ALARM APPLICATIONS
DS200 Alarm Interface is an infrastructre, which provides a platform to program DS200 system via one central point or collect the alarm
Basically, DS200 Alarm Interface consist of a central DS200 system and a PC on which the applications will be run
ALARM APPLICATIONS
System Requirements:
- DS200 Alarm Card- DS200 Alarm Supply (AL04)- Alarm Panel- Power Supply (220V)
ALARM APPLICATIONS
DS200 Alarm Card:– It is a card with 4 channel outputs and 28
channel inputs which is using the serial communication slot of the system instead of the PCM channels
– The card has 8 RJ45 connectors directly on board● The 1st one is used to output some alarm signals
to a specific alarm panel. The rest is used to input different alarm signals from 28 different sources (especially for Rural applications)
ALARM APPLICATIONS
The four alarm outputs on a PABX system
are used for:1. PABX is fed by the battery2. PRI connection was broken3. Redundant CPU is in service4. A card is powered OFF
The outlook of the alarm panel,
which is used to visualize these alarm signals
STOPPING ALARM
● This program allows stopping the alarm signal onEX200(Alarm) Alarm Module.
800701 P
ParametersP: 1,2,3,4 The number of the LED on Alarm Module
Notes:The alarm on the top LED of the module can be stopped bydialing 1, whereas the alarm on the bottom LED can bestopped by dialing 4.
ALARM APPLICATIONS
DS200 Alarm Panel:
- It required a feed of 12 VDC. In order to provide the 12 VDC feed, a power module which is called AL04 is available to convert the 48 VDC output of the system to 12 VDC
ALARM APPLICATIONS
Cabling:
- In order to make the cabling of alarm card through the 8 RJ45 connectors on the card, pieces of CBL-16 MDF Cable is used
- The first 4 channels of the alarm card is used to drive an alarm panel fed by a 12 VDC supply
- The input of this power module is taken from the battery connector of the system
ALARM APPLICATIONS
- There are also four alarm channels to carry the outputs of the alarm card to the alarm panel
- The inputs and outputs are carried in parallel
The illustration of the cabling of the power module
ALARM APPLICATIONS
Application:- After cabling of Alarm Card, Alarm Panel, Battery
and Alarm Supply, insert the Alarm Card into a slot of DS system
- Make sure that the order of cabling is correct for the connection of the cable mentioned in the Installation guide
Please see the pairs in the 2 CBL-16 cables and the corresponding alarm channels that are presented in the Installation guide
ALARM TABLE
- After all, you can manage alarm signals from IDEAaccording to the alarm types– This menu offers a facility that can be activated only
through IDEA ,and it is used to activate alarm on certain functions.
This line is used to activate Alarm Panel
ALARM TABLE
The following alarm functions can be programmed:● Extension Fail: The error when an extension has left his telephone off hook.
● PRI Synchronization Error: The error when there is a failure on PRIsynchronization.● Card Error (General): The error when a card has been powered off.● Card Error (EVM) / Card Error (SS7): Reserved for future use.
● Analog Trunk Error / E&M Trunk Error / E&M PLC Error: The error whenthe lines are out of service or there is no dial tone on the lines.
● Rural Extension Test Error: The error when there is failure in EX200 (0/16R)tests.● Main Power Supply Error: The error when there is 220 V mains failure.● CPU Card Error: The error when the system is working on the redundant CPU
ALARM TABLE
The following media can be programmed for showing alarm:
► FT Alarm: The LCD of FT20 connected to the first extension of the system.
► CM Alarm: INFO file that is a sub-file of Net-CM program.
► LOG Alarm: DS200.LOG file of IDEA .
► Alarm Lamp: The Alarm Module of the system. Within this option, the
LED on which alarm will be displayed, can also be selected.
► Relay Alarm: The relay(s) on CPUKON card. Within this option, the relay
number can also be selected (for DS200 systems).
► KTS Alarm: The LEDs of fast dial keys on FT20 / LT200 (-H) and DSS
modules.These LEDs start blinking when the assigned ports are problematic
(like dial tone failure, or synchronization lost, etc…)