18
Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit

Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

Anderson Dam Annual EAP Orientation Nina Merrill

Program Administrator Dam Safety Program Unit

Page 2: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Anderson Dam

  Year Constructed: 1950

  Dam Height: 240 feet

  Crest Length: 1,400 feet

  Crest Width: 40 feet

  Reservoir Capacity: 89,073 acre-feet (currently restricted to 61,810 acre-feet)

Page 3: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Federal Energy Regulatory Commission (FERC) Requirements

  The District is required by FERC to reprint the

Emergency Action Plan (EAP) binder every 5 years

  Annual face-to-face orientations to familiarize with EAP contents

Page 4: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

EAP Binder

  The Anderson Dam EAP binder is intended to be a living document

  As information gets outdated, District will send Emergency Management Agencies updates for specific pages or sections

  We need your help in notifying the District of personnel or contact information changes

Page 5: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Contact  informa,on

Direc,ons  to  water  district  staff  &  communica,ons  in  general  

Inunda,on  Maps  

Review of Critical EAP Features

Page 6: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Condition A – Imminent or Actual Failure

Condition defined as “where failure

either has occurred, is occurring, or

obviously is about to occur.”

Page 7: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Notification Lists – Condition A

Page 8: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Condition B – Potential Failure

Condition defined as “where a failure

may eventually occur, but pre-

planned actions taken during certain

events may moderate or alleviate

failure.”

Page 9: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Notification Lists – Condition B

Page 10: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

EOC Staff Directory – Pink Sheets

Page 11: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Post-Earthquake Dam Inspection Program – Staff Directory

Page 12: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Post Earthquake Dam Assessment Program (PEDAP)

  After an earthquake felt by the inspector for 10 seconds or more

  After an earthquake with reported magnitude 5.0 or greater within 20 miles of District Dam

Page 13: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

District PEDAP Team Inspection Checklist

  Dam Crest and Face

  Evidence of slumps, depressions, cracks, deformities, etc.

  Dam Outlet Pipe

  Changes in flow and turbidity

  Spillway

  Evidence of cracks or distortion

  Weir   Changes in seepage

Page 14: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

2009 Inundation Study

Page 15: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Inundation Maps

Page 16: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Inundation Maps

Page 17: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

|

Inundation Maps

Page 18: Anderson Dam Annual EAP Orientation - Santa Clara County ...€¦ · Anderson Dam Annual EAP Orientation Nina Merrill Program Administrator Dam Safety Program Unit | Anderson Dam

QUESTIONS