Title page
Alcatel-Lucent 9326
digital 2U Node B V2 | V7.1
Maintenance Guide
NN-20500-204
ISSUE 4.05
MAY 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Use pursuant to applicable agreements
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright 2010 Alcatel-Lucent. All rights reserved.
Contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside
Alcatel-Lucent without its written authorization.
Not to be used or disclosed except in accordance with applicable agreements.
Use pursuant to applicable agreements
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
Contents
About this document
Purpose ............................................................................................................................................................................................. ixix
Reason for revision ...................................................................................................................................................................... ixix
New in this release ....................................................................................................................................................................... ixix
Intended audience ......................................................................................................................................................................... ixix
Supported systems ........................................................................................................................................................................ ixix
How to use this document ........................................................................................................................................................... xx
Safety information ......................................................................................................................................................................... xx
Prerequisites ..................................................................................................................................................................................... xx
Conventions used ........................................................................................................................................................................... xx
Related information ....................................................................................................................................................................... xx
Document support ........................................................................................................................................................................ xixi
Technical support .......................................................................................................................................................................... xixi
How to order ................................................................................................................................................................................... xixi
How to comment ........................................................................................................................................................................... xixi
1 Roadmap to Distributed Base Stations documentation
Overview ....................................................................................................................................................................................... 1-11-1
Roadmap to Distributed Base Stations documentation ................................................................................................ 1-21-2
2 Safety statements
Overview ....................................................................................................................................................................................... 2-12-1
Structure of safety statements ................................................................................................................................................ 2-22-2
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
iii
3 Corrective maintenance activity
Overview ....................................................................................................................................................................................... 3-13-1
Corrective maintenance activity ........................................................................................................................................... 3-23-2
4 9326 d2U V2 introduction
Overview ....................................................................................................................................................................................... 4-14-1
9326 d2U V2 introduction ...................................................................................................................................................... 4-24-2
5 9326 d2U V2 hardware presentation
Overview ....................................................................................................................................................................................... 5-15-1
9326 d2U V2 hardware presentation .................................................................................................................................. 5-25-2
6 9326 d2U V2 power up and power down procedures
Overview ....................................................................................................................................................................................... 6-16-1
Powering up a 9326 d2U V2 ................................................................................................................................................. 6-26-2
Powering down a 9326 d2U V2 ........................................................................................................................................... 6-36-3
7 9326 d2U V2 corrective maintenance procedures
Overview ....................................................................................................................................................................................... 7-17-1
Replacing the digital shelf equipment
Overview ....................................................................................................................................................................................... 7-27-2
Replacing an iCEM-U .............................................................................................................................................................. 7-37-3
Replacing an xCEM-U ............................................................................................................................................................. 7-67-6
Replacing the iCCM-U ............................................................................................................................................................ 7-97-9
Replacing the xCCM-U ........................................................................................................................................................ 7-147-14
Replacing an optical transceiver ........................................................................................................................................ 7-207-20
Replacing the fans rack (48V) ............................................................................................................................................ 7-237-23
Replacing the pre-cabled 9326 d2U V2 rack ................................................................................................................ 7-287-28
Replacing the optional equipment
Overview .................................................................................................................................................................................... 7-387-38
Replacing the External Alarm module ............................................................................................................................. 7-397-39
Replacing the LPPCM module ........................................................................................................................................... 7-417-41
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
iv Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
A Product conformance statements
Overview ...................................................................................................................................................................................... A-1A-1
European regulatory requirement compliance ............................................................................................................... A-2A-2
North American regulatory requirement compliance .................................................................................................. A-4A-4
Compliances for other regions/countries ......................................................................................................................... A-7A-7
Operating conditions ............................................................................................................................................................... A-8A-8
Cable specifications ................................................................................................................................................................. A-9A-9
Product labeling ...................................................................................................................................................................... A-10A-10
Contents
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
v
List of figures
1-1 Roadmap to Distributed Base Stations documentation ................................................................................ 1-31-3
4-1 Outside view of the 9326 d2U V2 ....................................................................................................................... 4-34-3
5-1 9326 d2U V2 front view (with iCCM-U) ......................................................................................................... 5-25-2
5-2 9326 d2U V2 front view (with xCCM-U) ........................................................................................................ 5-25-2
7-1 iCEM-U front panel .................................................................................................................................................. 7-37-3
7-2 xCEM-U front panel ................................................................................................................................................. 7-67-6
7-3 iCCM-U board front panel ..................................................................................................................................... 7-97-9
7-4 xCCM-U-4E1 configuration front panel ........................................................................................................ 7-147-14
7-5 xCCM-U-GE configuration front panel .......................................................................................................... 7-147-14
7-6 Location of optical connectors in the 9326 d2U V2 ................................................................................... 7-217-21
7-7 Inserting an SFP transceiver in the iCCM-U ................................................................................................ 7-227-22
7-8 9326 d2U V2 front view (with iCCM-U) ....................................................................................................... 7-237-23
7-9 9326 d2U V2 front view (with xCCM-U) ...................................................................................................... 7-237-23
7-10 Extracting the fans rack ........................................................................................................................................ 7-257-25
7-11 Fans rack .................................................................................................................................................................... 7-257-25
7-12 9326 d2U V2 front view (with iCCM-U) ....................................................................................................... 7-287-28
7-13 9326 d2U V2 front view (with xCCM-U) ...................................................................................................... 7-287-28
7-14 Location of the management sticker ................................................................................................................ 7-307-30
7-15 Front panel of the External Alarm module .................................................................................................... 7-397-39
7-16 LPPCM module front panel ................................................................................................................................ 7-417-41
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
vii
About this documentAbout this document
Purpose
The purpose of this document is to describe corrective maintenance procedures applicable
to the 9326 d2U V2 rack.
Reason for revision
The reissue reasons are:
Issue number Issue date Reason for reissue
4.05 May 2010 Standard issue
4.04 March 2010 Preliminary issue
4.03 February 2010 Preliminary issue
4.02 November 2009 Preliminary issue
4.01 October 2009 Draft issue
New in this release
New features:
74759 Gigabit Ethernet MDA for xCCM, see Replacing the xCCM-U (p. 7-14)
Important! The availability of the features listed above on the hardware equipment
should be checked with your Alcatel-Lucent representative.
Other changes:
Reformat to comply with current documentation standards
Intended audience
The audience for this document is Operations and maintenance personnel and those who
want to know the principles of 9326 d2U V2 maintenance.
Supported systems
This document applies to Alcatel-Lucent W-CDMAV7.1 system release.
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
ix
How to use this document
No specific recommendation applies regarding the way readers should read this
document.
Safety information
For your safety, this document contains safety statements. Safety statements are given at
points where risks of damage to personnel, equipment, and operation may exist. Failure to
follow the directions in a safety statement may result in serious consequences.
Prerequisites
It is recommended that readers become familiar with the following documents:
Alcatel-Lucent 9326 digital 2U Node B V2 - Technical Description, NN-20500-203
Alcatel-Lucent 93xx Node B Commissioning and Fault Management User Manual:
TIL, NN-20500-019
Conventions used
Vocabulary conventions
For a list of terms used in this document, see Alcatel-Lucent W-CDMA System -
Terminology, NN-20500-002.
Typographical conventions
The following typographical conventions are used in this document:
Appearance Description
Italicized text Emphasized information
graphical user interface text Text that is displayed in a graphical user interface or
in a hardware label
Document reference, reference number Related document that is referenced in the document
Related information
For information on subjects related to the content of this document, refer to the
documents listed in the following table:
Refer to this document At this location For more information on
Alcatel-Lucent W-CDMA
System - Terminology,
NN-20500-002
http://support.alcatel-
lucent.com.
Terms used in Alcatel-Lucent
W-CDMA documents.
Alcatel-Lucent 9326 digital
2U Node B V2 - Technical
Description, NN-20500-203
http://support.alcatel-
lucent.com.
The Alcatel-Lucent 9326
digital 2U Node B V2:
Basic characteristics
Hardware description
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
x Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
Refer to this document At this location For more information on
Alcatel-Lucent 9353
Wireless Management
System - Node B Alarms
Reference Guide for 9311,
9312, 9322, 9326, 9332
Node B, NN-20500-018P1
http://support.alcatel-
lucent.com.
Alarm descriptions and
maintenance actions required
for Alcatel-Lucent Node Bs.
Alcatel-Lucent 9353
Wireless Management
System - User Guide,
NN-20500-032
http://support.alcatel-
lucent.com.
How to perform commands
available in the 9353 Wireless
Management System (WMS)
Graphical User Interface
(GUI).
Alcatel-Lucent 93xx Node B
Commissioning and Fault
Management User Manual:
TIL, NN-20500-019
http://support.alcatel-
lucent.com.
How to perform the Node B
installation, commissioning
and maintenance tasks using
the Node B TIL (Terminal for
Local Installation) tool.
Alcatel-Lucent W-CDMA
System Safety Guide,
401-382-880
http://support.alcatel-
lucent.com.
Safety guidelines and the
catalog of hazard statements
that appear in the
Alcatel-Lucent W-CDMA
customer documents.
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
1-888-582-3688 (for the United States)
1-317-377-8618 (for all other countries)
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.
alcatel-lucent.com/comments/enus/) or e-mail your comments to the Comments Hotline
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
xi
1 1Roadmap to Distributed
Base Stations
documentation
Overview
Purpose
This chapter provides the roadmap for Distributed Base Stations documentation.
Contents
Roadmap to Distributed Base Stations documentation 1-2
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
1-1
Roadmap to Distributed Base Stations documentation
The following figure shows where the current document stands within the W-CDMA
customer documentation.
For a global view of the W-CDMA customer documentation, see the Roadmap chapter in:
Alcatel-Lucent W-CDMA System - Document Collection Overview, NN-20500-050
Alcatel-Lucent W-CDMA System - Access Network Elements Overview,
NN-20500-233
Roadmap to Distributed Base Stations documentation Roadmap to Distributed Base Stations documentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
1-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
Figure 1-1 Roadmap to Distributed Base Stations documentation
Roadmap to Distributed Base Stations documentation Roadmap to Distributed Base Stations documentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
1-3
2 2Safety statements
Overview
Purpose
This chapter provides information on the structure of safety statements which may arise
in the course of your work.
Contents
Structure of safety statements 2-2
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
2-1
Structure of safety statements
Overview
Safety statements describe the safety risks relevant while performing tasks on
Alcatel-Lucent products during deployment and/or use. Failure to avoid the hazards may
have serious consequences.
General structure
Safety statements include the following structural elements:
Item Structure element Purpose
1 Safety alert symbol Indicates the potential for personal injury
(optional)
2 Safety symbol Indicates hazard type (optional)
3 Signal word Indicates the severity of the hazard
4 Hazard type Describes the source of the risk of damage or
injury
5 Safety message Consequences if protective measures fail
6 Avoidance message Protective measures to take to avoid the hazard
7 Identifier The reference ID of the safety statement
(optional)
Signal words
The signal words identify the hazard severity levels as follows:
Signal word Meaning
DANGER Indicates an extremely hazardous situation which, if not avoided, will
result in death or serious injury.
Lifting this equipment by yourself can result in injurydue to the size and weight of the equipment.Always use three people or a lifting device to transportand position this equipment. [ABC123]
CAUTION
Lifting hazard
B C D
E F
G
H
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
2-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
Signal word Meaning
WARNING Indicates a hazardous situation which, if not avoided, could result in
death or serious injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in
minor or moderate injury.
NOTICE Indicates a hazardous situation not related to personal injury.
Safety statements Structure of safety statements
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
2-3
3 3Corrective maintenance
activity
Overview
Purpose
This chapter describes the corrective maintenance activity applicable to the 9326 d2U V2
rack.
Contents
Corrective maintenance activity 3-2
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
3-1
Corrective maintenance activity
Corrective maintenance
The network maintenance is based on the supervision of the network, by using the OAM
graphical interface. For more information, refer to Alcatel-Lucent 9353 Wireless
Management System - User Guide, NN-20500-032.
It is also based on the identification and replacement of faulty items of equipment, using
the alarms.
The process is divided into the following two steps:
Locating and identifying the faulty items of equipment, by using the information
provided in Alcatel-Lucent 9353 Wireless Management System - Node B Alarms
Reference Guide for 9311, 9312, 9322, 9326, 9332 Node B, NN-20500-018P1
Replacing the faulty items of equipment, by using the replacement procedures given
in this document
Note: The iModules replacement procedures described in this guide are based on the
following assumptions:
Your 9326 d2U V2 is equipped with the following digital modules:
One iCCM-U upgraded with the specific adapter board and front panel (iCCM-U
V2)
One xCEM-U (mandatory) and possibly up to two additional xCEMs-U
Possibly up to two iCEMs-U upgraded with the specific adapter boards and front
panels (iCEMs-U V2)
As spare parts, you ordered iCEMs-U V2 and iCCMs-U V2 modules (order codes:
3JR08057AA and 3JR08056AA).
Replacing the digital shelf equipment
Procedure Order Code Impact on service
Replacing an iCEM-U
(p. 7-3)
3JR08057AA Loss of capacity or loss of service
(depending on the number of CEMs in
the digital shelf)
Replacing an xCEM-U
(p. 7-6)
300986049 Loss of capacity or loss of service
(depending on the number of CEMs in
the digital shelf)
Replacing the iCCM-U
(p. 7-9)
3JR08056AA Loss of service on the Remote Radio
device(s) associated with the iCCM-U
being replaced
Replacing the xCCM-U
(p. 7-14)
3JR20038AA Loss of service on the Remote Radio
device(s) associated with the xCCM-U
being replaced
Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
Procedure Order Code Impact on service
Replacing an optical
transceiver (p. 7-20)
Single-Mode (SM):
NTU850HA
Loss of service on the Remote Radio
device associated with the optical
transceiver being replacedMulti-Mode (MM):
NTU850HM
Replacing the fans rack
(48V) (p. 7-23)
3JR08021AA Service interruption
Replacing the pre-cabled
9326 d2U V2 rack
(p. 7-28)
3JR08067AA Service interruption
Replacing the optional equipment
Procedure Order Code Impact on service
Replacing the LPPCM
module (p. 7-41)
NTU870GM Service interruption
Replacing the External
Alarm module (p. 7-39)
NTU870GA None
Description of a replacement procedure
A replacement procedure is divided into the following parts:
The title
The main body with the following information:
The intervention time
The tools required
The impact of the procedure, if necessary
The step-by-step actions of the procedure
One or more figures are provided to help you execute the actions. They show the FRU
schematically and its location in the cabinet.
Intervention restrictions
There may be a lapse of time between the identification of the alarm at the Access OAM
Graphic User Interface (GUI) and the time you arrive at the site.
You must be synchronized with the access network controller or system administrator (by
telephone) before an on-site intervention, in the following cases:
Isolating procedures
Completion of an on-site intervention
Return to service procedure
Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
3-3
General personnel safety instructions
The personnel must obey the safety instructions specific to the installation site:
Rules concerning the premises (see instructions posted on site or in the building)
Rules linked to general personnel safety instructions
The personnel working on the cabinet must be authorized to work according to security
standards.
Equipment safety instructions
The 9326 d2U V2 normally operates when the external temperature is between 5C and
+65C.
Corrective maintenance activity Corrective maintenance activity
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
3-4 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
4 49326 d2U V2 introduction
Overview
Purpose
This chapter introduces the 9326 d2U V2.
Contents
9326 d2U V2 introduction 4-2
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
4-1
9326 d2U V2 introduction
The 9326 d2U V2 is the enhanced 9326 d2U rack supporting xModules (xCEM-U,
xCCM-U). It is designed to be connected to one of the following products via optical
fiber links:
RRH60-21
RRH40-AWS
RRH40-21
RRH40-08
RRH40-19
RRH20-21
9332 rCompact
The iModules (iCEM-U, iCCM-U) can be plugged in this 9326 d2U V2 rack, using
specific adapter boards and front panels.
xCEM-U and iCEM-U modules can be mixed inside the 9326 d2U V2 rack. The 9326
d2U V2 rack is factory-equipped with one xCCM-U or one iCCM-U (in slot 1), one
xCEM-U (in slot 2) and two fillers. Depending on the capacity requirements, the 9326
d2U V2 rack can host two xCEMs-U, two iCEMs-U, or one xCEM-U and one iCEM-U
in place of the two fillers (slot 3 and slot 4).
The Alcatel-Lucent Remote Radio solution improves flexibility for deploying mobile
broadband Node Bs in space-constrained locations. It is particularly suited to
macro-cellular applications in dense areas, where site acquisition is difficult, and on sites
where installation constraints prevent the use of legacy Node Bs.
Compared to legacy Node B site deployment, the Remote Radio solution provides the
following benefits:
Reduced volume, weight, footprint, acoustic noise, and power consumption
Reduced cost of feeder paths from the Node B to the antenna
Increased RF power per carrier at the antenna feeder
Reduced radio loss with use of the remote RF block concept, which eliminates the
distance between the radio amplifier and the antenna
The Remote Radio solution provides for the UMTS system:
The means of communication between a User Equipment (UE) and a network using
Transport Channels
Physical layer channels, which are necessary to synchronize the downlink and
perform cell selection/reselection and handover preparation
Measurement information to the RNC for radio resource management (handover,
power control)
The 9326 d2U V2 provides up to eight E1/T1 with Inversion Multiplexing ATM (IMA) or
Drop-and-Insert capability (fractional E1/T1). The 9326 d2U V2 also supports
multi-PCM without IMA.
9326 d2U V2 introduction 9326 d2U V2 introduction
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
4-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
The 9326 d2U V2 delivers high UMTS radio performances and supports the enhanced
High Speed Downlink Packet Access (HSDPA) and High Speed Uplink Packet Access
(HSUPA) solutions through easy software upgrade.
The 9326 d2U V2 is compliant with the Common Public Radio Interface (CPRI).
9326 d2U V2 enclosure
The 9326 d2U V2 provides the operators with a suited solution whatever the site
constraints.
The 9326 d2U V2 can be installed in a standalone indoor mode or in an existing indoor or
outdoor Alcatel-Lucent 9100 Multi-Standard Base Station cabinet for multi-standard
configuration.
Moreover, the 9326 d2U V2 can be integrated in a small or a medium Power Supply Unit
(PSU) outdoor cabinet.
The following figure shows an outside view of the 9326 d2U V2.
Figure 4-1 Outside view of the 9326 d2U V2
9326 d2U V2 introduction 9326 d2U V2 introduction
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
4-3
5 59326 d2U V2 hardware
presentation
Overview
Purpose
This chapter describes the hardware of the 9326 d2U V2 rack.
Contents
9326 d2U V2 hardware presentation 5-2
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
5-1
9326 d2U V2 hardware presentation
The 9326 d2U V2 is built around the following components:
Amechanical enclosure (including two fans), compatible with standard 19-inch rack
installation
A digital shelf including the digital modules and the associated digital backplane
A commissioning module located on the right hand side of the digital shelf
The following figure shows a front view of the 9326 d2U V2 equipped with iCCM-U.
The following figure shows a front view of the 9326 d2U V2 equipped with xCCM-U.
Figure 5-1 9326 d2U V2 front view (with iCCM-U)
Figure 5-2 9326 d2U V2 front view (with xCCM-U)
9326 d2U V2 hardware presentation 9326 d2U V2 hardware presentation
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
5-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
6 69326 d2U V2 power up
and power down
procedures
Overview
Purpose
This chapter describes how to power up and power down the 9326 d2U V2.
Contents
Powering up a 9326 d2U V2 6-2
Powering down a 9326 d2U V2 6-3
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
6-1
Powering up a 9326 d2U V2
Perform the following procedure to power up a 9326 d2U V2.
Initial check
On the RUC module, check that the power switch is in the "O" position.
Procedure
...................................................................................................................................................................................................
1 At the operator DC power supply, put the site circuit breaker of the 9326 d2U V2 in the
"ON" position.
...................................................................................................................................................................................................
2 On the RUC module, put the power switch in the "1" position.
...................................................................................................................................................................................................
3 Check that the fans are starting up.
...................................................................................................................................................................................................
4 On the iCCM-U/xCCM-U and on each iCEM-U/xCEM-U, check that:
The green LED is ON.
The red LED is OFF.
9326 d2U V2 power up and power down procedures Powering up a 9326 d2U V2
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
6-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
E N D O F S T E P S...................................................................................................................................................................................................
Powering down a 9326 d2U V2
Perform the following procedure to power down a 9326 d2U V2.
Procedure
...................................................................................................................................................................................................
1 Preliminary operation: make sure that the btsSiteManager object is "locked".
...................................................................................................................................................................................................
2 On the RUC module, put the power switch in the "O" position.
...................................................................................................................................................................................................
3 Check that the green or red LED on the iCCM-U/xCCM-U and on each
iCEM-U/xCEM-U is OFF.
...................................................................................................................................................................................................
4 Check that the fans are stopping down.
...................................................................................................................................................................................................
5 At the operator DC power supply, put the site circuit breaker of the 9326 d2U V2 in the
"OFF" position.
9326 d2U V2 power up and power down procedures Powering down a 9326 d2U V2
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
6-3
E N D O F S T E P S...................................................................................................................................................................................................
7 79326 d2U V2 corrective
maintenance procedures
Overview
Purpose
This chapter contains the replacement procedures applicable to the 9326 d2U V2 rack.
Note:
1. For detailed information on PSU maintenance, refer to the documentation
provided within the PSU cabinet.
2. For detailed information on Alcatel-Lucent 9100 Multi-Standard Base Station
maintenance, refer to the documentation related to the Alcatel-Lucent 9100
Multi-Standard Base Station cabinets.
Contents
Replacing the digital shelf equipment 7-2
Replacing an iCEM-U 7-3
Replacing an xCEM-U 7-6
Replacing the iCCM-U 7-9
Replacing the xCCM-U 7-14
Replacing an optical transceiver 7-20
Replacing the fans rack (48V) 7-23
Replacing the pre-cabled 9326 d2U V2 rack 7-28
Replacing the optional equipment 7-38
Replacing the External Alarm module 7-39
Replacing the LPPCM module 7-41
...................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-1
Replacing the digital shelf equipment
Overview
Purpose
This section presents the replacement procedures applicable to the digital shelf.
Those replacement procedures concern the following modules:
integrated Channel Element Module-U (iCEM-U) or eXtended Channel Element
Module-U (xCEM-U)
integrated Core Controller Module-U (iCCM-U) or eXtended Core Controller
Module-U (xCCM-U)
Optical transceiver
Fans rack (48V)
Pre-cabled 9326 d2U V2 rack
Contents
Replacing an iCEM-U 7-3
Replacing an xCEM-U 7-6
Replacing the iCCM-U 7-9
Replacing the xCCM-U 7-14
Replacing an optical transceiver 7-20
Replacing the fans rack (48V) 7-23
Replacing the pre-cabled 9326 d2U V2 rack 7-28
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Overview
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-2 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
Replacing an iCEM-U
Carry out the following procedure to replace an iCEM-U.
Intervention time
15 minutes
Tools required
Screwdrivers
Extraction tool
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of capacity or a loss of service
(depending on the number of CEMs housed in the 9326 d2U V2 rack).
Procedure
...................................................................................................................................................................................................
1 Locate the faulty iCEM-U in the 9326 d2U V2 rack: its red triangular LED is ON.
Figure 7-1 iCEM-U front panel
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing an iCEM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-3
...................................................................................................................................................................................................
2 Lock the faulty cem object at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................
3 Undo and remove the upper hook (if present and if the defective iCEM-U is in slot 4).
...................................................................................................................................................................................................
4 Loosen the two screws on the defective iCEM-U front panel.
...................................................................................................................................................................................................
5 Remove the defective iCEM-U using the extraction tool.
...................................................................................................................................................................................................
6 If you are to replace the defective iCEM-U with a xCEM-U, go to step 6 of the procedure
Replacing an xCEM-U (p. 7-6).
If you are to replace the defective iCEM-U with a new iCEM-U, check the release of the
new iCEM-U.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing an iCEM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-4 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
...................................................................................................................................................................................................
7 Insert the new iCEM-U into the 9326 d2U V2 rack, in the same slot as the defective
iCEM-U.
...................................................................................................................................................................................................
8 Tighten the two screws on the iCEM-U front panel.
...................................................................................................................................................................................................
9 Put the hook back in place and secure it.
...................................................................................................................................................................................................
10 From the OMC, unlock the cem object previously locked on step 2.
...................................................................................................................................................................................................
11 Check the state of the LEDs. They should go on, then take the following state:
red triangular LED OFF and green rectangular LED ON.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing an iCEM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-5
E N D O F S T E P S...................................................................................................................................................................................................
Replacing an xCEM-U
Carry out the following procedure to replace an xCEM-U.
Intervention time
Ten minutes
Tools required
Screwdriver
Extraction tool
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of capacity or a loss of service
(depending on the number of CEMs housed in the 9326 d2U V2 rack).
Procedure
...................................................................................................................................................................................................
1 Locate the faulty xCEM-U in the 9326 d2U V2 rack: its red LED is ON.
Figure 7-2 xCEM-U front panel
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing an xCEM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-6 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
...................................................................................................................................................................................................
2 Lock the faulty cem object at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................
3 Undo and remove the upper hook (if present and if the defective xCEM-U is in slot 4).
...................................................................................................................................................................................................
4 Loosen the two screws on the xCEM-U front panel.
...................................................................................................................................................................................................
5 Remove the defective xCEM-U using the extraction tool.
...................................................................................................................................................................................................
6 Check the release of the new xCEM-U.
...................................................................................................................................................................................................
7 Insert the new xCEM-U into the 9326 d2U V2 rack, in the same slot as the defective
xCEM-U.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing an xCEM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-7
...................................................................................................................................................................................................
8 Tighten the two screws on the xCEM-U front panel.
...................................................................................................................................................................................................
9 Put the hook back in place and secure it.
...................................................................................................................................................................................................
10 From the OMC, unlock the cem object previously locked on step 2.
...................................................................................................................................................................................................
11 Check the state of the LEDs. They should go on, then take the following state:
red triangular LED OFF and green rectangular LED ON.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing an xCEM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-8 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
E N D O F S T E P S...................................................................................................................................................................................................
Replacing the iCCM-U
Carry out the following procedure to replace the iCCM-U.
Intervention time
20 minutes
Tools required
Screwdrivers
Extraction tool
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
Figure 7-3 iCCM-U board front panel
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the iCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-9
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Important! The spare iCCM-U software load must be UA05.1.2, otherwise the 9326
d2U V2 can not start.
Important! There will be a loss of service on the Remote Radio device(s) associated
with the iCCM-U being replaced.
Procedure
...................................................................................................................................................................................................
1 Lock all the objects associated with the Remote Radio devices connected to the faulty
iCCM-U at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................
2 Power down the 9326 d2U V2.
To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................
3 Undo and remove the lower hook (if present).
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the iCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-10 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
...................................................................................................................................................................................................
4 Loosen the two screws on the defective iCCM-U front panel.
...................................................................................................................................................................................................
5 Unplug the iCCM-U from its RBP connectors using the extraction tool.
...................................................................................................................................................................................................
6 Disconnect the optical fiber(s) from the iCCM-U front panel.
...................................................................................................................................................................................................
7 Remove the SFP transceiver(s) from the iCCM-U front panel.
...................................................................................................................................................................................................
8 Disconnect the digital cable (connector labeled "ALARM") from the iCCM-U front
panel.
...................................................................................................................................................................................................
9 Disconnect the E1/T1 connector (PCM link) from the iCCM-U front panel.
...................................................................................................................................................................................................
10 Extract the defective iCCM-U using the extraction tool.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the iCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-11
...................................................................................................................................................................................................
11 Insert the new iCCM-U into the slot guides without plugging it on the RBP.
...................................................................................................................................................................................................
12 Reinsert the SFP transceiver(s) through the iCCM-U front panel.
...................................................................................................................................................................................................
13 Important! In case of an iCCM-U equipped with MM SFP transceivers, when
reconnecting the optical fibers on the iCCM-U front panel, put the LC connectors
(L/R) in the same sense as they were before the intervention.
Reconnect the optical fiber(s) on the iCCM-U front panel.
...................................................................................................................................................................................................
14 Reconnect the digital cable on the iCCM-U front panel.
...................................................................................................................................................................................................
15 Insert completely the new iCCM-U into the 9326 d2U V2 rack by plugging it into its RBP
connectors.
...................................................................................................................................................................................................
16 Tighten the two screws on the iCCM-U front panel.
...................................................................................................................................................................................................
17 Put the hook back in place and secure it.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the iCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-12 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
...................................................................................................................................................................................................
18 Important! If the iCCM-U software load is not UA05.1.2, the 9326 d2U V2 can not
start.
Power up the 9326 d2U V2.
To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)
...................................................................................................................................................................................................
19 Reconnect the PCM E1/T1 cable on the iCCM-U front panel.
...................................................................................................................................................................................................
20 Unlock from the OMC the objects previously locked through step 1.
...................................................................................................................................................................................................
21 Check the state of the LEDs and display:
The i/xCEM(s)-U and iCCM-U corporate LEDs should turn on, then take the
following state:
red LED OFF and green LED ON.
The green PCM LEDs should be ON.
The display should indicate the PCM synchronization.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the iCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-13
E N D O F S T E P S...................................................................................................................................................................................................
Replacing the xCCM-U
Carry out the following procedure to replace the xCCM-U.
Intervention time
20 minutes
Tools required
Screwdrivers
Extraction tool
Figure 7-4 xCCM-U-4E1 configuration front panel
Figure 7-5 xCCM-U-GE configuration front panel
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the xCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-14 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
DANGER
Laser hazard
This equipment operates with invisible laser radiation. Laser radiation can cause
considerable injuries to the eyes.
Never look into the end of an exposed fiber or into an open optical connector when the
optical source is switched on. Always observe the laser warning instructions.
NOTICE
ESD hazard
Electronic components can be destroyed by electrostatic discharge (ESD).
Hold circuit packs only at the edges or on the insertion and removal facilities.
Always observe the general ESD instructions.
NOTICE
Service-disruption hazard
Following the procedure below will result in a loss of service.
Procedure
...................................................................................................................................................................................................
1 Important! There will be a loss of service on the Remote Radio device(s) associated
with the xCCM-U being replaced.
Lock all the objects associated with the Remote Radio devices connected to the faulty
xCCM-U at the OMC by Set Administrative State.
For more information, refer to Alcatel-Lucent 9353 Wireless Management System - User
Guide, NN-20500-032.
...................................................................................................................................................................................................
2 Power down the 9326 d2U V2.
To do this, follow the procedure Powering down a 9326 d2U V2 (p. 6-3).
...................................................................................................................................................................................................
3 Undo and remove the lower hook (if present).
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the xCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-15
...................................................................................................................................................................................................
4 Loosen the two screws on the defective xCCM-U front panel.
...................................................................................................................................................................................................
5 Unplug the xCCM-U from its RBP connectors using the extraction tool.
...................................................................................................................................................................................................
6 Disconnect the GPS cable (connector labeled GPS) from the xCCM-U front panel if
used.
...................................................................................................................................................................................................
7 Disconnect the optical fiber(s) and remove the SFP transceiver(s) (connector(s) labeled
OPTIC) from the xCCM-U front panel.
...................................................................................................................................................................................................
8 Disconnect the digital cable (connector labeled "ALARM") from the xCCM-U front
panel.
...................................................................................................................................................................................................
9 Disconnect the TIL cable (labeled PORT 1) from the xCCM-U front panel.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the xCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-16 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
...................................................................................................................................................................................................
10
If... Then...
The xCCM-U hardware configuration is
xCCM-U-4E1
Disconnect the two E1/T1 connectors (labeled
PCM E1/T1 and MDA) from the
xCCM-U front panel.
If the hybrid Iub interface is implemented,
disconnect the Ethernet connector (labeled
PORT 2).
The xCCM-U hardware configuration is
xCCM-U-GE
Disconnect the Gigabit Ethernet cable(s) and
remove the SFP transceiver(s) (labeled
MDA) from the xCCM-U front panel.
...................................................................................................................................................................................................
11 Extract the defective xCCM-U using the extraction tool.
...................................................................................................................................................................................................
12 Insert the new xCCM-U into the slot guides without plugging it on the RBP.
...................................................................................................................................................................................................
13 Reconnect the GPS cable (connector labeled GPS) on the xCCM-U front panel if used.
...................................................................................................................................................................................................
14 Reinsert the SFP transceiver(s) (connector(s) labeled OPTIC) through the xCCM-U
front panel.
...................................................................................................................................................................................................
15 Important! In case of an xCCM-U equipped with MM SFP transceivers, when
reconnecting the optical fibers on the xCCM-U front panel, put the LC connectors
(L/R) in the same sense as they were before the intervention.
Reconnect the optical fiber(s) (connector(s) labeled OPTIC) on the xCCM-U front
panel.
...................................................................................................................................................................................................
16 Reconnect the digital cable (connector labeled "ALARM") on the xCCM-U front panel.
...................................................................................................................................................................................................
17 Reconnect the TIL cable (labeled PORT 1) on the xCCM-U front panel.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the xCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-17
...................................................................................................................................................................................................
18
If... Then...
The xCCM-U hardware configuration is
xCCM-U-GE
Reinsert the SFP transceiver(s) (connector(s)
labeled MDA) through the xCCM-U front
panel.
Reconnect the Gigabit Ethernet cable(s)
(labeled MDA) on the xCCM-U front panel.
...................................................................................................................................................................................................
19 Insert completely the new xCCM-U into the 9326 d2U V2 rack by plugging it into its
RBP connectors.
...................................................................................................................................................................................................
20 Tighten the two screws on the xCCM-U front panel.
...................................................................................................................................................................................................
21 Put the hook back in place and secure it.
...................................................................................................................................................................................................
22 Power up the 9326 d2U V2.
To do this, follow the procedure Powering up a 9326 d2U V2 (p. 6-2)
...................................................................................................................................................................................................
23
If... Then...
The xCCM-U hardware configuration is
xCCM-U-4E1
Reconnect the two E1/T1 connectors (labeled
PCM E1/T1 and MDA) on the xCCM-U
front panel.
If the hybrid Iub interface is implemented,
reconnect the Ethernet connector (labeled
PORT 2).
...................................................................................................................................................................................................
24 Unlock from the OMC the objects previously locked through step 1.
...................................................................................................................................................................................................
25 Check the state of the LEDs and display:
The i/xCEM(s)-U and xCCM-U corporate LEDs should turn on, then take the
following state:
red LED OFF and green LED ON
The green PCM LEDs should be ON.
The green MDALEDs should be ON.
The green/amber SYNC LEDs should indicate the PCM/MDA synchronization.
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the xCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
7-18 Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
NN-20500-204
Issue 4.05 May 2010
9326 d2U V2 corrective maintenance procedures
Replacing the digital shelf equipment
Replacing the xCCM-U
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
NN-20500-204
Issue 4.05 May 2010
Alcatel-Lucent Proprietary
Use pursuant to applicable agreements
7-19
E N D O F S T E