Upload
anne-carson
View
217
Download
0
Tags:
Embed Size (px)
Citation preview
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
www.btwholesale.com
Tier 1 Pricing Principles
www.btwholesale.com
To make your own calculations Operators can calculate their own Tier 1 prices by using information BT has
made available on www.btwholesale.com
The information to enable these calculations are held in several files as follows:-
• Postcode to Serving Exchange File (PSEF) - Contains all instances of a post code where BT is currently providing PSTN access to a site and therefore has already identified the true Serving Exchange for that site.
• Supplementary Post Code List - contains valid post codes not listed in the Postcode to Serving Exchange File.
• PPC Serving Exchange to T1 Node - lists all the BT Serving Exchange Node matched to the nearest Tier 1 node.
• DPCN Nodes 1141Codes - contains a list of all Digital Private Circuit Network (DPCN) nodes
• SDH Node list - contains a list of all SDH serving nodes.
• Tier 1 Node Aggregation – contains the aggregated Tier 1 Nodes
Full details on using the above files to calculate PPC circuit distance is detailed in the PPC Circuit Distance Calculation Manual
Postcode to Serving Exchange Mapping
www.btwholesale.com
Initial Order CP to BT
Customer Contacts BT for PPC and supplies the following information to BT
1. Third party post code or Eastings and Northings.
2. The POH SDH/DPCN Node
3. Circuit Option
BT enters details supplied by customer into PPC Pricing Tool. The Pricing Tool calculates the Trunk and Termination segment distance. The distance is then entered into the order handling system. At Firm Offer Confirmation (FOC) the circuit distance and circuit provision costs is given to customer.
Start customer requires PPC
www.btwholesale.com
Tier 1 Node Pricing Examples
www.btwholesale.com
Notes on PPC Pricing Examples•For circuit bandwidths from 64K to 960K, prices are based on the tier 1 node pricing distance between the third party BT serving exchange and the Digital Private Circuit Network (DPCN) node nearest to the point of handover. DPCN bearers are charged on the radial distance between the DPCN node and the BT SDH node.
•1mbit –155mbit circuit prices are based on the tier 1 node pricing principle between the third party BT serving exchange and the BT serving node.
•CSH, ISH and 3rd party infrastructure prices are for indicative purposes only. The customer can configure the Add-Drop Mux (ADM) to meet their specific requirements.
•These examples are for illustrative purposes only and should not be used as the basis for any quotations – always consult the carrier price list for the most up to date pricing information.
•Circuits are shown from the 3rd party customer site to Point of Handover (POH) and onto the annex 2 operator’s network.
www.btwholesale.com
Principles and Guidance
•Pricing is based on the 3 elements of a PPC circuit•Big pipe” from an OLO network POH to the BT network (A end)•The required bandwidth path across the BT network• A local end path to your third party end users site (B end)
•Each element is priced for •The connection charge and the rental charge
•Connection charge•Infrastructure charges for 3rd party site, POH and circuit connection charge across the BT network.•Excess charges as required at the 3rd party site and the POH
•Rental charge•Local end fixed charges•Main Link fixed charge + Main Link segment charges + Terminating segment charges + Optional Enhanced Maintenance charge•Rental on POH infrastructure
•Connection charge at 3rd party site•Is this an existing or new 3rd party site?•Is access required to Marconi Synchronous Hierarchy (MSH) network? •Are batteries required?•Choose Network Terminating Unit NTU or ADM, tributary cards and protection as appropriate for site•Fibre working type and wavelengths are determined by BT on site survey•Use Carrier Price list (CPL) section 8.02 to choose infrastructure as appropriate•Use CPL section 8.06 for excess charges as required at 3rd party site
•Connection charge•Use CPL section 8.02 for the circuit connection charges across the BT network
•Connection charge at POH•Is this an existing or new POH?•Is access required to DPCN or MSH network? •Are batteries required?•Choose ADM, tributary cards, fibre working,network access and protection as appropriate for site•Fibre working type and wavelengths are determined by BT on site survey•Use CPL section 8.01 (CSH), 8.01 (ISH) or 8.01 (ISH- Extn) to choose infrastructure as appropriate•Use CPL section 8.06 for excess charges as required at POHwww.btwholesale.com
Principles and Guidance
www.btwholesale.com
Principles and Guidance•Maintenance charge
•Use CPL section 8.03 for the appropriate circuit local end fixed charge at 3rd Party end
•Use CPL section 8.03 for the circuit main link fixed charge at 3rd Party end
•Calculate the terminating segment and the main link segment distances using files available on BTwholesale website. Use CPL section 8.03 to calculate charges before and after the SDH Tier1 breakpoint
•Enhanced Maintenance charge (Optional)•Use CPL section 8.03 to calculate charges based on the total radial distance calculations.
•POH Rental•Use section 8.01 (CSH), 8.01 (ISH) or 8.01 (ISH- Extn) for the appropriate rental charges on infrastructure provision and 8.01 part 1.6 in respect of the efficient use of PoH Infrastructure rental.
Tier 1 Node Pricing The methodology used in the new Aggregate nodal calculations is based on the following:
Main Link (A)
T1 to T1 (B)
POH (SDH/DPCN) LSE
POH to POH T1(C)
POH AN LSE AN
LSE to LSE T1(D)
T1(a) T1(c)T1(b) T1(d)
Proposed T1 Terminating
Proposed T1 Trunk
Current T1 Trunk
Aggregation Node Virtual Boundary
FE
Main Link (A)
T1 to T1 (B)
POH (SDH/DPCN) LSE
POH to POH T1(C)
POH AN LSE AN
LSE to LSE T1(D)
T1(a) T1(c)T1(b) T1(d)
Proposed T1 Terminating
Proposed T1 Trunk
Current T1 Trunk
Aggregation Node Virtual Boundary
Proposed T1 Terminating
Proposed T1 Trunk
Current T1 Trunk
Aggregation Node Virtual Boundary
FE
.Note: In cases where the methodology used to calculate the PPC distances is revised due to the presence of one or more new Aggregation Nodes, the new Trunk proportion is calculated as A*B/(B+C+D+E+F). The previous Trunk proportion methodology was A*B/(B+C+D).
The methodology used in the new Aggregate nodal calculations is based on the following:
Main Link (A)
T1 to T1 (B)
POH (SDH/DPCN) LSE
POH to POH T1(C)
POH AN LSE AN
LSE to LSE T1(D)
T1(a) T1(c)T1(b) T1(d)
Proposed T1 Terminating
Proposed T1 Trunk
Current T1 Trunk
Aggregation Node Virtual Boundary
FE
Main Link (A)
T1 to T1 (B)
POH (SDH/DPCN) LSE
POH to POH T1(C)
POH AN LSE AN
LSE to LSE T1(D)
T1(a) T1(c)T1(b) T1(d)
Proposed T1 Terminating
Proposed T1 Trunk
Current T1 Trunk
Aggregation Node Virtual Boundary
Proposed T1 Terminating
Proposed T1 Trunk
Current T1 Trunk
Aggregation Node Virtual Boundary
FE
.Note: In cases where the methodology used to calculate the PPC distances is revised due to the presence of one or more new Aggregation Nodes, the new Trunk proportion is calculated as A*B/(B+C+D+E+F). The previous Trunk proportion methodology was A*B/(B+C+D).
www.btwholesale.com
Tier 1 Node Pricing
Efficient / In-Efficient POH Rental Charges
In the Leased Line Charge Control published 2 July 2009 Ofcom directed BT show separately the PoH charges that historically have been embedded within PPC Local End Charges and introduce a cost recovery mechanist that would incentivised migration to new aggregated PoHs. Under this approach, circuits handed over new PoHs would not attract the separate new PoH charges and incentivised CPs to migrate to the new efficient PoH as it would allow them to reduce (and ultimately avoid) the new PoH rental charges.
– New rental charges on PoH Infrastructure where the ADM is considered to be Efficient PoH (SMA-1; SMA-4 & SMA-16). For CSH & ISH Extn PoH there will be an additional Bearer Charge (CPL B8.01 part 1.6 PoH Rental Charges refs)
–Third Party PoH fixed Charge associated to circuit rental where the circuit is provided using in-efficient ADMs (non-PPC ADMs; 4x2 & 16x2)
CSH & ISH Extn PoH = ADM rental + ADM PoH rental + Bearer charge =
ISH PoH = ADM rental + ADM PoH rental charge
Circuit rental includes the 3rd Party rental charge where it is provided using in-efficient PoH i.e. 4x2; 16x2 etc. Where the PoH is efficient the circuit rental will not include the 3rd Party PoH fixed charge
Efficient Circuit Rental = Local End fixed charge + Main Link total charge
In-Efficient Circuit Rental = Local End fixed charge + 3rd Party PoH fixed charge + Main Link total charge.
Efficient use of PoH Infrastructure Rental• All CSH & ISH Extension Infrastructure ADMs will incur the new PoH Infrastructure ADM
rental and Bearer fixed rental charge as detailed in B8.01 part 1.6.
Example
Rental Charge
SMA-16 ADM no trib interface (single fibre working) existing site £1315.77
SMA-16 PoH Infrastructure £7764.00
Bearer PoH Infrastructure £ 322.00
Total SMA-16 per annum Fixed Rental Charge£9401.77
• All ISH ADMs will incur the new PoH Infrastructure ADM rental charge as detailed in B8.01 part 1.6
Example:
Rental Charge
SMA-16 ADM with single STM-16 handover (1300nm) £ 983.22
SMA-16 PoH Infrastructure £7764.00
Total SMA-16 per annum Fixed Rental Charge£8747.22
Note: The charges quoted are for information purposes only. To ensure you have the correct charges please refer to the PPC Price List.
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
3rd Party End NTE
64K PPC Connection Charge ExampleBT ServingExchange
DPCN CSHBT SDH
NodeDPCN
3rd Party Customer Link Infrastructure:
Section 8.02 of CPL
NTU 64K-256K on existing copper£587.15 single chargeOrNTU 64K-256K on new copper£693.18 single charge
DPCN 2Mb Bearer 64Kbit/s Circuit
NTU 64K – 256K
POHInfrastructure
Connection of a New Circuit
Section 8.02 of CPL
Provision charge 64-960 Kbit/s£499.94 single charge
CSH Infrastructure: Existing site
Section 8.01 of CPL
16x2 or 4x2– legacy equipment oNo chargeUse of existing 2Mb bearerNo charge
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
64K PPC Annual Rental Charge Example
Example: Terminating segment distance = 17Km and Trunk segment distance =18Km
Comprises:Main Link Fixed Charge
£130.02Terminating segment charges
£1.81/Km x 17km= £30.77
Trunk Segment Charges £3.22/Km x 18km
=£57.96Optional Enhanced Maintenance:
£ 80.62 plus £0.02KmTotal charge (@ 35 Km) = £81.32
3rd Party End NTE
BT ServingExchange
DPCN CSHBT SDH
NodeDPCN
DPCN 2Mb Bearer
POHInfrastructure
NTU 64K – 256K 64Kbit/s Circuit
Local end Fixed Charge £479.34 Main Link Total Charge £300.07POH Fixed Charge £98.40
Example: Rental for circuit provided over:Efficient PoH = £779.41In-Efficient PoH = £877.81
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
320K PPC Connection Charge Example
3rd Party Customer Link Infrastructure:
Section 8.02 of CPL
NTU 320K-640K on existing copper£604.87 single chargeOrNTU 320K-640K on new copper£808.82 single charge
320Kbit/s Circuit
3rd Party End NTE
BT ServingExchange
DPCN CSHBT SDH
NodeDPCN
DPCN 2Mb Bearer
NTU 320K - 960K
POHInfrastructure
CSH Infrastructure: (Existing site)
Section 8.01 of CPL
STM-1 legacy equipmentNo charge
2Mb Bearer access – required for access to DPCN (if no spare capacity on existing bearers)£1,611.23 single charge
Connection of a New Circuit
Section 8.02 of CPL
Provision charge 64-960 Kbit/s£499.94 single charge
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
320K PPC Annual Rental Charge Example3rd Party End NTE
BT ServingExchange
DPCN CSHBT SDH
NodeDPCN
Bearer Rental Charges
2Mb bearer access to DPCN £389.13 per annum
Plus Distance ChargeAssume 5Km radial distance POH SE to
DPCN Node£42.56/Km
=£212.80Total charge = £601.93
Comprises:Main Link Fixed Charge
£587.98Terminating Segment Charges
£8.17/Km= £138.89
Trunk Segment Charges £21.48/Km= £386.64
Optional Enhanced Maintenance:£ 88.12 plus £0.08Km
Total charge (@35Km) = £90.92
DPCN 2Mb Bearer
POHInfrastructure
NTU 320K - 960K 320Kbit/s Circuit
Example: Terminating segment distance = 17Km
Trunk segment distance =18Km – refer to section 8.03 of CPL – Total Circuit Rental £1782.17
Local end Fixed Charge £479.34 Main Link Total Charge £1,204.43POH Fixed Charge £98.40
Example: Rental for circuit provided over:Efficient PoH = £1683.77In-Efficient PoH = £1782.17
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
1M PPC Connection Charge Example
1Mb Infrastructure
POH Infrastructure
Connection of New Circuit
Section 8.02 of CPL
1 Mbit/s Circuit Provision£1,695.04 Single charge
ISH Infrastructure:
Section 8.01 of CPL
ISH Configuration STM-1SMA-4 ADM with single STM-1 handover (1300nm)£14,703.27
3rd Party Customer Link Infrastructure:
Section 8.02 of CPL
1 Mb/s circuit on new copper£1,254.98 Single charge
Section 8.06.2 – Excess Construction ChargesAs required
3rd Party End NTE
BT ServingExchange
ISHBT SDH
Node
1Mbit/s Circuit
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
1M PPC Annual Rental Charge Example
1Mbit/s Circuit1Mb Infrastructure
POH Infrastructure
Example: Terminating segment distance = 20Km
Trunk segment distance =20Km – refer to section 8.03 of CPL – Total Circuit Rental £3,192.63
Comprises:Main Link Fixed Charge
£426.63
Terminating Segment Charges £46.93/Km= £938.60
Trunk Segment Charges £38.74/Km= £774.80
Optional Enhanced Maintenance:£137.13 plus £1.53/Km
Total charge (@40Km) = £198.33
ISH Infrastructure Rental
Section 8.01 of CPL
ISH Configuration STM-1SMA-4 ADM with single STM-1 handover (1300nm)£5139.20 per annum
3rd Party End NTE
BT ServingExchange
ISHBT SDH
Node
Local end Fixed Charge £686.99 Main Link Total Charge £2,338.36POH Fixed Charge £167.28
Example: Rental for circuit provided over:Efficient PoH = £3,025.35In-Efficient PoH = £3,192.63
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
2M PPC Connection Charge Example
2Mbit/s Circuit2MbInfrastructure
POH Infrastructure
Connection of New Circuit
Section 8.02 of CPL
2 Mbit/s Circuit Provision£1,695.04 Single charge
CSH Infrastructure:
Section 8.01 of CPL
CSH Configuration SMA-4Use existing SMA-4 ADM with no trib interfaces (dual fibre working)No additional chargeSTM-1 optical (1300nm) trib interface (1 port) £1,930.54 connectionSTM-1 optical (1300nm) trib card (1 port), required for MSP protection £742.19 connection
3rd Party Customer Link Infrastructure:
Section 8.02 of CPL
Provide a 2 Mbit 4x2 at existing fibre site£4,134.62 single chargeAddition charge to provide new fibre infrastructure at new site£2,191.94 single charge
Section 8.06.2 – Excess Construction ChargesAs required
3rd Party End NTE
BT ServingExchange
CSHBT SDH
Node
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
2M PPC Annual Rental Charge Example
Local end Fixed Charge £686.99 Main Link Total Charge £2,338.36
Comprises:Main Link Fixed Charge
£426.63Terminating Segment Charges
£46.93/Km= £ 938.60
Trunk Segment Charges £38.74/Km= £774.80
Optional Enhanced Maintenance:£ 137.13 plus £1.53Km
Total charge (@40Km) = £198.33
CSH Infrastructure Rental:
Section 8.01 of CPL
CSH Configuration SMA-4SMA-4 ADM with no trib interfaces (dual fibre working 1300nm)£6119.11 per annumSTM-1 optical (1300nm) trib interface (1 port) £36.27 per annumSTM-1 optical (1300nm) trib card (1 port), required for MSP protection £13.90 per annum
2MbInfrastructure
POH Infrastructure
3rd Party End NTE
BT ServingExchange
CSHBT SDH
Node
2Mbit/s Circuit
Example: Terminating segment distance = 20Km
Trunk segment distance =20Km – refer to section 8.03 of CPL – Total Rental £3192.63
POH Fixed Charge £167.28
Example: Rental for circuit provided over:Efficient PoH = £3,025.35In-Efficient PoH = £3,192.63
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
34-45M PPC Connection Charge Example
34 Mbit/s Circuit34 Mb Infrastructure
POH Infrastructure
New Circuit on Spare Capacity
Section 8.02 of CPL
Charge for new PPC provided on spare capacity on 3rd party link infrastructure where such infrastructure installed before 23/12/02 34/45 Mbit/sNo additional charge
Connection of New Circuit
Section 8.02 of CPL
34-45 Mbit/s and above circuit provision£1,593.44 single charge
CSH Infrastructure: New Site
Section 8.01 of CPL
CSH Configuration SMA-4SMA-4 ADM no trib I/F single fibre working existing site£46,233.56Additional New Site charge£2,191.94STM-1 Optical (1300nm) trib interface£1,930.54STM-1 optical (1300nm) trib card, required for MSP Protection£764.36Stand-by batteries£409.11Section 8.06.2 – Excess Construction chargesAs required
3rd Party End NTE
BT ServingExchange
CSHBT SDH
Node
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
34-45M PPC Annual Rental Charge Example
Comprises:Main Link Fixed Charge
£2,962.19Terminating segment charges
£465.10/Km= £9,302.00
Trunk Segment Charges £358.90Km= £7,178.00
Optional Enhanced Maintenance:£202.03 plus £2.89/Km
Total charge (@40Km) = £317.63
CSH Infrastructure Rental:
Section 8.01 of CPL
CSH Configuration SMA-4SMA-4 ADM no trib I/F single fibre working existing site£6048.27 per annumSTM-1 Optical (1300nm) trib interface£36.27 per annumSTM-1 optical (1300nm) trib card, required for MSP Protection£13.50 per annumStand-by batteries£7.44 per annum
34 Mbit/s Circuit34 Mb Infrastructure
POH Infrastructure
3rd Party End NTE
BT ServingExchange
CSHBT SDH
Node
Local end Fixed Charge £2,386.49 Main Link Total Charge £19,759.82
Example: Terminating segment distance = 20Km
Trunk segment distance =20Km – refer to section 8.03 of CPL – Total Rental £ 22,992.55
POH Fixed Charge £846.24
Example: Rental for circuit provided over:Efficient PoH = £22,146.31In-Efficient PoH = £22,992.55
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
155M PPC Connection Charge Example
3rd Party Customer Link Infrastructure:
Section 8.02 of CPL
3rd Party customer sited SMA-4 ADMwith no trib I/f (single fibre working)£29,975.65Additional New Site charge£2,191.94STM-1 Optical (1300nm) trib card (1 port)£742.19Stand-by batteries£409.11Section 8.06.2 – Excess Construction ChargesAs required
Connection of New Circuit
Section 8.02 of CPL
140 Mbit/sec and aboveProvision £1,804.72 single charge
ISH Infrastructure:
Section 8.01 of CPL
ISH Configuration STM-4SMA-4 ADM with single STM-4 handover (1300nm) £25,332.28
155 Mbit/s Circuit155 Mb Infrastructure
POH Infrastructure
3rd Party End NTE
BT ServingExchange
ISHBT SDH
Node
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
155M PPC Annual Rental Charge Example
Comprises:Main Link Fixed Charge
£10,391.84Terminating segment charges
£535.00 /Km= £10,700.00
Trunk Segment Charges £191.10/Km= £3,822.00
Optional Enhanced Maintenance:£378.65 plus £3.92Km
Total charge (@40Km) = £535.45
155 Mbit/s Circuit155 Mb Infrastructure
POH Infrastructure
3rd Party End NTE
BT ServingExchange
ISHBT SDH
Node
ISH Infrastructure:
Section 8.01 of CPL
ISH Configuration STM-4SMA-4 ADM with single STM-4 handover (1300nm) £5651.66 per annum
Example: Terminating segment distance = 20Km
Trunk segment distance =20Km – refer to section 8.03 of CPL – Total Rental £ 37,024.35
Local end Fixed Charge £10,000.66 Main Link Total Charge £25,449.29POH Fixed Charge £1,574.40
Example: Rental for circuit provided over:Efficient PoH = £35,449.95In-Efficient PoH = £37,024.35
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
Protected Path Variant 1
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
2 Mbit/s Protected Path V1 Connection Charge Example
Connection of New Circuit
Section 8.02 of CPL
2 Mbit/s Circuit Provision£1,695.04 Single charge
ISH Infrastructure:
Section 8.01 of CPL
ISH Configuration STM-1SMA-4 ADM with single STM-1 handover (1500nm)£16,184.70
Third Party Customer Link Infrastructure:
Section 8.02 of CPL
SMA-1 ADM with no trib interfaces (dual fibre working 1300nm) - existing site £17,910.43 Single charge2 X 2Mbit/s trib card£3,496.74 X 2 = £6993.48Section 8.06.2 – Excess Construction ChargesAs required
2Mb Infrastructure
PoH Infrastructure 2 Mbit/s Circuit
Third Party End ADM
BT ServingExchange
ISH
BT SDHNode
BT ServingExchange
BT SDHNode
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
2 Mbit/s Protected Path V1 Rental Charge Example
Main Link Total Charge Comprises :
Main Link Fixed Charge £515.59
Terminating Segment charges @ £47.61/Km = £952.20
Trunk Segment charges @ £102.24 Km = £2,044.00
EnhancedCare Maintenance is standard
ISH Infrastructure Rental
Section 8.01 of CPL
ISH Configuration STM-1SMA-4 ADM with single STM-1 handover (1550nm)£5490.07 per annum
Third Party End ADM
BT ServingExchange
ISH
BT SDHNode
BT ServingExchange
BT SDHNode
Third Party Infrastructure
PoH Infrastructure 2 Mbit/s Protected Path Circuit
Example: Terminating Segment distance = 20Km
Trunk Segment distance =20Km – refer to section 8.03 of CPL – Total Rental £4,550.75
Local end Fixed Charge £871.68 Main Link Total Charge £3511.79POH Fixed Charge £167.28
Example: Rental for circuit provided over:Efficient PoH = £4,383.47In-Efficient PoH = £4,550.75
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
Protected Path Variant 2
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded
www.btwholesale.com
Generic Protected Path V2 Architecture
3rd Party Site
PoH 2
PoH 1
Path B
Path A
D&CI Path
Due to the unique nature of the PPC PP V2 network architecture, calculation of the distance related element of the rental charge is based on the following methodology: “the average of the two legs from the third party site to the points of handover, plus the distance between the two points of handover”. Each path has a terminating and trunk element, the average is found by adding the trunk elements of paths A and B together and dividing by two, then adding the terminating elements of paths A and B together and dividing by two. This gives an average trunk and terminating element for paths A and B; this is added to the trunk and terminating elements of the Drop and Continue Interworking (D&CI) path, to give a total trunk and terminating distance charge for the PPC PP V2 Circuit.
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
2 Mbit/s Protected Path V2 Connection Charge Example
Connection of New Circuit
Section 8.02 of CPL
2 Mbit/s Circuit Provision£7382.86 Single charge
Infrastructure:
Example assumes the customer has already purchased the pre-requisite Point of Handover and Third Party infrastructure to support PPC PP V2
2Mb Infrastructure
PoH Infrastructure 2 Mbit/s Circuit
CSH
Third Party End ADM
BT ServingExchange
T SDHNode
BT ServingExchange
BT SDHNodeCSH
D&CI path
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded
www.btwholesale.com
Generic Protected Path V2 Architecture
3rd Party Site
PoH 2
PoH 1
Path B
Path A
D&CI Path
Trunk Elements (Km)Path A 10Path B 20Path A & B Average (10 + 20)/2 15D&CI Path 25Total Trunk (Km) 15+25 40
Terminating Elements (Km)Path A 6Path B 8Path A & B Average (6+8)/2 7 D&CI Path 5Total Terminating (Km) 7+5 12
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded
www.btwholesale.com
2 Mbit/s Protected Path V2 Rental Charge Example
Third Party Infrastructure
PoH Infrastructure 2 Mbit/s Protected Path Variant 2 Circuit
Main Link Total Charge Comprises :
Main Link Fixed Charge £515.59
Terminating Segment charges @ £47.61/Km = £ 571.32
Trunk Segment charges @ £102.24 Km = £ 4089.60
EnhancedCare Maintenance is standard
Infrastructure
Example assumes the customer has already purchased the pre-requisite Point of Handover and Third Party infrastructure to support PPC PP V2
CSH
Third Party End ADM
BT ServingExchange
T SDHNode
BT ServingExchange
BT SDHNode
CSH
D&CI path
Example: Terminating Segment distance = 12Km
Trunk Segment distance =40Km – refer to section 8.03 of CPL – Total Rental £ 6215.47
Local end Fixed Charge £871.68 Main Link Total Charge £5176.51POH Fixed Charge £167.28
Example: Rental for circuit provided over:Efficient PoH = £6048.19In-Efficient PoH = £6215.47
www.btwholesale.com
PPC 155 MSH - MSH
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
PPC 155 MSH - MSH Connection Charge Example
155 Mbit/s Circuit155 Mb Infrastructure
POH Infrastructure
3rd Party Customer Link Infrastructure:
Section 8.02 of CPL
3rd Party customer sited MSH51 ADMwith no trib (dual fibre working 1550nm) – existing site
£58,057.95 Additional New Site charge
£2191.94 STM-1 electrical trib card (4 port)
£969.91Stand-by batteries
£409.11Section 8.06.2 – Excess Construction ChargesAs required
Connection of New Circuit
Section 8.02 of CPL
140 Mbit/sec and aboveProvision £1804.72 single charge
ISH Infrastructure:
Section 8.01 of CPL
ISH Configuration MSH51MSH51 ADM with single STM-16 handover (1300nm) plus Optional STM-16 1550nm handover £24,977.29 + £584.48= £25,561.77
3rd Party End NTE
BT ServingExchange
ISHBT ServingExchange
MSHNode
MSHNode
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
PPC 155M MSH – MSH Annual Rental Charge Example
155 Mbit/s Circuit155 Mb Infrastructure
POH Infrastructure
Local end Fixed Charge £10,000 Core Transportation Link Total
Charge = £17,630.09
Comprises:Main Link Fixed Charge
£10,391.84Core Transportation Link
£167.57/Km (MSH –MSH)= £6,702.80
Optional Enhanced Maintenance:£378.65 .00 plus £3.92/Km
Total charge (@40Km) = £535.45
ISH Infrastructure:
Section 8.01 of CPL
ISH Configuration MSH51MSH51 ADM with single STM-16 handover (1300nm) plus Optional STM-16 1550nm handover£8238.83 per annum
Example: Core Transportation Link (MSH to MSH) = 40Km – refer to section 8.03 of CPL
– Total Rental £29,204.49
3rd Party End NTE
BT ServingExchange
ISHBT ServingExchange
MSHNode
MSHNode
POH Fixed Charge £1574.40
Example: Rental for circuit provided over:Efficient PoH = £27,630.09In-Efficient PoH = £29,204.49
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
Ancillary Charges Example
Carriage Way
3rd party External wall
8 metres duct
2 metres
Footway box
½ metre
½ metre
BT servingexchange
Always consult the current Carrier Price List. Examples based on 10 March 2010 Price ListUncontrolled when downloaded www.btwholesale.com
Ancillary Charges Example
Ancillary Charges are the additional Excess Construction charges which are often needed to enable circuit provision. This charge is a pass through charge; the charges can be found in the Openreach Price List - Section 4.1.3 – Excess Construction Charges.
3010 metres of Cable (Fibre & Copper) are included in a “Standard” delivered circuit. No extra Excess Construction Charge will be applied to a Standard delivered circuit where the cabling required is upto and including 3010 metres. Where it requires more than 3010 meters to deliver a standard delivered circuit, the amount of cable over the 3010 metres will be charged at the rate detailed in the Openreach Price List.
Where the circuit requirement is for non-standard delivery i.e. for resilience purposes, the whole amount of cable will be charged.