An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying * , Zhang Jiaxun, Liu Dongxiao Beijing Key Laboratory of Space Thermal Control Technology, Beijing Institute of Spacecraft System Engineering (ISSE), Beijing 100094, China Received 20 January 2014; revised 3 June 2014; accepted 8 September 2014 Available online 26 December 2014 KEYWORDS Equivalent ground thermal test; Fluid loop radiator; Normal pressure test; Spacecraft; Thermal control Abstract Thermal vacuum test is widely used for the ground validation of spacecraft thermal con- trol system. However, the conduction and convection can be simulated in normal ground pressure environment completely. By the employment of pumped fluid loops’ thermal control technology on spacecraft, conduction and convection become the main heat transfer behavior between radiator and inside cabin. As long as the heat transfer behavior between radiator and outer space can be equivalently simulated in normal pressure, the thermal vacuum test can be substituted by the nor- mal ground pressure thermal test. In this paper, an equivalent normal pressure thermal test method for the spacecraft single-phase fluid loop radiator is proposed. The heat radiation between radiator and outer space has been equivalently simulated by combination of a group of refrigerators and thermal electrical cooler (TEC) array. By adjusting the heat rejection of each device, the relationship between heat flux and surface temperature of the radiator can be maintained. To verify this method, a validating system has been built up and the experiments have been carried out. The results indi- cate that the proposed equivalent ground thermal test method can simulate the heat rejection per- formance of radiator correctly and the temperature error between in-orbit theory value and experiment result of the radiator is less than 0.5 °C, except for the equipment startup period. This provides a potential method for the thermal test of space systems especially for extra-large space- craft which employs single-phase fluid loop radiator as thermal control approach. ª 2015 Production and hosting by Elsevier Ltd. on behalf of CSAA & BUAA. 1. Introduction Thermal test plays a very important role in the design, evalu- ation, fabrication and integration of the spacecraft thermal control systems. Usually, vacuum thermal balance test is nec- essary to validate the design of thermal control systems and to assess their environmental adaptabilities. According to GJB 1027A-2005 1 and MIL-STD-1540D, 2 this ground based experimental method is very valid and widely accepted; how- ever, it is very expensive and the experimental cost is usually * Corresponding author. Tel.: +86 10 68112212. E-mail addresses: [email protected] (X. Ning), w.yy1986@163. com (Y. Wang). Peer review under responsibility of Editorial Committee of CJA. Production and hosting by Elsevier Chinese Journal of Aeronautics, (2015),28(1): 86–92 Chinese Society of Aeronautics and Astronautics & Beihang University Chinese Journal of Aeronautics [email protected] www.sciencedirect.com http://dx.doi.org/10.1016/j.cja.2014.12.011 1000-9361 ª 2015 Production and hosting by Elsevier Ltd. on behalf of CSAA & BUAA.

An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

Chinese Journal of Aeronautics, (2015),28(1): 86–92

Chinese Society of Aeronautics and Astronautics& Beihang University

Chinese Journal of Aeronautics

[email protected]

An equivalent ground thermal test method

for single-phase fluid loop space radiator

* Corresponding author. Tel.: +86 10 68112212.E-mail addresses: [email protected] (X. Ning), w.yy1986@163.

com (Y. Wang).

Peer review under responsibility of Editorial Committee of CJA.

Production and hosting by Elsevier

http://dx.doi.org/10.1016/j.cja.2014.12.0111000-9361 ª 2015 Production and hosting by Elsevier Ltd. on behalf of CSAA & BUAA.

Ning Xianwen, Wang Yuying *, Zhang Jiaxun, Liu Dongxiao

Beijing Key Laboratory of Space Thermal Control Technology, Beijing Institute of Spacecraft System Engineering (ISSE),Beijing 100094, China

Received 20 January 2014; revised 3 June 2014; accepted 8 September 2014Available online 26 December 2014

KEYWORDS

Equivalent ground thermal

test;

Fluid loop radiator;

Normal pressure test;

Spacecraft;

Thermal control

Abstract Thermal vacuum test is widely used for the ground validation of spacecraft thermal con-

trol system. However, the conduction and convection can be simulated in normal ground pressure

environment completely. By the employment of pumped fluid loops’ thermal control technology on

spacecraft, conduction and convection become the main heat transfer behavior between radiator

and inside cabin. As long as the heat transfer behavior between radiator and outer space can be

equivalently simulated in normal pressure, the thermal vacuum test can be substituted by the nor-

mal ground pressure thermal test. In this paper, an equivalent normal pressure thermal test method

for the spacecraft single-phase fluid loop radiator is proposed. The heat radiation between radiator

and outer space has been equivalently simulated by combination of a group of refrigerators and

thermal electrical cooler (TEC) array. By adjusting the heat rejection of each device, the relationship

between heat flux and surface temperature of the radiator can be maintained. To verify this method,

a validating system has been built up and the experiments have been carried out. The results indi-

cate that the proposed equivalent ground thermal test method can simulate the heat rejection per-

formance of radiator correctly and the temperature error between in-orbit theory value and

experiment result of the radiator is less than 0.5 �C, except for the equipment startup period. This

provides a potential method for the thermal test of space systems especially for extra-large space-

craft which employs single-phase fluid loop radiator as thermal control approach.ª 2015 Production and hosting by Elsevier Ltd. on behalf of CSAA & BUAA.

1. Introduction

Thermal test plays a very important role in the design, evalu-ation, fabrication and integration of the spacecraft thermal

control systems. Usually, vacuum thermal balance test is nec-essary to validate the design of thermal control systems andto assess their environmental adaptabilities. According to

GJB 1027A-20051 and MIL-STD-1540D,2 this ground basedexperimental method is very valid and widely accepted; how-ever, it is very expensive and the experimental cost is usually

Page 2: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

Fig. 1 Schematic diagram of spacecraft fluid loop radiator.

An equivalent ground thermal test method for single-phase fluid loop space radiator 87

more than fifty thousand dollar per day. How to perform theground experiments in a cheaper and more efficient waybecomes necessary for the development of a new thermal con-

trol concept.3–5 The normal pressure ground test is one of themost possible substitutions of vacuum thermal test.

For traditional spacecraft which employs passive thermal

control methods, the major heat transfer approaches are heatconduction and radiation. The exhaust heat is collected byconduction and radiation and leaves the spacecraft radiators

by radiation. Therefore, radiation is the most dominated heattransfer approach which is difficult to be simulated in normalground pressure thermal test.6

As the development of spacecraft active thermal control

technologies, such as pumped fluid loops, spray cooling loopsystem7–9 and heat pipes integrated with variable emittanceradiators10–12, the heat transfer performances become more

and more complex. Among these active thermal control tech-nologies, pumped fluid loops are devices which can provideefficient transfer of a large amount of thermal energy between

several points.6–8 Recently, pumped fluid loops have been usedin many of the space vehicles’ thermal control systems.13–15

Some of the famous missions are the Defense Satellite Pro-

gram, the space shuttle orbiter, Mars Pathfinder, Mars Explo-ration Rover and Mars Science Laboratory.16–20 Forspacecraft which employs pumped fluid loops’ thermal controlsystem, most of the spacecraft waste heat is transferred to radi-

ator by means of forced liquid convection, therefore, heat con-duction and heat convection become the main heat transferapproaches between components and radiators. The heat

transfer behavior between components and radiators can besimulated in normal ground pressure environment directly,because the radiation could be controlled to be less than

10% of the heat transfer. Then, the only problem of normalground pressure test is how to simulate the heat transferbehavior between radiator and outer space.

In this paper, an equivalent ground thermal test method forsingle-phase fluid loop space radiator is considered in normalpressure environment. The major contributions include:

(1) A novel ground-based method which uses hardware-in-loop concept is proposed to simulate the heat rejectionperformance of single-phase fluid loop space radiator.

In this method, an actual cooling system which is servingas the space heat sink is effectively controlled to meet thetheory calculation temperature of radiator so as to sim-

ulate the radiation performance of radiator.(2) A theoretical model of this method is presented and the

net heat transfer between radiator and outer space isassumed as a combination of a steady state heat flux

and a transient heat flux. The theoretical value of eachof heat flux is calculated and used for controlling agroup of refrigerators and thermal electrical cooler

(TEC) array to realize radiators’ temperature trackingduring the whole period.

(3) A validating setup of the proposed ground thermal test

method has been designed, modeled and built. Theexperimental investigations have been performed; theerror between in-orbit theoretical value and experimen-

tal result of the radiator temperature is less than0.5 �C under the most of the considered situations.

The experimental system, mathematical model, discussionof results and major conclusions of this research will bedescribed in the following sections of this paper.

2. Fluid-loop space radiators and their equivalent thermal test

method

2.1. In-orbit mechanism of fluid loop space radiator (FLSR)

A simplified scheme of FLSR which contains k branches offluid loop is shown as Fig. 1. Each branch includes one radia-tor surface; the working fluid is driven to each branch of fluid

loop and a bypass loop by a pump. Denote the nominal tem-perature of the working fluid in the bypass loop as Tr1, Tri thenominal temperature of the working fluid at the inlet of the

radiator branch, and Tri;1;Tri;2; . . . ;Tri;k the nominal tempera-ture at the inlet of each branch. When the working fluid is dri-ven across the radiators, the waste heat carried by the fluid isrejected to the space through radiation. Denote

Tro;1;Tro;2; � � � ;Tro;k as the nominal temperature at the outletof each branch, and Tro the mixed working fluid temperatureat the outlet of all k branches. The radiation heat rejection is

controlled by adjusting the fluid flux through the bypass loopand the radiator branches’ loop. In this way, the working fluidtemperature Tp at the junction outlet point of the bypass loop

and the radiator branches’ loop can be adjusted according tothe devices’ requirements.

2.2. Equivalent ground thermal test method for FLSR at normalpressure

2.2.1. Technical challenges in ground thermal test

In the equivalent ground test of spacecraft thermal control sys-tem, researchers mostly focus on the system’s transient work-ing characteristic, especially for the fluid loop thermal

control system. The key technology of the equivalent thermaltest of fluid loop radiator in 1 atm (1 atm = 1.01325 · 105 Pa)earth environment is the simulation of radiation heat transfer.

As we all know, the inside structure details of the radiator canaffect the fluid loop radiator temperature. Assume we ignorethe inside structure details of the radiator in equivalent groundtest, if the response of the equivalent system could match the

fluid loop radiator’s on-orbit response when they have thesame heat load, then it indicates that the equivalent systemhas the identical state with the space fluid loop radiator.

The spacecraft on-orbit fluid loop radiator system is dis-played in Fig. 1, if the inlet temperatures such as Tri, Tri,1,

Page 3: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

Fig. 2 Equivalent thermal test model of fluid loop radiator in 1 atm earth environment.

88 X. Ning et al.

Tri,2, . . ., Tri,k are identical with the corresponding inlet tem-perature of the equivalent system, then as long as the corre-sponding outlet temperature responses can track the related

on-orbit value correctly, we can conclude that the equivalentthermal test system could simulate the space fluid loopradiator.

Now the only task is to simulate the radiation heat rejectionof on-orbit fluid loop radiator system. To achieve this goal, wepropose an equivalent thermal test model shown in Fig. 2.

As displayed in Fig. 2, we consider simulating the radiationheat rejection of radiator in normal pressure through a groupof refrigerator and TEC array. The equivalent system contains

k branches of fluid loops and each branch of fluid loopexchanges heat with refrigerator through heat exchanger.Because the refrigerator and the heat exchanger have relativelylarge thermal capacity, a TEC array is used to track the on-orbit

transient thermal response precisely. Thus, the outlet tempera-ture T̂ro at the junction point of all k branches of the equivalenttest system can track the on-orbit valueTro through thismethod.

2.2.2. General ideas of equivalent ground thermal test (EGTT)method

As stated above, the key issue of the equivalent thermal test of

fluid loop radiator in normal pressure environment is the sim-ulation of the radiator’s radiation heat transfer. Denote Qs;k asthe space heat flux received by the kth radiator branch and Qr;k

as the heat flux rejected to space through the kth radiatorbranch by means of radiation, then the net heat transferbetween radiator and space is Qs;k �Qr;k.

To describe the ideas and theory of the equivalent simula-tion methods presented in this research clearly, the net heattransfer mentioned above is divided into two parts: steadystate heat flux Qsb;k and transient heat flux Qst;k. Then we get

the equation Qs;k �Qr;k ¼ Qsb;k þQst;k: The two parts repre-sented by Qsb;k and Qst;k can be simulated through the refriger-ator and TEC array separately, which are displayed in the

equivalent simulation system shown in Fig. 2. Refrigeratorhas large thermal capacity and refrigeration quantity, butcould not response quickly, so it is selected to simulate the

steady state heat flux Qsb;k. While TEC array has small thermalcapacity and refrigeration quantity but could respond quickly,so it is selected to simulate the transient state heat flux Qst;k.

That is to say, both refrigerator and TEC array are used tosimulate the net heat transfer between radiator and the spacevacuum Qs;k �Qr;k; namely, Qsb;k þQst;k.

To realize the aim of simulating the ground equivalent ther-mal test of fluid loop radiator, the processes can be summa-rized as the flowchart shown in Fig. 2. Firstly, the working

performance of radiator is numerically calculated and the cal-culated radiator temperature is selected as the reference valueof the simulative fluid loop system. Then, the steady state heat

flux Qsb;k and transient heat flux Qst;k are calculated accordingto the net heat transfer of radiator to outer space. Finally, inthe experiment, the heat reject performance of the ground sim-

ulant equipment is regulated based on the calculated Qsb;k andQst;k to achieve the consistency between test temperature andreference value.

3. Mathematical modeling of EGTT system under normal pressure

The discussion in Section 2 illustrates that the key issue of theground equivalent simulation of the space radiation of radia-

tor is to figure out the steady state heat flux Qsb;k and transientheat flux Qst;k. The details will be discussed in this section.

3.1. Nominal temperature of radiator

As shown in Fig. 2, the space fluid loop radiator contains kbranches of fluid loop and each branch includes one radiator

surface. According to the energy conservation law, thedynamic temperature equation of each branch of fluid loopradiator can be defined as

cr;kmr;k

dTr;k

dt¼ Qi;k þQs;k �Qr;k ð1Þ

where k is the serial number of each radiator branch, cr;k theequivalent specific thermal capacity of the kth radiator branch,

mr,k the equivalent mass of the kth radiator branch, and Tr;k

the average temperature of the kth radiator branch.Qi;k is the heat flux received from fluid loop by the kth radi-

ator branch,

Qi;k ¼ ncp;kGr;kcfðTri;k � Tr;kÞ ð2Þ

Page 4: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

An equivalent ground thermal test method for single-phase fluid loop space radiator 89

where ncp;k is the heat transfer efficiency between fluid loop and

radiator, Gr;k the working fluid flow flux of the kth branch, cfthe working fluid specific thermal capacity, Tr;k the tempera-ture of the kth radiator, and Tri;k the inlet temperature of the

kth fluid loop radiator.Qs;k is the space heat flux received by the kth radiator and is

defined as

Qs;k ¼ Ar;k

X3i¼1

ak;iqk;i ð3Þ

where Ar;k is the radiator area of kth radiator branch, and ak;i

and qk;i are the absorptivity and space heat flux density of thekth radiator branch respectively; the subscripts i = 1, 2, 3

stand for the sun radiation, earth reflection and earth radia-tion.Qr;k is the heat flux rejected to the vacuum space by thekth radiator branch and it is defined as

Qr;k ¼ Ar;ker;krT4r;k ð4Þ

where er;k is the surface emissivity of the kth radiator branchand r the Stefan–Boltzmann constant, r = 5.67 · 10�8 W/

(m2ÆK4).

3.2. Nodical outlet temperature of k radiator branches

According to the definition Eq. (5) of the heat transfer effi-ciency between fluid loop and radiator, we can get the outlettemperature Tro;k of fluid loop in Eq. (6).

ncp;k ¼ ðTri;k � Tro;kÞ=ðTri;k � Tr;kÞ ð5Þ

Tro;k ¼ Tri;k � ncp;kðTri;k � Tr;kÞ ð6Þ

Then we can get the transient energy conservation equationof the temperature of the mixed outlet fluid of all radiator

branches:

mc�cfdTro

dt¼Xki¼1

Gr;icf;iðTro;i � TroÞ ð7Þ

where mc is the total fluid mass of all branches, �cf the average

specific thermal capacity of the fluid loop’s working fluid, cf;ithe working fluid specific heat of the ith radiator branch, Gr;i

the working fluid mass flow rate of the ith radiator branch

and Tro the temperature of the mixed outlet fluid of all kbranches.

3.3. Heat exchange between radiator and space environment

The net heat transfer between radiator and the space vacuumQs;k �Qr;k is the key item in the equivalent thermal test. In thispaper, we divide this item into two parts: the steady state heat

flux Qsb;k and the transient state heat flux Qst;k; then we can get

Qs;k �Qr;k ¼ Qsb;k þQst;k ð8Þ

As the space heat flux received by the radiator changes peri-

odically on orbit, consider the Fourier series of Qs;k and we get

Qs;k ¼1

2A0 þ

X11

AnðhÞ

¼ a0 þX11

ðan cosðnxtÞ þ bn sinðnxtÞÞ ð9Þ

where a0 is constant.

Substituting Eq. (9) into Eq. (8) yields

Qsb;k ¼ Qs;k �Qr;k �Qst;k

¼ a0 þX11

ðan cosðnxtÞ þ bn sinðnxtÞÞ �Qr;k �Qst;k

ð10Þ

Do integral about variable t on both sides of Eq. (10), whichyieldsZ 1

0

Qsb;kdt ¼Z 1

0

a0 þX11

ðan cosðnxtÞ þ bn sinðnxtÞÞ"

�Ar;ker;krT4r;k �Qst;k

idt ð11Þ

or we can getZ 1

0

Qsb;kdt ¼Z 1

0

ða0 �Qav;kÞdt

þZ 1

0

X11

ðan cosðnxtÞ þ bn sinðnxtÞÞ"

þQav;k � Ar;ker;krT4r;k �Qst;k

idt ð12Þ

where Qav;k ¼ Ar;ker;krT4rav;k is the average space heat flux

received by the kth radiator branch in a whole orbit periodand Trav;k is the kth radiator’s average temperature in a whole

orbit period.As

R10ðQav;k � Ar;ker;krT

4r;kÞdt ¼ 0, assign Qst;k ¼

P11

ðan cosðnxtÞ þ bn sinðnxtÞÞ, then Eq. (12) yieldsZ 1

0

Qsb;kdt ¼Z 1

0

ða0 �Qav;kÞdt ð13Þ

or

Qsb;k ¼ a0 �Qav;k ð14Þ

Thus, Eq. (14) gives the steady state heat flux of the kth

radiator branch, which is the reference value of the refrigera-tor’s refrigeration quantity of the equivalent test system;Qsb;k will be figured out in the following context.

3.4. Experimental approaches

According to the equivalent thermal test method shown inFig. 2, before starting the test, the values of Qsb,k and Tro

should be calculated using the methods in Section 3. Duringthe test, firstly, Qsb,k is set as the reference value of the refrig-eration quantity, for the purpose of simulating the steady state

heat flux of the net heat transfer between the fluid loop radia-tor and outer space. Secondly, in order to track the outletmixed fluid temperature T̂ro of space fluid loop radiator, Tro

is set as the reference value of the outlet mixed fluid tempera-ture T̂ro of the equivalent test system.

The main approach of the equivalent thermal test method

presented in this paper is to adjust the refrigerators and TECarray to simulate the two parts of the net heat transfer betweenfluid loop radiator and outer space. In our experiment, therefrigerators are used to simulate the steady state heat flux

and TEC array is used to realize the tracking of Tro. As statedin the last paragraph, Qsb;k is set as the reference value of therefrigeration quantity of the refrigerators. The actual refriger-

ation quantity Q̂sb;k is set as the feedback value of the refriger-ators, which can be calculated as

Page 5: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

Table 1 Parameters of basic heat radiation simulation unit.

Equipment Type Refrigerating output (W) Quantity

Refrigerator Anges AC-3L 2100 2

TEC TEC1-4905 15.8 1

Heat exchanger B3-026-10D 1000 2

Table 2 Design parameters of the satellite.

Parameter Value

Orbit type Circle

Orbit height (km) 800

Orbit inclination angle (�) 63.41

Orbit period (min) 101

+X surface area (m2) 2.6

�X surface area (m2) 1.4

Low case heat load (W) 300

90 X. Ning et al.

Q̂sb;k ¼ Gfr;kcp;frðTfro;k � Tfri;kÞ ð15Þ

where Gfr,k, cp,fr, Tfri,k and Tfro,k are the working fluid massflux, specific heat, the working fluid inlet temperature and

the outlet temperature of the kth refrigerator branch respec-tively. The values of the temperature and working fluid massflux in Eq. (15) can be metered through the temperature sensor

and mass flux meter during the experiment.

4. Experimental validation of the EGTT method

4.1. Experimental setup and technical performances

To validate the feasibility of this test method, an equivalenttest system is set up (see Fig. 3), which consists of spacecraftphysical simulation unit, the basic radiation heat transfer sim-

ulation unit and EGTT control system. Among them, space-craft physical simulation unit is used to simulate thespacecraft’s inside cabin heat transfer characteristics, the basicheat radiation simulation unit is used to simulate the space-

craft’s radiation heat sink and the EGTT control system isthe calculation and control center of this test system. The basicheat radiation simulation unit include two refrigerators, two

heat exchangers and one TEC to simulate a spacecraft contain-

Fig. 3 Schematic diagram o

ing two branches radiator. The details of basic heat radiationsimulation unit are displayed in Table 1.

During the experiment, the PT100 platinum resistance ther-

mal sensors with measurement accuracy ±0.1 �C are used tomonitor the temperatures of key points in the system. Turbine

f equivalent test system.

Hot case heat load (W) 800

Page 6: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

An equivalent ground thermal test method for single-phase fluid loop space radiator 91

flow meters with type of LWGY DN4 are selected to recordthe working fluid volume flow rate in the loops, the measure-ment accuracy of which is ±0.5%, with a measuring range

of 0.04–0.25 m3/h. The accuracy of heat load simulation sys-tem is ±0.1 W.

4.2. Parameters and orbit environment of the satellite investigated

In the experiment, an inclined-orbit hexahedral satellite is sim-ulated. The orbit height of the inclined-orbit hexahedral satel-

lite is 800 km, orbit inclination angle b = 0�, the orbit period is101 min (with 35 min in the earth’s shadow, 66 min can receivethe sunshine). The detailed parameters of the satellite are

shown in Table 2.The heat load variation of the devices during the two-

orbit period is shown in Fig. 4. When the satellite is in theearth’s shadow, the devices’ minimum heat load is 300 W,

and when it moves to the sunshine, the devices’ maximumheat load is 800 W. The satellite’s fluid loop thermal controlsystem includes two radiator surfaces located on the ±X side

of the satellite respectively. The variation of the spaceradiation heat flux received by the two radiators is shownin Fig. 5.

Fig. 4 Heat load variation of the devices during the two-orbit

period.

Fig. 5 Space heat flux absorbed by radiator.

4.3. Results and discussion

Ground experiments are carried out to validate the equivalentthermal test method proposed in this paper. In this experiment,the fluid loop thermal control system of a satellite with param-

eters shown in Table 2 is simulated. There are two radiators inthe thermal control system, and two branches of fluid loop sys-tem transfer the waste heat of devices to the radiators.

The experimental results of three orbit periods of the satel-

lite are shown in Figs. 6–8 and illustrations from the experi-ment results are discussed as follows.

Figs. 6 and 7 display the outlet working fluid temperature

of radiator 1 and radiator 2. The data shows that the errorbetween T̂ro;1 and Tro;1, Tro;2 and T̂ro;2 are approximately 3 �Cand 2 �C respectively, when the radiator’s temperature reaches

peak and falls down to valley value. While in other cases theerror decreases to 0.5 �C. That is because the temperaturesof the two branches are adjusted only using the steady state

on-orbit value as the controller’s reference value, thereforethe experimental values could not track the calculated on-orbitvalue very precisely.

Fig. 8 displays the mixed working fluid temperature (T̂ro

and Tro) of radiator 1 and radiator 2. The experimental resultis identical with the calculated theory value, and the errorbetween the theoretical value and the experimental result of

the target temperature is less than 0.5 �C except for the startupperiod in the first 500 s.

This indicates that the track of transient heat flux by TEC

array is essential. After transient heat flux is considered, theerror between on-orbit value and experimental value decreases

Fig. 6 Outlet fluid temperature of radiator 1 (T̂ro;1 and Tro;1).

Fig. 7 Outlet fluid temperature of radiator 2 (T̂ro;2 and Tro;2).

Page 7: An equivalent ground thermal test method for single-phase ... · An equivalent ground thermal test method for single-phase fluid loop space radiator Ning Xianwen, Wang Yuying *,

Fig. 8 Mixed working fluid temperature (T̂ro and Tro) of

radiator 1 and radiator 2.

92 X. Ning et al.

by 80%. The heat radiation of space radiator can be preciselysimulated by the simulation of Qsb;k and Qst;k, through control-ling the refrigerators and TEC array using the theoretical val-

ues of Qsb;k and Qst;k as the reference value. The resultsillustrate that it is reasonable of using the equivalent thermaltest method to validate the space radiation performance of

the fluid loop radiator thermal control system.

5. Conclusions

We propose an equivalent ground thermal test method toreflect the heat rejection performances of fluid loop space radi-ator, which is necessary for the large spacecraft such as space

station and deep space exploration vehicles. Both theoreticalapproach and experimental setup have been discussed indetailed. The experimental results argue that the error between

the theoretical and the experimental values is less than 0.5 �Cexcept for the equipment startup period.

This suggests that the proposed equivalent ground thermaltest method can be considered as a potential effective way to

evaluate the working performance and environmental adapta-bilities of fluid-loop space radiator which may be involved inmany advanced spacecraft thermal control systems. In the

future, the equivalent ground thermal test method can beextended to spacecraft thermal balance test, it will save a lotof scientific research funds, and shorten the project develop-

ment schedule.

Acknowledgments

The authors thank the anonymous reviewers for their criticaland constructive review of the manuscript. This study wasco-supported by the National Natural Science Foundation of

China (No. 11472040).

References

1. GJB 1027A-2005 Test requirements for launch, upper-stage, and

space vehicles; 2005.1.

2. Department of Defense Standard Practice. Product verification

requirements for launch, upper stage, and space vehicles, MIL-

STD-1540D. 1999.

3. Li YZ, Lee KM, Wang J. Analysis and control of equivalent

physical simulator for nanosatellite space radiator. IEEE/ASME

Trans Mech 2010;15(1):79–87.

4. Marce JL, Merlet J, Yannick C, Poulain B, Gayrard J. A new

method for thermal vacuum tests telecommunication spacecraft-

the simulation of thermal sink. Proceedings of 20th space simula-

tion conference on the changing testing paradigm; 1998. p. 189–94.

5. Asteggiano C, Guglielmo C, Sacchi E, Tessarin F, Williams T,

Borde F, et al. The I/R thermal balance test of radarsat-2:

approach to verification/correlation. Proceedings of 35th interna-

tional conference on environmental systems and 8th European

symposium on space environmental control systems; 2005.

6. Gilmore DG. Spacecraft thermal control handbook. 2nd ed. Cal-

ifornia: The Aerospace Press El Segundo; 2002, p. 405–68.

7. Min GR, Guo S. Spacecraft thermal control. 2nd ed. Beijing: Sci-

ence Press; 1998, p. 216–21 [Chinese].

8. Hou ZQ, Hu JG. Spacecraft thermal control technology-theory and

application. Beijing: China Science Technology Press; 2007, p.

242–53.

9. Li YZ, Li MM, Lee KM. A dual-driven intelligent combination

control of heat pipe space cooling system. Chin J Aeronaut

2012;25(4):566–74.

10. Wang J, Li YZ, Wang J. Transient performance and intelligent

combination control of a novel spray cooling loop system. Chin J

Aeronaut 2013;26(5):1173–81.

11. Osiander R, Firebaugh SL, Champion JL, Farrar D, Darrin

MAG. Micro electro mechanical devices for satellite thermal

control. IEEE Sens J 2004;4(4):525–31.

12. Farrar D, Schneider W, Osiander R, Champion JL, Darrin AG,

Douglas D, et al. Controlling variable emittance (MEMS) coatings

for space applications. Proceedings of the 8th intersociety confer-

ence on thermal and thermos mechanical phenomena in electronic

systems; 2002. p. 1020–4.

13. Birur GC. JPL advanced thermal control technology roadmap.

Pasadena, CA: Jet Propulsion Laboratory of California Institute

of Technology; 2005.

14. Shen F, Drolen B, Prabhu J, Harper L, Eichinger E, Nguyen CL.

Life mechanical fluid pump for space applications. Reston: AIAA;

2005. Report No.: AIAA-2005-0273.

15. Matthijssen R, van Put P, van der List MCAM. Development of an

advanced mechanically pumped fluid loop for thermal control of

large future telecommunication platforms. De Wijper: Bradford

Engineering; 2005.

16. Bhandari P, Birur GC. Long term life testing of a mechanically

pumped cooled loop for spacecraft thermal control. Reston:

AIAA; 1997. Report No.: AIAA-1997-2470.

17. Thunnissen DP, Tsuyuki GT. Margin determination in the design

and development of a thermal control system. 2004. Report No.:

SAE 04ICES-239.

18. Bhandari P, Dudik B, Birur G, Bame D. Mars science laboratory

launch pad thermal control. Proceedings of the 41st international

conference on environmental systems; 2011 Jul 17–21; Portland,

Oregon. Reston: AIAA; 2011.

19. Paris AD, Kelly FP, Kempenaar JE, Novak KS. In-flight

performance of the Mars Science Laboratory spacecraft cruise

phase thermal control systems. Proceedings of the 42nd interna-

tional conference on environmental systems; 2012 Jul 12–19; San

Diego, California. Reston: AIAA; 2012.

20. Birur GC, Bhandari P, Bame D, Karlmann P, Mastropietro AJ,

Liu YM, et al. From concept to flight: an active fluid loop based

thermal control system for Mars Science Laboratory Rover.

Proceedings of the 42nd international conference on environmental

systems; 2012 Jul 12–19; San Diego, California. Reston: AIAA;

2012.

Ning Xianwen received the Ph.D. degree from Beihang University in

2006, and then became a spacecraft thermal engineer. His main

research interest is spacecraft thermal control technology.