Ancon 12pp Ce Booklet

Embed Size (px)

Citation preview

  • 7/25/2019 Ancon 12pp Ce Booklet

    1/12

    1

    At Ancon, its all part of the service

  • 7/25/2019 Ancon 12pp Ce Booklet

    2/12

    CE Marking

    to the CPR:What does it all mean?

  • 7/25/2019 Ancon 12pp Ce Booklet

    3/12

    With effect from 1st July 2013, under

    the new Construction Products

    Regulation (CPR), virtually all

    construction products must carry

    the CE mark before they can legally

    be sold in Europe.

    There are various exceptions. Many new

    or innovative products, for instance, fall

    outside the scope of current European

    Standards/Technical Approvals and

    therefore cannot be CE marked.Where it is applied, CE marking makes it

    easy for specifiers, distributors and end

    users across Europe to see immediately

    that a product has a standard technical

    specification and, as the information

    and layout is standardised too, it helps

    simplify comparisons between products

    manufactured in different countries,encouraging trade.

    The CE mark is applied either directly

    to a product, its packaging or to its

    accompanying documentation.

    CE marking, however, does not replace

    local Building Regulations. Users in

    the UK still need to ensure that a

    product complies with any local market

    requirements. For example, in addition

    to declaring performance in tension

    and compression to the European

    Standard EN 845 Part 1, cavity wall tiesin England and Wales should also meet

    the acoustic requirements of Approved

    Document E: Resistance to the passage

    of sound.

    Did you know?CE is an abbreviation of the French, ConformitEuropenne, meaning European Conformity.

    CE marking is a method of identifying those products thatcomply with a harmonised European Standard or have aEuropean Technical Approval.

    What do we mean by CE Marking?

    3

  • 7/25/2019 Ancon 12pp Ce Booklet

    4/12

    Under the new Construction Products

    Regulation, it is mandatory to apply the

    mark to a construction product covered

    by a harmonised European Standard

    or when it conforms to a European

    Technical Assessment that has been

    issued for it.

    To qualify for a CE mark, manufacturers

    must undertake several tasks. These

    are specific to each product type and

    are given in the Standard.Tasks include:

    Testing of each product type

    Ensuring the necessary factory

    production controls are in place

    to guarantee consistency

    Publishing a signed Declaration of

    Performance (DoP) for each product

    Issuing the CE mark with the

    product, accompanied by any

    essential additional information

    In some cases, the tasks must be

    undertaken by an approved external

    body, rather than the manufacturer.

    The Declaration of Performance, also

    referred to as an EC Declaration of

    Conformity by many current European

    Standards, must be readily available

    and translated into the language of

    the country in which the product is

    supplied. A hard copy must be

    available on request.

    Once the DoP has been completed,

    and the CE mark applied, the

    manufacturer has a legal responsibilityto ensure the product continues to

    conform to the Standard.

    Failure to CE mark a product

    where required, or to ensure ongoing

    conformity, leaves a manufacturer open

    to legal action. Products concerned can

    be removed from sale by enforcement

    agencies e.g. Trading Standards inthe UK.

    How does CE Marking work?

    CE marking is not new it has been compulsory for a widerange of everyday products for many years for instance,toys, machinery and electrical items.

    4

  • 7/25/2019 Ancon 12pp Ce Booklet

    5/12

    Masonry supports Windposts Compression

    systems Steel balcony

    connectors Other fabricated

    components

    EN 1090. Part 1.Execution of steel structuresand aluminium structures.Requirements for conformityassessment of structuralcomponents.

    Designs to EN 1993(Eurocode 3).

    Inspection offactory productioncontrols by anapproved bodyincluding welding

    certification*

    Cavity wall ties Frame cramps Movement ties Head restraints Channel ties Stone fixings

    EN 845. Part 1.Specification for ancillarycomponents for masonry:

    Ties, tension straps,hangars and brackets.

    Extensiveindependentproduct testing.

    Lintels EN 845. Part 2.Lintels. Extensiveindependentproduct testing.

    MasonryreinforcementsAMR, AMR-Xand AMR-CJ

    EN 845. Part 3.Bed joint reinforcement of

    steel meshwork.

    Extensiveindependentproduct testing.

    Ancon 500Tension barsystems

    ETA 06/0146 Product testing andaudited productioncontrols.

    *Ancon is certified to undertake welded fabrication work to Execution Class 2 to EN 1090-2. This covers the

    majority of building applications and is the default class when unspecified. For more information on Execution

    Classes, please visit www.ancon.co.uk or contact Ancon.

    Ancon products thatcarry the CE mark

    Ancon Product(s) Relevant European Key Requirements Standard/Approval of CE Marking

    5

    Legal requirement:

    111 JJJuuulllyyy 222000111444

    Legal requirement:

    111 JJJuuulllyyy 222000111333

    Legal requirement:

    111 JJJuuulllyyy 222000111333

    Legal requirement:111 JJJuuulllyyy 222000111333

    Legal requirement:

    111 JJJuuulllyyy 222000111333

  • 7/25/2019 Ancon 12pp Ce Booklet

    6/12

    To prepare for its adoption in the UK

    and Ireland, where we sell a slightly

    different portfolio of products, we

    successfully carried out extensive

    independent product testing, passed

    external audits of our manufacturing

    facilities, published the necessary

    collection of Declarations (DoPs)

    and have applied the CE mark to

    all affected Ancon products.

    Employees from across the business,

    in purchasing, production, engineering,

    marketing and sales, worked together

    to meet the CE marking deadline, and

    have ensured all necessary working

    practices, procedures and skills are

    in place to achieve and maintain

    compliance with all aspects of the

    Construction Products Regulations.

    Since 1st July 2013, all Ancon

    products have carried a CE markwhere required.

    What Ancon has done toensure CE Marking compliance

    As a leading manufacturer of steel construction products, withestablished sales throughout Europe, Ancon has been workingwith CE Marking legislation for many years. In fact, it has beenmandatory in many of our key European markets for some time.

    CE mark and additional

    essential information

    Issued on the product, packaging or

    with associated documentation.

    6

  • 7/25/2019 Ancon 12pp Ce Booklet

    7/12

    Supporting documentation

    Declaration of Performance (DoP)

    available for each product.

    Certification documents

    Factory production control certificatesfrom an approved third party includingwelding certification.

    Declaration of Performance

    Manufactured by:

    Ancon Building ProductsPresident WayPresident ParkSheffield S4 7URUnited Kingdom

    Tel: +44 (0)114 275 5224Fax: +44 (0)114 276 8543Email: [email protected]: www.ancon.co.ukTwitter: @AnconUK

    ANCON hereby declares that the product range identified as,

    ST1 225mmconforms to the provisions of,

    ZA Annex, EN 845-1: 2003 +A1: 2008

    as a,

    Symmetrical Wall Tie covered in clause 1 of the standard

    Intended Use: Type 1 wall tie for connecting two leaves of a cavity

    wall. Suitable for 76-100mm cavities.

    Notified Body: CERAM Research Limited

    Queens Road, Penkhull

    STOKE-ON-TRENT ST4 7LQ

    United Kingdom

    Tel: +44 (0)1782 764444

    Notified Body Number: 1289

    This product conforms to System 3 - Assessment and Verification of Constancy of

    Performance. All necessary testing was conducted at the above notified body.

    Essential Characteristics

    Compressive Load Capacity: 4600N (M2 (iv) Mortar), 5640N (M12 (i) Mortar)

    Tensile Load Capacity: 4060N (M2 (iv) Mortar), 5490N (M12 (i) Mortar)

    Water Shedding Capability: Resistant

    Durability: Material/coating reference 3, Steel grade 1.4301

    Dangerous Substances: None

    Conditions

    Embedment Depth: min. 62.5mm

    Minimum Mortar Joint Width: 10mm

    Recommended Spacing: Refer to Clause 6.2.2.2. PD 6697:2010

    Declaration Number: A0017-00-EN

    Authorised by:

    Stuart Maxwell, Managing Director, on 16th May 2013

    Declaration of Performance

    Manufactured by:

    Ancon Building ProductsPresident WayPresident ParkSheffield S4 7URUnited Kingdom

    Tel: +44 (0)114 275 5224Fax: +44 (0)114 276 8543Email: [email protected]: www.ancon.co.ukTwitter: @AnconUK

    ANCON hereby declares that the product range identified as,

    IHR-B/ IHR-V/ IHR-Sconforms to the provisions of,

    ZA Annex, EN 845-1: 2003 +A1: 2008

    as an,

    Internal Head Restraint covered in clause 1 of the standard

    Intended Use: Internal head restraint for connecting the top of a

    new masonry wall to the underside of a structural

    frame - max. 25mm gap

    Notified Body: CERAM Research Limited

    Queens Road, Penkhull

    STOKE-ON-TRENT ST4 7LQ

    United Kingdom

    Tel: +44 (0)1782 764444

    Notified Body Number: 1289

    This product conforms to System 3 - Assessment and Verification of Constancy of

    Performance. All necessary testing was conducted at the above notified body.

    Essential CharacteristicsShear Load Capacity: 4760N

    Durability: Material/coating reference 3, Steel grade 1.4301

    Dangerous Substances: None

    Conditions

    Minimum Mortar Class: N/A

    Minimum Mortar Joint Width: 10mm

    Recommended Spacing: As required

    Declaration Number: A0090-00-EN

    Authorised by:

    Stuart Maxwell, Managing Director, on 16th May 2013

    Declaration of Performance

    Manufactured by:

    Ancon Building ProductsPresident WayPresident ParkSheffield S4 7URUnited Kingdom

    Tel: +44 (0)114 275 5224Fax: +44 (0)114 276 8543Email: [email protected]: www.ancon.co.ukTwitter: @AnconUK

    ANCON hereby declares that the product identified as

    AMR/S/D5.0/W60

    conforms to the provisions of Annex ZA, BS EN 845-3:2003+A1:2008, as

    Bed Joint Reinforcement defined in 4.2.2 of the Standard

    Intended Use: For structural uses in walls and partitions

    Notified Body: CERAM Research Limited

    Queens Road, Penkhull

    STOKE-ON-TRENT ST4 7LQ

    United Kingdom

    Tel: +44 (0)1782 764444

    Notified Body Number: 1289

    This product conforms to System 3 - Assessment and Verification of Constancy of

    Performance. All necessary testing was conducted at the above notified body.

    Product Dimensions, Performance and Durability

    Length: 2700 1.5%

    Width: 60 5mm

    Profile Height: 2.9 0.4mm

    Longitudinal Wire Size: 7.35 0.1mm

    Cross Wire Size: 2.30 0.1mm

    Pitch of Cross Wires: 450 3.0%

    Characteristic Yield Strength of Longitudinal Wires: 500N/mm2

    Characteristic Yield Strength of Cross Wires: 500N/mm2

    Bond Strength: 21150N

    Lap Length: 225mm (to include at

    least one cross wire)

    Shear Load Capacity of Welds: 2000N

    Ductility: Normal

    Durability - Material/Coating Reference: R3(Stainless Steel)

    Dangerous Substances: None

    Declaration Number: A0204-00-EN

    Authorised by:

    Stuart Maxwell, Managing Director, on 1st May 2013

    7

  • 7/25/2019 Ancon 12pp Ce Booklet

    8/12

    Q: I am a distributor, does CE Marking affect me?A: You need to be sure that all of the construction products you sell meet

    the requirements of the CPR and carry the CE mark where appropriate.

    You also need to ensure products are accompanied by the correct

    documentation and that relevant additional information is supplied

    when requested.

    Ancon distributors can be confident that all of our products meet the CPR

    requirements and are CE marked where appropriate. You can download

    any Declaration of Performance (DoP) and other relevant information from

    www.ancon.co.uk/CE.

    Q: I am a distributor, what about old stock which does not carrya CE mark?

    A: Only construction products manufactured after 1st July 2013 are affected.Stock supplied before this date is unaffected.

    Q: I am a contractor, CE Marking doesnt affect me, does it?A: You need to be satisfied that the products you use meet the requirements

    of the CPR, as well as meeting the performance criteria for the project

    involved. The project engineers specification should take all this into

    account. You should also be aware that if you modify a CE marked

    product in any way that may affect the DoP, you effectively become

    the manufacturer. You must therefore carry out any necessary testing,draw up your own Declaration of Performance and ensure continuing

    compliance with the Regulation.

    All Ancon products are CE marked where required and we offer free

    technical support on product suitability. Our DoPs are available from

    www.ancon.co.uk/CE. Some Ancon products can be modified on site

    to our instructions, without affecting the validity of the CE mark e.g.

    AnconOptima masonry support.

    Your CE Markingquestions answered

    8

  • 7/25/2019 Ancon 12pp Ce Booklet

    9/12

    Q: I am an engineer, do I need to make any changesto how I specify products?

    A: Product specifications should be amended to include CE marked itemsonly, where the product is covered by a harmonised European Standard

    e.g. masonry support systems, windposts, wall ties and bed joint

    reinforcement. A list of harmonised standards is available from NANDO

    http://ec.europa.eu/enterprise/newapproach/nando/

    By specifying Ancon, engineers are guaranteed CE marked products,

    backed by Eurocode designs. Ancon provides technical advice and

    specification assistance.

    Q: What about Ancon products that are not currentlycovered by a harmonised European standard (hEN)

    or ETA can I still specify, sell or use them?

    A: Yes, this is completely acceptable. Ancon holds a number of voluntary, third party approvals for its products

    (see page 10). These have similar or sometimes even greater compliance

    requirements than CE marking.

    We are continuing to monitor the position with regards to new European

    Standards, and will publish any changes at www.ancon.co.uk.

    9

  • 7/25/2019 Ancon 12pp Ce Booklet

    10/12

    Ancon products excluded fromCE Marking legislation

    Punching ShearReinforcement Shearfix

    Reinforcing Bar Couplers MBT/TT/Bartec

    Reinforcement ContinuitySystems Eazistrip/KSN

    Balcony ConnectorsIsolan

    Shear Load ConnectorsDSD/HLD/LockableDowel

    Wall StartersUniversal/Quickstart

    Wall TiesTeploTie

    Cast-in Channels withCrimped Anchor Pairs

    Warm Roof Helical Fixings

    These products are outside the scope of CE marking, however mostcarry a voluntary mark from a recognised third party to provideassurance of product testing and/or manufacturing controls.

    Tested at

    EMPA

    Tested at

    CERAM

    Tested to BS 5080,Parts 1 & 2

    10

  • 7/25/2019 Ancon 12pp Ce Booklet

    11/12

  • 7/25/2019 Ancon 12pp Ce Booklet

    12/12

    Ancon Building ProductsPresident Way

    President Park

    Sheffield

    S4 7UR

    Tel: +44(0)114 275 5224Fax: +44(0)114 276 8543

    Email: [email protected]

    Follow: @AnconUK

    www.ancon.co.uk

    First published June 2013Updated October 2013