1
Alfa-Zeta Co. Ltd. ul. Starorudzka 6a 93-418 Łódź, POLAND tel. +48 42 689 12 00 tel. +48 42 689 12 01 tel. +48 42 689 12 02 fax: +48 42 689 12 03 [email protected] http://www.alfazeta.pl iFLIP Control software for flipdot displays The iFLIP system installed on a Windows PC micro-computer or all-in-one computer allows to create a master control unit which can control a flipdot sign. It is created for end customer and makes it possible to show static graphics or animated images on the sign. Flexibility of addressing and easiness of user interface makes this solution a dedicated one for shops, trade fair booths, receptions or any other place where a flip dot sign can be installed. No programming skills is needed to control a flipdot display. Main functions: ź combines series of static images or animations into animations suitable for transmission to a sign ź resamples source files to fit into resolution of a sign ź re-converts input files into 1-bit graphics to fit into color space of a sign ź built-in weekly schedulers ź allows to enable / disable individually each section of the project ź ź allows preview of a project before sending it into actual panels ź calculates duration of a project ź accepts .BMP, .JPG, .JPEG, .PNG, TIFF, .GIF, .GIF(animated) as input files setup section allows to configure physical addressing of individual panels ź shuffle, repeat or defined order of the frames. ź ź ź ź ź ź ź Hardware requirements: ź all - in - one which are well suited for space limited environments) a computer with the software must run continuously while the controlled sign is run - as a result it is strongly recommended to use a dedicated machine to avoid incompatibilities with other installed software ź PC computer(tested also on Intel NUC or PIPO X8 ź ź ź ź ź ź ź ź ź ź ź 2GB of free place on a HDD ź .NET 4.5 libraries version ź Intel i3 processor or better ź Windows 7 / 8 / 8.1 / 10 Ethernet port to connect to Ethernet - to - Rs485 converter (optional but recommended for high speed applications) 2 GB RAM www.flipdots.com

Alfa-Zeta Co. Ltd. iFLIP 93-418 Łódź, POLAND tel. …flipdots.alfazeta.nazwa.pl/wp-content/uploads/2016/12/...Alfa-Zeta Co. Ltd. ul. Starorudzka 6a 93-418 Łódź, POLAND tel. +48

  • Upload
    others

  • View
    15

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Alfa-Zeta Co. Ltd. iFLIP 93-418 Łódź, POLAND tel. …flipdots.alfazeta.nazwa.pl/wp-content/uploads/2016/12/...Alfa-Zeta Co. Ltd. ul. Starorudzka 6a 93-418 Łódź, POLAND tel. +48

Alfa-Zeta Co. Ltd.ul. Starorudzka 6a93-418 Łódź, POLAND

tel. +48 42 689 12 00tel. +48 42 689 12 01tel. +48 42 689 12 02fax: +48 42 689 12 03

[email protected]://www.alfazeta.pl

iFLIPControl software for flipdot displays

The iFLIP system installed on a Windows PC micro-computer or all-in-one computer allows to create a master control unit which can control a flipdot sign. It is created for end customer and makes it possible to show static graphics or animated images on the sign. Flexibility of addressing and easiness of user interface makes this solution a dedicated one for shops, trade fair booths, receptions or any other place where a flip dot sign can be installed. No programming skills is needed to control a flipdot display.

Main functions:

ź combines series of static images or animationsinto animations suitable for transmission to a sign

ź resamples source files to fit into resolution of a signź re-converts input files into 1-bit graphics to fit into

color space of a signź built-in weekly schedulersź allows to enable / disable individually each section of the projectź

ź allows preview of a project before sending it intoactual panels

ź calculates duration of a project

ź accepts .BMP, .JPG, .JPEG, .PNG, TIFF, .GIF,.GIF(animated) as input files

setup section allows to configure physical addressing of individual panels

ź shuffle, repeat or defined order of the frames.

ź

ź

ź

ź

ź

ź

ź

Hardware requirements:

ź

all - in - one which are well suited for space limited environments)a computer with the software must run continuously while the controlled sign is run - as a result it is strongly recommended to use a dedicated machine to avoid incompatibilities with other installed software

ź

PC computer(tested also on Intel NUC or PIPO X8ź

ź

ź

ź

ź

ź

ź

ź

ź

ź

ź 2GB of free place on a HDDź .NET 4.5 libraries versionź Intel i3 processor or better ź Windows 7 / 8 / 8.1 / 10 Ethernet port to connect to Ethernet - to - Rs485 converter (optional but recommended for high speed applications)

2 GB RAM

www.flipdots.com