46
Analyte Name CAS Number Fee Per Sample* Method Method Link* Technique Media* Flow Rate (Lpm)* Air Volume (L)* RL (µg)* Compatibility Code Notes* Acenaphthene also see PAH scans 83-32-9 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap. Acenaphthylene also see PAH scans 208-96-8 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap. Acetaldehyde also see aldehyde scans 75-07-0 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.1-1.5 1-15 0.5 5 Store cold; flow rate/volume from NIOSH 2016. Acetaldehyde also see aldehyde scans 75-07-0 OSHA 68 GC/NPD 0.05 3 2 19 Acetic acid 64-19-7 OSHA PV 2119 IC CT (SKC 226-01) 0.2 48 6 - Cold shipment not required, but store cold before shipping. Acetic acid 64-19-7 NIOSH 1603 GC/FID CT (SKC 226-01) 0.01-1 20-300 20 - Call laboratory before sampling – reagent needed for analysis not available when this document was published. Acetic acid 64-19-7 NIOSH 2011 IC SG-T12 (SKC 226-10-03 or ORBO 53) 0.05-0.2 1-24 6 35 Acetoin 513-86-0 OSHA 1013 GC/FID SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 9 (3 for STEL) 1 42 Protect samples from light during and after sampling, using tube holders, aluminum foil, or other means. Store cold. Acetoin 513-86-0 OSHA 1012 GC/ECD SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 9 (3 for STEL) 0.05 41 Protect samples from light during and after sampling, using tube holders, aluminum foil, or other means. Store cold. Acetone 67-64-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 0.5-3 3 1 Acetonitrile 75-05-8 NIOSH 1606 GC/FID CT (SKC 226-09) 0.01-0.2 3-25 4 17 Acetonitrile 75-05-8 OSHA 37 GC/NPD CT (SKC 226-01) 0.2 8-48 1 17 Acrolein 107-02-8 NIOSH 2501 GC/NPD 0.01-1.0 8-48 2 19 Acrolein 107-02-8 OSHA 52 GC/NPD 0.1 48 2 19 Acrylamide 79-06-1 OSHA PV 2004 HPLC OVS-7 (SKC 226-57) 1 120 0.5 - Preferred method Acrylamide 79-06-1 OSHA 21 GC/NPD GFF-13mm / SG (SKC 226-10 or 226-15) 1 120 0.4 - Sampling train; store cold; transfer completed sample to 1ml glass vial w/methanol Acrylic acid 79-10-7 OSHA PV 2005 HPLC Anasorb 708 (2 tubes) (SKC 226-30-08) 0.1 24 2 - Store cold; protect samples from light; separate tubes after sampling Acrylic acid 79-10-7 OSHA 28 HPLC Anasorb 708 (2 tubes) (SKC 226-30-08) 0.1 24 2 - Store cold; protect samples from light; separate tubes after sampling Acrylonitrile 107-13-1 NIOSH 1604 GC/FID CT (SKC 226-01) 0.01-0.2 3.5-20 3 1 Acrylonitrile 107-13-1 OSHA 37 GC/NPD CT (SKC 226-01) 0.2 20 1 - Aldrin 309-00-2 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.05 29 Store cold; wrap in foil for shipment; holding time is 7 days Alkaline dust - NIOSH 7401 Wet Chem PTFE-1µm 1.0-4.0 70-1000 60 20 Allyl alcohol 107-18-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1 Note OSHA 7 is analytically equivalent to NIOSH method. Allyl chloride 107-05-1 NIOSH 1000 GC/FID CT (SKC 226-01) 0.01-1.0 15-100 3 1 Aluminum 7429-90-5 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-400 1 7 Cannot use this method for aluminum oxide –see aluminum oxide. Do not exceed 2 mg of total dust on filter. Aluminum oxide 1344-28-1 NIOSH 0500 Gravimetric PVC 1.5–2.0 25-1000 50 - Cannot be done as aluminum. 141-43-5 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-0.2 4-24 1 - Keep samples frozen. See method if long-term storage (more than 2 wks) required. Ammonia 7664-41-7 NIOSH 6016 IC SG-T3 (SKC 226-10-06) 0.1-0.5 0.1-96 10 - Formerly cited as NIOSH S-347, 2nd Ed. (same media). Can use MCE as prefilter, if concerned w/ particulate interferences. Ammonia 7664-41-7 OSHA ID-164 Wet Chem 0.1N H2SO4 (FGB) 1 120 50 - Ship samples to lab in glass vials w/ Teflon-lined caps. Amyl acetate,n- 628-63-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1 Aniline 62-53-3 NIOSH 2002 GC/FID SG (SKC 226-10 or 226-15) 0.02-0.2 5-30 2 18 Anthracene also see PAH scans 120-12-7 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap. Anthracene also see PAH scans 120-12-7 OSHA 58 HPLC GFF-37mm 2 960 3 6 Protect from light; wipe inside of cassette with filter, and transfer filter to vial w/ teflon lined cap Antimony 7440-36-0 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-400 1 7 Do not exceed 2 mg of total dust on filter. [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/5506.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/5506.pdf) [View] (http://www3.epa.gov/ttnamti1/files/ambient/airtox/to- 11ar.pdf) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 68/org068.pdf) XAD2-T1; for TWA use SKC 226-117 or ORBO 24; for STEL use SKC 226- 54 [View] (https://www.osha.gov/dts/sltc/methods/partial/pv211 9/pv2119.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/1603.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/2011.pdf) [View] (https://www.osha.gov/dts/sltc/methods/validated/10 13/1013.pdf) [View] (https://www.osha.gov/dts/sltc/methods/validated/10 12/1012.pdf) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 07/org007.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/1606.pdf) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 37/org037.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/2501.pdf) XAD2-T1; for TWA use SKC 226-117 or ORBO 24; for STEL use SKC 226- 54 [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 52/org052.html) XAD2-T1; for TWA use SKC 226-117 or ORBO 24; for STEL use SKC 226- 54 [View] (https://www.osha.gov/dts/sltc/methods/partial/pv200 4/2004.html) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 21/org021.html) [View] (https://www.osha.gov/dts/sltc/methods/partial/pv200 5/2005.html) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 28/org028.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/1604.pdf) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 37/org037.html) [View] (http://www3.epa.gov/ttnamti1/files/ambient/airtox/to- 10ar.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/7401.pdf) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 07/org007.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/1000.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/7303.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/0500.pdf) Aminoethanol, 2 [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/2007.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/6016.pdf) [View] (https://www.osha.gov/dts/sltc/methods/partial/id164/ id164.html) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 07/org007.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/2002.pdf) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/5506.pdf) [View] (https://www.osha.gov/dts/sltc/methods/organic/org0 58/org058.html) [View](http://www.cdc.gov/niosh/docs/2003- 154/pdfs/7303.pdf)

Analyte Name CAS Number Fee Per Sample* Method … · Acenaphthene also see PAH scans 83-32-9 NIOSH 5506 HPLC PTFE-2µm / XAD-2 ... Aluminum oxide 1344-28-1 NIOSH 0500 Gravimetric

Embed Size (px)

Citation preview

Analyte Name CAS Number Fee Per Sample* Method Method Link* Technique Media* Flow Rate (Lpm)* Air Volume (L)* RL (µg)* Compatibility Code Notes*

Acenaphthene also see PAH scans 83-32-9 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Acenaphthylene also see PAH scans 208-96-8 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Acetaldehyde also see aldehyde scans 75-07-0 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.1-1.5 1-15 0.5 5 Store cold; flow rate/volume from NIOSH 2016.

Acetaldehyde also see aldehyde scans 75-07-0 OSHA 68 GC/NPD 0.05 3 2 19

Acetic acid 64-19-7 OSHA PV 2119 IC CT (SKC 226-01) 0.2 48 6 - Cold shipment not required, but store cold before shipping.

Acetic acid 64-19-7 NIOSH 1603 GC/FID CT (SKC 226-01) 0.01-1 20-300 20 - Call laboratory before sampling – reagent needed for analysis not available when this document was published.

Acetic acid 64-19-7 NIOSH 2011 IC SG-T12 (SKC 226-10-03 or ORBO 53) 0.05-0.2 1-24 6 35

Acetoin 513-86-0 OSHA 1013 GC/FID SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 9 (3 for STEL) 1 42 Protect samples from light during and after sampling, using tube holders, aluminum foil, or other means. Store cold.

Acetoin 513-86-0 OSHA 1012 GC/ECD SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 9 (3 for STEL) 0.05 41 Protect samples from light during and after sampling, using tube holders, aluminum foil, or other means. Store cold.

Acetone 67-64-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 0.5-3 3 1

Acetonitrile 75-05-8 NIOSH 1606 GC/FID CT (SKC 226-09) 0.01-0.2 3-25 4 17

Acetonitrile 75-05-8 OSHA 37 GC/NPD CT (SKC 226-01) 0.2 8-48 1 17

Acrolein 107-02-8 NIOSH 2501 GC/NPD 0.01-1.0 8-48 2 19

Acrolein 107-02-8 OSHA 52 GC/NPD 0.1 48 2 19

Acrylamide 79-06-1 OSHA PV 2004 HPLC OVS-7 (SKC 226-57) 1 120 0.5 - Preferred method

Acrylamide 79-06-1 OSHA 21 GC/NPD GFF-13mm / SG (SKC 226-10 or 226-15) 1 120 0.4 - Sampling train; store cold; transfer completed sample to 1ml glass vial w/methanol

Acrylic acid 79-10-7 OSHA PV 2005 HPLC Anasorb 708 (2 tubes) (SKC 226-30-08) 0.1 24 2 - Store cold; protect samples from light; separate tubes after sampling

Acrylic acid 79-10-7 OSHA 28 HPLC Anasorb 708 (2 tubes) (SKC 226-30-08) 0.1 24 2 - Store cold; protect samples from light; separate tubes after sampling

Acrylonitrile 107-13-1 NIOSH 1604 GC/FID CT (SKC 226-01) 0.01-0.2 3.5-20 3 1

Acrylonitrile 107-13-1 OSHA 37 GC/NPD CT (SKC 226-01) 0.2 20 1 -

Aldrin 309-00-2 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.05 29 Store cold; wrap in foil for shipment; holding time is 7 days

Alkaline dust - NIOSH 7401 Wet Chem PTFE-1µm 1.0-4.0 70-1000 60 20

Allyl alcohol 107-18-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1 Note OSHA 7 is analytically equivalent to NIOSH method.

Allyl chloride 107-05-1 NIOSH 1000 GC/FID CT (SKC 226-01) 0.01-1.0 15-100 3 1

Aluminum 7429-90-5 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-400 1 7 Cannot use this method for aluminum oxide –see aluminum oxide. Do not exceed 2 mg of total dust on filter.

Aluminum oxide 1344-28-1 NIOSH 0500 Gravimetric PVC 1.5–2.0 25-1000 50 - Cannot be done as aluminum.

141-43-5 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-0.2 4-24 1 - Keep samples frozen. See method if long-term storage (more than 2 wks) required.

Ammonia 7664-41-7 NIOSH 6016 IC SG-T3 (SKC 226-10-06) 0.1-0.5 0.1-96 10 - Formerly cited as NIOSH S-347, 2nd Ed. (same media). Can use MCE as prefilter, if concerned w/ particulate interferences.

Ammonia 7664-41-7 OSHA ID-164 Wet Chem 0.1N H2SO4 (FGB) 1 120 50 - Ship samples to lab in glass vials w/ Teflon-lined caps.

Amyl acetate,n- 628-63-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Aniline 62-53-3 NIOSH 2002 GC/FID SG (SKC 226-10 or 226-15) 0.02-0.2 5-30 2 18

Anthracene also see PAH scans 120-12-7 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Anthracene also see PAH scans 120-12-7 OSHA 58 HPLC GFF-37mm 2 960 3 6 Protect from light; wipe inside of cassette with filter, and transfer filter to vial w/ teflon lined cap

Antimony 7440-36-0 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-400 1 7 Do not exceed 2 mg of total dust on filter.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

68/org068.pdf)XAD2-T1; for TWA use SKC 226-117 or ORBO 24; for STEL use SKC 226-

54

[View](https://www.osha.gov/dts/sltc/methods/partial/pv211

9/pv2119.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1603.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2011.pdf)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

13/1013.pdf)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

12/1012.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1606.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

37/org037.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2501.pdf)

XAD2-T1; for TWA use SKC 226-117 or ORBO 24; for STEL use SKC 226-54

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

52/org052.html)

XAD2-T1; for TWA use SKC 226-117 or ORBO 24; for STEL use SKC 226-54

[View](https://www.osha.gov/dts/sltc/methods/partial/pv200

4/2004.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

21/org021.html)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv200

5/2005.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

28/org028.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1604.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

37/org037.html)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

10ar.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7401.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1000.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

Aminoethanol, 2 [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6016.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/id164/

id164.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2002.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

Antimony 7440-36-0 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Arsenic 7440-38-2 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-2000 1 7 Do not exceed 2 mg of total dust on filter.

Arsenic trioxide 1327-53-3 NIOSH 7901 ICP MCE – treated (see notes, at right) 1.0 – 3.0 30-1000 0.01 -

Arsine (as Arsenic) 7784-42-1 NIOSH 6001 ICP/MS CT (SKC 226-01) 0.01-0.2 1.0-10 0.02 -

Asbestos 1332-21-4 NIOSH 7400A PCM TEM MCE-25 mm 0.5-16 400-5000 5 f/mm2 21 Both methods: Sample open-faced.

Asbestos 1332-21-4 NIOSH 7402 PCM TEM MCE-25 mm 0.5-16 400-5000 2 f/mm2 21 Both methods: Sample open-faced.

8052-42-4 OSHA 58 -

Barium 7440-39-3 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-400 1 7 Do not exceed 2 mg of total dust on filter.

Benzaldehyde also see aldehyde scans 100-52-7 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.1-1.5 1-15 0.5 5 Store cold; flow rate/volume from NIOSH 2016. See EPA method for more information on special sampling situations.

Benzene 71-43-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 5-30 1 1

- NIOSH 5042 Gravimetric PTFE-2µm, preweighed 1.0-4.0 28-400 40 - Protect sample from light.

Benzo (a) anthracene also see PAH scans 56-55-3 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Benzo (a) pyrene also see PAH scans 50-32-8 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Benzo (a) pyrene also see PAH scans 50-32-8 OSHA 58 HPLC GFF-37mm 2 960 0.3 6 Protect from light; after sampling: fold filter, wipe inside of cassette with filter, and transfer filter to vial w/ teflon-lined cap.

205-99-2 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Benzo (e) pyrene also see PAH scans 192-97-2 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

191-24-2 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

207-08-9 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43)) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Benzoyl peroxide 94-30-0 NIOSH 5009 HPLC MCE 1.0-3.0 40-400 5 - Store cold; do not exceed particulate loading of 2 mg on the filter.

Benzyl alcohol 100-51-6 OSHA PV 2009 GC/FID XAD-7 (SKC 226-95) 0.2 24 3 -

Benzyl chloride 100-44-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 6-50 3 1

Beryllium (air) 7440-41-7 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 1250-2000 0.02 7 This method cannot be used for beryllium oxide. Do not exceed 2 mg of total dust on filter.

Beryllium (air) 7440-41-7 NIOSH 7303-MS ICP/MS MCE (or PVC-PW w/ total dust) 1.0-4.0 1250-2000 0.005 7 This method cannot be used for beryllium oxide.

Beryllium (air) 7440-41-7 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 60-480 0.02 8 Welding fume method. Use this method when source is beryllium oxide.

Beryllium (air) Wipe samples 7440-41-7 OSHA ID-125G ICP Wipe kit N/A N/A 0.05 -

Beryllium (air) Wipe samples 7440-41-7 EPA 6010 ICP Wipe kit N/A N/A 0.05 -

Biphenyl 92-52-4 NIOSH 2530 GC/FID Tenax (SKC 226-35-01) 0.01-0.5 3-10 1 - Also see phenyl-diphenyl mixture (NIOSH 2013)

Bis-(2-ethylhexyl) phthalate 117-81-7 OSHA 104 GC/FID OVS-Tenax (SKC 226-56) 1 240 5 22

Bisphenol A 80-05-7 NIOSH P&CAM 333 HPLC GFF-37mm 1.6 288 0.4 23

Bisphenol A diglycidyl ether 1675-54-3 NIOSH P&CAM 333 HPLC GFF-37mm 1.6 288 0.5 23

Boron 7440-42-8 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 2 960 1 7 Do not exceed 2 mg of total dust on filter.

Bromine 7726-95-6 NIOSH 6011 IC Silver filter-precleaned 0.3-1 16-360 10 24 Media requires special prep, so filters need to be ordered in advance.

Bromochloromethane 74-97-5 NIOSH 1003 GC/FID CT (SKC 226-01) 0.01-0.2 5-8 5 1

Bromoform 75-25-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-70 10 1

106-99-0 OSHA 56 GC/FID CT-T4 (SKC 226-73 or ORBO351) 0.05 3 1 - Store cold. This is the lab’s preferred method.

106-99-0 NIOSH 1024 GC/FID Anasorb CSC (2 tubes) (SKC 226-37 or -01) 0.01-0.5 3-25 0.5 - Store frozen. Separate tubes after sampling. Lab does not routinely stock 226-37 tubes.

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7901.pdf)

Filters are special order. Once lab treats the filters, samples must be collected w/in 1 week. Do not exceed 2 mg of total dust loading.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6001.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7400.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7402.pdf)

Asphalt fumes See coal tar pitch volatiles and/or benzene solubles

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)- - - - - -

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Note that OSHA 1005 is written for passive monitors (SKC 575-002 or 3M 3520). Lab will cite equivalent analytical method (OSHA 7).

Benzene solubles (also see asphalt fumes and/or coal tar pitch volatiles)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5042.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

Benzo (b) fluoranthene also see PAH scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

Benzo (g,h,i) perylene also see PAH scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

Benzo (k) fluoranthene also see PAH scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5009.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv200

9/2009.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

All wipe methods: Wipe kits are available from the laboratory. LOD may vary with type of media. For Be oxide, must use OSHA ID-125G

[View](http://www3.epa.gov/epawaste/hazard/testmethods/

sw846/pdfs/6010d.pdf)All wipe methods: Wipe kits are available from the laboratory. LOD may vary with type of media. For Be oxide, must use

OSHA ID-125G

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2530.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

04/org104.html)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

18/1018.pdf)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

18/1018.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6011.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1003.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Butadiene, 1,3[View]

(https://www.osha.gov/dts/sltc/methods/organic/org056/org056.html)

Butadiene, 1,3 [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1024.pdf)

Butane, n- 106-97-8 OSHA PV 2010 GC/FID ORBO 91 (2 tubes) 0.05 3 5 12 Media: SKC does not have an equivalent tube available.

111-76-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 2-10 2 17

Butyl acetate, n- 123-86-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1 Ship refrigerated.

Butyl acetate, s- 105-46-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 20 1 Ship refrigerated.

Butyl acetate, t- 540-88-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 20 1 Ship refrigerated.

Butyl acrylate 141-32-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 4 1 Store cold.

Butyl acrylate 141-32-2 OSHA PV 2011 GC/FID CT-T4 (SKC 226-73) 0.05 12 2 -

Butyl alcohol, n- 71-36-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-10 3 1

Butyl alcohol, s- 78-92-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-10 3 1

Butyl alcohol, t- 75-65-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 2 1

Butyl carbitol 112-34-5 OSHA 7 GC/FID CT (SKC 226-01) <0.2 <10 3 17

Butyl carbitol acetate 98100-70-0 OSHA 7 GC/FID CT (SKC 226-01) <0.2 <10 3 17

Butyl cellosolve 111-76-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 2-10 2 17

Butyl glycidyl ether, n- 2426-08-6 NIOSH 1616 GC/FID CT (SKC 226-01) 0.01-0.2 15-30 4 1

Butyl mercaptan, n- 109-79-5 NIOSH 2542 GC/FPD GFF-T6 (SKC 225-9007) 0.1-0.2 10-150 10 13 Protect samples from light.

Butylamine, n- 109-73-9 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 1 9 Store cold.

Cadmium 7440-43-9 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 13-2000 0.5 7 Do not exceed 2 mg of total dust on filter.

Cadmium 7440-43-9 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 0.5 8 Welding fume method.

Calcium 7440-70-2 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-200 10 7 Do not exceed 2 mg of total dust on filter.

Camphor 76-22-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-25 1 -

Caprolactam 105-60-2 OSHA PV 2012 HPLC OVS-7 (SKC 226-57) 1 100 4 -

Captan 133-06-2 NIOSH 5601 HPLC OVS-2 (SKC 226-30-16) 0.1-1.0 30-480 4.8 11 Cold shipment not required, but freezer storage extends stability

Carbaryl 63-25-2 OSHA 63 HPLC OVS-2 (SKC 226-30-16) 1 60 2 - Cold shipment not required, but freezer storage extends stability

Carbaryl 63-25-2 NIOSH 5601 HPLC OVS-2 (SKC 226-30-16) 0.1-1.0 240-480 0.06 11 Cold shipment not required, but freezer storage extends stability

Carbon black 1333-86-4 NIOSH 5000 Gravimetric PVC –PW 1.0-2.0 30-570 50 -

Carbon black 1333-86-4 OSHA ID-196 PVC–PW 2 480-960 100 - First test is gravimetric (as dust). If result >3.5 mg/m3 , client can choose to proceed to 2nd ashing procedure in the method.

Carbon Disulfide 75-15-0 NIOSH 1600 GC/FPD Drier tube (SKC 226-44) / CT (SKC 226-01) 0.01-0.2 2-25 10 - Store cold

Carbon tetrachloride 56-23-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 15-150 4 1 Store cold

Cellosolve 110-80-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 1-6 3 17 Store cold

Cellosolve acetate 111-15-9 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 4 1,17 Store cold

Chlordane 57-74-9 OSHA 67 GC/ECD OVS-2 (SKC 226-30-16) 1 480 0.3 -

Chlordane (alpha, gamma) 57-74-9 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.05 29 Store cold, wrap in tinfoil

Chlorine 7782-50-5 NIOSH 6011 IC Silver filter-precleaned 0.3-1 7-90 10 24 Media requires special prep, filters need to be ordered in advance

Chlorine 7782-50-5 OSHA ID-101 Wet Chem 0.1% Sulfamic acid (FBG) 1 15-240 20 - Ship bottles in glass vials w/Teflon-lined cap

Chlorobenzene 108-90-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-40 3 1

74-97-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 5-8 5 1

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

0/2010.html)

Butoxyethanol, 2[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

1/2011.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1616.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2542.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

2/2012.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5601.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

63/org063.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5601.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5000.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

96/id196.html)Gravimetric / Wet Chem

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1600.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

67/org067.html)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

10ar.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6011.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

01/id101.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Chlorobromomethane [View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

Chloroform 67-66-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 15-50 4 1

Chlorpyrifos (Dursban) 2921-88-2 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 480 0.5 15

Chromic acid 1333-82-0 OSHA ID-215 Wet Chem PVC See notes See notes - - OSHA ID-215 is the preferred method, reported as hexavalent chromium, due to the lower RL and OSHA PEL.

Chromium 7440-47-3 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-1000 1 7 Do not exceed 2 mg of total dust on filter.

Chromium 7440-47-3 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Chromium, hexavalent (Cr+6) Air 18540-29-9 OSHA ID-215 IC PVC 2 960 -

Chromium, hexavalent (Cr+6) Air Wipe 18540-29-9 OSHA ID-215 IC Wipe (quartz or PVC filter; quartz is more durable) - - 0.01 -

Chrysene also see PAH scans 218-01-9 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Chrysene also see PAH scans 218-01-9 OSHA 58 HPLC GFF-37mm 2 960 0.3 6 Protect from light; after sampling: fold filter, wipe inside of cassette with filter, and transfer filter to vial w/ teflon-lined cap.

65996-93-2 OSHA 58 Wet Chem GFF-37mm 2 960 40 6 Protect from light; after sampling: fold filter, wipe inside of cassette with filter, and transfer filter to vial w/ teflon-lined cap.

Cobalt 7440-48-4 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 25-2000 1 7 Do not exceed 2 mg of total dust on filter.

Cobalt 7440-48-4 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Cobalt 7440-48-4 OSHA ID-213 ICP MCE 2 30-480 10 38

Copper 7440-50-8 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-1000 1 7 Do not exceed 2 mg of total dust on filter.

Copper 7440-50-8 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Cresol (o,m,p) 1319-77-3 NIOSH 2546 GC/FID XAD-7 (SKC 226-95) 0.01-0.1 1-24 6 25 Each isomer is reported individually, and a total result is also available.

Cresols, total 1319-77-3 OSHA 32 HPLC XAD-7 (SKC 226-95) 0.1 24 6 26 The result is reported as the total of the sum of the 3 isomers.

Crotonaldehyde also see Aldehyde scans 123-73-9 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.1-1.5 1-15 0.5 5 Store cold

Cumene 98-82-8 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-30 2 1

74-90-8 NIOSH 7904 Wet Chem PVC/ 0.1N KOH (FGB) 0.5-1 1 1-180 3 28 Ship solution in glass vials w/ Teflon-lined caps. Gaseous portion of cyanide is obtained from the impinger.

74-90-8 OSHA ID-120 Wet Chem MCE/ 0.1N NaOH (Imp) 0.5-1 1 90-120 3 27 Ship solution in glass vials w/ Teflon-lined caps. Gaseous portion of cyanide is obtained from the impinger.

Cyanide (particulate) 57-12-5 NIOSH 7904 Wet Chem PVC/ 0.1N KOH (FGB) 0.5-1 1-180 3 28

Cyanide (particulate) 57-12-5 OSHA ID-120 Wet Chem MCE/ 0.1N NAOH (Imp) 1 90-120 3 27

Cyclohexane 110-82-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2.5-5 2 1

Cyclohexanol 108-93-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 4 1

Cyclohexanone 108-94-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 4 1

Cyclohexene 110-83-8 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 5-7 2 1

Cyclohexylamine 108-91-8 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) 0.01-0.2 3-96 1 9 Store cold. This is the lab’s preferred method.

Cyclohexylamine 108-91-8 OSHA PV 2016 GC/FID XAD-7 treated (H2SO4) (SKC 226-98) 0.1-0.2 10-20 2 40 Store samples cold if not shipped to lab quickly.

72-55-9 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.05 29

50-29-3 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.05 29

Di-n-octyl phthalate 117-84-0 OSHA 104 GC/FID OVS-Tenax (SKC 226-56) 1 240 10 22

Diacetone alcohol 123-42-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 10 1 Store cold.

Diacetyl 431-03-8 OSHA 1013 GC/FID SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 9 (3 for STEL) 1 42 Protect samples from light during and after sampling, using tube holders, aluminum foil, or other means. Store cold.

Diacetyl 431-03-8 OSHA 1012 GC/ECD SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 9 (3 for STEL) 0.05 41 Protect samples from light during and after sampling, using tube holders, aluminum foil, or other means. Store cold.

Diazinon 333-41-5 NIOSH 5600 GC/FPD OVS-2 (SKC 226-30-16) 0.2-1.0 12-240 0.5 15

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

15/id215.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

15/id215.html)

0.01 (0.035 for

paint prep)

Use this method for OSHA PEL. If sample collected from a paint operation (spray or grinding), client must notify the lab on COC--special sample prep required! Welding must be analyzed w/in 8 days of collection; plating w/in 6 days.

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

15/id215.html)

Wipe with dry filter (unless sampling a plating operation, then see method). After wiping, place wipe in vial and ship to lab. OSHA Protocol W4001 has details.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

Coal Tar Pitch Volatiles (CTPV) also see benzene solubles and/or asphalt fumes

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

13/id213.html)

PVC can only be used for soluble cobalt. Special instructions for soluble – see Section 2.2.6 of method for details. This method only compatible with tungsten.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2546.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

32/org032.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Cyanide (gaseous) also see hydrogen cyanide

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7904.pdf)

Cyanide (gaseous) also see hydrogen cyanide

[View](https://www.osha.gov/dts/sltc/methods/validated/id1

20/id120.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7904.pdf)

Ship solution in glass vials w/ Teflon-lined caps. Particulate portion of cyanide is obtained from the filter, which must be analyzed within 5 days of sample collection.

[View](https://www.osha.gov/dts/sltc/methods/validated/id1

20/id120.html) Ship solution in glass vials w/ Teflon-lined caps. Particulate portion of cyanide is obtained from the filter, which must be

analyzed within 5 days of sample collection.

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

6/2016.html)

DDE, 4,4'also see Pesticide scans[View]

(http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-10ar.pdf)

Store cold; wrap in foil for shipment; lab must extract sample within 7 days of sampling. Lab does not stock PUF media. See method for more details.

DDT, 4,4'also see Pesticide scans[View]

(http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-10ar.pdf)

Store cold; wrap in foil for shipment; lab must extract sample within 7 days of sampling. Lab does not stock PUF media. See method for more details.

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

04/org104.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

13/1013.pdf)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

12/1012.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5600.pdf)

Diazinon 333-41-5 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 480 0.5 15

- OSHA PV 2019/2020/2021 GC/FID CT (SKC 226-01) 0.2 20 10 36 Store cold. Analysis should be performed within 1 wk. of collection, so schedule with laboratory.

53-70-3 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

96-12-8 In-house method GC/ECD Anasorb 747 (SKC 226-81A) ≤0.2 ≤10 0.005 -

Dibutyl phthalate 84-74-2 OSHA 104 GC/FID OVS-Tenax (SKC 226-56) 1 240 10 22

75-34-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-15 3 1

107-06-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-15 3 1

75-35-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-7 3 1

78-87-5 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 ≤10 3 1

Dichlorvos (DDVP) 62-73-7 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 480 0.5 15

Diesel fuel 68334-30-5 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 20 1 If available, submit bulk reference material in separate packaging.

Diesel particulate 7440-44-0 NIOSH 5040 Quartz (precleaned) or SKC DPM cassette 1.0-4.0 106-4300 4 (total) -

Diethanolamine 111-42-2 OSHA PV 2018 HPLC XAD2-T5 (SKC 226-30-18) 0.1 10 10 37 Method similar to OSHA 60 or NIOSH 2540.

Diethyl ether 60-29-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 0.25-3 2 1

Diethyl phthalate 84-66-2 OSHA 104 GC/FID OVS-Tenax (SKC 226-56) 1 240 10 22

Diethylamine 109-89-7 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 2 10

Diethylene glycol 111-46-6 NIOSH 5523 GC/FID OVS-7 (SKC 226-57) 0.5-2.0 5-60 20 16 Store cold.

Diethylenetriamine 111-40-0 NIOSH 2540 HPLC XAD2-T5 (SKC 226-30-18) 0.01-0.1 1-20 10 -

Diethylenetriamine 111-40-0 OSHA 60 HPLC XAD2-T5 (SKC 226-30-18) 0.1 10 10 -

Diethylethanolamine 100-37-8 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-0.2 4-24 1 - Keep samples frozen. See method if long-term (more than 2 wks) storage required.

Diisobutyl ketone 108-83-8 NIOSH 1300 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Diisopropylamine 108-18-9 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 5 9 Store cold.

Dimethyl acetamide 127-19-5 NIOSH 2004 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 15-80 1 -

Dimethyl adipate also see dibasic esters 627-93-0 OSHA PV 2019 GC/FID CT (SKC 226-01) 0.2 20 3 36 Store cold. Recommend analyzing within 2 wks.

Dimethyl-cyclohexylamine 98-94-2 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 1 9

Dimethyl disulfide 624-92-0 In-house method GC/FPD CT (SKC 226-01) ≤0.1 ≤10 1 30

Dimethyl ethanolamine 108-01-0 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-0.2 4-24 1 - Keep samples frozen. See method if long-term storage (more than 2 wks) required.

Dimethyl ethylamine 598-56-1 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 1 -

Dimethyl formamide 68-12-2 NIOSH 2004 GC/FID SG (SKC 226-10 or 226-15) 0.01-1.0 15-80 5 -

Dimethyl formamide 68-12-2 OSHA 66 GC/NPD CT (SKC 226-01) 0.2 10 1 -

Dimethyl glutarate also see dibasic esters 1119-40-0 OSHA PV 2020 GC/FID CT (SKC 226-01) 0.2 20 3 36 Store cold. Analyze within 2 wks.

Dimethyl phthalate 131-11-3 OSHA 104 GC/FID OVS-Tenax (SKC 226-56) 1 240 10 22

106-65-0 OSHA PV 2021 GC/FID CT (SKC 226-01) 0.2 20 3 36 Store cold. Analysis should be performed within 1 wk. of collection, so schedule with laboratory.

Dimethyl sulfate 77-78-1 NIOSH 2524 GC/FPD Porapak P (SKC 226-114) 0.01-0.2 0.25-12 0.5 -

Dimethyl sulfide 75-18-3 In-house method GC/FPD CT (SKC 226-01) ≤0.1 ≤5.0 1 30

99-97-8 NIOSH 2002 GC/FID SG (SKC 226-10 or 226-15) 0.02-1.0 5-30 10 18

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

Dibasic esters mix of dimethyl adipate, dimethyl glutarate, and dimethyl succinate

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

9/2019.html)

Dibenzo (a,h)anthracene also see PAH scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

1,2-Dibromo3-chloropropane

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

04/org104.html)

Dichloroethane, 1,1[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

Dichloroethane, 1,2[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

Dichloroethylene, 1,1[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

Dichloropropane, 1,2(also called propylene dichloride)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5040.pdf) Thermo-optical See method for various sampling scenarios; at least one field blank is required. SKC DPM often needed for monitoring in

mines.

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

8/2018.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

04/org104.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5523.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2540-2.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

60/org060.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1300.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2004.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv201

9/2019.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2004.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

66/org066.html)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv202

0/2020.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

04/org104.html)

Dimethyl succinate also see dibasic esters [View]

(https://www.osha.gov/dts/sltc/methods/partial/pv2021/2021.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2524.pdf)

Dimethyl-ptoluidine, n,n- [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2002.pdf)

Dimethylamine 124-40-3 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 3 10 Store cold.

Dimethylaniline 121-69-7 NIOSH 2002 GC/FID SG (SKC 226-10 or 226-15) 0.02-1.0 3-30 5 18

123-91-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 0.5-15 3 1

Dowanol DPM 34590-94-8 OSHA 7 GC/FID CT (SKC 226-01) ≤0.1 ≤10 2 17

Dowanol PM 107-98-2 OSHA 7 GC/FID CT (SKC 226-01) ≤0.1 ≤10 2 17

Dowanol PMA 108-65-6 OSHA 7 GC/FID CT (SKC 226-01) ≤0.1 ≤10 2 1, 17

Dust (see particulate) - NIOSH 0500/0600 Gravimetric - - - - - Sampling depends on whether dust is respirable or total.

Elemental carbon (diesel particulate) - NIOSH 5040 Therm-optical Quartz (precleaned) or SKC DPM 1.0-4.0 106-4300 4 (total) - See method for various sampling scenarios; at least one field blank is required. Note the RL for elemental carbon is 2 µg.

Endrin 72-20-8 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.1 29

Epichlorohydrin 106-89-8 NIOSH 1010 GC/FID CT (SKC 226-01) 0.01-0.2 2-30 5 1

141-43-5 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-0.2 4-24 1 - Keep samples frozen. See method if long-term storage (more than 2 wks) required.

Ethyl acetate 141-78-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Ethyl acrylate 140-88-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 5 1

Ethyl acrylate 140-88-5 OSHA 92 GC/FID CT-T4 (SKC 226-73 or ORBO 351) 0.05 12 2 - Cold shipment not required, but suggested

Ethyl alcohol 64-17-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 0.1-1 5 1 Store cold

Ethyl bromide 74-96-4 NIOSH 1011 GC/FID CT (SKC 226-01) 0.01-0.2 0.5-4 10 -

Ethyl carbitol 111-90-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 1-10 3 17

Ethyl cellosolve 96231-36-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 1-10 3 17 Store cold.

Ethyl cellosolve acetate 111-15-9 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1,17

7085-85-0 OSHA 55 HPLC XAD7-T7 (SKC 226-98) 0.1 12 3 - Store cold.

Ethyl ether 60-29-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 0.25-3 2 1

763-69-9 OSHA 7 GC/FID CT (SKC 226-01) ≤0.1 ≤10 2 1

Ethyl mercaptan 75-08-1 NIOSH 2542 GC/FPD GFF-T6 (SKC 225-9007) 0.1-0.2 10-150 4 13 Protect from light.

Ethyl parathion 56-38-2 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 480 0.5 15

Ethyl silicate 78-10-4 NIOSH S-264 [View](http://www.cdc.gov/niosh/pdfs/s264.pdf) GC/FID XAD-2 (SKC 226-30-04) 0.05 ≤9 3 -

Ethylamine 75-04-7 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 2 10 Store cold.

Ethylbenzene 100-41-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-24 2 1

Ethylene dibromide 106-93-4 OSHA 7 GC/FID CT (SKC 226-01) 0.02-0.2 0.1-25 5 - Store cold.

Ethylene glycol 107-21-1 NIOSH 5523 GC/FID OVS-7 (SKC 226-57) 0.5-2.0 5-60 20 16 Store cold.

Ethylene oxide 75-21-8 OSHA 1010 GC/ECD CT-T8 (SKC 226-178) 0.05 0.75-12 0.6 - Store cold.

Ethylene oxide 75-21-8 OSHA 49 GC/ECD 3M 3551 badge NA 480 min. 2 -

Ethylenediamine 107-15-3 NIOSH 2540 HPLC XAD2-T5 (SKC 226-30-18) 0.01-0.1 1-20 10 37

Ethylenediamine 107-15-3 OSHA 60 HPLC XAD2-T5 (SKC 226-30-18) 0.1 10 10 37

103-11-7 OSHA PV2026 GC/FID CT-T4 (SKC 226-73 or ORBO 351) 0.1 12 2 - Store cold.

Fibrous glass also see other fiber options NIOSH 7400B PCM MCE-25mm 0.5-16 400-5000 5 f/mm2 21 Sample open-faced.

Fluoranthene also see PAH scans 206-44-0 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2002.pdf)

Dioxane, 1,4[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5040.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

10ar.pdf)Store cold; wrap in foil for shipment; lab must extract sample within 7 days of sampling. Lab does not stock PUF media. See

method for more details.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1010.pdf)

Ethanolamine (also called monoethanolamine)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

92/org092.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Ethyl cyanoacrylate, 2

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Ethyl-3-ethoxypropionate [View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2542.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)OSHA 1002 is written for passive badges (SKC 575002). Lab will cite equivalent analytical method (OSHA 7).

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5523.pdf)

[View](https://www.osha.gov/dts/sltc/methods/mdt/mdt101

0/1010.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

49/org049.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2540-2.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

60/org060.html)

Ethylhexyl acrylate, 2[View]

(https://www.osha.gov/dts/sltc/methods/partial/pv2026/2026.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7400.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

Fluorene also see PAH scans 86-73-7 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Fluoride (gaseous) 7664-39-3 NIOSH 7902 Wet Chem MCE / Cellulose pad-T9 1.0-2.0 25-800 50 31 Can be collected with particulate fluoride (below)

Fluoride (gaseous) 7664-39-3 OSHA ID-110 Wet Chem MCE / Cellulose pad-T9 1.5 22.5-90.0 130 32 Can be collected with particulate fluoride (below)

Fluoride (particulate) 16984-48-8 NIOSH 7902 Wet Chem MCEF (treated cellulose pad optional) 1.0-2.0 25-800 50 31 Can be collected with gaseous fluoride (above)

Fluoride (particulate) 16984-48-8 OSHA ID-110 Wet Chem MCEF (treated cellulose pad optional) 1.5 22.5-90.0 130 32 Can be collected with gaseous fluoride (above)

Formaldehyde also see Aldehyde scans 50-00-0 NIOSH 2016 HPLC SG-T2 (SKC 226-119) 0.03-1.5 1-15 0.1 5 Store cold. Ozone is a possible interference (see method).

Formaldehyde also see Aldehyde scans 50-00-0 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.03-1.5 1-15 0.1 5 Store cold; flow rate/ volume are from NIOSH 2016. See EPA method for more information on special sampling situations.

Formaldehyde also see Aldehyde scans 50-00-0 OSHA 52 GC/NPD 0.1 0.2 24 3 1 0.5 19

Formaldehyde also see Aldehyde scans 50-00-0 NIOSH 3500 Wet Chem NaHSO3 (Imp) 0.2-1.0 1-100 20 - Ship samples in polyethylene bottles; add PTFE (1µm) filter to train in dusty environments.

Formaldehyde also see Aldehyde scans 50-00-0 OSHA ID-205 Wet Chem 3M 3721 badge NA 480 min. 1 - Field blank is normally required for blank correction. Follow badge maker’s instructions.

Formaldehyde also see Aldehyde scans 50-00-0 OSHA 1007 HPLC SKC UMEx 100 or AT 571 badges NA 15-240 min. -

Formaldehyde also see Aldehyde scans 50-00-0 NIOSH 3500 Wet Chem SKC 526 series badges NA Follow badge maker’s instructions. Badges to be obtained directly from SKC; lab does not normally stock the badges.

Formic Acid 64-18-6 NIOSH 2011 IC SG-T12 (SKC 226-10-03 or ORBO 53) 0.05-0.2 1-24 6 35

Freon 113 76-13-1 NIOSH 1006 GC/FID CT (SKC 226-01) (2 tubes) 0.01-0.05 0.3-7 4 1 Store cold; separate tubes after sampling.

Freon 114 76-14-2 NIOSH 1018 GC/FID CT (SKC 226-01) (2 tubes) 0.01-0.05 1-4 5 - Store cold; separate tubes after sampling.

Freon 141B 1717-00-6 OSHA 7 GC/FID CT SKC 226-01 (2 tubes) ≤0.05 ≤1.0 7 1 Store cold; separate tubes after sampling.

Freon 22 75-46-6 OSHA 7 GC/FID CT SKC 226-01 (2 tubes) 0.01-0.05 1-4 10 - Store cold; separate tubes after sampling.

Furfural 98-01-1 OSHA 72 GC/FID Anasorb 747 (SKC 226-81A) 1 180 4 -

Furfuryl alcohol 98-00-0 NIOSH 2505 GC/FID Porapak Q (SKC 226-115) 0.01-0.05 3-25 3 -

gamma-BHC 58-89-9 EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 0.1 29 Store cold; Protect from light

Glutaraldehyde 111-30-8 NIOSH 2532 HPLC SG-T2 (SKC 226-119) 0.05-0.5 1-30 0.5 5

Glutaraldehyde 111-30-8 OSHA 64 HPLC GFF-T10 (SKC 225-9003) 1 15 0.2 - Store cold; Protect from light; Two filters are in one cassette

Halothane 151-67-7 OSHA 103 GC/FID Anasorb CMS or 747 (SKC 226-121 or -81A) 0.05 12 10 35 Store cold.

Heptane 142-82-5 OSHA 7 GC/FID CT (SKC 226-01) 0.1-0.2 4 2 1

87-68-3 NIOSH 2543 GC/ECD XAD-2 (SKC 226-30-04) 0.05-0.2 1-100 0.005 - Store cold; protect from light.

Hexachloroethane 67-72-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-70 3 1

Hexaldehyde also see Aldehyde scans 9012-63-9 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.1-1.5 1-15 0.5 5 Store cold; flow rate/ volume from NIOSH 2016.

822-06-0 NIOSH 5521 HPLC Pip/Tol soln (Imp) 1 5-500 0.2 33 Ship samples in glass vials w/ teflon-lined caps.

822-06-0 OSHA 42 HPLC GFF-T11 (SKC 225-9002) 1 15-240 0.2 4 Store cold; sample open-faced; protect from light.

124-09-4 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1 3-30 2 - Store cold.

Hexane, n- 110-54-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 4 2 1

Hexyl cellosolve 32167-24-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 1-10 2 17

Hexylene glycol 107-41-5 In-house method GC/FID CT (SKC 226-01) 0.2 3 3 17

Hydrazine 301-01-2 OSHA 108 HPLC GFF-T3 (SKC 225-9004) 1 240 (15 for STEL) 0.1 - Store cold. Can also use SKC 225-9012

Hydrazoic acid 7782-79-8 OSHA ID-211 IC SG -T19 (SKC 226-55) 1 ≤5.0 0.2 - Store cold.

Hydrobromic acid also see acid scan 10035-10-6 NIOSH 7903 IC SG-T12 (SKC 226-10-03 OR ORBO 53) 0.2-0.5 3-100 5 3

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7902.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

10/id110.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7902.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

10/id110.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2016.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

52/org052.html)

XAD-2 (T1); for TWA use SKC 226-117 or ORBO 24. For STEL use SKC 226-54

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/3500.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

05/id205.html)

[View](https://www.osha.gov/dts/sltc/methods/mdt/mdt100

7/1007.pdf)

0.1 (0.05 for STEL)

Store cold before and after sampling. Do not use badges if 1) source is formalin, or 2) rel. humidity <10%. Ozone is possible interference (see method). Follow badge maker’s instructions. Specify on CoC if sample is a STEL.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/3500.pdf)

STEL, PEL, and IAQ options

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2011.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1006.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1018.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

72/org072.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2505.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

10ar.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2532.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

64/org064.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

03/org103.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Hexachlorobutadiene [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2534.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

Hexamethylene diisocyanate (HDI) see isocyanate scan also

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5521.pdf)

Hexamethylene diisocyanate (HDI) see isocyanate scan also

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

42/org042.html)

Hexamethylenediamine [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org1

08/org108.html)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

11/id211.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

Hydrocarbons, total NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1

Hydrochloric acid also see acid scan 7647-01-0 NIOSH 7903 IC SG-T12 (SKC 226-10-03 OR ORBO 53) 0.2-0.5 3-100 3 3

Hydrofluoric acid also see acid scan 7664-39-3 NIOSH 7903 IC SG-T12 (SKC 226-10-03 OR ORBO 53) 0.2-0.5 3-100 2 3

Hydrogen cyanide also see cyanide 74-90-8 NIOSH 6010 Wet Chem Soda lime (SKC 226-28) 0.05-0.2 2-90 1 - See SKC’s instructions for tubes before sampling.

Hydrogen peroxide 7722-84-1 OSHA ID-006 Wet Chem TiOSO4 (FGB) 0.5 100 40 - Ship samples in plastic or glass bottles.

Hydrogen sulfide 7783-06-4 NIOSH 6013 IC PTFE (0.45) / ORBO 34 0.1-1.5 5-40 20 -

Hydrogen sulfide 7783-06-4 OSHA ID-1008 IC SG-treated (AgNO3) & treated GFF (SKC 226-177) 0.05-0.5 5-12 10 39 Store cold. Use media from the same lot for each sample batch.

Hydrogenated MDI (H2MDI) 88504-76-1 OSHA PV2092 HPLC GFF-T11 (SKC 225-9002) 1 15 0.4 4 Store cold; sample open-faced; protect from light. Similar to OSHA 42.

Hydroquinone 123-31-9 NIOSH 5004 HPLC MCE 1.0-3.0 30-180 10 - Transfer filter to a glass bottle containing 10 mL of 1% acetic acid.

Hydroquinone 123-31-9 OSHA PV 2094 HPLC XAD7-T7 (SKC 226-98) 0.2 20 0.5 -

193-39-5 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Inorganic Acid Scan also see scans NIOSH 7903 IC SG-T12 (SKC 226-10-03 OR ORBO 53) 0.2-0.5 3-100 Varies 3

Iodine 7553-56-2 OSHA ID-212 Wet Chem Carbon bead-T (SKC 226-80) 0.5 ≤5.0 5 -

Iron 7439-89-6 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1-4 5-100 1 7 Do not exceed 2 mg of total dust on filter.

Iron 7439-89-6 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Isoamyl alcohol 123-51-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 4 1

Isobutyl acetate 110-19-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Isobutyl alcohol 78-83-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-10 4 1

Isophorone 78-59-1 OSHA 7 GC/FID Anasorb 747 (SKC 226-81A) 0.01-1.0 2-25 3 - Store cold.

Isophorone diisocyanate (IPDI) 4098-71-9 OSHA 42 HPLC GFF-T11 (SKC 225-9002) 1 15 0.4 4 Store cold; sample open-faced; protect from light.

Isopropyl acetate 108-21-4 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 ≤9.0 2 1

Isopropyl alcohol 67-63-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-10 4 1 Store cold.

Isopropyl ether 108-20-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 0.1-3.0 2 1

Isopropylamine 75-31-0 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.2 3-96 1 9 Store cold.

Kerosene 8008-20-6 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 40 1 If available, submit bulk reference material in separate packaging.

Lanthanum 7439-91-0 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-1000 1 7 Not in the standard, 28-metal scan.

Lead Air samples 7439-92-1 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 50-2000 1 7 Do not exceed 2 mg of total dust on filter.

Lead Air samples 7439-92-1 NIOSH 7303-MS ICP/MS MCE (or PVC-PW w/ total dust) 1.0-4.0 50-2000 0.05 7

Lead Air samples 7439-92-1 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Lead Wipe samples 7439-92-1 EPA 6010 ICP ICP/MS Wipe kit N/A N/A 10 - All wipe methods: Wipe kits are available from the laboratory.

Lead Paint chips 7439-92-1 EPA 6010 ICP Place sample in vial or ziplock baggie - - Varies - LOD varies with amount of sample.

Limonene, d- 5989-27-5 OSHA 7 GC/FID CT (SKC 226-01) 0.2 10 3 1 Store cold.

Lithium 7439-93-2 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 100-2000 1 7 Do not exceed 2 mg of total dust on filter.

Magnesium 7439-95-4 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-67 10 7 Do not exceed 2 mg of total dust on filter.

Malathion 121-75-5 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 60 0.5 15

Maleic anhydride 108-31-6 OSHA 25 HPLC XAD-2 (T14) / XAD-2 (SKC 226-30-07 and -30) 0.1 20 0.5 - Store cold; protect from light.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6010.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id0

06/hydrogen_peroxide.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6013.pdf)

A field blank is required. Analysis of the filter for sulfate is optional and will incur an additional cost (see sulfur oxides by NIOSH 6004). See method for more details.

[View](https://www.osha.gov/dts/sltc/methods/validated/10

08/1008.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/t-pv2092-01-8804-ch/t-pv2092-01-8804-ch.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5004.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv209

4/pv2094.html)

Indeno (1,2,3-cd) pyrene also see PAH scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

12/id212.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)OSHA 1009 is written for passive badges (SKC 575002 and SKC 3520). Lab will cite equivalent analytical method (OSHA 7).

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

42/org042.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www3.epa.gov/epawaste/hazard/testmethods/

sw846/pdfs/6010d.pdf)

[View](http://www3.epa.gov/epawaste/hazard/testmethods/

sw846/pdfs/6010d.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

25/org025.html)

Maleic anhydride 108-31-6 OSHA 86 HPLC GFF (treated with veratrylamine) (SKC 225-9021) 0.5 60 2 - Isocyanates, acid chlorides, and anhydrides (other than maleic) may reduce media capacity.

Manganese 7439-96-5 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-200 1 7 Do not exceed 2 mg of total dust on filter.

Manganese 7439-96-5 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Mercury (vapor) 7439-97-6 NIOSH 6009 AA Cold Vapor Hopcalite (SKC 226-17-1A) 0.15-0.25 2-100 0.05 - SKC passive method also available;

Mercury (vapor) 7439-97-6 OSHA ID-140 AA Cold Vapor Hopcalite (SKC 226-17-1A) 0.2 3-100 0.1 - SKC passive method also available;

Mercury (particulate) 7439-97-6 OSHA ID-145F AA Cold Vapor MCE 2 ≤10 0.1 -

NIOSH 5524 Gravimetric PTFE-2 µm, preweighed and precleaned 2 960 100 - Store cold. Lab must analyze w/in 2 wks. of sample collection. Also called oil mist.

Metals-Welding Scan 13 metals OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 1.0-3.0 250-1000 Varies 8 Welding fume method.

Metals Scans 28 metals NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-3.0 250-1000 Varies 7 Do not exceed 2 mg of total dust on filter.

Metals Scans Wipe Samples EPA 6010 ICP Wipe kit N/A N/A Varies - EPA 6010 is equivalent to NIOSH 7300.

Methacrylic acid 79-41-4 OSHA PV 2005 HPLC Anasorb 708 (2 tubes) (SKC 226-30-08) 0.1 24 2 - Store cold; protect samples from light; separate tubes after sampling

Methanol 67-56-1 NIOSH 2000 GC/FID SG (SKC 226-10 or 226-15) 0.02-0.2 1-5 4 - Store cold. If concerned about breakthrough, sample w/ 2 tubes in series and separate after sampling.

Methanol 67-56-1 OSHA 91 GC/FID Anasorb 747 (2 tubes) (SKC 226-83) 0.05 3-5 20 - Store cold. Separate tubes after sampling. Volumes: 3L if rel. humidity (RH) <50%; 5L if RH >50% (at 25 °C)

Methyl acrylate 96-33-3 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 ≤5.0 10 1

Methyl acrylate 96-33-3 OSHA 92 GC/FID CT-T4 (SKC 226-73 or ORBO 351) 0.05 12 2 - Cold shipment not required, but storage at reduced temperature suggested.

Methyl amyl ketone 110-43-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-5 3 -

Methyl aniline 100-61-8 NIOSH 2002 GC/FID SG (SKC 226-10 or 226-15) 0.02-0.2 5-30 5 18

Methyl bromide 74-83-9 OSHA PV 2040 GC/FID Anasorb 747 (2 tubes) (SKC 226-83) 0.05-0.2 ≤3 2 - Store cold. Separate tubes after sampling. Analyze w/in 2 wks. of sample collection.

Methyl butyl ketone 591-78-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Methyl cellosolve 109-86-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 42014 3 17

Methyl cellosolve acetate 110-49-6 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 ≤20 3 17

Methyl chloride 74-87-3 NIOSH 1001 GC/FID CT SKC 226-01 (2 tubes) 0.01-0.1 0.4-3 2 1 Store cold; separate tubes after sampling.

Methyl ethyl ketone (MEK) 78-93-3 NIOSH 2555 GC/FID Anasorb 747 (SKC 226-81A or ORBO 90) 0.01-0.2 1.0-12 3 -

Methyl ethyl ketone (MEK) 78-93-3 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 ≤12 2 1

Methyl formate 107-31-3 OSHA PV 2041 GC/FID Anasorb 747 (SKC 226-83) 0.05 3 5 -

Methyl iodide 74-88-4 NIOSH 1014 GC/FID CT (SKC 226-01) 0.01-1.0 15-50 10 -

Methyl isoamyl ketone 110-12-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Methyl isobutyl carbinol 108-11-2 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-25 4 -

Methyl isobutyl ketone (MIBK) 108-10-1 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Methyl mercaptan 74-93-1 NIOSH 2542 GC/FPD GFF-T6 (SKC 225-9007) 0.1-0.2 10-150 4 13 Protect from light.

Methyl methacrylate 80-62-6 NIOSH 2537 GC/FID XAD-2 (SKC 226-30-06) 0.01-0.05 1-8 5 -

Methyl methacrylate 80-62-6 OSHA 94 GC/FID CT-T4 (SKC 226-73) 0.05 3 2 - Store samples cold.

Methyl parathion 298-00-0 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 480 1 15

Methyl propyl ketone 107-87-9 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 3 1

Methyl styrene 98-83-9 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 3-30 20 1

Methyl tert-butyl ether (MTBE) 1634-04-4 OSHA 7 GC/FID CT (SKC 226-01) (2 tubes) 0.1-0.2 2-96 2 1 Separate tubes after sampling.

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

86/org086.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6009.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

40/id140.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

45/id145.html)

Metal-working fluids (MWF) method includes particulate analysis

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5524.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www3.epa.gov/epawaste/hazard/testmethods/

sw846/pdfs/6010d.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv200

5/2005.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2000.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

91/org091.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

92/org092.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2002.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv204

0/2040.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1001.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2555.pdf) OSHA 1004 is written for passive badges (SKC 575002 or 3M 3520). Lab will cite equivalent analytical method (OSHA 7).

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv204

1/2041.html)

Must store samples cold, schedule analysis in advance with lab, and ship quickly to lab (method shows approx. 18% loss after 7 days of cold storage).

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1014.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)OSHA 1004 is written for passive badges (SKC 575002 or 3M 3520). Lab will cite equivalent analytical method (OSHA 7).

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2542.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2537.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

94/org094.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

n-Methyl-2 pyrrolidone (nmp) 872-50-4 OSHA 7 GC/FID CT (SKC 226-01) 0.2 10 3 17 This is the default method if none specified on COC. Store cold; protect from light.

n-Methyl-2 pyrrolidone (nmp) 872-50-4 NIOSH 1302 GC/NPD CT (SKC 226-01) 0.05-0.2 0.5-125 3 -

Methylamine 74-89-5 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 3 10 Store cold.

Methylcyclohexane 108-87-2 NIOSH 2007 GC/FID CT (SKC 226-01) 0.2 4 2 1 Store cold

101-68-8 NIOSH 5521 HPLC Pip/Tol soln. (Imp) 1 5-500 0.2 33 Store cold

101-68-8 OSHA 47 HPLC GFF-T11 (SKC 225-9002) 1 15-240 0.2 4 Recommend: transfer filter to vial w/ DMSO/ACN after sampling.

Methylene chloride 75-09-2 OSHA 80 GC/FID Anasorb CMS (ORBO 90, 91 or SKC 226-81A) 0.05 3 3 -

Methylene chloride 75-09-2 NIOSH 1005 GC/FID CT (SKC 226-01) (2 tubes) 0.01-0.2 0.5-2.5 3 1 Separate tubes after sampling.

Methylenedianiline, 4,4’-(MDA) 101-77-9 OSHA 7 HPLC GFF-T3 (SKC 225-9004) 1.0-2.0 10-1000 0.2 - Before shipping, transfer filter to glass vial containing 4 mL 0.1N KOH. Before shipping, transfer filter to glass vial containing

Methylenedianiline, 4,4’-(MDA) 101-77-9 OSHA 57 GC/ECD GFF-T3 (SKC 225-9004) 1 100 0.03 -

Mineral spirits 68551-17-7 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1

Molybdenum 7439-98-7 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-67 1 7

Molybdenum 7439-98-7 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8

Morpholine 110-91-8 NIOSH 2010 GC/NPD SG (SKC 226-10 or 226-15) ≤0.2 20 1 - Based on 2nd -Ed. NIOSH S150 method.

Morpholine 110-91-8 OSHA PV 2123 GC/FID XAD-7 treated (H2SO4) (SKC 226-98) 0.1 10 40 40 Store samples cold if not shipped to lab quickly.

Naphtha 8030-30-6 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1 If available, submit bulk reference material in separate packaging.

Naphthalene also see PAH scans 91-20-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-1.0 100-200 10 1

Naphthalene also see PAH scans 91-20-3 OSHA 35 GC/FID Chrm 106 (SKC 226-110) 0.2 10 1 -

Naphthalene also see PAH scans 91-20-3 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

134-32-7 OSHA 93 GC/ECD GFF-T3 (SKC 225-9004) 1 100 0.05 - Transfer filter into a glass vial w/ 2 mL DI water, w/in 10 hrs. of sampling.

Nickel 7440-02-0 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-1000 1 7 Do not exceed 2 mg of total dust on filter.

Nickel 7440-02-0 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Nickel carbonyl 13463-39-3 NIOSH 6007 ICP/MS ORBO 304 (see Special Instructions) 0.05 – 0.2 7-80 0.01 - Also use a 0.8 MCE prefilter, if particulate nickel could be present.

Nicotine 54-11-5 NIOSH 2544 GC/NPD XAD-2 (SKC 226-30-04) ≤1.0 100 2 -

Nicotine 54-11-5 NIOSH 2551 GC/NPD XAD-4 (SKC 226-93) 0.1-1.0 0.5-600 2 - Store cold. Protect from prolonged exposure to light.

Nitric acid also see acid scan 7697-37-2 NIOSH 7903 IC SG-T12 (SKC 226-10-03 or ORBO 53) 0.2-0.5 3-100 10 3

Nitric oxide 10102-43-9 OSHA ID-190 IC Mol. Sieve Set-T15 (SKC 226-40) 0.025 6 4 - Store cold; see method for sampling train.

Nitrobenzene 98-95-3 NIOSH 2005 GC/FID SG (SKC 226-10 or 226-15) 0.01-1.0 10-150 3 -

Nitrogen dioxide (NO2) 10102-44-0 OSHA ID-182 IC Mol. Sieve-T15 (SKC 226-40-02) 0.2 3 3 - Store cold.

Nitrogen oxides (NO/NO2) NIOSH 6014 Wet Chem Mol. Sieve Set-T15 (SKC 226-40) 0.025 1.5-6.0 3/2 - Store cold; see method for sampling train (3 tubes in series)

Nitroglycerin 55-63-0 NIOSH 2507 GC/ECD Tenax (SKC 226-35-03) 0.2-1.0 3-100 0.5 -

Nitromethane 75-52-5 NIOSH 2527 GC/FID Chrm. 106 (SKC 226-111A) 0.01-0.05 1.0-3.0 20 -

Nuisance dust (respirable) NIOSH 0600 Gravimetric PVC-PW (cyclone type determines 2-pc. or 3-pc. cassette) 20-400 50 - Requires use of a cyclone; follow manufacturer’s instructions for flow rate.

Nuisance dust (total) NIOSH 0500 Gravimetric PVC-PW-2pc 1.0-2.0 7-133 50 -

Octane 111-65-9 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 4 2 1 Store cold.

Oil mist (as particulate) 8012-95-1 NIOSH 0500 Gravimetric PVC-PW 1.5-2.0 25-133 50 -

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1302.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

Methylene bisphenyl isocyanate (MDI) also see isocyanate scan

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5521.pdf)

Methylene bisphenyl isocyanate (MDI) also see isocyanate scan

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

47/org047.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

80/org080.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1005.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

57/org057.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

2 mL DI water. If available, submit bulk reference material in separate packaging. Do not exceed 2 mg of total dust on filter. Welding fume method.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

2 mL DI water. If available, submit bulk reference material in separate packaging. Do not exceed 2 mg of total dust on filter. Welding fume method.

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

2 mL DI water. If available, submit bulk reference material in separate packaging. Do not exceed 2 mg of total dust on filter. Welding fume method.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2010.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv212

3/pv2123.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

35/org035.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

Naphthylamine, 2or 1[View]

(https://www.osha.gov/dts/sltc/methods/organic/org093/org093.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2544.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2551.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

90/id190.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2005.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

82/id182.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6014-1.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2507nit.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2527.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0600.pdf)

See special handling instructions.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

8012-95-1 NIOSH 5524 Gravimetric PTFE-2 µm, preweighed and precleaned 2 960 100 - Store cold. Lab must analyze w/in 2 wks. of collection.

Oil mist (mineral) 8012-95-1 NIOSH 5524 IR PVC-PW 1.0-2.0 20-500 50 -

Organotins also see organotin scans NIOSH 5526 GC/FPD OVS-2 (SKC 226-30-16) 0.25-1.0 15-75 Varies - Store samples cold and analyze within 14 days of sampling.

Oxalic acid 144-62-7 OSHA PV 2115 IC GFF-37mm 1 100 10 -

Ozone 10028-15-6 OSHA ID-214 Wet Chem GFF-T21 (SKC 225-9014) 0.25-0.5 90-120 5 - Media has 28-day shelf-life, so allow time for filters to be made; see method if sulfur dioxide or nitrate present when sampling.

Paraffin wax 8002-74-2 OSHA PV 2047 GC/FID GFF-37mm 1 100 20 -

Parathion 56-38-2 OSHA 62 GC/FPD OVS-2 (SKC 226-30-16) 1 60 0.5 15

Particulate (respirable) NIOSH 0600 Gravimetric PVC-preweighed (cyclone determines 2-pc. or 3-pc. cassette) 75-1000 50 - Requires use of a cyclone; follow manufacturer’s instructions for flow rate.

Particulate (total) NIOSH 0500 Gravimetric PVC-preweighed-2pc 1.5-2.0 25-1000 50 -

Pentachlorophenol 87-86-5 OSHA 39 HPLC XAD7-T16 (w/GFF disc) (3 tube set is SKC 226-97) 0.2 48 1 - SKC set contains disc and tubes. See method for important sampling train details.

Pentanal 110-62-3 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.2-1.5 1-15 0.5 5 Store cold; flow rate/ volume from NIOSH 2016. See EPA method for more information on special sampling situations.

Pentane 109-66-0 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 2 2 1

600-14-6 OSHA 1016 GC/FID SG – washed & baked (226-183: set of 2 tubes) 0.05 (0.2 for STEL) 10 (3 for STEL) 1 42

EPA TO-10A GC/ECD PUF variable variable varies 29

Petroleum distillates 8002-05-9 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1 If available, submit bulk reference material in separate packaging.

Petroleum ether 8032-32-4 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 3 1 If available, submit bulk reference material in separate packaging.

Petroleum naphtha NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1 If available, submit bulk reference material in separate packaging.

Phenanthrene (also see PAH scans) 85-01-8 NIOSH 5506 HPLC PTFE-2µm/XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2

Phenanthrene (also see PAH scans) 85-01-8 OSHA 58 HPLC GFF-37mm 2 960 0.3 6

Phenol 108-95-2 NIOSH 2546 GC/FID XAD-7 (SKC 226-95) 0.01-0.1 1-24 3 25

Phenol 108-95-2 OSHA 32 HPLC XAD-7 (SKC 226-95) 0.1 24 3 26

Phenylenediamine o-, m-, p-, and/or total 106-50-3 OSHA 87 HPLC GFF-T3 (SKC 225-9004) 1 100 3 -

Phenyl ether 101-84-8 NIOSH 1617 GC/FID CT (SKC 226-01) 0.01-0.2 1-50 3 1

Phenyl ether-diphenyl mixture 8004-13-5 NIOSH 2013 GC/FID SG (SKC 226-10 or 226-15) 0.01-0.2 1-40 6 -

Phenyl glycidyl ether 122-60-1 NIOSH 1619 GC/FID CT (SKC 226-01) ≤1.0 80-150 4 -

Phosgene 75-44-5 OSHA 61 GC/NPD XAD2 -T1 (SKC 226-117 or ORBO 24) 1 240 2 - Store cold. Minimum sample batch is a sample and a field blank.

Phosphine 7803-51-2 OSHA 1003 ICP GFF / polyester-T18 (SKC 225-9018) 1.0-2.0 30-240 5 - Media requires special prep, so filters need to be ordered in advance. Media shelf life is 3 months.

Phosphoric acid also see acid scan 7664-38-2 NIOSH 7903 IC SG-T12 (SKC 226-10-03 OR ORBO 53) 0.2-0.5 3-100 8 3

Phosphoric acid also see acid scan 7664-38-2 OSHA ID-111 IC MCE 2 960 10 -

Phosphorus (particulate) 7723-14-0 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 25-2000 1 7 Do not exceed 2 mg of total dust on filter.

Phosphorus (vapor) 7723-14-0 NIOSH 7905 GC/FPD Tenax (SKC 226-35-03) 0.01-0.2 5-100 0.003 - Must be analyzed w/in 7 days after sampling.

Phthalic anhydride 85-44-9 OSHA 90 HPLC GFF (treated with veratrylamine) (SKC 225-9021) 1 75 1 - Media has a shelf life of 3

Pinene, alpha 80-56-8 NIOSH 1552 GC/FID CT (SKC 226-01) 0.01-0.2 2-30 2 1 Store cold.

Pinene, beta 127-91-3 NIOSH 1552 GC/FID CT (SKC 226-01) 0.01-0.2 2-30 2 1 Store cold.

Platinum 7440-06-4 NIOSH 7303 ICP/MS MCE 1.0-4.0 200-2000 1 - Do not exceed 2 mg of total dust on filter.

Polychlorobiphenyls (PCB) NIOSH 5503 GC/ECD GFF-13mm / Florisil (SKC 226-39) 0.05-0.2 1-50 0.1 -

Oil mist (or MWF) method includes particulate analysis

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5524.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5524.pdf)

Not a preferred method. Oil must be soluble in freon. Bulk reference material (oil) required; ship in separate packaging. Use PVC-PW, for total particulate, if bulk not soluble.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5526.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv211

5/pv2115.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

14/id214.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/pv204

7/2047.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

62/org062.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0600.pdf)

See handling instructions

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

39/org039.html)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Pentanedione, 2,3[View]

(https://www.osha.gov/dts/sltc/methods/validated/1016/1016.pdf)

Analyze w/in 17 days of sampling. Protect samples from light during & after sampling, using tube holders, aluminum foil, or other means. Store cold.

Pesticides (chlorinated)/PCBs also see pesticide scans

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

10ar.pdf)

Store cold; wrap in foil for shipment; lab must extract sample within 7 days of sampling. Lab does not stock PUF media. See method for more details.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2546.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

32/org032.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

87/org087.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1617.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2013.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1619.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

61/org061.html)

[View](https://www.osha.gov/dts/sltc/methods/mdt/mdt100

3/1003.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/id111/

id111.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7905.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

90/org090.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1552.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1552.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5503.pdf) Protect from light; transfer filter to glass vial w/ teflonlined cap.

EPA TO-10A GC/ECD PUF 1.0-5.0 240-7200 1 29

Polychlorobiphenyls (PCB) Wipes EPA 8082 GC/ECD N/A N/A Varies - Template often 100 cm2 . Dampen media with hexane and place in glass vial.

NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

OSHA 58 HPLC GFF-37mm 2 200-1000 0.3 6 Protect from light; after sampling: fold filter, wipe inside of cassette with filter, and transfer filter to vial w/ teflon-lined cap.

Potassium 7440-09-7 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-1000 10 7 Do not exceed 2 mg of total dust on filter.

Potassium hydroxide 1310-58-3 NIOSH 7401 Wet Chem PTFE-1µm 1.0-4.0 70-1000 30 20 Alkaline dust method.

Propane 74-98-6 OSHA PV2077 GC/FID Anasorb CMS (2 tubes) (ORBO 91) 0.1 5 3 12 Separate tubes after sampling. Cannot use regular charcoal tubes (226-01) or 3M badges.

Propionaldehyde also see aldehyde scans 123-38-6 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.03-1.5 1-15 0.5 5 Store cold; flow rate/volume from NIOSH 2016. See EPA method for more information on special sampling situations.

Propyl acetate, n- 109-60-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 2 1

Propyl alcohol,n- 71-23-8 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 4 1

Propyl cellosolve 2807-30-9 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.05 1-10 2 17

Propyl mercaptan, n- 107-03-9 NIOSH 2525 GC/FPD Chrm. 104 0.01-0.05 1-4 1 14

Propylene glycol 57-55-6 NIOSH 5523 GC/FID OVS-7 (SKC 226-57) 0.5-2.0 5-60 10 16 Store cold.

Propylene oxide 75-56-9 NIOSH 1612 GC/FID CT (SKC 226-01) 0.01-0.2 0.5-5.0 2 - Store cold. Notify lab if acetone or IPA present (possible interferences).

Propylene oxide 75-56-9 OSHA 88 GC/FID Anasorb 747 (226-81A) 0.1 5 2 - Store frozen, but cold shipment to lab not required.

Pyrene see also PAH scan 129-00-0 NIOSH 5506 HPLC PTFE-2µm / XAD-2 (SKC 226-30-04 or ORBO 43) 2 200-1000 3 2 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Pyrene see also PAH scan 129-00-0 OSHA 58 HPLC GFF-37mm 2 960 0.3 6 Store cold; protect from light; after sampling, transfer filter to vial w/ teflon-lined cap.

Pyrethrum 8003-34-7 NIOSH 5008 HPLC GFF-37mm 1.0-3.0 20-400 5 -

Pyridine 110-86-1 NIOSH 1613 GC/FID CT (SKC 226-01) 0.01-1.0 18-150 4 -

Quartz (see Silica, crystalline) NIOSH 7500 XRD PVC-PW 400-1000 20 34

Resorcinol 108-46-3 OSHA PV 2053 GC/FID OVS-7 (SKC 226-57) 1.0 60 10 -

Selenium 7782-86-6 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 13-2000 1 7 Do not exceed 2 mg of total dust on filter.

14808-60-7 NIOSH 7500 XRD 400-1000 10 34

Silica, crystalline Bulk sample 14808-60-7 NIOSH 7500 XRD Place sample in vial or ziplock baggie. N/A N/A 0.50% - Indicate possible interferences, such as calcite, on CoC.

Silicon 7440-21-3 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-1000 1 7 Do not exceed 2 mg of total dust on filter.

Silver 7440-22-4 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 250-2000 0.2 7 Do not exceed 2 mg of total dust on filter.

Sodium 7440-23-5 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 13-2000 10 7 Do not exceed 2 mg of total dust on filter.

Sodium azide 26628-22-8 OSHA ID-211 IC PVC 1 5 0.4 -

Sodium hydroxide 1310-73-2 NIOSH 7401 Wet Chem PTFE-1µm 1.0-4.0 70-1000 20 20

Stoddard solvent 8052-41-3 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1 If available, submit bulk reference material in separate packaging.

Strontium 7440-24-6 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 10-1000 1 7 Do not exceed 2 mg of total dust on filter.

Styrene 100-42-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-1.0 1-14 10 1

Styrene 100-42-5 OSHA 89 GC/FID CT-T4 (SKC 227-73 or ORBO 351) 0.05 12 5 - Cold shipment not required, but storage at reduced temperature recommended.

Sulfur dioxide also see sulfur oxides 7446-09-5 NIOSH 6004 IC MCE / Treated pad-T20 (SKC 225-9005) 0.5-1.5 4-200 4 - Do not exceed 2 mg of particulate loading on filter; see method if sulfuric acid analysis will be required.

Sulfur dioxide also see sulfur oxides 7446-09-5 OSHA ID-200 IC Carbon bead-T (SKC 226-80) 0.1 1.5-12 2.7 - -

Sulfur dioxide also see sulfur oxides 7446-09-5 OSHA ID-1011 IC SG-treated (AgNO3) & treated GFF (SKC 226-177) 0.05-0.5 7.5-12 4 39 Store cold. Use media from the same lot for each sample batch.

Polychlorobiphenyls (PCB) (7 aroclors) also see Pesticide scans

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

10ar.pdf)

Store cold; wrap in foil for shipment; lab must extract sample within 7 days of sampling. Lab does not stock PUF media. See method for more details.

[View](http://www3.epa.gov/epawaste/hazard/testmethods/

sw846/pdfs/8082a.pdf)Gauze pad, glass wool, or filter paper (whatman 40ashless)

Polynuclear Aromatic Hydrocarbons 17 PAHs

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

Polynuclear Aromatic Hydrocarbons 5 PAH's

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7401.pdf)

[View](https://www.osha.gov/dts/sltc/methods/partial/t-pv2077-01-9003-ch/t-pv2077-01-9003-ch.html)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2525.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5523.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1612.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

88/org088.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5506.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

58/org058.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5008.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1613.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf)

See handling instructions

Preweighed filter only if particulate required on same filter. Requires use of a cyclone for respirable dust collection. Follow manufacturer’s instructions for flow rate.

[View](https://www.osha.gov/dts/sltc/methods/partial/pv205

3/2053.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

Silica, crystalline 3 polymorphs: quartz, cristobalite, and tridymite

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf)

PVC preweighed (For respirable, use a cyclone, which determines 2-or 3-pc. cassette)

See handling instructions

Preweighed filter, only if particulate required on same filter. Requires use of a cyclone for respirable dust collection. Follow manufacturer’s instructions for flow rate. Indicate possible interferences, such as calcite, on CoC.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7500.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

11/id211.html)

Store samples cold (although cold shipment not required). Analysis of samples stored at room temperature required w/in 10 days.

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7401.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

89/org089.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6004.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

00/id200.html)

[View](https://www.osha.gov/dts/sltc/methods/validated/10

11/1011.pdf)

Sulfuric acid also see acid scan 7664-93-9 NIOSH 7903 IC SG-T12 (SKC 226-10-03 or ORBO 53) 0.2-0.5 3-100 10 -

Sulfuric acid also see acid scan 7664-93-9 OSHA ID-113 IC MCE 2 480 10 3 After sampling, remove filter from cassette and place in a glass for transport to the lab.

NIOSH 6004 IC MCE / Treated pad-T20 (SKC 225-9005) 0.5-1.5 4-200 4 - Do not exceed 2 mg of particulate loading on filter; see method if sulfuric acid analysis will be required.

Tellurium 13494-80-9 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 125-1000 1 - Do not exceed 2 mg of particulate loading on filter

26140-60-3 NIOSH 5021 GC/FID PTFE-2µm 1.0-3.0 2-30 10 - Ship samples in glass vials w/ teflon-lined caps.

79-27-6 NIOSH 2003 GC/FID SG (SKC 226-10 or 226-15) 0.2-1.0 50-100 10 1

79-34-5 NIOSH 1019 GC/FID Anasorb 747 (SKC 226-81A) 0.01-0.2 3-30 5 1

Tetrachloroethylene 127-18-4 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 3-40 4 1

Tetrahydrofuran 109-99-9 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-9.0 3 1

Thallium 7440-28-0 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 25-2000 1 7 Analysis for this metal not recommended for wipe samples. Do not exceed 2 mg of total dust on filter.

Tin 7440-31-5 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-500 1 7 Do not exceed 2 mg of total dust on filter.

Titanium 7440-32-6 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-100 1 7 Do not exceed 2 mg of total dust on filter.

Titanium dioxide 13463-67-7 NIOSH 0500 Gravimetric PVC-preweighed-2pc 1.5-2.0 25-1000 50 -

Tolualdehyde (total) 104-87-0 EPA TO-11 HPLC SG-T2 (SKC 226-119) 0.03-1.5 1-15 2 5 Store cold;

Toluene 108-88-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-8.0 2 1

Toluene 108-88-3 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-8.0 2 1

584-84-9 NIOSH 5521 HPLC Pip/Tol soln. (Imp) 1 5-500 0.2 33 Ship samples in glass vials w/ teflon-lined caps.

584-84-9 OSHA 42 HPLC GFF-T11 (SKC 225-9002) 1 15-240 0.2 4 Store cold; sample open-faced; protect from light.

91-08-7 NIOSH 5521 HPLC Pip/Tol soln.(Imp) 1 5-500 0.2 33 Ship samples in glass vials w/ teflon-lined caps.

91-08-7 OSHA 42 HPLC GFF-T11 (SKC 225-9002) 1 15 0.2 4 Store cold; sample open-faced; protect from light.

Toluidine, o- 95-53-4 NIOSH 2002 GC/FID SG (SKC 226-10 or 226-15) 0.02-1.0 10-150 3 18

Total hydrocarbons NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1

Tributyl phosphate 126-73-8 NIOSH 5034 GC/FPD MCE 1.0-3.0 2-100 0.5 -

Trichloroacetic acid 76-03-9 In-house method HPLC SG (SKC 226-10 or 226-15) ≤10 ≤0.2 10 -

Trichlorobenzene, total OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10 6 1

71-55-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-60 3 -

79-00-5 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 10-60 3 1

Trichloroethylene 79-01-6 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 1-30 4 1

Triethanolamine 102-71-6 OSHA PV 2141 GC/FID GFF-37mm 1 100 40 -

Triethylamine 121-44-8 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.1-1.0 3-30 1 9 Store cold.

Triethylenetetramine 112-24-3 NIOSH 2540 HPLC XAD2-T5 (SKC 226-30-18) 0.01-0.1 1-20 10 37

Triethylenetetramine 112-24-3 OSHA 60 HPLC XAD2-T5 (SKC 226-30-18) 0.1 10 10 37

Trimethylamine 75-50-3 NIOSH 2007 GC/NPD SG (SKC 226-10 or 226-15) 0.01-1.0 3-30 2 10 Store cold.

25551-13-7 OSHA 7 GC/FID CT (SKC 226-01) 0.2 2-30 6 1

Triphenyl phosphate 115-86-6 NIOSH 5038 GC/FPD MCE 1.0-3.0 10-400 0.5 -

Tungsten 7440-33-7 OSHA ID-213 ICP MCE 2 30-480 10 38

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7903.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

13/id113.html)

Sulfur oxides (SOx) (3 forms: sulfur dioxide, sulfate, sulfite)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/6004.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

Terphenyl (total, o, m, & p) each one reported is charged as a separate analyte

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5021.pdf)

Tetrabromoethane, 1,1,2,2 [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2003.pdf)

Tetrachloroethane, 1,1,2,2 [View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1019.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)OSHA 1001 is written for passive badges (SKC 575002). Lab will cite equivalent analytical method (OSHA 7).

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

[View](http://www3.epa.gov/ttnamti1/files/ambient/airtox/to-

11ar.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)Method OSHA 111 is written for passive monitors (SKC 575-002 or 3M 3520). Lab will cite equivalent analytical method

(OSHA 7).

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Toluene diisocyanate,2,4 (2,4-TDI) also see isocyanate scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5521.pdf)

Toluene diisocyanate,2,4 (2,4-TDI) also see isocyanate scans

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

42/org042.html)

Toluene diisocyanate,2,6 (2,6-TDI) also see isocyanate scans

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5521.pdf)

Toluene diisocyanate,2,6 (2,6-TDI) also see isocyanate scans

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

42/org042.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2002.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5034.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

Trichloroethane, 1,1,1[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

Trichloroethane, 1,1,2[View]

(https://www.osha.gov/dts/sltc/methods/organic/org007/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](https://www.osha.gov/dts/sltc/methods/partial/t-

pv2141/t-pv2141.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2540-2.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

60/org060.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/2007.pdf)

Trimethylbenzene (total, or individual isomers)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/5038.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id2

13/id213.html)

PVC can only be used for soluble tungsten. Special instructions for soluble – see method (Sec. 2.2.6) for details. For wipes, see method (Sec. 2.3) for special instructions and contact laboratory before collecting samples.

Turpentine 8006-64-2 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 1-10 10 1 If available, submit bulk reference material in separate packaging.

Vanadium 7440-62-2 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-2000 1 7 Do not exceed 2 mg of total dust on filter.

Vanadium 7440-62-2 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Vinyl acetate 108-05-4 NIOSH 1453 GC/FID Anasorb 747 (ORBO 90 or 92) 0.1-0.2 0.75-24 2 - Store cold.

Vinyl chloride 75-01-4 NIOSH 1007 GC/FID CT (SKC 226-01) (2 tubes) 0.05 0.7-5.0 2 1 Store cold; separate tubes after sampling.

Vinyl toluene (total) 2513-15-4 OSHA 7 GC/FID CT (SKC 226-01) ≤0.2 3-30 20 1

VM&P naphtha 8032-32-4 NIOSH 1550 GC/FID CT (SKC 226-01) 0.01-0.2 0.2-20 10 1 If available, submit bulk reference material in separate packaging.

Welding fume, total (as particulate) NIOSH 0500 Gravimetric PVC-preweighed 2 960 50 -

OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 1.0-3.0 250-1000 Varies 8

Xylene (total) 1330-20-7 OSHA 7 GC/FID CT (SKC 226-01) 0.01-0.2 2-23 4 1

Zinc 7440-66-6 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 1.0-4.0 5-200 1 7 Do not exceed 2 mg of total dust on filter.

Zinc 7440-66-6 OSHA ID-125G ICP MCE (or PVC-PW w/ total dust) 2 30-480 1 8 Welding fume method.

Zirconium 7440-67-7 NIOSH 7303 ICP MCE (or PVC-PW w/ total dust) 2 960 3 7

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1453.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1007.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/1550.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/0500.pdf)

Welding fume (scan 13 metals) also see previous page, or metals scans

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](https://www.osha.gov/dts/sltc/methods/organic/org0

07/org007.html)OSHA 1002 is written for passive badges (SKC 575002). Lab will cite equivalent analytical method (OSHA 7).

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

[View](https://www.osha.gov/dts/sltc/methods/inorganic/id1

25g/id125g.pdf)

[View](http://www.cdc.gov/niosh/docs/2003-154/pdfs/7303.pdf)

Some forms of zirconium are not soluble in the acid prep (such as zirconium oxide); contact laboratory for details. Do not exceed 2 mg of total dust on filter.

Analyte Name CAS Number Method*

Acenaphthene also see PAH scans 83-32-9 NIOSH 5506

Acenaphthylene also see PAH scans 208-96-8 NIOSH 5506

Acetaldehyde also see aldehyde scans 75-07-0 25 200 360 EPA TO-11

Acetaldehyde also see aldehyde scans 75-07-0 25 200 360 OSHA 68

Acetic acid 64-19-7 10 15 10 25 10 25 15 37 OSHA PV 2119

Acetic acid 64-19-7 10 15 10 25 10 25 15 37 NIOSH 1603

Acetic acid 64-19-7 10 15 10 25 10 25 15 37 NIOSH 2011

Acetoin 513-86-0 OSHA 1013

Acetoin 513-86-0 OSHA 1012

Acetone 67-64-1 25 500 1000 2400 250 590 OSHA 7

Acetonitrile 75-05-8 20 40 70 20 34 NIOSH 1606

Acetonitrile 75-05-8 20 40 70 20 34 OSHA 37

Acrolein 107-02-8 0.1 0.1 0.25 0.1 0.25 0.3 0.8 NIOSH 2501

Acrolein 107-02-8 0.1 0.25 0.1 0.25 0.3 0.8 OSHA 52

Acrylamide 79-06-1 0.03 0.3 0.03 OSHA PV 2004

Acrylamide 79-06-1 0.03 0.3 0.03 OSHA 21

Acrylic acid 79-10-7 2 2 6 OSHA PV 2005

Acrylic acid 79-10-7 2 2 6 OSHA 28

Acrylonitrile 107-13-1 2 2 1 10 NIOSH 1604

Acrylonitrile 107-13-1 2 2 1 10 OSHA 37

Aldrin 309-00-2 0.05 0.25 0.25 EPA TO-10A

Alkaline dust - NIOSH 7401

Allyl alcohol 107-18-6 0.5 2 5 2 5 4 10 OSHA 7

Allyl chloride 107-05-1 1 2 1 3 1 3 2 6 NIOSH 1000

Aluminum 7429-90-5 1 15 (total) 10 (total) NIOSH 7303

Aluminum oxide 1344-28-1 NIOSH 0500

141-43-5 NIOSH 2007

Ammonia 7664-41-7 25 35 50 35 25 18 35 27 NIOSH 6016

Ammonia 7664-41-7 25 35 50 35 25 18 35 27 OSHA ID-164

Amyl acetate,n- 628-63-7 100 525 100 525 OSHA 7

Aniline 62-53-3 2 5 19 NIOSH 2002

Anthracene also see PAH scans 120-12-7 NIOSH 5506

Anthracene also see PAH scans 120-12-7 OSHA 58

Antimony 7440-36-0 0.5 0.5 0.5 NIOSH 7303

Antimony 7440-36-0 0.5 0.5 0.5 OSHA ID-125G

Arsenic 7440-38-2 0.01 0.01 0.002 NIOSH 7303

Arsenic trioxide 1327-53-3 NIOSH 7901

Arsine (as Arsenic) 7784-42-1 0.005 0.05 0.2 0.002 NIOSH 6001

Asbestos 1332-21-4 0.1 f/cc NIOSH 7400A

Asbestos 1332-21-4 0.1 f/cc NIOSH 7402

8052-42-4 0.5 5 OSHA 58

Barium 7440-39-3 0.5 NIOSH 7303

Benzaldehyde also see aldehyde scans 100-52-7 EPA TO-11

Benzene 71-43-2 0.5 2.5 1 5 0.1 1 OSHA 7

ACGIH TWA PEL (ppm)*

ACGIH TWA PEL (mg/m3)*

ACGIH STEL (ppm)*

ACGIH STEL (mg/m3)*

OSHA TWA PEL (ppm)*

OSHA TWA PEL (mg/m3)*

OSHA STEL (ppm)*

OSHA STEL (mg/m3)*

NIOSH TWA REL (ppm)*

NIOSH TWA REL (mg/m3)*

NIOSH STEL (ppm)*

NIOSH STEL (mg/m3)*

Aminoethanol, 2

Asphalt fumes See coal tar pitch volatiles and/or benzene solubles

- NIOSH 5042

Benzo (a) anthracene also see PAH scans 56-55-3 NIOSH 5506

Benzo (a) pyrene also see PAH scans 50-32-8 NIOSH 5506

Benzo (a) pyrene also see PAH scans 50-32-8 OSHA 58

205-99-2 NIOSH 5506

Benzo (e) pyrene also see PAH scans 192-97-2 NIOSH 5506

191-24-2 NIOSH 5506

207-08-9 NIOSH 5506

Benzoyl peroxide 94-30-0 5 5 5 NIOSH 5009

Benzyl alcohol 100-51-6 OSHA PV 2009

Benzyl chloride 100-44-7 1 1 5 1 5 OSHA 7

Beryllium (air) 7440-41-7 0.00005 0.002 0.005 0.0005 NIOSH 7303

Beryllium (air) 7440-41-7 0.00005 0.002 0.005 0.0005 NIOSH 7303-MS

Beryllium (air) 7440-41-7 0.00005 0.002 0.005 0.0005 OSHA ID-125G

Beryllium (air) Wipe samples 7440-41-7 0.00005 0.002 0.005 0.0005 OSHA ID-125G

Beryllium (air) Wipe samples 7440-41-7 0.00005 0.002 0.005 0.0005 EPA 6010

Biphenyl 92-52-4 0.2 NIOSH 2530

Bis-(2-ethylhexyl) phthalate 117-81-7 OSHA 104

Bisphenol A 80-05-7 NIOSH P&CAM 333

Bisphenol A diglycidyl ether 1675-54-3 NIOSH P&CAM 333

Boron 7440-42-8 NIOSH 7303

Bromine 7726-95-6 0.1 0.2 0.1 0.7 0.1 0.7 0.3 2 NIOSH 6011

Bromochloromethane 74-97-5 NIOSH 1003

Bromoform 75-25-2 0.5 0.5 5 0.5 5 OSHA 7

106-99-0 2 1 5 OSHA 56

106-99-0 2 1 5 NIOSH 1024

Butane, n- 106-97-8 1000 800 1900 OSHA PV 2010

111-76-2 20 50 240 5 24 OSHA 7

Butyl acetate, n- 123-86-4 150 200 150 710 150 710 200 950 OSHA 7

Butyl acetate, s- 105-46-4 200 200 950 200 950 OSHA 7

Butyl acetate, t- 540-88-5 200 200 950 200 950 OSHA 7

Butyl acrylate 141-32-2 2 10 55 OSHA 7

Butyl acrylate 141-32-2 2 OSHA PV 2011

Butyl alcohol, n- 71-36-3 100 300 50 150 OSHA 7

Butyl alcohol, s- 78-92-2 150 450 100 305 150 455 OSHA 7

Butyl alcohol, t- 75-65-0 100 300 100 300 150 450 OSHA 7

Butyl carbitol 112-34-5 OSHA 7

Butyl carbitol acetate 98100-70-0 OSHA 7

Butyl cellosolve 111-76-2 OSHA 7

Butyl glycidyl ether, n- 2426-08-6 3 50 270 5.6 30 NIOSH 1616

Butyl mercaptan, n- 109-79-5 0.5 10 35 0.5 1.8 NIOSH 2542

Butylamine, n- 109-73-9 5 5 15 5 15 NIOSH 2010

Cadmium 7440-43-9 0.002 0.005 NIOSH 7303

Cadmium 7440-43-9 0.002 0.005 OSHA ID-125G

Calcium 7440-70-2 0.005 NIOSH 7303

Camphor 76-22-2 2 3 2 2 OSHA 7

Caprolactam 105-60-2 5 0.22 1 0.66 3 OSHA PV 2012

Benzene solubles (also see asphalt fumes and/or coal tar pitch volatiles)

Benzo (b) fluoranthene also see PAH scans

Benzo (g,h,i) perylene also see PAH scans

Benzo (k) fluoranthene also see PAH scans

Butadiene, 1,3

Butadiene, 1,3

Butoxyethanol, 2

Captan 133-06-2 5 5 NIOSH 5601

Carbaryl 63-25-2 0.5 5 5 OSHA 63

Carbaryl 63-25-2 0.5 5 5 NIOSH 5601

Carbon black 1333-86-4 3 3.5 3.5 NIOSH 5000

Carbon black 1333-86-4 3 3.5 3.5 OSHA ID-196

Carbon Disulfide 75-15-0 1 20 1 3 10 30 NIOSH 1600

Carbon tetrachloride 56-23-5 5 10 10 2 12.6 OSHA 7

Cellosolve 110-80-5 OSHA 7

Cellosolve acetate 111-15-9 OSHA 7

Chlordane 57-74-9 0.5 0.5 0.5 OSHA 67

Chlordane (alpha, gamma) 57-74-9 0.5 0.5 EPA TO-10A

Chlorine 7782-50-5 0.5 1 1 3 0.5 1.45 NIOSH 6011

Chlorine 7782-50-5 0.5 1 1 3 0.5 1.45 OSHA ID-101

Chlorobenzene 108-90-7 10 75 350 OSHA 7

74-97-5 200 200 1050 200 1050 OSHA 7

Chloroform 67-66-3 10 50 240 2 9.78 OSHA 7

Chlorpyrifos (Dursban) 2921-88-2 0.1 0.2 0.6 OSHA 62

Chromic acid 1333-82-0 0.005 0.001 OSHA ID-215

Chromium 7440-47-3 0.5 0.5 0.5 NIOSH 7303

Chromium 7440-47-3 0.5 0.5 0.5 OSHA ID-125G

Chromium, hexavalent (Cr+6) Air 18540-29-9 0.01 OSHA ID-215

Chromium, hexavalent (Cr+6) Air Wipe 18540-29-9 0.01 OSHA ID-215

Chrysene also see PAH scans 218-01-9 NIOSH 5506

Chrysene also see PAH scans 218-01-9 OSHA 58

65996-93-2 0.2 OSHA 58

Cobalt 7440-48-4 0.02 0.1 0.05 NIOSH 7303

Cobalt 7440-48-4 0.02 0.1 0.05 OSHA ID-125G

Cobalt 7440-48-4 0.02 0.1 0.05 OSHA ID-213

Copper 7440-50-8 0.2 1 1 NIOSH 7303

Copper 7440-50-8 0.2 1 1 OSHA ID-125G

Cresol (o,m,p) 1319-77-3 20 5 22 2.3 10 NIOSH 2546

Cresols, total 1319-77-3 20 5 22 2.3 10 OSHA 32

Crotonaldehyde also see Aldehyde scans 123-73-9 0.3 2 6 2 6 EPA TO-11

Cumene 98-82-8 50 50 245 50 245 OSHA 7

74-90-8 10 11 4.7 5 NIOSH 7904

74-90-8 10 11 4.7 5 OSHA ID-120

Cyanide (particulate) 57-12-5 NIOSH 7904

Cyanide (particulate) 57-12-5 OSHA ID-120

Cyclohexane 110-82-7 100 300 1050 300 1050 OSHA 7

Cyclohexanol 108-93-0 50 50 200 50 200 OSHA 7

Cyclohexanone 108-94-1 20 50 200 25 100 OSHA 7

Cyclohexene 110-83-8 300 300 1015 300 1015 OSHA 7

Cyclohexylamine 108-91-8 10 10 40 NIOSH 2010

Cyclohexylamine 108-91-8 10 10 40 OSHA PV 2016

72-55-9 EPA TO-10A

50-29-3 1 1 0.5 EPA TO-10A

Di-n-octyl phthalate 117-84-0 OSHA 104

Chlorobromomethane

Coal Tar Pitch Volatiles (CTPV) also see benzene solubles and/or asphalt fumes

Cyanide (gaseous) also see hydrogen cyanide

Cyanide (gaseous) also see hydrogen cyanide

DDE, 4,4'also see Pesticide scans

DDT, 4,4'also see Pesticide scans

Diacetone alcohol 123-42-2 50 240 50 240 OSHA 7

Diacetyl 431-03-8 0.01 0.02 OSHA 1013

Diacetyl 431-03-8 0.01 0.02 OSHA 1012

Diazinon 333-41-5 0.01 0.1 NIOSH 5600

Diazinon 333-41-5 0.01 0.1 OSHA 62

- OSHA PV 2019/2020/2021

53-70-3 NIOSH 5506

96-12-8 0.001 In-house method

Dibutyl phthalate 84-74-2 5 5 5 OSHA 104

75-34-3 100 100 400 100 400 OSHA 7

107-06-2 OSHA 7

75-35-4 OSHA 7

78-87-5 OSHA 7

Dichlorvos (DDVP) 62-73-7 0.1 1 1 OSHA 62

Diesel fuel 68334-30-5 100 NIOSH 1550

Diesel particulate 7440-44-0 NIOSH 5040

Diethanolamine 111-42-2 1 3 15 OSHA PV 2018

Diethyl ether 60-29-7 OSHA 7

Diethyl phthalate 84-66-2 5 5 OSHA 104

Diethylamine 109-89-7 5 15 25 75 10 30 25 75 NIOSH 2010

Diethylene glycol 111-46-6 10 NIOSH 5523

Diethylenetriamine 111-40-0 1 1 4 NIOSH 2540

Diethylenetriamine 111-40-0 1 1 4 OSHA 60

Diethylethanolamine 100-37-8 10 50 10 50 NIOSH 2007

Diisobutyl ketone 108-83-8 25 50 290 25 150 NIOSH 1300

Diisopropylamine 108-18-9 5 5 20 5 20 NIOSH 2010

Dimethyl acetamide 127-19-5 10 35 10 35 NIOSH 2004

Dimethyl adipate also see dibasic esters 627-93-0 OSHA PV 2019

Dimethyl-cyclohexylamine 98-94-2 NIOSH 2010

Dimethyl disulfide 624-92-0 10 In-house method

Dimethyl ethanolamine 108-01-0 NIOSH 2007

Dimethyl ethylamine 598-56-1 NIOSH 2007

Dimethyl formamide 68-12-2 10 10 30 10 30 NIOSH 2004

Dimethyl formamide 68-12-2 10 10 30 10 30 OSHA 66

Dimethyl glutarate also see dibasic esters 1119-40-0 OSHA PV 2020

Dimethyl phthalate 131-11-3 5 5 5 OSHA 104

106-65-0 OSHA PV 2021

Dimethyl sulfate 77-78-1 0.1 1 5 0.1 0.5 NIOSH 2524

Dimethyl sulfide 75-18-3 10 In-house method

99-97-8 NIOSH 2002

Dimethylamine 124-40-3 10 18 10 18 NIOSH 2010

Dimethylaniline 121-69-7 5 10 5 25 5 25 10 50 NIOSH 2002

123-91-1 20 100 360 1 3.6 OSHA 7

Dowanol DPM 34590-94-8 OSHA 7

Dowanol PM 107-98-2 OSHA 7

Dowanol PMA 108-65-6 OSHA 7

Dust (see particulate) - NIOSH 0500/0600

Dibasic esters mix of dimethyl adipate, dimethyl glutarate, and dimethyl succinate

Dibenzo (a,h)anthracene also see PAH scans

1,2-Dibromo3-chloropropane

Dichloroethane, 1,1

Dichloroethane, 1,2

Dichloroethylene, 1,1

Dichloropropane, 1,2(also called propylene dichloride)

Dimethyl succinate also see dibasic esters

Dimethyl-ptoluidine, n,n-

Dioxane, 1,4

Elemental carbon (diesel particulate) - NIOSH 5040

Endrin 72-20-8 0.1 0.1 0.1 EPA TO-10A

Epichlorohydrin 106-89-8 0.5 5 19 NIOSH 1010

141-43-5 3 6 3 6 3 8 6 15 NIOSH 2007

Ethyl acetate 141-78-6 400 400 1400 400 1400 OSHA 7

Ethyl acrylate 140-88-5 5 15 25 100 OSHA 7

Ethyl acrylate 140-88-5 5 15 25 100 OSHA 92

Ethyl alcohol 64-17-5 1000 1000 1900 1000 1900 OSHA 7

Ethyl bromide 74-96-4 5 200 890 NIOSH 1011

Ethyl carbitol 111-90-0 OSHA 7

Ethyl cellosolve 96231-36-6 OSHA 7

Ethyl cellosolve acetate 111-15-9 OSHA 7

7085-85-0 0.2 OSHA 55

Ethyl ether 60-29-7 400 500 400 1200 OSHA 7

763-69-9 OSHA 7

Ethyl mercaptan 75-08-1 0.5 10 25 0.5 1.3 NIOSH 2542

Ethyl parathion 56-38-2 OSHA 62

Ethyl silicate 78-10-4 10 100 850 10 85 NIOSH S-264

Ethylamine 75-04-7 5 15 10 18 10 18 NIOSH 2007

Ethylbenzene 100-41-4 20 100 435 100 435 125 545 OSHA 7

Ethylene dibromide 106-93-4 20 0.045 OSHA 7

Ethylene glycol 107-21-1 100 NIOSH 5523

Ethylene oxide 75-21-8 1 1 0.1 0.18 OSHA 1010

Ethylene oxide 75-21-8 1 1 0.1 0.18 OSHA 49

Ethylenediamine 107-15-3 10 10 25 10 25 NIOSH 2540

Ethylenediamine 107-15-3 10 10 25 10 25 OSHA 60

103-11-7 OSHA PV2026

Fibrous glass also see other fiber options NIOSH 7400B

Fluoranthene also see PAH scans 206-44-0 NIOSH 5506

Fluorene also see PAH scans 86-73-7 NIOSH 5506

Fluoride (gaseous) 7664-39-3 NIOSH 7902

Fluoride (gaseous) 7664-39-3 OSHA ID-110

Fluoride (particulate) 16984-48-8 2.5 NIOSH 7902

Fluoride (particulate) 16984-48-8 2.5 OSHA ID-110

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 NIOSH 2016

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 EPA TO-11

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 OSHA 52

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 NIOSH 3500

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 OSHA ID-205

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 OSHA 1007

Formaldehyde also see Aldehyde scans 50-00-0 0.3 0.75 2 0.016 NIOSH 3500

Formic Acid 64-18-6 5 10 5 9 5 9 NIOSH 2011

Freon 113 76-13-1 NIOSH 1006

Freon 114 76-14-2 NIOSH 1018

Freon 141B 1717-00-6 OSHA 7

Freon 22 75-46-6 OSHA 7

Furfural 98-01-1 2 5 20 OSHA 72

Ethanolamine (also called monoethanolamine)

Ethyl cyanoacrylate, 2

Ethyl-3-ethoxypropionate

Ethylhexyl acrylate, 2

Furfuryl alcohol 98-00-0 10 15 50 200 10 40 15 60 NIOSH 2505

gamma-BHC 58-89-9 EPA TO-10A

Glutaraldehyde 111-30-8 0.05 0.2 0.8 NIOSH 2532

Glutaraldehyde 111-30-8 0.05 0.2 0.8 OSHA 64

Halothane 151-67-7 50 2 16.2 OSHA 103

Heptane 142-82-5 400 500 500 2000 85 350 440 1800 OSHA 7

87-68-3 0.02 0.02 0.24 NIOSH 2543

Hexachloroethane 67-72-1 1 1 10 1 10 OSHA 7

Hexaldehyde also see Aldehyde scans 9012-63-9 EPA TO-11

822-06-0 0.005 0.005 0.035 0.02 0.14 NIOSH 5521

822-06-0 0.005 0.005 0.035 0.02 0.14 OSHA 42

124-09-4 NIOSH 2007

Hexane, n- 110-54-3 50 500 1800 500 1800 OSHA 7

Hexyl cellosolve 32167-24-1 OSHA 7

Hexylene glycol 107-41-5 25 25 125 In-house method

Hydrazine 301-01-2 0.01 1 1.3 0.03 0.04 OSHA 108

Hydrazoic acid 7782-79-8 OSHA ID-211

Hydrobromic acid also see acid scan 10035-10-6 3 10 3 10 NIOSH 7903

Hydrocarbons, total NIOSH 1550

Hydrochloric acid also see acid scan 7647-01-0 5 7 5 7 NIOSH 7903

Hydrofluoric acid also see acid scan 7664-39-3 5 7 5 7 NIOSH 7903

Hydrogen cyanide also see cyanide 74-90-8 4.7 10 11 4.7 5 NIOSH 6010

Hydrogen peroxide 7722-84-1 1 1 1.4 1 1.4 OSHA ID-006

Hydrogen sulfide 7783-06-4 1 5 20 10 NIOSH 6013

Hydrogen sulfide 7783-06-4 1 5 20 10 OSHA ID-1008

Hydrogenated MDI (H2MDI) 88504-76-1 OSHA PV2092

Hydroquinone 123-31-9 1 2 2 NIOSH 5004

Hydroquinone 123-31-9 1 2 2 OSHA PV 2094

193-39-5 NIOSH 5506

Inorganic Acid Scan also see scans NIOSH 7903

Iodine 7553-56-2 0.01 0.1 0.1 1 0.1 1 OSHA ID-212

Iron 7439-89-6 NIOSH 7303

Iron 7439-89-6 OSHA ID-125G

Isoamyl alcohol 123-51-3 100 125 100 360 100 360 125 450 OSHA 7

Isobutyl acetate 110-19-0 150 150 700 150 700 OSHA 7

Isobutyl alcohol 78-83-1 100 300 50 150 OSHA 7

Isophorone 78-59-1 5 25 140 4 23 OSHA 7

Isophorone diisocyanate (IPDI) 4098-71-9 0.005 0.005 0.045 0.02 0.18 OSHA 42

Isopropyl acetate 108-21-4 100 200 250 950 OSHA 7

Isopropyl alcohol 67-63-0 400 980 400 980 500 1225 OSHA 7

Isopropyl ether 108-20-3 250 310 500 2100 500 2100 OSHA 7

Isopropylamine 75-31-0 5 10 5 12 NIOSH 2007

Kerosene 8008-20-6 200 100 NIOSH 1550

Lanthanum 7439-91-0 NIOSH 7303

Lead Air samples 7439-92-1 0.05 0.05 0.05 NIOSH 7303

Lead Air samples 7439-92-1 0.05 0.05 0.05 NIOSH 7303-MS

Lead Air samples 7439-92-1 0.05 0.05 0.05 OSHA ID-125G

Hexachlorobutadiene

Hexamethylene diisocyanate (HDI) see isocyanate scan also

Hexamethylene diisocyanate (HDI) see isocyanate scan also

Hexamethylenediamine

Indeno (1,2,3-cd) pyrene also see PAH scans

Lead Wipe samples 7439-92-1 0.05 0.05 0.05 EPA 6010

Lead Paint chips 7439-92-1 0.05 0.05 0.05 EPA 6010

Limonene, d- 5989-27-5 OSHA 7

Lithium 7439-93-2 NIOSH 7303

Magnesium 7439-95-4 NIOSH 7303

Malathion 121-75-5 15 10 OSHA 62

Maleic anhydride 108-31-6 0.01 0.25 1 0.25 1 OSHA 25

Maleic anhydride 108-31-6 0.01 0.25 1 0.25 1 OSHA 86

Manganese 7439-96-5 0.02 5 1 3 NIOSH 7303

Manganese 7439-96-5 0.02 5 1 3 OSHA ID-125G

Mercury (vapor) 7439-97-6 0.01 0.1 0.05 NIOSH 6009

Mercury (vapor) 7439-97-6 0.01 0.1 0.05 OSHA ID-140

Mercury (particulate) 7439-97-6 0.01 0.1 0.1 OSHA ID-145F

NIOSH 5524

Metals-Welding Scan 13 metals OSHA ID-125G

Metals Scans 28 metals NIOSH 7303

Metals Scans Wipe Samples EPA 6010

Methacrylic acid 79-41-4 20 20 70 OSHA PV 2005

Methanol 67-56-1 200 250 NIOSH 2000

Methanol 67-56-1 200 250 OSHA 91

Methyl acrylate 96-33-3 2 10 35 10 35 OSHA 7

Methyl acrylate 96-33-3 2 10 35 10 35 OSHA 92

Methyl amyl ketone 110-43-0 50 100 465 100 465 OSHA 7

Methyl aniline 100-61-8 0.5 NIOSH 2002

Methyl bromide 74-83-9 1 20 80 OSHA PV 2040

Methyl butyl ketone 591-78-6 5 10 OSHA 7

Methyl cellosolve 109-86-4 25 80 0.1 0.3 OSHA 7

Methyl cellosolve acetate 110-49-6 25 120 0.1 0.5 OSHA 7

Methyl chloride 74-87-3 50 100 100 300 NIOSH 1001

Methyl ethyl ketone (MEK) 78-93-3 200 300 200 590 200 590 300 885 NIOSH 2555

Methyl ethyl ketone (MEK) 78-93-3 200 300 200 590 200 590 300 885 OSHA 7

Methyl formate 107-31-3 50 100 100 250 100 250 150 375 OSHA PV 2041

Methyl iodide 74-88-4 2 5 28 2 10 NIOSH 1014

Methyl isoamyl ketone 110-12-3 20 50 100 475 50 240 OSHA 7

Methyl isobutyl carbinol 108-11-2 25 40 25 100 25 100 40 165 OSHA 7

Methyl isobutyl ketone (MIBK) 108-10-1 20 75 100 410 50 205 75 300 OSHA 7

Methyl mercaptan 74-93-1 0.5 10 20 0.5 1 NIOSH 2542

Methyl methacrylate 80-62-6 50 100 100 410 100 410 NIOSH 2537

Methyl methacrylate 80-62-6 50 100 100 410 100 410 OSHA 94

Methyl parathion 298-00-0 0.02 0.2 OSHA 62

Methyl propyl ketone 107-87-9 150 OSHA 7

Methyl styrene 98-83-9 10 100 480 50 240 100 485 OSHA 7

Methyl tert-butyl ether (MTBE) 1634-04-4 OSHA 7

n-Methyl-2 pyrrolidone (nmp) 872-50-4 OSHA 7

n-Methyl-2 pyrrolidone (nmp) 872-50-4 NIOSH 1302

Methylamine 74-89-5 5 15 10 12 10 12 NIOSH 2007

Methylcyclohexane 108-87-2 400 500 2000 400 1600 NIOSH 2007

Metal-working fluids (MWF) method includes particulate analysis

101-68-8 0.005 0.02 0.2 0.005 0.05 0.02 0.2 NIOSH 5521

101-68-8 OSHA 47

Methylene chloride 75-09-2 50 25 125 OSHA 80

Methylene chloride 75-09-2 50 25 125 NIOSH 1005

Methylenedianiline, 4,4’-(MDA) 101-77-9 0.1 0.01 0.1 OSHA 7

Methylenedianiline, 4,4’-(MDA) 101-77-9 0.1 OSHA 57

Mineral spirits 68551-17-7 NIOSH 1550

Molybdenum 7439-98-7 0.5 15 NIOSH 7303

Molybdenum 7439-98-7 0.5 15 OSHA ID-125G

Morpholine 110-91-8 20 20 70 20 70 30 105 NIOSH 2010

Morpholine 110-91-8 20 20 70 20 70 30 105 OSHA PV 2123

Naphtha 8030-30-6 100 400 100 400 NIOSH 1550

Naphthalene also see PAH scans 91-20-3 10 10 50 10 50 15 75 OSHA 7

Naphthalene also see PAH scans 91-20-3 10 10 50 10 50 15 75 OSHA 35

Naphthalene also see PAH scans 91-20-3 10 10 50 10 50 15 75 NIOSH 5506

134-32-7 OSHA 93

Nickel 7440-02-0 0.1 1 0.015 NIOSH 7303

Nickel 7440-02-0 0.1 1 0.015 OSHA ID-125G

Nickel carbonyl 13463-39-3 0.05 0.001 0.007 0.001 0.007 NIOSH 6007

Nicotine 54-11-5 0.5 0.5 0.5 NIOSH 2544

Nicotine 54-11-5 0.5 0.5 0.5 NIOSH 2551

Nitric acid also see acid scan 7697-37-2 2 4 2 5 2 5 4 10 NIOSH 7903

Nitric oxide 10102-43-9 25 25 30 25 30 OSHA ID-190

Nitrobenzene 98-95-3 1 1 5 1 5 NIOSH 2005

Nitrogen dioxide (NO2) 10102-44-0 0.2 5 9 1 1.5 OSHA ID-182

Nitrogen oxides (NO/NO2) NIOSH 6014

Nitroglycerin 55-63-0 0.05 0.2 2 0.1 NIOSH 2507

Nitromethane 75-52-5 20 100 250 NIOSH 2527

Nuisance dust (respirable) NIOSH 0600

Nuisance dust (total) NIOSH 0500

Octane 111-65-9 300 500 2350 75 350 385 1800 OSHA 7

Oil mist (as particulate) 8012-95-1 NIOSH 0500

8012-95-1 NIOSH 5524

Oil mist (mineral) 8012-95-1 5 5 10 NIOSH 5524

Organotins also see organotin scans NIOSH 5526

Oxalic acid 144-62-7 1 2 1 1 2 OSHA PV 2115

Ozone 10028-15-6 0.05 0.1 0.2 0.1 0.2 OSHA ID-214

Paraffin wax 8002-74-2 2 2 OSHA PV 2047

Parathion 56-38-2 0.05 0.1 0.05 OSHA 62

Particulate (respirable) 5 NIOSH 0600

Particulate (total) 15 NIOSH 0500

Pentachlorophenol 87-86-5 0.5 1 0.5 0.5 OSHA 39

Pentanal 110-62-3 EPA TO-11

Pentane 109-66-0 1000 1000 2950 120 350 610 1800 OSHA 7

600-14-6 OSHA 1016

EPA TO-10A

Petroleum distillates 8002-05-9 500 2000 350 1800 NIOSH 1550

Methylene bisphenyl isocyanate (MDI) also see isocyanate scan

Methylene bisphenyl isocyanate (MDI) also see isocyanate scan

Naphthylamine, 2or 1

Oil mist (or MWF) method includes particulate analysis

Pentanedione, 2,3

Pesticides (chlorinated)/PCBs also see pesticide scans

Petroleum ether 8032-32-4 NIOSH 1550

Petroleum naphtha NIOSH 1550

Phenanthrene (also see PAH scans) 85-01-8 NIOSH 5506

Phenanthrene (also see PAH scans) 85-01-8 OSHA 58

Phenol 108-95-2 5 5 19 5 19 15.6 60 NIOSH 2546

Phenol 108-95-2 5 5 19 5 19 15.6 60 OSHA 32

Phenylenediamine o-, m-, p-, and/or total 106-50-3 0.1 0.1 0.1 OSHA 87

Phenyl ether 101-84-8 1 2 1 7 1 7 NIOSH 1617

Phenyl ether-diphenyl mixture 8004-13-5 1 7 1 7 NIOSH 2013

Phenyl glycidyl ether 122-60-1 0.1 10 60 1 6 NIOSH 1619

Phosgene 75-44-5 0.1 0.1 0.4 0.1 0.4 0.2 0.8 OSHA 61

Phosphine 7803-51-2 0.3 1 0.3 0.4 0.3 0.4 1 1 OSHA 1003

Phosphoric acid also see acid scan 7664-38-2 1 3 1 1 3 NIOSH 7903

Phosphoric acid also see acid scan 7664-38-2 1 3 1 1 3 OSHA ID-111

Phosphorus (particulate) 7723-14-0 0.1 0.1 NIOSH 7303

Phosphorus (vapor) 7723-14-0 NIOSH 7905

Phthalic anhydride 85-44-9 1 2 12 1 6 OSHA 90

Pinene, alpha 80-56-8 NIOSH 1552

Pinene, beta 127-91-3 NIOSH 1552

Platinum 7440-06-4 0.002 1 NIOSH 7303

Polychlorobiphenyls (PCB) NIOSH 5503

EPA TO-10A

Polychlorobiphenyls (PCB) Wipes EPA 8082

NIOSH 5506

OSHA 58

Potassium 7440-09-7 NIOSH 7303

Potassium hydroxide 1310-58-3 2 2 NIOSH 7401

Propane 74-98-6 1000 1800 1000 1800 OSHA PV2077

Propionaldehyde also see aldehyde scans 123-38-6 20 EPA TO-11

Propyl acetate, n- 109-60-4 200 250 200 840 200 840 250 1050 OSHA 7

Propyl alcohol,n- 71-23-8 100 200 500 200 500 250 625 OSHA 7

Propyl cellosolve 2807-30-9 OSHA 7

Propyl mercaptan, n- 107-03-9 NIOSH 2525

Propylene glycol 57-55-6 NIOSH 5523

Propylene oxide 75-56-9 2 100 240 NIOSH 1612

Propylene oxide 75-56-9 2 100 240 OSHA 88

Pyrene see also PAH scan 129-00-0 NIOSH 5506

Pyrene see also PAH scan 129-00-0 OSHA 58

Pyrethrum 8003-34-7 5 5 5 NIOSH 5008

Pyridine 110-86-1 1 5 15 5 15 NIOSH 1613

Quartz (see Silica, crystalline) NIOSH 7500

Resorcinol 108-46-3 10 20 10 45 20 90 OSHA PV 2053

Selenium 7782-86-6 0.2 0.2 0.2 NIOSH 7303

14808-60-7 0.025 0.05 NIOSH 7500

Silica, crystalline Bulk sample 14808-60-7 0.025 0.05 NIOSH 7500

Silicon 7440-21-3 5 5 NIOSH 7303

Silver 7440-22-4 0.01 0.01 0.01 NIOSH 7303

Polychlorobiphenyls (PCB) (7 aroclors) also see Pesticide scans

Polynuclear Aromatic Hydrocarbons 17 PAHs

Polynuclear Aromatic Hydrocarbons 5 PAH's

Silica, crystalline 3 polymorphs: quartz, cristobalite, and tridymite

Sodium 7440-23-5 NIOSH 7303

Sodium azide 26628-22-8 0.11 0.29 0.1 0.3 OSHA ID-211

Sodium hydroxide 1310-73-2 2 2 2 NIOSH 7401

Stoddard solvent 8052-41-3 100 500 2900 350 1800 NIOSH 1550

Strontium 7440-24-6 NIOSH 7303

Styrene 100-42-5 20 40 100 50 215 100 425 OSHA 7

Styrene 100-42-5 20 40 100 50 215 100 425 OSHA 89

Sulfur dioxide also see sulfur oxides 7446-09-5 0.25 5 13 2 5 5 13 NIOSH 6004

Sulfur dioxide also see sulfur oxides 7446-09-5 0.25 5 13 2 5 5 13 OSHA ID-200

Sulfur dioxide also see sulfur oxides 7446-09-5 0.25 5 13 2 5 5 13 OSHA ID-1011

Sulfuric acid also see acid scan 7664-93-9 0.2 1 1 NIOSH 7903

Sulfuric acid also see acid scan 7664-93-9 0.2 1 1 OSHA ID-113

NIOSH 6004

Tellurium 13494-80-9 0.1 0.1 0.1 NIOSH 7303

26140-60-3 5 1 9 0.5 5 NIOSH 5021

79-27-6 0.1 NIOSH 2003

79-34-5 1 5 35 1 7 NIOSH 1019

Tetrachloroethylene 127-18-4 25 100 100 OSHA 7

Tetrahydrofuran 109-99-9 50 100 200 590 200 590 250 735 OSHA 7

Thallium 7440-28-0 0.02 0.1 0.1 NIOSH 7303

Tin 7440-31-5 2 2 2 NIOSH 7303

Titanium 7440-32-6 NIOSH 7303

Titanium dioxide 13463-67-7 10 15 NIOSH 0500

Tolualdehyde (total) 104-87-0 EPA TO-11

Toluene 108-88-3 20 200 100 375 150 560 OSHA 7

Toluene 108-88-3 20 200 100 375 150 560 OSHA 7

584-84-9 0.005 0.02 0.02 0.14 NIOSH 5521

584-84-9 0.005 0.02 0.02 0.14 OSHA 42

91-08-7 0.005 0.02 NIOSH 5521

91-08-7 0.005 0.02 OSHA 42

Toluidine, o- 95-53-4 2 5 22 NIOSH 2002

Total hydrocarbons NIOSH 1550

Tributyl phosphate 126-73-8 5 5 0.2 2.5 NIOSH 5034

Trichloroacetic acid 76-03-9 0.5 1 7 In-house method

Trichlorobenzene, total OSHA 7

71-55-6 OSHA 7

79-00-5 10 10 45 10 45 OSHA 7

Trichloroethylene 79-01-6 10 25 100 OSHA 7

Triethanolamine 102-71-6 5 OSHA PV 2141

Triethylamine 121-44-8 0.5 1 25 100 NIOSH 2007

Triethylenetetramine 112-24-3 NIOSH 2540

Triethylenetetramine 112-24-3 OSHA 60

Trimethylamine 75-50-3 5 15 10 24 15 36 NIOSH 2007

25551-13-7 25 OSHA 7

Triphenyl phosphate 115-86-6 3 3 3 NIOSH 5038

Tungsten 7440-33-7 1 3 5 10 OSHA ID-213

Turpentine 8006-64-2 20 100 560 100 560 NIOSH 1550

Sulfur oxides (SOx) (3 forms: sulfur dioxide, sulfate, sulfite)

Terphenyl (total, o, m, & p) each one reported is charged as a separate analyte

Tetrabromoethane, 1,1,2,2

Tetrachloroethane, 1,1,2,2

Toluene diisocyanate,2,4 (2,4-TDI) also see isocyanate scans

Toluene diisocyanate,2,4 (2,4-TDI) also see isocyanate scans

Toluene diisocyanate,2,6 (2,6-TDI) also see isocyanate scans

Toluene diisocyanate,2,6 (2,6-TDI) also see isocyanate scans

Trichloroethane, 1,1,1

Trichloroethane, 1,1,2

Trimethylbenzene (total, or individual isomers)

Vanadium 7440-62-2 NIOSH 7303

Vanadium 7440-62-2 OSHA ID-125G

Vinyl acetate 108-05-4 10 15 4 15 NIOSH 1453

Vinyl chloride 75-01-4 1 1 NIOSH 1007

Vinyl toluene (total) 2513-15-4 50 100 100 480 100 480 OSHA 7

VM&P naphtha 8032-32-4 350 NIOSH 1550

Welding fume, total (as particulate) NIOSH 0500

OSHA ID-125G

Xylene (total) 1330-20-7 OSHA 7

Zinc 7440-66-6 NIOSH 7303

Zinc 7440-66-6 OSHA ID-125G

Zirconium 7440-67-7 5 10 NIOSH 7303

Welding fume (scan 13 metals) also see previous page, or metals scans

Scan Name Analyte List CAS Numbers RL (ug) Method* Analytical Technique Sampling Media Flow Rates (Lpm) Volume (L) Notes*

Aldehydes Acetaldehyde 75-07-0 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Acetone 67-64-1 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Benzaldehyde 100-52-7 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Butyraldehyde 123-72-8 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Butanone, 2-(MEK) 78-93-3 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Crotonaldehyde 4170-30-3 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Formaldehyde 50-00-0 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Hexaldehyde 66-25-1 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Methacrolein 78-85-3 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Pentanal (valderaldehyde) 110-62-3 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Propionaldehyde 123-38-6 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Aldehydes Tolualdehyde (Total) 104-87-0 EPA TO-11 HPLC 0.03-1.5 L/min 1-15 L

Amines 75-04-7 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines Dimethylamine 124-40-3 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines Diethylamine 109-89-7 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines Methylamine 74-89-5 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines 109-73-9 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines Cyclohexylamine 108-91-8 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines Isopropylamine, n- 75-31-0 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

Amines Triethylamine 122-44-8 NIOSH 2010 GC/NPD Silica gel tube (SKC 226-10 or 226-15) 0.01 - 1.0 L/min 3-30 L Store samples cold.

BETX Benzene 71-43-2 NIOSH 1501 GC/MS < 0.2 L/min < 10 L Store samples cold.

BETX Ethyl benzene 100-41-4 NIOSH 1501 GC/MS < 0.2 L/min < 10 L Store samples cold.

BETX Toluene 108-88-3 NIOSH 1501 GC/MS < 0.2 L/min < 10 L Store samples cold.

BETX Xylenes (o,m,p) 1330-20-7 NIOSH 1501 GC/MS < 0.2 L/min < 10 L Store samples cold.

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

Treated silica gel tube (DNPH) (SKC 226-119) or badges:AT 571; SKC UMEx100

Store samples cold. When sampling on tubes (SKC 226-119), use formaldehyde (NIOSH 2016) guidelines. See EPA method, if using DNPH-treated cartridges. Can also use passive badges (AT 571 or SKC UMEx 100)

EthylamineDimethylamineDiethylamineMethylamine

ButylamineCyclohexylamine

Isopropylamine, n-Triethylamine

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Inorganic Acids 10035-10-6 NIOSH 7903 IC 0.2 - 0.3 L/min 3-100 L

Inorganic Acids Hydrochloric acid 7647-01-0 NIOSH 7903 IC 0.2 - 0.3 L/min 3-100 L

Inorganic Acids Hydrofluoric acid 7664-39-3 NIOSH 7903 IC 0.2 - 0.3 L/min 3-100 L

Inorganic Acids Nitric acid 7697-37-2 NIOSH 7903 IC 0.2 - 0.3 L/min 3-100 L

Inorganic Acids Phophoric acid 7664-38-2 NIOSH 7903 IC 0.2 - 0.3 L/min 3-100 L

Inorganic Acids Sulfuric acid 7664-93-9 NIOSH 7903 IC 0.2 - 0.3 L/min 3-100 L

Isocyanates Methylene bisphenyl isocyanate 101-68-8 OSHA 42/47 HPLC 1.0 L/min 15 - 240 L

Isocyanates Hexamethylene diisocyanate 822-06-0 OSHA 42/47 HPLC 1.0 L/min 15 - 240 L

Isocyanates Toluene diisocyanate, 2,4- 584-84-9 OSHA 42/47 HPLC 1.0 L/min 15 - 240 L

Isocyanates Toluene diisocyanate, 2,6- 91-08-7 OSHA 42/47 HPLC 1.0 L/min 15 - 240 L

Metals Aluminum 7429-90-5 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Antimony 7440-36-0 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Arsenic 7440-38-2 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Barium 7440-39-3 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Beryllium 7440-41-7 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Cadmium 7440-43-9 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Calcium 7440-70-2 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Chromium 7440-47-3 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Cobalt 7440-48-4 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Copper 7440-50-8 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Iron 7439-89-6 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Lead 7439-92-1 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Magnesium 7439-95-4 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Manganese 7439-96-5 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Nickel 7440-02-0 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Hydrobromic acidHydrochloric acidHydrofluoric acid

Nitric acidPhosphoric acid

Sulfuric acid

Treated silica gel tube (water-washed) (SKC 226-10-03)

Treated silica gel tube (water-washed) (SKC 226-10-03)

Treated silica gel tube (water-washed) (SKC 226-10-03)

Treated silica gel tube (water-washed) (SKC 226-10-03)

Treated silica gel tube (water-washed) (SKC 226-10-03)

Treated silica gel tube (water-washed) (SKC 226-10-03)

Treated glass fiberfilter (GFF)

(SKC 225-9002)

Store samples cold and protect samples from light.Sample open-faced.

Flow rate 1.0 Lpm; volume 15 liters (maximum is 240 liters).Recommendation: Immediately after sampling, transfer filter to amber vial containing DMSO/ACN (helps to stabilize

MDI).

Treated glass fiberfilter (GFF)

(SKC 225-9002)

Store samples cold and protect samples from light.Sample open-faced.

Flow rate 1.0 Lpm; volume 15 liters (maximum is 240 liters).Recommendation: Immediately after sampling, transfer filter to amber vial containing DMSO/ACN (helps to stabilize

MDI).

Treated glass fiberfilter (GFF)

(SKC 225-9002)

Store samples cold and protect samples from light.Sample open-faced.

Flow rate 1.0 Lpm; volume 15 liters (maximum is 240 liters).Recommendation: Immediately after sampling, transfer filter to amber vial containing DMSO/ACN (helps to stabilize

MDI).

Treated glass fiberfilter (GFF)

(SKC 225-9002)

Store samples cold and protect samples from light.Sample open-faced.

Flow rate 1.0 Lpm; volume 15 liters (maximum is 240 liters).Recommendation: Immediately after sampling, transfer filter to amber vial containing DMSO/ACN (helps to stabilize

MDI).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

Metals Potassium 7440-09-7 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Selenium 7782-86-6 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Sodium 7440-23-5 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Strontium 7440-24-6 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Thallium 7440-28-0 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Vanadium 7440-62-2 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals Zinc 7440-66-6 NIOSH 7303 ICP/MS 2.0 L/min 960 L

Metals (Welding Fumes) Aluminum 7429-90-5 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Antimony 7440-36-0 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Beryllium 7440-41-7 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Cadmium 7440-43-9 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Chromium 7440-47-3 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Cobalt 7440-48-4 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Copper 7440-50-8 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Iron 7439-89-6 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Lead 7439-92-1 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Manganese 7439-96-5 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Molybdenum 7439-98-7 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Nickel 7440-02-0 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Vanadium 7440-62-2 NIOSH 7303 ICP 2 L/min 960 L

Metals (Welding Fumes) Zinc 7440-66-6 NIOSH 7303 ICP 2 L/min 960 L

Pesticides Aldrin 309-00-2 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides BHC, alpha- 319-84-6 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides BHC, beta- 319-85-7 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides BHC, delta- 319-86-8 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides BCH, gamma 58-89-9 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

MCE filter(or, use preweighed PVC ifalso requesting total dust)

If total welding fume (as particulate) will also be tested on the same filter, we recommend collection on a preweighed PVC filter (vs. MCE).

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Pesticides Chlordane, alpha 5103-71-9 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Chlordane, gamma 5103-74-2 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides DDD, 4',4'- 72-54-8 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides DDE, 4',4'- 72-55-9 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides DDT, 4',4'- 50-29-3 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Dieldrin 60-57-1 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Endosulfan I 959-98-8 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Endosulfan II 33213-65-9 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Endosulfan sulfate 1031-07-8 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Endrin 72-20-8 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Endrin aldehyde 7421-93-4 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Endrin ketone 53494-70-5 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Heptachlor 76-44-8 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Heptachlor epoxide 1024-57-3 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Methoxychlor 72-43-5 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides Toxaphene 8001-35-2 EPA TO-10 GC/ECD PUF tube 1.0 - 5.0 L/min 240 - 7200 L

Pesticides 86-50-0 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Chlorpyrofos (Dursban) 2921-88-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Diazinon 333-41-5 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Dicrotophos 141-66-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Disulfoton 298-04-4 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Ethion 563-12-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Ethoprop 13194-48-4 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Sampling media must be ordered directly from SKC.Store samples cold and wrap in foil for shipment. Lab must extract sample within 7 days of sampling.

Azinphos methylChlorpyrifos (Dursban)

DiazinonDicrotophosDisulfoton

EthionEthoprop

FenamiphosFonofos

MalathionMethamidophos

MevinphosMethyl parathionMonocrotophos

ParathionPhorateRonnel

SulprofosTerbufos

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

Pesticides Fenamiphos 2224-92-6 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Fonofos 944-22-9 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Malathion 121-75-5 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Methamidophos 10265-92-6 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Mevinphos 26718-65-0 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Methyl parathion 56-38-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Monocrotophos 6923-22-4 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Parathion 56-38-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Phorate 298-02-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Ronnel 299-84-3 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Sulprofos 35400-43-2 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

Pesticides Terbufos 13071-79-9 NIOSH 5600 GC/FPD 0.2 - 1.0 L/min 12 - 60 L

120-12-7 OHSA 58 HPLC 2.0 L/min 200-1000 L

Benzo (a) pyrene 50-32-8 OHSA 58 HPLC 2.0 L/min 200-1000 L

Chrysene 218-01-9 OHSA 58 HPLC 2.0 L/min 200-1000 L

Phenanthrene 85-01-8 OHSA 58 HPLC 2.0 L/min 200-1000 L

Pyrene 129-00-0 OHSA 58 HPLC 2.0 L/min 200-1000 L

83-32-9 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Acenphthylene 208-96-8 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Anthracene 120-12-7 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Benzo(a)anthracene 56-55-3 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Benzo(a)pyrene 50-32-8 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Benzo(b)fluoranthene 205-99-2 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

OVS-2 tube(SKC 226-30-16)

PAH's (polynuclear aromatic hydrocarbons)

AnthraceneBenzo(a)pyrene

ChrysenePhenanthrene

Pyrene

Glass Fiber Filter(GFF-37 mm)

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

Glass Fiber Filter(GFF-37 mm)

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

Glass Fiber Filter(GFF-37 mm)

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

Glass Fiber Filter(GFF-37 mm)

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

Glass Fiber Filter(GFF-37 mm)

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

AcenaphtheneAcenaphthylene

AnthraceneBenzo(a)anthracene

Benzo(a)pyreneBenzo(b)fluoranthene

Benzo(e)pyreneBenzo(ghi)perylene

Benzo(k)fluorantheneChrysene

Dibenzo(a,h)anthraceneFluoranthene

FluoreneIndeno(1,2,3cd)pyrene

NaphthalenePhenanthrene

Pyren

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

Benzo(e)pyrene 192-97-2 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Benzo(ghi)perylene 191-24-2 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Benzo(k)fluoranthene 207-08-9 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Chrysene 218-01-9 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Dibenzo(a,h)anthracene 53-70-3 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Fluoranthene 206-44-0 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Fluorene 86-73-7 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Indeno(1,2,3)pyrene 193-39-5 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Naphthalene 91-20-3 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Phenanthrene 85-01-8 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Pyrene 129-00-0 NIOSH 5506 HPLC 2.0 L/min 200-1000 L

Volatiles Acetone 67-64-1 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Benzene 71-43-2 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Butyl acetate, n- 123-86-4 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Chlorobenzene 108-90-7 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Chloroform 67-66-3 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Ethanol 64-17-5 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles 2-Ethoxy ethyl acetate 111-15-9 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Ethyl acetate 141-78-6 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Ethylbenzene 100-41-4 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Hexane, n- 110-54-3 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Isobutanol 78-83-1 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Isopropanol 67-63-0 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Methylene chloride 75-09-2 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Methyl ethyl ketone 78-93-3 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Methyl isobutyl ketone 108-10-1 OSHA-7 GC/MS < 0.2 L/min < 10 L

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

PAH's (polynuclear aromatic hydrocarbons)

PTFE -2 µm"XAD-2 Tube

(SKC 226-30-04 or ORBO 43)""PTFE - 2 µm / XAD-2 Tube

sampling train"

Store samples cold. Protect from light. After sampling, remove filter from cassette, fold and use to wipe inside of cassette, then tranfer the filter to a glass vial with a teflon-lined cap

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Volatiles Styrene 100-42-5 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Tetrahydrofuran 109-99-9 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Tetrachloroethylene 127-18-4 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Toluene 108-88-3 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Trichloroethane, 1,1,1- 71-55-6 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Trichloroethylene 79-01-6 OSHA-7 GC/MS < 0.2 L/min < 10 L

Volatiles Total xylenes (o,m,p) 1330-20-7 OSHA-7 GC/MS < 0.2 L/min < 10 L

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Charcoal Tube(SKC 226-01)

Category Test – Method Information Comments

Fiber Counts - Air PCM (Phase-Contrast Microscopy) Often used for man-made fibers

Fiber Counts - Air PCM (Phase-Contrast Microscopy) NIOSH 7400 B Rules Often used for man-made fibers

Fiber Counts - Air TEM (Transmission Electron Microscopy) NIOSH 7402

Fiber Counts - Air TEM (Transmission Electron Microscopy) AHERA

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116 Building material, construction material, etc.

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116 Semi-quantitative

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116 Full quantitative

NIOSH 7400 A Rules

Normally used for personal exposure or PCMconfirmation

Normally used for building clearance;Additional Grid Openings for Sensitivity

Asbestos -bulk solids

Your basic asbestos test for identifying and quantifying asbestos fibers

Asbestos -bulk solids

Point-counting by PLM (400 points)(Routine PLM analysis, above)

Asbestos -bulk solids

Point-counting by PLM (1000 points)(Routine PLM analysis, above)

Asbestos -bulk solids

New York Method – Stratified Point Count by NY 198.1

Asbestos -bulk solids

New York Method – PLM Non-Organically Bound (NOB) Materials bymethod NY 198.1

Asbestos -bulk solids

Asbestos is identified and reported as one of three results,

either non-detect, < 1%, or > 1%

Asbestos -bulk solids

Asbestos is identified and quantified to the nearest 0.1%

PLM (Polarized Light Microscopy); Method EPA 600/R-93/116

Asbestos - Water TEM Drinking water, method EPA 100.2.

PLM/MC – Polarized Light Microscopy / Materials Characterization NA

TEM/MC – Transmission Electron Microscopy / Materials Characterization NA

Asbestos -bulk solids

New York Method – Non-Organically Bound (NOB) Materials by Method NY 198.4

Holding time is 48 hours, so call laboratory before collecting

samples

MaterialsCharacterization –

Bulk SolidsUses optical properties of light to identify larger

particles

MaterialsCharacterization –

Bulk Solids

Morphology, selected area electron diffraction (SAED) and

energy dispersive spectroscopy (EDS). Uses elemental

chemistry and crystallinity to identify very small particles—

less than 10 µm

Analysis Matrix Reporting Units

Total Spore Count 30-150 L No. of fungal structures/m3

Direct Spore Count Qualitative fungal ID

Direct Spore Count Dust 0.5 g Qualitative fungal ID

Direct Spore Count Liquid 50-100 mL Qualitative fungal ID

Direct Spore Count Swab Qualitative fungal ID

Direct Spore Count Tape Lift 1.5 in. tape length Qualitative fungal ID

RecommendedSample Size*

Special HandlingInstructions

Air(Using Air-O-Cell,

Allergenco, Burkard, or othersamplers)

Ship samples in slide casesor ziplock baggies, and place

in cooler or box (cold packnot necessary) with protective

wrapping. Samples shouldbe received within 2 days of

sampling

Bulk(Building materials, ceiling

tile, drywall)20 g or 1-4 in2

Ship samples in slide casesor ziplock baggies, and place

in cooler or box (cold packnot necessary) with protective

wrapping. Samples shouldbe received within 2 days of

sampling.Ship samples in slide cases

or ziplock baggies, and placein cooler or box (cold pack

not necessary) with protectivewrapping. Samples should

be received within 2 days ofsampling.

Ship samples in slide casesor ziplock baggies, and place

in cooler or box (cold packnot necessary) with protective

wrapping. Samples shouldbe received within 2 days of

sampling.

1-4 in2

Ship samples in slide casesor ziplock baggies, and place

in cooler or box (cold packnot necessary) with protective

wrapping. Samples shouldbe received within 2 days of

sampling.Ship samples in slide cases

or ziplock baggies, and placein cooler or box (cold pack

not necessary) with protectivewrapping. Samples should

be received within 2 days ofsampling.

Filters Filters Description Typical Analytes

Filter GFF-37mm Glass Fiber Filter (37 mm) Triethanolamine

Filter GFF-13mm PCBs (part of sampling train)

Filter GFF-T3 Hydrazine; 4,4-MDA

Filter GFF-T6 Mercaptans (ethyl, methyl, and n-butyl)

Filter GFF-T10 Glutaraldehyde

Filter GFF-T11 Isocyanates (monomers only)

Filter GFF / polyester-T18 Phosphine

Filter GFF-T21 Ozone

Filter MCE Mixed cellulose ester filter (37 mm)

Glass Fiber Filter (13 mm) in Swinnex cassette

GFF, treated with sulfuric acid (SKC 225-9004)

GFF, treated with mercuric acetate for mercaptans (store cold) (SKC 225-9007)

GFF treated with DNPH for glutaraldehyde. Two filters contained in

one cassette. Store cold (SKC 225-9003)

GFF treated with 1-(2-pyridyl) piperazine. Store cold. (SKC 225-9002)

GFF treated with mercuric chloride. Store cold

GFF treated with nitrite (SKC 226-9014) (Special-order item due to 28-day shelf

life. Store cold.)

Metals; hydroquinone; particulateFluoride

Filter MCE-25mm Fibers; asbestos

Filter MCE / Cellulose pad-T9 Fluorides (gaseous and particulate)

Filter MCE / Treated pad-T20 SOx (Sulfur dioxide; sulfate; sulfite)

Filter PTFE (0.45 µm) Teflon Filter (0.45 µm pore size, 25 mm) Hydrogen sulfide (prefilter)

Filter PTFE-1 µm Teflon Filter (1 µm pore size; 37 mm) Alkaline dust

Filter PTFE-2 µm PNAs; metal-working fluids; oil mist

Filter PVC Polyvinyl Chloride (5-µm pore size) Crystalline silica; hexavalent chromium

Filter PVC–PW

Filter Quartz (precleaned) Diesel particulate; elemental carbon

Filter Silver filter-cleaned Silver membrane (25 mm) Chlorine

Mixed cellulose ester filter (25 mm), with black cowl

MCE and backup pad (cellulose) treated with sodium carbonate (SKC 225-9001)

MCE and backup pad (cellulose) treated with sodium carbonate and support (SKC

225-9005)

Teflon Filter (2 µm pore size; 37 mm) Order precleaned for MWF/oil mist.

Polyvinyl Chloride (5-µm pore size) – preweighed

Particulate (also, particulate on same filter as

metals or silica)

Quartz-baked - 37 mm. Also, see SKC DPM if sampling in a mine.

Filter SKC DPM Diesel particulate; elemental carbon

Sorbent Tubes Anasorb 708 Anasorb 708 (SKC 226-30-08)

Sorbent Tubes Anasorb 747 Methyl ethyl ketone

Sorbent Tubes Anasorb 747-T8 Ethylene oxide (ETO)

Sorbent Tubes Anasorb CMS Methylene chloride

Sorbent Tubes Carbon bead-T Iodine; sulfur dioxide

Sorbent Tubes Carbotrap Volatiles scan by GC/MS

Sorbent Tubes Chrm 106 Nitromethane

Sorbent Tubes CT Charcoal tube, 150-mg (SKC 226-01) Organic solvents

Sorbent Tubes CT (600 mg) Charcoal tube, 600-mg (SKC 226-09)

SKC’s special filter for diesel particulate (used by MSHA and for mine monitoring)

Acrylic or methacrylic acid(need 2 tubes per sample)

Carbon bead (SKC 226-81A or ORBO 90)

Carbon bead, treated with hydrobromic acid. Store cold. (SKC 226-178)

Anasorb CMS, carbon-type sorbent (SKC 226-121)

Anasorb 747 treated with potassium hydroxide (SKC 226-80)

3-stage tube, made by Supelco. Requires cleaning at the lab, and should be used

within 30 days of cleaning.

Chromasorb 106 (SKC 226-110 or 226-111A) (Lab needs time to order; not a

routine stock item)

Organic solvents (has greater capacity,but higher LOD, than 150-mg tube)

Sorbent Tubes CT (2) / (226-37) Anasorb CSC (SKC 226-37) 1,3-Butadiene

Sorbent Tubes CT-T4 1,3-Butadiene; 2-ethylhexyl acrylate

Sorbent Tubes Drierite Drying tube (SKC 226-44) Carbon disulfide

Sorbent Tubes Florisil Florisil (SKC 226-39 or ORBO 60) Polychlorinated biphenyls (PCBs)

Sorbent Tubes Hopcalite Mercury

Sorbent Tubes Mol. Sieve-T15 Nitrogen dioxide (NO2)

Sorbent Tubes Mol. Sieve Set-T15 Nitrogen oxides (NO/NO2)

Sorbent Tubes ORBO 34 Charcoal tube from Supelco Hydrogen sulfide

Sorbent Tubes ORBO 90 or 92 Methylene chloride; vinyl acetate

Sorbent Tubes ORBO 91 Butane; propane

CT treated with 4-t-buyl catechol (SKC 226-73 or ORBO 351)

Anasorb C300, SKC’s equivalent to Hopcalite/hydrar (SKC 226-17-1A)

Molecular sieve (SKC 226-40-02). Store cold.

Molecular sieve set (SKC 226-40). Set of 3 tubes. Store cold. See SKC instructions

for sampling train.

Supelco Carboxen 564 (equivalent to SKC 226-81A)

Supelco Carbosieve S-III (equivalent to former SKC 226-121)

Sorbent Tubes OVS-2 Pesticides (organophosphorus)

Sorbent Tubes OVS-7 Glycols

Sorbent Tubes OVS-Tenax Phthalates

Sorbent Tubes Porapak P Porapak P sorbent (SKC 226-114) Dimethyl sulfate

Sorbent Tubes Porapak Q Porapak Q sorbent (SKC 226-115) Furfuryl alcohol

Sorbent Tubes PUF Chlorinated pesticides; PCBs

Sorbent Tubes SG Aliphatic amines; Methanol

Sorbent Tubes SG-T2 Aldehydes (done by HPLC)

Sorbent Tubes SG-T3 Ammonia

Sorbent Tubes SG-T12 Acid mist

XAD-2 with 13mm glass fiber filter, in one tube (SKC 226-30-16)

XAD-7 with 13mm glass fiber filter, in one tube (SKC 226-57)

Tenax with 13mm glass fiber filter (SKC 226-56)

Polyurethane foam (client needs to order directly from SKC or Supelco)

Silica gel tube-225-mg (SKC 226-10) or 775 mg (SKC 226-15)

SG treated with DNPH (SKC 226-119) (store cold)

SG treated with sulfuric acid (SKC 226-10-06)

SG, water-washed (SKC 226-10-03 or ORBO 53)

Sorbent Tubes SG-T19 Hydrazoic acid

Sorbent Tubes SG – washed & baked

Sorbent Tubes Soda Lime tube Soda lime (SKC 226-28) Hydrogen cyanide (HCN)

Sorbent Tubes Tenax (30 mg) Biphenyl

Sorbent Tubes Tenax (150 mg) Tenax (SKC 226-35-03) Phosphorus (vapor)

Sorbent Tubes XAD-2

Sorbent Tubes XAD2-T1

Sorbent Tubes XAD2-T5 Amines done by HPLC

Sorbent Tubes XAD2-T14 Maleic anhydride

Sorbent Tubes XAD-4 XAD-4 sorbent (SKC 226-93) Nicotine

SG treated with sodium hydroxide. Store cold. (SKC 226-55)

SG, cleaned and dried. (SKC 226-183: set of 2 tubes)

Tenax (SKC 226-35-01). Not a routine stock item; need time to order.

XAD-2 sorbent-150 mg (SKC 226-30-04 or ORBO 43)

Polynuclear Aromatic Hydrocarbons (PAHs); nicotine

XAD-2 treated with 2-hydroxymethyl piperidine. Store cold. (SKC 226-117 or

ORBO 24 for TWA; SKC 226-54 for STEL)

Acrolein; acetaldehyde; formaldehyde (STEL tube for formaldehyde, only)

XAD-2 treated with 1-naphthylisothiocyanate (SKC 226-30-18)

XAD-2 treated with p-anisidine (SKC 226-30-07) (store cold)

Sorbent Tubes XAD-7 XAD-7 sorbent (SKC 226-95) Cresols; phenol

Sorbent Tubes XAD7-T7

Sorbent Tubes XAD7-T16 (w/GFF disc) Pentachlorophenol

Impinger Solu.on 0.1N H2SO4 Sulfuric acid Ammonia

Impinger Solu.on 0.1N KOH Potassium hydroxide Cyanide

Impinger Solu.on 0.1N NaOH Sodium hydroxide (0.1N) Cyanide

Impinger Solu.on 0.1% Sulfamic acid Sulfamic acid Chlorine

Impinger Solu.on 80% IPA / 3%H2O2

Impinger Solu.on NaHSO3 Sodium bisulfite, 1% Formaldehyde

Impinger Solu.on Nitroreagent N-(4-nitrobenzyl)-propylamine in toluene

XAD-7 treated with phosphoric acid (SKC 226-98)

Triethylamine; trimethylamine; 2-ethylcyanoacrylate

XAD-7 that is methanol-washed (SKC 226-97) w/GFF disc. Set of 3 tubes.

Ispopropyl alcohol and hydrogen peroxide

Sulfur dioxide or sulfuric acid (stack sampling)

Isocyanates (especially polyisocyanates) using the Bayer method 1.4.4

Impinger Solu.on Pip/Tol Soln.

Impinger Solu.on TiOSO4 Titanium oxysulfate Hydrogen peroxide

Passive Badges 3M 3500 OVM Single pad of charcoal Organic solvents

Passive Badges 3M 3520 Two pads of charcoal

Passive Badges 3M 3551 Badge for ethylene oxide (ETO) Ethylene oxide

Passive Badges 3M 3721 Badge for formaldehyde Formaldehyde by general chemistry

Passive Badges SKC 575-001 Charcoal, 350 mg Organic solvents

Passive Badges SKC 575-002 Anasorb 747, 500 mg Organic solvents

Passive Badges SKC Mercury Mercury

Passive Badges SKC Mercury Sorbent capsule (one-time use) Mercury

1-(2-methoxyphenyl) piperazine in toluene

Isocyanates (monomers andpolyisocyanates)

Organic solvents, where extra capacity isneeded or for compounds prone tobreakthrough; especially acetone

acetonitrile, ethyl ether, freons, and IPA

Capsule holder (reusable for mercury) – Must order from SKC

Passive Badges SKC UMEx 100 Formaldehyde by HPLC

Passive Badges Assay Tech OVM Charcoal badge #566 (replaces #541) Organic solvents

Passive Badges Assay Tech (HCOH) Aldehydes by HPLC

Tape, impregnated with DNPH. Store cold. Analyzed by HPLC.

DNPH-treated badge #571. Store cold. Analyzed by HPLC.

Abbreviation Full Name

GC/ECD Gas chromatography/Electron Capture Detector

GC/FID Gas chromatography/Flame Ionization Detector

GC/FPD Gas chromatography/Flame Photometric Detector

GC/MS Gas chromatography/Mass Spectrometry

GC/NPD Gas chromatography/Nitrogen-Phosphorus Detector

Gravimetric Weight

HPLC High Performance Liquid Chromatography

IC Ion Chromatography

ICP Inductively Coupled Argon Plasma Spectroscopy (also called ICAP)

ICP/MS ICP with Mass Spectrometry

IR Infra-Red

PCM Phase Contrast Microscopy

PLM Polarized Light Microscopy

SEM Scanning Electron Microscopy

TEM Transmission Electron Microscopy

Thermal-optical Thermal-optical detector

Wet Chem Includes colorimetric, titrimetric, ion-specific electrode, and visible spectrometry analyses

XRD X-Ray Diffraction

CFU Colony-forming units

cm Centimeter

COC Chain-of-Custody form (also called laboratory request form)

FGB Fritted Glass Bubbler

f/mm2 Fibers per square millimeter

g Gram

hrs Hours

in Inch

L Liter

LOD Limit of detection (also ―reporting limit")

Lpm Liters per minute

M Molarity

m Meter

m3 Cubic meter

mg Milligram

mL Milliliter

N Normality

N/A Not applicable

ng Nanogram

No. Number

Imp Impinger

mm Millimeter

pc. Piece

ppm Parts-per-million

prep Preparation

RL Reporting limit

STEL Short-term exposure limit

T Treated media (used for sampling media descriptions)

TAT Turnaround time

TWA Time-weighted average

µg Microgram

µm Micron

w/ With

wks Weeks