2
Upflow / Horizontal Gas Furnace"Fan-Assisted Combustion" TAG: _________________________________ © 2009 American Standard Heating & Air Conditioning Specification 7/8" DIA. K.O. ELECTRICAL CONNECTION (ALTERNATE) 1-1/2" DIA. K.O. GAS CONNECTION (ALTERNATE) 7/8" DIA. HOLES ELECTRICAL CONNECTION 1-1/2" DIA. HOLE GAS CONNECTION 40" 1/2" 3-3/4" 28-1/4" 5-5/16" 3/8" 2-1/8" 23-1/2" 3-13/16" 3/4" 28-3/8" 19-5/8" 5/8" 4-1/16" 13-1/4" 22-1/2" 28-1/4" 8-1/4" 5/8" 14-1/2" 13" 3/4" 3/4" 3-15/16" 9-5/8" 5/8" 2-1/16" 4" DIAMETER FLUE CONNECT 2-1/16" 1/2" AUD1A040A9241A FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.) MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90 AUD1A040A9241A 4 - 3 - 2 - 1 - HIGH - Black MED.-HIGH - Blue MED.-LOW - Yellow LOW - Red 1018 847 716 617 1004 832 701 599 982 809 678 575 950 779 648 544 910 742 610 507 860 697 585 463 802 644 512 413 763 585 452 357 660 517 384 294 CFM VS. TEMPERATURE RISE MODEL CFM (CUBIC FEET PER MINUTE) 500 600 700 800 900 1000 AUD1A040A9241A 59 49 42 37 33 30 AUD1A040-SPEC-1A

American Standard Upflow / Horizontal Gas Furnace - 'Fan ... · Upflow / Horizontal Gas Furnace"Fan-Assisted Combustion" ... 610 507 860 697 585 463 802 644 ... American Standard

  • Upload
    tranbao

  • View
    300

  • Download
    0

Embed Size (px)

Citation preview

Page 1: American Standard Upflow / Horizontal Gas Furnace - 'Fan ... · Upflow / Horizontal Gas Furnace"Fan-Assisted Combustion" ... 610 507 860 697 585 463 802 644 ... American Standard

Upflow / Horizontal GasFurnace"Fan-AssistedCombustion"

TAG: _________________________________

© 2009 American Standard Heating & Air Conditioning

Specification

7/8" DIA. K.O.ELECTRICALCONNECTION(ALTERNATE)

1-1/2" DIA. K.O. GASCONNECTION(ALTERNATE)

7/8" DIA. HOLESELECTRICALCONNECTION

1-1/2" DIA. HOLEGAS CONNECTION

40"

1/2"

3-3/4"

28-1/4"

5-5/16"

3/8"

2-1/8"

23-1/2"

3-13/16"

3/4"

28-3/8"19-5/8"

5/8"

4-1/16"

13-1/4"

22-1/2"

28-1/4"

8-1/4"

5/8"14-1/2"

13"

3/4"

3/4"

3-15/16"

9-5/8"

5/8"

2-1/16"

4" DIAMETERFLUE CONNECT

2-1/16"

1/2"

AUD1A040A9241A

FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (IN. W.C.)MODEL SPEED TAP 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80 0.90

AUD1A040A9241A 4 -3 -2 -1 -

HIGH - BlackMED.-HIGH - BlueMED.-LOW - YellowLOW - Red

1018847716617

1004832701599

982809678575

950779648544

910742610507

860697585463

802644512413

763585452357

660517384294

CFM VS. TEMPERATURE RISE

MODELCFM (CUBIC FEET PER MINUTE)

500 600 700 800 900 1000

AUD1A040A9241A 59 49 42 37 33 30

AUD1A040-SPEC-1A

Page 2: American Standard Upflow / Horizontal Gas Furnace - 'Fan ... · Upflow / Horizontal Gas Furnace"Fan-Assisted Combustion" ... 610 507 860 697 585 463 802 644 ... American Standard

Since American Standard Heating & Air Conditioning has apolicy of continuous product and product data improvement, itreserves the right to change specifications and design withoutnotice.

American StandardHeating & Air Conditioning6200 Troup HighwayTyler, TX 75707

LibraryProduct SectionProductModelLiterature TypeSequenceDateFile No.Supersedes

TYPERATINGS 22222Input BTUHCapacity BTUH (ICS) 33333AFUETemp. rise (Min.-Max.) °F.BLOWER DRIVEDiameter-Width (In.)No. UsedSpeeds (No.)CFM vs. in. w.g.Motor HPR.P.M.Volts/Ph/HzCOMBUSTION FAN - TypeDrive - No. SpeedsMotor HP - RPMVolts/Ph/HzF.L. AmpsFILTER — Furnished?Type RecommendedHi Vel. (No.-Size-Thk.)

1 Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.32 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.3 Based on U.S. Government Standard Tests.4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.

NATURAL GAS MODELS — Central heat-ing furnace designs are certified to ANSIZ21.47 / CSA 2.3 for both natural and L.P.gas. Limit setting and rating data wereestablished and approved under stan-dard rating conditions using American Na-tional Standards Institute standards.

SAFE OPERATION — The Integrated Sys-tem Control has solid state devices, whichcontinuously monitor for presence of flame,when the system is in the heating mode ofoperation. Dual solenoid combinationgas valve and regulator provide extrasafety.

QUICK HEATING— Durable, cycle tested,heavy gauge aluminized steel heat ex-changer quickly transfers heat to providewarm conditioned air to the structure. Lowenergy power vent blower, to increaseefficiency and provide discharge of gasfumes to the outside, allows common vent-ing with hot water heater.

Mechanical SpecificationsBURNERS — Multi-port, in-shot burnerswill give years of quiet and efficient service.All models can be converted to L.P. gaswithout changing burners.

INTEGRATED SYSTEM CONTROL— Ex-clusively designed operational program pro-vides total control of furnace limit sensors,blowers, gas valve, flame control and in-cludes self diagnostics for ease of service.

AIR DELIVERY — The multispeed, direct-drive blower motor, with sufficient airflowrange for most heating and cooling re-quirements, will switch from heating tocooling speeds on demand from roomthermostat. The blower door safety switchwill prevent or terminate furnace operationwhen the blower door is removed. (Fanrelay and 35VA control transformer is stan-dard).

STYLING — Heavy gauge steel and"wraparound" cabinet construction isused in the cabinet with baked-on enamelfinish for strength and beauty. The heatexchanger section of the cabinet is com-pletely lined with foil-faced fiberglass insu-lation. This results in quiet and efficientoperation due to the excellent acousticaland insulating qualities of fiberglass.

FEATURES AND GENERAL OPERA-TION — These High Efficiency Gas Fur-naces employ a Hot Surface Ignition sys-tem, which eliminates the waste of a con-stantly burning pilot. The integrated sys-tem control lights the main burners upon ademand for heat from the room thermo-stat. Complete front service access.

a. Low energy power venter.b. Vent proving differential switch.

VENT COLLAR — Size (in.)HEAT EXCHANGERType-Fired

-UnfiredGauge (Fired)ORIFICES — MainNat.Gas. Qty. — Drill SizeL.P. Gas Qty. — Drill SizeGAS VALVEPILOT SAFETY DEVICETypeBURNERS — TypeNumberPOWER CONN. — V/Ph/Hz 44444Ampacity (In Amps)Max. Overcurrent Protection (amps)PIPE CONN. SIZE (IN.)DIMENSIONSCrated (In.)Uncrated (In.)WEIGHTShipping (Lbs.) / Net (Lbs)

General Data 11111

Upflow / Horizontal

40,00032,00080.0

30 - 60DIRECT10 x 6

14

See Fan Performance1/5

1080115/1/60

CentrifugalDirect - 1

1/50 - 3180115/1/60

1.09No

High Velocity1 - 17x25 - 1in.

4 Round

Alum. Steel

20

2 — 452 — 56

Redundant - Single Stage

Hot Surface IgnitionMultiport Inshot

2115/1/60

5.4151/2

H x W x D41- 3/4 x 16-1/2 x 30-1/2

40 x 14-1/2 x 28

119 / 110