Alarma Contraincendio Siemens

Embed Size (px)

Citation preview

  • 8/13/2019 Alarma Contraincendio Siemens

    1/28

    1

    BC80 system catalog.

    Building Technologies

  • 8/13/2019 Alarma Contraincendio Siemens

    2/28

    A wide range of applications.BC80 comprises an extensive product portfolio andcan be installed in various building types. For instance,it is a perfect solution for:

    Hotels Commercial buildings Residential complexes

    Government buildings Retail stores

    2

  • 8/13/2019 Alarma Contraincendio Siemens

    3/28

    3

    High quality based on decadesof experience, in-depth research,and state-of-the-art productiontechnology from Siemens

    A flexible solution expandable and compatiblewith future developments

    Cost-effective moderateinvestment and easy adaptationto changing requirements

    BC80 advantages at a glance:

    Siemens quality high reliability

    With the BC80 system, you can offeryour customers Siemens quality,based on in-depth research and de-velopment, state-of-the-art produc-tion technology and over 150 yearsof experience in fire protection. Theproducts meet all technical safetyrequirements, from short-circuit pro-tection to immunity against electro-magnetic interference.

    BC80 offers the flexibility your cus-tomers need, whether they want toexpand or modernize their system.Thanks to its open topology, the sys-tem is forward-looking for easyadaptation to growth and changingrequirements.

    Siemens technology high cost-effectiveness

    BC80 combines high-quality tech-nology with cost-effectiveness, inprocurement as well as operation.Moderate hardware costs keep theinvestment manageable, while theflexible, expandable installation pro-tects the long-term view genuinebrand quality at an economical price,for years to come.

    High-quality Siemensproducts reliable and

    economical. Your customers are responsible for the protec-tion of their employees, buildings, and assets.They also experience cost competition. As aresult, they need fire protection componentsthat deliver reliable fire detection and alarmsignaling, but which are also cost-efficient. Firesafety products from Siemens position you per-fectly to satisfy your customers requirements.

    The BC80 system products range from fire detec-tors to control panels. They are moderatelypriced and of reliable quality.

  • 8/13/2019 Alarma Contraincendio Siemens

    4/28

    4

    Easy installation fast protection

    Because the BC80 system units havebeen designed for easy installation,buildings can be protected quickly.BC80 provides polarity-free wiring;poles can no longer be accidentallyreversed. Therefore, the networkingof BC80 fire detectors, peripheralequipment, and BC80 control panelsis rapid and accurate. The use of spurlines and T-Branches (F-Bus) furthersimplifies installation.

    Easy configuration fast commissioning

    Commissioning of the BC80 systemis supported by an integrated auto-configuration function; with it, thesystem automatically detects all inte-grated devices (auto-mapping). Thisreduces manual configuration to aminimum eliminating a potentialsource of error. You benefit from ashorter time to a fully-operationalsystem.

    More complex manual programmingcan be conducted via the controlpanels or by using Windows-basedsoftware.

    Easy concepts makeyour work easier.

    BC80 fire protection products are easy to imple-ment and service. They can be quickly installedand rapidly commissioned. This reduces yourcosts and speeds up order processing. Simplicityof design reduces the period needed to gainfamiliarity with the system, so you can offeryour customers user-friendly fire protection inthe shortest possible time.

    Easy maintenance no interruption of operation

    All devices displayed on the con-trollers are shown with both theiraddress number and position details.These help your customers assesserror messages as aids to decision-making, and you to keep a clearoverview during installation andmaintenance. Devices with conven-tional technology, such as collectivefire detectors, can also be wired tothe BC80 system via spur lines.

    Tracing faulty fire detectors or periph-eral devices during system operationis swift, targeted, and cost-efficient.

  • 8/13/2019 Alarma Contraincendio Siemens

    5/28

    5

    Easy installation and fast buildingprotection thanks to installationaids and polarity-free non-shieldedcabling

    Fast commissioning thanks toauto-mapping and Windows-basedsoftware

    Minimal maintenance withaddress and position of all detectorsand peripheral devices needingservice directly indicated

    Smooth expansion via card insertsfor control panels and T-Branchesfor cabling

    Easy modernization through useof present cabling, compatibilitywith existing peripheral equipment,and simple software uploads

    BC80 advantages at a glance:

    Easy expandability high flexibility

    BC80 grows with your customersrequirements. When buildings orrooms are extended, the BC80 in-stallation can also be expanded, forexample with new T-Branches in thecabling and expansion cards in thecontrol panels.

    With an expansion card it is possibleto hook up an additional 127 periph-eral devices via the F-Bus, as many as32 additional control panels via theA-Bus, and up to three B-Bus devices,such as extinguishing control panelsor interlocking panels. This increasesoptions for larger projects.

    Easy conversion fast modernization

    Existing systems can be replaced andmodernized with BC80 without largecabling expenditures. Currently in-stalled cables can be used to networkBC80 devices, since neither the firedetector lines nor the notificationappliance circuits require a shieldedwire. The system can also be linkedwith existing peripheral devices,which saves time and money. Soft-ware updates can be uploaded viathe USB port of the control panels.

  • 8/13/2019 Alarma Contraincendio Siemens

    6/28

    6

    BC80 design andinstallation guidelines.

    In this section, we illustrate best practice forinstallation of fire detection equipment. Whilenot all possible cases may be covered, these areintended to provide guidelines. Local regulationsmay be more detailed and must always be ob-served. Please contact your local Siemens salesorganization for more detailed information anddocumentation.

    BC80 detectors detectors should bepositioned*

    at least 0.5 m from the wallmax. 12 m from the previousdetector

    BC80 manual call points manual call points shouldbe positioned*

    in a clearly visible location1.5 m from floor level

    BC80 fire control panels mounting the fire controlpanel*Keep a minimum distance toobjects which could obscurethe panel or the view to it

  • 8/13/2019 Alarma Contraincendio Siemens

    7/28

    7

    * or observe local regulations

    Detector positioningnear elevators*

    Detector positioning nearfresh air supply*

    Use a support to install adetector at ceiling height*

  • 8/13/2019 Alarma Contraincendio Siemens

    8/28

    8

    BC80 design andinstallation guidelines.

    * or observe local regulations

    Place the detector at thehighest point in the room*

    Ensure the correct distanceto ceiling obstacles*

    Position the detector withinthe top 10% of a space*

    Ensure a minimum distanceto objects which could ob-struct the view to a manualcall point*

    Manual call points shouldnot be obscured by an opendoor*

  • 8/13/2019 Alarma Contraincendio Siemens

    9/28

    9

    Planning aid for fieldbus.

    BDS031

    BDS051

    BDS121

    BDS132

    BDS221

    BDS152

    BDS161

    BDS331

    Load Max. current (mA)Quiescentcurrent (mA)Name Address points

    0.71

    0.71

    0.43

    0.6

    0.61

    0.07

    4

    10

    0.89

    0.89

    2.86

    3.8

    2.19

    0.5

    16

    90

    1

    1

    1

    1

    2

    0

    10

    1

    Heat detector

    Photoelectric smoke detector

    Manual call point

    Input module

    Output module

    Isolate module

    Collective input module

    Fire alarm display panel

    BC8001

    BC8001E

    BC8001P

    BC8001PE

    BC8002-1

    BC8002-2

    BC8002-3

    Source Max. current (mA)Quiescent

    current (mA)Name Address points

    48.5

    63.3

    51.2

    66.0

    130.0

    170.0

    210.0

    75.7

    113.7

    97.0

    135.6

    224.8

    352.6

    481.4

    127

    254

    127

    254

    500

    1,000

    1,500

    Compact controller with 1 line

    Compact controller with 2 lines

    Compact controllerwith 1 line, printer

    Compact controllerwith 2 lines, printer

    Wall-mounted (500 dev.)

    Wall-mounted (1,000 dev.)

    Wall-mounted (1,500 dev.)

    Detectors and peripherals

    Panels and systems

  • 8/13/2019 Alarma Contraincendio Siemens

    10/28

    A-Bus

    Compact

    Heat detectorBDS031

    Photoelectricsmoke detectorBDS051

    Manualcall pointBDS121/e

    Output moduleBDS221

    Manualcall pointBDS121/e

    Input moduleBDS132

    Collectiveinput moduleBDS161Compact controller

    BC8001

    F-Bus

    Interlocking panelBT8012

    Interlocking panelBT8011

    Compact controllerBC8001

    Collectiveheat detectorHI520

    10

    BC80 at a glance.

  • 8/13/2019 Alarma Contraincendio Siemens

    11/28

    B-BusExtinguishing panelBC8013

    Standard control panelBC8002

    Standard

    F-Bus

    Collectivephotoelectric smokedetector OP520

    Standard control panelBC8002

    11

    LegendA-Bus Network for connecting control panels

    (max. 32 control panels, bus length 1 km can be extended with CAN-Bus bridge)

    F-Bus Bus system for connecting line devices

    (max. 127 devices per line, bus length 1 km)

    B-Bus Network for connecting up to 3 B-Bus devices(bus length 100 m)

  • 8/13/2019 Alarma Contraincendio Siemens

    12/28

    Building Technologies

    BC80 Innovative fire safety productsfrom Siemens.Are you seeking reliable and easy to use fire safety products everywhere? With theaddressable BC80, Siemens offers an extensive and economical portfolio from firedetectors to control panels. Thanks to its open topology, BC80 is highly flexible andadapts easily to changing requirements. The perfect solution for a wide range ofapplications from small to large buildings, it can be quickly installed, networked, andput into service. Backed by 150 years of experience in fire protection, BC80 offersthe effective protection you want for people, buildings and assets.For more information, please visit www.siemens.com/buildingtechnologies.

    Genuine quality foryour protection.

  • 8/13/2019 Alarma Contraincendio Siemens

    13/28

    Table of Contents

    1 Siemens Building Technologies Group

    Panels & Systems ................................................................................................................. 1-1Addressable Control Panels.............................................................................................. 1-1

    Detectors & Peripherals........................................................................................................ 2-5Conventional Detectors and Bases (Collective)........... ............. ............. ............. ............. ... 2-5

    Addressable Detectors and Bases............. ............. .............. ............. ............. ............ ........ 2-6Manual Call Points ............ ............ ............. ............. ............. ............. ............. ............. ..... 2-7Addressable Modules ....................................................................................................... 2-8

    Spare Parts & Upgrades...................................................................................................... 3-10

  • 8/13/2019 Alarma Contraincendio Siemens

    14/28

  • 8/13/2019 Alarma Contraincendio Siemens

    15/28

    Panels & SystemsAddressable Control Panels

    1-1 Siemens Building Technologies Group

    1

    Type Order No.

    BC8001.. BC8001 Compact Control Unit

    BC8001 is a control unit suitable for small sized projects and construc-tions. It has the following features:

    l Compatible to BDS series of field devices.l Features a polarity free F-BUS with a twisted pair of wires

    ( 1.5mm2). Transmission distance is up to 1000m. All devicesshould be evenly distributed.

    l Specialized BDS Algorithm enhance immunity against environmentdisturbances.

    l Menu driven man-machine interface to allow very easy operation.l With optional extension card the device can be networked with up to

    32 other BC80 control units (BC8001/BC8002).l With optional extension card it is possible to connect up to 3 B-Bus

    devices i.e. interlocking and extinguishing panels.l An optional printer can be mounted into the control unit.l The system can be easily configured directly on the panel or via PC.l Configuration data can be uploaded to a PC at any time.

    Number of detector lines 1Number of field devices 127System Network -Built-in printer -LCD Display 240 x 128 BacklitAuto Mapping YesEvent memory 1000Digital inputs/outputs 1 Dry contact (24 VDC / 3 A)

    1 OC output2 Monitored inputs

    Operating voltage (Main Power) 187... 242 VAC

    50... 60 HzBattery capacity 24 VDC 7 AhDownload/Upload USBDimensions (W x H x D) 370 x 265 x 120 mmWeight (without battery) 3.0 kgData sheet A5Q00016399A

    BC8001..

    BC8001 BC8001 Compact Control Unit with 1 F-Bus line for up to127 Devices

    Technical details as BC8001..

    A6C50000016

    BC8001P BC8001P Compact Control Unit with 1F-Bus line and printer

    As BC8001.. for technical details but with the following differences:

    One printer TP8000 (thermal sensitive printer) is built-in.

    A6C50000018

  • 8/13/2019 Alarma Contraincendio Siemens

    16/28

    Panels & SystemsAddressable Control Panels

    1-2 Siemens Building Technologies Group

    Type Order No.

    BC8001E BC8001E Compact Control Unit with 2 F-Bus lines for up to 254Devices

    As BC8001.. for technical details but with the following differences:

    An extension card is built-in additionally in the BC8001. This allows

    l Interconnection of up to 32 BC8001 or BC8002 control units (A-Bus).l Interconnection of up to 3 B-BUS equipments (BT8011/12 interlock-

    ing panel BC8013 extinguishing panel). Another external powersupply (3 A @ 28 VDC) must be used.

    A6C50000017

    BC8001PE BC8001PE Compact Control Unit with 2 F-Bus lines and printer

    As BC8001.. for technical details but with the following differences:

    Printer and extension card are built-in additionally.

    A6C50000019

    BC8002.. BC8002-1/e wall-mounted Advanced Control UnitBC8002 is an advanced control unit based on latest technology to sup-port easy operation and commissioning.

    l Text and graphic Display with 10 LCD,640x320 dots backlit.l Easy operation with a menu structure similar to Windows Explorer.l Advanced micro-processor system (32-bit ARM based micro-proces-

    sor).l LCD display shows real time values of fire parameters for every detec-

    tion point.l Auto mapping of the controller configuration simplifies commission-

    ing.l Multi-tasking real time operating system monitors the system regu-

    larly. This ensures high system reliability.l Up to 1000 events are stored in the event memory.l Modular structure allows flexible system customization.l System configurations can be done via panel keypads or via PC tool

    (parameters and logic expressions).l Powerful interlocking features can be added for demanding control

    functions.l Up to 32 control units can be interconnected via A-Bus network.

    Transmission distance is up to 1000m with a twisted pair of wires( 1.5mm2).

    l BC8002 can be connected to a management station.

    Mains voltage 220 VAC 50 HzOperating voltage 23... 30 VDCBattery capacity 24 VDC 17 AhQuiescent current 40... 100 WFuse 2.0 AOperating temperature -10... +50 CRelative humidity 95% (40 2 C)Dimensions (W x H x D) 700 x 520 x 120 mmWeight 22 kgData sheet A5Q00016408A

    BC8002..

    BC8002-1 BC8002-1/e wall-mounted Advanced Control Unit for up to 500devices 4 loops

    As BC8002.. for technical details but with the following differences:

    The fire alarm control unit with the original 1 line card can connect upto 500 devices.

    A6C50000029

  • 8/13/2019 Alarma Contraincendio Siemens

    17/28

    Panels & SystemsAddressable Control Panels

    1-3 Siemens Building Technologies Group

    1

    Type Order No.

    BC8002-2 BC8002-2 wall-mounted Advanced Control Unit for up to 1000devices

    As BC8002.. for technical details but with the following differences:

    The fire alarm control unit with an additional line card can connect upto 1000 devices using 8 loops

    A6C50000030

    BC8002-3 BC8002-3 wall-mounted Advanced Control Unit forv1500 devices

    As BC8002.. for technical details but with the following differences:

    The fire alarm control unit with 3 line cards can connect up to 1500devices using 12 loops

    A6C50000030

    BT80.. BT8011 / BT8012 Interlocking Panel

    BT8011 / BT8012 are interlocking panels. It allows manual and auto-matic control of external equipment. It is usually installed in the firecontrol center together with fire alarm panels in order to controlpumps fans etc.

    Operating voltage 24... 29 VDCQuiescent current 50 mAOperating temperature 0... +50 CStorage temperature -20... +60 CRelative humidity 95 % RhLoad for each output 300 4 K Installation height 3 UData sheet A5Q00016409A

    BT80..

    BT8011 BT8011 Interlocking Panel

    As BT80.. for technical details but with the following differences:

    l equipped with 16 inputs and 8 outputs.l Inputs: 8 inputs are for general purpose and 8 inputs are for confir-

    mations.l Outputs: OC output capacity is 28 VDC / 80 mA.l Output can be configured as steady on or pulsed.l Device is connected with the control unit via B-Bus.l Indication of activation confirmation and fault for each output .l Silence and lamp test keypad available.l Panel can be set to manual mode or automatic mode.l Panel address output mode connection mode are set with DIP-

    switch.l TP8000 printer is built-in.

    A6C50000032

    BT8012 BT8012 Interlocking Panel (without printer)

    As BT80.. for technical details but with the following differences:

    l Equipped with 16 outputs and 24 inputs.l Inputs: 8 inputs are for general purpose 16 inputs are for confirma-

    tionl Outputs: each OC output capacity is 28 VDC / 80 mA.l Output can be configured as steady on or pulsed.l Device is connected with the control unit via B-Bus.l Indication of activation confirmation and fault for each output.l Silence and lamp test keypad available.l Panel can be set to manual mode or automatic mode.l Panel address output mode connection mode are set with DIP-

    switch.

    A6C50000033

  • 8/13/2019 Alarma Contraincendio Siemens

    18/28

    Panels & SystemsAddressable Control Panels

    1-4 Siemens Building Technologies Group

    Type Order No.

    BC8013.. BC8013 Extinguishing Panel

    The extinguishing panel is used for the control of the extinguishingsections of a fire installation.

    l One panel monitors 2 extinguishing sections.l Each section is equipped with 3 outputs to activate extinguishing

    alert extinguishing section separation and gas release. 3 inputs serveas confirmation of above control outputs.

    l The device is connected via B-Bus. The address is set with a DIP-switch.

    l Important information of the extinguishing section are displayed onthe control unit.

    l Parameters can be configured on the panel directly or via PC-Tool.l External control wires are monitored for short or open circuit.l Panel can be set to automatic mode and manual mode.l Panel supports auto mapping feature .

    Operating voltage 24... 28 VDCQuiescent current 40 mAOperating current 200 m AOutput current 80 m AMaximum current per output 200 m AOperating temperature -20... +40 CData sheet A5Q00016401A

    BC8013..

    BC8013 BC8013 Extinguishing Panel

    Same technical details as BC8013..

    A6C50000038

    BC8013H BC8013H wall-mounted Extinguishing PanelAs BC8013.. for technical details but with the following differences:

    Wall-mounted Extinguishing Panel

    A6C50000022

  • 8/13/2019 Alarma Contraincendio Siemens

    19/28

    Detectors & PeripheralsConventional Detectors and Bases (Collective)

    2-5 Siemens Building Technologies Group

    2

    Type Order No.

    HI520 HI520 Collective Heat Detector (Rate of Rise and Fix Temperature)

    l Newly developed circuit and sensor ensure high performance offixed and rate of rise temperature detection.

    l High stability against dust electromagnetic interference tempera-ture fluctuation humidity and corrosion.

    l Produced with SMT advanced technology.

    Operating voltage 16... 32 VDCOutput voltage 5... 13 VDCOperating temperature -10... +50 CStorage temperature -30... +75 CRelative humidity 95 % (40 2 C)Quiescent current 100 AAlarm current 1.5 mAEMC 10 V/m

    Data sheet A5Q00016379A

    A6C50000009

    OP520 OP520 Collective Optical Smoke Detector

    The OP520 is an non addressable detector which can be connected into S11 and BC80 system via corresponding collective input modules.

    l Patented optical structure and labyrinth.l Homogeneous sensitivity for different kind of smoke.l High stability against dust electromagnetic interference tempera-

    ture fluctuation humidity and corrosion.l Produced with advanced SMT technology.l Connection is independent of line polarity.

    Operating voltage 21... 29 VDCOutput voltage 5... 13 VDCOperating temperature -10... +50 CStorage temperature -30... +75 CRelative humidity 95 % (40 2 C)Quiescent current 100 AAlarm current 1.5 mAEMC 10 V/mData sheet A5Q00016380A

    A6C50000010

    SO520 SO520 Collective Detector Base

    The detector base for field devices HI520 and OP520.

    Data sheet A5Q00016382A

    A6C50000011

  • 8/13/2019 Alarma Contraincendio Siemens

    20/28

    Detectors & PeripheralsAddressable Detectors and Bases

    2-6 Siemens Building Technologies Group

    Type Order No.

    BDS031 BDS031 Addressable Heat Detector (Rate of Rise and Fix Tempera-ture)

    BDS031 is a heat detectors which can be connected to the F-Bus

    l Newly developed circuit and sensor ensure high performance offixed and rate of rise temperature detection.

    l High stability against dust electromagnetic interference tempera-ture fluctuation humidity and corrosion.

    l Produced with SMT advanced technology.

    Operating voltage 16... 32 VDCOperating temperature -10... +50 CStorage temperature -30... +75 CRelative humidity 95 % (40 2 C)Quiescent current 1.0 mAAlarm current 3.0 mAEMC 10 V/mData sheet A5Q00016383A

    A6C50000001

    BDS051 BDS051 Addressable Optical Smoke Detector

    BDS051 is smoke detector which can be connected to the F-Bus.

    l Patented labyrinth optical structure.l New built-in ASIC ensures high reliability of data processing.l Homogeneous response to different kind of smoke.l High stability against dust electromagnetic interference tempera-

    ture fluctuation humidity and corrosion.l Produced with SMT advanced technology.

    Operating voltage 16... 32 VDCOperating temperature -10... +50 CStorage temperature -30... +75 CRelative humidity 95 % (40 2 C)Quiescent current 1.0 mAAlarm current 3.0 mAEMC 10 V/mData sheet A5Q00016384A

    A6C50000002

    BDS000 BDS000 Addressable Detector Base

    Detector base is for field devices BDS051 and BDS031.The detector covers the whole base the wiring capacity is 1.0 to 1.5mm.

    Data sheet A5Q00016385A

    A6C50000000

  • 8/13/2019 Alarma Contraincendio Siemens

    21/28

    Detectors & PeripheralsManual Call Points

    2-7 Siemens Building Technologies Group

    2

    Type Order No.

    BDS121 BDS121 Manual Call Point

    Manual call point can immediate trigger a fire alarm by breaking theglass.

    l Connected to F-Busl Installed in the public area such as staircase elevator lobby etcl Device address can be set via a DIP-switch.l A built-in dry contact can be used to activate another equipment.l Mounted on the wall 1.5 meters above the ground.l Electronic part and housing are delivered separately.

    Operating voltage 24 VDCOperating temperature -20... +55 CRelative humidity 95 % (40 2 C)Quiescent current 1 mAAlarm current 3.0 mACapacity of dry contact 24 VDC / 0.1 AEMC 10 V/mData sheet A5Q00016386A

    A6C50000003

  • 8/13/2019 Alarma Contraincendio Siemens

    22/28

    Detectors & PeripheralsAddressable Modules

    2-8 Siemens Building Technologies Group

    Type Order No.

    BDS132 BDS132 Input Module

    The input module serves as an interface to transmit alarms or technicalsignals from other equipments to the fire alarm control unit.

    l Connected to the F-Bus device address can be set with a DIP-switch.l Serves as interface for potential free signals from flow switches pres-

    sure switches etc to the fire alarm system.l The signal will be transmitted to the controller and trigger corre-

    sponding actions.l Connection faults will be automatically detected and displayed on

    the controller.

    Operating voltage 24 VDCOperating temperature -20... +55 CRelative humidity 95 % (40 2 C)Activation current 3 m A

    Quiescent current 1 mAWiring Capacity 1.0 1.5 mmData sheet A5Q00016394A

    A6C50000004

    BDS152 BDS152 Isolation Module

    The isolation module is used to isolate a short circuit on the detectionbus. The device will automatically recover to its normal status when thecause of the short circuit disapears.

    l The isolation module separates a short circuit on the F-Bus.l Parallel connection on the first place of each branch or stub is possi-

    ble.l No device address is required.l When a single loop is used to connect devices mounted on several

    floors it is recommended to install one isolation module on eachfloor.

    l Up to 25 field devices can be mounted to an isolation module.l The connection is polarity free.l Faults will be automatically detected and displayed on the controller.

    Operating temperature -20... +50 CRelative humidity 95 % (40 2 C)Activation current 0.5 mAPass through voltage 1 VDCWiring Capacity 1.0... 1.5 mmData sheet A5Q00016395A

    A6C50000005

  • 8/13/2019 Alarma Contraincendio Siemens

    23/28

    Detectors & PeripheralsAddressable Modules

    2-9 Siemens Building Technologies Group

    2

    Type Order No.

    BDS161 BDS161 Collective Input Module

    Collective input module can connect collective detectors to the F-Bus

    l Directly connected to the F-Bus addresses are set with a DIP-switchl Up to 15 collective detectors can be connected to the modulel An end of line element P6KE18CA has to be used.l Module transmits alarm fault and danger level signal to the control

    unitl The same indications are displayed on the module.l Connection is polarity free.l Faults will be automatically detected and displayed on the control

    unit.

    Alarm voltage 3.7... 16.4 VDCFault voltage 0... 3.7 VDC (short)

    22.1 VDC (open)

    Normal voltage 16.4... 22.1 VDCAlarm current

  • 8/13/2019 Alarma Contraincendio Siemens

    24/28

    Spare Parts & Upgrades

    3-10 Siemens Building Technologies Group

    Type Order No.

    TP8000 TP8000 Printer

    A thermal sensitive printer is used to print events.

    Data sheet A5Q00016403A

    A6C50000028

    BCE8001 BCE8001 Extension Card

    Extension card for BC8001 compact controller.This card contains the following interfaces:

    l A-Bus interface to add the network feature to the compact controller(networkable up to 32 controllers).

    l B-Bus interface to allow BC8001 to connect up to 3 B-Bus devices.l F-Bus interface for additional up to 127 devices.

    Data sheet A5Q00016402A

    A6C50000024

    BCC8001 BCC 8001 Main Board of BC80 Compact

    Data sheet A5Q00016405A

    A6C50000035

    BT8002 BT8002 Operation Panel

    The BT8002 is the operation panel of BC8002 Advanced Control Unit.

    l The operation panel consists of the main board BCC8002 the CPUboard BCC8011 LCD and the keypads and LED's as indicators.

    l Connected with other control units via A-Bus.l Connected with interlocking panels line cards extinguishing panels

    via B-Bus.l Download/Upload port on the CPU board.l BT8002 Operation panel features also numerical keys and loud

    speaker.l A communication port for connection to a management station is

    built-in.

    Data sheet A5Q00016413A

    A6C50000034

  • 8/13/2019 Alarma Contraincendio Siemens

    25/28

    Spare Parts & Upgrades

    3-11 Siemens Building Technologies Group

    3

    Type Order No.

    BCB8001 BCB8001 Wall-mounted Power Supply (8A)

    Input voltage 220 VAC / 50HZ187... 242 VAC (Effective)

    Output voltage 20... 28 VDC / 8 A (Main power ork-ing)24 VDC (Only battery working)

    Operating temperature -10... 50 CRelative humidity 95 % RhProtection Output 8.0 * 110 % (Over current

    protection)Output 1.0 (Output short pro-tection)Voltage

  • 8/13/2019 Alarma Contraincendio Siemens

    26/28

    Spare Parts & Upgrades

    3-12 Siemens Building Technologies Group

    Type Order No.

    BCM8001 BCM8001 Line Card for BC8002 Advanced Control Unit

    The BCM8001 is the line card connecting BDS field devices

    l Each BCM8001 can connect 4 loops; each loop can connect up to127 devices.

    l Overload protection: recovers to normal status when the cause ofoverload disappears.

    l B-Bus address is set with a DIP-switch on the board.

    Number of loops 4Number of addresses 127 (on one loop)Max. load factor 150 (for each loop)Wiring Capacity RVS1.0... RVS1.5Max. distance per line 1000 mResistor per line 300 Capacitor per line 300 nFProtection Short protection

    Over voltage protectionConnectable field devices BDS SeriesOperating voltage Modulated 16... 32 VDCQuiescent current Full load: 200 mA

    No Load: 110 mAData sheet A5Q00016410A

    A6C50000037

  • 8/13/2019 Alarma Contraincendio Siemens

    27/28

    Type Index

    1 Siemens Building Technologies Group

    Type Description Order No. PageBC8001 BC8001 Compact Control Unit with 1 F-Bus line for up to

    127 DevicesA6C50000016 1-1

    BC8001.. BC8001 Compact Control Unit BC8001.. 1-1BC8001E BC8001E Compact Control Unit with 2 F-Bus lines for up to 254

    DevicesA6C50000017 1-2

    BC8001P BC8001P Compact Control Unit with 1F-Bus line and printer A6C50000018 1-1BC8001PE BC8001PE Compact Control Unit with 2 F-Bus lines and printer A6C50000019 1-2BC8002-1 BC8002-1/e wall-mounted Advanced Control Unit for up to 500

    devices 4 loopsA6C50000029 1-2

    BC8002-2 BC8002-2 w all-mounted Advanced Control Unit for up to 1000devices

    A6C50000030 1-3

    BC8002-3 BC8002-3 wall-mounted Advanced Control Unit forv1500 devices A6C50000031 1-3BC8002.. BC8002-1/e wall-mounted Advanced Control Unit BC8002.. 1-2BC8013 BC8013 Extinguishing Panel A6C50000038 1-4BC8013.. BC8013 Extinguishing Panel BC8013.. 1-4BC8013H BC8013H wall-mounted Extinguishing Panel A6C50000022 1-4BCB8001 BCB8001 Wall-mounted Power Supply (8A) A6C50000039 3-11BCC8001 BCC 8001 Main Board of BC80 Compact A6C50000035 3-10BCC8002 BCC8002 Main Board of BC8002 Advanced Control Unit A6C50000036 3-11BCE8001 BCE8001 Extension Card A6C50000024 3-10BCM8001 BCM8001 Line Card for BC8002 Advanced Control Unit A6C50000037 3-12BDS000 BDS000 Addressable Detector Base A6C50000000 2-6BDS031 BDS031 Addressable Heat Detector (Rate of Rise and Fix Temper-

    ature)A6C50000001 2-6

    BDS051 BDS051 Addressable Optical Smoke Detector A6C50000002 2-6BDS121 BDS121 Manual Call Point A6C50000003 2-7

    BDS132 BDS132 Input Module A6C50000004 2-8BDS152 BDS152 Isolation Module A6C50000005 2-8BDS161 BDS161 Collective Input Module A6C50000006 2-9BDS221 BDS221 Output Module A6C50000007 2-9BT80.. BT8011 / BT8012 Interlocking Panel BT80.. 1-3BT8002 BT8002 Operation Panel A6C50000034 3-10BT8011 BT8011 Interlocking Panel A6C50000032 1-3BT8012 BT8012 Interlocking Panel (without printer) A6C50000033 1-3HI520 HI520 Collective Heat Detector (Rate of Rise and Fix Temperature) A6C50000009 2-5OP520 OP520 Collective Optical Smoke Detector A6C50000010 2-5SO520 SO520 Collective Detector Base A6C50000011 2-5TP8000 TP8000 Printer A6C50000028 3-10

  • 8/13/2019 Alarma Contraincendio Siemens

    28/28

    Siemens Switzerland LtdBuilding Technologies GroupInternational HeadquartersGubelstrasse 22CH-6301 ZugTel +41 41 724 24 24Fax +41 41 724 35 22

    The information in this document contains general descriptions of technical options available,which do not always have to be present in individual cases. The required features should thereforebe specified in each individual case at the time of closing the contract.

    Windows is a registered trademark of Microsoft Corporation

    Subject to change Order no. 0-92065-en Siemens Switzerland Ltd Printed in Switzerland 10705 Ah