Upload
arren-khan
View
213
Download
0
Embed Size (px)
Citation preview
The
info
rmat
ion
prov
ided
in th
is d
ocum
enta
tion
cont
ains
gen
eral
des
crip
tions
and
/or t
echn
ical
cha
ract
eris
tics
of th
e pe
rform
ance
of t
he p
rodu
cts
cont
aine
d he
rein
.Th
is d
ocum
enta
tion
is n
ot in
tend
ed a
s a
subs
titut
e fo
r and
is n
ot to
be
used
for d
eter
min
ing
suita
bilit
y or
relia
bilit
y of
thes
e pr
oduc
ts fo
r spe
cific
use
r app
licat
ions
.It
is th
e du
ty o
f any
suc
h us
er o
r int
egra
tor t
o pe
rform
the
appr
opria
te a
nd c
ompl
ete
risk
anal
ysis
, eva
luat
ion
and
test
ing
of th
e pr
oduc
ts w
ith re
spec
t to
the
rele
vant
spe
cific
app
licat
ion
or u
se th
ereo
f.N
eith
er S
chne
ider
Ele
ctric
Indu
strie
s SA
S no
r any
of i
ts a
ffilia
tes
or s
ubsi
diar
ies
shal
l be
resp
onsi
ble
or li
able
for m
isus
e of
the
info
rmat
ion
cont
aine
d he
rein
.
Jan 27, 20151
Product data sheetCharacteristics
ATV212HD45N4variable speed drive ATV212 - 45kW - 60hp -480V - 3ph - EMC - IP21
MainRange of product Altivar 212Product or componenttype
Variable speed drive
Device short name ATV212Product destination Asynchronous motorsProduct specific appli-cation
Pumps and fans in HVAC
Assembly style With heat sinkNetwork number ofphases
3 phases
Motor power kW 45 kWMotor power hp 60 hpPower supply voltage 380...480 V (- 15...10 %)Power supply voltagelimits
323...528 V
Supply frequency 50...60 Hz (- 5...5 %)Network frequency 47.5...63 HzEMC filter Class C2 EMC filter integratedLine current 65.9 A for 480 V
83.8 A for 380 V
ComplementaryApparent power 61.9 kVA for 380 VProspective line Isc 22 kAContinuous output current 94 A at 380/460 VMaximum transient current 103.4 A for 60 sSpeed drive output frequency 0.5...200 HzNominal switching frequency 8 kHzSwitching frequency 8...16 kHz with derating factor
6...16 kHz adjustableSpeed range 1...10Speed accuracy +/- 10 % of nominal slip for 0.2 Tn to Tn torque variationTorque accuracy +/- 15 %Transient overtorque 120 % of nominal motor torque, +/- 10 % for 60 sAsynchronous motor control profile Voltage/Frequency ratio, 2 points
Voltage/Frequency ratio, 5 pointsFlux vector control without sensor, standardVoltage/Frequency ratio - Energy Saving, quadratic U/fVoltage/Frequency ratio, automatic IR compensation (U/f + automatic Uo)
Regulation loop Adjustable PI regulatorMotor slip compensation Adjustable
Automatic whatever the loadNot available in voltage/frequency ratio motor control
Local signalling 1 LED - red - DC bus energizedOutput voltage
2Electrical connection Terminal 50 mm / AWG 1/0 (L1/R, L2/S, L3/T)Terminal 2.5 mm / AWG 14 (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Tightening torque 24 N.m - 212 lb.in (L1/R, L2/S, L3/T)0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
Supply Internal supply: 24 V (21...27 V) DC -
3Communication port protocol APOGEE FLNBACnetLonWorksMETASYS N2Modbus
Connector type 1 RJ451 open style
Physical interface 2-wire RS 485Transmission frame RTUTransmission rate 9600 bps or 19200 bpsData format 8 bits, 1 stop, odd even or no configurable parityType of polarization No impedanceNumber of addresses 1...247Communication service Monitoring inhibitable
Read device identification (43)Read holding registers (03) 2 words maximumTime out setting from 0.1 to 100 sWrite multiple registers (16) 2 words maximumWrite single register (06)
Option card Communication card for LonWorksOperating position Vertical +/- 10 degreeWidth 240 mmHeight 550 mmDepth 244 mmPower dissipation in W 1253 WFan flow rate 429 m3/h
EnvironmentElectromagnetic compatibility Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-61.2/50 s - 8/20 s surge immunity test level 3 conforming to IEC 61000-4-5Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4Radiated radio-frequency electromagnetic field immunity test level 3 conformingto IEC 61000-4-3Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Pollution degree 3 IEC 61800-5-1IP degree of protection IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529
IP20 on upper part without blanking plate on cover conforming to EN/IEC61800-5-1IP41 on upper part conforming to EN/IEC 60529IP41 on upper part conforming to EN/IEC 61800-5-1IP21 conforming to EN/IEC 60529IP21 conforming to EN/IEC 61800-5-1
Vibration resistance 1 gn (f = 13...200 Hz) conforming to EN/IEC 60068-2-81.5 mm (f = 3...13 Hz) conforming to EN/IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27Environmental characteristic Classes 3S2 conforming to IEC 60721-3-3
Classes 3C1 conforming to IEC 60721-3-3Noise level 64 dB conforming to 86/188/EECOperating altitude 1000...3000 m (limited to 2000 m for the Corner Grounded distribution network)
with current derating 1 % per 100 m 40...50 C with derating factor-10...40 C without derating
Ambient air temperature for storage -25...70 C
4Standards EN 55011 class A group 1EN 61800-3EN 61800-3 category C2EN 61800-3 category C3EN 61800-3 environments 1 category C1EN 61800-3 environments 1 category C2EN 61800-3 environments 1 category C3EN 61800-3 environments 2 category C1EN 61800-3 environments 2 category C2EN 61800-3 environments 2 category C3EN 61800-5-1IEC 61800-3IEC 61800-3 category C2IEC 61800-3 category C3IEC 61800-3 environments 1 category C1IEC 61800-3 environments 1 category C2IEC 61800-3 environments 1 category C3IEC 61800-3 environments 2 category C1IEC 61800-3 environments 2 category C2IEC 61800-3 environments 2 category C3IEC 61800-5-1UL Type 1
Product certifications CSAC-TickNOM 117UL
Marking CE
Offer SustainabilitySustainable offer status Green Premium productRoHS Compliant - since 1050 - Schneider Electric declaration of conformityREACh Reference contains SVHC above the threshold - go to CaP for more detailsProduct environmental profile Available Download Product EnvironmentalProduct end of life instructions Available Download End Of Life Manual
5Product data sheetDimensions Drawings
ATV212HD45N4
Dimensions
Dimensions in mm
ATV212H a b c G H K
D22M3XD22N4, D30N4
240 420 214 206 403 10 6
D37N4, D45N4 240 550 244 206 529 10 6
Dimensions in in.
ATV212H a b c G H K
D22M3XD22N4, D30N4
9.45 16.54 8.43 8.11 15.87 0.39 0.24
D37N4, D45N4 9.45 21.65 9.60 8.11 20.83 0.39 0.24
EMC mounting plate (supplied with drive)
Dimensions in mm
ATV212H b1 c1
D22M3XD22N4, D30N4
122 120
D37N4, D45N4 113 127
Dimensions in in.
ATV212H b1 c1
D22M3XD22N4, D30N4
4.80 4.72
D37N4, D45N4 4.45 5.00
6Product data sheetMounting and Clearance
ATV212HD45N4
Mounting Recommendations
ClearanceDepending on the conditions in which the drive is to be used, its installation will require certain precautions and the use of appropriateaccessories.Install the unit vertically:
Do not place it close to heating elements. Leave sufficient free space to ensure that the air required for cooling purposes can circulate from bottom to the top of the unit.
Mounting TypesType A mounting
Type B mounting
Type C mounting
By removing the protective blanking cover from the top of the drive, the degree of protection for the drive becomes IP21. The protectiveblanking cover may vary according to the drive model, see opposite.
Specific Recommendations for Mounting in an Enclosure
To help ensure proper air circulation in the drive: Fit ventilation grilles. Check that there is sufficient ventilation. If there is not, install a forced ventilation unit with a filter. The openings and/or fans must
provide a flow rate at least equal to that of the drive fans (refer to the product characteristics).
Use special filters with UL Type 12/IP54 protection. Remove the blanking cover from the top of the drive.
7Sealed Metal Enclosure (IP54 Degree of Protection)The drive must be mounted in a dust and damp proof enclosure in certain environmental conditions, such as dust, corrosive gases, highhumidity with risk of condensation and dripping water, splashing liquid, etc.This enables the drive to be used in an enclosure where themaximum internal temperature reaches 50C.
8Product data sheetConnections and Schema
ATV212HD45N4
Recommended Wiring Diagram
3-Phase Power Supply
A1: ATV212 driveKM1: ContactorQ1: Circuit breakerQ2: GV2L rated at twice the nominal primary current of T1Q3: GB2CB05S1,S2:
XB4B or XB5A pushbuttons
T1: 100VA transformer 220V secondary(1) Fault relay contacts for remote signalling of the drive status(2) Connection of the common for the logic inputs depends on the positioning of the switch (Source, PLC, Sink)(3) Reference potentiometer SZ1RV1202All terminals are located at the bottom of the drive. Install interference suppressors on all inductive circuits near the drive or connected on thesame circuit, such as relays, contactors, solenoid valves, fluorescent lighting, etc.
Switches (Factory Settings)Voltage/current selection for analog I/O (VIA and VIB)
Voltage/current selection for analog I/O (FM)
Selection of logic type
(1) negative logic(2) positive logic
Other Possible Wiring Diagrams
9Logic Inputs According to the Position of the Logic Type SwitchSource position
Sink position
PLC position with PLC transistor outputs
(1) PLC (1) PLC
2-wire control
F: ForwardR: Preset speed(2) ATV212 control terminals
3-wire control
F: ForwardR: StopRES: Reverse(2) ATV212 control terminals
PTC probe
(2) ATV212 control terminals(3) Motor
Analog InputsVoltage analog inputs
External +10V
(2) ATV212 control terminals(4) Speed reference potentiometer 2.2 to 10k
(2) ATV212 control terminals
10
Analog input configured for current: 0-20mA, 4-20mA, X-YmA
(2) ATV212 control terminals(5) Source 0-20mA, 4-20mA, X-YmA
Analog input VIA configured as positive logic input (Source position)
(2) ATV212 control terminals
Analog input VIA configured as negative logic input (Sink position)
(2) ATV212 control terminals
11
Product data sheetPerformance Curves
ATV212HD45N4
Derating Curves
The derating curves for the drive nominal current (In) depend on the temperature, the switching frequency and the mounting type (A, B or C).For intermediate temperatures (45C for example), interpolate between 2 curves.
X Switching frequency