2
©Toshiba Medical Systems Corporation 2014. All rights reserved. Design and specifications subject to change without notice. MCAXR0258EAA 2014-11 TME/D http://www.toshibamedicalsystems.com Printed in Japan Toshiba Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485. Toshiba Medical Systems Corporation Nasu Operations meets the Environmental Management System standard ISO 14001. Aquilion, Aquilion ONE are trademarks of Toshiba Medical Systems Corporation. Angio CT Suite Line up Aquilion LB Typical Layout Aquilion PRIME Aquilion ONE 2,000 8,500 Center of the table 5,300 Center of the table 3,400 Computer room Angiography room Control room 6,500 2,300 Angio CT Suite Same-room installation

Angio CT Suite - seijiroyazawaiwai.com · 8/6/2016  · Angio CT same-room installation provides the ˛exible workspace required for a variety of procedures. When both the C-arm and

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

  • ©Toshiba Medical Systems Corporation 2014. All rights reserved.Design and speci�cations subject to change without notice.MCAXR0258EAA 2014-11 TME/D

    http://www.toshibamedicalsystems.com

    Printed in Japan

    Toshiba Medical Systems Corporation meets internationally recognized standards for Quality Management System ISO 9001, ISO 13485.

    Toshiba Medical Systems Corporation Nasu Operations meets the Environmental Management System standard ISO 14001.

    Aquilion, Aquilion ONE are trademarks of Toshiba Medical Systems Corporation.

    Angio CT Suite

    Line up

    Aquilion LB

    Typical Layout

    Aquilion PRIME Aquilion ONE

    2,000 8,500Center of the table 5,300

    Cent

    er o

    f the

    tabl

    e 3

    ,400

    Computer room

    Angiography room

    Control room

    6,5

    00 2

    ,300

    Angio CT SuiteSame-room installation

  • Work more e�ciently and e�ectively.

    High-level integration of an angiography system and a CT system

    creates new potential for medical sites.

    Self-propelled helical CT scanner

    Ceiling-suspended C-arm

    The wide operating range of the self-propelled CT gantry and the C-arm provides �exible system positioning for angiography and CT scanning, allowing helical scanning to be performed without moving the patient. Since the same table is used for both angiography and CT scanning, patient positioning can be performed easily during sequential angiography and CT scanning procedures.

    The rails for the self-propelled CT gantry are �ush with the �oor. The level �oor and rail surface allows peripheral devices such as ultrasound systems to be moved smoothly over the rails.

    The monitor suspension can be set on either side of the table. This enables �exible spatial arrangement and allows medical sta� to work in the optimum position for the procedure.

    Angio CT same-room installation provides the �exible workspace required for a variety of procedures.

    When both the C-arm and CT gantry are at the park position

    Abundant workspace is ensured.

    The tabletop is moved, allowing quick switching between the angiography and CT system.

    Angiography

    When the CT gantry is set to the park position, there is no interference with operation of the angiography system.

    CT scan

    When the C-arm is set to the park position, there is no interference with CT scanning.

    Efficient workflow Non-protruding rails Flexible spatial arrangement

    Mo

    re e

    �c

    ien

    t an

    d e

    �e

    ctiv

    e a

    t wo

    rk.Switching between Angio and CT

    Angio CT SuiteSame-room installation