Upload
adil-abdo
View
67
Download
2
Tags:
Embed Size (px)
DESCRIPTION
The Airwell Group has a long history,marked by innovations at everystage of its development. In 1947Paul Wallet founded the companyL’Air Conditionné Entreprise (ACE)near Paris and, with the brandAirwell, quickly became the leadingmanufacturer of direct-expansion airconditioners. The foundations hadbeen laid for what would becomeone of the largest groups worldwideto offer solutions for both theresidential sector and to businesses,industry and the service sector.
Citation preview
light commercialcollection2012
2 3
Contact Us
an international sales network
airwell HeadqUarter1bis, avenue du 8 Mai 1945
78280 GUYANCOURT FRANCe
Commercial:[email protected]
Aftersales: +33 (0)1 39 44 65 79
Web: www.airwell.com
2 3
table of contents
page
HistorY 4
r&d 6
serviCes 8
CHilled water 12
AQF Fan coil unit 12
KOG 4-way chilled water cassette 14
HAW Hi-wall chilled water unit 16
water Console 18
CAO Water console 18
water Condensing Unit 20
GCAO Water condensing unit 20
split dX 22
FAF Floor ceiling 22
CAF Cassette 600x600 24
CAF Cassette 900x900 26
DAF Ducted 28
DK DN Air to air split system 30
vertiCal CaBinet 34
X AR Vertical air cabinet 34
X AO Vertical water cabinet 36
rooFtop 38
HAN Rooftop unit 38
4 5
indUstrial BeginningsSince the 1950s, ACe has been mass-producing air conditioning systems for private and commercial use. At that time, the company designed the first window unit – one of its flagship products – intended for the european and African markets.
a deCade oF innovationMoving forward, in 1970 Airwell split its “window” unit into two parts to form a “split” system unit, becoming the first european manufacturer to produce this product. Another string was added to its bow a few years later, in 1979, with the air-water heat pump. In the wake of the two oil crises, this system could be connected to existing fuel oil boilers in homes. And in 1982 Airwell came up with the first range of wall split systems, incorporating a remote control, a high-tech tangential flow turbine to reduce noise levels and rotary compressors.
one group, one history,many ambitions
2012 will mark the 65th anniversary of the Group’s activity and international expansion.
The Airwell Group has a long history, marked by innovations at every stage of its development. In 1947 Paul Wallet founded the company L’Air Conditionné Entreprise (ACE) near Paris and, with the brand Airwell, quickly became the leading manufacturer of direct-expansion air conditioners. The foundations had been laid for what would become one of the largest groups worldwide to offer solutions for both the residential sector and to businesses, industry and the service sector.
4 5
ongoing eXpansionAlways at the cutting edge of technology, in 1988 Airwell became the first western company to develop the Inverter system, which varies the speed of the compressor, thus enabling the temperature to be adjusted and energy savings to be made. In the 1990s, the company experienced exceptional growth, resulting in the creation of its “historic” factory in Tillières-sur-Avre, Normandy, and the acquisition of distributors in Spain, Italy, Germany and France.
an international dimensionIn 1997, Airwell joined the Israeli group, elco Holdings, which is listed on the Tel-Aviv stock exchange and is involved in many sectors: household appliances, air conditioning, retail sale of electronics and real estate. Other acquisitions, between 1998 and 2001, most notably of factories in France, Italy and China, strengthened the Group’s international position. At the same time, it expanded its distribution network to Argentina and Turkey. The first decade of the new millennium saw acquisitions in Germany (Polenz Klimatechnik) and the USA (Fedders). Finally, to strengthen its position on the Asian markets, the Airwell Group will open a new factory in Taicang (China) in June 2012.
wHat does tHe FUtUre Hold?Many challenges lie ahead. The first is reliant on increasingly efficient, high quality products and services, which means listening to customers and ensuring a local presence. R&D is also one of the main priorities, with a desire to offer major innovations every year for each business line.
6 7
an eXtensive, diverse range oF solUtionsToday, with a Research & Development (R&D) department with 150 engineers – in France, Italy, China, Hong Kong and Israel – and with a dedicated budget up 40% in 2011, the Airwell Group places a great deal of emphasis on innovation! The result? With more than 600 products designed for all types of installation, we are the only company to offer such a vast range for the residential sector and for business, industry and the service sector. A whole host of full solutions to meet every need: > commercial: applications that lend themselves to the specific nature of each
building;> residential: heating, cooling, dehumidification, air purification;> industrial: water or air condensation units, air treatment units, roof units.
r&d: innovation and performance
To encourage innovation, the Airwell Group has stepped up its R&D activity in the development of technologies designed for maximum comfort, air purification and considerable energy savings.
Innovation is vital to the Airwell Group’s expansion. Having led the field since the 1950s in mass-production of the first window unit, in 1970 it developed a split system unit, becoming the the first European manufacturer of this product, to which new functions have been added over the years: remote control, high-tech tangential flow turbine to reduce noise levels, rotary compressors, etc. And let’s not forget the air-water heat pump that the Group developed in 1979.
6 7
tHe eFFiCienCY oF tHe dC inverterThis approach results in constant product optimisation thanks to the implementation of cutting-edge technologies. The Airwell Group was the first in europe to introduce the DC Inverter in 1988. This system enables compressor speed to be adapted to the desired room temperature through continuous operation that allows the power of the compressor to be adjusted. In this way, as soon as the set temperature is reached the speed is reduced. As well as resulting in energy savings in the region of 30%, this makes the system more versatile and quieter.
tHe sterionizer™ For indoor air treatmentAnother patented technology is changing the future of air conditioning and illustrates the Airwell Group’s desire for innovation. This technology is bipolar ionisation, also known as Sterionizer™. This system generates negative and positive oxygen ions – like those found in nature – causing an electrical chemical reaction that eradicates viruses, bacteria, fungi, mildew, etc. It purifies the air inside the home, neutralises odours and significantly reduces allergies to dust mites. Air as healthy as in the heart of the forest! A whole host of health benefits that have been confirmed by internationally renowned research institutes. The Sterionizer also has the advantage of being compatible with air conditioners, fans, humidifiers and dehumidifiers as well as cooling systems.
CUtting-edge, environmentallY FriendlY teCHnologYSustainable development and respect for the environment are priorities that are incorporated into the manufacturing process across the Airwell range. Pre-empting legislation and energy regulations, the Group offers products that comply fully with european and international standards. Furthermore, the use of advanced technologies helps to reduce the products’ energy consumption and noise levels.
Pre-filters
MULTI LAYERAIR PURIFICATION SYSTEM
Filters coursesdust before entering the unit
OdoursPollenDustBacteria
Smoke
Healthy fresh natural air
Nano Photocatalyst +Antibacterial/ElectrostaticEliminates dust, smoke, odour and bacteria
Super plasmaEliminates remainingbacteria + energizes your air to feel well
8 9
training towards eXpertiseFor Airwell, well-trained professional clients mean successful installations! They are given regular training in order to furnish them with the technical expertise they need to the select the product most suited to the needs of the end user. For approved Service Centers, training focuses on commissioning as well as maintenance and repair work. Generally speaking, the programmes designed for them are built around the following topics.
installation engineers serviCe Centers
product presentation and selection > Commissioning
technical description > Servicing/Maintenance
product installation and use > Repairs
This training combines theoretical classroom presentations and practical work on teaching benches to recreate “real-life” situations.
efficient services for quality follow-up
To overcome installation and after-sales problems, Airwell has set up high quality services.
Keeping our customers happy and meeting all of their expectations about our products is our TOP priority. With this in mind, Airwell is committed to continuously improving its service to professional customers, a policy broken down into three main areas: training, spare parts and technical support.
8 9
spare parts: optimUm response timesThe supply of original Airwell spare parts is highly significant for the reliability and sustainability of our installations. With this in mind, we set up a european spare parts centre in Tillières-sur-Avre, in the eure département, on the site of one of our French factories. With more than 12,000 different products in stock and highly responsive teams, we can deliver parts within 48 hours of order entry and confirmation (subject to availability and specific weight and size constraints). Parts may be available up to ten years after a product has been discontinued (air-water heat pumps and VRF ranges).
Contact the Spare Parts Department: by telephone or email to your dedicated contact; by fax on +33 (0)2 32 32 50 33; by post at the following address: AIRWeLL France SAS, Spare Parts Department, Route de Verneuil, 27570 Tillières sur Avre.
teCHniCal sUpport to meet anY reqUirementAirwell has a network of more than 150 approved Service Centers throughout France, which receive regular product training. Authorised to commission heat pumps and reversible air conditioners, they can also offer maintenance contracts to end users. A worldwide network of Service Centers is also under development. In addition, between 8.30 am and 12.30 pm and 2 pm and 5.30 pm Monday to Friday, a technical support hotline is manned by a team of Airwell technicians. They can answer questions relating to the installation, commissioning and repair of products sold by Airwell. Call them on +33 (0)1 39 44 65 79.For specific questions requiring more in-depth knowledge, technical consultants can visit the site of an end user to investigate the problem with the installation engineer and the distributor.
10 11
model name page7
2 kw9
2.5 kw12
3.5 kw18
5 kw21
6.2 kw24
6.8 kw30
7.8 kw36
10 kw45
12.5 kw >14 kw
CHil
leD
WAt
eR
FAn Coil Unit AQF 12
4-WAy CHilleD WAteR CASSette KOG 14
Hi-WAll CHilleD WAteR Unit HAW 16
WAt
eR S
oU
RCe
H
eAt
pUM
p WAteR ConSole CAO 18
WAteR SoURCe GCAO 20
Spli
t D
x
FlooR Ceiling FAF 22
CASSette 600x600 CAF 24
CASSette 900x900 CAF 26
DUCteD DAF 28
AiR to AiR Split SySteM DK DN 30
VeR
tiCA
l
CAb
inet
VeRtiCAl AiR CAbinet X AR 34
VeRtiCAl WAteR CAbinet X AO 36
Ro
oFt
op
RooFtop Unit HAN 38
air
wel
l R
An
ge
ligh
t Co
mm
erci
al R
ange
10 11
model name page7
2 kw9
2.5 kw12
3.5 kw18
5 kw21
6.2 kw24
6.8 kw30
7.8 kw36
10 kw45
12.5 kw >14 kw
CHil
leD
WAt
eR
FAn Coil Unit AQF 12
4-WAy CHilleD WAteR CASSette KOG 14
Hi-WAll CHilleD WAteR Unit HAW 16
WAt
eR S
oU
RCe
H
eAt
pUM
p WAteR ConSole CAO 18
WAteR SoURCe GCAO 20
Spli
t D
x
FlooR Ceiling FAF 22
CASSette 600x600 CAF 24
CASSette 900x900 CAF 26
DUCteD DAF 28
AiR to AiR Split SySteM DK DN 30
VeR
tiCA
l
CAb
inet
VeRtiCAl AiR CAbinet X AR 34
VeRtiCAl WAteR CAbinet X AO 36
Ro
oFt
op
RooFtop Unit HAN 38
12
Light Commercial |
13
PRODUCT ADVANTAGES Ease of installation. Harmonious and aesthetic RAL9010 painted cabinet design.
Streamlined design and elaborate finish enabling harmonious integration.
5-speed AC fan. Very low operating acoustical levels. Airflow rate between 140 and 1.400 m3/h. Selection of service side. Coil with hydrophilic “blue” fins for condensate flow improvement.
Main OptiOns 3-row coil for optimized cooling performances. Electrical heater with inserted heating rod. AC motor. Selection of 3 speed. Large choice of control: Electro-mechanic, electronic, on-board or wall-mounted.
3-way ON/OFF valve. G2 filter.
Main accessOries Valve. Control. Auxiliary drain pan. Condensate drain pump. Feet. Grille between feet.
Aqu@FanFan Coil Unit - Cooling and heating
Cooling Capacity: from 1.1 to 9.0 kW
Heating Capacity: from 1.2 to 11.6 kW
Sizes: 7
Versions: 2-Pipes 2-Pipes/2-Wires 4-pipes
Configurations: Vertical console with cabinet Vertical concealed without cabinet Ceiling exposed with cabinet Ceiling concealed without cabinet
AIRWELL SOLUTIONS
Operating limit fOr Standard unit
Minimum water temperature +6°C
Maximum water temperature +90°C
Maximum operating pressure 17 bars
Minimum indoor air temperature (room/intake/around unit) 5°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
12 13
Aqu@FAn technicAl dAtAAQUAFAN II Size 20 30 40 50 60 70 80
Product codes:
2Pipe without valve
Vertical Console AWC 7OG033010 7OG033011 7OG033012 7OG033013 7OG033014 7OG033015 7OG033016Vertical Concealed AWN 7OG033034 7OG033035 7OG033036 7OG033037 7OG033038 7OG033039 7OG033040Horizontal Console AHC 7OG033058 7OG033059 7OG033060 7OG033061 7OG033062 7OG033063 7OG033064
Horizontal Concealed AHN 7OG033082 7OG033083 7OG033084 7OG033085 7OG033086 7OG033087 7OG033088
4Pipe without valve
Vertical Console AWC 7OG033026 7OG033027 7OG033028 7OG033029 7OG033030 7OG033031 7OG033032Vertical Concealed AWN 7OG033050 7OG033051 7OG033052 7OG033053 7OG033054 7OG033055 7OG033056Horizontal Console AHC 7OG033074 7OG033075 7OG033076 7OG033077 7OG033078 7OG033079 7OG033080
Horizontal Concealed AHN 7OG033098 7OG033099 7OG033100 7OG033101 7OG033102 7OG033103 7OG033104
2Pipe/2Wire without valve
Electrical heater W 600 600 1000 1200 1500 1500 1800Vertical Console AWC 7OG033018 7OG033019 7OG033020 7OG033021 7OG033022 7OG033023
Vertical Concealed AWN 7OG033042 7OG033043 7OG033044 7OG033045 7OG033046 7OG033047Horizontal Console AHC 7OG033066 7OG033067 7OG033068 7OG033069 7OG033070 7OG033071
Horizontal Concealed AHN 7OG033090 7OG033091 7OG033092 7OG033093 7OG033094 7OG0330952Pipe with 3-w valve
+ Aqu@net + RCL + feet Vertical Console AWC 7OG033113 7OG033114 7OG033115
2Pipe/2Wire with 3-w valve + Aqu@net + RCL + feet
Electrical heater W 600 600 1000Vertical Console AWC 7OG033116 7OG033117 7OG033118
CAPACITIES - 2-PIPE
COOLING (1)
Total cooling capacity W 1870 2440 3460 4220 5730 7210 9040Sensible capacity W 1480 1940 2730 2980 3850 5640 6890Water flow l/h 321 418 594 725 983 1243 1548Water pressure drop kPa 8 16 33 29 42 25 39
HeATING (2) Heating capacity W 2530 3400 4570 5410 7360 9180 11300CAPACITIES - 4-PIPE
COOLING (1)
Total cooling capacity W 1970 2390 3400 4220 5610 7120 8830Sensible capacity W 1520 1880 2660 3000 3770 5540 6710Water flow l/h 338 411 583 724 961 1228 1516Water pressure drop kPa 42 15 31 20 40 24 38
HeATING (3)
Heating capacity W 2320 3340 4540 5250 6060 6980 11600Water flow l/h 204 292 398 460 531 611 1014Water pressure drop kPa 6 13 25 50 15 24 48
SOUND LEVELS (LS/MS/HS)Sound power level dB(A) 34/43/53 37/48/56 37/42/52 37/45/55 43/52/61 46/54/65 49/56/66
CONSOLeSound pressure level (4) dB(A) 26/35/45 29/40/48 29/34/44 29/37/47 35/44/53 38/46/57 41/48/58NR (4) dB(A) 22/31/41 24/36/44 24/29/39 23/33/43 31/39/48 34/41/52 36/44/54
CONCeALeDSound pressure level (5) dB(A) <15/24/32 16/27/35 16/21/31 16/24/34 22/31/40 27/35/44 28/35/45NR (5) dB(A) <15/19/28 <15/23/31 <15/16/26 <15/20/30 18/26/35 23/30/39 23/31/41
FANS (LS/MS/HS)Number 1 1 2 2 2 2 3Airflow m³/h 132/223/317 181/290/407 295/385/570 333/471/736 468/650/917 545/799/1150 665/934/1376
ELECTRICAL (LS/MS/HS)Power supply V/Ph/Hz 230/1/50Fan consumption W 16/27/45 24/40/60 33/39/57 39/45/66 41/64/107 92/110/150 90/112/188Electrical heater (max) W 900 1200 2000 2400 3000 3000 3600
WATER CONNECTIONSType 1/2” Gas Female Threaded
DIMENSIONS Console (LxWxH) mm 768x478x231 953x478x231 1138x478x231 1323x478x231 1508x478x231 1323x578x231 1508x578x231Concealed (LxWxH) mm 510x430x220 695x430x220 880x430x220 1065x430x220 1250x430x220 1065x530x220 1250x530x220
WEIGHTConsole kg 20 23 30 35 39 42 50Concealed kg 14 16 23 27 30 34 41
ACCESSORIES CODE
VALVE 4V/TOR/2T + DRAIN PANVertical AWC/AWN 7ACFH0561 7ACFH0585Horizontal AHC/AHN 7ACFH0562 7ACFH0586
VALVE 4V/TOR/4T + DRAIN PANVertical AWC/AWN 7ACFH0564 7ACFH0588Horizontal AHC/AHN 7ACFH0565 7ACFH0589
AUX DRAIN PANVertical AWC/AWN 7ACTL0394Horizontal AHC/AHN (Left) 7ACTL0446 7ACTL0448
PRC DRAIN PUMP Vertical AWC/AWN 7ACFH0603
FEET - MPCabinet AWC/AHC 7ACTL0391Concealed AWN / AHN 7ACTL0415
GRILL MPG Cabinet AWC/AHC 7ACVF0330 7ACVF0331 7ACVF0332 7ACVF0333 7ACVF0334 7ACVF0333 7ACVF0334TRM-FA 7ACEL1440TRM-VP 7ACEL1443
Aqu@net 7ACEL1432AQUASIMP + WPT Wall-mounted 7ACEL1546 + 7ACEL1547KIT TAE 20 + SHE 7ACEL1452
(1) According to Eurovent standard: Air: 27°C DB/19°C WB , Water: 7°C/12°C.(2) According to Eurovent standard: Air: 20°C, Water : 50°C, same water flow as in cooling.(3) According to Eurovent standard: Air: 20°C, Water: 70°C/60°C.(4) Sound pressure for console unit considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.(5) Sound pressure for concealed unit considering an hypothetical installation and local attenuation of 21 dB(A).
14
Light Commercial |
15
PRODUCT ADVANTAGES Designed for suspended ceiling integration. 600x600 (9, 12 and 18 models) and 600x1200 formats (30 and 45 models).
Low built-in height: 287 mm. Direct access to electrical connection on sliding chassis.
Integrated valve and electrical connections. 5-speed AC fan motor. Very low operating acoustical levels with new low noise LN versions (9, 12 and 18 models).
Fresh air supplied. Air distribution in adjacent room. Integrated condensate drain lift pump up to 600 mm. Infra-red remote control version with valve and change-over.
Galvanized steel sheet with thermal and acoustical insulation, avoiding condensation on the casing and providing good sound attenuation.
Possibility to close one or two discharge flaps. Cleanable synthetic-type air filter. Coil with hydrophilic “blue” fins for condensate flow improvement.
Main OptiOns Electrical heater with inserted heating rod. AC motor. Selection of 3 speed. Aqu@net control or terminal block for wall-mounted thermostat.
2-way or 3-way ON/OFF valve. G1 filter.
Main accessOries Valve. Aqu@net control. Wall-mounted thermostat. Solid ceiling frame. Auxiliary condensate drain pan. Master and slaves control, up to 4 units max.
KOG4-Way Chilled Water Cassette Cooling and heating
Cooling Capacity: from 1.6 to 10.2 kW
Heating Capacity: from 1.8 to 11.6 kW
Sizes: 5
Versions: 2-Pipes 2-Pipes/2-Wires 4-pipes
Configuration: Cassette
Operating limit fOr Standard unit
Minimum water temperature +3°C
Maximum water temperature +70°C (size 09-12-18)/ +60°C (size 30/45)
Maximum operating pressure 15 bars
Minimum indoor air temperature (room/intake/around unit) 13°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
AIRWELL SOLUTIONS
14 15
KOG technical dataKOG Size 09 LN 12 LN 18 LN 30 45
2Pipe without valveCode
K 9 OG 2T SV7OG052008
K 12 OG 2T SV7OG052012
K 18 OG 2T SV7OG052016
K 30 OG 2T SV7SP041036
K 45 OG 2T SV7SP041037
2Pipe with 3-w valveCode
K 9 OG 2T AV7OG052009
K 12 OG 2T AV7OG052013
K 18 OG 2T AV7OG052017
2Pipe with 2-w valveCode
K 9 OG 2T AV2V7OG052350
K 12 OG 2T AV2V7OG052351
K 18 OG 2T AV2V7OG052352
2Pipe/2Wire with 3-w valveCode
K 9 OG 2T CH AV7OG052011
K 12 OG 2T CH AV7OG052015
K 18 OG 2T CH AV7OG052019
2Pipe IR with 3-w valveCode
K 9 OG 2T IR AV7OG102025
K 12 OG 2T IR AV7OG102026
K 18 OG 2T IR AV7OG102027
K 30 OG 2T IR AV7OG101028
K 45 OG 2T IR AV7OG101029
4Pipe without valveCode
K 9 OG 4T SV7OG052020
K 12 OG 4T SV7OG052022
K 18 OG 4T SV7OG052024
K 45 OG 4T SV7SP041024
4Pipe with 3-w valveCode
K 9 OG 4T AV7OG052021
K 12 OG 4T AV7OG052023
K 18 OG 4T AV7OG052025
CAPACITIES - 2-PIPE Nominal
COOLING (1)
Total cooling capacity W 2300 3500 4600 6440 10190
Sensible capacity W 1800 3000 3850 4830 7750
Water flow l/h 400 600 790 1208 1753
Water pressure drop kPa 12 18 16 17 23,5
HeATING (2) Heating capacity W 3100 4500 5700 8050 11600
CAPACITIES - 4-PIPE Nominal
COOLING (1)
Total cooling capacity W 2300 3500 4600 - 10100
Sensible capacity W 1800 3000 3850 - 7254
Water flow l/h 400 600 790 - 1737
Water pressure drop kPa 12 18 16 - 27
HeATING (3)
Heating capacity W 2200 3335 4470 - 6670
Water flow l/h 210 287 380 - 758
Water pressure drop kPa 5 13 28 - 27
SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 34/40/50 34/40/50 35/41/49/57 47/50/57 47/53/59
Sound pressure level (4) dB(A) 26/32/42 26/32/42 27/33/41/49 39/42/49 39/45/51
NR (4) dB(A) 20/27/37 20/27/37 23/28/35/43 34/37/44 34/40/45
FANS (LS/MS/HS)
Number 1 1 1 2 2
Airflow m³/h 330/450/720 330/450/720 290/410/580/830 1100/1350/1550 1000/1250/1630
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption W 20/30/50 20/30/50 21/30/46/71 165/180/200 151/170/180
Electrical heater W 1500 1800 2400 NA NA
WATER CONNECTIONS
Type Gas male threaded
Cooling coil inches 1/2" 1/2" 3/4" 1" 1"
Heating coil inches 1/2" 1/2" 1/2" NA 1/2"
DIMENSIONS
Casing (LxWxH) mm 571x571x287 1171x571x287
Grille (LxWxH) mm 625x625x40 1225x625x40
WEIGHT
Unit weight kg 26 28 29 49 55
ACCESSORIES CODE
TRM-VP 7ACEL1443
TRM-FA 7ACEL1440
Aqu@net 7ACEL1432
AQUASIMP + WPT (Wall-mounted) 7ACEL1546 + 7ACEL1547
TAE20+SEH 7ACEL1452
Relay kit 7ACEL1207
with 3-w valve + condensate tray - 2P - - - 7ACFH0051 7ACFH0052
with 3-w valve + condensate tray - 4P - - - 7ACFH0122
Drain Pan - 2P 7ACTL0083 7ACTL0005 7ACTL0005
Drain pan - 4P 7ACTL0083 - 7ACTL0040
Special frame for solid ceiling 7ACVF0091 - -
(1) According to Eurovent standard: Air: 27°C DB/19°C WB , Water: 7°C/12°C.(2) According to Eurovent standard: Air: 20°C, Water : 50°C, same water flow as in cooling.(3) Air: 20°C, Water: 60°C/50°C.(4) Sound pressure considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.
16
Light Commercial |
17
PRODUCT ADVANTAGES Aesthetic design suitable for home and hotel applications.
Silent unit for optimum customer comfort. Version with Integrated 3-way valve and IR control. Choice between IR or wall-mounted thermostat. Light unit for easy installation. Very easy servicing through removable front plate. Cleanable synthetic-type air filter. Indoor unit compatible with all Airwell chilled water production units.
Main OptiOns RC-08A IR control. Terminal block for wall-mounted thermostat. Version with 3-way ON/OFF valve. 3-speed tangential fan motor. Electro-static anti-bacteria filter. Pipe connectors. Drilling template.
Main accessOries Valve. Aqu@net control. Wall-mounted thermostat.
H@Wairhi-Wall Chilled Water Unit Cooling and heating
Cooling Capacity: from 1.6 to 4.7 kW
Heating Capacity: from 2.1 to 5.9 kW
Sizes: 4
Version: 2-Pipes
Configuration: hi Wall
Operating limit fOr Standard unit
Minimum water temperature +5°C
Maximum water temperature +60°C
Maximum operating pressure 15 bars
Minimum indoor air temperature (room/intake/around unit) 6°C/15% RH
Maximum indoor air temperature (room/intake/around unit) 32°C/70% RH
16 17
H@Wair tecHnical data
AIRWELL SOLUTIONS
H@Wair Size HAW007 HAW009 HWA018 HAW022
2Pipe IR Without valveCode
H@Wair 7 IR SVAWFC-HAW007-A
H@Wair 9 IR SVAWFC-HAW009-A
H@Wair 18 IR SVAWFC-HAW018-A
H@Wair 22 IR SVAWFC-HAW022-A
2Pipe IR With valveCode
H@Wair 9 IR AVAWFC-HAW009-B
H@Wair 22 IR AVAWFC-HAW022-B
2Pipe Without valveCode
H@Wair 7 TB SVAWFC-HAW007-C
H@Wair 9 TB SVAWFC-HAW009-C
H@Wair 18 TB SVAWFC-HAW018-C
H@Wair 22 TB SVAWFC-HAW022-C
CAPACITIES Nominal
COOLING (1)
Total cooling capacity W 2200 2900 3600 4700
Sensible capacity W 1870 2400 3000 3700
Water flow l/h 400 500 620 810
Water pressure drop kPa 10 16 35 50
HeATING (2) Heating capacity W 2900 3700 4800 5850
SOUND LEVELS (LS/MS/HS)
Sound power level dB(A) 36/40/44 38/42/48 45/48/52 50/54/58
Sound pressure level (3) dB(A) 28/32/36 30/34/40 37/40/44 42/46/50
NR (3) dB(A) 23/27/31 25/29/35 32/35/39 37/41/45
FANS (LS/MS/HS)
Number 1 1 1 1
Airflow m³/h 320/380/450 400/500/600 550/650/750 650/750/900
ELECTRICAL (LS/MS/HS)
Power supply V/Ph/Hz 230/1/50
Fan consumption W 22/26/28 22/26/28 25/28/31 43/47/58
WATER CONNECTIONS
Type Gas female threaded
Coil inches 1/2" 1/2" 1/2" 1/2"
DIMENSIONS
Casing (LxWxH) mm 845x275x180 940x298x200
WEIGHT
Unit weight kg 11 11 13 13
(1) According to Eurovent standard: Air: 27°C DB/19°C WB , Water: 7°C/12°C.(2) According to Eurovent standard: Air: 20°C, Water : 50°C, same water flow as in cooling.(3) Sound pressure considering a local of 100 m3, a reverberation time of 0,5 sec and a distance of 1 m.
18
Light Commercial |
19
CAOWater Console - Cooling only
Cooling Capacity: from 2.3 to 4.7 kW
Refrigerant: r-407C
Sizes: 3
Configuration: Monobloc system
PRODUCT ADVANTAGES Ideal solution for premises where it is impossible to install an outdoor unit.
Easy installation and maintenance. Public or recycled water operation. Modulating regulation valve for reducing water consumption.
Possibility of Fresh air supplied. Rotary compressor. Reusable air filters.
Main accessories Remote control. Electric heater.
Operating limit fOr Standard unit
Minimum air temperature 15°C DB/ 10°C WB
Maximum air temperature 32°C DB/ 23°C WB
Minimum water temperature (wasted/recycled) +10°C / 20°C
Maximum water temperature (wasted/recycled) +30°C / 44°C
18 19
CAO teChniCAl dAtA
CAO 230 CAO 370 CAO 580
Code 7CW011016 7CW011017 7CW011018
CAPACITIES
COOLING
Cooling capacity kW 2.3 3.0 4.7
Power input kW 0.66 0.85 1.30
EER 3.4 3.5 3.6
VENTILATION
Airflow range (min/max) m³/h 450/550 450/550 725/880
Fresh Airflow m³/h 60 60 80
HYDRAULIC
Water flow l/h 130 170 270
SOUND LEVELS
Sound pressure level (4m) (min/max) dB(A) 37/40 38/41 41/43
POWER SUPPLY
Power supply 230/1P/50 Hz
DIMENSIONS
LxWxH mm 1030x226x620 1030x226x620 1390x226x620
WEIGHT
Unit weight kg 48 49 69
ACCESSORIES
Electric heaterkW 2 2 3
Code 7ACEL0006 7ACEL0006 7ACEL0007
Remote control Code 7ACEL0039 7ACEL0039 7ACEL0039
AIRWELL SOLUTIONS
20
Light Commercial |
21
PRODUCT ADVANTAGES Water flow protection by pressostat valve. High pressure switch with manual reset. Super quiet. Connection to HHF 9-12-18-24 indoor units. Ideal solution for premises where it is impossible to install an outdoor unit.
Connection to recycled or lost water systems. Water intake and drainage via public water network. Pressostat valve supplied (to limit water consumption). High Pressure safety pressostat valve with manual reset. Low sound emission value.
GCAOWater Condensing Unit
Water condensing unit with capacities from 2.7 to 6.4 kW.
Cooling only. sizes: 4. refrigerant: r410a.
Main OptiOns High efficiency and energy saving product. R410A fluid. Oxidize and degrade organic contaminants. It can effectively eliminate 99.9% of bacteria and collect dust effectively.
Remove in high efficient small particles from the air and purify the air from bacteria.
Avoid bacteria and mildew growing by keeping the heat exchanger dry after cooling operation.
Precise temperature control around dedicated area by using remote control temperature sensor.
Better cooling and heating affect by extending the air distribution in the room in a wide angle.
Improve cooling and heating affect by swing the air up and down automatically.
Adjusting the room temperature along the night follow human sleep behaviour.
Boosting the output capacity and create a rapid reaction to reach the room temperature set up.
Option to set up the stop and operation. Indication to replace the remote control battery. Automatic restart the unit in the last operation mode once resume power supply.
Lock the remote control function to avoid non required operation.
Slim and small size to reduce the unit space required and provide esthetic image.
Super Plasma.
20 21
GCAO teChniCAl dAtA
Outdoor units GCAO 9N GCAO 12N GCAO 18N GCAO 24N
COOLING Capacity kW 2.7 3.4 5.57 6.37
Input power kW 0.73 1.03 1.39 1.93
EER/Energy Label 3.70/A 3.30/B 4.01/A 3.30/B
Operating limits indoor temperature °C 17°/32° Dry Bulb
Condenser inlet water temperature °C 10°/45°
OUTDOOR UNIT
Sound power level to 1 m dB(A) 49 49 51 53
Waste water flow at + 15°C l/h 120 160 250 320
Recycled water flow 30/35°C l/h 600 850 1 250 1 550
Compressor type Rotary Rotary Rotary Rotary
Dimensions (WxDxH) mm 625x360x473 625x360x473 625x360x473 625x360x473
Weight kg 41 45 50 56
Part number 7SP101040 7SP101041 7SP101045 7SP101044
POWER SUPPLY
1~230V - 50 Hz
Power supply side Outdoor Outdoor Outdoor Outdoor
Power cable section mm2 3x1.5 3x1.5 3x1.5 3x2.5
Fuse rating am A 10 10 10 16
Electrical connections mm2 3x1.5 3x1.5 3x1.5 4x2.5
PIPE LINE Suction pipe diameter inches 3/8” 3/8” 1/2” 5/8”
Liquid pipe diameter inches 1/4” 1/4” 1/4” 3/8”
Max length m 25 25 25 25
Max height m 15 15 15 15
Indoor units € AWSI-HHF009-N11 AWSI-HHF012-N11 AWSI-HHF018-N11 AWSI-HHF024-N11
COOLING Capacity kW 2.64 3.22 5.3 6.15
INDOOR UNIT
Sound pressure level to 1 m (LS/MS/HS/SS) dB(A) 32/35/37/40 32/35/38/41 35/39/42/45 38/41/44/47
Sound power level(LS/MS/HS/SS) dB(A) 42/45/47/50 42/45/48/51 45/49/52/55 48/51/54/57
Dehumidification l/h 0.8 1.2 1.8 3
Airflow (LS/MS/HS/SS) m3/h 310/340/370/400 350/420/500/550 550/650/780/850 550/650/780/850
Dimensions (WxDxH) mm 730x174x255 790x177x265 940x200x298 940x200x298
Weight kg 8 9 13 13
Part number 7SP022856 7SP022857 7SP022858 7SP022859
AIRWELL SOLUTIONS
22
Light Commercial |
23
PRODUCT ADVANTAGES Wired and wireless remote controls provided as standard.
Self diagnostic (error indications) in remote the wired remote control for ease of maintenance.
Centralized controller up to 16 units including weekly timer (optional).
FAFFloor Ceiling
Floor and ceiling line available in capacities from 3.5 to 12 kW.
Cooling & heating operation mode. Precise temperature control around dedicated area by using remote control temperature sensor.
available in 3Ph from 10 kW.
RC08A
RCW4 (optional)
RCW3
ACCESSORIES/OPTIONSAcc. Reference Photo Description Additional
accessory required Function
RCW-4 7ACEL1613
Wired Option to control a several units with one main controller.
- Control up to 16 indoor unit as a group or individualy. - Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing. - Indicating failure code.
Main OptiOns R410A fluid. Avoid bacteria and mildew growing by keeping the heat exchanger dry after cooling operation.
Precise temperature control around dedicated area by using remote control temperature sensor.
Better cooling and heating affect by extending the air distribution in the room in a wide angle.
Improve cooling and heating affect by swing the air up and down automatically.
Adjusting the room temperature along the night follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air during start operating in heating.
Digital display on the indoor unit, indicating the temperature set up or failure code.
Boosting the output capacity and create a rapid reaction to reach the room temperature set up.
Option to set up the stop and operation. Indicate the digital failure code on the unit display for easy detecting and solve problems.
Indication to replace the remote control battery. Automatic restart the unit in the last operation mode once resume power supply.
Lock the remote control function to avoid non required operation.
Minimize the operation without supplying energy during defrost in heating.
Automatically switch the operation between cooling to heating to maintain the room set temperature.
Option to control a several units with one main controller.
22 23
FAF technicAl dAtA
AIRWELL SOLUTIONS
Indoor Units AWSI-FAF012-N11 AWSI-FAF018-N11 AWSI-FAF024-N11 AWSI-FAF030-N11 AWSI-FAF036-N11 AWSI-FAF042-N11
Outdoor Units 1~230V - 50 Hz AWAU-YIF012-H11 AWAU-YIF018-H11 AWAU-YIF024-H11 AWAU-YIF030-H11 AWAU-YIF036-H11
Outdoor Units 3~400V - 50 Hz AWAU-YIF036-H13 AWAU-YIF042-H13
COOLING Capacity kW 3.50 5.00 7.00 8.80 10.00 12.00
Input power kW 1.17 2.03 2.61 3.00 3.60 4.80
EER/Energy Label 2.99 2.46 2.68 2.93 2.77 2.5
Outdoor temperature operating limits °C 18°/43° Dry bulb
HEATING Capacity kW 3.60 5.70 8.00 9.80 11.00 14.00
Input power kW 1.10 2.07 2.59 2.85 3.3 4.7
COP/Energy Label 3.27 2.75 3.08 3.43 3.33 2.97
Outdoor temperature operating limits °C -7°/24° Dry bulb
INDOOR Sound pressure level to 1 m (LS/MS/HS)
dB(A) 41/44/46 46/50/54 46/48/50 49/51/52 48/51/54 48/51/54
Sound power level (LS/MS/HS) m3/h 51/54/56 56/60/64 56/58/60 59/61/62 58/61/64 58/61/64
Airflow (LS/MS/HS) m3/h 550/670/790 970/970/1070 1000/1080/1170 1300/1450/1600 1520/1630/1800 1520/1630/1800
Dehumidification l/h 1.2 1.9 2.4 2.3 2.9 4.3
Dimensions (WxDxH) mm 836x695x238 836x695x238 1300x600x188 1420x700x245 1590x695x238 1590x695x238
Weight kg 27 27 32 50 42 42
Part number 7SP012196 7SP012197 7SP012184 7SP012185 7SP012186 7SP012187
OUTDOOR Sound pressure level to 1 m dB(A) 56 56 59 59 60 60
Sound power level dB(A) 66 66 69 69 70 70
Airflow m3/h 2800 2800 3200 4200 4000 6000
Compressor type Rotary Rotary Rotary Rotary Scroll Scroll
Dimensions (WxDxH) mm 848x320x540 848x320x540 1018x412x700 980x427x790 1018x412x840 950x412x1250
Weight kg 32 40 59 70 90 112
1~230V - 50 Hz Part number 7SP061779 7SP061780 7SP061781 7SP061782 7SP061783
3~400V - 50 Hz Part number 7SP061784 7SP061785
POWER SUPPLY
1~230V - 50 Hz
Power supply side Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor
Power cable section mm2 3x1.0 - 3x1.5 3x1.0 - 3x2.5 3x1.0 - 3x4.0 3x1.0 - 3x6.0 3x1.0 - 3x6.0
Fuse rating am A 6 -16 6 - 20 6 - 25 6 - 32 6 - 40
Electrical connections mm2 2x0.75 2x0.75 2x0.75 2x0.75 2x0.75
POWER SUPPLY
3~400V - 50 Hz
Power supply side Indoor & Outdoor Indoor & Outdoor
Power cable section mm2 3x1.0 - 5x2.5 3x1.0 - 5x2.5
Fuse rating am A 6 - 16 6 - 20
Electrical connections mm2 2x0.75 2x0.75
PIPE LINE Suction pipe diameter inches 1/2” 1/2” 5/8" 5/8" 3/4" 3/4"
Liquid pipe diameter inches 1/4” 1/4” 3/8" 3/8" 1/2" 1/2"
Max length m 20 20 30 30 50 50
Max height m 15 15 15 15 30 30
24
Light Commercial |
25
PRODUCT ADVANTAGES Wired and wireless remote controls provided as standard.
Self diagnostic (error indications) for ease of maintenance.
230 mm height only. Centralized controller up to 16 units including weekly timer (optional).
Fresh air supplied.
CAFCassette 600x600
Cassette line available in capacities from 3.5 to 5.0 kW.
Cooling & heating operation mode. Precise temperature control around dedicated area by using remote control temperature sensor.
RC08ARCW4
(optional)RCW3
ACCESSORIES/OPTIONSAcc. Reference Photo Description Additional
accessory required Function
RCW-4 7ACEL1613
Wired Option to control a several units with one main controller.
- Control up to 16 indoor unit as a group or individualy. - Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing. - Indicating failure code.
Main OptiOns R410A fluid. Avoid bacteria and mildew growing by keeping the heat exchanger dry after cooling operation.
Precise temperature control around dedicated area by using remote control temperature sensor.
Better cooling and heating affect by extending the air distribution in the room in a wide angle.
Excellent cooling and heating affect by swing the air up and down, left and right automatically.
Adjusting the room temperature along the night follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air during start operating in heating.
Digital display on the indoor unit, indicating the temperature set up or failure code.
Boosting the output capacity and create a rapid reaction to reach the room temperature set up.
Option to set up the stop and operation. Indicate the digital failure code on the unit display for easy detecting and solve problems.
Indication to replace the remote control battery. Automatic restart the unit in the last operation mode once resume power supply.
Lock the remote control function to avoid non required operation.
Minimize the operation without supplying energy during defrost in heating.
Automatically switch the operation between cooling to heating to maintain the room set temperature.
Condensate drain pump. Option to control a several units with one main controller.
24 25
CAF teChniCAl dAtA
Indoor Units AWSI-CAF012-N11 AWSI-CAF018-N11
Outdoor Units AWAU-YIF012-H11 AWAU-YIF018-H11
COOLING Capacity kW 3.50 5.00
Input power kW 1.17 2.00
EER/Energy Label 2.99 2.50
Outdoor temperature operating limits °C 18°/ 43° Dry bulb
HEATING Capacity kW 3.60 5.70
Input power kW 1.10 1.90
COP/Energy Label 3.27 3.00
Outdoor temperature operating limits °C -7°/ 24° Dry bulb
INDOOR UNIT
Sound pressure level to 1 m dB(A) 43/45/47 43/45/47
Sound power level dB(A) 53/55/57 53/55/57
Airflow m3/h 620/720/820 620/720/820
Dehumidification l/h 1.1 1.9
Dimensions (WxDxH) mm 600x600x230 600x600x230
Weight kg 20 20
Frame Dimensions 650x650 mm 650x650x50 650x650x50
Weight kg 2.5 2.5
Part number 7SP042208 7SP042209
Part number Frame 650x650 7ACVF0547 7ACVF0547
OUTDOOR UNIT
Sound pressure level to 1 m dB(A) 56 56
Sound power level dB(A) 66 66
Airflow m3/h 2800 2800
Compressor type Rotary Rotary
Dimensions (WxDxH) mm 848x320x540 848x320x540
Weight kg 40 40
Part number 7SP061779 7SP061780
POWER SUPPLY
1~230V - 50 Hz
Power supply side Indoor & Outdoor Indoor & Outdoor
Power cable section mm2 3x1.0 - 3x1.5 3x1.0 - 3x2.5
Fuse rating am A 6 -16 6 - 20
Electrical connections mm2 2x0.75 2x0.75
PIPE LINE Suction pipe diameter inches 1/2” 1/2”
Liquid pipe diameter inches 1/4” 1/4”
Max length m 20 20
Max height m 15 15
AIRWELL SOLUTIONS
26
Light Commercial |
27
PRODUCT ADVANTAGES Wired and wireless remote controls provided as standard.
Self diagnostic (error indications) for ease of maintenance.
230 mm height only. Centralized controller up to 16 units including weekly timer (optional).
Fresh air supplied.
CAFCassette 900x900
Cassette line available in capacities from 6.8 to 12 kW.
Cooling & heating operation mode. Precise temperature control around dedicated area by using remote control temperature sensor.
available in 3Ph from 10 kW.
RC08ARCW4
(optional)RCW3
ACCESSORIES/OPTIONSAcc. Reference Photo Description Additional
accessory required Function
RCW-4 7ACEL1613
Wired Option to control a several units with one main controller.
- Control up to 16 indoor unit as a group or individualy. - Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing. - Indicating failure code.
Main OptiOns R410A fluid. Avoid bacteria and mildew growing by keeping the heat exchanger dry after cooling operation.
Precise temperature control around dedicated area by using remote control temperature sensor.
Better cooling and heating affect by extending the air distribution in the room in a wide angle.
Excellent cooling and heating affect by swing the air up and down, left and right automatically.
Adjusting the room temperature along the night follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air during start operating in heating.
Digital display on the indoor unit, indicating the temperature set up or failure code.
Boosting the output capacity and create a rapid reaction to reach the room temperature set up.
Option to set up the stop and operation. Indicate the digital failure code on the unit display for easy detecting and solve problems.
Indication to replace the remote control battery. Automatic restart the unit in the last operation mode once resume power supply.
Lock the remote control function to avoid non required operation.
Minimize the operation without supplying energy during defrost in heating.
Automatically switch the operation between cooling to heating to maintain the room set temperature.
Condensate drain pump. Option to control a several units with one main controller.
26 27
CAF teChniCAl dAtA
Indoor Units AWSI-CAF024-N11 AWSI-CAF030-N11 AWSI-CAF036-N11 AWSI-CAF042-N11
Outdoor Units 1~230V - 50 Hz AWAU-YIF024-H11 AWAU-YIF030-H11 AWAU-YIF036-H11
Outdoor Units 3~400V - 50 Hz AWAU-YIF036-H13 AWAU-YIF042-H13
COOLING Capacity kW 6.80 8.30 10.00 12.00
Input power kW 2.62 2.90 3.60 4.80
EER/Energy Label 2.59 2.86 2.77 2.50
Outdoor temperature operating limits °C 18°/43° Dry bulb
HEATING Capacity kW 7.50 8.80 11.00 14.00
Input power kW 2.50 3.15 3.30 5.00
COP/Energy Label 3.00 2.79 3.33 2.80
Outdoor temperature operating limits °C -7°/24° Dry bulb
INDOOR UNIT
Sound pressure level to 1 m dB(A) 43/45/47 48/49/51 48/51/53 48/51/53
Sound power level dB(A) 53/55/57 58/59/61 58/61/63 58/61/63
Airflow m3/h 1000/1080/1180 1170/1270/1400 1500/1570/1660 1500/1570/1650
Dehumidification l/h 2.35 2.7 2.9 4.3
Dimensions (WxDxH) mm 840x840x260 840x840x260 840x840x320 840x840x320
Weight kg 30 27 38 38
Frame Dimensions 950x950 mm 950x950x60 950x950x60 950x950x60 950x950x60
Weight kg 6.5 6.5 6.5 6.5
Part number 7SP042210 7SP042211 7SP042212 7SP042213
Part number Frame 950x950 7ACVF0548 7ACVF0548 7ACVF0548 7ACVF0548
OUTDOOR UNIT
Sound pressure level to 1 m dB(A) 59 59 60 60
Sound power level dB(A) 69 69 70 70
Airflow m3/h 3200 4200 4000 6000
Compressor type Rotary Rotary Rotary Scroll
Dimensions (WxDxH) mm 1018x412x700 980x427x790 1018x412x840 950x412x1250
Weight kg 59 70 90 112
1~230V - 50 Hz Part number 7SP061781 7SP061782 7SP061783
3~400V - 50 Hz Part number 7SP061784 7SP061785
POWER SUPPLY
1~230V - 50 Hz
Power supply side Indoor & Outdoor Indoor & Outdoor Indoor & Outdoor
Power cable section mm2 3x1.0 - 3x4.0 3x1.0 - 3x6.0 3x1.0 - 3x6.0
Fuse rating am A 6 - 25 6 - 32 6 - 40
Electrical connections mm2 2x0.75 2x0.75 2x0.75
POWER SUPPLY
3~400V - 50 Hz
Power supply side Indoor & Outdoor Indoor & Outdoor
Power cable section mm2 3x1.0 - 5x2.5 3x1.0 - 5x2.5
Fuse rating am A 6 - 16 6 - 20
Electrical connections mm2 2x0.75 2x0.75
PIPE LINE Suction pipe diameter inches 5/8" 5/8” 3/4” 3/4”
Liquid pipe diameter inches 3/8" 3/8” 1/2” 1/2”
Max length m 30 30 50 50
Max height m 15 15 30 30
AIRWELL SOLUTIONS
28
Light Commercial |
29
PRODUCT ADVANTAGES Wired and wireless remote controls provided as standard.
Self diagnostic (error indications) in remote the wired remote control for ease of maintenance.
Space saving due to low unit height. Centralized controller up to 16 units including weekly timer (optional).
DAFdUCted
ducted line available in capacities from 20 up to 39.5 kW.
Cooling & heating operation mode. Precise temperature control around dedicated area by using remote control temperature sensor.
ACCESSORIES/OPTIONSAcc. Reference Photo Description Additional
accessory required Function
RCW-4 7ACEL1613
Wired Option to control a several units with one main controller.
- Control up to 16 indoor unit as a group or individualy. - Option to set in each indoor unit ON/OFF, set temperature, timer (daily and
weekly), mode, fan speed and swing. - Indicating failure code.
RC08ARCW4
(optional)RCW3
Main OptiOns R410A fluid. Avoid bacteria and mildew growing by keeping the heat exchanger dry after cooling operation.
Precise temperature control around dedicated area by using remote control temperature sensor.
Improve cooling and heating affect by swing the air up and down automatically.
Adjusting the room temperature along the night follow human sleep behaviour.
Control the fan operation to avoid drafting of cold air during start operating in heating.
Boosting the output capacity and create a rapid reaction to reach the room temperature set up.
Option to set up the stop and operation. Indicate the digital failure code on the unit display for easy detecting and solve problems.
Indication to replace the remote control battery. Automatic restart the unit in the last operation mode once resume power supply.
Lock the remote control function to avoid non required operation.
Minimize the operation without supplying energy during defrost in heating.
Automatically switch the operation between cooling to heating to maintain the room set temperature.
Option to control a several units with one main controller.
28 29
AIRWELL SOLUTIONS
DAF technicAl DAtA
Indoor Units DAF068 DAF085 DAF102 DAF136
Outdoor Units 3~400V-50 Hz YIF68T YIF85T YIF102T YIF136T
COOLING Capacity kW 20 24.5 30 39.5
Input power kW 8.4 9.8 11 15.8
EER/Energy Label 2.5/E 2.5/E 2.4/F 2.5/E
Annual energy consumption kW/h 4200 4900 5500 7900
HEATING Capacity kW 22 27.5 33 42
Input power kW 7 9 9 14
COP/Energy Label 3.1/D 3.05/D 3.14/D 3/D
INDOOR UNIT
Sound pressure level to 1m dB(A) 56 54 57 58
Rated current (CO/HP) A 15.3/13.2 19.2/17.7 20.7/18 30/26.6
Fan motor speed rpm 1380 1007 1390 961
External static pressure Pa 200 (100-250) 110 (30-250) 200 (100-250) 150 (50-300)
Airflow m3/h 4000 4800 5500 7000
Dimensions (WxHxD) mm 1150x460x1350 1150x460x1600 990x880x1772 1290x880x1772
Weight kg 86 150 156 215
Code 7SP032127 7SP032128 7SP032129 7SP032130
OUTDOOR UNIT
Sound pressure level to 1m dB(A) 65 66 67 69
Airflow m3/h 8000 8000 11000 13000
Dimensions (WxHxD) mm 1463x799x389 1500x1000x500 1500x1000x500 1700x1100x650
Weight kg 158 185 216 285
Code 7SP061794 7SP061795 7SP061796 7SP061797
PIPE LINE Length of free charge g/m 7.5 7.5 7.5 7.5
Gas additional charge g/m 110 54 110 170
Max tubing length m 50 50 50 50
Max height difference m 30 30 30 30
30
Light Commercial |
31
PRODUCT ADVANTAGES Weather resistant casing with external panels coated with powder-based epoxy paint colour RAL 9001.
Indoor centrifugal fan units for duct network connection.
High static pressure available. Multi-position architecture for horizontal or vertical mounting (acc. to models).
Compact, top discharge outdoor fan units. Low noise axial fan. Scroll compressor with crankcase heater. Electrical, refrigeration and thermal protection devices.
Phase controller. External HP and LP pressure taps. Frame and air filter supplied.
DK DNair to air sPlit systeM - Cooling and heating Mode
Cooling Capacity: from 12 to 83 kW
Heating Capacity: from 12.4 to 83.8 kW
Refrigerant: r407C
Sizes: 12
Configuration: Packaged split system
AIRWELL SOLUTIONS
Main OptiOns Factory-fitted low ambient temperature control to ensure cooling operation down to -10°C outdoor temperature (All-season).
Main accessOries Synthetic air filter. Electric heater. Programmable controller RCW2 to control up to 15 units with independent set points and programming.
Operating limit fOr Standard unitCOOLING MODE
Minimum indoor air temperature 21°C DB/ 15°C WB
Maximum indoor air temperature 32°C DB/ 23°C WB
Minimum outdoor air temperature / with all-season kit 15°C DB/ -10°C
Maximum outdoor air temperature 46°C DB
HEATING MODE
Maximum indoor air temperature 27°C DB
Minimum outdoor air temperature -10°C
Maximum outdoor air temperature 24°C DB / 18°C WB
30 31
DK DN 125-155-185 techNical Data
INDOOR UNIT DK 125 DK-V 125 DK 155 DK-V 155 DK 185
OUTDOOR UNITCool only DN 125 DN 125 DN 155 DN 155 DN 185
Reversible DN 125RC DN 125RC DN 155RC DN 155RC DN 185RC
Product codes:
Indoor UnitSmall ventilation Code 7SP051153 7SP051152 7SP051154 7SP051151 7SP051069
High ventilation Code - - - - -
Outdoor Unit - Cool only
standard Code 7SP111061 7SP111061 7SP111054 7SP111054 7SP111055
With all-season control Code 7SP111081 7SP111081 7SP111082 7SP111082 7SP111080
Outdoor Unit - Reversible
standard Code 7SP111062 7SP111062 7SP111056 7SP111056 7SP111057
With all-season control Code 7SP111079 7SP111079 7SP111083 7SP111083 7SP111084
CAPACITIES
COOLING
Cooling capacity kW 12.0 12.0 14.5 14.5 17.5
Power input kW 4.9 4.9 5.8 5.8 6.9
EER 2.4 2.4 2.5 2.5 2.5
HeATING
Heating capacity kW 12.4 12.4 15.7 15.7 18
Power input kW 4.8 4.8 5.8 5.8 6.4
COP 2.6 2.7 2.7 2.8 2.7
INDOOR UNIT
VeNTILATION
Available static pressure Pa 160 180 130 110 200
Nominal Airflow m³/h 2100 2100 2850 2850 3500
Airflow range (min/max) m³/h 1600/2400 1600/2400 2300/3100 2300/3100 2800/3900
SOUND LeVeLS Sound power level dB(A) 72 69 73 72 75
DIMeNSIONS LxWxH mm 1150x745x340 1050x972x350 1350x745x340 1254x972x350 1350x745x400
Mounting H/V H H/V H H/V H
WeIGHT Unit weight kg 58 69 65 77 98
OUTDOOR UNIT
VeNTILATIONNumber of fan 1 1 1 1 1
Nominal Airflow m³/h 5400 5400 9000 9000 9000
SOUND LeVeLS Sound power level dB(A) 82 82 82 82 79
DIMeNSIONS LxWxH mm 746x746x 909 746x746x 909 900x800x1060 900x800x1060 900x800x1060
WeIGHT Unit weight kg 140 140 150 150 164
POWER SUPPLY Power supply 400V/3P/50 Hz
Power supply side Outdoor
PIPE LINE Suction pipe diameter < 20m inches 3/4" 3/4" 7/8" 7/8" 7/8"
Suction pipe diameter > 20m inches 3/4" 3/4" 3/4" 3/4" 3/4"
Liquid pipe diameter < 20m inches 1/2" 1/2" 1/2" 1/2" 5/8"
Liquid pipe diameter > 20m inches 1/2" 1/2" 1/2" 1/2" 5/8"
Max lenght m 50 50 50 50 50
Max height m 50 50 50 50 50
ACCESSORIES
Electric heater
kW 6 9 6 10.5 12
Code 7ACEL1093 7ACEL1208 7ACEL1096 7ACEL1209 7ACEL1184
kW 8.1 - 8.1 - -
Code 7ACEL1094 7ACEL1097
Remote control RCW2 Code 7ACEL1212
Air filter Code 7ACVF0077 7ACVF0077 7ACVF0078 7ACVF0078 -
32
Light Commercial |
33
DK DN 205-255-305-405 techNical Data
INDOOR UNIT DK 205 DK 255 DK 305 DK 405 M DK 405
OUTDOOR UNITCool only DN 205 DN 255 DN 305 DN 405 M DN 405
Reversible DN 205RC DN 255RC DN 305RC DN 405MRC DN 405RC
Product codes:
Indoor UnitSmall ventilation Code 7SP051141 7SP051142 7SP051143 7SP051155 7SP051144
High ventilation Code - - 7SP051147 7SP051156 7SP051148
Outdoor Unit - Cool only
standard Code 7SP112013 7SP112014 7SP112015 7SP112131 7SP112016
With all-season control Code 7SP112082 7SP112083 7SP112084 7SP112131 7SP112085
Outdoor Unit - Reversible
standard Code 7SP112019 7SP112020 7SP112021 7SP112132 7SP112022
With all-season control Code 7SP112088 7SP112089 7SP112090 Included 7SP112091
CAPACITIES
COOLING
Cooling capacity kW 19.1 21.0 28.5 36.0 37.5
Power input kW 7.3 8.6 11.5 13.9 14.4
EER 2.6 2.4 2.5 2.6 2.6
HeATING
Heating capacity kW 18.3 21 27.3 36.0 36.5
Power input kW 6.7 7 9.3 13.3 11.9
COP 3 2.9 2.7 3 2.9
INDOOR UNIT
VeNTILATION
Available static pressure Pa 210 210 190 180 180
Nominal Airflow m³/h 4500 4680 5760 7560 7560
Airflow range (min/max) m³/h 3600/5000 3800/5100 4600/6300 6000/8200 6000/8200
SOUND LeVeLS Sound power level dB(A) 84 84 78 83 83
DIMeNSIONS LxWxH mm 1352x1060x400 1692x1060x400 1690x1005x676 1690x1005x676 1690x1078x676
Mounting H/V H H H H H
WeIGHT Unit weight kg 98 100 150 160 160
OUTDOOR UNIT
VeNTILATIONNumber of fan 1 1 1 1 1
Nominal Airflow m³/h 9000 9000 9000 16000 2x9000
SOUND LeVeLS Sound power level dB(A) 78 78 86 83 87
DIMeNSIONS LxWxH mm 900x800x1060 900x800x1060 1003xx1003x1094 1004x1004x1257 1708x1123x972
WeIGHT Unit weight kg 164 164 187 247 317
POWER SUPPLY Power supply 400V/3P/50 Hz
Power supply side Outdoor
PIPE LINE Suction pipe diameter < 20m in 1-1/8" 1-1/8" 7/8" 1-3/8" 7/8"
Suction pipe diameter > 20m in 1-1/8" 1-1/8" 1-1/8" 1-3/8" 7/8"
Liquid pipe diameter < 20m in 1/2" 1/2" 5/8" 5/8" 1/2"
Liquid pipe diameter > 20m in 5/8" 5/8" 5/8" 5/8" 5/8"
Max lenght m 30 30 30 30 30
Max height m 15 15 15 10 15
ACCESSORIES
Electric heater
kW 12 18 18 21 21
Code 7ACEL1186 7ACEL1189 7ACEL1176 7ACEL1177 7ACEL1177
kW - - - - -
Code
Remote control RCW2 Code 7ACEL1212
Air filter Code 7ACVF0124 7ACVF0124 7ACVF0125 7ACVF0125 7ACVF0125
32 33
DK DN 505-605-755-905 techNical Data
INDOOR UNIT DK 505 DK 605 DK 755 DK 905
OUTDOOR UNITCool only DN 505 DN 605 DN 755 DN 905
Reversible DN 5RC05RC DN 605RC DN 75RC5RC DN 905RC
Product codes:
Indoor UnitSmall ventilation Code 7SP051145 7SP051146 7SP051122 7SP051123
High ventilation Code 7SP051149 7SP051150 - -
Outdoor Unit - Cool only
standard Code 7SP112017 7SP112018 7SP112137 7SP112146
With all-season control Code 7SP112086 7SP112087 Included Included
Outdoor Unit - Reversible
standard Code 7SP112023 7SP112024 7SP112138 7SP112147
With all-season control Code 7SP112092 7SP112093 Included Included
CAPACITIES
COOLING
Cooling capacity kW 44.0 56.0 69.1 83.0
Power input kW 16.7 22.5 26.9 33.0
EER 2.6 2.5 2.6 2.5
HeATING
Heating capacity kW 42.0 57.5 71.0 83.8
Power input kW 14.4 22.9 26.4 32.4
COP 2.5 2.7 2.6 2.5
INDOOR UNIT
VeNTILATION
Available static pressure Pa 520 320 330 460
Nominal Airflow m³/h 9360 9720 12000 14300
Airflow range (min/max) m³/h 7500 / 10300 7780 / 11000 9600 / 13200 11440 / 15730
SOUND LeVeLS Sound power level dB(A) 84 85 87 87
DIMeNSIONS LxWxH mm 2100x1078x703 2100x1078x703 2208x949x795 2208x949x945
Mounting H/V H H H H
WeIGHT Unit weight kg 205 209 266 282
OUTDOOR UNIT
VeNTILATIONNumber of fan 2 2 2 2
Nominal Airflow m³/h 2x9000 2x9000 2x16000 2x16000
SOUND LeVeLS Sound power level dB(A) 86 86 87 87
DIMeNSIONS LxWxH mm 1708x1123x1171 1708x1123x1171 2213x1345x1309 2213x1345x1459
WeIGHT Unit weight kg 378 405 559 592
POWER SUPPLY Power supply 400V/3P/50 Hz
Power supply side Outdoor
PIPE LINE Suction pipe diameter < 20m in 7/8" 1-1/8" 1-1/8" 1-3/8"
Suction pipe diameter > 20m in 7/8" 1-1/8" 1-3/8" 1-3/8"
Liquid pipe diameter < 20m in 1/2" 1/2" 5/8" 5/8"
Liquid pipe diameter > 20m in 5/8" 5/8" 5/8" 5/8"
Max lenght m 30 30 30 30
Max height m 15 15 15 15
ACCESSORIES
Electric heater
kW 30 30 30 30
Code 7ACEL1178 7ACEL1178 7ACEL1340 7ACEL1340
kW - - - -
Code - - - -
Remote control RCW2 Code 7ACEL1212
Air filter Code 7ACVF0126 7ACVF0126 - -
34
Light Commercial |
35
X ARVertiCal air Cabinet - Cooling only
Cooling Capacity: from 9.7 to 55 kW
Refrigerant: r407C
Sizes: 6
Configuration: split system
PRODUCT ADVANTAGES Easy installation and maintenance. Split system with outdoor condenser fan unit. Treated air distribution to premise by plenum or duct network.
Adjustable available static pressure. Temperature control by thermostat. Electrical, refrigeration and thermal protection devices.
Main accessories Room thermostat. Electric heater. Hot water heating coil. “All season” system (Cooling mode operation down to outdoor temperature of -10°C).
Remote fault reporting. Plenum. Duct flange. Valves. Pipe link.
Operating limit fOr Standard unitINDOOR UNIT
Minimum air temperature (room / intake / around unit) 21°C DB/ 15°C WB
Maximum air temperature (room / intake / around unit) 32°C DB/ 23°C WB
OUTDOOR UNIT
Minimum air temperature / with all-season kit 15°C DB/ -10°C
Maximum air temperature 46°C DB
34 35
AIRWELL SOLUTIONS
X AR technicAl dAtA
INDOOR UNIT X 1100 AR X 1900 AR X 2450 AR X 3250 AR X 4650 AR X 6450 AROUTDOOR UNIT UC 33 A UC 53 A UC 73 A UC 103 A UC 73 A UC103 AProduct codes:
Indoor unit Code 7XU022082 7XU022077 7XU022078 7XU022079 7XU022080 7XU022081
Outdoor unit Code 7XU031025 7XU031026 7XU031027 7XU031028 2 x 7XU031027 2 x 7XU031028
COOLING CAPACITIES
Cooling capacity kW 9.7 16.2 19.8 29.0 38.9 55.0
Power input kW 4.6 6.8 8.9 12.6 16.9 24.0
EER 2.13 2.38 2.22 2.3 2.3 2.3
Cooling circuit 1 1 1 1 2 2
INDOOR UNIT
VeNTILATION
Available static pressure Pa 200 300 200 200 250 290
Nominal Airflow m³/h 2000 3200 4500 5800 9000 12000
Airflow range (min/max) m³/h 1500/2500 2500/3800 3600/5400 4600/7000 7200/10800 9500/14500
SOUND LeVeLS Sound power level dB(A) 66 68 75 81 77 85
DIMeNSIONSLxWxH mm 890x430x1540 1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970 1980x790x1970
Plenum height mm 220 260 350 350 400 400
WeIGHT Unit weight kg 136 182 265 350 525 600
OUTDOOR UNITCondenser unit 1 1 1 1 2 2
VeNTILATION Nominal Airflow m³/h 220 260 350 350 400 400
SOUND LeVeLS Sound power level dB(A) 54 58 61 73 64 76
DIMeNSIONS LxWxH mm 885x825x831 885x825x831 1141x885x831 1546x885x893 1141x885x831 1546x885x893
WeIGHT Unit weight kg 59 68 93 130 93 130
POWER SUPPLY
Power supply 400V/3P/50 Hz
Power supply side Indoor
PIPE LINE Suction pipe diameter in 1/2" 1/2" 5/8" 3/4" 5/8" 3/4"
Liquid pipe diameter in 3/8" 3/8" 1/2" 5/8" 1/2" 5/8"
Max lenght m 45 45 45 45 45 45
ACCESSORIES
Set of female valves Code 7ACFH0054 7ACFH0055 7ACFH0056 7ACFH0061 7ACFH0057 7ACFH0060
Pipe link Code 7ACFH0210 7ACFH0211 7ACFH0212 7ACFH0213 7ACFH0214 7ACFH0215
Electric heaterkW 9 12 18 22.5 37.5 45
Code 7ACEL0042 7ACEL0043 7ACEL0057 7ACEL0058 7ACEL0116 7ACEL0119
Hot water coil kW 15.5 29.7 38.5 50 77 94
Code 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180 7ACFH0170
ON/OFF switch and room thermostat Code 7ACEL0041 7ACEL0041 7ACEL0032 7ACEL0032 7ACEL0032 7ACEL0032
"High ventilation" Code 7ACVF0023 7ACVF0024 - - - -
"All season" system Code 7ACFH0069 7ACFH0070 7ACFH0104 7ACFH0072 7ACFH0071 7ACFH0146
Remote fault reporting Code 7ACEL0072 7ACEL0072 7ACEL0071 7ACEL0071
Air distribution duct frame Code 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052 7ACVF0052
Total rear air intake duct frame Code 7ACVF0041 7ACVF0104 7ACVF0043 7ACVF0044 7ACVF0045 7ACVF0046
Front air distribution plenum Code 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110 7ACVF0111
Fresh air supplied Code 7ACVF0047 7ACVF0047 - - - -
36
Light Commercial |
37
X AOVertiCal Water Cabinet - Cooling only
Cooling Capacity: from 8 to 45.7 kW
Refrigerant: r407C
Sizes: 6
Configuration: Monobloc system
Operating limit fOr Standard unit
Minimum air temperature 21°C DB/ 15°C WB
Maximum air temperature 32°C DB/ 23°C WB
Minimum water temperature +10°C
Maximum water temperature +30°C
PRODUCT ADVANTAGES Easy installation and maintenance. Monobloc system. Public or recycled water operation. Treated air distribution to premise by plenum or duct network.
Adjustable available static pressure. Temperature control by thermostat. Electrical, refrigeration and thermal protection devices.
Main accessories Room thermostat. Electric heater. Hot water heating coil. Remote fault reporting. Plenum. Duct flange.
36 37
AIRWELL SOLUTIONS
X AO technicAl dAtA
X AO Model CX 25 X 1100 AO X 1900 AO X 2450 AO X 3250 AO X 4650 AO
Product codes:
230V/1P/50 Hz Code 7XU012032 - - - - -
400V/3P/50 Hzwith valve Code 7XU012033 7XU012025 7XU012028 7XU012029 7XU012030 7XU012031
without valve Code - - - 7XU012047 7XU012048 7XU012064
CAPACITIES
COOLING
Cooling capacity kW 8.0 11.7 18.0 23.0 32.4 45.7
Power input kW 2.6 3.8 5.8 7.1 9.8 13.9
EER 3.14 3.08 3.1 3.24 3.31 3.29
Cooling circuit 1 1 1 1 1 2
VENTILATIONAvailable static pressure Pa 80 200 250 200 250 250
Nominal Airflow m³/h 1500 2000 3200 4500 5800 9000
Airflow range (min/max) m³/h 1160/1750 1500/2500 2500/3800 3600/5400 4600/7000 7200/10800
HYDRAULIC
WASTeD WATeRWater flow m3/h 0.34 0.58 0.92 1.45 2 2.8
pressure drop kPa 20 22 18 42 40 18
ReCYCLeD WATeR
Water flow m3/h 1.17 2.1 3.4 4.3 5.8 8.3
pressure drop kPa 21 50 70 60 40 56
SOUND LEVELSSound power level dB(A) 64 65 67 74 80 76
POWER SUPPLY
Power supply 230V/1P/50 Hz400V/3P/50 Hz 400V/3P/50 Hz
DIMENSIONS
LxWxH mm 800x407x 1280 890x430x1540 1000x500x1735 1300x600x1840 1530x600x1840 1715x790x1970
Plenum height mm 300 220 260 350 350 400
WEIGHTUnit weight kg 125 151 199 305 380 565
ACCESSORIESElectric heater kW 5.49 9 12 18 22.5 37.5
230V/1P/50 Hz code 7ACEL0017 - - - - -
400V/3P/50 Hz Code 7ACEL0018 7ACEL0042 7ACEL0043 7ACEL0057 7ACEL0058 7ACEL0116
Hot water coil kW - 15.5 29.7 38.5 50 77
Code - 7ACFH0062 7ACFH0063 7ACFH0064 7ACFH0118 7ACFH0180
ON/OFF switch and room thermostat Code 7ACEL0030 7ACEL0041 7ACEL0041 7ACEL0032 7ACEL0032 7ACEL0032
"High ventilation" Code 7ACVF0025 7ACVF0023 7ACVF0024 - - -
Sum heating resistance Code 7ACVF0027 7ACVF0029 included - - -
Remote fault reporting Code 7ACEL0072 7ACEL0072 7ACEL0071
Air distribution duct frame Code - 7ACVF0101 7ACVF0102 7ACVF0050 7ACVF0051 7ACVF0052
Total rear air intake duct frame Code - 7ACVF0041 7ACVF0104 - - -
Front air distribution plenum Code 7ACVF0112 7ACVF0105 7ACVF0106 7ACVF0108 7ACVF0109 7ACVF0110
Fresh air supplied Code - 7ACVF0047 7ACVF0047 - - -
38
Light Commercial |
39
HANrooFtoP Unit - Cooling and heating
Cooling Capacity: from 9.8 to 31kW
Heating Capacity: from 9.6 to 30.5 kW
Refrigerant: r410a
Sizes: 7
Configuration: Compact monobloc system
PRODUCT ADVANTAGES Weather resistant casing with external panels and drain pan coated with powder-based epoxy paint colour RAL 9001.
Base rail with forklift slots to facilitate transportation and handling.
Technical compartment independent from airstreams allowing service works to be performed without disturbing the unit operation.
High EER and environmentally friendly refrigerant R410A with zero ODP (Ozone Depleting Potential).
High efficiency scroll compressor with crankcase heater.
Condenser coils with hydrophilic coated fins to improve removal of water droplets during defrost cycles.
Standard microprocessor-based control by CAC controller.
Main OptiOns Factory-fitted low ambient temperature control to ensure cooling operation down to -10°C outdoor temperature (All-season).
Main accessOries Synthetic air filter. Electric heater. Programmable controller RCW2 to control up to 15 units with independent set points and programming.
Operating limit fOr Standard unitCOOLING MODE
Minimum indoor air temperature 21°C DB/ 15°C WB
Maximum indoor air temperature 32°C DB/ 23°C WB
Minimum outdoor air temperature / with all-season kit 15°C DB/ -10°C
Maximum outdoor air temperature 50°C DB
HEATING MODE
Maximum indoor air temperature 27°C DB
Minimum outdoor air temperature -10°C
Maximum outdoor air temperature 24°C (16°C for HAN 25)
38 39
AIRWELL SOLUTIONS
HAN tecHNicAl dAtA
HAN Model HAN 10 HAN 13 HAN 15 HAN 17 HAN 19 HAN 25 HAN 31
Product codes:
standard Code 7HL023001 7HL023002 7HL023003 7HL023004 7HL023005 7HL023006 7HL023007
with all season control Code 7HL023008 7HL023009 7HL023010 7HL023011 7HL023012 7HL023013 7HL023014
CAPACITIES
COOLING
Cooling capacity kW 9.8 13.0 14.5 16.8 18.9 25.4 31.0
Power input kW 3.7 4.5 4.9 6.0 6.5 8.3 10.0
EER 2.64 2.88 2.95 2.8 2.9 2.95 3.1
HeATING
Heating capacity kW 9.6 12.1 14.2 15.8 19.0 24.2 30.5
Power input kW 3.0 4.3 4.5 5.7 6.0 8.8 9.5
COP 3.2 2.8 3.1 2.7 3.1 2.75 3.2
VENTILATION
Available static pressure Pa 90 100 170 160 210 240 250
AIRFLOWIndoor fan m³/h 1930 2640 2940 3190 3860 4780 5530
Outdoor fan m³/h 5200 9000 9000 9000 9000 12000 12000
SOUND LEVELS
Sound power level (Indoor) dB(A) 79.7 79.3 79.3 79.3 83.1 84.9 86.4
Sound power level (Outdoor) dB(A) 76.1 75.0 75.0 75.0 72.7 78.2 82.7
POWER SUPPLY
Power supply 400V/3P/50 Hz
DIMENSIONS
LxWxH mm 1115x1150x750 1320x1345x905 1320x1345x905 1320x1345x905 1320x1345x905 1420x1445x1320 1420x1445x1320
WEIGHT
Unit weight kg 165 219 223 223 243 320 343
ACCESSORIES
Air filter Code 7ACVF0145 7ACVF0481 7ACVF0481 7ACVF0481 7ACVF0481 7ACVF0482 7ACVF0482
Electric heaterkW 6 9 9 12 12 12 12
Code 7ACEL1216 7ACEL1217 7ACEL1217 7ACEL1219 7ACEL1219 7ACEL1219 7ACEL1219
Remote control RCW2 Code 7ACEL1212 7ACEL1212 7ACEL1212 7ACEL1212 7ACEL1212 7ACEL1212 7ACEL1212
Airwell France SAS1 bis avenue du 8 mai 194578280 GuyancourtFranceTel. +33 (0)1 39 44 78 00Fax +33 (0)1 39 44 00 14www.airwell.com
LCA
C E
XP
GB
041
2 -
Sp
ecifi
catio
ns s
ubje
ct t
o ch
ange
with
out
notic
e. P
ictu
res
non
cont
ract
ual.
Prin
ted
in U
E.