Upload
georgina-pope
View
226
Download
3
Tags:
Embed Size (px)
Citation preview
ANALYST 4.XXPC Interface LogbookTutorial for Windows 95/98/NTME/2000 & XP
Cochran Undersea Technology a division of Cochran Consulting, Inc.Copyright 1999 - 2006 All rights reserved, Protected under one or more
Patents, Patents Pending, or Trademarks.
Click the left mouse button to proceed and follow the instructions given.
Cochran Dive Computer, Analyst, Logbook relationship overview
Click left mouse button to proceed.
Dive StatisticsProfile Graphs
etc.For dives 1 to n
Dive Computer
LogbookFor dives 1 to n
CochranFTP Site
PC Hard Drive
DefaultFile
DANFTP Site
Analyst .can File
Dive Site(s)Apps Folder
User(s)Apps Folder
The Blending Wizard is designed and intended to be used onlyby certified Nitrox gas blenders for the sole purpose of blending
Air/Oxygen mixtures.The Blending Wizard feature is only available in
Specific Editions of ANALYST.
This is the opening ANALYST Window.
The File Button allows creating, viewing, deleting files and checking
for Analyst updates.
Statistics Button shows Dive Totals,Dive Beginning, Dive Ending, Dive Config,
and other Dive Statistics.Profiles Button shows many
extensive Profile Graphs.
The Owner button allows the storage and retrieval of the Dive computer Owners Information,
which the Dealer has stored in the Dive ComputerTissue Loading Button shows Dive Beginning,
Dive ending, and Current Tissue Loading Bar Graphs.
The Tissue Loading feature is only available inspecific Editions of ANALYST.
Configure Button allows the diver to Configure the Dive Computer specifically to
their style and Diving requirements.
Parametric Cloning Button Transfers Parameters from one Cochran Dive Computer another. This
button appears on Several Toolbars.Parametric Cloning will be covered in a separate Tutorial.
The Parametric Cloning feature is only available inspecific Editions of ANALYST.
Dive Planning and Simulation Wizard feature is only available in
specific Editions of ANALYST.
Logbook Button invokes the DAN Compatible Divers Logbook Database. Also allows the storage and retrieval of
the Dive computer users Personal, Medical and PreDive information.
On-line, context-sensitive Help! Click on the ‘?’, thenclick on the object or item for which help is needed.
Click left mouse button to proceed.
Click on the File Button.
Acquire dive computer datato a new or existing file
View an existing dive computer file Delete an existing dive computer file Analyst can check via the internet tosee if there are any program updates.
On-line, context-sensitive Help! Click on the ‘?’, thenclick on the object or item for which help is needed.
Click on the Acquire Button.
Attach the dive computer to the Analyst interface cable as shown.
Click on OK.
Click on Save.
Visual representation of the type ofunit being viewed/acquired.
The Analyst will prepare to save the computer file under a name based on the unit serial number. The file’s
name and/or location may be changed at this time.
The progress bar will show that the Analyst is acquiring the dive computer information.
This may take longer if many dives have been made since last acquiring the dive computer.
Click left mouse button to proceed.
After Acquiring the information, the main window will be shown.
Clicking on one of the buttons will show the specified data.
Click left mouse button to proceed.
Logbook Button invokes the DAN Compatible Divers Logbook Database.Also allows the storage and retrieval of
the Dive computer User’s Personal, Medical and PreDive information.
Click on Logbook Button.
Separate page for User Personal DataSeparate page for User Medical DataSeparate page for User PreDive Data
Click left mouse button to proceed.
Data In Blue Are Required by DAN (Divers Alert Network)Only if the dives are to be exported to Dan
Separate Logbook pages for 48 Hours DataSeparate Logbook pages for PostDive DataSeparate Logbook pages for DiveSite Data
Erase all data on this Page.Save ‘Put’ Data
Print Option Button for Printing, Printer Setup,and capturing the screen
to the clipboard.
Clicking the Back button returns the diver to the Main Analyst Window.
Retrieve ‘Get’ DataDive Number Logbook page
Click on the Print Button
Print Screen as shown
Click left mouse button to proceed.
Printer configuration, select multiple copies.
Automatically Send this ‘.can’ file to CochranSend current page as shown to the P.C.’s
Clipboard
Various Entries have drop down menusGray’d entries are filled in automatically
And can not be changed
Click left mouse button to proceed.
User Personal Data Sheet completed
Click on the User Medical Tab
Various Entries have drop down menusUser Medical Data Sheet completed
Click on the User PreDive Tab
Click left mouse button to proceed.
Various Entries have drop down menus
Click left mouse button to proceed.
User PreDive Data Sheet completed
Click on the PUT Button
Next let’s store the User Data
Logbook data Put to the Selected Dive of the Analyst File.
Logbook data Put to the Default Area of the file can be recalled to prefillThe Logbook pages for other dives.
User data Put to the Apps User folder in the Analyst directory
can be recalled to prefill theUser Logbook pages for other dives.
DiveSite data Put to the Apps Sites folder in the Analyst directory can be recalled to prefill the DiveSite Logbook pages for other dives.
User data Put (stored) in the Dive Computer – User Data can be
recalled to fill in the User Logbook pages for other dives.
Click on Put User Data to File in the Apps User Folder
Next let’s Name this User Mike113Click on Save
Click on the PUT Button
User Data is now stored in the Apps User FolderNext let’s store it to the Dive Computer
User Data can not be stored in older Cochran Dive Computers.
Click on Put User Data into the Attached Dive Computer
The progress bar will show that the User DataIs being stored “Put” into the dive computer
User Data is now Stored in the dive computer
Now for the DiveSite Data
Click on the DiveSite Tab
Various Entries have drop down menus
Click left mouse button to proceed.
Click on the PUT Button
With the DiveSite Data Filled inNext let’s store it to the Sites folder
DiveSite data Put to the Apps Sites folder in the Analyst directory can be recalled to prefill the DiveSite Logbook pages for other dives.
Click on Put Dive Site Data into the Apps Sites folder
Let’s Name the Dive Site “Lake Someplace”Click on Save
Dive Site Data is now Stored in the Sites folder
Click on the PostDive Tab
Various Entries have drop down menus
Click left mouse button to proceed.
With the Post Dive Data Filled inNow let’s do the 48 Hours Report
Click on the 48 Hours Tab
Additional Information will be requiredIf the answer is YES, these will appear automatically
Select Were you Exposed
The 48 Hour Report Must be Completed 48 Hours After the Last Dive or Flight
Without this information the DAN file is useless
Select No
Select Any Unusual symptoms
Select No
Select Were You Treated
Select No
The logbook for this dive is now completeNow see what happens to the 48 Hour Report
when exposure to Altitude is answered Yes
Click left mouse button to proceed.
Additional Information will be requiredIf the answer is YES, these will appear automatically
Select Were you Exposed
Select Yes
The 48 Hour Report, when exposure to Altitude is answered Yes, now has addition
Data fields
Several fields have drop down menusThe rest are free form data entry
The Exposure section is now complete.Now see what happens to the 48 Hour Report
when Unusual symptoms is answered Yes.
Select Any Unusual symptoms
Select Yes
The Unusual symptoms section now hasA free form data input field
The Unusual Symptoms section is now complete.Now see what happens to the 48 Hour Report
when ‘Were you treated is answered Yes.
Select Were you treated
Select Yes
The Were you Treated section now containsSeveral free form data fields
The ‘Were you Treated’ section andthe 48 Hour Report are now complete.
Now this dives log book needs to be stored.
Click on the PUT Button
Logbook data Put to the Default Area of the file can be recalled to prefillThe Logbook pages for other dives.
Select Put Logbook toSelected Dive in File.
The Logbook for this dive is now stored in the Analyst .CAN file of this Dive ComputerNow let’s fill in dive # 495 logbook using the
data files that we stored
Click left mouse button to proceed.
Click on the GET Button
Click left mouse button to proceed.
Retrieve Logbook Data forthis dive from the file
Retrieve Logbook Data fromthe Default file sectionRetrieve User Data from
the Apps User Folder
Retrieve Dive Site Data fromthe Apps Sites Folder
Retrieve User Data fromthe Dive Computer
Retrieve Owner Data fromthe Dive Computer
Retrieve relevant Dive Computer Data from Analyst File
Select Get User Data FromFile in Apps User Folder.
Select Mike113 From theFile in Apps User Folder.
User Mike113 hasbeen selected
Click OK
User Mike113’s Personal data now is filled in for dive # 495’s logbook
Click left mouse button to proceed.
User Mike113’s Medical data is now also filled in for dive # 495’s logbook
Click left mouse button to proceed.
User Mike113’s PreDive data is now also filled in for dive # 495’s logbook
Click left mouse button to proceed.
Now to fill in the Dive Site Data
Click on the GET Button
Select Get Dive Site Data FromFile in Apps Sites Folder.
Select LakesomePlace2 From the File in Apps Sites Folder.
Dive Site Someplace Else 2 has been selected
Click OK
Dive Site data is now filled in for dive # 495’s logbook
Click left mouse button to proceed.
Now to update the dive data for dive 495
Click on the GET Button
Select Get relevant Dive ComputerData From Analyst File.
Dive Site fields are now updated with dive # 495’s dive data
Click left mouse button to proceed.
Now that the Logbook Data is completed How do we send the file(s) to DANClick on the DAN Button
The diver can send the current dive
How do we send the file(s) to DAN:
The diver can send all dives between two dive numbersThe diver can send all dives
between two datesThe diver can send all dives with the same Family NameThe diver can send all dives
that have been tagged
Lets send this Dive Only to DAN
Click on the Sort Button
Click left mouse button to proceed.
The diver can send all unsent dives
Analyst Sorted the file and Found 1 dive that matched
the selected criteria
Click OK
Click on the Send Button
Permits the diver to markthese dives as being sent to DAN
Click left mouse button to proceed.
Lets the Diver send the file Directly to DAN
Click left mouse button to proceed.
The File has been sent to DAN
Click left mouse button to proceed.
Sort By Unsent Dives,Sort Between Two Dive Number,
Sort Between Two Dive Dates,Sort by Divers Family Name
Are self explanatoryBut what are Tagged Dives?
Lets Find Out!
Click on the Cancel Button
Dive Not Tagged To Go to DAN
Click on the Tag Button
Tags a Dive To Go to DANDives do not have to be
in a continuous sequence Lets Tag this Dive
Click left mouse button to proceed.
Dive Tagged To Go to DAN Allows the Diver to Manual Erase Tags
Click left mouse button to proceed.
This Concludes the Analyst Logbook Tutorial
Click left mouse button to proceed.
Now for a review of the relationship between User Information, the Logbook and the Analyst .can file
The User Information is Put (stored) in the dive computer by the User of the dive computer. This Information can also be Put intothe Analyst file and associated with specific dives. This Information can also be Put into the Apps User file and associated with specific dives. Multiple User’s data can be stored in the Apps User Folder.
The Logbook Information is Put (stored) in the Analyst .can fileAnd is associated with specific dives by the User of the dive computer.
Click left mouse button to proceed.
Visit our website at www.divecochran.com
to learn more about DAN and
Project Dive Exploration
Click left mouse button to proceed.
Cochran Dive Computers are one of the few that can wear this decal. Cochran Undersea Technology has teamed with Divers Alert Network (DAN) to build a
safer tomorrow for all Divers.
Take part in the largest “Dive” Data collection ever!Use Analyst 4.XX to send files to DAN for thecontinued research into recreational diving and DCS.
Diamond Sponsor
Be a partner in tomorrows safety with DAN.
Click left mouse button to proceed.
To stay up to date on changes, news and FAQs from Cochran Undersea Technology visit our website
www.divecochran.com
For Product Support, email us at [email protected]
For Customer Service, email us at [email protected]
or call Weekdays972.644.6284
orToll Free in USA1.800.856.3483
9:00 AM to 6:00 PM Central Time
Click left mouse button to proceed.
CochranUndersea
Technologywww.divecochran.com
Click here to proceed or Left Mouse Click to Exit.