23
Amy Bryan Director of Residential Marketing Jackson EMC Michelle Simmons, Oglethorpe Power Co. Tristan de Frondeville, SkyCentrics Bill Hosken, AO Smith

Amy Bryan Director of Residential Marketing Jackson EMC … · 2020. 2. 3. · Director of Residential Marketing Jackson EMC Michelle Simmons, Oglethorpe Power Co. Tristan de Frondeville,

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Amy BryanDirector of Residential MarketingJackson EMC

    Michelle Simmons, Oglethorpe Power Co.

    Tristan de Frondeville, SkyCentrics

    Bill Hosken, AO Smith

  • What is the CEA – 2045 Standard?

  • Upfront cost practical for mainstream retail(Future grid connectivity is uncertain, and no interest from the consumer)

    Communication technologies-Diverse – different needs and capabilities in different regions

    Evolving – shorter expected service life than the appliances

    Diverse demand response use cases(Modules provide an opportunity for housing “logic”)

  • Standard Modular Interface for Demand Response

    Field evaluation of the standard

    Products that support the standard

    Operated in active DR programsEvaluate capabilities-

    All kinds of DR systems and programs

    Technology evolution without impacting consumer products

    Single communication module for all end devices

    Potential of no electrician or utility service call to add device into program

  • Provide-Cost effective way for residential products to be made smart grid ready, off-the-shelf

    Modular interface flexibility in the selection of communication technologies

    Ease of DR program participation, self-install, no truck roll

    Accommodate rapid technology evolution to avoid appliance obsolescence related to changing communication technologies

  • 10 Grid-enabled electric water heaters

    Water heater monitorWater flow

    Inlet and Outlet temperature

    Current and Voltage Measurement

    SkyCentrics CEA-2045 load management device

    EPRI CEA-2045 interface monitor

    Term of research one year after installation

  • Demonstrate use of CEA-2045 load control protocol

    Measure load control impact

    Verify consumer comfort

    Investigate direction of future water heating load control

    Maintain residential water heating revenue

    Evaluate cutting edge demand response technology

    Collaborate and share results with 20 utilities nationwide

  • Monitor in supply line measuring current and voltage

    Temperature Sensors

    Water flow Sensor

    Customer Load Control Install

  • Plug & play

    Wi-Fi setup

    Account setup

    About the same level of difficulty as internet installation

    SkyCentrics CTA-2045AC (USNAP) module

    AO Smith CTA-2045Port Adaptor

  • 0

    500

    1,000

    1,500

    2,000

    2,500

    3,000

    3,500

    4,000

    4,500

    5,000

    Ener

    gy (

    Wh

    )

    Res-2/2

    Res-1/0

    Res-2/2

    Res-2/3

    Res-2/0

    Res-2/1

    Res-2/1

    Res-2/0

    Res-2/1

    Office

    Averaged380 kWh for

    month

    Averaged310 W

    across peak

  • Load Up

    Load Shed

    Load Up

    Load Shed

    Ensure Comfort

    Recovery

  • 0

    100

    200

    300

    400

    500

    600

    700

    800

    Ene

    rgy

    (Wh

    )

    Controlled Uncontrolled

    14:30 - 15:00 Load Up

    440 Watts

    15:00 - 18:00 Load Shed

    100 Watts

  • 0

    200

    400

    600

    800

    1,000

    1,200

    1,400

    1,600

    Ene

    rgy

    (Wh

    )

    Controlled Uncontrolled

    5:15 – 5:45 Load Up

    480 Watts

    6:00 - 9:00 Load Shed

    400 Watts

    End Shed Rebound

    1,020 Watts

    16:15 - 16:45 Load Up

    250 Watts

    17:00 - 21:00 Load Shed

    210 Watts

    End Shed Rebound

    920 Watts

  • At 380 kWh per month, water heating is just under 30% of residential electric load

    Grid control of water heaters could Shape the load to accommodate more renewable generation

    Be utilized to respond to variations in renewable output

    Reduce peak generation needs

  • 0.00

    0.20

    0.40

    0.60

    0.80

    1.00

    1.20

    Solar: 16%

    Base Generation: 61%

    Dispatched: 23%

  • 0.00

    0.20

    0.40

    0.60

    0.80

    1.00

    1.20

    Base Generation: 61%

    Solar: 20%

    Dispatched: 19%

    25% MoreSolar

    4% Less Peak Load

    8% Less Dispatchablegeneration

  • Questions?