  • Title page

    Alcatel-Lucent 9326

    digital 2U Node B V2 | V7.1

    Maintenance Guide

    NN-20500-204

    ISSUE 4.05

    MAY 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    Use pursuant to applicable agreements

  • Legal notice

    Legal notice

    Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective

    owners.

    The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.

    Copyright 2010 Alcatel-Lucent. All rights reserved.

    Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside

    Alcatel-Lucent without its written authorization.

    Not to be used or disclosed except in accordance with applicable agreements.

    Use pursuant to applicable agreements

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

  • Contents

    About this document

    Purpose ............................................................................................................................................................................................. ixix

    Reason for revision ...................................................................................................................................................................... ixix

    New in this release ....................................................................................................................................................................... ixix

    Intended audience ......................................................................................................................................................................... ixix

    Supported systems ........................................................................................................................................................................ ixix

    How to use this document ........................................................................................................................................................... xx

    Safety information ......................................................................................................................................................................... xx

    Prerequisites ..................................................................................................................................................................................... xx

    Conventions used ........................................................................................................................................................................... xx

    Related information ....................................................................................................................................................................... xx

    Document support ........................................................................................................................................................................ xixi

    Technical support .......................................................................................................................................................................... xixi

    How to order ................................................................................................................................................................................... xixi

    How to comment ........................................................................................................................................................................... xixi

    1 Roadmap to Distributed Base Stations documentation

    Overview ....................................................................................................................................................................................... 1-11-1

    Roadmap to Distributed Base Stations documentation ................................................................................................ 1-21-2

    2 Safety statements

    Overview ....................................................................................................................................................................................... 2-12-1

    Structure of safety statements ................................................................................................................................................ 2-22-2

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    iii

  • 3 Corrective maintenance activity

    Overview ....................................................................................................................................................................................... 3-13-1

    Corrective maintenance activity ........................................................................................................................................... 3-23-2

    4 9326 d2U V2 introduction

    Overview ....................................................................................................................................................................................... 4-14-1

    9326 d2U V2 introduction ...................................................................................................................................................... 4-24-2

    5 9326 d2U V2 hardware presentation

    Overview ....................................................................................................................................................................................... 5-15-1

    9326 d2U V2 hardware presentation .................................................................................................................................. 5-25-2

    6 9326 d2U V2 power up and power down procedures

    Overview ....................................................................................................................................................................................... 6-16-1

    Powering up a 9326 d2U V2 ................................................................................................................................................. 6-26-2

    Powering down a 9326 d2U V2 ........................................................................................................................................... 6-36-3

    7 9326 d2U V2 corrective maintenance procedures

    Overview ....................................................................................................................................................................................... 7-17-1

    Replacing the digital shelf equipment

    Overview ....................................................................................................................................................................................... 7-27-2

    Replacing an iCEM-U .............................................................................................................................................................. 7-37-3

    Replacing an xCEM-U ............................................................................................................................................................. 7-67-6

    Replacing the iCCM-U ............................................................................................................................................................ 7-97-9

    Replacing the xCCM-U ........................................................................................................................................................ 7-147-14

    Replacing an optical transceiver ........................................................................................................................................ 7-207-20

    Replacing the fans rack (48V) ............................................................................................................................................ 7-237-23

    Replacing the pre-cabled 9326 d2U V2 rack ................................................................................................................ 7-287-28

    Replacing the optional equipment

    Overview .................................................................................................................................................................................... 7-387-38

    Replacing the External Alarm module ............................................................................................................................. 7-397-39

    Replacing the LPPCM module ........................................................................................................................................... 7-417-41

    Contents

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    iv Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • A Product conformance statements

    Overview ...................................................................................................................................................................................... A-1A-1

    European regulatory requirement compliance ............................................................................................................... A-2A-2

    North American regulatory requirement compliance .................................................................................................. A-4A-4

    Compliances for other regions/countries ......................................................................................................................... A-7A-7

    Operating conditions ............................................................................................................................................................... A-8A-8

    Cable specifications ................................................................................................................................................................. A-9A-9

    Product labeling ...................................................................................................................................................................... A-10A-10

    Contents

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    v

  • List of figures

    1-1 Roadmap to Distributed Base Stations documentation ................................................................................ 1-31-3

    4-1 Outside view of the 9326 d2U V2 ....................................................................................................................... 4-34-3

    5-1 9326 d2U V2 front view (with iCCM-U) ......................................................................................................... 5-25-2

    5-2 9326 d2U V2 front view (with xCCM-U) ........................................................................................................ 5-25-2

    7-1 iCEM-U front panel .................................................................................................................................................. 7-37-3

    7-2 xCEM-U front panel ................................................................................................................................................. 7-67-6

    7-3 iCCM-U board front panel ..................................................................................................................................... 7-97-9

    7-4 xCCM-U-4E1 configuration front panel ........................................................................................................ 7-147-14

    7-5 xCCM-U-GE configuration front panel .......................................................................................................... 7-147-14

    7-6 Location of optical connectors in the 9326 d2U V2 ................................................................................... 7-217-21

    7-7 Inserting an SFP transceiver in the iCCM-U ................................................................................................ 7-227-22

    7-8 9326 d2U V2 front view (with iCCM-U) ....................................................................................................... 7-237-23

    7-9 9326 d2U V2 front view (with xCCM-U) ...................................................................................................... 7-237-23

    7-10 Extracting the fans rack ........................................................................................................................................ 7-257-25

    7-11 Fans rack .................................................................................................................................................................... 7-257-25

    7-12 9326 d2U V2 front view (with iCCM-U) ....................................................................................................... 7-287-28

    7-13 9326 d2U V2 front view (with xCCM-U) ...................................................................................................... 7-287-28

    7-14 Location of the management sticker ................................................................................................................ 7-307-30

    7-15 Front panel of the External Alarm module .................................................................................................... 7-397-39

    7-16 LPPCM module front panel ................................................................................................................................ 7-417-41

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    vii

  • About this documentAbout this document

    Purpose

    The purpose of this document is to describe corrective maintenance procedures applicable

    to the 9326 d2U V2 rack.

    Reason for revision

    The reissue reasons are:

    Issue number Issue date Reason for reissue

    4.05 May 2010 Standard issue

    4.04 March 2010 Preliminary issue

    4.03 February 2010 Preliminary issue

    4.02 November 2009 Preliminary issue

    4.01 October 2009 Draft issue

    New in this release

    New features:

    74759 Gigabit Ethernet MDA for xCCM, see Replacing the xCCM-U (p. 7-14)

    Important! The availability of the features listed above on the hardware equipment

    should be checked with your Alcatel-Lucent representative.

    Other changes:

    Reformat to comply with current documentation standards

    Intended audience

    The audience for this document is Operations and maintenance personnel and those who

    want to know the principles of 9326 d2U V2 maintenance.

    Supported systems

    This document applies to Alcatel-Lucent W-CDMAV7.1 system release.

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    ix

  • How to use this document

    No specific recommendation applies regarding the way readers should read this

    document.

    Safety information

    For your safety, this document contains safety statements. Safety statements are given at

    points where risks of damage to personnel, equipment, and operation may exist. Failure to

    follow the directions in a safety statement may result in serious consequences.

    Prerequisites

    It is recommended that readers become familiar with the following documents:

    Alcatel-Lucent 9326 digital 2U Node B V2 - Technical Description, NN-20500-203

    Alcatel-Lucent 93xx Node B Commissioning and Fault Management User Manual:

    TIL, NN-20500-019

    Conventions used

    Vocabulary conventions

    For a list of terms used in this document, see Alcatel-Lucent W-CDMA System -

    Terminology, NN-20500-002.

    Typographical conventions

    The following typographical conventions are used in this document:

    Appearance Description

    Italicized text Emphasized information

    graphical user interface text Text that is displayed in a graphical user interface or

    in a hardware label

    Document reference, reference number Related document that is referenced in the document

    Related information

    For information on subjects related to the content of this document, refer to the

    documents listed in the following table:

    Refer to this document At this location For more information on

    Alcatel-Lucent W-CDMA

    System - Terminology,

    NN-20500-002

    http://support.alcatel-

    lucent.com.

    Terms used in Alcatel-Lucent

    W-CDMA documents.

    Alcatel-Lucent 9326 digital

    2U Node B V2 - Technical

    Description, NN-20500-203

    http://support.alcatel-

    lucent.com.

    The Alcatel-Lucent 9326

    digital 2U Node B V2:

    Basic characteristics

    Hardware description

    About this document

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    x Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • Refer to this document At this location For more information on

    Alcatel-Lucent 9353

    Wireless Management

    System - Node B Alarms

    Reference Guide for 9311,

    9312, 9322, 9326, 9332

    Node B, NN-20500-018P1

    http://support.alcatel-

    lucent.com.

    Alarm descriptions and

    maintenance actions required

    for Alcatel-Lucent Node Bs.

    Alcatel-Lucent 9353

    Wireless Management

    System - User Guide,

    NN-20500-032

    http://support.alcatel-

    lucent.com.

    How to perform commands

    available in the 9353 Wireless

    Management System (WMS)

    Graphical User Interface

    (GUI).

    Alcatel-Lucent 93xx Node B

    Commissioning and Fault

    Management User Manual:

    TIL, NN-20500-019

    http://support.alcatel-

    lucent.com.

    How to perform the Node B

    installation, commissioning

    and maintenance tasks using

    the Node B TIL (Terminal for

    Local Installation) tool.

    Alcatel-Lucent W-CDMA

    System Safety Guide,

    401-382-880

    http://support.alcatel-

    lucent.com.

    Safety guidelines and the

    catalog of hazard statements

    that appear in the

    Alcatel-Lucent W-CDMA

    customer documents.

    Document support

    For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at

    one of the following telephone numbers:

    1-888-582-3688 (for the United States)

    1-317-377-8618 (for all other countries)

    Technical support

    For technical support, contact your local Alcatel-Lucent customer support team. See the

    Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact

    information.

    How to order

    To order Alcatel-Lucent documents, contact your local sales representative or use Online

    Customer Support (OLCS) (http://support.alcatel-lucent.com)

    How to comment

    To comment on this document, go to the Online Comment Form (http://infodoc.

    alcatel-lucent.com/comments/enus/) or e-mail your comments to the Comments Hotline

    ([email protected]).

    About this document

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    xi

  • 1 1Roadmap to Distributed

    Base Stations

    documentation

    Overview

    Purpose

    This chapter provides the roadmap for Distributed Base Stations documentation.

    Contents

    Roadmap to Distributed Base Stations documentation 1-2

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    1-1

  • Roadmap to Distributed Base Stations documentation

    The following figure shows where the current document stands within the W-CDMA

    customer documentation.

    For a global view of the W-CDMA customer documentation, see the Roadmap chapter in:

    Alcatel-Lucent W-CDMA System - Document Collection Overview, NN-20500-050

    Alcatel-Lucent W-CDMA System - Access Network Elements Overview,

    NN-20500-233

    Roadmap to Distributed Base Stations documentation Roadmap to Distributed Base Stations documentation

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    1-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • Figure 1-1 Roadmap to Distributed Base Stations documentation

    Roadmap to Distributed Base Stations documentation Roadmap to Distributed Base Stations documentation

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    1-3

  • 2 2Safety statements

    Overview

    Purpose

    This chapter provides information on the structure of safety statements which may arise

    in the course of your work.

    Contents

    Structure of safety statements 2-2

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    2-1

  • Structure of safety statements

    Overview

    Safety statements describe the safety risks relevant while performing tasks on

    Alcatel-Lucent products during deployment and/or use. Failure to avoid the hazards may

    have serious consequences.

    General structure

    Safety statements include the following structural elements:

    Item Structure element Purpose

    1 Safety alert symbol Indicates the potential for personal injury

    (optional)

    2 Safety symbol Indicates hazard type (optional)

    3 Signal word Indicates the severity of the hazard

    4 Hazard type Describes the source of the risk of damage or

    injury

    5 Safety message Consequences if protective measures fail

    6 Avoidance message Protective measures to take to avoid the hazard

    7 Identifier The reference ID of the safety statement

    (optional)

    Signal words

    The signal words identify the hazard severity levels as follows:

    Signal word Meaning

    DANGER Indicates an extremely hazardous situation which, if not avoided, will

    result in death or serious injury.

    Lifting this equipment by yourself can result in injurydue to the size and weight of the equipment.Always use three people or a lifting device to transportand position this equipment. [ABC123]

    CAUTION

    Lifting hazard

    B C D

    E F

    G

    H

    Safety statements Structure of safety statements

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    2-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • Signal word Meaning

    WARNING Indicates a hazardous situation which, if not avoided, could result in

    death or serious injury.

    CAUTION Indicates a hazardous situation which, if not avoided, could result in

    minor or moderate injury.

    NOTICE Indicates a hazardous situation not related to personal injury.

    Safety statements Structure of safety statements

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    2-3

  • 3 3Corrective maintenance

    activity

    Overview

    Purpose

    This chapter describes the corrective maintenance activity applicable to the 9326 d2U V2

    rack.

    Contents

    Corrective maintenance activity 3-2

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    3-1

  • Corrective maintenance activity

    Corrective maintenance

    The network maintenance is based on the supervision of the network, by using the OAM

    graphical interface. For more information, refer to Alcatel-Lucent 9353 Wireless

    Management System - User Guide, NN-20500-032.

    It is also based on the identification and replacement of faulty items of equipment, using

    the alarms.

    The process is divided into the following two steps:

    Locating and identifying the faulty items of equipment, by using the information

    provided in Alcatel-Lucent 9353 Wireless Management System - Node B Alarms

    Reference Guide for 9311, 9312, 9322, 9326, 9332 Node B, NN-20500-018P1

    Replacing the faulty items of equipment, by using the replacement procedures given

    in this document

    Note: The iModules replacement procedures described in this guide are based on the

    following assumptions:

    Your 9326 d2U V2 is equipped with the following digital modules:

    One iCCM-U upgraded with the specific adapter board and front panel (iCCM-U

    V2)

    One xCEM-U (mandatory) and possibly up to two additional xCEMs-U

    Possibly up to two iCEMs-U upgraded with the specific adapter boards and front

    panels (iCEMs-U V2)

    As spare parts, you ordered iCEMs-U V2 and iCCMs-U V2 modules (order codes:

    3JR08057AA and 3JR08056AA).

    Replacing the digital shelf equipment

    Procedure Order Code Impact on service

    Replacing an iCEM-U

    (p. 7-3)

    3JR08057AA Loss of capacity or loss of service

    (depending on the number of CEMs in

    the digital shelf)

    Replacing an xCEM-U

    (p. 7-6)

    300986049 Loss of capacity or loss of service

    (depending on the number of CEMs in

    the digital shelf)

    Replacing the iCCM-U

    (p. 7-9)

    3JR08056AA Loss of service on the Remote Radio

    device(s) associated with the iCCM-U

    being replaced

    Replacing the xCCM-U

    (p. 7-14)

    3JR20038AA Loss of service on the Remote Radio

    device(s) associated with the xCCM-U

    being replaced

    Corrective maintenance activity Corrective maintenance activity

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    3-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • Procedure Order Code Impact on service

    Replacing an optical

    transceiver (p. 7-20)

    Single-Mode (SM):

    NTU850HA

    Loss of service on the Remote Radio

    device associated with the optical

    transceiver being replacedMulti-Mode (MM):

    NTU850HM

    Replacing the fans rack

    (48V) (p. 7-23)

    3JR08021AA Service interruption

    Replacing the pre-cabled

    9326 d2U V2 rack

    (p. 7-28)

    3JR08067AA Service interruption

    Replacing the optional equipment

    Procedure Order Code Impact on service

    Replacing the LPPCM

    module (p. 7-41)

    NTU870GM Service interruption

    Replacing the External

    Alarm module (p. 7-39)

    NTU870GA None

    Description of a replacement procedure

    A replacement procedure is divided into the following parts:

    The title

    The main body with the following information:

    The intervention time

    The tools required

    The impact of the procedure, if necessary

    The step-by-step actions of the procedure

    One or more figures are provided to help you execute the actions. They show the FRU

    schematically and its location in the cabinet.

    Intervention restrictions

    There may be a lapse of time between the identification of the alarm at the Access OAM

    Graphic User Interface (GUI) and the time you arrive at the site.

    You must be synchronized with the access network controller or system administrator (by

    telephone) before an on-site intervention, in the following cases:

    Isolating procedures

    Completion of an on-site intervention

    Return to service procedure

    Corrective maintenance activity Corrective maintenance activity

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    3-3

  • General personnel safety instructions

    The personnel must obey the safety instructions specific to the installation site:

    Rules concerning the premises (see instructions posted on site or in the building)

    Rules linked to general personnel safety instructions

    The personnel working on the cabinet must be authorized to work according to security

    standards.

    Equipment safety instructions

    The 9326 d2U V2 normally operates when the external temperature is between 5C and

    +65C.

    Corrective maintenance activity Corrective maintenance activity

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    3-4 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • 4 49326 d2U V2 introduction

    Overview

    Purpose

    This chapter introduces the 9326 d2U V2.

    Contents

    9326 d2U V2 introduction 4-2

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    4-1

  • 9326 d2U V2 introduction

    The 9326 d2U V2 is the enhanced 9326 d2U rack supporting xModules (xCEM-U,

    xCCM-U). It is designed to be connected to one of the following products via optical

    fiber links:

    RRH60-21

    RRH40-AWS

    RRH40-21

    RRH40-08

    RRH40-19

    RRH20-21

    9332 rCompact

    The iModules (iCEM-U, iCCM-U) can be plugged in this 9326 d2U V2 rack, using

    specific adapter boards and front panels.

    xCEM-U and iCEM-U modules can be mixed inside the 9326 d2U V2 rack. The 9326

    d2U V2 rack is factory-equipped with one xCCM-U or one iCCM-U (in slot 1), one

    xCEM-U (in slot 2) and two fillers. Depending on the capacity requirements, the 9326

    d2U V2 rack can host two xCEMs-U, two iCEMs-U, or one xCEM-U and one iCEM-U

    in place of the two fillers (slot 3 and slot 4).

    The Alcatel-Lucent Remote Radio solution improves flexibility for deploying mobile

    broadband Node Bs in space-constrained locations. It is particularly suited to

    macro-cellular applications in dense areas, where site acquisition is difficult, and on sites

    where installation constraints prevent the use of legacy Node Bs.

    Compared to legacy Node B site deployment, the Remote Radio solution provides the

    following benefits:

    Reduced volume, weight, footprint, acoustic noise, and power consumption

    Reduced cost of feeder paths from the Node B to the antenna

    Increased RF power per carrier at the antenna feeder

    Reduced radio loss with use of the remote RF block concept, which eliminates the

    distance between the radio amplifier and the antenna

    The Remote Radio solution provides for the UMTS system:

    The means of communication between a User Equipment (UE) and a network using

    Transport Channels

    Physical layer channels, which are necessary to synchronize the downlink and

    perform cell selection/reselection and handover preparation

    Measurement information to the RNC for radio resource management (handover,

    power control)

    The 9326 d2U V2 provides up to eight E1/T1 with Inversion Multiplexing ATM (IMA) or

    Drop-and-Insert capability (fractional E1/T1). The 9326 d2U V2 also supports

    multi-PCM without IMA.

    9326 d2U V2 introduction 9326 d2U V2 introduction

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    4-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • The 9326 d2U V2 delivers high UMTS radio performances and supports the enhanced

    High Speed Downlink Packet Access (HSDPA) and High Speed Uplink Packet Access

    (HSUPA) solutions through easy software upgrade.

    The 9326 d2U V2 is compliant with the Common Public Radio Interface (CPRI).

    9326 d2U V2 enclosure

    The 9326 d2U V2 provides the operators with a suited solution whatever the site

    constraints.

    The 9326 d2U V2 can be installed in a standalone indoor mode or in an existing indoor or

    outdoor Alcatel-Lucent 9100 Multi-Standard Base Station cabinet for multi-standard

    configuration.

    Moreover, the 9326 d2U V2 can be integrated in a small or a medium Power Supply Unit

    (PSU) outdoor cabinet.

    The following figure shows an outside view of the 9326 d2U V2.

    Figure 4-1 Outside view of the 9326 d2U V2

    9326 d2U V2 introduction 9326 d2U V2 introduction

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    4-3

  • 5 59326 d2U V2 hardware

    presentation

    Overview

    Purpose

    This chapter describes the hardware of the 9326 d2U V2 rack.

    Contents

    9326 d2U V2 hardware presentation 5-2

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    5-1

  • 9326 d2U V2 hardware presentation

    The 9326 d2U V2 is built around the following components:

    Amechanical enclosure (including two fans), compatible with standard 19-inch rack

    installation

    A digital shelf including the digital modules and the associated digital backplane

    A commissioning module located on the right hand side of the digital shelf

    The following figure shows a front view of the 9326 d2U V2 equipped with iCCM-U.

    The following figure shows a front view of the 9326 d2U V2 equipped with xCCM-U.

    Figure 5-1 9326 d2U V2 front view (with iCCM-U)

    Figure 5-2 9326 d2U V2 front view (with xCCM-U)

    9326 d2U V2 hardware presentation 9326 d2U V2 hardware presentation

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    5-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • 6 69326 d2U V2 power up

    and power down

    procedures

    Overview

    Purpose

    This chapter describes how to power up and power down the 9326 d2U V2.

    Contents

    Powering up a 9326 d2U V2 6-2

    Powering down a 9326 d2U V2 6-3

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    6-1

  • Powering up a 9326 d2U V2

    Perform the following procedure to power up a 9326 d2U V2.

    Initial check

    On the RUC module, check that the power switch is in the "O" position.

    Procedure

    ...................................................................................................................................................................................................

    1 At the operator DC power supply, put the site circuit breaker of the 9326 d2U V2 in the

    "ON" position.

    ...................................................................................................................................................................................................

    2 On the RUC module, put the power switch in the "1" position.

    ...................................................................................................................................................................................................

    3 Check that the fans are starting up.

    ...................................................................................................................................................................................................

    4 On the iCCM-U/xCCM-U and on each iCEM-U/xCEM-U, check that:

    The green LED is ON.

    The red LED is OFF.

    9326 d2U V2 power up and power down procedures Powering up a 9326 d2U V2

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    6-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

    E N D O F S T E P S...................................................................................................................................................................................................

  • Powering down a 9326 d2U V2

    Perform the following procedure to power down a 9326 d2U V2.

    Procedure

    ...................................................................................................................................................................................................

    1 Preliminary operation: make sure that the btsSiteManager object is "locked".

    ...................................................................................................................................................................................................

    2 On the RUC module, put the power switch in the "O" position.

    ...................................................................................................................................................................................................

    3 Check that the green or red LED on the iCCM-U/xCCM-U and on each

    iCEM-U/xCEM-U is OFF.

    ...................................................................................................................................................................................................

    4 Check that the fans are stopping down.

    ...................................................................................................................................................................................................

    5 At the operator DC power supply, put the site circuit breaker of the 9326 d2U V2 in the

    "OFF" position.

    9326 d2U V2 power up and power down procedures Powering down a 9326 d2U V2

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    6-3

    E N D O F S T E P S...................................................................................................................................................................................................

  • 7 79326 d2U V2 corrective

    maintenance procedures

    Overview

    Purpose

    This chapter contains the replacement procedures applicable to the 9326 d2U V2 rack.

    Note:

    1. For detailed information on PSU maintenance, refer to the documentation

    provided within the PSU cabinet.

    2. For detailed information on Alcatel-Lucent 9100 Multi-Standard Base Station

    maintenance, refer to the documentation related to the Alcatel-Lucent 9100

    Multi-Standard Base Station cabinets.

    Contents

    Replacing the digital shelf equipment 7-2

    Replacing an iCEM-U 7-3

    Replacing an xCEM-U 7-6

    Replacing the iCCM-U 7-9

    Replacing the xCCM-U 7-14

    Replacing an optical transceiver 7-20

    Replacing the fans rack (48V) 7-23

    Replacing the pre-cabled 9326 d2U V2 rack 7-28

    Replacing the optional equipment 7-38

    Replacing the External Alarm module 7-39

    Replacing the LPPCM module 7-41

    ...................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-1

  • Replacing the digital shelf equipment

    Overview

    Purpose

    This section presents the replacement procedures applicable to the digital shelf.

    Those replacement procedures concern the following modules:

    integrated Channel Element Module-U (iCEM-U) or eXtended Channel Element

    Module-U (xCEM-U)

    integrated Core Controller Module-U (iCCM-U) or eXtended Core Controller

    Module-U (xCCM-U)

    Optical transceiver

    Fans rack (48V)

    Pre-cabled 9326 d2U V2 rack

    Contents

    Replacing an iCEM-U 7-3

    Replacing an xCEM-U 7-6

    Replacing the iCCM-U 7-9

    Replacing the xCCM-U 7-14

    Replacing an optical transceiver 7-20

    Replacing the fans rack (48V) 7-23

    Replacing the pre-cabled 9326 d2U V2 rack 7-28

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Overview

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-2 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • Replacing an iCEM-U

    Carry out the following procedure to replace an iCEM-U.

    Intervention time

    15 minutes

    Tools required

    Screwdrivers

    Extraction tool

    NOTICE

    ESD hazard

    Electronic components can be destroyed by electrostatic discharge (ESD).

    Hold circuit packs only at the edges or on the insertion and removal facilities.

    Always observe the general ESD instructions.

    NOTICE

    Service-disruption hazard

    Following the procedure below will result in a loss of capacity or a loss of service

    (depending on the number of CEMs housed in the 9326 d2U V2 rack).

    Procedure

    ...................................................................................................................................................................................................

    1 Locate the faulty iCEM-U in the 9326 d2U V2 rack: its red triangular LED is ON.

    Figure 7-1 iCEM-U front panel

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing an iCEM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-3

  • ...................................................................................................................................................................................................

    2 Lock the faulty cem object at the OMC by Set Administrative State.

    For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User

    Guide, NN-20500-032.

    ...................................................................................................................................................................................................

    3 Undo and remove the upper hook (if present and if the defective iCEM-U is in slot 4).

    ...................................................................................................................................................................................................

    4 Loosen the two screws on the defective iCEM-U front panel.

    ...................................................................................................................................................................................................

    5 Remove the defective iCEM-U using the extraction tool.

    ...................................................................................................................................................................................................

    6 If you are to replace the defective iCEM-U with a xCEM-U, go to step 6 of the procedure

    Replacing an xCEM-U (p. 7-6).

    If you are to replace the defective iCEM-U with a new iCEM-U, check the release of the

    new iCEM-U.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing an iCEM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-4 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • ...................................................................................................................................................................................................

    7 Insert the new iCEM-U into the 9326 d2U V2 rack, in the same slot as the defective

    iCEM-U.

    ...................................................................................................................................................................................................

    8 Tighten the two screws on the iCEM-U front panel.

    ...................................................................................................................................................................................................

    9 Put the hook back in place and secure it.

    ...................................................................................................................................................................................................

    10 From the OMC, unlock the cem object previously locked on step 2.

    ...................................................................................................................................................................................................

    11 Check the state of the LEDs. They should go on, then take the following state:

    red triangular LED OFF and green rectangular LED ON.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing an iCEM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-5

    E N D O F S T E P S...................................................................................................................................................................................................

  • Replacing an xCEM-U

    Carry out the following procedure to replace an xCEM-U.

    Intervention time

    Ten minutes

    Tools required

    Screwdriver

    Extraction tool

    NOTICE

    ESD hazard

    Electronic components can be destroyed by electrostatic discharge (ESD).

    Hold circuit packs only at the edges or on the insertion and removal facilities.

    Always observe the general ESD instructions.

    NOTICE

    Service-disruption hazard

    Following the procedure below will result in a loss of capacity or a loss of service

    (depending on the number of CEMs housed in the 9326 d2U V2 rack).

    Procedure

    ...................................................................................................................................................................................................

    1 Locate the faulty xCEM-U in the 9326 d2U V2 rack: its red LED is ON.

    Figure 7-2 xCEM-U front panel

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing an xCEM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-6 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • ...................................................................................................................................................................................................

    2 Lock the faulty cem object at the OMC by Set Administrative State.

    For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User

    Guide, NN-20500-032.

    ...................................................................................................................................................................................................

    3 Undo and remove the upper hook (if present and if the defective xCEM-U is in slot 4).

    ...................................................................................................................................................................................................

    4 Loosen the two screws on the xCEM-U front panel.

    ...................................................................................................................................................................................................

    5 Remove the defective xCEM-U using the extraction tool.

    ...................................................................................................................................................................................................

    6 Check the release of the new xCEM-U.

    ...................................................................................................................................................................................................

    7 Insert the new xCEM-U into the 9326 d2U V2 rack, in the same slot as the defective

    xCEM-U.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing an xCEM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-7

  • ...................................................................................................................................................................................................

    8 Tighten the two screws on the xCEM-U front panel.

    ...................................................................................................................................................................................................

    9 Put the hook back in place and secure it.

    ...................................................................................................................................................................................................

    10 From the OMC, unlock the cem object previously locked on step 2.

    ...................................................................................................................................................................................................

    11 Check the state of the LEDs. They should go on, then take the following state:

    red triangular LED OFF and green rectangular LED ON.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing an xCEM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-8 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

    E N D O F S T E P S...................................................................................................................................................................................................

  • Replacing the iCCM-U

    Carry out the following procedure to replace the iCCM-U.

    Intervention time

    20 minutes

    Tools required

    Screwdrivers

    Extraction tool

    DANGER

    Laser hazard

    This equipment operates with invisible laser radiation. Laser radiation can cause

    considerable injuries to the eyes.

    Never look into the end of an exposed fiber or into an open optical connector when the

    optical source is switched on. Always observe the laser warning instructions.

    NOTICE

    ESD hazard

    Electronic components can be destroyed by electrostatic discharge (ESD).

    Hold circuit packs only at the edges or on the insertion and removal facilities.

    Always observe the general ESD instructions.

    Figure 7-3 iCCM-U board front panel

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the iCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-9

  • NOTICE

    Service-disruption hazard

    Following the procedure below will result in a loss of service.

    Important! The spare iCCM-U software load must be UA05.1.2, otherwise the 9326

    d2U V2 can not start.

    Important! There will be a loss of service on the Remote Radio device(s) associated

    with the iCCM-U being replaced.

    Procedure

    ...................................................................................................................................................................................................

    1 Lock all the objects associated with the Remote Radio devices connected to the faulty

    iCCM-U at the OMC by Set Administrative State.

    For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User

    Guide, NN-20500-032.

    ...................................................................................................................................................................................................

    2 Power down the 9326 d2U V2.

    To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).

    ...................................................................................................................................................................................................

    3 Undo and remove the lower hook (if present).

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the iCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-10 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • ...................................................................................................................................................................................................

    4 Loosen the two screws on the defective iCCM-U front panel.

    ...................................................................................................................................................................................................

    5 Unplug the iCCM-U from its RBP connectors using the extraction tool.

    ...................................................................................................................................................................................................

    6 Disconnect the optical fiber(s) from the iCCM-U front panel.

    ...................................................................................................................................................................................................

    7 Remove the SFP transceiver(s) from the iCCM-U front panel.

    ...................................................................................................................................................................................................

    8 Disconnect the digital cable (connector labeled "ALARM") from the iCCM-U front

    panel.

    ...................................................................................................................................................................................................

    9 Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel.

    ...................................................................................................................................................................................................

    10 Extract the defective iCCM-U using the extraction tool.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the iCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-11

  • ...................................................................................................................................................................................................

    11 Insert the new iCCM-U into the slot guides without plugging it on the RBP.

    ...................................................................................................................................................................................................

    12 Reinsert the SFP transceiver(s) through the iCCM-U front panel.

    ...................................................................................................................................................................................................

    13 Important! In case of an iCCM-U equipped with MM SFP transceivers, when

    reconnecting the optical fibers on the iCCM-U front panel, put the LC connectors

    (L/R) in the same sense as they were before the intervention.

    Reconnect the optical fiber(s) on the iCCM-U front panel.

    ...................................................................................................................................................................................................

    14 Reconnect the digital cable on the iCCM-U front panel.

    ...................................................................................................................................................................................................

    15 Insert completely the new iCCM-U into the 9326 d2U V2 rack by plugging it into its RBP

    connectors.

    ...................................................................................................................................................................................................

    16 Tighten the two screws on the iCCM-U front panel.

    ...................................................................................................................................................................................................

    17 Put the hook back in place and secure it.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the iCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-12 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • ...................................................................................................................................................................................................

    18 Important! If the iCCM-U software load is not UA05.1.2, the 9326 d2U V2 can not

    start.

    Power up the 9326 d2U V2.

    To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)

    ...................................................................................................................................................................................................

    19 Reconnect the PCM E1/T1 cable on the iCCM-U front panel.

    ...................................................................................................................................................................................................

    20 Unlock from the OMC the objects previously locked through step 1.

    ...................................................................................................................................................................................................

    21 Check the state of the LEDs and display:

    The i/xCEM(s)-U and iCCM-U corporate LEDs should turn on, then take the

    following state:

    red LED OFF and green LED ON.

    The green PCM LEDs should be ON.

    The display should indicate the PCM synchronization.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the iCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-13

    E N D O F S T E P S...................................................................................................................................................................................................

  • Replacing the xCCM-U

    Carry out the following procedure to replace the xCCM-U.

    Intervention time

    20 minutes

    Tools required

    Screwdrivers

    Extraction tool

    Figure 7-4 xCCM-U-4E1 configuration front panel

    Figure 7-5 xCCM-U-GE configuration front panel

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the xCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-14 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • DANGER

    Laser hazard

    This equipment operates with invisible laser radiation. Laser radiation can cause

    considerable injuries to the eyes.

    Never look into the end of an exposed fiber or into an open optical connector when the

    optical source is switched on. Always observe the laser warning instructions.

    NOTICE

    ESD hazard

    Electronic components can be destroyed by electrostatic discharge (ESD).

    Hold circuit packs only at the edges or on the insertion and removal facilities.

    Always observe the general ESD instructions.

    NOTICE

    Service-disruption hazard

    Following the procedure below will result in a loss of service.

    Procedure

    ...................................................................................................................................................................................................

    1 Important! There will be a loss of service on the Remote Radio device(s) associated

    with the xCCM-U being replaced.

    Lock all the objects associated with the Remote Radio devices connected to the faulty

    xCCM-U at the OMC by Set Administrative State.

    For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User

    Guide, NN-20500-032.

    ...................................................................................................................................................................................................

    2 Power down the 9326 d2U V2.

    To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).

    ...................................................................................................................................................................................................

    3 Undo and remove the lower hook (if present).

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the xCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-15

  • ...................................................................................................................................................................................................

    4 Loosen the two screws on the defective xCCM-U front panel.

    ...................................................................................................................................................................................................

    5 Unplug the xCCM-U from its RBP connectors using the extraction tool.

    ...................................................................................................................................................................................................

    6 Disconnect the GPS cable (connector labeled GPS) from the xCCM-U front panel if

    used.

    ...................................................................................................................................................................................................

    7 Disconnect the optical fiber(s) and remove the SFP transceiver(s) (connector(s) labeled

    OPTIC) from the xCCM-U front panel.

    ...................................................................................................................................................................................................

    8 Disconnect the digital cable (connector labeled "ALARM") from the xCCM-U front

    panel.

    ...................................................................................................................................................................................................

    9 Disconnect the TIL cable (labeled PORT 1) from the xCCM-U front panel.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the xCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-16 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • ...................................................................................................................................................................................................

    10

    If... Then...

    The xCCM-U hardware configuration is

    xCCM-U-4E1

    Disconnect the two E1/T1 connectors (labeled

    PCM E1/T1 and MDA) from the

    xCCM-U front panel.

    If the hybrid Iub interface is implemented,

    disconnect the Ethernet connector (labeled

    PORT 2).

    The xCCM-U hardware configuration is

    xCCM-U-GE

    Disconnect the Gigabit Ethernet cable(s) and

    remove the SFP transceiver(s) (labeled

    MDA) from the xCCM-U front panel.

    ...................................................................................................................................................................................................

    11 Extract the defective xCCM-U using the extraction tool.

    ...................................................................................................................................................................................................

    12 Insert the new xCCM-U into the slot guides without plugging it on the RBP.

    ...................................................................................................................................................................................................

    13 Reconnect the GPS cable (connector labeled GPS) on the xCCM-U front panel if used.

    ...................................................................................................................................................................................................

    14 Reinsert the SFP transceiver(s) (connector(s) labeled OPTIC) through the xCCM-U

    front panel.

    ...................................................................................................................................................................................................

    15 Important! In case of an xCCM-U equipped with MM SFP transceivers, when

    reconnecting the optical fibers on the xCCM-U front panel, put the LC connectors

    (L/R) in the same sense as they were before the intervention.

    Reconnect the optical fiber(s) (connector(s) labeled OPTIC) on the xCCM-U front

    panel.

    ...................................................................................................................................................................................................

    16 Reconnect the digital cable (connector labeled "ALARM") on the xCCM-U front panel.

    ...................................................................................................................................................................................................

    17 Reconnect the TIL cable (labeled PORT 1) on the xCCM-U front panel.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the xCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-17

  • ...................................................................................................................................................................................................

    18

    If... Then...

    The xCCM-U hardware configuration is

    xCCM-U-GE

    Reinsert the SFP transceiver(s) (connector(s)

    labeled MDA) through the xCCM-U front

    panel.

    Reconnect the Gigabit Ethernet cable(s)

    (labeled MDA) on the xCCM-U front panel.

    ...................................................................................................................................................................................................

    19 Insert completely the new xCCM-U into the 9326 d2U V2 rack by plugging it into its

    RBP connectors.

    ...................................................................................................................................................................................................

    20 Tighten the two screws on the xCCM-U front panel.

    ...................................................................................................................................................................................................

    21 Put the hook back in place and secure it.

    ...................................................................................................................................................................................................

    22 Power up the 9326 d2U V2.

    To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)

    ...................................................................................................................................................................................................

    23

    If... Then...

    The xCCM-U hardware configuration is

    xCCM-U-4E1

    Reconnect the two E1/T1 connectors (labeled

    PCM E1/T1 and MDA) on the xCCM-U

    front panel.

    If the hybrid Iub interface is implemented,

    reconnect the Ethernet connector (labeled

    PORT 2).

    ...................................................................................................................................................................................................

    24 Unlock from the OMC the objects previously locked through step 1.

    ...................................................................................................................................................................................................

    25 Check the state of the LEDs and display:

    The i/xCEM(s)-U and xCCM-U corporate LEDs should turn on, then take the

    following state:

    red LED OFF and green LED ON

    The green PCM LEDs should be ON.

    The green MDALEDs should be ON.

    The green/amber SYNC LEDs should indicate the PCM/MDA synchronization.

    9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the xCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    7-18 Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    NN-20500-204

    Issue 4.05 May 2010

  • 9326 d2U V2 corrective maintenance procedures

    Replacing the digital shelf equipment

    Replacing the xCCM-U

    ....................................................................................................................................................................................................................................

    ....................................................................................................................................................................................................................................

    NN-20500-204

    Issue 4.05 May 2010

    Alcatel-Lucent Proprietary

    Use pursuant to applicable agreements

    7-19

    E N D O F S T E