance thereby enabling you to:

    Moreeffectivelyandefcientlyutilizeexistingphysicalinfrastructure

    and cooling capacity

    Activelycontrolandnormalizesupplytemperature;eliminating

    recirculationandstratication Domorewithlessinasmallerdatacenterfootprintwithincreasing

    high-density IT loads

    Eliminatestranded physical, electrical or mechanical capacity

    Fromheatcontainmentandcold-aisleisolationtototalairow

    managementbestpractices,WrightLinecanhelpimproveyourphysical

    ITinfrastructurebyprovidingeco-friendlysolutionsthatwillincreaseyour

    neworexistingdatacentersefciencyandreliability.

    Table of Contents:

    Heat Containment System Products 3-6

    Independent Containment System 7

    EndofRowDoors 8

    AisleContainmentCeiling/Duct 9

    EndofRowCurtains 10

    CRACCollars 10

    BlankingPanels 11

    AirowDirectors/Managers 12

    HighFlowDoors 13

    UniversalAirSealKit 13

    TowerofCool 14

    RaisedFloorGrommets 14

    CFDModelingServices 15

    Ask your account representative or more inormation.

    The Optimized Data Center

    sComputational Fluid Dynamics (CFD) model o an optimized data center illustrating cold-aisle isolation and Wright Lines

    Heat Containment System (HCS). See CFD Services on Page 15 or more inormation.

  • 8/6/2019 Airflow Management Brochure

    3/16800.225.7348 www.wrightline.com

    Heat Containment System (HCS)

    or Paramount and Vantage S2 enclosure systems

    sHCS allows or your existing cable management without the

    interruption o re-routing or disconnecting cables and power. HCS

    shown here on Wright Line's Paramount enclosure system.

    sWright Line's Paramount enclosure with integrated HCS.

    PhotocourtesyofHumana

    Wright Line's Heat Containment System (HCS) is a simple, scalable and low cost solution to

    cool up to 25kW or more per enclosure without the expense o adding supplemental CRAC

    units to your data center. This patented technology is available on Wright Line's Paramount

    and Vantage S2 enclosure systems and can also be eld retrotted to most manuacturers'

    enclosures. The HCS contains and directs the heat exhaust o your IT equipment through

    the chimney that is attached to the top rear o the enclosure. The hot air is then ducted to

    your existing CRAC units through the plenum ceiling or high air returns.

    Chimney

    Chimney base

    Optional ans (2)

    See Page 4

    Tool-less an access door

    s

    s

    s

    s

  • 8/6/2019 Airflow Management Brochure

    4/16800.225.7348 www.wrightline.com

    Heat Containment System (HCS)

    sComputational Fluid Dynamics (CFD) model showing

    airow through active HCS System.

    sBy using two optional ans, you can

    increase your airow up to 2,600 CFM.

    Wright Line's HCS is:

    ScalableItcanbeadaptedtoexistinginfrastructurestoincreaserackutilizationasyourcapacitydemandsgrow.

    PredictableItseparateshotexhaustairandcoldsupplyair;dramaticallyincreasingthereliabilityofthedatacenter.

    EfcientAllowinghotterairtoreturndirectlytotheCRACs,increasingtheirefciencybyoperatingatahigherDeltaT(T).

    ReliableItextendsexistingcoolingcapacitythroughoutthedatacenter;freeingupstrandedassetsandloweringoperationalcosts.

    FlexibleItdoesnotrequireyoutoalterexistingenclosurelocationsandisalsoeld-installableonthird-partyenclosures.

    HCS Flexible Return Duct

    For data centers unable to accommodate steel chimneys, an alternative

    solution or controlling chaos cooling is Wright Lines new Flexible

    Return Duct. A simple interace easily connects to the top o the Heat

    Containment System chimney. Flexible 10" ducts are clamped to the

    interace and a 2' X 2' ceiling tile , which is mounted to the plenum ceiling

    to create a closed loop system.

    DuctingisV-0ratedandselfextinguishing. CeilingtileisavailableinNugreytomatchexistingtiles.

    Ductingcanbecutintheeldforcustomts.

    Eachductcomeswithfourclamps.

    Ductsarepositioneddirectlyoverthefanformaximumairow.

    sThe ideal solution or clients having enclosures that are o-grid

    rom drop ceilings, where obstacles preclude the use o sheet metal

    chimneys or have uneven ceilings throughout their data center.

  • 8/6/2019 Airflow Management Brochure

    5/16800.225.7348 www.wrightline.com

    Bypass airfow and mixing lead to ineciencies, shorter

    lie cycles or equipment and increased operating cost.

    Managing airfow to enclosures with varying densities,

    varying building inrastructure and sporadic hot spots ischallenging, but can now be solved using a simple solution.

    Wright Lines HCS pressure based system with active

    airfow, when combined with best practices, improves

    perormance metrics considerably. Allocating the correct

    amount o airfow at known intake locations is the key toreducing energy consumption while increasing equipment

    perormance. Best practices such as blanking panels, proper

    perorated tile placement and the reduction o bypass

    airfow must be employed to ensure desired results.

    Active Thermal Management System

    Active Airfow Manager

    Features & Benets:

    SNMPmanageddevicewithuser-friendlywebinterface.

    Controllercontinuouslymonitorspressuredifferentialsto

    ensurethatairenteringtheenclosureandserveris

    properlyremoved. LocalLEDsindicatefanstatusincludingfanfailand

    overtemperature.

    Manageupto64PeerActiveAirowManagers

    viaEthernet.

    TwointegratedtemperaturesensorswithEmail

    alertcapabilities.

    Redundantpowerinput;C13plugtypeisrequiredfor

    eachinput,90-240VACsuppliedbyenclosurePDU(s).

    ControllerisRoHScompliant.

    Features & Benets:

    Dual90-264VACInput(C14).

    1Urack-mountapplication.

    Uptofourtemperatureprobesandoneinternalprobe.

    Webaccess,EmailandSNMPalerts.

    Displayindicatestemperature,operating

    setpointandfanspeedpercentage.

    sThe Active Airow Manager easily mounts inside a HCS chimney

    base. This device measures pressure dierentials and temperature to

    regulate an operation.

    sWright Line's Active Thermal Management System manages

    power to your an systems in a 1U orm actor. Works with

    optional ans shown on Page 4.

    Manage power to your an systems based on a set operating

    temperature. The ATMS-I (Active Thermal Management

    System) has dual 90-264 VAC input or redundancy in a 1Urack-mount enclosure. Connect up to our temperature

    probes and select operating temperature or automatic an

    speed adjustment. The local display indicates temperature,

    operating set point and an speed percentage.

  • 8/6/2019 Airflow Management Brochure

    6/16800.225.7348 www.wrightline.com

    Heat Containment System

    or third-party enclosure systems

    Features & Benets:

    Scalable Heat ContainmentImplementheatcontainmentwithminimal

    interruptiontooperationsbybuildingupfromexistingenclosureswithout

    havingtore-routeordisconnectcablesandpower.

    Increased Rack CapacityByisolatingthehotexhaustairfromthecold

    supplyair,youcanloadover25kWofequipmentinanenclosure.

    Save White Space No additional air conditioners or other space

    consuming supplemental equipment is required at the perimeter of the data

    center,in-roworoverhead.

    Increase CRAC Cooling EfciencyHotexhaustairisdirectedbacktotheCRACintakeatahigherTallowingyourACunitstooperatemoreefciently.

    Greatforyour"green"initiatives.

    Create a Predictable EnvironmentEliminatingchaosairowwillresult

    inamorepredictableoperatingenvironment,allowingyoutodriveefcient

    energyusewhilecreatingareliableinfrastructureforconstanttechnology

    moves,additionsandchanges.

    sBy adding the Wright Line Heat Containment System to your existing enclosures, you realize

    enormous equipment and cost savings while maintaining your valuable data center space.

    Shown here on APC, CPI, Rittal, Compaq and Knurr enclosures.

    Converting existing enclosures to

    the HCS allows you to eliminate the

    incremental capital expense associated

    with having to add more CRAC units

    or other supplemental cooling. The

    HCS manages the hot air exhaust,

    which prevents mixing, thereby

    allowing the available cooling already

    produced by your AC units, to be

    used much more eciently. Optional

    ans eliminate the issue o backfow

    rom a pressurized plenum, generallyassociated with passive-only systems.

  • 8/6/2019 Airflow Management Brochure

    7/16800.225.7348 www.wrightline.com

    Independent Containment System

    Features & Benets:

    Scalable DesignTheabilitytoextendaisleswithload

    growthmakestheICSanidealsolutionforco-locationand

    otherhighlyevolvingdatacenterenvironmentsthatrequire

    on-the-ymodications.

    Containment IntegrityVerticalblankingpanelsensure

    containmentintegritywhenracksarepartiallydeployed

    withintherowandareeasilyremovedinsectionstoallow

    quickinstallationandpositioningofnewITracks.

    Rack AgnosticAbilitytosupportvirtuallyanybrandof

    serverornetworkrackinanydepth,heightandsizewith

    on-demandrecongurationoftherow.

    Cold Aisle CompatibleEasilydeployedasacold

    aislecontainmentsolutionwithorwithoutadownow

    chimneysystem.

    Increased ROIModular,building-blockdesignoffers

    completeexibilityandroomforgrowthincreasingyour

    initialReturnonInvestment(ROI).

    sCeiling structure allows or the installation o additional 2' x 2'

    chimneys as IT loads increase.

    The culmination o Wright Line containment

    strategies is its patent-pending Independent

    Containment System (ICS), a ree-standing, scalable,sustainable and vendor-neutral containment solution

    or high-density computing environments.

    Designed to provide maximum fexibility in all

    environments, the ICS, assembled within the

    ootprint o a standard aisle, is constructed with

    a tubular steel rame. The rames structure is

    designed to be reestanding and meets seismic

    NEBSZone4standards.Additionally,itacceptsa

    varietyofWrightLinesEndofRowDoors(p.10)

    including ca style and single-swing models.

    Aisle ceilings (p. 11) are constructed o a light-weight

    steel rame and clear Lexan panels allowing ambient

    room light to illuminate the ICS aisle, eliminating the

    need or energy-consuming supplemental lighting.

    The ceiling accepts 2' x 2' adjustable chimneys which

    can be added anywhere on the ceiling structure as

    IT loads increase.

    sShown above Independent Containment System eaturing End o

    Row, Ca-style doors and vertical blanking to accommodate third-party

    enclosures.

  • 8/6/2019 Airflow Management Brochure

    8/16800.225.7348 www.wrightline.com

    EndofRowDoorsareasimple,cost-effectivesolutionto

    improve eciency while lowering overall operating costs.

    End o Row Doors

    Features & Benets:

    Ease of Installation Field-installable, rack-integrated and

    freestandingoptionsavailable.

    Rack AgnosticFlexibleenoughtoinstallalmostanywhereon

    anymanufacturer'sbrandenclosure.

    Improve Efciency and Predictability Increases cold air

    intakeefciency,fromthebottomoftheenclosuretothetop,

    withinthecoldaisle.Decreasewastedairbyasmuchas70%.

    Variety of Door Models Choose from three styles of

    doors from simple containment curtains to building-integrated

    caf-styledoorsandcontainmentwalls.

    Minimize Air Re-mixingCost-effectivelyminimizeair

    mixingbetweenthehotandcoldaislewhilekeepingthe

    uniformcoldairsupplyinfrontoftheserversforalonger

    periodoftime.sCa style doors allow or easy, hands-ree access to the row.

    sWright Line's End o Row Doors solution helps achieve aisle containment.

    Industry studies indicate that an estimated

    60% o the cool air supplied to traditional

    data centers is wasted because it bypasses theintended IT equipment and returns directly to

    the hot air intake o the CRAC. Adapting a

    containment strategy increases the eectiveness

    ofthecoldair.Eliminatingwastedaircaneither

    reduce the amount o cold air you need to

    supply to the data center or it can allow you to

    increase your IT load.

    EndofRowDoorscreatemoreefcientcold

    aisles by blocking an obvious cold-air escape

    route and entry or hot air re-circulation and airmixing. This allows you to set a higher overall

    temperature within the data center and enables

    air-side economization to be used a greater

    percentage o the time.

  • 8/6/2019 Airflow Management Brochure

    9/16800.225.7348 www.wrightline.com

    Aisle Containment Ceiling and Duct

    sThe Aisle Containment Ceiling's Lexan panels are cut to size or

    your specifc requirements and can be "nested" or adjustable widths.

    Wright Line's Aisle Containment Ceiling is comprised o V-0 rated Lexan panels

    and mounts easily to the top o Paramount, Vantage S2 and third-party enclosures.

    The ceiling system can accomodate dierences in rack heights, row spacing and it's

    sel-supporting structure allows or easy rack changes within the row. Holes can be

    strategically drilled in the panels to accommodate any type o re suppression system.

    The rack-integrated Aisle Containment Duct

    works seamlessly with the Aisle Containment

    Ceiling system. Integration with the air

    conditioning supply or exhaust is easily achieved

    with the duct's modular and scalable design.

    sThe Aisle Containment Ceiling, used in conjunction with the Aisle Containment Duct and

    End o Row Doors, completes Wright Line's total aisle containment solution.

    sThe Aisle Containment Duct is modular

    and scalable to ft your unique requirements.

  • 8/6/2019 Airflow Management Brochure

    10/16800.225.7348 www.wrightline.com

    End o Row Curtains

    CRAC Collars

    Given the ever increasing heat loads in todays data centers, solutions that

    eectively control airfow dynamics are in high demand. At a minimum,

    partially containing air within the aisle will not only increase the lie oyour valuable IT equipment but help decrease your rising energy costs.

    EndofRowCurtainsallowyoutocreateandmaintainproperaisle

    isolationinyourdatacenter.Dependingonyourspecicneeds,Endof

    Row Curtains can be installed at the rack level, with or without an Aisle

    Containment Ceiling, or rom foor to room ceiling.

    The CRAC Collar or downfow systems, used

    in conjunction with data center containment

    strategies is integral to Wright Lines total

    containment solution. By containing and directing

    the warm plenum air directly to your air

    conditioning systems, you increase eciency and

    equipment perormance while reducing overall

    energy consumption.

    The CRAC Collar eatures an integrated design,

    comprised o steel panels that mount easily to

    the top o any CRAC unit with easy, tool-less

    installation. Collars allow ront lter installation

    and service and completely integrate with airfow

    dampening devices. This closed-loop integration

    o the air conditioning supply or exhaust

    completes the modular airfow containment

    strategy in the data center, resulting in a more

    energy-ecient operation.

    sEnd o Row Curtains easily mount to

    enclosure tops with a mounting bracket.

    HTool-less access panels allow quick and easy installation on

    your existing CRAC units.

    HHinged access panels allow or easy cleaning, flter replacements and

    maintenance. Shown here with optional Backow Bae.

    cold aisle

    hot aisle

    CRAC

    cold aisle

    Typical data center confguration using

    oor to ceiling curtains to acheive total

    cold aisle isolation.

    s

  • 8/6/2019 Airflow Management Brochure

    11/16800.225.7348 www.wrightline.com

    In today's dynamic data center environment, IT

    equipment is rereshed on a requent basis. These

    changes oten leave open U-space in the enclosurewhich can allow re-circulation o hot exhaust air back to

    the equipment inlet. This can cause overheating o the

    equipment and subsequent shutdown o servers when

    the maximum temperature threshold is reached.

    Blanking panels provide a quick, easy and cost-eective

    solution to optimize air circulation within an enclosure

    while maintaining high aesthetics. Wright Line oers

    blanking panels in a variety o styles including tool-less,

    mechanically astened, clear and with cable pass through

    options in steel as well as plastic . The width meetsEIA-310-Dstandardsandcomesinvariousheights

    (depending on style). Most panels are bulk packed in

    quantities o 10 and 100.

    Blanking Panel Solutions

    Features & Benets:

    Signicantlyreducesre-circulationofhot

    exhaustairtotheequipmentinlet

    Addstotheoverallaestheticsofthedatacenter

    1U,2U,3U,4U,5U,6U,7U,8Uand20U

    (dependingonstyle)

    EIA-310-Dcompliantfor19"equipment

    Color: Black steel, black plastic, clear plastic

    Availableintool-less,mechanicallyfastened,clear and cable pass through styles

    sTool-less plastic blanking panels are a low cost but necessary solutionor preventing re-circulation and optimizing airow in your rack.

    sBrush strip models allow routing o cables through the panel.

    sVertical blanking panels seal open spaces and prevent bypass airow

    in areas that are traditionally difcult to seal. They can also be adapted

    or cable management.

    sAdjustable blanking panels, oered in two sizes (7-12U,

    12-22U) easily adapt to your hardware requirements.

  • 8/6/2019 Airflow Management Brochure

    12/16800.225.7348 www.wrightline.com

    Properly cooling network devices that require side-to-side airfow in an enclosure

    can present many challenges. Air recirculation that occurs in an enclosure can cause

    temperatures to rise signicantly causing overheating o the devices. Wright Line'sAirfow Managers and Directors draw air into the enclosure, redirect the air to the

    side intake o the device and allow the removal o the hot air out o the enclosure.

    These solutions extend equipment lie by providing proper inlet temperatures and

    eliminating harmul recirculation within the rack.

    The Airfow Director is designed or

    Cisco6509/6513/9513andJuniper

    8216 switches that have side-to-side

    cooling. The intake allows cold air to

    be drawn rom the cold aisle, through

    the Airfow Director and to enter theswitch rom the side. The switch's

    ans then pull the cool air across the

    device and exhaust the warm air out

    the opposite side.

    The Airfow Manager is designed to be used on Cisco Catalyst 4948

    switches.ItcanbeutilizedinmostenclosuresthatmeettheEIA-310-D

    specication.

    The Airfow Manager kit includes everything needed to mount the switch,control airfow and manage cabling. This 2U device can be mounted to

    ace either the hot or cold aisle while properly directing airfow.

    Airfow Directors / Managers or Side-intake Switches

    Features:

    Helpseliminateoverheatingofnetworkracksandothernearby

    equipmentbyallowingfront-to-rearairowthroughtheswitch.

    Improvesefciencybypreventinghotexhaustairfrommixing

    withcoldintakeair.

    Resolvesthedifcultissueofhowtomountaswitchwithunique

    airowrequirements.

    sOverhead view o Airow Manager

    with optional Cable Manager.

    sAirow Director or Cisco and Juniper switches.

    sAirow Manager or Cisco 4948 switch.

    sSide view o Airow Director.

  • 8/6/2019 Airflow Management Brochure

    13/16800.225.7348 www.wrightline.com

    Wright Lines High Flow Doors oer exceptional airfow with 75%

    peroration, a 19% increase over the industry standard. In addition to

    increased perormance, the unique peroration pattern results in a reduction

    o raw material consumption by over 60% which means less waste in the

    manuacturing process a great green benet.

    Doors are available as let or right hinged and are also eld

    reversible. The High Flow peroration is also available or

    the rear door and can be ordered as ull or split. The doors

    eature tool-less door removal, a brushed aluminum door

    pull and a variety o locks.

    Paramount High Flow Doors

    Universal Air Seal Kit

    Stop the cold air rom escaping through small openings in the doors,

    sides, bottom or top o your enclosure. This low cost, adaptable oam

    solution can quickly be sized to t into any crack or opening. The Air Seal

    Kit can easily be retrotted to an existing rack, regardless o manuacture,

    and will allow you to cool equipment more eciently in your enclosure.

    sReducing bypass airow and particulate matter is critical to maximize

    efciency, contain cost and minimize carbon ootprint in the data center.

    sWright Line's Air Seal Kit is

    a simple, inexpensive solution

    or preventing bypass airowin gaps around or within

    enclosures.

    Features & Benets:

    Easytoinstallandconformstospacesthataretraditionallydifculttoseal

    AnintegralcomponentofWrightLine'sAirowManagementSolutions,

    thisproductreinforcesthecompany'scommitmenttooffercosteffective

    green solutions

  • 8/6/2019 Airflow Management Brochure

    14/16800.225.7348 www.wrightline.com

    KoldLok Raised Floor Grommets

    By installing KoldLok Raised Floor Grommets, you

    can optimize the eectiveness o existing cooling

    equipment and manage increasing heat loads.

    The patented KoldLok sealing system specically

    addresses bypass airfow and its detrimental eect

    on data center cooling.

    Features & Benets:

    Eliminateupto98%ofbypassairow.

    Increasestaticpressureandairow

    throughperforatedoortilesandgrates.

    Bleedstaticchargebuildupoffofcables.

    Easy,tool-lessinstallation,requiringno

    downtimetoinstallorre-cable.

    sExtended raised oor grommet or

    long, narrow, above-oor perimeter cuts.

    sIntegral raised oor grommets installed in oor

    tiles prior to equipment installations.

    For applications where a ull HCS deployment

    is unnecessary, the patented Tower o Cool,

    which utilizes High Delta Temperature Cooling(HDTC), can be a perect alternative. The

    Tower o Cool eciently cools 10kW o

    equipment within 44U, by incorporating

    the building air conditioning system and

    the enclosure into one closed-loop cooling

    system. The Tower o Cool is also the perect

    solution or providing supplemental spot

    cooling in legacy data centers.

    By preventing stratied air rom entering

    the top o the enclosure, the Tower o Cooldistributes cold air which allows equipment

    to run at lower temperatures, resulting in

    increased hardware reliability.

    Paramount Tower o Cool

    sThe Tower o Cool,

    using specialized doorsand ans, captures cold

    air rom the raised oor

    plenum and distributes itthroughout the rack.

  • 8/6/2019 Airflow Management Brochure

    15/16800.225.7348 www.wrightline.com

    Wright Lines innovative Computational

    Fluid Dynamics (CFD) Modeling Service

    provides a comprehensive approachto modeling the airfow, temperature,

    static pressure and energy prole o

    dynamic, critical environments. Using

    Future Facilities 6SigmaDC sotware,

    we construct a virtual representation

    o your data center. This representation

    models the impact o load distribution

    within the acility, as well as the fow o

    hot and cold air within the space. It also

    illustrates how to increase rack densities

    and server installations without creatingadditional hot spots and airfow issues.

    Providing act-based decisions aimed

    at improving operational eciency and

    reliability, the CFD modeling analysis is

    essential or creating and operating a

    more predictable data center.

    The service compares and substantiates

    which design decisions will maximize

    your data center fexibility, scalability and

    resilience. It enables you to explore thebest possible options or IT and acility

    growth, create a calculated plan and

    avoid major capital commitments and

    costly design/implementation mistakes.

    Pricing or Wright Lines CFD Services is based on specic

    customer requirements and there are several levels o customized

    service a customer can choose rom. A pre-quote consultationand/or walk-through by a Wright Line CFD Team member is

    advised to determine the scope and level o CFD service required.

    Features:

    Fourlevelsofservice.

    State-of-the-artsoftwareandtools.

    Certiedtechnicians.

    Detailedreporting.

    Computational Fluid Dynamics Modeling Services

    sStream line plot showing temperature o air as it ows throughout the data center.

    Plots can be animated to illustrate direction o ow.

    sWright Line can provide extensive perormance

    details o your entire data center down to specifc

    devices at the rack level.

    sIllustration shows synchronized comparison o rack inlet temperatures

    beore and ater HCS deployment.

  • 8/6/2019 Airflow Management Brochure

    16/16

    Wright Line is a leading designer and

    manuacturer o products and solutions or

    data centers, command/control environments,

    technical labs and government oce settings.

    Incorporating expertise in airfow management

    and data center containment, modular

    workstation design and green standards,

    Wright Line helps customers conserve capital,

    adhere to technology requirements and

    address sustainable energy needs.

    Wright Line LLC

    World Headquarters

    160 Gold Star Boulevard

    Worcester, MA 01606

    Tel: 800-225-7348

    508-852-4300

    Fax: 508-365-6178

    www.wrightline.com

    [email protected]

    TAB Canada

    130 Sparks Avenue

    Willowdale, Ontario

    M2H 2S4

    Tel: 800-667-4020

    Fax: 888-257-5205

    For additional international representation,

    pleasecontactusat800-225-7348or

    [email protected].

    PleaseaskfordetailsofotherproductsfromWrightLine.Allproductsand company names are trademarks or registered trademarks of theirrespectiveholders.Everyefforthasbeenmadetoensurethattheinformationcontainedhereiniscorrect.Thecompanyreservestherighttomodifyproductspecicationswithoutpriornoticeandassumesnoresponsibilityforanyerrorwhichmayappearinthispublication.

    Wright Line LLC 201009-17/WP-5K/4-10 Printed in the USA

    Also see our ull line o products or

    high-perormance workplaces.

    Prole Advanced

    Console System

    Brochure

    Optimedia

    Storage System

    Brochure

    Contract No: GS-29F-0100G

    Schedule 71 I:

    OfceFurniture

    SIN 711-2: Workstations,ComputerFurniture&Accessories

    SIN 711-3:Filing & Storage Cabinets

    SIN 711-94: Design&LayoutServices

    SIN 711-95: InstallationServices

    Contract No: GS-07F-0546T

    Schedule 66:

    ScienticEquipmentandServices

    SIN 566-1: ModularLaboratoryFurnitureSystems

    SIN 566-2: IndividualNon-ModularLaboratoryTables,

    Cabinets, Benches & Carts